Вы находитесь на странице: 1из 19

Andhra Pradesh State FiberNet Limited (APSFL)

Empanelment of Service Providers for Last mile Optical Fiber Connectivity(4F & 24F)
for Government offices from the PoPs of AP Fibre Grid (on rate contract)
Tender No: APSFL/ Last Mile SP-1/102/2016 Dt: 12/08/2016
Pre-Bid Meeting Held on 19/08/2016 at 3:00 P.M
Corrigendum-2 dated 24/08/2016
Bidders may please note that this Corrigendum document is part of the tender.
Bidders are requested to sign and seal the copy of the Corrigendum by the
Authorised signatory of the Tender and submit it along with the RFP.
S.No

Section
in the
Tender

Page
No.

Clause in RFP

Revised Clause

9. Sealed tender may be


submitted not later than 2608-2016 @ 3:00 PM at the
address mentioned in (1).

tender may be
Sealed
submitted not later than 0309-2016 @ 3:00 PM at the
address mentioned in (1).

10. Technical proposal will


be opened on 26-08-2016 @
4.00 PM at the address
mentioned in (1).

Technical proposal will be


opened on 03-09-2016 @
4.00 PM at the address
mentioned in (1).

27

8.1 Fiber Specifications

Annexure-I

New
Clause

Annexure
IV
Checklist

13

8. Technical Compliance Letter from OEM along with


leaflets/data
sheets/certifications if any
for
the
fibre/accessories/fittings etc

List of Accessories
Annexure-II
8. Technical Compliance Letter from OEM along with
leaflets, data sheets, ISO 9001
certificate, TL9000 certificate
and
if
any
for
the
fibre/accessories/fittings etc.

New
Clause

AnnexureVIII-Price
Bid form

19-20

New
Clause

The day-1 of the work starts


after 2 weeks from the date of
issue of the Purchase order.
Annexure-III

The bidders will be ranked


based on the rate quoted
against item of scheduled A.

Wherever necessary, the


agencies have to pull 2 core
fiber as per the rates
approved by APSFL.
i.e Rs.16,980/- per Km
(including all the taxes) &
Splitters 1:2 Rs.3,766/1:4 Rs.4,073/1:8- Rs.4,674/1:16- Rs.6,736/-

Annexure-I
Cable Specifications 4F G65D 2 Unitube ADSS Drop Cable
CABLE CONSTRUCTION DIAGRAM (Wind Speed : 65 Kmph, Span Length : 65m)

INSTALLATION & OPERATION CONDITION

S. No.

Parameter

Unit

4F ADSS OFC

Span Length of Cable

Upto 65

Ice Load on the cable

Kg/m

Operational wind velocity

KmpH

65

Installation Sag

1.0

Operational Sag

2.0

Cable Tensile Strength

550 @ 0.25% fiber strain

CABLE CONSTRUCTION DETAILS


1

Fiber Per Loose Tube

No

No of Loose Tube

No

Water Blocking Material for loose Tube

Loose Tube Inner Diameter (Nominal)

mm

1.4

Loose Tube Outer Diameter (Nominal)

mm

2.0

Color of Fiber

Blue, Orange, Green, Brown.

Color of Loose Tube

White / Any.

FRP Size (Nominal)

mm

FRP Numbers

Nos

10

Aramid Quantity (Nominal)

Kg/Km

1.5

11

Outer Sheath Thickness (Nominal)

mm

12

Outer Sheath Color

1.8
Black with Two Yellow
coloured Strips

13

Cable diameter

mm

6.0 0.3

14

Cable Weight

Kg/Km

30 4

15

Cable Printing Color

Filling Jelly - Thixotropic

White

CABLE OPTICAL PARAMETERS


1
2
3

Fibre Type
Maximum Cabled attenuation at 1310 nm
Maximum Cabled attenuation at 1550 nm

dB/Km
dB/Km

G652 D
0.35
0.21

Maximum Cabled attenuation at 1625 nm

dB/Km

0.23

ps/km

PMD cabled fibre

0.1

Fiber Specifications for 24 core ADSS cable


S. No.

Description

Fiber used should be complying as per ITU-T G.652 D.

Fiber Geometrical Parameters

2 (a)

MFD at 1310 nm

9.2 +/- 0.4 m

2 (b)

MFD at 1550 nm

10.4 +/- 0.5 m

Core Diameter (Typical) -

8.6 m

Cladding Diameter -

125 +/- 1.0 m

2I
2 (d)
2I

Cladding Non-Circularity - 1 %

2 (f)

Core Clad concentricity error 0.6 m

2 (g)

Diameter over primary coated with double UV cured acrylate 245 m 10 m

2 (h)

Coating / Cladding Concentricity < 12

Fiber Optical/Transmission Properties

3 (a)

Maximum Attenuation (Fiber) at 1310 nm < 0.34 dB/Km

3 (b)

Maximum Attenuation (Fiber) at 1490 nm < 0.24 dB/Km

3I

Maximum Attenuation (Fiber) at 1550 nm < 0.21 dB/Km

3 (d)

Maximum Attenuation (Fiber) at 1625 nm < 0.24 dB/Km


Maximum Attenuation (Fiber) between 1380-1390 nm < Attenuation at 1310 nm

3I
(After Hydrogen Ageing)
3 (f)

Maximum Attenuation (Cabled Fiber) at 1310 nm < 0.34 dB/Km

3 (g)

Maximum Attenuation (Cabled Fiber) at 1490 nm < 0.24 dB/Km

3 (f)

Maximum Attenuation (Cabled Fiber) at 1550 nm < 0.21 dB/Km

3 (g)

Maximum Attenuation (Cabled Fiber) at 1625 nm < 0.24 dB/Km

3 (h)

Chromatic Dispersion (1285-1330)nm 3.5

3 (i)

Chromatic Dispersion (1270-1340)nm 5.3

3 (j)

Chromatic Dispersion at 1550nm

17.5

3(k)

Chromatic Dispersion at 1625nm

22

3 (l)

PMD (1310 nm & 1550 nm)

< 0.3 ps/Km

S. No.

Description

3 (m)

LDV (1310 nm & 1550 nm)

< 0.2 ps/Km

3 (n)

Zero Dispersion Slope

<

3 (o)

Zero dispersion wave length range

3 (p)

Cable cut off - 1260 nm Maximum

0.092 ps/(nm.sq.km)
-

1300 1324 nm

Fiber Reliability Parameters


Proof test strain level -

1%

4 (a)
Test method IEC-60793-1-30
Dynamic Tensile strength (Un-aged) - > 3.8 Gpa
4 (b)
Test method IEC-60793-1-31
Dynamic Tensile strength (Aged)

- > 3.0 Gpa

4I
Test method IEC-60793-1-31
Stripability Force to remove primary coating 1.3 < F < 8.9 N
4 (d)
Test method IEC-60793-1-32
Dynamic Fatigue

>

20

4I
Test method IEC-60793-1-33
Static Fatigue

>

20

4 (f)
Test method IEC-60793-1-33
Fiber Curl

>

4.0 mtrs

4 (g)
Test method IEC-60793-1-34
Macro bend
4 (h)
Test method IEC-60793-1-47 / FOTP 62
Change in Attenuation when fiber is coiled with 100 turns on 30 + 0.1 mm radius
mandrel.
4 (h)(i)

< 0.05 dB/km at 1550 nm


< 0.5 dB/km at 1625 nm
Change in Attenuation when fiber is coiled with 1 turn on 32 + 0.5 mm diameter
mandrel.

4 (h)(ii)

< 0.5 dB/km at 1550 nm


< 1.0 dB/km at 1625 nm

OFC CONSTRUCTION

S. No.

Description

Cross sectional view:

5 (a)

5 (b)

Buffer tube: Four numbers of primary coated colored fibers shall be protected by
loose packaging within a tube which shall be filled with thixotropic jelly.
Color sequence of fibers inside tubes should be Blue, Orange, Green& Brown.

5 (c)

Central Strength Member: Solid FRP non metallic strength member in the center
of the cable core shall be provided.

5 (d)

Cable Core: Primary coated fibers in loose tubes, stranded together around a
central strength member (using reverse lay techniques), shall form the cable core.
Color sequence of loose tubes around FRP should be Blue, Orange, Green, Brown,
Slate& White.

5 (e)

The main cable core containing fibers shall be wrapped by a layer of water swellable tape. Aramid yarn reinforcement shall be done over water swell-able tape to
provide sufficient tensile strength.

5 (f)

A circular and uniform tough weather resistant polyethylene compound


HDPE/MDPE material sheath/Jacket, black in color, (UV Stabilized) shall be
provided over and above the reinforcement of Aramid Yarn. Thickness of outer
sheath should be minimum 1.5 mm.

5 (g)

Two ripcords shall be placed diagonally opposite to each other below the outer
jacket to strip the HDPE outer jacket.

OFC MECHANICAL PARAMETERS


Tensile Strength - 3000 N at maximum allowable 0.25 % Fiber strain

6 (a)
Test Method IEC 60794-1-2-E1
Crush resistance - 2500 N/100 MM X 100 MM
6 (b)
Test Method IEC 60794-1-2-E3

S. No.

Description
Impact Resistance 50 N from 0.5 M

6I
Test Method IEC 60794-1-2-E4
Torsion - +/- 180
6 (d)
Test Method IEC 60794-1-2-E7
Cable Bending Test 20 D, 4 Turns, 10 cycles
6I
Test Method IEC 60794-1-2 E11
Abrasion resistance - Needle 150 gm, Dia 1 mm, Weight 500 gm
6 (f)

No of cycles 100, Duration 1 minute


Test Method IEC-60794-1-2-E2
Repeated Bending - 20D, 35 Cycles

6 (g)
IEC 60794-1-2 E6
Drip Test 30 cm, 70C, 24hr
6 (h)
IEC 60794-1-2-E14
Water Penetration test - 1m head, 3m samples, 24 hrs
6 (i)
IEC 60794-1-2 F5
7

OFC Environmental Parameters

7 (a)

Installation - -10C to + 60C

7 (b)

Operation - - 20C to + 70C

7I

Storage & Transport - -20 to + 70C

Optical Fiber Cable Loading Conditions

8 (a)

Maximum Span length - 70 Meters

8 (b)

Installation Sag - 1.0 %

8I

Operational Sag - 1.5 %

8 (d)

Wind Speed

- 100 Km/hour

8I

Ice loading

- Nil

Optical Fiber Physical Parameters

9 (a)

Cable Diameter - 10.4 +/- 0.5 mm

9 (b)

Cable Weight - 77 +/- 10% kg/km

9(c )

Aramid Quantity (Minimum) 5.5 Kg/Km

S. No.

9 (d)

Description
Printing details : NAME OF MANUFACTURER SM G652 D 24 F ADSS Laser symbol
Year of manufacturer length code Meter Marking
(White Hot Foil Embossing)

9 (e)

Optical Fiber
4 F / Buffer tube
Color - Blue, Orange, Green, Brown
Loose tube

9 (f)

Number 6
Color Sequence Blue, Orange, Green, Brown, Slate, White

9 (g)

Outer Sheath color - Black(Two Yellow Stripe)

9 (h)

Printing details: NAME OF MANUFACTURER SM G652 D 24 F ADSS Laser Symbol


Year of manufacturer Length Code Meter Marking
(White Hot Foil Embossing)

10

Optical Fiber Cable packing details

10 (a)

Cable length in a drum 2/4 +/- 5 % km

10 (b)

Short length - MAX 5 %

10 I

Order Tolerance - +/- 5 %

Annexure II
List of Accessories
A.1

Universal Pole Accessories

Tension Pole Assembly - Should Contain following

Twisted Link
Stay Clamp
Tension Hook
Turn Buckle
Extension Link
Thimble
Terminating Helix
Jumper Cable Clamp
Protective Helix

A.2

Tension Hook:

Dimensions in MM:
L1

L2

L3

177

75

50

12

Note: - Tolerance shall be as per IS:2102


(Detail as per GR, Unless UNTILL Specified)
To be used here C-Bracket is available on pole for fitment of Tension Hook.
HOT DIP GAVANISED as per IS.2629

1
2
3
4
5

Description
Body
Nut
Plain Washer
Spring Washer
Spilt Pin

Material
Alloy Steel Galvanised
Mild Steel Galvanised
Mild Steel Galvanised
Spring Steel Galvanised
Stainless Steel

TENSION HOOK
NOT TO SCALE

A.3

Ref Spec
IS:2004
IS:1363
IS:2016
IS:3063
IS:549

Qty

Unit-MM

TURN BUCKEL:

Dimensions in MM:
L1
L2
170
100

L3
140

D1
18

D2
18

D3
12

Note: - Tolerance shall be as per IS:2102


(Detail as per GR, Unless UNTILL Specified)
MIN Length : 290 MM
MAX Length : 400 MM
Range of ADL : 110 MM
HOT DIP GAVANISED as per IS.2629

1
2
3

Description
Body
Nut Bolt
Nut

Material
Mild Steel Forged Glav
Mild Steel Forged Glav
Mild Steel

Ref Spec
IS:2004
IS:2062
IS:1363

Qty

A.4

Extension Link:

Dimensions in MM:
L1
T1
465
5

W1
14

W2
16

W3
30

D1
16

Note: - Tolerance shall be as per IS:2102


(Detail as per GR, Unless UNTILL Specified)
HOT DIP GAVANISED as per IS.2629

1
2
3
4

Description
Strap
Rivet & Washer
Split Pin
Bolt & Nut M16

A.5

Material
Mild Steel Galvanised
Mild Steel Galvanised
Stainless Steel
Mild Steel Galvanised

Ref Spec
IS:2067
IS:2016
IS:549
IS:1363

Qty

Clevis Thimble:

Dimensions in MM:
L1
L2
L3
102
42
15

T1
4

T2
9

R1
23

R2
15

R3
8

W1
92

W2
40

W3
18

D1
16

Note: - Tolerance shall be as per IS:2102


(Detail as per GR, Unless UNTILL Specified)
FEROUS PARTS ARE HOT DIP GAVANISED as per IS.2629
1
2
3
4

Description
Clamp
Rivet M16 x 45
Washer
Split Pin

CLEVIS THIMBLE
NOT TO SCALE

Material
Aluminium Alloy GDC
Galv Steel
Galv Steel
Stainless Steel
Unit-MM

Ref Spec
IS:617
IS:2016
IS:2016
IS:549

Qty

A.6

Protective Helix (T):

For Example
Dimensions (For Cable Size, D 14.4 MM)
i.
DIA OF EACH WIRE 3.2 0.1
ii.
NO OF SETS 3
iii.
NO OF WIRE PER SET 5
iv.
LENGTH OF HELIX 1000
Dimension details for other cable size shall be indicated by the Manufacturer including the pitch of HELIX.
Note: Ends of RODS shall be deburred Tolerance shall be as per IS:2102
(Detail as per GR, Unless UNTILL Specified)

Description
Protective HElx

A.7

Material
Aluminium Alloy 6061

Ref Spec

Qty

Ref Spec

Qty

Terminating Helix:

Dimensions for Example


L1
1000

T1
2.20.1

D is DIA of each Wire ROD


No. of Wires used 5
Note: Tolerance shall be as per IS:2102
(Detail as per GR, Unless UNTILL Specified)
Dimension details for differe Cable size to be decided AP type Test Approval
For Example Cable Size
Ends of RODA shall be Debur Length of Terminating Helx 1000MM
Terminating Helix to be used with Thimble C DIA 14.4 MM

Description
DEADEHD GRIP

Material
Aluminised Steel

A.8

Jumper Cable Clamp:

Dimensions in MM:
L1
L2
105
65
Dimensions in MM of Insert PAD:
L
40

D1
17.5

D2
5-6

INNER DIA
15

W
35
OUTER DIA
30

Note: Tolerance shall be as per IS:2102


(Detail as per GR, Unless UNTILL Specified)
Insert in TOW HALVES D to suit Cable DIA Ferrous Parts are HOT DIP GALVASIED as per IS:2629
1
2
3

Description
STRAP
Insert
Wing Bolt

A.9

Material
Mild Steel GALY
Polychloradprene Compounded
Mild Steel GALY

Ref Spec
IS:2062

Qty

IS:2062

Pole Mounted Stat Clamp (Tubular):

Dimensions in MM:
Pole Mouted Stay Clamp Tubular
L1
210

L2
20

D1
150

D2
16

T1
5

W
30

Note: - Tolerance shall be as per IS:2102


(Detail as per GR, Unless UNTILL Specified)
HOT DIP GAVANISED as per IS.2629

1
2
3
4

Description
Clamp
Bolt & Nut M16
Rivet 16
Washer

Material
Mild Steel Galvanised
Mild Steel Galvanised
Mild Steel Galvanised
Mild Steel Galvanised

Ref Spec
IS:2062
IS:1363
IS:2016
IS:2016

Qty

Split Pin

A.10

Stainless Steel

IS:549

Pole Mounted Stay Clamp (Rail):

Pole Mounted Stay Clamp (Rail)


L1
L2
L3
L4
270
170
251
151

L5
20

L6
32

L7
50

L8
120

T1
5

T2
20

D1
16

W1
60

Note: - Tolerance shall be as per IS:2102


(Detail as per GR, Unless UNTILL Specified)
HOT DIP GAVANISED as per IS.2629
Description
Clamp
Bolt & Nut M16
Rivet 16
Washer
Split Pin

1
2
3
4
5

A.11

Suspension Pole Assembly:

Should Contain Following

Material
Mild Steel Galvanised
Mild Steel Galvanised
Mild Steel Galvanised
Mild Steel Galvanised
Stainless Steel

Twisted Link
Stay Clamp

Ref Spec
IS:2062
IS:1363
IS:2016
IS:2016
IS:549

Qty

Protective Helix
Suspension Set
Vibration Damper

Suspension Pole Assembly


NOT TO SCALE

A.12

Unit MM

Twisted Eye Link:

Dimensions in MM:
L1
L2
W1
138
100
27
Note: - Tolerance shall be as per IS:2102
(Detail as per GR, Unless UNTILL Specified)
HOT DIP GAVANISED as per IS.2629

Description
Link

A.13

W2
38

Material
Mild Steel

DIA
18

Ref Spec
IS:2062

Qty

Protective Helix (S):

For Example
Dimensions (For Cable Size, D 14.4 MM)
i.
DIA OF EACH WIRE 3.2 0.1
ii.
NO OF SETS 3
iii.
NO OF WIRE PER SET 5
iv.
LENGTH OF HELIX 1400
Dimension details for other cable size shall be indicated by the Manufacturer including the pitch of HELIX.
Note: Ends of RODS shall be deburred Tolerance shall be as per IS:2102
(Detail as per GR, Unless UNTILL Specified)

Description
Protective HElx

Material
Aluminium Alloy 6061

Ref Spec

Qty

A.14

Armour Grip Suspension Set:

For Example
Dimensions:- Cable Size 14.4 MM DIA
Cable DIA

L1

L2

L3

L4

Colour Code

14.4

115

200

800

1400

Brown

DIA AGS
ROD
4.250.1

Note: Dimensions for different Cable Sizes to be decided after TEST Approval insert Dimensions in MM
Inner DIA
AT A- A - 22
AT B-B -22
Outer DIA
33
60

1
2
3
4
5
6
7
8
9

Description
Clamp
Inserts) Suspen Clipper
Strap
AGS Helix
Protective Helix
Rivet M16
Flat Washer
Split Pin
Twisted Eye

A.15

Material
Aluminium Alloy GDC
Polychloroprene Compounded
Aluminium Alloy
Aluminium Alloy6061
Aluminium Alloy6061
Mild Steel Galvanised
Mild Steel Galvanised
Stainless Steel
Mild Steel Galvanised

Ref Spec
IS:617
IS:617

IS:2062
IS:2016
IS:2549
IS:2062

Spiral Vibration Damper:

Dimensions in MM:
L1
1346

GL
446

DL
900

D1
121

Qty

Note: - Tolerance shall be as per IS:2102


(Detail as per GR, Unless UNTILL Specified)
Description
Material
1
Spiral Visration Damper
Polyvinyl Cokpounded

A.16

W1
50

W2
92

Note: - Tolerance shall be as per IS:2102


(Detail as per GR, Unless UNTILL Specified)
FEROUS PARTS ARE HOT DIP GAVANISED as per IS.2629
Description
Material
1
HOOK
Galvanised Steel
2
BODY
Galvanised Steel
3
SPOOL
Aluminium Coated Neoprene
DEMOUNTABLE PULLY
NOT TO SCALE

Qty

Demountable Pulley :

Dimensions in MM:
L1
280

A.17

Ref Spec

D
12

Ref Spec

Unit-MM

Supply of Joint Enclosure & Splicing

Features
Standard fiber count 24 to 48 F
Universal type i.e. suitable for all type of cable (ADSS OFC, Armoured
and metal free cable)
Provide scope for straight / branch joints
Resistant to chemicals and corrosive atmosphere.
Easy re-entry and closing with mechanical plastic clamp.
Shall be water and air proof.
Ribs on the body for extra strength
6 Cable entry port & 1 oval port
Suitable for cable size upto-30mm
Mounting Bracket for erecting on pole vertically straight.
Dome type
Dimensions
Length-395mm 5%

Qty

Outer diameter-273mm 5%

Annexure-III
Schedule-A
SL No.

Item Description

1.

Rate per kilometer for commissioning of last mile 4 core optical fibre
connectivity from the PoP room to the CPE point in the Government
office. The cost shall include the optical fibre and all the relevant
accessories/fittings/splicing/splitting etc. and installation of CPE at the
office and testing of the link from PoP to office.

2.

Rate per kilometer for commissioning of last mile 24 core optical fibre
connectivity from the PoP. The cost shall include the optical fibre and all
the relevant accessories/fittings/splicing/splitting etc.

Unit rate (in Rs.)

Вам также может понравиться