I.

ELECTRICAL:
A.

1.

2.

Lighting system:

The Lighting distribution and outlets will be as per Interior


Decorator.

YES

The lighting lamps will be of the enerrgy saving type.


YES

We have brass work and we may need special conventional lamps for
that.

Others:

3.
Shall there be indirect lights for all arreas catering false ceiling?
Per design

Others:

4.
Shall we use led lights for the projecct, or in specific areas?
Per design

Others:

5.

Shall there be lighting circuits fed fro


om UPS for each zone
inside the project premises?
We need a generator to run specific areas in case of emergency

The Lighting Control will be conventiional (Switches) or by push


buttons via latching relay
Dimmer switches

Others:

6.

YES

Others:

7.
Is EIB system required for the projecct? I yes, specify the areas.
Yes, in all

Main Salons
Receptions
Majlis
Dining Room
Patios
Corridors
Bedrooms
Girls Main Bedroom
oom
Marakech Patio
Family living room
Boys living area

CONSULT
Consultancy & Engineerin
ng Services
Beirut-Lebanon
Parents living area
ea
Master Bedroom
Gym
Outdoor lighting
Sports facilities
Guest Room
Library
Sataf Offices
Father Office
Meeting Room
European salons
Japanese Basin
8.

If EIB is required, for which systems?


?

We need BMS system, so yes.

Lighting
Rolling shutters
Power & mechaniccal
Others:

9.

10.

The Landscape and faade lighting will


w be general to ensure
Security lighting. BMS
The Landscape switching will be thro
ough conventional
LCPLighting Control Panel installed
d inside the guard room or
photocell.

Emergency Lighting will be through


h self- contained emergency
battery kit fixtures inside technical arreas.
We need a generator that will implement this.

YES

YES

11.

12.

Others

Fence lighting will be used on the pe


eriphery of the project
YES

13.

Pool lighting will be fed from


m external lighting panels.
YES

CONSULT
Consultancy & Engineering
g Services
Beirut-Lebanon

B.
1.

2.

Power System:

General purpose convenience wall mounted


m
outlets will be
allocated as per Interior Decorator inside
i
decorative areas.

Is it required to install electrically ope


perated curtains/rolling
shutters/blinds? If yes, please speciffy the switching procedure
whether it is conventional ort through
h EIB .If EIB please specify
in which areas? All

YES

YES

EIB System
Main Salons
Receptions
Majlis
Dining Room
Bedrooms
Girls Main Bedroom
oom
Marakech Patio
Family living room
Boys living area
Parents living area
ea
Master Bedroom
Staff Offices
Father Office
European salons
Japanese Basin

3.

4.

5.

The project will cater for a compact substation


s
located at
ground floor main electrical room.
.

All electrical distribution systems willl be centralized in a


dedicated room at lower ground floor
oor to limit maintenance
access to technical areas and not ins
nside the palace.
.

Panel boards will be of the American


an standards.
.

YES

YES

YES
NO
Others:

6.

Main distribution switchboards (MDB


Bs) will house moulded
case circuit breakers and the lighting
g distribution panels will

CONSULT
Consultancy & Engineerin
ng Services
Beirut-Lebanon

house miniature circuit breakers. The


he final branch panels will
be located within the electrical closet
ets. Sockets in wet areas
will cater for earth leakage inside the panel board
.
7.

8.

9.

YES

Final branch circuit wiring and small sub-feeders (less than 16


mm sq.) will be by means of single core
c
PVC insulated, copper
conductor, color coded drawn in PVC
C conduits.

YES

Voltage drop will be limited to 3% on feeders and sub-feeders


combined; branch circuits will be allo
owed a maximum of 2%
voltage drop

YES

The following loads are considered ccritical loads, thus will be


fed from UPS units.

100 % computer systems wiithin the project.

Surveillance and security syystems not equipped with


stand-by battery-set.

Fire alarm system

Communication systems

TV outlets

Miscellaneous sockets

No backup power supply generator w


will be installed within the
project since the main power supplyy from SEC is reliable
We need a generator

YES

10.

11.

12.

All electrically operated equipment req


equiring a fixed connection
or heavy electric power, will be supp
plied by means of a flexible
cord from a suitable isolating switch mounted on the wall
adjacent to the equipment.
Connection between main low voltag
age/ Low Current rooms to
electrical closets will be through ducct bank as per
recommended practices

Others

YES

YES

CONSULT
Consultancy & Engineering
g Services
Beirut-Lebanon
C.

1.

The TN-S system arrangement will be applicable;


ap
this means
that separate neutral and protective
e conductors throughout
the electrical distribution will be imp
plemented on the LV
distribution system and in full comp
pliance with the IEE
regulations

D.

1.

2.

3.

4.

5.

YES

Lightning System:

Is Lightning system required? yes


E.

1.

Earthing System:

Fradays Cage

Telephone System

Main telephone line will be terminated


nated to the villa premises to
an EPABX installed inside the teleccom cabinet.

YES

The telephone system in the villa willl be designed to enable


two-way internal communication with
hin the project and two-way
national/international external comm
munication.

YES

The telephone outlets will be installed


ed in all indoor occupied
areas, technical rooms, and thus pro
oviding complete internal
communication.

YES

Is it required to install telephone outtlets in the outdoor areas?


If yes, please specify in which areass? To fix which areas

The telephone system will be convent


ntional (CAT3 cables), or
CAT6 (termination via patch panel) ttaking into consideration
future IP telephony

YES

CAT3

CONSULT
Consultancy & Engineerin
ng Services
Beirut-Lebanon

6.

WIFI access points will be provided to ensure


en
internet
connection inside the project.

F.

YES

Telephone System (do you mean data system)

1.

1.

data points outlets RJ45


Is it required to ensure fixed d

YES

Shall we provide data points near each


ea television outlet for
future IP TV Wireless
NO

G.

TELEVISION SYSTEM

1.

What type of TV signal distribution iss required for the palace?


Multi-switch system
tem

H.
1.

FIRE ALARM SYSTEM


Fire detection system will cover the
he whole palace according to
NFPA72

2.

Interface between fire alarm system


tem and mechanical systems
to turn on/ of HVAC equipment in ccase of fire

I.

CCTV SYSTEM

1.

YES

Is it required to have a CCTV system


tem inside the project?

YES

YES

CONSULT
Consultancy & Engineerin
ng Services
Beirut-Lebanon

2.

What is the purpose of CCTV system


tem required?

Partial surveillance
e at the entrances

3.

Shall there be interface between the CCTV system and the


indoor TV system

YES

J.
1.

2.

K.

Video Interphone SYSTEM


Is it required to have a Video Interph
phone system inside the
project?

Shall there be interface between the video interphone / indoor


TV and CCTV system?

YES

Intrusion SYSTEM
1.

L.

YES

Is it required to have an Intrussion system inside the


project?

YES

Audio-Visual SYSTEM
1.
2.

Is it required to have anAudio


o visual system inside the
project?
If yes, please specify in which
h areas.

YES

CONSULT
Consultancy & Engineering
g Services
Beirut-Lebanon
II.

MECHANICAL:
A.

1.

Sanitary Soil and Waste Drai


ainage:

One pipe system. (Waste and drainage


age connected to one pipe)
YES

2.

3.

4.

Gravity system discharging at ground


und level to external sewer
network lead to municipality networkk.

YES

Drainage from Main Kitchen will be p


piped separately and lead
to grease interceptor pit prior discha
harging into sewage network.

YES

Drainage from basement shall be co


ollected by gravity to a
collection pit and then pumped to the
e external sewage network
by mean of submersible pumps.

B.
1.

YES

Rain Water Drainage:

Collecting rainwater from all roof areas


eas to leaders.
YES

2.

Leaders to freely discharge at grade


de level
YES

C.
1.

Domestic Cold Water Supplly:

Domestic water supply will be obtain


ned from external water
distribution network through the ava
ailable municipality
connections complete with water meter.
m

YES

CONSULT
Consultancy & Engineerin
ng Services
Beirut-Lebanon

2.

Water supply from municipality netwo


work will be stored in a
dedicated concrete water tank at a capacity
c
of 3-day supply.

Others:

7 days
3.

Water from municipality network to be stored in dedicated


untreated water tank

4.

YES

Water is filtered then stored in a trea


eated water tank.
YES

5.

Water is then pumped to all fixtures b


by means of central
booster pressurizing unit.
D.
1.

2.

1.

Domestic Hot Water Supply


y:

Domestic hot water will be supplied


ed to all toilets, and kitchen
sinks

Stand alone electrical water heater shall be provided above


false ceiling in each toilet or for a group
g
of adjacent toilets and
kitchen.

E.

YES

YES

YES

Fire Protection:

Portable dry chemical fire extinguishe


hers located throughout the
project as required by NFPA.

We have fire alarm system that is connected to the BMS, so FHCs are
enough but to be distributed wisely.

NO

CONSULT
Consultancy & Engineering
g Services
Beirut-Lebanon

2.

Fire hose cabinet / Rack to be added


d location to be as per
NFPA requirements

F.
1.

Landscape Irrigation System:


em:

Using the external cold water networrk as the source of


irrigation water. We need a well

2.

Irrigation capacity will be contained iin the untreated water tank

3.

Irrigation booster pumps will deliver water to the main


distribution irrigation network.

4.

Design of the irrigation network to be done by a specialist.

G.

Swimming Pools.

1.

YES

Heating for the swimming pool water will not be provided.

Others:

YES

YES

YES

Others:

Yes it should be provided

2.

3.

The swimming pool mechanical system


tem will pay attention to
water disinfection, filtration and circu
ulation.

YES

Indoor swimming pool area to be air conditioned


YES

CONSULT
Consultancy & Engineerin
ng Services
Beirut-Lebanon

H.

Heating Ventilation and Air Condittioning:

AHU + Chillers (humidity/perfect filtration/ionization)

1.

2.

Option One: The air condoning sysstem will be achieved by


direct expansion units of heat pum
mp type whether package
roof top units or DX splits.

Option Two: The air condoning system


tem will be achieved by
direct expansion units of heat pump VRV and DX splits.

YES
NO
Others:

YES
NO
Others:

3.

4.

5.

If Option One to follow: Roof top un


nits to be used in salons,
dinning, Gym, Reception, swimming
ng pool area, and bed rooms
and Split DX to be used in service, and guard rooms.

If Option Two to follow: VRV units to be used in salons,


dinning, Gym, Reception, swimming
ng pool area, and bed rooms
and Split DX to be used in service, and guard rooms.

All toilets will be mechanically ventilat


ated through exhaust fans.

YES
NO
Others:

YES
NO
Others:

YES
NO
Others:

6.

7.

Exhaust from kitchen will be mechan


hanically ventilated through
exhaust fans and will be discharged at roof level.

Main Mechanical Room and Electriccal Rooms: Mechanical


ventilation system will be provided for
or main mechanical room
at basement level by means of fresh
h air supply and exhaust
fans.

YES

YES

CONSULT
Consultancy & Engineerin
ng Services
Beirut-Lebanon

I.
1.

Building Management System:

Building management system to devvelop, store, access the


system operation

YES

Project Manager:
Manager:
Name:
Activity:

Checked
Approved
Rejected