Problem Statement:

PLAN OF THE BUILDING:


4m
4m

3m

4m

X-axis

4m

C2

C1

C1

C1

C1

C2

C1

C3

C3

C3

C3

C1

C2

C1

C1

C1

C1

C2

5m

5m

Z-axis
ELEVATION OF THE BUILDING:
6. 5th.Floor/ Terace

3m
3m
3m
3m
3m

5. 4th. Floor
4. 3rd. Floor

3. 2nd. Floor

2. 1st. Floor

1. G.F

1.5 m base Level

4th. Storey
3rd. Storey
2nd Storey
1st. Storey
Ground
Storey

300 x 600

300 x 600

300 x 500

300 x 500

300 x 500

300 x 500

300 x 500

300 x 600

300 x 600

300 x 500

300 x 500

300 x 500

300 x 500

300 x 500

300 x 600

300 x 600

300 x 500

300 x 500

300 x 500

300 x 500

300 x 500

300 x 600

300 x 600

300 x 500

300 x 500

300 x 500

300 x 500

300 x 500

300 x 600

300 x 600

300 x 500

300 x 500

300 x 500

300 x 500

300 x 500

300 x 400

300 x 400

300 x350

300 x350

300 x350

300 x350

300 x350

1. Building Type
: G+4 Storey RC Office Building
2. Dimension ( L x B ) : 19 m x 10 m
3. Building Heght (h) : 15m

7. Grade of Concrete
8. Grade of Steel
9. Live Load on roof

: M25
: Fe 415
: 1.5 Kn/mm2

4. Floor Heght (h)

: 3m

10. Live load on floor

: 3 Kn/m2

5. Sismic Zone (h)

:V

11. Roof finsih

: 1 Kn/m2

6. Soil Type

: Medium

12. floor finish


13. Brick Wall (Ext.)

: 1 Kn/m2
: 230 mm

Sizes of Beam:
Floor Level
Terrace
4th.
3rd.
2nd
1st
G.F

X-axis
YD
300
300
300
300
300
300

Sizes of Column:
C1
300 x 500
C2
400 x 400
C3
400 x 500

Z-axis
ZD
500
500
500
500
500
350

YD
300
300
300
300
300
300

ZD
600
600
600
600
600
400

Slab Thickness: 125 mm


Note: Column sizes uniform through out

14. Brick Wall (Int.)


:150 mm
15. Density Conc.
: 25 Kn/mm2
16. Density brick + Plast : 20 Kn/mm2

5 Kn/mm2

0 Kn/mm2

1. Fundamental Natural Period Ta in Seconds


a) Moment resisting frame building without brick infill panel
Ta (sec)
h (m)
h0.75
STAAD
16.5
8.1868
0.61401
Px and Pz
b) Moment resisting frame building with brick infill panel
STADD
dx or dz (m)
Ta (sec)
h (m)
parameter
19
16.5
0.34068
Px
10
16.5
0.46960
Pz

2. Spectral Accelaration Coefficient (Sa/g)


For rocy or Hard Soil
Range of T
0.00 T 0.10
0.10 T 0.40
0.40 T 4.00
For Medium Soil Site
Range of T
0.00 T 0.10
0.10 T 0.55
0.55 T 4.00
For soft Soil Site
Range of T
0.00 T 0.10
0.10 T 0.67
0.67 T 4.00

T
0
0
0

Sa/g
1.00
2.50
#DIV/0!

T
0
0
0

Sa/g
1.00
2.50
#DIV/0!

T
0
0
0

Sa/g
1.00
2.50
#DIV/0!

3. Design Base Shear (Vb)


Zone
Zone factor
Importance factor
Resp.reduc. factor

Spectral Acc. Coeff.

V
0.36
1
5

Z
I
R
Sax/g
Saz/g

2.50
2.50

Ahx
Design hor. seismic.
Ahz
Coeff.
Seismic Weight of the Building
W
VBx
Design Base Shear

0.0900
0.0900
13924 kN
1253 kN

VBz

1253 kN

3. Lateral Load distribution

Storey Level

6
5
4
3
2
1

Wi (kN)
2154.000
2677.000
2677.000
2677.000
2677.000
1062.000
13924

hi (m)
16.50
13.50
10.50
7.50
4.50
1.50

Wihi2
586426.5
487883.25
295139.25
150581.25
54209.25
2389.5
1576629

Wihi2 / Lateral force at ith. Level


Wihi2 for EL in direction (kN)
0.37195
0.30945
0.18720
0.09551
0.03438
0.00152
1.00000

X
466.05
387.74
234.56
119.67
43.08
1.90
1253.00

Z
466.05
387.74
234.56
119.67
43.08
1.90
1253.00

STOREY HEIGHT
'h'

STOREY NO.

FLOOR
1

TOTAL
SLAB
AREA
'A'

Slab
thick.
't'

'm'

m2

kN/m2

kN/m2

kN/m2

kN/m2

kN/m2

kN

10

11

190.00
190.00
190.00
190.00
190.00
0.00

0.125
0.125
0.125
0.125
0.125
0.00

3.125
3.125
3.125
3.125
3.125
0.000

0.000
0.000
0.000
0.000
0.000
0.000

1.000
1.000
1.000
1.000
1.000
0.000

1.500
3.000
3.000
3.000
3.000
0.000

0.00
0.75
0.75
0.75
0.75
0.00

783.750
926.250
926.250
926.250
926.250
0.000
4488.750

Roof
4th.
3rd.
2nd.
1st.
G.F.

LOAD 1: MASSOF FLOOR SLABS


DL intensity
Self wt. water
Roof
25t proofing finish
load
load etc.

LL Fraction SEISMIC
intensity *LL
LOAD
(0.00L/
Ax
0.25LL/
(DL
0.50LL) +*LL)

LOAD 2: MASS OF FLOOR BEAMS


STOREY
HEIGHT
'h'

STOREY NO

FLOOR

G.Total - 1

'm'
Roof
4th.
3rd.
2nd.
1st.
G.F.
Sub-Total A

BEAM TYPE-I
Cros-section

BEAM TYPE-II

Total L

Self
Weight

Cros-section

BEAM TYPE-III

Total L

Self
Weight

Cros-section

BEAM TYPE-IV

Total L

Self
Weight

Cros-section

Total L

Self
Weight

BDL

25BDL

25BDL

25BDL

kN

kN

kN

kN

0.300
0.300
0.300
0.300
0.300
0.300

0.500
0.500
0.500
0.500
0.500
0.350

57.00
57.00
57.00
57.00
57.00
57.00

201.452
201.452
201.452
201.452
201.452
141.016
1148.275

0.300
0.300
0.300
0.300
0.300
0.300

0.600
0.600
0.600
0.600
0.600
0.400

60.00
60.00
60.00
60.00
60.00
60.00

254.465
254.465
254.465
254.465
254.465
169.644
1441.970

2590.24

STOREY HEIGHT
'h'

FLOOR

STOREY NO

G.Total - 2

LOAD 3: MASS OF COLUMNS (SELF WT.)


COLUMN GROUP C1

COLUMN GROUP C2

nos*h

Self
Weight
BDL

0.300
0.300
0.300
0.300
0.300
0.300

0.500
0.500
0.500
0.500
0.500
0.500

30.000
30.000
30.000
30.000
30.000
15.000

Cros-section

Total L

COLUMN GROUP C3

nos*h

Self
Weight
BDL

kN

106.027
106.027
106.027
106.027
106.027
53.014
583.150

0.400
0.400
0.400
0.400
0.400
0.400

0.400
0.400
0.400
0.400
0.400
0.400

12.000
12.000
12.000
12.000
12.000
6.000

Cros-section

Total L

COLUMN GROUP C4

nos*h

Self
Weight
BDL

kN

kN

45.238
45.238
45.238
45.238
45.238
22.619
248.810

0.400
0.400
0.400
0.400
0.400
0.400

0.500
0.500
0.500
0.500
0.500
0.500

12.000
12.000
12.000
12.000
12.000
6.000

56.548
56.548
56.548
56.548
56.548
28.274
311.013

Cros-section

Total L

nos*h

Self
Weight
BDL

kN

Cros-section

Total L

'm'
6
3.00
5
3.00
4
3.00
3
3.00
2
3.00
1
1.50
Sub-Total A
G.Total - 3

1142.97

LOAD Intensity of BRICK WALL & PLASTER


Brick
Wall

Plaster
thick
Density
thick.
(both
Brick
side)

STOREY HEIGHT
'h'

Wall Location

m
Ext. Wall 0.230
Int. Wall 0.150

kN/m3
20.00
20.00

Density Load
Plaster intensity
kN/m3

kN/m2
4.60
3.00

LOAD 4: MASS OF BRICK WALL + PLASTER


Along X-axis
External Wall
wall
Total
Average
height length
Beam D
h'= h-D
L

Internal Wall
Load
wall
Total
Average
imposed
height length
Beam D
L*h'*i
h'= h-D
L

Along Z-axis
External Wall
Load
wall
Total
Average
imposed
height length
Beam D
L*h'*i
h'= h-D
L

Internal Wall
Load
wall
Total
Average
imposed
height length
Beam D
L*h'*i
h'= h-D
L

Load
imposed
L*h'*i

'm'
Terrace
1.00
Storey-6
3.00
Storey-5
3.00
Storey-4
3.00
Storey-3
3.00
Storey-2
3.00
Storey-1
1.50
Sub-Total A

m
0.000
0.500
0.500
0.500
0.500
0.350
0.000

m
1.00
2.50
2.50
2.50
2.50
2.65
1.50

m
38.00
38.00
38.00
38.00
38.00
38.00
0.00

kN
174.80
437.00
437.00
437.00
437.00
463.22
0.00
2386.02

m
0.000
0.500
0.500
0.500
0.500
0.350
0.000

m
0.00
2.50
2.50
2.50
2.50
2.65
1.50

m
19.00
19.00
19.00
19.00
19.00
19.00
0.00

G.Total - 4

Total Seismic Mass W= Load 1 + Load 2 + Load 3 + Load 4=

kN
0.00
142.50
142.50
142.50
142.50
151.05
0.00
721.05

m
0.000
0.600
0.600
0.600
0.600
0.400
0.000

m
1.00
2.40
2.40
2.40
2.40
2.60
1.50

5785.47

14007.438

kN

m
20.00
20.00
20.00
20.00
20.00
20.00
0.00

kN
92.00
220.80
220.80
220.80
220.80
239.20
0.00
1214.40

m
0.000
0.600
0.600
0.600
0.600
0.400
0.000

m
1.00
2.40
2.40
2.40
2.40
2.60
1.50

m
0.00
40.00
40.00
40.00
40.00
40.00
0.00

kN
0.00
288.00
288.00
288.00
288.00
312.00
0.00
1464.00