Вы находитесь на странице: 1из 23

ENGINUITY SERVICE PACK README

EMC VMAX and VMAXe Series


Enginuity Operating Environment
ReadMe for Enginuity Service Packs
Release Level 5876.286.194
REV 08
April 29th, 2016

This Enginuity Service Pack ReadMe contains specific information for Enginuity Pack
registered build 5876_286/0115 and SymmWin registered build 5876_194/5012. Topics
include:

ReadMe revision history ............................................................................................ 2


Audience .................................................................................................................. 2
Installation ............................................................................................................... 2
Service Pack release history ...................................................................................... 3
Service Pack overview ............................................................................................... 5
Fixed problems ......................................................................................................... 6
Firmware Pack release history ................................................................................. 15
Troubleshooting and getting help............................................................................ 22

ReadMe revision history

ReadMe revision history


Table 1 presents the revision history of this document.
Table 1

ReadMe revision history


Revision

Date

Description

01

August 3, 2015 First release of EMC Proactive Enginuity Pack ReadMe containing
specific information for Enginuity Pack registered build
5876_286/0008 and SymmWin registered build 5876_194/5003.

02

October 16,
2015

Second release of EMC Proactive Enginuity Pack ReadMe containing


specific information for Enginuity Pack registered build 5876_286/0033
and SymmWin registered build 5876_194/5006 to include fixes
20014759, 20016989, 80989, 82682, 83200, 83527, 84462.

03

December 10,
2015

Third release of EMC Proactive Enginuity Pack ReadMe containing


specific information for Enginuity Pack registered build 5876_286/0054
and SymmWin registered build 5876_194/5008 to include fixes
20017540, 20017541, 485454, 80152, 81030, 81114, 81558, 81589,
81679, 82683, 82877, 83023, 83111, 83178, 83546, 83722, 85781.

04

February 5,
2016

Update to Firmware Pack release history to include February 5th, 2016


5876 firmware pack release.

05

February 15,
2016

Fourth release of EMC Proactive Enginuity Pack ReadMe containing


specific information for Enginuity Pack registered build 5876_286/0092
and SymmWin registered build 5876_194/5012 to include fixes 86837,
20017910, 86382, 85042, 85029.

06

March 18,
2016

Update to Firmware Pack release history to include March 18th, 2016


5876 firmware pack release.

07

April 1, 2016

Fifth release of EMC Proactive Enginuity Pack ReadMe containing specific


information for Enginuity Pack registered build 5876_286/0115 and
SymmWin registered build 5876_194/5012 to include fixes 87809,
87142, and to remove fix 81030.

08

April 29, 2016

Update to Firmware Pack release history to include April 26th, 2016


5876 firmware pack release.

Audience
This document is primarily intended for EMC customers but it can also be used by EMC
Customer Service personnel.
Note: The Enginuity Service Pack ReadMe document contains technical information that
requires the reader to have some primary knowledge of EMC hardware and software
products.

Installation
Enginuity release level 5876.286.194 is available for download from
https://support.EMC.com. Please note that the installation procedure can only be
performed by your local EMC representative.

Enginuity Release Level 5876.286.194 Enginuity Service Pack ReadMe

Service Pack release history

Service Pack release history


Table 2 presents the revision history of the Enginuity Service Packs for release level
5876.286.194.
Note: The last Enginuity Service Pack listed in Table 2 is the most current pack for release
level 5876.286.194. This pack should be treated as a superset of all previously released
packs; that is, it contains all previously released fixes plus any new or modified fixes. New
fixes or OPTs in the Fix numbers/OPT numbers column are highlighted in bold.
Table 2

Enginuity Service Pack revision history

Released

Enginuity level

Enginuity reg.
build

SymmWin reg.
build

Fix numbers/OPT
numbers

Engineering Full Firmware Pack


ID
file

08/3/15

5876.286.194

5876_286/0008

5876_194/5003

77863*, 79739,
20017047, 81666,
81117

5303

fw_pack_full_150
603_162642.exe

10/16/15

5876.286.194

5876_286/0033

5876_194/5006

77863*, 79739,
20017047, 81666,
81117, 84462,
83527, 83200,
82682, 20016989,
80989, 20014759

5393

fw_pack_full_150
929_121255.exe

12/10/15

5876.286.194

5876_286/0054

5876_194/5008

79739, 20017047,
81666, 81117,
84462, 83527,
83200, 82682,
20016989, 80989,
20014759,
20017540,
20017541, 485454,
80152, 81030,
81114, 81558,
81589, 81679,
82683, 82877,
83023, 83111,
83178, 83546,
83722, 85781

5480

fw_pack_full_151
130_192500.exe
released on
12/10/15
fw_pack_full_160
122_114424.exe
released on
02/05/2016

Enginuity Release Level 5876.286.194 Enginuity Service Pack ReadMe

Service Pack release history

Table 2

Enginuity Service Pack revision history (continued)

Released

Enginuity level

Enginuity reg.
build

SymmWin reg.
build

Fix numbers/OPT
numbers

Engineering Full Firmware Pack


ID
file

02/15/16

5876.286.194

5876_286/0092

5876_194/5012

79739, 20017047,
81666, 81117,
84462, 83527,
83200, 82682,
20016989, 80989,
20014759,
20017540,
20017541, 485454,
80152, 81030,
81114, 81558,
81589, 81679,
82683, 82877,
83023, 83111,
83178, 83546,
83722, 85781
86837, 20017910,
86382, 85042,
85029.

5572

79739, 20017047,
81666, 81117,
84462, 83527,
83200, 82682,
20016989, 80989,
20014759,
20017540,
20017541, 485454,
80152, 81030,
81114, 81558,
81589, 81679,
82683, 82877,
83023, 83111,
83178, 83546,
83722, 85781,
86837, 20017910,
86382, 85042,
85029, 87809,
87142

5658

04/01/16

5876.286.194

5876_286/0115

5876_194/5012

*.This fix was replaced by fix 85781 in Service Pack ID# 5480.
.This fix was removed in Service Pack ID# 5658.

Enginuity Release Level 5876.286.194 Enginuity Service Pack ReadMe

fw_pack_full_160
122_114424.exe
released on
02/05/16
fw_pack_full_160
309_151553.exe
released on
03/18/16

fw_pack_full_160
309_151553.exe
released on
04/01/16
fw_pack_full_160
419_102029.exe
released on
04/26/16

Service Pack overview

Service Pack overview


EMC is dedicated to providing a solid support strategy for its customers by ensuring they
have the most up-to-date fixes and enhancements. Enginuity Service Packs are a key part
of this strategy as they provide important supplementary information for each Service
Release.
Each Enginuity Service Pack also contains the latest Firmware Pack. The Firmware Pack
ReadMe can be downloaded from: https://support.EMC.com. For the release history of the
Firmware Packs, see Table 8 on page 9.
Two Enginuity Service Packs are released per code family: one at the target level and one
at the latest code level, with each pack consisting of a set of highly recommended fixes.
The following information should be noted for each Enginuity Service Pack:

A new Enginuity Service Pack should be treated as a superset of all previously


released packs for that code family; that is, a new pack will contain all previously
released fixes plus any new or modified fixes.

If a fix is removed between Enginuity Service Packs, information will be included on


the fix that has been removed.

If a fix is updated between Enginuity Service Packs, information will be included on


the revision number of the fix.

All fixes released in an Enginuity Service Pack will be integrated into the next Service
Release of the code family.

Enginuity Release Level 5876.286.194 Enginuity Service Pack ReadMe

Fixed problems

Fixed problems
This section highlights product issues that are fixed in this Enginuity Service Pack. Product
issues are listed alphabetically by product feature and by service request number within
each product feature. The following details are available for each product issue:

Service request numberUnique case number assigned to track the problem. If the
problem was found during product testing by EMC, the case number contains the
abbreviated product name.

Fix numberNumber of the patch or fix for the problem.

Problem summaryHigh-level summary of the problem being reported.

ImpactPotential impact of the issue.

Knowledgebase article (optional)Number of a relevant EMC Knowledgebase


solution.

Additional information (optional)Any additional information about the fix, for


example, if the fix is new, modified, or removed.

Enginuity Release Level 5876.286.194 Enginuity Service Pack ReadMe

Fixed problems

Base Functionality

Service request
number
75917586,
75561742

Table 3

Base Functionality

Fix number

Problem summary

Impact

86382

If during a director full initialization


process the directors encounter 80EF.0C
PCIE non-fatal errors, the fabric path
associated to one System Interface Board
(SIB) may be disabled (80DD.00 error)
during the process without notifying the
other directors.
This inconsistency view of SIB path
availability between directors will trigger a
data unavailability event.

Knowledgebase
article

Additional
information

Potential Data
unavailability

211944

Fix added on
February 15, 2016

Potential Data
Unavailability

N/A

N/A

Potential Data
Unavailability

200387

N/A

Potential Data
Loss/Data
Unavailability

206885

Fix added on
October 16, 2015

Potential Data
Loss/Data
Unavailability

204002

Fix added on
October 16, 2015

Errors: 80EF.0C, 80DD.00


Special conditions: Exposure is in VMAX
40K environments.
67982458,
71172720

81117

When a host accesses a track that is held


in cache but the cache holder is "free", the
Fiber Channel Director repeatedly issues
error 8610.02. This continues until the
host operation times out, generating error
xx3C.
Errors: 8610.02, xx3C.

72096506,
66452372,
69932410,
69925882,
70121510,
70889538,
70251386,
70385632,
72568664

79739

73831038,
72828274

84462

XX1F or F11F errors on Fibre Channel


directors may cause the directors to free
slot locks (2812 errors), resulting in xx2C
errors with Sector Signature mismatch.
Errors: XX1F, F11F, 2812, xx2C.

Windows Offloaded Data Transfer (ODX)


commands may trigger common lock
contention that is causing the Enginuity
emulation to become unresponsive or
drop not operational.
Exposure: 5876.286.194 (with fix 77179)

71840404

83200

When using cache partitioning, the write


pending counter might report a negative
count. A task to recover the counter runs
on multiple directors in parallel and might
lead to one or more directors becoming
unavailable.
Errors: D80B.7C, EB63.51, 6510.01

Enginuity Release Level 5876.286.194 Enginuity Service Pack ReadMe

Fixed problems

Table 3

Base Functionality

Service request
number

Fix number

Problem summary

Impact

68444966

80989

A cluster could lose its reservation on a


disk that was unmapped from the original
FA directors using SymmWin or a SYMSLI
command (such as symmaccess -sid
xxx view delete -unmap). In turn,
this caused the cluster to failover.

488482SYM

85781

This fix corrects an error in the handling of


Deferred Table Rebuild (DTR) on Not Ready
devices and replaces fix 77863.

Knowledgebase
article

Additional
information

Potential Data
Loss/Data
Unavailability

197551

Fix added on
October 16, 2015

Potential Data
Unavailability

N/A

Added on 10
December, 2015.

Errors: A410, C010.


Special conditions: At least one member
not ready in the RAID group with DTR set.
73450686,
74238012,
73605370,
74764268

83023

The Disk Adapter (DA) scheduler task


contains a setting that defines the amount
of CPU capacity for the task (usually,
25%). This setting can get incorrectly set,
restricting the DA task to 1% of the CPU. In
turn, this drastically increases the time for
SRDF operations such as failover, R2
Refresh, Merge, Establish, and thin pool
movement to complete.

Potential Data
Loss/Data
Unavailability

174781

Added on 10
December, 2015.

78095032

87809

The Enginuity emulation keeps logging


BADD.D1 errors over and over on the same
drive calling for the drive. The error keeps
logging even after the drive has been
replaced.
The problem was introduced by fix 86837
that leave internal DA BMSI variables
uninitialized.

Potential
Maintenance
Issue

479667

Added on 1 April,
2016.

Potential Data
Unavailability

462921

Added on 1 April,
2016.

Errors: BADD.D1
76751000,
77639774,
77384290,
76494808,
77008140

87142

Fix 81030 may trigger a Data


Unavailability event (xx3C) when software
applications (such as Clone activate, SRDF
split, or ORS activate) that are using
Consistency Groups (Enginuity
Consistency Assist (ECA) windows) are
aborted and they leave the ECA bit set on
the devices.
Errors: xx3C

Enginuity Release Level 5876.286.194 Enginuity Service Pack ReadMe

Fixed problems

Enhancements
Table 4

Enhancements

Fix number

Problem summary

Impact

76517586,
76904212,
76904240,
77112034,
76985142

86837

Enhancement for Hitachi Viper-C failure


detection.
This fix monitors internal disk logs to
detect early failures, posts a BADD.xx
error, and invokes the Data Migration
Service (DMS) operation via the SymmWin
AutoPSE_Disk script.

72881416,
73934134

83527

72881416,
74008454

20016989

Service request
number

Knowledgebase
article

Additional
information

Potential Data
unavailability

212142

Fix added on
February 15, 2016

This enhancement adds support for


storing Deferred Disk Service (DDS)
threshold values in the static
configuration file (impl.bin).
Fix 83527 requires fixes 20014759, and
20016989 to deliver a full DDS solution.

No impact

N/A

Fix added on
October 16, 2015

Enhancement of the DDS.


Previously, Enginuity sent a Dial Home
message following a disk failure if one
further failure would compromise the
configured RAID protection. Now, the
system can be configured to send a
message before that limit is reached. This
allows servicing to occur before a situation
becomes critical.

No impact

N/A

Fix added on
October 16, 2015

No impact

N/A

Fix added on
October 16, 2015

No Impact

176765

Added on 10
December, 2015.

Fixes required: 83527, 20014759,


20016989
72881416

20014759

Enhancement of the DDS.


SymmWin now sends a dial home
message whenever the Deferred Service
Enabled field on the SITEINFO tab is
changed from ENABLED to DISABLED.
Fixes required: 83527, 20014759,
20016989.

69757686,
71538468,
71188460,
73348418,
74500364

80152

In a VMware environment, this


enhancement reduces posting of the error
code 4622 to one instance per device on a
Fibre Channel director, per hour. The error
is posted in response to the unsupported
SCSI 0x46 (GET CONFIGURATION)
command. Multiple 4622 errors can lead
to error 04E1.0D (new PC error indicating
error buffer has been filled) and dial
homes.
Errors: 4622, 04E1.0D

Enginuity Release Level 5876.286.194 Enginuity Service Pack ReadMe

Fixed problems

Fibre Channel
Table 5

Fibre Channel

Service request
number

Fix number

Problem summary

Impact

469464SYM

81114

This fix adds SRDF support between


Enginuity 5876.286.194 and HYPERMAX
OS 5977.
Zero data detection between Enginuity
5876 and HYPERMAX OS 5977 arrays
might fail for compressed IO and as a
result, Thin devices might not get
unallocated.

Potential Data
Unavailability

Table 6

Mainframe

Service request
number

Fix number

Problem summary

Impact

69154554

81666

Mainframe GDDR Autoswap may fail,


resulting in Mainframe requiring Initial
Program Load (IPL). This occurs because
the FICON directors see a device as being
in a Not Ready state even if the Mainframe
Enabler software has set the device to
ready.

Potential Data
Unavailability

Knowledgebase
article

Additional
information

N/A

Added on 10
December, 2015.

Knowledgebase
article

Additional
information

199400

N/A

Mainframe

Errors: D233, EA33.23, E733.23.

Open Systems

Service request
number
72382266,
72462394,
73812340,
74170818,
74767798,
75073768,
74895954

Table 7

Open Systems

Fix number

Problem summary

Impact

Knowledgebase
article

Additional
information

83722

The symaccess validate command


may fail due to a mistaken belief that a
storage group in the masking database is
missing.

No Impact

204653

Added on 10
December, 2015.

Errors: 04DA.0C.
Special conditions: If there are many
non-contiguous storage group entries (due
to deletion), it is possible for some entries
to not show up in the second payload of
the read syscall because of mishandling of
the offset into the database.

10

Enginuity Release Level 5876.286.194 Enginuity Service Pack ReadMe

Fixed problems

Optimizer
Table 8

Optimizer

Service request
number

Fix number

Problem summary

Impact

74170446

485454

The Optimizer Server Manager might fail to


automatically restart the Optimizer VP
Server because the server might get stuck
in the Stopping state. This renders the
server unavailable, but VMAX arrays might
fail to call home when this occurs.

Potential Data
Unavailability

Knowledgebase
article

Additional
information

208123

Added on 10
December, 2015.

Enginuity Release Level 5876.286.194 Enginuity Service Pack ReadMe

11

Fixed problems

SRDF Family
Table 9

SRDF Family

Service request
number

Fix number

Problem summary

Impact

72005378

85029

In an SRDF environment, a host-driven


SRDF Syscall combined with a multi-path
gatekeeper configuration may trigger
2A2C, DEDA errors.
The errors are triggered when a Write
Pending (WP) cache slot is overwritten by
data from a host-driven SRDF syscall.

Knowledgebase
article

Additional
information

Potential Data
unavailability

208237

Fix added on
February 15, 2016

Potential Data
unavailability

207358

Fix added on
February 15, 2016

Errors: 2A2C, DEDA


72339328

85042

In an SRDF environment, when FAST


moves a track that is marked as Never
Written By Host (NWBH) and is Write
Pending (WP) to the SRDF mirror, Enginuity
will lose the SRDF WP indication resulting
in inconsistency between the SRDF R1 and
R2 device.
Errors: 5FCA, EC85.

71306844

82682

In an SRDF environment, throughput may


be impacted when a R1 FBA metadevice
(with greater than 4 members) on a VMAX
system running Enginuity 5876 is
connected to a R2 on a VMAX3 system
running HYPERMAX OS 5977. Exposed
environment: A VMAX system with striped
meta volumes running Enginuity 5876
connected to a VMAX3 system running
HYPERMAX OS 5977.

Potential
Performance
Issue

202707

Fix added on
October 16, 2015

477025SYM

83111

This fix adds SRDF support between


Enginuity 5876.286.194 and HYPERMAX
OS 5977.691.684.
The internal inlines command failover
-establish may fail when the R1 device
of an SRDF configuration is on a VMAX3
5977 array and the R2 device is on a VMAX
5876 array, the following error message is
received: "The operation is not allowed
because the R2 device is larger than the
R1 device".

Potential Data
Unavailability

N/A

Added on 10
December, 2015.

479606SYM

83546

When the Dynamic SRDF group request


removes support for a director/port
supported on the SRDF group for the local
VMAX system, the remote VMAX system
successfully updates the SRDF group
information, but does not remove from
service the links to the no longer
supported director/port.

No Impact

N/A

Added on 10
December, 2015.

Errors: 272F.

12

Enginuity Release Level 5876.286.194 Enginuity Service Pack ReadMe

Fixed problems

Table 9

SRDF Family

Service request
number

Fix number

Problem summary

Impact

476678SYM

82683

This fix adds SRDF support between


Enginuity 5876.286.194 and HYPERMAX
OS 5977.691.684.
Removing a port from the GigE group
topology may fail if the VMAX3 anchor
director was not the first GigE director
supporting the group.

475987SYM

82877

69832612,
73811662,
73828688

81679

Knowledgebase
article

Additional
information

Potential Data
Unavailability

N/A

Added on 10
December, 2015.

This enhancement provides SRDF


Active/Active support between Enginuity
5876.286.194 and HYPERMAX OS
5977.691.684.
The enhancement allows you to use both
sites as the source device (R1) and write to
both sites simultaneously.

No Impact

N/A

Added on 10
December, 2015.

When merging SRDF pairs between a


VMAX array and a VMAX3 array during a
device migration, the CLI command may
fail with the error "The Inline command
timed out".

Potential Data
Unavailability

199589

Added on 10
December, 2015.

Potential Data
Unavailability

N/A

Added on 10
December, 2015.

No Impact

N/A

Added on 10
December, 2015.

Exposed environment: Any SRDF CLI


command involving device pair table
merge (FDD).
Errors: EC86.04, A818.00.
472039SYM

81589

This fix adds SRDF support between


Enginuity 5876.286.194 and HYPERMAX
OS 5977.691.684.
SRDF links from a VMAX array to a VMAX3
array could bounce (FE3F error) when the
VMAX array writes on the special cylinder
(CE Cyl) which does not exist on the
VMAX3 system. The response to the write
is treated as an error by the Common
Driver Interface (CDI) which returns a
no_data_error.
Errors: 0xE (IOBS_NO_DATA_PHASE_ERR),
FE3F.

471912SYM

83178

This fix improves the maintainability of


SRDF between Enginuity 5876.286.194
and HYPERMAX OS 5977 by enhancing the
inline commands A7,META and
A7,MMAP.
Exposed environment: This enhancement
is primarily relevant for displaying
information about Fixed Block Architecture
(FBA) meta devices.

Enginuity Release Level 5876.286.194 Enginuity Service Pack ReadMe

13

Fixed problems

Table 9

SRDF Family

Service request
number

Fix number

Problem summary

Impact

471030SYM

81558

This fix adds SRDF support between


Enginuity 5876.286.194 and HYPERMAX
OS 5977.691.684.
This fix is needed to support remote
syscalls with RDF between 5876.286.194
(and above) and Indus 5977.691.684.

Potential
Performance
Issue

Table 10

SymmWin

Service request
number

Fix number

Problem summary

Impact

491884SYM

20017910

This fix updates the SymmWin Main


FlexFilter to revision 7621.0
The main change on this revision is linked
to fix 86837 to invoke SymmWin
AutoPSE_Disk on a BADD.xx error for
Hitachi Viper-C drives.

72046632,
71799612,
71700700

20017047

The fix adds a protection to the SymmWin


Online Code upgrade script to prevent the
user from accidentally removing the
Mainframe zBoost or Mainframe
Performance Accelerator (MPA) features.

Knowledgebase
article

Additional
information

N/A

Added on 10
December, 2015.

Knowledgebase
article

Additional
information

Potential Data
unavailability

212142

Fix added on
February 15, 2016

Potential Data
Unavailability

189941

N/A

SymmWin

Exposed environment: Arrays running the


MPA or zBoost features.
485199SYM

20017541

The fix incorporates the script


action_00CA.smp to reduce 00CA calls
home.

No Impact

184932

Added on 10
December, 2015.

485198SYM

20017540

The fix incorporates the script


action_CACA76.smp to reduce CACA calls
homes.

No Impact

91668

Added on 10
December, 2015.

14

Enginuity Release Level 5876.286.194 Enginuity Service Pack ReadMe

Firmware Pack release history

Firmware Pack release history


Each Enginuity Service Pack also contains the latest Firmware Pack. The complete ReadMe
document for Firmware Packs Release Level 5876 is available on
https://support.EMC.com. The release history of the Firmware Packs for the 5876 code
family along with the released fw_pack_full.exe files is shown in Table 11.
Note: The OPT numbers column provides the Service Release OPT number (SR OPT) for the
Firmware Packs. Only EMC personnel have access to the OPT system. Please contact your
local EMC representative for details.
Table 11
Release
date

Firmware packs release history


OPT
numbers

Full firmware pack file Firmware update file(s)

Description

26 April,
2016

fw_pack_full_160419 fw_160418_172254_A3HE030_AL1
_102029.exe
3SXB3.zip
fw_160418_172318_A3HE045_AL1
3SXB4.zip
fw_160418_172320_A3HE060_AL1
3SXB6.zip
fw_160418_172323_AKH7200_HUS
72602CLAR2000.zip
fw_160418_172333_AKH7400_HUS
72604CLAR4000.zip
fw_160418_172336_CFHF030_HUC
15603.zip
fw_160418_172345_CFHF045_HUC
15604.zip
fw_160418_172347_CFHF060_HUC
15606.zip

Added firmware 5507 for Toshiba


AL13SX drives.
Added firmware 350E for Hitachi King
Cobra-F drives.
Added initial 2503 firmware for HGST
Aries-K Plus drives.

498808

18 March,
2016

fw_pack_full_160309 fw_160211_115412_MGH7100_ST1
_151553.exe
000NXCLAR1000.zip
fw_160211_115518_MGH7200_ST2
000NXCLAR2000.zip
fw_160211_115539_MGH7300_ST3
000NXCLAR3000.zip
fw_160211_122349_MGH7400_ST4
000NXCLAR4000.zip
fw_160204_173900_AVH7100_STA
VSND2CLAR1000.zip
fw_160308_043136.zip

Added firmware 1002 for Seagate


Avenger drives.
Updated DriveDB to revision 4424 to
support Seagate SAS 2.5" 7.2K RPM
1TB Avenger drives.
Updated firmware to 710F for Seagate
Megalodon drives.

495494,
494420,
494243

5 February,
2016

fw_pack_full_160122 fw_151211_144817.zip
_114424.exe
fw_160119_205750_TBHA030_STT
BSND4.zip
fw_160119_205813_TBHA060_STT
BSND2.zip
fw_160119_205816_TBHA090_STT
BSND3.zip
fw_160119_205819_TBHA120_STT
BSND1CLAR1200.zip
fw_151016_164047_YJHE014_ST91
4685.zip
fw_151016_164156_YJHE030_ST93
0065.zip

Updated DriveDB revision to 4410 to


support Seagate Thunderbolt 300GB,
600GB, 900GB, 1200GB (Native SAS),
and for HGST Aries-K Plus (520n) SAS
3.5" 7.2K rpm 2/4TB drives.
Updated firmware to TS14 for Seagate
Thunderbolt 10K drives.
Updated firmware to 2516 for Seagate
YellowJacket drives.

488993,
490511,
486821,
485023

Enginuity Release Level 5876.286.194 Enginuity Service Pack ReadMe

15

Firmware Pack release history

Table 11
Release
date

Firmware packs release history (continued)

Full firmware pack file Firmware update file(s)

Description

OPT
numbers

10
December,
2015

fw_pack_full_151130 fw_151021_140913_SPH0020_HUS Updated Sunset Cove Plus drives to


firmware 1C04, and Seagate Lightning
_192500.exe
MH842.zip
fw_151021_140956_SPH0040_HUS 10K drives to firmware 700D.
MM144.zip
fw_151021_140959_SPH0080_HUS
MM148.zip
fw_151104_141743_LGHA030_ST3
00MM0.zip
fw_151104_141950_LGHA060_ST6
00MM0.zip
fw_151104_142007_LGHA090_ST9
00MM0.zip

485230,
487890

16 October,
2015

fw_pack_full_150929 fw_150924_122847.zip
_121255.exe
fw_150924_130829_CFHA030_HUC
10183.zip
fw_150924_130911_CFHA060_HUC
10186.zip
fw_150924_130920_CFHA090_HUC
10189.zip
fw_150924_130929_CFHA120_HUC
10181.zip

Updated HGST Cobra-F DriveDB


(revision 4406 includes 4402 but does
not include 4404), updated firmware
for HGST Cobra-F with capacity of
300GB, 600GB, 900GB and 1.2TB
(520bps).

477167,
481518

Updated the DriveDB revision to 4404


to enable BMS (Background Media
Scan) on Hitachi Viper-C drives.

484486

fw_pack_full_150910 fw_150910_192327.zip
16
September, _171301.exe
2015
11 June,
2015

fw_pack_full_150603 fw_150501_153529_A3HE030_AL1 Replaces previous Firmware pack


fw_pack_full_150519_110612.exe.
_162642.exe
3SXB3.zip
fw_150501_153623_A3HE045_AL1
3SXB4.zip
fw_150501_153627_A3HE060_AL1
3SXB6.zip
fw_150603_192431.zip

N/A

25 May,
2015

fw_pack_full_150519 fw_150501_153529_A3HE030_AL1 Added new drive support for Toshiba


AL13SX 15K 300GB, 450GB, and
_110612.exe
3SXB3.zip
fw_150501_153623_A3HE045_AL1 600GB SAS drives.
3SXB4.zip
fw_150501_153627_A3HE060_AL1
3SXB6.zip
fw_150501_154629.zip

465042,
475312

16

Enginuity Release Level 5876.286.194 Enginuity Service Pack ReadMe

Firmware Pack release history

Table 11
Release
date

Firmware packs release history (continued)


OPT
numbers

Full firmware pack file Firmware update file(s)

Description

16 January,
2015

fw_pack_full_150108 fw_140924_142243.zip
_135734.exe
fw_150107_210213.zip
fw_150108_161200_P4C0040_P40
0ECF4.zip
fw_150108_161316_P4C0020_P40
0ECF2.zip
fw_150108_161319_P4C0010_P40
0ECF1.zip
fw_150108_161322_P4C004I_P400
ECG4.zip
fw_150108_161324_P4C002I_P400
ECG2.zip
fw_150108_161327_P4C001I_P400
ECG1.zip
fw_150108_161329_CFHF030_HUC
15603.zip
fw_150108_161332_CFHF045_HUC
15604.zip
fw_150108_161334_CFHF060_HUC
15606.zip

Adding drive support for King Cobra-F


15K SAS 300 GB and 600 GB 2.5
drives.
Updated firmware for Micron Bear to
address response time/latency issues.

468126,
466154,
460570,
447889

15
December,
2014

fw_pack_full_141210 fw_141209_152926_VCFE030_HUS
_173547.exe
15603.zip
fw_141209_153014_VCFE045_HUS
15604.zip
fw_141209_153018_VCFE060_HUS
15606.zip

Updated firmware for Hitachi Viper-C


drives to mitigate rare case of poor
write failures on drives that have
remained idle for extended periods of
time.

466017

21
November,
2014

fw_pack_full_141118 fw_141117_221544_P4C0040_P40
_122305.exe
0ECF4.zip
fw_141117_221627_P4C0020_P40
0ECF2.zip
fw_141117_221634_P4C0010_P40
0ECF1.zip
fw_141117_221638_P4C004I_P400
ECG4.zip
fw_141117_221643_P4C002I_P400
ECG2.zip
fw_141117_221648_P4C001I_P400
ECG1.zip
fw_141117_221651_MPH7200_HU
S72402CLAR2000.zip
fw_141117_221657_MPH7300_HU
S72403CLAR3000.zip
fw_141117_221700_MPH7400_HU
S72404CLAR4000.zip

Addressed Micron Bear Assert issue,


where drives could become
unresponsive for a short period of time
because of insufficient resources for
wear leveling routines. This issue could
result in an increase in drive
replacements.
Added new drive support for Hitachi
Mars-K Plus 2TB, 3TB, and 4TB SAS
drives for Enginuity 5876

464627

Enginuity Release Level 5876.286.194 Enginuity Service Pack ReadMe

17

Firmware Pack release history

Table 11
Release
date

Firmware packs release history (continued)


OPT
numbers

Full firmware pack file Firmware update file(s)

Description

fw_pack_full_140918 fw_140808_141137_lgha030_st300
_180246.exe
mm0.zip
fw_140808_141151_lgha060_st600
mm0.zip
fw_140808_141205_lgha090_st900
mm0.zip

Updated firmware for Seagate Lightning


drives to address serial number
mismatch during Vault restores. The
following list shows the affected drives
and the new firmware version:
Seagate Lightning 300GB 10K,
2.5-inch SAS: 7004
Seagate Lightning 600GB 10K,
2.5-inch SAS: 7004
Seagate Lightning 900GB 10K,
2.5-inch SAS: 7004

460041

8
fw_pack_full_140903 N/A
September, _141025.exe
2014

Addressed a corruption issue that


prevents SymmWin from copying the
latest firmware drive code.

N/A

21 August,
2014

Updated firmware for Compass drives


to support 528BPS drives.
Updated drive firmware for Seagate
drives to address Read Look Ahead
(RLA) issue. The following list shows the
affected drives and the new firmware
version:
Seagate Compass: 2039
Eagle: EC13
Eagle RP: RC0B
Hurricane: HC0F
Lightning: 7007
Megalodon: 710A

451066

22
September
2014

18

fw_pack_full_140808 fw_140808_140811_hufe014_st31
_122723.exe
4635.zip
fw_140808_140831_hufe030_st33
0065.zip
fw_140808_140849_hufe045_st34
5085.zip
fw_140808_140904_erfa030_st330
060.zip
fw_140808_140917_erfa045_st345
080.zip
fw_140808_140926_erfa060_st360
000.zip
fw_140808_140934_egfe030_ste30
065.zip
fw_140808_140951_egfe045_ste45
085.zip
fw_140808_141002_egfe060_ste60
005.zip
fw_140808_141017_cpha090_st99
0080.zip
fw_140808_141029_cpha060_st96
0020.zip
fw_140808_141041_cpha030_st93
0060.zip
fw_140808_141054_mgh7100_st1
000nxclar1000.zip
fw_140808_141110_mgh7200_st2
000nxclar2000.zip
fw_140808_141120_mgh7300_st3
000nxclar3000.zip
fw_140808_141129_mgh7400_st4
000nxclar4000.zip
fw_140808_141137_lgha030_st300
mm0.zip
fw_140808_141151_lgha060_st600
mm0.zip
fw_140808_141205_lgha090_st900
mm0.zip

Enginuity Release Level 5876.286.194 Enginuity Service Pack ReadMe

Firmware Pack release history

Table 11
Release
date

Firmware packs release history (continued)

Full firmware pack file Firmware update file(s)

Description

OPT
numbers

26 June,
2014

fw_pack_full_140623 fw_140619_192328_CEHA030_HUC Updated firmware for Cobra-E drives to


support 528BPS drives.
_155652.exe
10903.zip
fw_140619_192336_CEHA060_HUC
10906.zip
fw_140619_192348_CEHA090_HUC
10909.zip

451063

6 June,
2014

fw_pack_full_140603 fw_140603_181224.zip
_155912.exe

Updated DriveDB for Hitachi Sunset


Cove and Seagate Megalodon 1TB
drives to resolve file revision conflicts.
NOTE: For full Sunset Cove Drive
support, fix 73840 is required.

445190,
436554

21 May,
2014

fw_pack_full_140516 fw_140305_115128.zip
_134651

Initial support for 1TB Seagate


Megalodon base drivedb.

436554

20 March,
2014

6
December,
2013

fw_140306_151152_MGH7100_ST1 Initial support for 1TB Seagate


000NXCLAR1000.zip
Megalodon drives with 7105 firmware.

435539

fw_140410_152240_RDH0010_SM1 Add support for Samsung RDX 100GB,


200GB, and 400GB drives with 33AB
62521.zip
fw_140410_152218_RDH0020_SM1 firmware.
62522.zip
fw_140410_152052_RDH0040_SM1
62524.zip

441609

fw_140515_191147_MKC7100_ST3 Updated firmware for Seagate


100C5CLAR1000.zip
Hardened Muskie 1TB and 2TB drives.
fw_140515_191257_MKC7200_ST3
200CPCLAR2000.zip

443697

Updated Seagate Yellowjacket firmware


to 2515 to address 528 format corrupt
issue on firmware download, and
updated Seagate Airwalker firmware to
260F for Mickey Cert fix.

440269

fw_140121_205426_100-886-019.z Added support for VMAX-1SE and


ip
VMAX-1 for the D15 LFE Disk Array
Enclosure (Part Number 100-886-019).

436701

fw_140127_081155_MPC7100_ST1 Updated Seagate Muskie Plus firmware


000NMCLAR1000.zip
to 23A1 for the 1TB drives and to 24A1
fw_140127_081211_MPC7200_ST2 for the 2TB drives.
000NPCLAR2000.zip

436940

fw_pack_full_140319 fw_140305_100003_YJHE014_ST91
_123927.exe
4685.zip
fw_140305_100031_YJHE030_ST93
0065.zip
fw_140313_100552_AWH7100_ST9
10006CLAR1000.zip

fw_pack_full_131205 fw_131119_100008_AWH7100_ST9 Updated drive firmware support for


Seagate Airwalker and Seagate
_134305.exe
10006CLAR1000.zip
fw_131119_100116_YJHE014_ST91 Yellowjacket Mickey Cert Fix.
4685.zip
fw_131119_100201_YJHE030_ST93
0065.zip

428896

fw_131119_095750_ALHE014_MK1 Added new firmware support for


401GR.zip
Toshiba AL12-SX drives.
fw_131119_095933_ALHE030_MK3
001GR.zip

Enginuity Release Level 5876.286.194 Enginuity Service Pack ReadMe

19

Firmware Pack release history

Table 11
Release
date

Firmware packs release history (continued)

Full firmware pack file Firmware update file(s)

Description

OPT
numbers

29 October,
2013

fw_pack_full_131025 fw_131016_054358_LGHA030_ST3 Added support for firmware 7004 for


Seagate Lightning 10K 300, 600, and
_100159.exe
00MM0.zip
fw_131016_054451_LGHA060_ST6 900GB drives.
00MM0.zip
fw_131016_054500_LGHA090_ST9
00MM0.zip

425193

25 October,
2013

fw_pack_full_131025 fw_131016_084302_ERFA045_ST34 Added firmware updates for Hurricane


(HC0E), Eagle (EC11), Eagle RP (RC0A),
_093759.exe
5080.zip
fw_131016_084306_ERFA060_ST36 and Ralston Peak (C200) drives.
0000.zip
fw_131016_084320_EGFE060_STE6
0005.zip
fw_131016_084325_PKF0010_HUS
SL401.zip
fw_131016_084330_PKF0020_HUS
SL402.zip
fw_131016_084334_PKF0040_HUS
SL404.zip
fw_131016_084142_HUFE014_ST3
14635.zip
fw_131016_084248_HUFE030_ST3
30065.zip
fw_131016_084253_HUFE045_ST3
45085.zip
fw_131016_084257_ERFA030_ST33
0060.zip
fw_131016_084311_EGFE030_STE3
0065.zip
fw_131016_084316_EGFE045_STE4
5085.zip

425838

7 October,
2013

fw_pack_full_131004 fw_131004_165608.zip
_135048.exe

Added support for Airwalker and Yellow


Jacket drives to separate Directed
Offline Scan (DOS) entries from
Background Media Scan (BMS) entries
on page 15, and increased Grown Block
threshold on Yellow Jacket drives.

FW OPT:
428079
SR OPT:
424406

30 July,
2013

fw_pack_full_130730 fw_130730_151320.zip
_141600.exe

New drive support added for Samsung


RDX.

FW OPT:
424573
SR OPT:
422589

18 July,
2013

fw_pack_full_130718 fw_130716_202110_071-000-518.z Added support to the parts file for the


ip
VMAX-V1/20k to all of the D15 LFE
_100834.exe
fw_130716_202112_071-000-553.z power supplies.
ip
fw_130716_202112_071-000-554.z
ip

FW OPT:
423967
SR OPT:
423376

9 July, 2013 fw_pack_full_130709 fw_130705_101343.zip


_134651.exe

20

Enginuity Release Level 5876.286.194 Enginuity Service Pack ReadMe

Added drive support for Toshiba


AL12-SX, updated mode pages for
Compass SAS drives, and updated
Megalodon Product IDs.

FW OPT:
423445
SR OPT:
417499

Firmware Pack release history

Table 11
Release
date

Firmware packs release history (continued)

Full firmware pack file Firmware update file(s)

Description

OPT
numbers

3 July, 2013 fw_pack_full_130703 fw_130703_103524_MGH7200_ST2 Added firmware 7105 to support


Seagate Megalodon 2, 3, and 4TB
_125507.exe
000NXCLAR2000.zip
fw_130703_103524_MGH7200_ST2 drives.
000NXCLAR3000.zip
fw_130703_103524_MGH7200_ST2
000NXCLAR4000.zip

FW OPT:
423356
SR OPT:
421430

24 June,
2013

24 April,
2013

fw_pack_full_130624 fw_130620_175834_071-000-554.zi
_102956.exe
p

Added DAE Power Supply support.

FW OPT:
422727
SR OPT:
422250

fw_pack_full_130624 fw_130613_082355.zip
_101505.exe

Added 4TB SymmWin support.

FW OPT:
422576
SR OPT:
410835

fw_pack_full_130424 fw_130423_150134_MON7100_ST31 Added firmware 2102 to add BMS


_152259.exe
0003CLAR1000.zip
support for Seagate Moose.

FW OPT:
420205
SR OPT:
418820

Enginuity Release Level 5876.286.194 Enginuity Service Pack ReadMe

21

Troubleshooting and getting help

Troubleshooting and getting help


EMC support, product, and licensing information can be obtained at EMC Online Support.
Note: To open a service request through EMC Online Support, you must have a valid
support agreement. Contact your EMC sales representative for details about obtaining a
valid support agreement or to answer any questions about your account.

Product information
For documentation, release notes, software updates, or for information about EMC
products, licensing, and services, go to EMC Online Support (registration required) at:
https://support.EMC.com

Technical support
EMC offers a variety of support options.
Support by Product EMC offers consolidated, product-specific information on the Web
at:
https://support.EMC.com/products
The Support by Product web pages offer quick links to documentation, white papers,
advisories (such as frequently used Knowledgebase articles), and downloads. It also
provides more dynamic content, such as: presentations, discussions, relevant Customer
Support Forum entries, and a link to EMC Live Chat.
EMC Live Chat Open a Chat or instant message session with an EMC Support Engineer.
VMAX Family System Viewer Illustrates the system hardware, incrementally scalable
system configurations, and available host connectivity offered for VMAX and VMAX 3
systems. To download this standalone utility, go to EMC Online Support.

eLicensing support
To activate your entitlements and obtain your Symmetrix license files, visit the Service
Center on https://support.EMC.com, as directed on the License Authorization Code (LAC)
letter e-mailed to you.
For help with missing or incorrect entitlements after activation (that is, expected
functionality remains unavailable because it is not licensed), contact your EMC Account
Representative or Authorized Reseller.
For help with any errors applying license files through Solutions Enabler, contact the EMC
Customer Support Center.
If you are missing an LAC letter, or require further instructions on activating your licenses
through EMC Online Support, contact EMC's worldwide Licensing team at
licensing@emc.com or call:

22

North America, Latin America, APJK, Australia, New Zealand: SVC4EMC


(800-782-4362) and follow the voice prompts.

EMEA: +353 (0) 21 4879862 and follow the voice prompts.

Enginuity Release Level 5876.286.194 Enginuity Service Pack ReadMe

Troubleshooting and getting help

Copyright 2016 EMC Corporation. All rights reserved. Published in the USA.
Published April, 2016
EMC believes the information in this publication is accurate as of its publication date. The information is subject to change without
notice.
The information in this publication is provided as is. EMC Corporation makes no representations or warranties of any kind with
respect to the information in this publication, and specifically disclaims implied warranties of merchantability or fitness for a
particular purpose. Use, copying, and distribution of any EMC software described in this publication requires an applicable software
license.
EMC2, EMC, and the EMC logo are registered trademarks or trademarks of EMC Corporation in the United States and other countries.
All other trademarks used herein are the property of their respective owners.
Enginuity Release Level 5876.286.194 Enginuity Service Pack ReadMe

23