The document describes the procedures for using four pieces of equipment in a blood bank: a tube sealer, plasma thawer, refrigerated centrifuge, and blood bank refrigerator. The tube sealer is used to seal blood bags and includes steps like ensuring the electrode cover is in place and holding the tube between the sealing electrodes. The plasma thawer allows plasma to thaw quickly and safely through programmed defrosting times. The refrigerated centrifuge can run multiple blood separation programs simultaneously and has safety alarms. The blood bank refrigerator stores blood and plasma at regulated temperatures between 2-6 degrees Celsius.
The document describes the procedures for using four pieces of equipment in a blood bank: a tube sealer, plasma thawer, refrigerated centrifuge, and blood bank refrigerator. The tube sealer is used to seal blood bags and includes steps like ensuring the electrode cover is in place and holding the tube between the sealing electrodes. The plasma thawer allows plasma to thaw quickly and safely through programmed defrosting times. The refrigerated centrifuge can run multiple blood separation programs simultaneously and has safety alarms. The blood bank refrigerator stores blood and plasma at regulated temperatures between 2-6 degrees Celsius.
The document describes the procedures for using four pieces of equipment in a blood bank: a tube sealer, plasma thawer, refrigerated centrifuge, and blood bank refrigerator. The tube sealer is used to seal blood bags and includes steps like ensuring the electrode cover is in place and holding the tube between the sealing electrodes. The plasma thawer allows plasma to thaw quickly and safely through programmed defrosting times. The refrigerated centrifuge can run multiple blood separation programs simultaneously and has safety alarms. The blood bank refrigerator stores blood and plasma at regulated temperatures between 2-6 degrees Celsius.
Blood bag tube thermosealers are used to seal the pilot tubing of bags used to collecting and processing blood. Some designs include radio frequency systems that can seal a tube in less than 2 or even 1 second, without causing hemolysis or leakage. Blood bag tube thermosealers are available as both hand-held and bench top devices. Procedure: 1. Ensure that the electrode cover is in position. 2. Turn ON the power switch. Power and Ready LEDS will glow. 3. Hold the tube at both ends and place the tube in between the sealing electrodes through the slot provided in the electrode cover. 4. The tube detection lever gets depressed in this process. Moving electrode pushes the tube against the fixed electrode. Seal LED turns ON. Tube melts and the sealed pattern forms. 5. Do not stretch the tube while sealing. This may cause leakage. 6. After a time delay, the electrode will release. Seal LED goes OFF. 7. Take out the sealed tube. 8. Turn off the power switch.
Presvac Plasma Soft
- Allows the plasma to thaw quickly and safely and heating of blood products. - Programmable defrosting time for each unit. - Capacity of 8 units of plasma from 50-450 ml - Panel with LCD viewer Procedure: 1. Turn ON the power switch. 2. Set the time at the designated racks where the fresh frozen plasma or cryoprecipitate will be placed. 3. Wait for the temperature to reach 37 degrees celsius before placing the plasma. 4. Thawing time is finished when the alarm goes off. 5. Remove the thawed plasma.
6. Turn off the power switch.
Presvac MSP 4650R Refrigerated Centrifuge
- Motor high performance centrifuge brushless with free maintenance - Program up to 50 alphanumeric programs with all the variables of time, speed, temperature, braking, acceleration, program name, run command and detention - Programmable electronic timer with automatic stop, up to four bags of 500 ml quadruple, triple, double and platelets obtained by method of Buffy Coat. Security system with optical and sound alarms for imbalance and open lid that interrupts the run with automatic detention.
Blood Bank Refrigerator
Blood bank refrigerators keep blood and plasma at temperatures between 2 degrees Celsius and 6 degrees Celsius, so that they are constantly prepared for emergency transfusions. Blood bank refrigerators utilize stringent security measures to prevent tampering. Procedure: 1. 2. 3. 4.
Refrigerator is installed in setting of use.
Line power is plugged in. When refrigerator reaches desired temperature, it is safe to use. Laboratory staff should continuously monitor the temperature of the refrigerator.
Immunology and Serology
& Blood Bank (Written Report) Submitted by: Bernales, Ma. Isabelle Diata Cruz, Christine Airah M. Gaba, Christian Joy Sena, Jenz Lou