Академический Документы
Профессиональный Документы
Культура Документы
Infiltration modules
Infiltration filters
Edition 2008
Brochure V 28 EN
s h a f t s a n d A c c e ss o r i e s
Owner: .................................................................
Name: ..................................................................
Street: .................................................................
Post code/city: ...................................................
Tel.: .......................................................................
Fax: .......................................................................
e-mail: .................................................................
Residential
Industrial/Commercial
Local Authority
............................................
Recommended median flow values according to ATV-DVWK-A 117 and ATV-DVWK-M 153 (German standards)
Area type / roof
Type of fixing
Pitched roof
0,9-1,0
0,9-1,0
0,9
Roofing cardboard
0,7
Flat roof
(Pitch up to 3 or approx. 5%)
Gravel
0,7
Green roof
(Pitch up to 15 or approx. 25%)
0,5
0,3
0,9
0,75
0,6
0,5
0,3
0,25
Honeycomb bricks
0,16
Clayey soil
0,5
0,4
0,3
Flat site
0,0-0,1
Steep site
0,1-0,3
Kf (m/sec)
Gravel
1*10-3
Medium sand
1*10-4
Fine sand
1*10-5
Coarse clay
1*10-6
Clay
1*10-7
m surface
No infiltration possible
x
Please send us the completed form. We will calculate your necessary infiltration volume and create a free quotation.
Internationally proven:
GRAF infiltration modules
Infiltration Tunnel
Rain Bloc
Stormwater management
know-how of GRAF
Retention cisterns
ppy
ld be ha ct.
u
o
w
e
W
oje
your pr
to size
!
ll
a ca
Give us
Gravel
Sand
Clay
Type of soil
Gravel
Medium sand
Fine sand
Coarse clay
Clay
Percolability
150 litres
200 litres
150 litres
200 litres
150 litres
200 litres
150 litres
200 litres
100m
150m
200m
number GRAF modules
3
5
6
7
8
10
10
13
4
7
8
11
12
15
15
19
No infiltration possible
5
8
10
14
15
20
19
25
95%
less excavation
Easy to install
Installing the module is easy, fast and
variable. It can be installed without
heavy equipment - a Rain Bloc weighs just
15kg. The individual modules are connected
using practical fast connectors.
of
pipe!
more excavation
Retention cisterns
30%
. 800kgge
x
o
r
p
p
a
a
Replacl eosr 36m drain
e
grav
Cost-effective
Infiltration Tunnel
30%
95%
7
High-performance
The lorry-bearing design guarantees
extreme load capacity thanks to its stable
column structure. It facilitates SLW 60bearability with an 800mm (31.5 inches)
covering. The vehicle loading design can
bear a long-term load of approx. 3.5t per
m. There are no limits on the use and
design of the surface over the system.
Inspectable
Easy to install
Length
[mm]
Width
[mm]
Height
[mm]
Colour
Order no.
Vehicle loading
Lorry-bearing
1,200
1,200
600
600
420
420
green
black
360011
360010
Length
[mm]
Width
[mm]
Height
[mm]
Colour
Order no.
Lorry-bearing
1,200
600
420
black
360013
Inspection end
DN 100
Order no. 202004
Item
Connecting elements
for all horizontal
and vertical connections 10 units
Order no. 369012
Rain Bloc
GRAF-Tex geotextile
for a Rain Bloc size of 2.50 x 2.50m
Order no. 369010
Pedestrian*
*Details see page 11
25cm
50-80cm
Retention cisterns
25cm
Vehicle loading*
Lorry-bearing*
up to 60 tons total weight
Choice of position
Installation
of the Rain Bloc
The impermeable membrane is put on the
horizontal, flat footprint of the excavation
with 500mm (19.7 inches) overlapping. The
modules are positioned horizontally on the
membrane and connected with each other
by plastic connectors. For lengthwise and
crosswise connection each 4 connectors are
necessary. For systems with various layers,
the different layers must show an alternate
arrangement of lengthwise and crosswise
layers to obtain maximum stability. Before
the excavation is filled with material, all the
modules must be wrapped completely with
fleece, whereas the ends of each fleece line
must have an overlap of at least 500mm
(19.7 inches). After that the excavation is
filled in layers and constantly compressed.
Front view
DN 100/125/150
Technical data
Volume
300 Litres (79 US-gallons)
Length
1200mm (47.2 inches)
Width
600mm (23.6 inches)
Height
420mm (16.5 inches)
Connectors
12 x DN 150
6 x DN 125
6 x DN 100
Weight
approx. 15 kilos
Material
Side view
420mm
(16,5 inches)
10
max. 7,5t/m
max. 3,5t/m
max. 10t/m
max. 5t/m
Lorry-loading 12 t
Short-term
Long-term
Infiltration Tunnel
Load
Rain Bloc
Excavated material
Rain Bloc
GRAF-Tex geotextile
Retention cisterns
Water-resistant film
GRAF-Tex geotextile
Vehicle loading
For offering versatile possibilities
of utilisation, the surface beyond
the infiltration tunnels can
be loaded permanently up to
3.5tons/sqm and thus is also
suitable for vehicle loading.
12
Easy installation
The GRAF Infiltration Tunnels are laid in
lines and can be flexibly adapted to specific
conditions and to the individual storage
volume requested. The installation of the
modules is easy, quick and variable.
The installation is possible without heavy
equipment, as one infiltration tunnel only
weighs 11 kilos. The tunnel modules are
simply stuck together in one line and
equipped with 2 end plates per line.
Rain Bloc
Item
Length
[mm]
Width
[mm]
Height
[mm]
Colour
Order no.
Vehicle loading
1,220
800
510
black
410097
Colour
black
Order no.
410098
Inspection end
DN 200
Order no. 340527
Deaeration end
DN 100
Order no. 202004
GRAF-Tex geotextile
For an Infiltration Tunnel size
of 1.50 x 2.50m
Order no. 369026
50cm
Retention cisterns
30cm
Pedestrian
*Details see page 15*
Vehicle loading*
13
Choice of position
The distance of the ditch to adjacent
buildings for non-sealed up cellars has to be
at least 6metres (236.2 inches). The GRAF
Infiltration Tunnel has to be installed with
at least 39.4 inches space to the groundwater. The distance to existing or planned
tree population must correspond at least to
the (expected) diameter of the crown.
The horizontal, flat footprint of the excavation first has to be filled with a layer of
gravel (approx. 10cm (3.9 inches), grain size
8/16) which serves as granular sub-grade
course.
The infiltration tunnels are put on the
gravel pit and connected with each other
in lines (lengthwise). In order to protect
the infiltration tunnel from silt etc. they
are wrapped round by filter fleece and thus
being separated from the filling material.
The filter fleece should overlap the end of
the modules by at least 30cm (11.8 inches).
Afterwards the excavation will be filled
steadily and in layers.
Side view
Front view
Technical Data
Volume
300 litres (79 US-Gallons)
Length
490mm
510mm
(19.3 inches) (20.8 inches)
Width
Height
Connectors
Weight
approx. 11kg
Material
DN 200
400mm
(15.8 inches)
End plate
Plan view
DN 200
DN 100
DN 100
DN 150
DN 200
DN 300
800mm
(31.5 inches)
DN 100
End plate, order no. 231004
14
Rain Bloc
Plan view
Car footprint
Infiltration Tunnel
Filling material
Geo grid (optional)
Filling material: top soil/sand mixture
with coefficient value 1 x 10 -5 m/s
Geotextile (e.g. GRAF-Tex)
Gravel 20/40
Infiltration Tunnel
Inflow pipe max. DN 300
Geo grid
(optional)
Inspection/
deaeration end
Car
footprint
Gravel 20/40
Section infiltration
system
Inflow channel
100mm (4 inches)
GRAF-Tex geotextile
Infiltration Tunnel
Road or
parking space
GRAF-Tex geotextile
Retention cisterns
11
15
Swale-Ditch infiltration
The infiltration through swale-ditches can
be realised independently from the soil
condition. According to the soils infiltration
performance the attention can be either
turned on infiltration or on retention.
Infiltration Tunnel
cleaning process
Coarse filter insert
2 Fine filter basket (0.35mm mesh width)
3 Sedimentation zone
l Keeps back dirt that may impair the
infiltration performance
l Ideal as a yard inlet or as a basin
infiltration ditch element
l Vehicle loading with cast cover category B
l Continuously adjustable mounting depth
of 570mm (22.4inches) -1,050mm
(41.3inches) through telescope dome shaft
1
To infiltration
Infiltration filter shaft
Vehicle loading, colour: black
Order no. 340025
Emergency
overflow
Overfow
to channel
Choke adjustable
16
l Drain
Infiltration filters
Emergency
overflow
Overfow
to channel
Cleaned water to
tank or to infiltration
l 3-stage
cleaning process
fine filter basket (0.35mm mesh width)
2 sedimentation zone
3 dip tube as oil separator
l Continuously adjustable mounting depth
of 900mm (35.4 inches) -1,600mm
(63 inches) through telescope dome shaft
600mm (23.6 inches)
l Plastic cover can be walked on or cast
cover can be driven on by car
l Cover childproof lockable
l Sealed up to earths surface
l Max. 1,000sqm of sealed area
to be connected
l Connections DN 150
l 100%
Sedimentation filter shaft
Suitable for pedestrian loading,
colour: green
Order no. 340026
Sedimentation filter shaft
Suitable for vehicle loading,
colour: black
Order no. 340027
water yield
adjustable mounting depth
of 800mm (31.5 inches) -1,200mm
(47.2 inches) through telescope dome
shaft
l Plastic cover can be walked on or cast
cover can be driven on by car
l Cover childproof lockable
l Little height offset (270mm / 10.6inches)
between inlet and outlet
l Maximally 350sqm roof surface with
DN 100 connections and 500sqm with
DN 150
l Connections DN 100 and DN 150
l Sieve insert with 0.35mm (0.14 inches)
mesh width
l Continuously
l Specifications
as Universal-Filter
3 external
roof surfaces up to 1,200sqm
l Continuously adjustable mounting depth
of 800mm (31.5 inches) -1,200mm
(47.2inches) through telescope dome
shaft 600mm (23.6inches)
l Maximally 750sqm roof surface with
DN 150 connections and 1,200sqm
with DN 200
l Connections DN 150 and DN 200
l Sieve insert with 0.35mm mesh width
l For
Retention cisterns
Outflow to
infiltration
Cleaned water
to tank
Infiltration Tunnel
17
Technical data
Capacity
1,600 Litres (423 US-gallons)
Min.
1,090mm (43 inches)
Max.
1,350mm (53 inches)
Height
1,600mm (63 inches)
Material fibre-glass reinforced PP
(UV stable and
100% recyclable)
Weight
approx. 60kg
Connections each 2 x DN 70,
DN 100 and DN 200
for standard pipe
Tank dome
(with telescopic end 1m (39.3 inches),
to be cut on request),
DN 200
Order no. 202033
GRAF-Tex geotextile
For one Herkules Infiltration Tank
Order no. 202005
Material sold by the metre, roll width 5m
(196.9 inches)
Order no. 322009
Advantages:
Ease of transport
Each tank half weighs only 30kg, which allows for ease of transport
and manual assembly. The individual components can fit through any
standard doorway. (more
than 80cm/
31.5inches)
18
Tank combinations
With the use of standard interconnection pipes, multiple tanks can be combined to make
up large total
storage volumes as required
Universal Shaft
l Universal
l Many
l Many
Shaft T 220 (without bottom)
Suitable for pedestrian loading
Order no. 340527
Shaft T 400 (without bottom)
Suitable for pedestrian loading
Order no. 330132
Shaft
Outside
[mm]
Inside
[mm]
Height
[mm]
T 220
T 400
T 600
273
550
850
206
400
600
250
500
475
Shaft T 400 (with bottom)
Suitable for pedestrian loading
Order no. 330133
Shaft T 600 (with bottom)
Suitable for pedestrian loading
Order no. 330155
Non-return valve
prevents waste water
seeping back into the tank
from the sewer
Best.-Nr. 331014
Dimensions mm
Retention cisterns
to the tank
to the sewer
Variable
connection
options
Infiltration Tunnel
Rain Bloc
Universal shafts
19
Emergency overflow
Max. water level
(short term)
Floating choke
drain
Rainwater
retention
Sewer or
infiltration
2,700
3,750
4,800
6,500
7,500*
9,600*
13,000*
Total volume
[US-gal]
700
1,000
1,250
1,700
2,000
2,500
3,400
Retention volume
[ltrs]
2,700
3,750
4,800
6,500
7,500
9,600
13,000
Retention volume
[US-gal]
Lorry-bearing
Order no.
700
1,000
1,250
1,700
2,000
2,500
3,400
370500
370501
370502
370503
370506
370507
370508
Total volume
[ltrs]
Storage volume
holds
20
As an alternative to pure rainwater retention, a retention cistern can also be used for
rainwater harvesting. The water level here
can also rise to the emergency overflow and
sink slowly back down again after the rain
to the long-term max. water level. However,
the long-term max. water level is chosen so
that part of the tanks volume can be used
for rainwater harvesting.
Emergency overflow
Overflow
siphon
Rainwater
harvesting
4,800*
6,500
6,500
7,500*
7,500*
9,600*
9,600*
13,000*
13,000*
Total volume
[US-gal]
1,250
1,700
1,700
2,000
2,000
2,500
2,500
3,400
3,400
Retention volume
[ltrs]
2,000
3,000
2,000
4,000
3,000
4,000
3,000
4,000
3,000
Retention volume
[US-gal]
Lorry-bearing
Order no.
520
780
520
1,050
780
1,050
780
1,050
780
370520
370521
370522
370527
370528
370529
370530
370531
370532
ver your
and deli s.
t
c
ru
t
s
con
tion
We also ual special solu veral
se
d
n
a
individ
ion
,200
tween 2 ponding retent
e
b
s
e
iz
s
S
e
rr
o
c
s
u
h
ltrs wit
Contact
100,000 s are possible.
you!
t
is
s
s
e
a
volum
ppy to
ld be ha
we wou
Sewer or
infiltration
Rainwater
retention
Settled inlet
Infiltration Tunnel
Floating choke
drain
Total volume
[ltrs]
Rain Bloc
Retention cisterns
Retention cisterns
l Tank
21
Stormwater Management
Rainwater Harvesting
Prices:
A price list with our export conditions is available on
request.
Warranty clause:
The warranty mentioned in this brochure only refers to
the tank in question and not to the accessories. Within
the warranty period we grant free replacement of the
material. Further benefits are excluded. Pre-condition
for warranty benefits are proper handling, assembly and
installation according to the mounting guidelines.
Infiltration
a G R I CULTURAL C o n t a i n e r s
45
Over
years
of quality and
innovation