NAME
[[RELAY SETUP]]
<PORT SETTING>
- RS232-1 Line Speed (bps)
Parity Bit
Data Bit
Stop Bit
Line Type
CTS function
DCD function
RTS function
CTS Check-Out Time (sec)
DCD Time-out (msec)
TX Post delay (msec)
TX Pre Delay (msec)
- RS232-2 Line Speed (bps)
Parity Bit
Data Bit
Stop Bit
Line Type
CTS function
RTS function
DCD function
CTS Check-Out Time (sec)
DCD Time-out (msec)
TX Post delay (msec)
TX Pre Delay (msec)
- ETHERNET IP Address 1
IP Address 2
IP Address 3
IP Address 4
Gateway Address 1
Gateway Address 2
Gateway Address 3
Gateway Address 4
Subnet Mask
Keep-Alive Function
Keep-Alive Idle Timeout (sec)
Keep-Alive Probe Interval (sec)
keep-Alive Probe Retry Count
<COMMUNICATION>
- DNP3.0 (1) Function
Use Port
Master Address
Slave Address
D/L Confirm
D/L Retries
D/L Timeout
A/L Retries
A/L Timeout
SBO Time (sec)
Multiframe Interval (sec)
PowerUp Unsol
Unsol Time (sec)
Unsol Type
Class 1
Page : 1
VALUE
19200
NONE
8
1
2
ON
OFF
AUTO
5
5000
50
5
19200
NONE
8
1
2
ON
AUTO
OFF
5
5000
50
5
0
0
0
0
0
0
0
0
255.255.255.000
DISABLE
4
2
1
DISABLE
P2-232
60000
1
SOME
2
55
1
55
15
0.10
ENABLE
5
NOTRIG
DISABLE
Saved
Page : 2
VALUE
DISABLE
DISABLE
0
0
0
0
TCP
20000
20000
10
2048
1440
DISABLE
P3-232
60000
2
SOME
2
55
1
55
15
0.10
ENABLE
5
NOTRIG
DISABLE
DISABLE
DISABLE
0
0
0
0
TCP
20000
20000
10
2048
1440
DISABLE
P4-TCP
1
0.005
TCP
502
502
DISABLE
P2-232
1
1
60
15
0
15
60
2
Saved
Page : 3
VALUE
ALWAYS
1
261
15
261
1
2
NO
30
5
YES
YES
YES
DISABLE
1
60
120
15
10
20
5
2404
255
255
5
YES
YES
YES
OFF
YES
YES
ALL
256
ALL
256
ALL
256
10V
10K
NO
NO
LOCAL
LOCAL
YES
TYPE2
ON
4
ON
15
GMT
+
0
0
Saved
VALUE
Display Type
YMD
Function
Relays (0000~8888)
Counter for Alarm
Counter Set
- BATTERY TEST Battery Test Interval
<GAS LOW>
- GAS LOW LOCK Function
<FAULT LOCATOR>
- FAULT LOCATOR Function
Length of Feeder (km)
Z1-Resistive (ohms)
Z1-Inductive (ohms)
Z0-Resistive (ohms)
Z0-Inductive (ohms)
<DEMAND>
- DEMAND Function
Relays (0000~8888)
Type
Time Constant (min)
Pickup-Phase
Pickup-Ground
Pickup-NEG
<RECLOSER WEAR>
- RECLOSER WEAR Function
Pickpu Wear Level (%)
Rated Voltage (kV)
Interrupt Rating (kA)
Number of Max Intrpt
Wear Set-A Phase (%)
Wear Set-B Phase (%)
Wear Set-C Phase (%)
<SYNCHRO CHECK>
- SYNCHRO CHECK Function
Relays (0000~8888)
Dead Line Max. Voltage
Live Line Min. Voltage
Max. Volt Difference
Max. Angle Difference (deg)
Max. Freq' Difference (Hz)
Synchrocheck Phase
<EXT'TRIP LOCK>
- EXT'TRIP LOCK Function
Use Input Port
Reset Method
<LIVE LOAD BLOCKING>
- LIVE LOAD BLOCKING Function
OFF
0000
10000
28
[[MONITORING SETUP]]
<TRIP/BATTERY TEST>
- TRIP COUNTER -
Page : 4
0000
DISABLE
OFF
50.0
10.0
10.0
10.0
10.0
OFF
0000
THM
5
600
300
600
ALARM
20.0
27
12.5
100
100.00
100.00
100.00
OFF
0000
0.50
0.85
0.10
15
2.00
R(AB)
DISABLE
1
LOCAL ONLY
OFF
Saved
VALUE
0.30
1.00
<FAULT ALARM>
- FAULT ALARM Function
Pickup delay
Dropout delay
[[SYSTEM SETUP]]
<SYSTEM>
- CURRENT SENSING Phase CT Ratio
Ground CT Ratio
SEF CT Ratio
- LINE VS SENSING Connect Type
VT 2nd (V)
VT Ratio
- LINE VL SENSING Connect Type
VT 2nd (V)
VT Ratio
Install Type
- SYSTEM POWER Frequency
Phase Rotation
Install Direction
Phase Combination
- AUTO SETTING GROUP CHANGE Function
Time (sec)
- PANEL SLEEP TIME Interval (min)
<LOOP CONTROL>
- LOOP CONTROL Select recloser type
VRS at Sec Mid
VRS to Tie
VS Wire
VL Wire
Auto Change to Alt' Setting - MID
Auto Change to Alt' Setting - Tie
LC Action after Manual Close
LC Action after Manual Open
Open Time on Both Dead Line (sec)
Auto Restoration Time (sec)
Dead Line Max. Voltage (xVT)
Live Line Min. Voltage (xVT)
Dead Line Picup Time (sec)
LIve Line Regain Time (sec)
Dead Line Reset Time (sec)
Non Reclose Time after LC Act. (sec)
<OPTO INPUT SET>
- INPUT 1 Function
Debounce Time (sec)
- INPUT 2 Function
Debounce Time (sec)
- INPUT 3 -
Page : 5
DISABLE
0.02
0.02
400
400
400
CVD-W
84.8
155.9
CVD-W
84.8
155.9
3P
60
ABC
NOR
abc
DISABLE
30
5
NONE
VS
VS
3PN
3PN(NA)
OFF
OFF
DISABLE
DISABLE
10.00
5.00
50.0
70.0
50.00
10.00
5.00
10.00
NONE
0.02
NONE
0.02
Saved
Page : 6
VALUE
NONE
0.02
NONE
0.02
NONE
0.02
NONE
0.02
NONE
0.02
NONE
0.02
NONE
S/R LATCH
0.05
NONE
S/R LATCH
0.05
NONE
S/R LATCH
0.05
NONE
S/R LATCH
0.05
NONE
S/R LATCH
0.05
NONE
S/R LATCH
0.05
NONE
S/R LATCH
0.05
NONE
S/R LATCH
0.05
DISABLE
60
DISABLE
0.80
5
Saved
VALUE
DISABLE
1.20
5
Page : 7
DISABLE
30
4.0
10
DISABLE
30
4.0
OFF
GND
MANUAL
0.00
OFF
300
0.20
NO
OFF
135
0.20
NO
OFF
135
0.20
NO
OFF
135
0.20
NO
2
2
2
4
2
2
2
0.40
1.50
15.00
15.00
30.00
10.00
60.00
Saved
VALUE
Phase
Ground
S.E.F
NEG Seq
20
10
8
OFF
<PHASE/GND/SEF/NEGATIVE>
- PHASE FAST Curve Preview
Function
Relays (0000~8888)
Curve
Time Dial
Time Adder (sec)
Min. Res' Time (sec)
Reset Method
Low Set DT (sec)
- PHASE DELAY Curve Preview
Function
Relays (0000~8888)
Curve
Time Dial
Time Adder (sec)
Min. Res' Time (sec)
Reset Method
Low Set DT (sec)
- GROUND FAST Curve Preview
Function
Relays (0000~8888)
Curve
Time Dial
Time Adder (sec)
Min. Res' Time (sec)
Reset Method
Low Set DT (sec)
- GROUND DELAY Curve Preview
Function
Relays (0000~8888)
Curve
Time Dial
Time Adder (sec)
Min. Res' Time (sec)
Reset Method
Low Set DT (sec)
- SEF Function
Relays (0000~8888)
Time Delays (sec)
- NEGATIVE FAST Curve Preview
Function
Relays (0000~8888)
Curve
Time Dial
Time Adder (sec)
Min. Res' Time (sec)
Page : 8
TRIP
0000
IEC-EI
0.05
0.00
0.00
INST
OFF
TRIP
0000
IEC-EI
0.05
0.00
0.00
INST
OFF
TRIP
0000
IEC-EI
0.05
0.00
0.00
INST
OFF
TRIP
0000
IEC-EI
0.05
0.00
0.00
INST
OFF
TRIP
0000
1.00
TRIP
0000
ANSI-STI
0.50
0.00
0.00
Saved
Page : 9
VALUE
INST
OFF
TRIP
0000
ANSI-VI
3.00
0.00
0.00
INST
OFF
TRIP
0000
400
0.10
1
TRIP
0000
300
0.10
1
OFF
0000
4000
0.00
OFF
TRIP
0000
600
0.00
1
TRIP
0000
450
0.00
1
OFF
0000
8000
0.00
OFF
TRIP
0000
NO
2000
2000
20
2000
Saved
VALUE
10.00
5.00
ON
ON
ON
ON
0.60
OFF
10
<VOLTAGE>
- UNDER VOLTAGE 1 Function
Relays (0000~8888)
Pickup
Time Delay (sec)
Min. Voltage
Pickup Type
- UNDER VOLTAGE 2 Function
Relays (0000~8888)
Pickup
Time Delay (sec)
Min. Voltage
Pickup Type
- OVER VOLTAGE 1 Function
Relays (0000~8888)
Pickup
Time Delay (sec)
Pickup Type
- OVER VOLTAGE 2 Function
Relays (0000~8888)
Pickup
Time Delay (sec)
Pickup Type
<FREQUENCY>
- FREQUENCY Function
Relays (0000~8888)
Under Pickup (Hz)
Under Trip Time Delay (sec)
Over Pickup (Hz)
Over Trip Time Delay (sec)
Min. Voltage
Min. Current
Normal Frequency Close Function
Normal Frequency Close Time Delay (sec)
<USER CURVE>
- USER CURVE 1 Factor a
Factor b
Factor r
Factor rt
- USER CURVE 2 Factor a
Factor b
Factor r
Page : 10
OFF
0000
0.70
5.00
0.10
1P
OFF
0000
0.70
5.00
0.10
1P
OFF
0000
1.20
5.00
1P
OFF
0000
1.20
5.00
1P
OFF
0000
45.00
2.00
55.00
6.00
0.10
10
OFF
60.0
59.5000
2.0000
1.8000
59.5000
39.8500
2.0000
0.9500
Saved
VALUE
39.8500
Factor a
Factor b
Factor r
Factor rt
59.1000
2.0000
0.3450
59.1000
Factor a
Factor b
Factor r
Factor rt
5.6700
2.0000
0.0352
5.6700
Function
Relay (0000~8888)
Pickup
Time Delay (sec)
OFF
0000
0.30
20.00
- USER CURVE 3 -
- USER CURVE 4 -
<LOSS OF PHASE>
- Loss Of Phase -
<ALARM CURRENT>
- ALARM CURRENT Pickup-Phase
Pickup-Ground
Pickup-SEF
Pickup-NEG
Pickup-Time
Dropout Time
Page : 11
OFF
OFF
OFF
OFF
1.00
1.00
Saved