2223 Transmitter for

Servomex 2200 Process Oxygen Solution

The 2223 paramagnetic oxygen transmitter is specifically designed for high performance
measurements in the process industry.
Servomex oxygen specific, field proven paramagnetic technology
Unrivalled accuracy, reliability, stability and repeatability
Certified for hazardous areas, flammable dust and flammable gases
Compliant with the requirements of NAMUR
Simple transmitter only operation or in conjunction with control unit
Hazardous Area Approvals:
ATEX Category 2
CENELEC Zone 1
FM Class I, Division 1
CSA Class I, Division 1
TIIS Zone 1
IECEx Zone 1
The transmitter has been designed for use on process control applications, such as, the
manufacture of ethylene oxide, propylene oxide, ethylene dichloride, vinyl acetate monomer
acid and similar applications, where a high performance oxygen measurement is required.

SPECIFICATIONS
Gas Measured:

AMBIENT CONDITIONS
O2 Oxygen

PERFORMANCE
Technology:
Range:
Intrinsic Error
(Accuracy):
Linearity:
Repeatability:
Response Time (T90):
Zero drift/ week:
Span drift/ week:
Output Noise:

Paramagnetic Transducer
0 - 100%O2 (Minimum
recommended 0-0.5%)
<0.02% O2
<0.01% O2
0.02% O2
<4 seconds (at 250ml/min)
<0.02% O2
<0.05% O2
<0.01% O2 peak to peak within
any 5 minute period.

Effect of ambient temperature changes:


A change of 10C (18F) in the range -10 to +50C (14 to
122F) will cause the zero to change by 0.02% O2
(max) and the span to change by 0.2% of reading.
Effect of change in cell flow rate:
A change in flow rate from 50-250ml/min (0.2-1.2 l/min
for high flow) will cause the reading to change by 0.1% O2
maximum.
Effect of barometric pressure or sample vent pressure:
The analysers measure the partial pressure of O2 in the
sample gas, therefore the reading (at constant pressure or
O2 content) is proportional to the ratio of cell pressure at
the time of the analysis to that at the time of calibration
unless the pressure compensation option is fitted and
calibrated. Pressure compensation reduces the effect due
to vent pressure changes by a factor of better than 200 or
0.02% O2 whichever is the greater.
Effect of supply voltage variation:
A change of 10% in the supply voltage will cause the
output to change by less than 0.01% O2 or 0.1%
of reading whichever is the greater.
Effect of supply interruptions:
A single cycle interruption in electrical supply will have no
effect on the analyser.
Attitude Sensitivity:
Less than 0.01% O2 per degree of tilt from attitude at time
of calibration
Zero suppression:
The Zero may be suppressed in 0.01% steps to a
maximum of 99.99% suppression.

PHYSICAL
Power Supply:
100-120 or 220-240 Vac 50/60 Hz 100VA.
Sample Wetted Materials:
Borosilicate Glass, Electroless Nickel,Platinum,
Platinum/Iridium alloy, Stainless Steel (316) or Hastelloy,
Viton (Chemraz in the solvent resistant version).
Ingress Protection:
IP66, NEMA 4X
Mounting:
Wall Mounting
Weight:
15kg (33 lbs)

SIGNAL OUTPUTS/INPUTS
Transmitter Unit Analogue Output:
Single intrinsically safe 0/4-20mA. Maximum impedance
600. The output can be made to jam high or low under
fault conditions.
Transmitter Status Alarms:
Three intrinsically safe volt free single pole contacts,
allocated to NAMUR (fault, maintenance required,in
calibration/service mode).
Analogue Inputs:
Two intrinsically safe 0/4-20mA linear inputs designed for
external pressure compensation and background gas
cross-interference correction. Two intrinsically safe
NAMUR flow sensor inputs.
Digital Inputs:
Four intrinsically safe inputs, customer assignable, for
example, to manual calibration or validation of 4-20
outputs.
RS485 Connection:
Single IS twisted pair to a Servomex control unit.

Temperature:
Operating:-10C to 50C/14F to 122F
Storage: -20C to 70C/-4F to 158F
Atmospheric Pressure:
76 to 112kPaa/11 to 16.2psia
Warm Up Time:
Useable immediately, but typically 2 hours (from 20C)
Relative Humidity:
0-95% non-condensing
Altitude:
3000m

SAMPLE GAS CONDITIONS


Transmitter (Standard)
Maximum measurable oxygen concentration:
100%
Inlet Pressure:
max: 0.3kPa (0.04psig),relative to vent pressure
Sample Pressure (maximum):
28kPag (4psig) standard
Cell Flow Rate:
250ml (air)/minute or 1 l/min depending upon version
Dew Point:
5C (9F) below lowest ambient temp
Temperature:
-10C to +50C (+14F to +122F)
Particulates:
maximum 3m
Inlet connection:
1/8 NPT Female
Outlet connection:
1/8 NPT Female
Condition:
Clean, dry, free from oil and condensates.

Transmitter (High Pressure version)


Maximum measurable oxygen concentration:
21%
Inlet Pressure:
max: 0.3kPa (0.04psig),relative to vent pressure
Sample Pressure (maximum):
205kPag (30psig)
Cell Flow Rate:
250ml (air)/minute or 1 l/min depending upon version
Dew Point:
5C (9F) below lowest ambient temp
Temperature:
-10C to +50C (+14F to +122F)
Particulates:
maximum 3m
Inlet connection:
1/8 NPT Female
Outlet connection:
1/8 NPT Female
Condition:
Clean, dry,free from oil and condensates

EC Directive Compliance

Hazardous Area Approvals

The 2223 transmitter complies with the Low Voltage


Directive 73/23/EEC and the EMC Directive 89/336/EEC
(as amended by Directive 92/31/EEC), both as amended
by Directive 93/68/EEC.
It conforms to the following harmonised European
standards for product safety and electromagnetic
compatibility:

ATEX (Europe)

Ex II 2GD
EEx ia d IIC T4
(-20C < Ta <50C)
FM (USA)
Class I, II & III, Division 1
Group A,B,C,D,E,F,G
T4, Ambient temperature 50C max.
FM Zones (USA) Class I, Zone 1
AEx d ia IIC T4
Ambient temperature 50C max.
CSA (Canada)
Class I,Division 1,Groups A,B,C and D
Class II, Division 1 Groups E,F and G
Class III
Type 4X, T4, ambient temperature
50C maximum
CSA Zones
Class I, Zone 1 approval, Ex d ia (ia)
(Canada)
IIC T4 (Ta = 50C)
TIIS (Japan)
Ex ia d IIC T4X
IECEx (other)
Ex iad IIC T4 (-20C Ta +50C)
DIP A21 TA 70C

EN 61010-1: Safety requirements for electrical


equipment for measurement, control and laboratory use.
EN 61326-1: Electrical equipment for measurement,
control and laboratory use - EMC requirements (All
induced errors are less than the intrinsic error).
This product is rated for Installation Category II in
accordance with IEC 664.

Flow Schematic
This product is rated for Pollution Degree 2 in
accordance with IEC 664.

Optional
Flow
Alarm

Oxygen
Sensor

Pressure
Transducer,
Optional

Bypass Assembly, Optional


Filter,
Optional
In

Out

432

250

10

29

13

138

209

303
280

25

31

144
121

DIMENSIONS SHOWN IN MILLIMETRES

2210 and 2213 Control Units for


Servomex 2200 Oxygen Analyser

The 2210 and 2213 control units are designed to work


with the 2223 oxygen transmitter. The graphical user
interface allows for simple operation and has multilanguage capability as standard.
Controls up to six Transmitters
simultaneously
Certified for hazardous areas, flammable
dusts and flammable gases
Explosion proof design means no
instrument purge required
Simple two wire digital connection for ease
of installation
Digital Communications Enabled as
Standard
Hazardous Area Approvals:
ATEX Category 2 (2213)
ATEX Category 3 (2210)
FM Class I, Division 1 (2213)
FM Class I, Division 2 (2210)
CSA Class I, Divison 1 (2213)
CSA Class I, Division 2 (2210)
TIIS Zone 1 (2213)
IECEx Zone 1

www.servomex.com
SERVOMEX COMPANIES, AGENTS AND REPRESENTATIVES ARE LOCATED THROUGHOUT THE WORLD. YOUR NEAREST CONTACT IS:

Visit www.servomex.com for technical data sheets, application and


technology information for all Servomex analysers.
Servomex has a policy of constant product improvement and therefore
reserves the right to change specifications without notice.

Certificate No._________Q05166

BS EN ISO 9001

Servomex Group Limited, Jarvis Brook, Crowborough, East Sussex, TN6 3DU, England
Servomex B.V., Stephensonstraat 20, 2723 RN Zoetermeer, Netherlands
Servomex S.A., 8 Rue Proudhon, B.P. 50, 93212 St Denis La Plaine Cedex, France
Servomex GmbH, Mnsterstrae 5, 59065 Hamm, Germany
Servomex Company Inc., 525 Julie Rivers, Suite 185, Sugar Land, Texas 77478-2847, USA.
Servomex Asia Pacific Ltd, 7F, No.88, Sec. 6, Chung Shan N. Rd., Taipei, Taiwan
Servomex Group Limited., SAIF Zone, Executive Suites Z1-56, PO Box 8962, Sharjah, UAE.
Servomex Asia Pacific Ltd, (Spectris Instrumentation and Systems (Shanghai) Ltd)
Building 9, Shanghai Euromate Industrial Park, No.88 Lane 2888 Hua Ning Road, Xingzhuang Industrial Park, Shanghai 201108 PR China
Servomex Japan, Spectris Co.Ltd., 1F JP Kaji-cho Bldg., 3-5-2 Kandakaji-cho, Chiyoda-ku,Tokyo 101-0045, Japan

(44) 1892 652181


(31) 79-346 42 42
(33) 1 49 46 22 50
(49) 23 81 68 82 13
(1) 281-295-5800
(886) 2-2833 8848
(971) 6 557 0303

Fax (44) 1892 662253


Fax (31) 79-342 08 19
Fax (33) 1 49 46 22 51
Fax (49) 23 81 68 81 75
Fax (1) 281-295-5899
Fax (886) 2-2833 8844
Fax (971) 6 557 1242

(86) 21 6442 6488


(81) 3 3255 8162

Fax (86) 21 6442 6498


Fax (81) 3 3255 8154

Global email: info@servomex.com


Servomex Group Limited. 2005. A Spectris company. All rights reserved.

TDS2223 Rev. 7 05/05 E

Вам также может понравиться