Rev.Date
Rev.
2010-12-22
Document ID
NGP\00703
Prepared by
Approved by
Ida Marie Be
HW and SW Compatibility
Evolution Series
Table of Contents
1.
SCOPE..............................................................................................................................................2
2.
2.1
2.1.1
SW PLATFORMS .............................................................................................................................2
SW platform compatibility .................................................................................................................2
ODU SW Compatibility......................................................................................................................3
3.
4.
4.1
4.2
4.3
4.4
5.
6.
SUPERVISORY UNIT.......................................................................................................................9
7.
8.
8.1
8.2
8.3
CONNECTION PANELS.................................................................................................................11
2-IFU connection panel ...................................................................................................................11
4-IFU connection panel ...................................................................................................................11
4-IFU and DXC Frame connection panel........................................................................................11
Nera Networks
Page 1(11)
Technical Note
Rev.Date
Rev.
2010-12-22
B
HW and SW Compatibility
Document ID
NGP\00703
1. SCOPE
This document is intended for technical personnel working with the Evolution Series products. The document includes
information about compatibility between HW and SW for Evolution Series product variants and system
modes/configurations.
2. SW PLATFORMS
Evolution Series has different SW packages
Evolution Series variant/mode
SW package
Controller Unit
SW-EVOLUTION
SU (FKCN5551*-T) 2
SW-EVOLUTION1
SU (FKCN5551*-T)2
SW-EVO-PDH-IFU-APP1
SW-EVO-XPAND-IP
SW-EVO-MICRO
GIC (FNZ5744A-T)
SW-EVOLUTION-EDGE
IFU (FUBU6812*-T)
The detailed content for SW releases is found in the CSI or Release Note.
* : letter indicating version.
Evolution Series Edge (IFU and ODU) are not compatible with other Evolution Series Units
Release numbers are indicated by Rxxyy, where xx are main released number (1A. 2A, 2B etc) while yy indicates patch number (00, 01 etc)
See section 6
3
See section 4.2
2
Nera Networks
Page 2(11)
Technical Note
Rev.Date
Rev.
2010-12-22
B
HW and SW Compatibility
Document ID
NGP\00703
Controller/Mode
Controller SW rev
AccessIFU
SW-EVO-PDH-IFU-APP
SU (METRO/XPAND)
SU (METRO/XPAND)
SW-EVOLUTION R10A or
newer
SW-EVO-XPAND-IP
ODU SW
Status
SW-EVO-XPAND-IP
R1A or later
SW-EVO-XPAND-IP
R1A or later
SW-EVO-XPAND-IP
R1A all later
SW-EVOLUTION
R9A or later 4
SW-EVO-MICRO R1A
SW-EVOLUTION
SW-EVO-MICRO R1A
SW-EVO-XPAND-IP
OK
All ACM compatible ODUs have been delivered with R9A00 or higher from factory.
Nera Networks
Page 3(11)
Technical Note
Rev.Date
Rev.
2010-12-22
B
HW and SW Compatibility
Document ID
NGP\00703
XPAND
IP
XPAND
IP
Micro
METRO
XPAND
XPAND
Access
EDGE
R1A00
R1A00
R9A00
R9A00
R3B00
Not
supported
R2A00
R1A00
R9A00
R9A00
R3B00
Not
supported
Standard ODU
Standard Power
FU##AAA0A-*
Not
supported
Not
supported
R1A00
R3A00
R1A00
Not
supported
Standard ODU
High Power
FU##AAB0A-*
Not
supported
Not
supported
R5B00
R7A00
R3A00
Not
supported
Standard XCVR
High Power Space Diversity FL##ABB0A-*
Not
supported
NA
R6A00
R6A00
NA
Not
supported
R2A00
NA
R9A00
R9A00
NA
Not
supported
Not
supported
Not
supported
Not
supported
Not
supported
Not
supported
R1A00
ODU variant
Edge ODU
FU##ADA0A-*
Nera Networks
Page 4(11)
Technical Note
Rev.Date
Rev.
2010-12-22
B
HW and SW Compatibility
Document ID
NGP\00703
This table describes the meaning of the XCVR and ODU article code.
F
1
L
2
18
3-4
A
5
A
6
A
7
0
8
B
9 10
11
LA
11-12 13-14
Characters in code
Description
Value
Char 1 and 2
Char 3 and 4
ODU prefix
XCVR prefix
Frequency band
FU
FL
18 (Example)
Char 5
Not used
Char 6
Char 7
Power
Char 8
Rating
Char 9
Type
A: Standard
B : Space Diversity XCVR
D : Edge ODU
A: Standard
B: High
C: Low
0: Outdoor rated
2: Offshore rated
A: Standard
B: XPAND IP/ACM Compatible
Char 10
Char 11-12
Subband
Char 13-14
High/Low
LA: Low
HA: High
Nera Networks
Page 5(11)
Technical Note
Rev.Date
Rev.
2010-12-22
B
HW and SW Compatibility
Document ID
NGP\00703
4. IFU VARIANTS
4.1 Universal IFU
The universal IFU contains chassis, plug-in slots (covered with blank front panels) motherboard and FAN Unit.
The table below includes Universal IFU variants, compatibility with system mode along with required SW versions to
support it.
METRO and XPAND uses the SW package SW-EVOLUTION
XPAND IP uses the SW package SW-EVO-XPAND-IP
IFU variant
XPAND IP
METRO
XPAND
EDGE
FUBU6325A-T
Not supported
R1A*
R3A
Not supported
FUBU6325B-T
Not supported
R6A
R6A
Not supported
FUBU6325C-T
R1A
R10A
R10A
Not supported
* FUBU6325A-T used in METRO mode supports up to max 3+1 in frequency diversity configuration.
The Access IFU contains chassis, two plug-in slots for RIU (covered blank front panels), motherboard with controller
and user interfaces and FAN Unit.
The table below includes AccessIFU variants, compatibility with system mode along with required SW versions to
support it. AccessIFU uses the SW package SW-EVO-PDH-IFU-APP 5
IFU variant
Description
XPAND
METRO/XPAND IP/EDGE
FUBU6520A-T
4xE1
R1A00
Not supported
FUBU6520B-T
R1A00
Not supported
FUBU6644A-T
4xT1 + 2xFE
R1A00
Not supported
FUBU6644B-T
R1A00
Not supported
See section 2
Nera Networks
Page 6(11)
Technical Note
Rev.Date
Rev.
2010-12-22
B
HW and SW Compatibility
Document ID
NGP\00703
The table below includes Edge IFU variants, compatibility with system mode along with required SW versions to
support it.
EdgeIFU uses the SW package SW-EVOLUTION-EDGE 6
IFU variant
Description
EDGE
METRO/XPAND/XPAND IP
FUBU6812A
20xE1+4xFE
R1A00
Not supported
FUBU6812B
4xFE
R2A00
Not supported
The table below includes Micro IFU variants, compatibility with system mode along with required SW versions to
support it.
MicroIFU uses the SW package SW-EVO-MICRO 7
IFU variant
Description
XPAND IP
METRO/XPAND/EDGE
FUBU7033A
8xE1+4xGbE+SFP
R1A00
Not supported
6
7
See section 2
See section 2
Nera Networks
Page 7(11)
Technical Note
Rev.Date
Rev.
2010-12-22
B
HW and SW Compatibility
Document ID
NGP\00703
The table below includes RIU variants, compatibility with system mode along with required SW versions to support it.
METRO and XPAND (Universal IFU) uses the SW package SW-EVOLUTION
XPAND (Access IFU) uses the SW package SW-EVO-PDH-IFU-APP
XPAND IP uses the SW package SW-EVO-XPAND-IP
RIU variant
Description
XPAND IP
METRO
XPAND
(Universal
IFU)
XPAND
(Access IFU)
FDM5559A-T
Not supported
R1A00
R3A00
R1A00
FDM5559B-T
R1A00
R5A00
R5A00
R3A00
FDM5559C-T
Not supported
R6A00
R6A00
R1B00
Edge IFU and Micro IFU do not use RIU plug-in modules.
Nera Networks
Page 8(11)
Technical Note
Rev.Date
Rev.
2010-12-22
B
HW and SW Compatibility
Document ID
NGP\00703
6. SUPERVISORY UNIT
SU version D
SU version A, B and C
Supervisory
Unit
METRO
n+1
system
IFUs
METRO
DXC
Frame
Gigabit
Ethernet
Units
VLAN &
QoS
Support
FKCN5551D-T
7+1
OK
>2
OK
FKCN5551C-T
7+1
OK
>2
FKCN5551B-T
3+1
Max 2
FKCN5551A-T
1+1
Max 2
Ethernet
Mapping
XPAND,
Wayside 2Mb/s or
VC-4
VC-4
USB ports
Ethernet
Ports
MTU
[bytes]
XPAND
Ethernet
Data rate
Mb/s
First
SW version
with support
FKCN5551D-T
None
1632
150
R9A
FKCN5551C-T
2048
100
R6A
FKCN5551B-T
1536
100
R3A
FKCN5551A-T
1536
100
R1A
Supervisory
Unit
See section 2
Nera Networks
Page 9(11)
Technical Note
Rev.Date
Rev.
2010-12-22
B
HW and SW Compatibility
Document ID
NGP\00703
There are two versions of the Gigabit Ethernet Interface Unit for METRO; FNZ5695A-T and FNZ5695B-T.
The B version has an upgraded switch with improved QoS features. It supports QoS for all data rates. The A version has
a limitation of 250 Mb/s transmission capacity when QoS is used.
The table below includes compatibility with system mode along with required SW versions to support it.
Variant
Description
XPAND/XPAND IP
METRO
FNZ5695A-T
Not supported
R3A00
FNZ5695B-T
Not supported
R6B02
Nera Networks
Page 10(11)
Technical Note
Rev.Date
Rev.
2010-12-22
B
HW and SW Compatibility
Document ID
NGP\00703
8. CONNECTION PANELS
The connection panels are used when combining several Universal IFUs in multi-channel systems or nodes.
The tables below include references to the IFU versions and first SW versions supporting the use of panel. Please
consult the SW release note for actual system configuration support.
Note: UBM6408B requires IFU version C; FUBU6325C-T
UBM6407/ UBM6407B
UBM6408/ UBM6408B
UBM6409
Description
XPAND IP
METRO
XPAND
IFU version
UBM6407
Not supported
R3A00
R3A00
FUBU6325*-T
UBM6407B
R3A00
R3A00
R3A00
FUBU6325*-T
Description
XPAND IP
METRO
XPAND
IFU version
UBM6408
Not supported
R6A00
Not supported
FUBU6325*-T
UBM6408B
R3A00
R10A01
Not supported
FUBU6325C-T
XPAND
IFU version
Not supported
FUBU6325*-T
Description
XPAND IP
METRO
UBM6409
Not supported
R7A00
Nera Networks
Page 11(11)