Вы находитесь на странице: 1из 6

1|Page

Winfoil
eac_esi_config -nelist

# Gives all modules connected to the OSS

eaw module id

# To login in selected module

BSC Commands
RLCRP: CELL=ALL;

# Gives all sites connected to logged BSC

RLCRP: CELL= CELL ID, detail;

# Gives details of the selected cell

RLCFP: CELL=CELL ID;

# Gives cell configuration frequency data

RLDEP:CELL=CELL ID;

#CELL DESCRIPTION DATA

RLDEP:CELL=ALL;

# Gives Cell ID from BSC

RXTCP: MOTY=RXOTG, CELL=CELL ID; # Gives MO no. of the selected cell


RXTCP: MOTY=RXOTG;
RXAPP: MO= RXOTG No.;

#Gives site-id and TG mapping


# Gives all devices of the selected MO/cell

RADEP: DEV= Device No.

# Gives SNT number

mgcep:cell=all;

# Gives Cell ID from MSC

NTCOP: SNT= SNT No.

# Gives DIP/PCM number

DTSTP: DIP= DIP no.;

# Gives status of PCM/DIP

DTSTP: DIP= ALL;

# Gives all PCM status

DTSTP: DIP= ALL, STATE=ABL;


NTCOP: SNT=ALL;

# Gives all PCM having ABL status

# Gives all devices connected to the BSC

STDEP: DEV= RBLT-No. &&-No.; # Gives status of the Devices of selected range
RXAPP: MOTY=RXOTG;

# Gives all MO no. and its devices

RXTCP: MO=MO No.

# Gives cell id related to selected MO

RXCDP: MO=RXOTG-No.

# Gives Configuration of BTS

RXASP: MO=RXOTG-No.

# Gives site name & Alarms (local/remote sts)

RXASP: MOTY=RXOTG;

#Gives alarms of all BTS at once

RLSTC: CELL=SHI005A, STATE=ACTIVE;


RLSTP: CELL=SHI005A;
RXMSC: MO=RXOTG-No, RSITE= Site Name; # To Rename the BTS
;
Run CNA Program into OSS to get the changed name in DNPR
RXMFP:MO=RXOTRX-15-1; # Gives Product code(RUREVISION), Serial No. etc.

2|Page
RXMFP:MO=RXOCF-TG No.;
#Gives DXU No.(DXU_21:-2202,DXU_23:-2206,DXU_31:2964)
RLCPP:CELL=ALL;
#Gives BTS sectors radiating power
RLCXP:CELL=ALL;
#Gives Weather DTXT(Discontinuous Transmision) is ON or OFF

To Check ARFCN given to particular cell


RLCFP:CELL=SHI016A; # Gives ARFCNs allotted for particular cell

How many Max. No. of BTSs can connect to BSC


NTCOP:SNT=ALL; # in this search how many No. of RBLTs or RBL2s
To check the TRX usage in BSC
saaep:sae=1153;

To find the Cell info display on mobile:


RLMTP:ID=ALL,CELL=CELL-ID;
# Gives ID, CODE, GS,
RLMBP:ID=ID,CODE=CODE,GS=GS;
#Gives Cellinfo-display

To Reset the BTS:RXBLI: MO=RXOTG-NO, SUBORD, FORCE; To block


RXESE: MO=RXOTG-NO, SUBORD;
To make out of service
RXESI: MO=RXOTG-NO, SUBORD;
To make in-service
RXBLE: MO=RXOTG-NO, SUBORD;
To de-block
If ORDERED comes press ESC for any command

nsstp;

#CLOCK-REFERENCE STATE

Resetting the PCM of Particular BSC:DTQSR: DIP=ALL, ES, SES, SF;


DTQSR: DIP=ALL, ES2, SES2, SF;
DTQSR: DIP=ALL, UNACC, DEGR;
Error in PCM
DTQUP: DIP=RBLT-No.; To see the errors. If PCM is working
DTQDP: DIP=RBLT-No;
RXMSP: MO=RXOTG-No.,SUBORD; To see the status of TG & its subordinate.

To block dip
To de-block dip
To block device
To de-block device
To make device out of service
To make device in-service

DTBLI: DIP=DIP NO.;


DTBLE: DIP=DIP NO.;
BLODI: DEV=DEVICE NO.;
BLODE: DEV=DEVICE NO.;
EXDAE: DEV=DEVICE NO.
EXDAI: DEV=DEVICE NO.

3|Page

Example
RXBLI: MO=RXOTS-7-12-0&&-7;
RXESE: MO= RXOTS-7-12-0&&-7;
RXMOE: MO= RXOTS-7-12-0&&-7;
RXMOI: MO= RXOTS-7-11-0&&-7;
RXESI: MO= RXOTS-7-11-0&&-7;
RXBLE: MO= RXOTS-7-11-0&&-7;

Neighbour
RLNCP:CELL=cell;

# To print neighbour to cells

RLNRI:CELL=Serving cell,CELLR=Neighbour cell;

# Define neighbour

RLNRE:CELL= Serving cell,CELLR=Neighbour cell;

# End neighbour

MSC Commands
A. Opening of new number for signaling:
1. c7tzi;
2.

# clears the non operating area(NOP area)

if protected c7tli; then go to step 1,3,4,5,6,7

3. c7tci;

#copy from operating area to NOP area

4. c7gsp,tt=0,na=4,np=1,ns=91old series;

#Gives GTRC no.

5. c7gsp,tt=0,na=4,np=1,ns=91new series, GTRC= gtrc no.;


6. c7gcp:comp;
7. c7tai;

# compares OP and NOP area


# Copies NOP area into OP area

B. Opening of new number for voice channel:


1. anbzi;

# Clears entire Non-Operating area for B-table.

2 anbci;

# Copies the entire B-table from the operating area.

3 anbsi:b=31-98635,f=4,cc=0; # Used for changing the B-Number analysis table.


4 anbai;

# Copies NOP area into OP area

One TRU has 8 time slot.


X+Y+Z configuration means BTS has X- TRU, Y-TRU & Z-TRU in their sector A,B& C respectively.
Example: 2+2+2 configuration means 2-TRU in each sector A, B, C of a particular BTS.
Let for sector-A has X (say 2)-TRU means it has X*8 (say 2 * 8=16) times slot.
One time slot is used by BCCH
CBCH + SDCCH will take one time slot if CBCH=1 & SDCCH= 7
CBCH + SDCCH will take two time slot if CBCH=1 & SDCCH= 7+8=15
CBCH + SDCCH will take three time slot if CBCH=1 & SDCCH= 15+8=23 and so on
Remaining Time slot is used by TCH (No. of TCH)

4|Page

To change the SDCCH from 7 to 15 following command is used


RLCCC: CELL=CELL ID, SDCCH=2,CHGR=1;
Using these concepts & by rlcrp: cell=all; we can find the BTS configuration.
One traffic channel has data rate of
One PCM has data rate of 2048 kbps and has 32 time slots i.e. each time slot has 2048/32=64 kbps data
rate
One time slot of TRU carries 16 kbps data rate.
Therefore one TRU (i.e. 8 time slot) carries 8x16=128kbps data
Therefore for one TRU we need two time slot of a PCM (64x2=128kbps) for data transfer.
Say for 4+4+4 configuration, we have 12 TRU in a BTS. Therefore we need 24 time slot of a PCM. For
6+6+6 configuration, we have 18 TRU in a BTS. Therefore we need 36 time slot from two PCM, since
one PCM has not sufficient Time slot.

RXMSP:MO=RXOTS-20-0-0&&-7; TO SEE THE STATUS OF TIME SLOT


RXMSP:MO=RXOTS-20-1-0&&-7;
RXMSP:MO=RXOTRX-20-4; TO SEE THE STATUS OF TRX
RXMSP:MO=RXOTRX-20-5;
RXBLI:MO=RXOTRX-20-0,SUBORD,FORCE; To block particular TRX
RXBLE:MO=RXOTRX-20-0,SUBORD;

To de-block particular TRX

rxmsp:mo=rxotg-42,subord;
GPRS
rlgsp:cell= cell name;

# GPRSSUP should be YES

rlgrp:cell=cell name;

# Gives No. of Time slot NOPDCH reserved for GPRS

rlgse:cell= cell name;

# End the GPRS service

rlgsi:cell= cell name;

# Initiate the GPRS service

5|Page
HLR command
HGAPP:APNID=ALL;
HGSDP:MSISDN=9194..,all;
HGCAP;
agkdp:kind=all,akatype=0;
agkdp:kind=all,akatype=1;

# All access point ID


# All facilities on subscriber
# Gives HLR GT
# Gives GSM subscriber
# Gives UMTS subscriber

To Find the location of Subscriber


Login in HLR
HGSDP:MSISDN=91XXXXXXXXXX,all; # To Find MSC in which subscriber is latched by MSC
number
Login in MSC
MGCAP; # Gives the MSC number
CTRAI:MSISDN=91XXXXXXXXXX; #Gives MTV number
TEST SYSTEM;
PRINT VAR MTV MTV number : 327; # Gives Cell ID in Hexadecimal
END TEST;
MGCEP:CELL=ALL; #Gives BTS ID & CELL ID
Select the last hexadecimal word > Right click > Hex convert, Decimal value is the cell ID where
subscriber is latched.
For checking GPRS or EDGE
Rlbdp:cell=all;

Changing 3G frequency:
Get CELL-ID UARFCN # FOR CHECKING ARFCN
Lt all # for login to NODE-B
Pr antenna # Gives proxy numbers.in that, notedown which proxy is corresponds to
Equipment=1, Sector antenna=3, Antenna Branch=A
Get proxy No-1. #Gives Frequncy band high edge & Lw edge
Acc Proxy No. setfrequencyband
Y
21540
21590
Get Proxy No-2. #Gives Frequncy band high edge & Lw edge
Acc Proxy No. setfrequencyband
Y
21540
21590

6|Page
Get Proxy No-3. #Gives Frequncy band high edge & Lw edge
Acc Proxy No. setfrequencyband
Y
21540
21590
Bye
If you get any doubt, see the logfile in Winfoil folder

Migration of Distance:rlldc:cell=Cell ID with sector,maxta=Near about double of given distance;


rlluc:cell=Cell ID with sector,talim= Near about double of given distance;
Ericsson Minilink Installation
In the file MSM run setup file, it will ask password: sa_password, then Serial no. 1111.
After installation, it will ask password for control operator, pw is 1111

Find CGI(cell global identity):RLDEP :CELL =cell ;


Cell global identity

Expressed as mcc-mnc-lac-ci where:


mcc

Mobile country code


mnc
lac

Numeral 3 digits
Mobile network code
Location area code
Numeral 1 - 65535

ci

Cell identity
Numeral 0 65535