...Plug,ball,gate,orbutterflyvalvescanbeusedforclosedshutdownwithvaryingdegreesofsuccess.Asavery
broadstatement,theireffectivenessisafunctionoftheabrasiveorwearingqualitiesoftheeffluentcontrolled.Of
course,themosteffectivesafetyvalvingiseitherfullclosedoropen,protectingthesealingelementsfrombeing
compromisedbytheeffluent(exceptinthecaseofbutterflyvalveswhichhavesealingsurfacesfullyexposed
whenpartiallyorfullyopen).Allparametersoftheintendedusemustbeexaminedindetailtoprovideadefinitive
assessmentoftheintendedapplication.
MichaelKarr,ExecutiveVicePresident,COO
VulcanJ.M.Intl.,www.vulcanjm.com
Analog Valve Cant Do It
Twokeysafetyprinciplescomeintoplayhere:One,thesafetysystemmustbeindependentofthecontrolsystem
and,two,forprocesscontroltheacceptedsafestateisthedeenergizedstate.Isupposeonecouldusean
analogcontrolvalveforthefirstprinciplebutdon'tseehowitcouldbeusedforthesecondprinciple.Iwouldsay
thatacontrolvalvecannotbeusedasasafetyshutdownvalve.
...Beingintheintrinsicsafetyisolatorbusiness,Ialsomustnotethattheleadingcompaniesinourbusinessdonot
rateanalogI.S.isolatorsforSafetyIntegrityLevels.
(HeroEngineeringFunctionalSafetyManagementEngineeringServicesCertifiedasSIL3)
http://www.controlglobal.com/articles/2003/446/?start=1
1/7
6/23/2016
SafetySystems:CanWeUseControlValvesforSafetyShutdown?
...Imustaddthatthemechanismfortheshutdownmustallowforquickactionwhenthepowerisshutofftothe
valveandIdonotthinkthatacontrolvalveisdesignedforthisresponse.
MikeMcElroy,BusinessDevelopmentManager
Pepperl+Fuchs,www.am.pepperlfuchs.com
NC Solenoid Valves Suce
Generallyspeaking,twowayandthreewaynormallyclosedsolenoidvalveswithsyntheticrubbersealsare
consideredtobe"safetyshutoff"valves,andareusuallylistedwithanagencylikeULassuch.Thismeansthat
intheeventoflossofelectricalpowertothecoil,thevalvefailsintheclosedposition,whichismostdesirable.
Thesesolenoidvalvescanbeusedanywherethatitisrequiredtoshutoffgasesorliquidsintheeventofpower
loss.
MarkEmond,TechnicalServiceRepresentative
ParkerFluidControl,www.parker.com
(HowtoperformSolenoidTesting)
More Trouble Than Its Worth
Sureitcanbedone.Thereasonithasn'tmaybeduetooneormoreofthefollowing:
1.Pneumaticvalvepositionersaremuchmoreexpensivethanconventionalsolenoidoperatedvalves.
2.NottoomanysafetyPLCsonthemarketofferacertified420mAoutput(somedoforexampletheQuadlog
systemoffersaTUVcertified420mAanalogoutputmodule).
3.Controlvalvesoftenaren'tdesignedfortightshutoff,theyaretypicallydesignedforbettercontrol(hencethe
addedcost).
4.Typically,thevendorsthatmanufactureandsellcontrolvalvesandvalvepositionershavenotsoughtthe
necessaryfailureratedatatomeettheIEC61508standard.
5.Duetotheiroperationalnature,controlvalvesrequiremoremaintenancethanshutoffvalvesandhavea
higherdemandoncompressedair.
...Mostoftodayssafetyshutoffvalvesaresolenoidoperatedshutoffvalves.Thesolenoidvalvesitsontopofa
valveactuatorandrespondstoadiscrete(on/off)signalfromthesafetysystem.Thesolenoidwilleitherallow
compressedairtodrivethevalveclosedorreleaseairwhileaspringclosesthevalve.
...Anelectrical/pneumatic(I/P)positionerworksontopofacontrolvalveactuator.Thepositionerreceivesa420
mAsignalfromthesafetysystemandallowsthevalvetogotoanypositionbetweenfullopenandfullclosed.
Someofthepossiblebenefitsofusingacontrolvalveare:
1.Usingthepositioner,userscanpartiallyclosethevalvetovalidatesystemperformance.Today,userswould
havetoshutdowntheprocesstotestshutoffvalves.
2.Thepositionersintelligencewouldallowuserstoobtainvaluablediagnosticsforpreventivemaintenanceand
safetyrecords.
3.BustechnologylikeProfibus,HART,orFoundationfieldbusareoftenavailablewithtoday'spositioners,adding
additionaladvantages.
CharlesFialkowski,ProductManager,SafetySystems
SiemensEnergyandAutomation,www.sea.siemens.com
Its Your Call
AcontrolvalvecanbeusedinlieuofaseparatesafetyshutdownvalveforSISapplications.Onetechniqueisto
http://www.controlglobal.com/articles/2003/446/?start=1
2/7
6/23/2016
SafetySystems:CanWeUseControlValvesforSafetyShutdown?
installasolenoidinserieswiththevalvepositioner,downstreamofthepositioneroutput.Thesolenoidvalveis
operatedbyaSISsignalwhenaprocessincidentoccurs,anditsoutputsupersedesthatofthepositionertodrive
thevalvetotheshutdownposition.Inmanycasesthisoperatingsetupeliminatestheneedforanadditional
safetyvalve,piping,andinstallationspace.
(Safetyinstrumentedsystems(SIS)usedfornonsafetyapplications)
...WhileacontrolvalvecanbeusedforcontrolandasasafetyshutdownvalveforSISapplications,thereare
tradeoffstoconsider.Upside:
Usingthecontrolvalvewilleliminatethecostofanadditionalvalveandassociatedpiping.
TheDCSwillcheckfortheavailabilityofthemodulatingvalveandwillrecordvalvetravelasawayto
documentoperation.Thisisnotthecasewithdiscreteon/offsolenoidoperatedvalves.
Whenthecontrolvalveisequippedwithadigitalvalvecontroller(DVC),theDVCcanrecordvalvetravel,
actuatorpressure,setpoint,andotherparametersforvalvediagnosticpurposes.
Acontrolvalveusesabetterdesigned/matchedactuatorandinstrumentpackagethandoesthetypicalon/off
valve,withtheresultbeingtightercontrol.
Thentheresthedownside:
2of3
<1|2|3> Viewononepage
ShowComments
http://www.controlglobal.com/articles/2003/446/?start=1
3/7
6/23/2016
SafetySystems:CanWeUseControlValvesforSafetyShutdown?
Related Content
Safety Shutdown: How to Avoid the Cost of Separate Valves
IsItAllowabletoUsetheControlValveasaSafetyShutdownSystem?
We'veComeaLongWayin50YearsandAutomaticSafetyControlsAretheAirbagsoftheIndustry
DigitalFieldbusTechnologiesCatchUptoValveActuatorsandPositioners
IsItAllowedfromtheStandardPointofViewtoUsetheExistingLevelTransmittersto
InvensysSeekstoSimplifyApplication,EliminateRedundantEffortandProvideIntegrated
WhatAlltheHullabalooOverSafetyInstrumentsSystemsIsAbout?
Most Popular
Past7Days
01
02
03
04
Past30Days
Past6Months
AllTime
http://www.controlglobal.com/articles/2003/446/?start=1
4/7
04
05
6/23/2016
SafetySystems:CanWeUseControlValvesforSafetyShutdown?
About
ContactUs
Advertise
MediaKit
Rates&Spec
PrivacyPolicy
http://www.controlglobal.com/articles/2003/446/?start=1
5/7
6/23/2016
SafetySystems:CanWeUseControlValvesforSafetyShutdown?
Legal/T&C
Content
Voices
Blogs
OutofControlCartoons
News
WhitePapers
Multimedia
Special Reports
Events
Products
TechnologyRoundups
Elits
Magazine
Subscribe
DigitalEdition
IssueArchive
Reprints
Site Tools
KnowledgeCenter
Microsites
CompanyProfiles
SiteMap
Stay Connected
MyAccount
Newsletters
SocialMedia
RSS
ContactUs|Advertise|PrivacyPolicy|LegalDisclaimers,Terms&Conditions
Copyright20042016ControlGlobal.Allrightsreserved.
P:6304671300|1501E.WoodfieldRoad,Suite400N,Schaumburg,IL60173
ChemicalProcessing|Control|ControlDesign|FoodProcessing|PharmaceuticalManufacturing|PlantServices|Smart
Industry
http://www.controlglobal.com/articles/2003/446/?start=1
6/7
6/23/2016
SafetySystems:CanWeUseControlValvesforSafetyShutdown?
http://www.controlglobal.com/articles/2003/446/?start=1
7/7