Вы находитесь на странице: 1из 2

LINKWORLD DISTRIBUTORS

Import/Export 2 Africa

Contact Us - Sales and Support


To contact us, please use one of the following numbers

Phone (Monday to Friday from 7:30am until 4:30pm GMT +2)


+27 12 6634331/4 (support)
+27 12 6635571 (sales)
+27 12 6635515 (sales)

Fax
+27 12 6634224

Website
www.linkworld.co.za
E-mail
sales@linkworld.co.za
support@linkworld.co.za

Feedback on products or services


Any feedback is appreciated on our products and our service. svermaak@linkworld.co.za Manager of LinkWorld

Technical support on products


Feel free to consult with our personnel.

Address
32 Kersieboom Crescent
Swartkop Ext 4
Centurion
South Africa
0046
Lightning Arresters
Our coaxial lightning protection houses a Quarter Wave Stub. The 50 Ohm nominal impedance of this device makes the
connector suitable for high frequency applications where characteristic impedance must be maintained.
Electrical Materials
Impedance – 50 Ohms Body – Brass, White Bronze
Insertion Loss – 0.2 dB Max Contact Plating
Return Loss – -25 dB Max 7/16 – Silver
IMD – -153dBc Min N-Type – Gold
Max Power – 500 Watts Contacts
Nominal Breakdown Power – Less than 0.5, 3kA @ 8/20us Plug – Brass
Nominal Breakdown Voltage – Less than +-3, 3kA @ 8/20us Jack – BeCu
Frequency Ranges – 800 – 1000 MHz Insulators – PTFE
– 800 – 2000 MHz Durability
VSWR – < 1.1 (800 – 1000 MHz) 7/16 – MIL-C39012, Sec. 4.6.12
– < 1.2 (800 – 2000 MHz) 500 Cycles, 12 Cycle Min.
N-Type – DIN 47275, Part 2/10.82
EMP Sec. 2.1.0, 500 Cycles
Current Handling Capacity – 25 KA IEC 1000us Nickel is not used in Amphenol Lightning Arresters
Multiple Strikes – 10 Strikes
Residual Voltage – Less than 150 V Environmental
Temp. Range – -40°C thru 85°C
Mechanical
Connector Types – 1G @ 5Hz, 100Hz Characteristics & Benefits
Mating – No Active Components - Maintenance Free
7/16 – Interface as per IEC 169-4 DIN 47223 – Absorbs Multiple Lightning Strikes
N-Type – Interface as per MIL-STD-348 – Resistant to Strong Current Breakdown
– Compact Structure
Protection Method – All Weather Use
– Quarter Wave Protection

Termination Instruction HH Termination Instruction HH


Part Number: Description: Part Number: Description:
AFP1-1 7/16 Female – 7/16 Male; 870 – 960 MHz AFP2-1 7/16 Female – 7/16 Male; 870 - 960 MHz
AFP1-2 7/16 Male – 7/16 Male; 870 – 960 MHz AFP2-2 7/16 Male – 7/16 Male; 800 – 2000 MHz
AFP1-3 7/16 Female – 7/16 Female; 870 – 960 MHz AFP2-3 7/16 Female – 7/16 Female; 800 – 2000 MHz
AFP1-6 7/16 Female – 7/16 Male; 1700 – 1900 MHz
AFP1-7 7/16 Female – 7/16 Male; 800 – 2500 MHz

Termination Instruction HH Termination Instruction HH


Part Number: Description: Part Number: Description:
AFP5-1 N-Type Male – N-Type Female; 800 – 1000 MHz AFP3-1 N-Type Male – N-Type Female; 800 – 2000 MHz
AFP5-2 N-Type Male – N-Type Male; 800 – 1000 MHz AFP3-2 N-Type Male – N-Type Male; 800 – 2000 MHz
AFP5-3 N-Type Female – N-Type Female; 800 – 1000 MHz AFP3-3 N-Type Female – N-Type Female; 800 – 2000 MHz