Вы находитесь на странице: 1из 48

DESIGN OF TWO WAY SLAB

PANEL NO: S08


Span (Lx)=

3.835 m

Span (Ly)=
Ly/Lx =

5.33 m
1.39 < 2
Therefore, design a two-way slab
EDGE CONDITION: One long edge discontinuous ( Case 3 )
Assuming the depth of slab (D) =
115 mm
(dx)=
Effective Depth
96
mm
(dy)=
88
mm
Cover ( C )=
15 mm
Assuming dia. Of bar =
8 mm
Grade of Concrete (fck)=
20 N/mm2
Grade of steel (fy)=
500 N/mm2
LOAD ON SLAB(per meter run of slab):
Self weight=
Floor finishes=
Live load=
Total load (W)=
Factored load (Wu)=

2.875 kN/m
1 kN/m
2 kN/m
5.875 kN/m
8.8125 kN/m

BENDING MOMENTS:
From Table (26 of IS 456) BM Coefficients are as follows:

For negative moments (at top)


For positive moments (at bottom)

1.3
0.057
0.044

x
0.06239
0.046695

1.40
0.063
0.047

0.037
0.028

ULTIMATE MOMENT (Mux-)=


8.09 KN-m
ULTIMATE MOMENT (Mux+)=
6.05 KN-m
ULTIMATE MOMENT (Muy-)=
4.80 KN-m
ULTIMATE MOMENT (Muy+)=
3.63 KN-m
SHEAR FORCE (Vu)=WuLx/2= 16.897969 KN
max B.M =
8.09 KN-m
CHECK FOR DEPTH:
dreq =(max B.M)/(0.1338.fck.b)=
here b= 1m

Mux-= (
Mux+= (x+.Wu.Lx2)
Muy-= (y-.Wu.Lx2)
Muy+= (y+.Wu.Lx2)

54.97 mm
DEPTH PROVIDED IS SUFFICIENT

REINFORCEMENT IN X- DIRECTION:

WE KNOW
Mu = 0.87 fy Ast d [ 1- (Ast fy/bd fck) ]
Ast = [fck*b*d*(1-SQRT[1-((4.598*Mu)/(fck*bd2))]/[2fy]
Ast =
USING

204.54 mm2
8
mm dia

Ast,min=
bars

138.00

Spacing:
(1) S=(1000Xast)/(Ast)
(2) 3d
(3) 300 mm
ADOPTING A SPACING OF

245.62 mm
(OR)
288 mm
(OR)
300 mm
250 mm C/C

REINFORCEMENT IN X+ DIRECTION:

Ast =
USING
Spacing:
(1) S=(1000Xast)/(Ast)
(2) 3d
(3) 300 mm
ADOPTING A SPACING OF

150.86 mm2
8
mm dia

Ast,min=

138.00

Ast,min=

138.00

Ast,min=

138.00

bars

333.02 mm
(OR)
288 mm
(OR)
300 mm
280 mm C/C

REINFORCEMENT IN Y- DIRECTION:

Ast =
USING
Spacing:
(1) S=(1000Xast)/(Ast)
(2) 3d
(3) 300 mm
ADOPTING A SPACING OF

130.09 mm2
8
mm dia

bars

364.06 mm
(OR)
264 mm
(OR)
300 mm
260 mm C/C

REINFORCEMENT IN Y+ DIRECTION:

Ast =
USING
Spacing:
(1) S=(1000Xast)/(Ast)
(2) 3d
(3) 300 mm
ADOPTING A SPACING OF

97.51 mm2
8
mm dia

bars

364.06 mm
(OR)
264 mm
(OR)
300 mm
260 mm C/C

CHECK FOR SHEAR:


Tv = Vu/bd

0.1760205 N/mm2

PERCENTAGE OF STEEL (Pt)


(Pt = 100 Ast/bd)

0.213 %
0.4264 N/mm2
2.8 N/mm2

kTc= (k=1.3 for D<150mm)


Tc,max=

REFERING TABLE-19 OF IS 456-2000


REFERING TABLE-20 OF IS 456-2000

If Tv < kTc < Tc,max, SAFE IN SHEAR


SAFE IN SHEAR

CHECK FOR DEFLECTION:


(L/d) < (L/d)basic
(L/d)basic
Modification factor,

=
=

32
1.385

(L/d) = 28.843261
IF (L/d) < (L/d)basic, THEN SAFE IN DEFLECTION
SAFE IN DEFLECTION

3)

Mux-= (x-.Wu.Lx2)
Mux+= (x+.Wu.Lx2)
Muy-= (y-.Wu.Lx2)
Muy+= (y+.Wu.Lx2)

d2))]/[2fy]

mm2

mm2

mm2

mm2

TABLE-19 OF IS 456-2000

TABLE-20 OF IS 456-2000

DESIGN OF TWO WAY SLAB


PANEL NO: S09
Span (Lx)=

3.658 m

Span (Ly)=
Ly/Lx =

3.658 m
1.00 < 2
Therefore, design a two-way slab
EDGE CONDITION: One long edge discontinuous ( Case 3 )
Assuming the depth of slab (D) =
115 mm
(dx)=
Effective Depth
96
mm
(dy)=
88
mm
Cover ( C )=
15 mm
Assuming dia. Of bar =
8 mm
Grade of Concrete (fck)=
20 N/mm2
Grade of steel (fy)=
500 N/mm2
LOAD ON SLAB(per meter run of slab):
Self weight=
Floor finishes=
Live load=
Total load (W)=
Factored load (Wu)=

2.875 kN/m
1 kN/m
2 kN/m
5.875 kN/m
8.8125 kN/m

BENDING MOMENTS:
From Table (26 of IS 456) BM Coefficients are as follows:

For negative moments (at top)


For positive moments (at bottom)

1.0
0.037
0.028

0.037
0.028

0.037
0.028

ULTIMATE MOMENT (Mux-)=


4.36 KN-m
ULTIMATE MOMENT (Mux+)=
3.30 KN-m
ULTIMATE MOMENT (Muy-)=
4.36 KN-m
ULTIMATE MOMENT (Muy+)=
3.30 KN-m
SHEAR FORCE (Vu)=WuLx/2= 16.118063 KN
max B.M =
4.36 KN-m
CHECK FOR DEPTH:
dreq =(max B.M)/(0.1338.fck.b)=
here b= 1m

Mux-= (x-.Wu.Lx2)
Mux+= (x+.Wu.Lx2)
Muy-= (y-.Wu.Lx2)
Muy+= (y+.Wu.Lx2)

40.38 mm
DEPTH PROVIDED IS SUFFICIENT

REINFORCEMENT IN X- DIRECTION:

WE KNOW
Mu = 0.87 fy Ast d [ 1- (Ast fy/bd fck) ]
Ast = [fck*b*d*(1-SQRT[1-((4.598*Mu)/(fck*bd2))]/[2fy]
Ast =
USING

107.49 mm2
8
mm dia

Ast,min=
bars

138.00

Spacing:
(1) S=(1000Xast)/(Ast)
(2) 3d
(3) 300 mm
ADOPTING A SPACING OF

364.06 mm
(OR)
288 mm
(OR)
300 mm
280 mm C/C

REINFORCEMENT IN X+ DIRECTION:

Ast =
USING
Spacing:
(1) S=(1000Xast)/(Ast)
(2) 3d
(3) 300 mm
ADOPTING A SPACING OF

80.77 mm2
8
mm dia

Ast,min=

138.00

Ast,min=

138.00

Ast,min=

138.00

bars

364.06 mm
(OR)
288 mm
(OR)
300 mm
280 mm C/C

REINFORCEMENT IN Y- DIRECTION:

Ast =
USING
Spacing:
(1) S=(1000Xast)/(Ast)
(2) 3d
(3) 300 mm
ADOPTING A SPACING OF

117.94 mm2
8
mm dia

bars

364.06 mm
(OR)
264 mm
(OR)
300 mm
260 mm C/C

REINFORCEMENT IN Y+ DIRECTION:

Ast =
USING
Spacing:
(1) S=(1000Xast)/(Ast)
(2) 3d
(3) 300 mm
ADOPTING A SPACING OF

88.48 mm2
8
mm dia

bars

364.06 mm
(OR)
264 mm
(OR)
300 mm
260 mm C/C

CHECK FOR SHEAR:


Tv = Vu/bd

0.1678965 N/mm2

PERCENTAGE OF STEEL (Pt)


(Pt = 100 Ast/bd)

0.123 %
0.364 N/mm2
2.8 N/mm2

kTc=(k=1.3 for D<150mm)


Tc,max=

REFERING TABLE-19 OF IS 456-2000


REFERING TABLE-20 OF IS 456-2000

If Tv < kTc < Tc,max, SAFE IN SHEAR


SAFE IN SHEAR

CHECK FOR DEFLECTION:


(L/d) < (L/d)basic
(L/d)basic
Modification factor,

=
=

32
1.89

(L/d) = 20.160935
IF (L/d) < (L/d)basic, THEN SAFE IN DEFLECTION
SAFE IN DEFLECTION

3)

Mux-= (x-.Wu.Lx2)
Mux+= (x+.Wu.Lx2)
Muy-= (y-.Wu.Lx2)
Muy+= (y+.Wu.Lx2)

d2))]/[2fy]

mm2

mm2

mm2

mm2

TABLE-19 OF IS 456-2000

TABLE-20 OF IS 456-2000

DESIGN OF TWO WAY SLAB


PANEL NO: S10
Span (Lx)=

3.658 m

Span (Ly)=
Ly/Lx =

3.658 m
1.00 < 2
Therefore, design a two-way slab
EDGE CONDITION: Interior panel ( Case 1)
Assuming the depth of slab (D) =
115 mm
(dx)=
Effective Depth
96
mm
(dy)=
88
mm
Cover ( C )=
15 mm
Assuming dia. Of bar =
8 mm
Grade of Concrete (fck)=
20 N/mm2
Grade of steel (fy)=
500 N/mm2
LOAD ON SLAB(per meter run of slab):
Self weight=
Floor finishes=
Live load=
Total load (W)=
Factored load (Wu)=

2.875 kN/m
1 kN/m
2 kN/m
5.875 kN/m
8.8125 kN/m

BENDING MOMENTS:
From Table (26 of IS 456) BM Coefficients are as follows:

For negative moments (at top)


For positive moments (at bottom)

1.0
0.032
0.024

0.032
0.024

0.032
0.024

ULTIMATE MOMENT (Mux-)=


3.77 KN-m
ULTIMATE MOMENT (Mux+)=
2.83 KN-m
ULTIMATE MOMENT (Muy-)=
3.77 KN-m
ULTIMATE MOMENT (Muy+)=
2.83 KN-m
SHEAR FORCE (Vu)=WuLx/2= 16.118063 KN
max B.M =
3.77 KN-m
CHECK FOR DEPTH:
dreq =(max B.M)/(0.1338.fck.b)=
here b= 1m

Mux-= (x-.Wu.Lx2)
Mux+= (x+.Wu.Lx2)
Muy-= (y-.Wu.Lx2)
Muy+= (y+.Wu.Lx2)

37.55 mm
DEPTH PROVIDED IS SUFFICIENT

REINFORCEMENT IN X- DIRECTION:

WE KNOW
Mu = 0.87 fy Ast d [ 1- (Ast fy/bd fck) ]
Ast = [fck*b*d*(1-SQRT[1-((4.598*Mu)/(fck*bd2))]/[2fy]
Ast =
USING

92.60 mm2
8
mm dia

Ast,min=
bars

138.00

Spacing:
(1) S=(1000Xast)/(Ast)
(2) 3d
(3) 300 mm
ADOPTING A SPACING OF

364.06 mm
(OR)
288 mm
(OR)
300 mm
280 mm C/C

REINFORCEMENT IN X+ DIRECTION:

Ast =
USING
Spacing:
(1) S=(1000Xast)/(Ast)
(2) 3d
(3) 300 mm
ADOPTING A SPACING OF

69.01 mm2
8
mm dia

Ast,min=

138.00

Ast,min=

138.00

Ast,min=

138.00

bars

364.06 mm
(OR)
288 mm
(OR)
300 mm
280 mm C/C

REINFORCEMENT IN Y- DIRECTION:

Ast =
USING
Spacing:
(1) S=(1000Xast)/(Ast)
(2) 3d
(3) 300 mm
ADOPTING A SPACING OF

101.51 mm2
8
mm dia

bars

364.06 mm
(OR)
264 mm
(OR)
300 mm
260 mm C/C

REINFORCEMENT IN Y+ DIRECTION:

Ast =
USING
Spacing:
(1) S=(1000Xast)/(Ast)
(2) 3d
(3) 300 mm
ADOPTING A SPACING OF

75.56 mm2
8
mm dia

bars

364.06 mm
(OR)
264 mm
(OR)
300 mm
260 mm C/C

CHECK FOR SHEAR:


Tv = Vu/bd

0.1678965 N/mm2

PERCENTAGE OF STEEL (Pt)


(Pt = 100 Ast/bd)
kTc=(k=1.3 for D<150mm)
Tc,max=

0.106 %
0.364 N/mm2
2.8 N/mm2

REFERING TABLE-19 OF IS 456-2000


REFERING TABLE-20 OF IS 456-2000

If Tv < kTc < Tc,max, SAFE IN SHEAR


SAFE IN SHEAR

CHECK FOR DEFLECTION:


(L/d) < (L/d)basic
(L/d)basic

Modification factor,

32
1.89

(L/d) = 20.160935
IF (L/d) < (L/d)basic, THEN SAFE IN DEFLECTION
SAFE IN DEFLECTION

Mux-= (x-.Wu.Lx2)
Mux+= (x+.Wu.Lx2)
Muy-= (y-.Wu.Lx2)
Muy+= (y+.Wu.Lx2)

d2))]/[2fy]

mm2

mm2

mm2

mm2

TABLE-19 OF IS 456-2000

TABLE-20 OF IS 456-2000

DESIGN OF TWO WAY SLAB


PANEL NO: S11
Span (Lx)=

3.912 m

Span (Ly)=
Ly/Lx =

4.04 m
1.03 < 2
Therefore, design a two-way slab
EDGE CONDITION: One short edge discontinuous ( Case 2)
Assuming the depth of slab (D) =
115 mm
(dx)=
Effective Depth
96
mm
(dy)=
88
mm
Cover ( C )=
15 mm
Assuming dia. Of bar =
8 mm
Grade of Concrete (fck)=
20 N/mm2
Grade of steel (fy)=
500 N/mm2
LOAD ON SLAB(per meter run of slab):
Self weight=
Floor finishes=
Live load=
Total load (W)=
Factored load (Wu)=

2.875 kN/m
1 kN/m
2 kN/m
5.875 kN/m
8.8125 kN/m

BENDING MOMENTS:
From Table (26 of IS 456) BM Coefficients are as follows:

For negative moments (at top)


For positive moments (at bottom)
ULTIMATE MOMENT (Mux-)=
ULTIMATE MOMENT (Mux+)=
ULTIMATE MOMENT (Muy-)=
ULTIMATE MOMENT (Muy+)=
SHEAR FORCE (Vu)=WuLx/2=
max B.M =
CHECK FOR DEPTH:
dreq =(max B.M)/(0.1338.fck.b)=
here b= 1m

1.3
0.051
0.039

x
0.040309
0.033654

1.40
0.055
0.041

0.037
0.028
Mux-= (x-.Wu.Lx2)
Mux+= (x+.Wu.Lx2)
Muy-= (y-.Wu.Lx2)
Muy+= (y+.Wu.Lx2)

5.44 KN-m
4.54 KN-m
4.99 KN-m
3.78 KN-m
17.23725 KN
5.44 KN-m

45.07 mm
DEPTH PROVIDED IS SUFFICIENT

REINFORCEMENT IN X- DIRECTION:

WE KNOW
Mu = 0.87 fy Ast d [ 1- (Ast fy/bd fck) ]
Ast = [fck*b*d*(1-SQRT[1-((4.598*Mu)/(fck*bd2))]/[2fy]
Ast =
USING

134.93 mm2
8
mm dia

Ast,min=
bars

138.00

Spacing:
(1) S=(1000Xast)/(Ast)
(2) 3d
(3) 300 mm
ADOPTING A SPACING OF

364.06 mm
(OR)
288 mm
(OR)
300 mm
280 mm C/C

REINFORCEMENT IN X+ DIRECTION:

Ast =
USING
Spacing:
(1) S=(1000Xast)/(Ast)
(2) 3d
(3) 300 mm
ADOPTING A SPACING OF

111.96 mm2
8
mm dia

Ast,min=

138.00

Ast,min=

138.00

Ast,min=

138.00

bars

364.06 mm
(OR)
288 mm
(OR)
300 mm
280 mm C/C

REINFORCEMENT IN Y- DIRECTION:

Ast =
USING
Spacing:
(1) S=(1000Xast)/(Ast)
(2) 3d
(3) 300 mm
ADOPTING A SPACING OF

135.59 mm2
8
mm dia

bars

364.06 mm
(OR)
264 mm
(OR)
300 mm
260 mm C/C

REINFORCEMENT IN Y+ DIRECTION:

Ast =
USING
Spacing:
(1) S=(1000Xast)/(Ast)
(2) 3d
(3) 300 mm
ADOPTING A SPACING OF

101.58 mm2
8
mm dia

bars

364.06 mm
(OR)
264 mm
(OR)
300 mm
260 mm C/C

CHECK FOR SHEAR:


Tv = Vu/bd

0.1795547 N/mm2

PERCENTAGE OF STEEL (Pt)


(Pt = 100 Ast/bd)
kTc=(k=1.3 for D<150mm)
Tc,max=

0.141 %
0.364 N/mm2
2.8 N/mm2

REFERING TABLE-19 OF IS 456-2000


REFERING TABLE-20 OF IS 456-2000

If Tv < kTc < Tc,max, SAFE IN SHEAR


SAFE IN SHEAR

CHECK FOR DEFLECTION:


(L/d) < (L/d)basic
(L/d)basic

Modification factor,

32
1.68

(L/d) = 24.255952
IF (L/d) < (L/d)basic, THEN SAFE IN DEFLECTION
SAFE IN DEFLECTION

2)

Mux-= (x-.Wu.Lx2)
Mux+= (x+.Wu.Lx2)
Muy-= (y-.Wu.Lx2)
Muy+= (y+.Wu.Lx2)

d2))]/[2fy]

mm2

mm2

mm2

mm2

TABLE-19 OF IS 456-2000

TABLE-20 OF IS 456-2000

DESIGN OF TWO WAY SLAB


PANEL NO: S12
Span (Lx)=

3.835 m

Span (Ly)=
Ly/Lx =

5.33 m
1.39 < 2
Therefore, design a two-way slab
EDGE CONDITION: Interior panel ( Case 1)
Assuming the depth of slab (D) =
115 mm
(dx)=
Effective Depth
96
mm
(dy)=
88
mm
Cover ( C )=
15 mm
Assuming dia. Of bar =
8 mm
Grade of Concrete (fck)=
20 N/mm2
Grade of steel (fy)=
500 N/mm2
LOAD ON SLAB(per meter run of slab):
Self weight=
Floor finishes=
Live load=
Total load (W)=
Factored load (Wu)=

2.875 kN/m
1 kN/m
2 kN/m
5.875 kN/m
8.8125 kN/m

BENDING MOMENTS:
From Table (26 of IS 456) BM Coefficients are as follows:

For negative moments (at top)


For positive moments (at bottom)

1.3
0.047
0.036

x
0.050593
0.038695

1.40
0.051
0.039

0.032
0.024

ULTIMATE MOMENT (Mux-)=


6.56 KN-m
ULTIMATE MOMENT (Mux+)=
5.02 KN-m
ULTIMATE MOMENT (Muy-)=
4.15 KN-m
ULTIMATE MOMENT (Muy+)=
3.11 KN-m
SHEAR FORCE (Vu)=WuLx/2= 16.897969 KN
max B.M =
6.56 KN-m
CHECK FOR DEPTH:
dreq =(max B.M)/(0.1338.fck.b)=
here b= 1m

Mux-= (x-.Wu.Lx2)
Mux+= (x+.Wu.Lx2)
Muy-= (y-.Wu.Lx2)
Muy+= (y+.Wu.Lx2)

49.50 mm
DEPTH PROVIDED IS SUFFICIENT

REINFORCEMENT IN X- DIRECTION:

WE KNOW
Mu = 0.87 fy Ast d [ 1- (Ast fy/bd fck) ]
Ast = [fck*b*d*(1-SQRT[1-((4.598*Mu)/(fck*bd2))]/[2fy]
Ast =
USING

164.04 mm2
8
mm dia

Ast,min=
bars

138.00

Spacing:
(1) S=(1000Xast)/(Ast)
(2) 3d
(3) 300 mm
ADOPTING A SPACING OF

306.27 mm
(OR)
288 mm
(OR)
300 mm
280 mm C/C

REINFORCEMENT IN X+ DIRECTION:

Ast =
USING
Spacing:
(1) S=(1000Xast)/(Ast)
(2) 3d
(3) 300 mm
ADOPTING A SPACING OF

124.11 mm2
8
mm dia

Ast,min=

138.00

Ast,min=

138.00

Ast,min=

138.00

bars

364.06 mm
(OR)
288 mm
(OR)
300 mm
280 mm C/C

REINFORCEMENT IN Y- DIRECTION:

Ast =
USING
Spacing:
(1) S=(1000Xast)/(Ast)
(2) 3d
(3) 300 mm
ADOPTING A SPACING OF

111.91 mm2
8
mm dia

bars

364.06 mm
(OR)
264 mm
(OR)
300 mm
260 mm C/C

REINFORCEMENT IN Y+ DIRECTION:

Ast =
USING
Spacing:
(1) S=(1000Xast)/(Ast)
(2) 3d
(3) 300 mm
ADOPTING A SPACING OF

83.23 mm2
8
mm dia

bars

364.06 mm
(OR)
264 mm
(OR)
300 mm
260 mm C/C

CHECK FOR SHEAR:


Tv = Vu/bd

0.1760205 N/mm2

PERCENTAGE OF STEEL (Pt)


(Pt = 100 Ast/bd)
kTc=(k=1.3 for D<150mm)
Tc,max=

0.171 %
0.364 N/mm2
2.8 N/mm2

REFERING TABLE-19 OF IS 456-2000


REFERING TABLE-20 OF IS 456-2000

If Tv < kTc < Tc,max, SAFE IN SHEAR


SAFE IN SHEAR

CHECK FOR DEFLECTION:


(L/d) < (L/d)basic
(L/d)basic

Modification factor,

32
1.68

(L/d) = 23.778522
IF (L/d) < (L/d)basic, THEN SAFE IN DEFLECTION
SAFE IN DEFLECTION

Mux-= (x-.Wu.Lx2)
Mux+= (x+.Wu.Lx2)
Muy-= (y-.Wu.Lx2)
Muy+= (y+.Wu.Lx2)

d2))]/[2fy]

mm2

mm2

mm2

mm2

TABLE-19 OF IS 456-2000

TABLE-20 OF IS 456-2000

DESIGN OF TWO WAY SLAB


PANEL NO: S15
Span (Lx)=

2.134 m

Span (Ly)=
Ly/Lx =

3.658 m
1.71 < 2
Therefore, design a two-way slab
EDGE CONDITION: Two adjacent edges discontinuous ( Case 4)
Assuming the depth of slab (D) =
115 mm
(dx)=
Effective Depth
96
mm
(dy)=
88
mm
Cover ( C )=
15 mm
Assuming dia. Of bar =
8 mm
Grade of Concrete (fck)=
20 N/mm2
Grade of steel (fy)=
500 N/mm2
LOAD ON SLAB(per meter run of slab):
Self weight=
Floor finishes=
Live load=
Total load (W)=
Factored load (Wu)=

2.875 kN/m
1 kN/m
2 kN/m
5.875 kN/m
8.8125 kN/m

BENDING MOMENTS:
From Table (26 of IS 456) BM Coefficients are as follows:

For negative moments (at top)


For positive moments (at bottom)

1.5
0.075
0.056

x
0.082709
0.061996

1.75
0.084
0.063

0.047
0.035

ULTIMATE MOMENT (Mux-)=


3.32 KN-m
ULTIMATE MOMENT (Mux+)=
2.49 KN-m
ULTIMATE MOMENT (Muy-)=
1.89 KN-m
ULTIMATE MOMENT (Muy+)=
1.40 KN-m
SHEAR FORCE (Vu)=WuLx/2= 9.4029375 KN
max B.M =
3.32 KN-m
CHECK FOR DEPTH:
dreq =(max B.M)/(0.1338.fck.b)=
here b= 1m

Mux-= (x-.Wu.Lx2)
Mux+= (x+.Wu.Lx2)
Muy-= (y-.Wu.Lx2)
Muy+= (y+.Wu.Lx2)

35.22 mm
DEPTH PROVIDED IS SUFFICIENT

REINFORCEMENT IN X- DIRECTION:

WE KNOW
Mu = 0.87 fy Ast d [ 1- (Ast fy/bd fck) ]
Ast = [fck*b*d*(1-SQRT[1-((4.598*Mu)/(fck*bd2))]/[2fy]
Ast =
USING

81.21 mm2
8
mm dia

Ast,min=
bars

138.00

Spacing:
(1) S=(1000Xast)/(Ast)
(2) 3d
(3) 300 mm
ADOPTING A SPACING OF

364.06 mm
(OR)
288 mm
(OR)
300 mm
280 mm C/C

REINFORCEMENT IN X+ DIRECTION:

Ast =
USING
Spacing:
(1) S=(1000Xast)/(Ast)
(2) 3d
(3) 300 mm
ADOPTING A SPACING OF

60.54 mm2
8
mm dia

Ast,min=

138.00

Ast,min=

138.00

Ast,min=

138.00

bars

364.06 mm
(OR)
288 mm
(OR)
300 mm
280 mm C/C

REINFORCEMENT IN Y- DIRECTION:

Ast =
USING
Spacing:
(1) S=(1000Xast)/(Ast)
(2) 3d
(3) 300 mm
ADOPTING A SPACING OF

49.99 mm2
8
mm dia

bars

364.06 mm
(OR)
264 mm
(OR)
300 mm
260 mm C/C

REINFORCEMENT IN Y+ DIRECTION:

Ast =
USING
Spacing:
(1) S=(1000Xast)/(Ast)
(2) 3d
(3) 300 mm
ADOPTING A SPACING OF

37.09 mm2
8
mm dia

bars

364.06 mm
(OR)
264 mm
(OR)
300 mm
260 mm C/C

CHECK FOR SHEAR:


Tv = Vu/bd

0.0979473 N/mm2

PERCENTAGE OF STEEL (Pt)


(Pt = 100 Ast/bd)
kTc=(k=1.3 for D<150mm)
Tc,max=

0.085 %
0.364 N/mm2
2.8 N/mm2

REFERING TABLE-19 OF IS 456-2000


REFERING TABLE-20 OF IS 456-2000

If Tv < kTc < Tc,max, SAFE IN SHEAR


SAFE IN SHEAR

CHECK FOR DEFLECTION:


(L/d) < (L/d)basic
(L/d)basic
Modification factor,

=
=

32
1.95

(L/d) = 11.399573
IF (L/d) < (L/d)basic, THEN SAFE IN DEFLECTION
SAFE IN DEFLECTION

ase 4)

Mux-= (x-.Wu.Lx2)
Mux+= (x+.Wu.Lx2)
Muy-= (y-.Wu.Lx2)
Muy+= (y+.Wu.Lx2)

d2))]/[2fy]

mm2

mm2

mm2

mm2

TABLE-19 OF IS 456-2000

TABLE-20 OF IS 456-2000

DESIGN OF TWO WAY SLAB


PANEL NO: S17
Span (Lx)=

3.658 m

Span (Ly)=
Ly/Lx =

3.658 m
1.00 < 2
Therefore, design a two-way slab
EDGE CONDITION: Two adjacent sides discontinuous ( Case 4)
Assuming the depth of slab (D) =
115 mm
(dx)=
Effective Depth
96
mm
(dy)=
88
mm
Cover ( C )=
15 mm
Assuming dia. Of bar =
8 mm
Grade of Concrete (fck)=
20 N/mm2
Grade of steel (fy)=
500 N/mm2
LOAD ON SLAB(per meter run of slab):
Self weight=
Floor finishes=
Live load=
Total load (W)=
Factored load (Wu)=

2.875 kN/m
1 kN/m
2 kN/m
5.875 kN/m
8.8125 kN/m

BENDING MOMENTS:
From Table (26 of IS 456) BM Coefficients are as follows:

For negative moments (at top)


For positive moments (at bottom)

1.0
0.047
0.035

0.047
0.035

0.047
0.035

ULTIMATE MOMENT (Mux-)=


5.54 KN-m
ULTIMATE MOMENT (Mux+)=
4.13 KN-m
ULTIMATE MOMENT (Muy-)=
5.54 KN-m
ULTIMATE MOMENT (Muy+)=
4.13 KN-m
SHEAR FORCE (Vu)=WuLx/2= 16.118063 KN
max B.M =
5.54 KN-m
CHECK FOR DEPTH:
dreq =(max B.M)/(0.1338.fck.b)=
here b= 1m

Mux-= (x-.Wu.Lx2)
Mux+= (x+.Wu.Lx2)
Muy-= (y-.Wu.Lx2)
Muy+= (y+.Wu.Lx2)

45.51 mm
DEPTH PROVIDED IS SUFFICIENT

REINFORCEMENT IN X- DIRECTION:

WE KNOW
Mu = 0.87 fy Ast d [ 1- (Ast fy/bd fck) ]
Ast = [fck*b*d*(1-SQRT[1-((4.598*Mu)/(fck*bd2))]/[2fy]
Ast =
USING

137.66 mm2
8
mm dia

Ast,min=
bars

138.00

Spacing:
(1) S=(1000Xast)/(Ast)
(2) 3d
(3) 300 mm
ADOPTING A SAPACING OF

364.06 mm
(OR)
288 mm
(OR)
300 mm
280 mm C/C

REINFORCEMENT IN X+ DIRECTION:

Ast =
USING
Spacing:
(1) S=(1000Xast)/(Ast)
(2) 3d
(3) 300 mm
ADOPTING A SPACING OF

101.52 mm2
8
mm dia

Ast,min=

138.00

Ast,min=

138.00

Ast,min=

138.00

bars

364.06 mm
(OR)
288 mm
(OR)
300 mm
280 mm C/C

REINFORCEMENT IN Y- DIRECTION:

Ast =
USING
Spacing:
(1) S=(1000Xast)/(Ast)
(2) 3d
(3) 300 mm
ADOPTING A SPACING OF

151.29 mm2
8
mm dia

bars

332.07 mm
(OR)
264 mm
(OR)
300 mm
260 mm C/C

REINFORCEMENT IN Y+ DIRECTION:

Ast =
USING
Spacing:
(1) S=(1000Xast)/(Ast)
(2) 3d
(3) 300 mm
ADOPTING A SPACING OF

111.34 mm2
8
mm dia

bars

364.06 mm
(OR)
264 mm
(OR)
300 mm
260 mm C/C

CHECK FOR SHEAR:


Tv = Vu/bd

0.1678965 N/mm2

PERCENTAGE OF STEEL (Pt)


(Pt = 100 Ast/bd)
kTc=(k=1.3 for D<150mm)
Tc,max=

0.158 %
0.364 N/mm2
2.8 N/mm2

REFERING TABLE-19 OF IS 456-2000


REFERING TABLE-20 OF IS 456-2000

If Tv < kTc < Tc,max, SAFE IN SHEAR


SAFE IN SHEAR

CHECK FOR DEFLECTION:


(L/d) < (L/d)basic
(L/d)basic
Modification factor,

=
=

32
1.68

22.681052
IF (L/d) < (L/d)basic, THEN SAFE IN DEFLECTION
SAFE IN DEFLECTION

ase 4)

Mux-= (x-.Wu.Lx2)
Mux+= (x+.Wu.Lx2)
Muy-= (y-.Wu.Lx2)
Muy+= (y+.Wu.Lx2)

d2))]/[2fy]

mm2

mm2

mm2

mm2

TABLE-19 OF IS 456-2000

TABLE-20 OF IS 456-2000

DESIGN OF TWO WAY SLAB


PANEL NO: S17
Span (Lx)=

1.22 m

Span (Ly)=
Ly/Lx =

1.98 m
1.62 < 2
Therefore, design a two-way slab
EDGE CONDITION: One short edge discontinuous ( Case 2)
Assuming the depth of slab (D) =
115 mm
(dx)=
Effective Depth
96
mm
(dy)=
88
mm
Cover ( C )=
15 mm
Assuming dia. Of bar =
8 mm
Grade of Concrete (fck)=
20 N/mm2
Grade of steel (fy)=
500 N/mm2
LOAD ON SLAB(per meter run of slab):
Self weight=
Floor finishes=
Live load=
Total load (W)=
Factored load (Wu)=

2.875 kN/m
1 kN/m
2 kN/m
5.875 kN/m
8.8125 kN/m

BENDING MOMENTS:
From Table (26 of IS 456) BM Coefficients are as follows:

For negative moments (at top)


For positive moments (at bottom)
ULTIMATE MOMENT (Mux-)=
ULTIMATE MOMENT (Mux+)=
ULTIMATE MOMENT (Muy-)=
ULTIMATE MOMENT (Muy+)=
SHEAR FORCE (Vu)=WuLx/2=
max B.M =
CHECK FOR DEPTH:
dreq =(max B.M)/(0.1338.fck.b)=
here b= 1m

1.5
0.057
0.044

x
0.060443
0.045967

1.75
0.064
0.048

0.037
0.028
Mux-= (x-.Wu.Lx2)
Mux+= (x+.Wu.Lx2)
Muy-= (y-.Wu.Lx2)
Muy+= (y+.Wu.Lx2)

0.79 KN-m
0.60 KN-m
0.49 KN-m
0.37 KN-m
5.375625 KN
0.79 KN-m

17.21 mm
DEPTH PROVIDED IS SUFFICIENT

REINFORCEMENT IN X- DIRECTION:

WE KNOW
Mu = 0.87 fy Ast d [ 1- (Ast fy/bd fck) ]
Ast = [fck*b*d*(1-SQRT[1-((4.598*Mu)/(fck*bd2))]/[2fy]
Ast =
USING

19.08 mm2
8
mm dia

Ast,min=
bars

138.00

Spacing:
(1) S=(1000Xast)/(Ast)
(2) 3d
(3) 300 mm
ADOPTING A SAPACING OF

364.06 mm
(OR)
288 mm
(OR)
300 mm
280 mm C/C

REINFORCEMENT IN X+ DIRECTION:

Ast =
USING
Spacing:
(1) S=(1000Xast)/(Ast)
(2) 3d
(3) 300 mm
ADOPTING A SPACING OF

14.49 mm2
8
mm dia

Ast,min=

138.00

Ast,min=

138.00

Ast,min=

138.00

bars

364.06 mm
(OR)
288 mm
(OR)
300 mm
280 mm C/C

REINFORCEMENT IN Y- DIRECTION:

Ast =
USING
Spacing:
(1) S=(1000Xast)/(Ast)
(2) 3d
(3) 300 mm
ADOPTING A SPACING OF

12.72 mm2
8
mm dia

bars

364.06 mm
(OR)
264 mm
(OR)
300 mm
260 mm C/C

REINFORCEMENT IN Y+ DIRECTION:

Ast =
USING
Spacing:
(1) S=(1000Xast)/(Ast)
(2) 3d
(3) 300 mm
ADOPTING A SPACING OF

9.62 mm2
8
mm dia

bars

364.06 mm
(OR)
264 mm
(OR)
300 mm
260 mm C/C

CHECK FOR SHEAR:


Tv = Vu/bd

0.0559961 N/mm2

PERCENTAGE OF STEEL (Pt)


(Pt = 100 Ast/bd)
kTc=(k=1.3 for D<150mm)
Tc,max=

0.020 %
0.364 N/mm2
2.8 N/mm2

REFERING TABLE-19 OF IS 456-2000


REFERING TABLE-20 OF IS 456-2000

If Tv < kTc < Tc,max, SAFE IN SHEAR


SAFE IN SHEAR

CHECK FOR DEFLECTION:


(L/d) < (L/d)basic
(L/d)basic
Modification factor,

=
=

32
1.68

7.5644841
IF (L/d) < (L/d)basic, THEN SAFE IN DEFLECTION
SAFE IN DEFLECTION

2)

Mux-= (x-.Wu.Lx2)
Mux+= (x+.Wu.Lx2)
Muy-= (y-.Wu.Lx2)
Muy+= (y+.Wu.Lx2)

d2))]/[2fy]

mm2

mm2

mm2

mm2

TABLE-19 OF IS 456-2000

TABLE-20 OF IS 456-2000

Вам также может понравиться