MODELS:
CH-S09FTXG
CH-S12FTXG
CH-S18FTXG
CH-S24FTXG
For proper operation, please read and keep this manual carefully.
Designed by Cooper&Hunter International Corporation, Oregon, USA
www.cooperandhunter.com
Energy Label
Annual energy efficiency perfomance ratio is
Device Energy Lable
calculated by overall capacity and average
operaing time (apr 500 hours) multiplication in
full-load coling mode operation.
Air Conditioner
Manufacturer
Outdoor unit
Indoor unit
Cooling capacity
is device cooling capaciy (demanded in kWh) in Cooling mode Energy Label Class
full-load cooling mode operation. ERR energy
Maximum efficiency
label index is ratio of cooling capacity to its
electric energy input attainment. Energy label
depends on ERR index rate.
Minimum efficiency
A
B
C
D
E
F
G
3.6 COP
3.4 COP < 3.6
3.2 COP < 3.4
2.8 COP < 3.2
2.6 COP < 2.8
2.4 COP < 2.6
COP < 2.4
Operation Notices
Content
Precautions............................................................................................................1
Parts name ............................................................................................................6
Maintenance
Malfunction
Installation Notice
Installation
Attachment
Precautions
WARNING
Operation and Maintenance
This appliance can be used by children aged from 8
years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe
way and understand the hazards involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by
children without supervision.
Do not connect air conditioner to multi-purpose socket.
Otherwise, it may cause fire hazard.
Do disconnect power supply when cleaning air
conditioner. Otherwise, it may cause electric shock.
.
If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
Do not wash the air conditioner with water to avoid
electric shock.
Do not spray water on indoor unit. It may cause electric
shock or malfunction.
After removing the filter, do not touch fins to avoid injury.
Do not use fire or hair dryer to dry the filter to avoid
deformation or fire hazard.
1
Precautions
WARNING
Maintenance must be performed by qualified
professionals. Otherwise, it may cause personal injury
or damage.
Do not repair air conditioner by yourself. It may cause
electric shock or damage. Please contact dealer when
you need to repair air conditioner.
Do not extend fingers or objects into air inlet or air
outlet. It may cause personal injury or damage.
Do not block air outlet or air inlet. It may cause
malfunction.
Do not spill water on the remote controller, otherwise the
remote controller may be broken.
When below phenomenon occurs, please turn off air
conditioner and disconnect power immediately, and then
contact the dealer or qualified professionals for service.
Power cord is overheating or damaged.
Theres abnormal sound during operation.
Circuit break trips off frequently.
Air conditioner gives off burning smell.
Indoor unit is leaking.
If the air conditioner operates under abnormal conditions,
it may cause malfunction, electric shock or fire hazard.
When turning on or turning off the unit by emergency
operation switch, please press this switch with an insulating
object other than metal.
Do not step on top panel of outdoor unit, or put heavy
objects. It may cause damage or personal injury.
2
Precautions
WARNING
Attachment
Installation must be performed by qualified professionals.
Otherwise, it may cause personal injury or damage.
Must follow the electric safety regulations when installing
the unit.
According to the local safety regulations, use qualified
power supply circuit and circuit break.
Do install the circuit break. If not, it may cause malfunction.
An all-pole disconnection switch having a contact separation
of at least 3mm in all poles should be connected in fixed
wiring.
Including an circuit break with suitable capacity, please
note the following table.Air switch should be included
magnet buckle and heating buckle function, it can protect
the circuit-short and overload.
Air Conditioner should be properly grounded. Incorrect
grounding may cause electric shock.
Don't use unqualified power cord.
Make sure the power supply matches with the
requirement of air conditioner.Unstable power supply or
incorrect wiring or malfunction. Please install proper power
supply cables before using the air conditioner.
Properly connect the live wire, neutral wire and
grounding wire of power socket.
Be sure to cut off the power supply before proceeding
any work related to electricity and safety.
3
Precautions
WARNING
Do not put through the power before finishing installation.
If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
The temperature of refrigerant circuit will be high, please
keep the interconnection cable away from the copper
tube.
The appliance shall be installed in accordance with
national wiring regulations.
Installation must be performed in accordance with the
requirement of NEC and CEC by authorized personnel
only.
The air conditioner is the first class electric appliance. It
must be properly grounding with specialized grounding
device by a professional. Please make sure it is always
grounded effectively, otherwise it may cause electric shock.
The yellow-green wire in air conditioner is grounding
wire, which can't be used for other purposes.
The grounding resistance should comply with national
electric safety regulations.
The appliance must be positioned so that the plug is
accessible.
All wires of indoor unit and outdoor unit should be
connected by a professional.
If the length of power connection wire is insufficient, please
contact the supplier for a new one. Avoid extending the
wire by yourself.
4
Precautions
WARNING
For the air conditioner with plug, the plug should be
reachable after finishing installation.
For the air conditioner without plug, an circuit break
must be installed in the line.
If you need to relocate the air conditioner to another
place, only the qualified person can perform the work.
Otherwise, it may cause personal injury or damage.
Select a location which is out of reach for children and
far away from animals or plants.If it is unavoidable,
please add the fence for safety purpose.
The indoor unit should be installed close to the wall.
Working temperature range
Maximum cooling
Maximum heating
NOTICE:
The operating temperature range (outdoor temperature) for cooling only unit is
18 ~43 ; for heat pump unit is -15 ~ 43 .
Parts Name
Indoor Unit
panel
air inlet
air outlet
horizontal louver
display
temp. indicator
cooling indicator
drying indicator
heating indicator
power indicator
FAN AUTO
OPER
AIR HEALTH X-FAN
HUMIDITY
FILTER
TURBO
HOUR
ON/OFF
ON/OFF
aux.button
receiver window
FAN
Outdoor Unit
MODE
X-FAN
TEMP
TIMER
TURBO
SLEEP
LIGHT
remote control
air inlet
handle
air outlet
NOTICE:
Actual product may be different from above graphics, please refer to actual
products.
AUTO
OPER
FILTER
TURBO
HOUR
ON/OFF
1
3
ON/OFF
MODE
FAN
8
9
11
X-FAN
TEMP
TIMER
TURBO
SLEEP
LIGHT
ON/OFF button
MODE button
+/- button
FAN button
button
button
X-FAN button
TEMP button
10
10 TIMER button
11 TURBO button
13
12 SLEEP button
12
13 LIGHT button
AUTO
FILTER
send signal
health mode
X-fan
set temperature
TURBO
HOUR
ON/OFF
Child Lock
Sleep mode
Temp. display type
:Set temp.
:Indoor ambient temp.
:Outdoor ambient temp.
OPER
turbo mode
TIMER ON/TIMER OFF
set time
left & right swing
light
After putting through power, air conditioner will give out a sound and operation
indicator " " is ON (red indicator). You can operate the air conditioner through
the remote controller.
At ON status, after each pressing button on remote controller, the signal icon " "
indicates the signal has been sent to air conditioner.
At OFF status, display screen on remote controller displays set temperature.
At on status, display screen on remote controller displays the corresponding startup
functions icon.
ON/OFF button
Press this button can turn on or turn off the air conditioner. After turning on the unit,
operation indicator " " on indoor unit is ON (green indicator. Color may be different for different models)and indoor unit gives out a sound.
MODE button
COOL
DRY
FAN
HEAT
After selecting auto mode, air conditioner will operate automatically according to
ambient temperature. Set temperature cant be adjusted and also cant be displayed. Press "FAN" button can adjust fan speed. Press " " button can adjust swing
angle.
After selecting cool mode, air conditioner operates under cool mode. Cool indicator
" " on indoor unit is ON. You can press "+" or "-" button to adjust set temperature.
Press "FAN" button can adjust fan speed. Press " " button can adjust swing
angle.
After selecting dry mode, air conditioner operates under dry mode at low speed.
Dry indicator " " on indoor unit is ON. Under dry mode, fan speed cant be adjusted. Press " " button to adjust swing angle.
After selecting fan mode, air conditioner operates only under fan mode, All mode
indicators on indoor unit is OFF. Operation indicator is ON. Press "FAN" button can
adjust fan speed. Press " " button to adjust swing angle.
After selecting heat mode, air conditioner operates under heat mode. Heat indicator
" " on indoor unit is ON. You can press "+" or "-" button to adjust set temperature.
Press "FAN" button to adjust fan speed. Press " " button to adjust swing angle.
(Cooling only unit cant receive the signal for heating mode.)
For preventing cold wind, after starting up heating mode, indoor fan will blow fan
afterdelaying 1-5min. (Details time is decided by indoor ambient temperature)
Temperature setting range on remote controller: 16 -30 . Fan speed setting
range: auto, low speed, medium speed and high speed.
After each pressing of "+" or "-" button, it can increase or decrease set temperature 1 . Hold "+" or "-" button, 2s later, set temperature on remote controller
will change quickly. After reaching to your required time, loosen the button.
Temperature indicator on indoor unit will also change accordingly. (Temperature
cant be adjusted under auto mode)
Under TIMER ON, TIMER OFF or Clock setting, you can press "+"or "-" button to
adjust time. (Refer to TIMER button for details)
FAN button
Pressing this button can set fan speed circularly as: auto (AUTO), low(
medium(
), high(
).
),
Auto
Note:
Under AUTO Speed,IDU fan motor will adjust the fan speed (high, medium or
low speed) according to ambient temperature.
Fan speed under dry mode is low speed.
button
Press this button to start or stop up & down swing function.The remote controller
defaults to simple swing condition.
Press + button and
button at the same time at unit OFF to switch between
simple swing and static swing;
blinks for 2 seconds.
In static swing condition, pressing button, the swing angle of up & down louver
changes as below:
no display
(horizontal louvers stops
at current position)
If the unit is turned off during swing operation,the louver will stop at present
position.
When selecting " " with remote controller, its auto swing. Horizontal louver of air
conditioner will swing up&down automatically at the maximum angle.
When selecting "
swing. Horizontal louver of air conditioner will stop at that position as shown by the
icon to swing.
button
Press this button to start or stop left & right swing function. The remote controller
defaults to simple swing condition.
Press + button and
button at the same time at unit OFF to switch between
simple swing and static swing;
blinks for 2 seconds.
In static swing condition, pressing button, the swing angle of left & right louver
changes as below:
no display
(horizontal louvers stops
at current position)
If the unit is turned off during swing operation,the louver will stop at present
position.
When selecting " " with remote controller, its auto swing. Horizontal louver of
air conditioner will swing left&right automatically at the maximum angle.
When selecting " "
position swing. Horizontal louver of air conditioner will stop at that position as
shown by the icon to swing.
When selecting "
", its the circulating swing. Horizontal louver of
(swing angle is displayed dynamically)
air conditioner will swing circularly according to the angle as shown by the icon.
Note: There is no this function for the units. If press this key, the main unit will
click, but it also runs under original status.
HEALTH FUNCTION:
After pressing HEALTH button, remote controller will switch circularly as below:
"HEALTH""AIR""AIR HEALTH""no display"
When selecting "HEALTH" by remote controller, HEALTH function will be started up.
When selecting "AIR" by remote controller, AIR function will be started up.
When selecting "AIT HEALTH", AIR and HEALTH function will be started up.
When theres no display on remote controller, AIR and HEALTH function will be
turned off.
AIR function is applicable for some models.
10
X-FAN button
After pressing this button under cooling or dry mode, remote controller displays the
character of "X-FAN" and X-FAN function is started up. Press this button again to
cancel X-FAN function. The character of "X-FAN" will disappear.
Note:
After starting up X-FAN function, when turning off the unit, indoor fan will continue
to operate for a while at low speed to dry the residual water inside the indoor unit.
When the unit operates under X-FAN mode, press "X-FAN" button can turn off
X-FAN function. Indoor fan stops operation immediately.
TEMP button
Press this button can see indoor set temperature, indoor ambient temperature or
outdoor ambient temperature on indoor units display. Temperature is set circularly
by remote controller as below:
no display
Note:
Outdoor ambient temperature display may cant be selected for some models.
When indoor unit receives "
" signal, it displays indoor set temperature.
Only for the model whose indoor unit has dual-8 display.
10
TIMER button
At ON status, press this button once can set TIMER OFF. The character of HOUR
TIMER
ON. After each pressing of "+" or "-" button, time will increase or decrease half an
11
Note:
11
TURBO button
12
SLEEP button
13
LIGHT button
When pressing this button under cooling or heating mode, air conditioner will enter
into quick cooling or quick heating mode. The character of "TURBO" is displayed
on remote controller. Press this button again to exit turbo function and the character
of "TURBO" will be disappeared on remote controller.
Press this button under cooling, heating mode can start up sleep function.
" " icon will be displayed on remote controller. Press this button again to cancel
sleep function. " "icon on remote controller will be displayed.
Press this button can turn off the light for indoor units display. " " icon on remote
controller will disappear. Press this button again to turn on the light for indoor units
display. " " icon on remote controller will be displayed.
12
Operation guide
1. After putting through the power, press " ON/OFF " button on remote controller to
turn on the air conditioner.
2. Press " MODE " button to select your required mode: AUTO, COOL, DRY, FAN,
HEAT.
3. Press "+" or "-" button to set your required temperature. (Temperature cant be
adjusted under auto mode).
4. Press " FAN " button to set your required fan speed: auto, low, medium and
high speed.
5. Press "
" button to select fan blowing angle.
signal sender
battery
reinstall
remove
Cover of battery box
NOTICE
During operation, point the remote control signal sender at the receiving
window on indoor unit.
The distance between signal sender and receiving window should be no
more than 8m, and there should be no obstacles between them.
or wireless telephone; remote controller should be close to indoor unit during
operation.
Replace new batteries of the same model when replacement is required.
When you dont use remote controller for a long time, please take out the
batteries.
If the display on remote controller is fuzzy or theres no display, please
replace batteries.
13
Emergency operation
If remote controller is lost or damaged, please use auxiliary button to turn
on or turn off the air conditioner. The operation in details are as below:
conditioner. When the air conditioner is turned on, it will operate under
auto mode.
panel
aux. button
NOTICE:
14
Open panel
2
4
WARNING
operation environment, clean frequency can be increased.
15
16
Malfunction analysis
General phenomenon analysis
Please check below items before asking for maintenance. If the malfunction still
cant be eliminated, please contact local dealer or qualified professionals.
Phenomenon
Check items
Solution
Indoor unit
cant receive
remote
controllers
signal or
remote
controller
has no
action.
Remove obstacles.
No air
emitted
from
indoor
unit
Eliminate obstacles.
After reaching to set temperature, indoor unit will stop blowing out air.
17
Malfunction analysis
Phenomenon
Cooling
(heating)
effect is
not good.
Check items
Solution
Power failure?
Is plug loose?
Filter is dirty?
18
Malfunction analysis
Phenomenon
Odours are
emitted
Check items
Solution
Outdoor
unit has
vapor
Water
flowing
noise
Cracking
noise
19
Malfunction analysis
Error Code
When air conditioner status is abnormal, temperature indictor on indoor unit will
blink to display corresponding error code. Please refer to below list for identification of error code.
Error code
Indoor
display
Error code
Troubleshooting
H1
E5
H4
U8
H6
C5
F1
F2
Please contact qualified professionals for service.
Note: If there're other error codes, please contact qualified professionals for
service.
WARNING
When below phenomenon occurs, please turn off air conditioner and disconnect power immediately, and then contact the dealer or qualified professionals
for service.
Power cord is overheating or damaged.
Theres abnormal sound during operation.
Circuit break trips off frequently.
Air conditioner gives off burning smell.
Indoor unit is leaking.
Do not repair or refit the air conditioner by yourself.
If the air conditioner operates under abnormal conditions, it may cause
malfunction, electric shock or fire hazard.
20
At least 15cm
At least 15cm
At least 15cm
the
to
on
cti
tru
s
ob
At least 50cm
Sp
At least 30cm
e wall
ot
et
c
pa
eo
tio
uc
At
cm
At least 50cm
00
2
st
lea
the
to n
e
ac ctio
Sp stru
st
ob
lea
At cm
30
Drainage pipe
Space to th
tr
bs
At least 250cm
e
ac
le
0c
30
At
t
as
Space to the
obstruction
21
2 Screw driver
3 Impact drill
4 Drill head
5 Pipe expander
6 Torque wrench
7 Open-end wrench
8 Pipe cutter
9 Leakage detector
10 Vacuum pump
11 Pressure meter
12 Universal meter
Note:
14 Measuring tape
Indoor unit
1. There should be no obstruction near air
inlet and air outlet.
2. Select a location where the condensation water can be dispersed easily and
won't affect other people.
3. Select a location which is convenient to
connect the outdoor unit and near the
power socket.
4. Select a location which is out of reach
for children.
5. The location should be able to withstand
the weight of indoor unit and won't increase noise and vibration.
6. The appliance must be installed 2.5m
above floor.
7. Don't install the indoor unit right above
the electric appliance.
8. Please try your best to keep way from
fluorescent lamp.
1. Select a location where the noise and outflow air emitted by the outdoor unit
will not affect neighborhood.
2. The location should be well ventilated and dry, in which the outdoor unit
won't be exposed directly to sunlight or strong wind.
3. The location should be able to withstand the weight of outdoor unit.
4. Make sure that the installation follows the requirement of installation
dimension diagram.
5. Select a location which is out of reach for children and far away from animals
or plants.If it is unavoidable, please add the fence for safety purpose.
22
Grounding requirement
grounding with specialized grounding device by a professional. Please make
sure it is always grounded effectively, otherwise it may cause electric shock.
2. The yellow-green wire in air conditioner is grounding wire, which can't be used
for other purposes.
3. The grounding resistance should comply with national electric safety regulations.
4. The appliance must be positioned so that the plug is accessible.
5. An all-pole disconnection switch having a contact separation of at least 3mm in
6. Including an air switch with suitable capacity, please note the following table. Air
switch should be included magnet buckle and heating buckle function, it can
protect the circuit-short and overload. (Caution: please do not use the fuse only
for protect the circuit)
Air-conditioner Air switch capacity
0912K
16A
1824K
25A
23
0912K
Wall
Space
to the
wall
above
150mm
Left
55
Rear piping hole
Level meter
Wall
Wall
Space
to the
wall
above
150mm
Space
to the
wall
above
150mm
Left
55
Rear piping hole
Right
55
Rear piping hole
Level meter
Wall
Space
to the
wall
above
150mm
Right
55
Rear piping hole
24K
Wall
Space
to the
wall
above
150mm
Left
70
Rear piping hole
Level meter
Wall
Space
to the
wall
above
150mm
Right
70
Rear piping hole
2. Open a piping hole with the diameter of 55/70 on the selected outlet pipe
position. In order to drain smoothly, slant the piping hole on the wall slightly
downward to the outdoor side with the gradient of 5-10.
24
Note:
outdoor
55/
70
5-10
left
right
left
rear right
rear left
right
cut off
the hole
union nut
pipe
3. Adjust the torque force by referring to the following sheet. Place the open-end
wrench on the pipe joint and place the torque wrench on the union nut. Tighten
the union nut with torque wrench.
25
pipe
indoor pipe
4. Wrap the indoor pipe and joint of connection pipe with insulating pipe, and
then wrap it with tape.
insulating pipe
outlet pipe
drain hose
outlet
pipe
tape
drain hose
Note:
Add insulating pipe in the indoor
drain hose in order to prevent
condensation.
The plastic expansion particles are
not provided.
insulating pipe
screw
26
cable-cross
hole
power connection
wire
3. Remove the wire clip; connect the power connection wire to the wiring terminal
with wire clip.
09 12K
N(1)
18 24K
3
N(1)
yellowgreen
Note:
All wires of indoor unit and outdoor unit should be connected by a professional.
for a new one. Avoid extending the wire by yourself.
installation.
For the air conditioner without plug, an circuit break must be installed in the line.
The circuit break should be all-pole parting and the contact parting distance
should be more than 3mm.
27
connection pipe
drain hose
band
indoor and
outdoor power cord
gas
pipe
band
drain hose
upper hook
outdoor
sealing gum
lower hook of
wall-mounting frame
Note:
Do not bend the drain hose too excessively in order to prevent blocking.
28
Note:
drain vent
Drain hose
foot holes
foot holes
chassis
outdoor drain joint
29
screw
handle
union nut
liquid pipe
gas pipe
liquid
valve
gas valve
1. Remove the wire clip; connect the power connection wire and signal control
wire (only for cooling and heating unit) to the wiring terminal according to the
N(1)
18 24K
09 12K
N(1)
yellowgreen
N(1)
yellowgreen
handle
Indoor unit connection
Note: the wiring board is for reference only,please refer to the actual one.
30
brown blue
yellowgreen
N
POWER
wall
U-shaped curve
drain hose
Note:
The through-wal height of drain hose
shouldn't be higher than the outlet
pipe hole of indoor unit.
Slant the drain hose slightly downwards. The drain hose can't be
curved, raised and fluctuant, etc.
31
The water
outlet can't be
fluctuant
Vacuum pumping
Use vacuum pump
1. Remove the valve caps on
liquid valve
the liquid valve and gas
piezometer
Lo
Hi
valve and the nut of refrigas valve
gerant charging vent.
valve cap
2. Connect the charging hose refrigerant charging
of piezometer to the refri- vent
gerant charging vent of gas nut of refrigerant
valve and then connect the charging vent
other charging hose to the
vacuum pump
vacuum pump.
3. Open the piezometer cominner hexagon
pletely and operate for
spanner
10-15min to check if the
pressure of piezometer remains in -0.1MPa.
close
4. Close the vacuum pump
open
and maintain this status for
1-2min to check if the pressure of piezometer remains
in -0.1MPa. If the pressure decreases, there may be leakage.
5. Remove the piezometer, open the valve core of liquid valve and gas valve
completely with inner hexagon spanner.
6. Tighten the screw caps of valves and refrigerant charging vent.
7. Reinstall the handle.
Leakage detection
1. With leakage detector:
Check if there is leakage with leakage detector.
2. With soap water:
If leakage detector is not available, please use soap water for leakage detection.
Apply soap water at the suspected position and keep the soap water for more
than 3min. If there are air bubbles coming out of this position, there's a leakage.
32
Possible malfunction
The unit may drop, shake or emit noise.
(heating) capacity.
It may cause condensation and water
dripping.
(heating) capacity.
(heating) capacity.
Test operation
1. Preparation of test operation
Put through the power, press ON/OFF button on the remote controller to start
operation.
Press MODE button to select AUTO, COOL, DRY, FAN and HEAT to check
whether the operation is normal or not.
If the ambient temperature is lower than 16 , the air conditioner cant
startcooling.
33
Max length
Max height
of connecdifference
tion pipe
Cooling
capacity
Max length
Max height
of connecdifference
tion pipe
5000Btu/h
(1465W)
15
24000Btu/h
(7032W)
25
10
7000Btu/h
(2051W)
15
28000Btu/h
(8204W)
30
10
9000Btu/h
(2637W)
15
36000Btu/h
(10548W)
30
20
12000Btu/h
(3516W)
20
10
42000Btu/h
(12306W)
30
20
18000Btu/h
(5274W)
25
10
48000Btu/h
(14064W)
30
20
4. The additional refrigerant oil and refrigerant charging required after prolonging
connection pipe
After the length of connection pipe is prolonged for 10m at the basis of
standard length, you should add 5ml of refrigerant oil for each additional 5m
of connection pipe.
The calculation method of additional refrigerant charging amount (on the basis
of liquid pipe):
Additional refrigerant charging amount = prolonged length of liquid pipe
additional refrigerant charging amount per meter
When the length of connection pipe is above 5m, add refrigerant according to
the prolonged length of liquid pipe. The additional refrigerant charging amount
per meter is different according to the diameter of liquid pipe. See the
following sheet.
34
Liquid pipe(mm)
Gas pipe(mm)
9.52 or 12
15
20
6 or 9.52
16 or 19
15
50
12
19 or 22.2
30
120
16
25.4 or 31.8
60
120
19
250
250
22.2
350
350
35
Improper pipe expanding is the main cause of refrigerant leakage. Please expand
the pipe according to the following steps:
A: Cut the pipe
Confirm the pipe length according to
the distance of indoor unit and
outdoor unit.
Cut the required pipe with pipe cutter.
expander
pipe
pipe
pipe cutter
leaning
uneven
burr
Note:
"A" is different according to the
diameter, please refer to the sheet
below:
A(mm)
Outer diameter
(mm)
Max
Min
6 - 6.35(1/4")
1.3
0.7
9.52(3/8")
1.6
1.0
12-12.7(1/2")
1.8
1.0
15.8-16(5/8")
2.4
2.2
F: Inspection
Check the quality of expanding port.
If there is any blemish, expand the
port again according to the steps
above.
smooth surface
improper expanding
union pipe
leaning
pipe
36
damaged
surface
crack
uneven
thickness