Вы находитесь на странице: 1из 1

1:100 0

1m

2m

3m

1:50

0.5m

1m

1.5m

1:1

10mm

20mm

30mm

Bm07
811

4-Foundation Bolts
M20X250 N IS 5624

415

360

235

Type 2
301
Pile: Type C
450

548

5mm Air Hole(Optional)

300
16mm Plate

875
Pile: Type A

80

110
Foundation Bolts - refer Base
plate detail

650

Base Plate Type 1 Plan


Scale 1:10

Type 1

Type 1
449

50 mm non-shrink Grout

50

550

Pile: Type C

Type 2

2-ties 10

Bm06
8 -L bars 12

Base Plate Type A-Elevation

Pile: Type C

Scale 1:25

345

3500

NOTES:

Pile: Type C
345

Type 2
Type 1

1) Grade of Concrete M25 as per IS 456:2000


Each batch of concrete to be tested for strength using min 3

Type 1

Material:

Section BB
Scale 1:10

Pile: Type A

standard cubes at 7, and 28 days. Any discrepancy to be


promptly reported to the engineer-on-record.

Pile: Type C

2) Grade of Reinforcement in RCC to be Fe500 as per IS 1786


3) Grade of anchor bolts and nuts to be 4.6 as per IS 1367:P III

Type 1

Type 2

150

Sides to be casted against natural g

5) Base plates to have a min fy = 250 mpa.


6) For superstructure structural steel specifications, to refer
Scorpius Const. drawings

100

4) Anchor bolts on the drawing are only indicative. Actual to be


as per IS 5624:1993 Type A to G.

Bm07
2-ties 10

Bm06
6 -L bars 12

Bm06
8 -L bars 12
Bm04
12@150

Bm02
2-ties 10

Type 2

Type 1

Pile: Type C

7) Antishrink grout of min. 30 mpa to be used below base-plate.


8) Cover to concrete is 35mm

375

350
Steel-Concrete Interfaces specifications

2800

1) The structural member to be embedded in pile to be manu.


with controlled outward surface irregularities, for proper embed

Actuator Pile Cap General Arrangement

12@150
Bm05

Scale 1:25

100mm PCC

ment in wet concrete. The irregularities can be provided via


mandrelling the bottom end, or using bolts as shear studs.
2) Once the member is put into wet concrete for embedment,
absolute care must be taken to see it is not shaken, vibrated,
touched to prevent loss of friction with the pile till concrete set.
3) The borehole should be filled completely with concrete before

Section AA

the structural post is penetrated into it.

Scale 1:25

4) The plumbness of the post to be maintained by mechanical

500 dia cap

300 dia pile

300 dia pile

means, any adjustments to be made after min 14 days.


5) NO COMPOSITE ACTION OF STEEL+CONCRETE IS
TAKEN IN DESIGN.

Stiffner Plates as per


Scorpius Dwg.
3- 10 stirrups
4-Foundation Bolts
M16X250 N IS 5624

150

30
50
45
6- 6
Bm01
6- 12
1600

1600
10@200 stirrups

10@200 stirrups
Bm03

16 mm Plate

Bm06
4 -L bars 12
200

Base Plate Type 2 Plan


Scale 1:10
36

Scale 1:25

RCC Details Pile Type C


Scale 1:25
260

Type A to be used for


for all Tracker Blocks

Section BB
Scale 1:10

Design Complaint to the foll. Codes


IS 456-2000, IS 875, IS 800 LRFD
Correct Paper Size: A2

RCC Details Pile Type A

STRUCTURAL

6@300 stirrups

300

Bm02
2-ties 10

Drawing Title:
Drawn:
Checked:
Designed:

Foundation Details
1 of 1
Agami Engineering
Project:
A

04.10.16 IFC

Date: Description:
Revision History

MYT3
Client:
Scorpius Trackers

38/1997 Vakratunda Soc.,


GandhiNagar, Bandra (E),
Mumbai 400 051
P: +91-22-26432068
W: www.agamiengineering.com

JT
NP
SP/NP

Drawing No.:
S-MYT3-100
Project No.:
SCOR-MYT3