Академический Документы
Профессиональный Документы
Культура Документы
BERNAM
STREET
AR RO
AD
8400
8400
8400
8400
8400
8400
RECORD OF DRAWINGS
APPROVED BY BCA
ON 08 NOVEMBER 2002
6000 X 15000
HARDSTANDING
8400
8400
8400
8400
8400
115
2200
150
2820
115
9000
150
1000
2150
300
9000
4800
300
150
2700
2700
3000
700
2450
RAMP TO STRUCTURAL
ENGINEERS DETAIL
3000
300
VOID
FIRE/
SERVICE
LIFT 1
LOBBY
UP
DN
R=175
T=275
9000
150
2600
450
3285
200 900
8400
295
520 1300
FIRE/
SERVICE
LIFT 2
ELECT.
DUCT
450
DN
R=175
T=275
600
UP
LOBBY
TAS
F
8400
EXISTING GLAZING TO BE
RETAINED
30MM THK.
GRANITE CLADDING
TO EXISTING WALL
BY OTHERS
ALUCORE COMPOSITE
CLADDING SYSTEM
BY OTHERS
EXISTING GLAZING TO
BE RETAINED
DN
PLANTER
8400
SECTION LINE
THRU ATRIUM
ALUCORE COMPOSITE
CLADDING SYSTEM
BY OTHERS
MALE TOILET
SECTION LINE
THRU ATRIUM
BANK
30MM THK.
GRANITE CLADDING
TO EXISTING WALL BY OTHERS
VAULT
FS
6000 X 15000
HARDSTANDING
ALUCORE COMPOSITE
CLADDING SYSTEM
BY OTHERS
VAULT
HR
RECEPTION
8400
2700
FEMALE TOILET
NEW ROOF CANOPY ABOVE
60
SECURITY
CONTROL
ROOM
00
OWNER'S SIGNATURE :
ADDRESS :
DIRECTORY SIGNAGE
30MM THK.
GRANITE CLADDING
TO EXISTING WALL
BY OTHERS
PE 5
PE 7
PE 6
PE 8
LOBBY
PE 4
PE 9
PE 11
PE 10
PE 12
PE 13
LOBBY
LOBBY
350
2425
150
2925
2250
150
2655
7455
150
2250
350
2250
150
2655
150
7455
350
2250
350
2250
350
30MM THK.
GRANITE CLADDING
TO EXISTING WALL BY OTHERS
PE 14
150
2655
7515
150
2310
350
PE 3
STAIR C
SO
UP
PE 2
DRAWING TITLE :
PROJECT TITLE :
8400
DN
PE 1
UP
6000 X
150
HARDST 00
ANDING
SHOP
RO
AD
LOBBY
8400
30MM THK.
GRANITE CLADDING
TO EXISTING WALL BY OTHERS
AN
DN
350
6000
HARDX 15000
STAND
ING
30MM THK.
GRANITE CLADDING
TO EXISTING WALL
BY OTHERS
30MM THK.
GRANITE CLADDING
TO EXISTING WALL
BY OTHERS
PARAPET WALL
TRANSFORMER
WR
WR
TAS
2550
600
700
5350
NEW
MAIL
BIN
LOADING
BAY
600
MAIL AREA
BIN
CENTRE
2550
STAIR B
5400
6500
MDF ROOM
STAIR A
300
26400
9000
450
500
3000
BOUNDARY LINE
6500
TANJO
N
8400
300
26400
30MM THK.
GRANITE CLADDING
TO EXISTING WALL
BY OTHERS
550
G PAG
TAXI STAND
350
DN
26400
UP
ALUCORE COMPOSITE
CLADDING SYSTEM
BY OTHERS
"I
it
th
a
b
sh
ARCHITECTS :
PLANTER
"I
st
o
in
o
EXISTING GLAZING TO
BE RETAINED
30MM THK.
GRANITE CLADDING TO
EXISTING WALL BY OTHERS
"I
st
o
in
o
BOUNDARY LINE
6000 X 15000
HARDSTANDING
SCALE 1 : 200
STAGE :
99AWP1
BP
DRAWN :JP/JAMIE
PROJ. ARCH. : KCK
DRAWING NO.
SCALE 1:200
10
15
20 METRES
SCALE :
1 : 200
CHECKED :
99AWP1/BP/601
REV:
GPT
DIGITAL FILE NO
J1601BP00
"I
st
o
in
o
00
APPROVED :
KCK/PO
"I
st
o
in
o
"I
st
o
in
o
"I
st
o
in
o
"I
st
o
in
o
"I
st
o
in
o
"I
st
o
in
o