Вы находитесь на странице: 1из 20

TM

RM CON

AN ISO 9001:2008 COMPANY

ULTIMATE SHIELD TO YOUR WIRES & CABLES

A brand - that has BIS licence for both


Steel Conduit and Accessories
to be marked with

ISI Marked Rigid Steel Conduits


ISI Marked Fittings
Cable Tray & Raceways
Fan Box

Product Catalogue 2015

TM

ISI Marked Rigid Steel Conduits

RM CON
ULTIMATE SHIELD TO YOUR WIRES & CABLES

Black Painted for Medium Protection


Hot Dip Galvanized for High Protection

ISI Marked Steel Conduits fittings


Black Painted for Medium Protection
Hot Dip Galvanized for High Protection

Cable Tray & Raceways


Painted
Hot dip Galvanized

Fan Boxes

Contents
About us

Manufacturing Process

Coating Process

Properties of Steel Conduits

Our Rigid Steel Conduits Range

MS/GI ISI Marked Steel Conduit Fittings Range


Testing & quality control
Internal Beads Explainatory Note
Cable Tray
Fan Box

6-7
8-10
11
12-15
16

TM

RM CON
ULTIMATE SHIELD TO YOUR WIRES & CABLES

Manufacturing Process
Precision welded ERW (Electric Resistance Welding) conduit pipes are manufactured by the High Frequency process on
imported Automatic Plant. Here is a brief summarization of our manufacturing process:

HR Coils which are used as raw materials are fed into the rolling mill.

Thereafter formation into pipes, welding, cooling, sizing and cutting is done into required lengths by an automatic process.
The plant is equipped with Servo Control which ensures smooth and uniform welding.

Trademark RMCON and ISI are embossed at every one meter intervals.

Threading: Each length of tube is threaded at both the ends by Lanco Threaded Machines using ISO Metric Thread Chasers
having a pitch of 1.5mm & the length of thread is maintained within limits.

Coating Process:
a. Black Painting process for Medium Protection Rigid Steel Conduit.
b. Hot Dip Galvanizing Process for High Protection Galvanized Rigid Steel Conduit.
# Details of coating process given on the following page.

Finally the painted or galvanized pipes are labelled with stickers mentioning the RMCON Trademark, the ISI mark and
the size of outside diameter.

The pipes are then covered with plastic tube and packed with hessian cloth.
2

Coating Process
(a) Painting Process (for Medium Protection)
Painting is undertaken in respect of black medium protection Rigid Steel Conduits after the tube is formed from raw material HR coil with
the help of induction tube welding technology. Both the ends of the pipe are faced with the help of tools and the threads are formed at
both the ends of the pipe and at one end a suitable coupler is fixed. After cleaning, the pipes are then dipped into a painting tank in a
slanting manner so that the inner surface of the pipes also get painted and pipes are kept fully dipped into the tank till the bubbles / air
trapped inside the pipes is fully taken care of. After this the pipes are put vertically on stand again in a slightly slanting manner so that excess
paint get removed and gets drained into the painting tank. After this the paint is left to dry overnight and next day, after chemical and
physical inspection the painted pipes are packed into the bundles.

(b) Galvanization Process (for High Protection)


PROCESS FLOW CHART
Cleaning and
degreasing of Tubes

Post bath Chromating


To prevent
White rust problem

Pickling at 60C 80C with


Hydrochloric Acid &
Insulator

Water
Quenching

Galvanization in Zinc bath with


a) Molton mass purity > 98.5%
b) Aluminium added to decrease
rate of oxidation
c) Bath temp 440c - 460c

Rinsing in running
Water

Fluxing

*Additional Information -

Mass of Zinc Coating


Mass of Zinc coating shall not be less than 360gm/m2 (50 Micron) as determined from the average
.
Results of two specimen taken from the opposite ends of the tube selected for testing.
This mass of Zinc is measured by any one of the two method described below.
1 - Mass before and after Galvanization
2 - By way of magnetic method.
By measuring the thickness of coating with the help of Alcometer the mass of coating in gram per
square meter shall then be calculated by multiplying the thickness in mm by a factor 7047.

TM

RM CON
ULTIMATE SHIELD TO YOUR WIRES & CABLES

Properties of Steel Conduits:


Today's buildings are designed for life span 50-80 years and steel conduits last at least as long, making it the essential component of
modern electrical system. Steel conduit resists all common forms of wear and tear to ensure long lasting performance. Steel conduit
supports green building practices by helping reduce environmental impact throughout a buildings life cycle & contributes to
sustainability through waste reduction, resource conservation & reusability. Because of its ability to protect against electromagnetic
interference, you can rely on steel conduit for virtually all applications with highly sensitive computers & data.

Some of the major properties of our RMCON make Rigid Steel Conduit are as follows:
1. Durability
a.
b.
c.

Strength to withstand mechanical injury.


Superior Corrosion Protection.
Lifelong EMI shielding

2. Fire Resistance
a.
b.

GI & MS conduits are considered Non combustible by building codes.


Steel conduits do not add to fuel load or flame spread.

3. Sustainability
a.
b.
c.

Long service life- Some steel conduits have been in use for more than 60 years.
Ability to accommodate new conductors and additional circuits over time.
Total recyclability as steel is the world's most recycled material

4. Others
a.
b.
c.

Protection against impact at all temperatures.


Provides an excellent electrical path to ground, to eliminate the need for supplementary equipment
for grounding.
Compatible coefficient of expansion with most construction material.

The cost advantage of Steel Conduit


The ability to future proof the electrical system by using steel conduit lowers the total cost of the system during its life span. Today, the
need to replace or upgrade power, data and communications circuits can happen overnight. Requirements for more sophisticated
electronic equipment, increased power requirements or new applications can cause owners and tenants to demand changes in the
wiring of their plants, retail complexes or buildings. Steel conduit is adaptable and can accommodate these changes, making it easier
to pull out old wiring and install new systems. Steel conduit also provides the quickest and most efficient changeover or upgrading of
electrical conductors. It all adds up to make steel conduit the most cost-effective wiring method over time and this is only one of the
many benefits steel conduit provides.
4

Our Rigid Steel Conduit Pipes Range (Black Painted & Hot Dip Galvanized)

Black Painted for Medium


Protection. (Both Inner &
Outer Surfaces)

Provide The Most


dependable &
ultimate protection
to your

wires & cables


Hot Dip Galvanized for High
Protection. (Both Inner &
Outer Sufaces)

Technical details
Made from the best quality mild steel using the most modern high frequency Induction Tube Welding (Electric Resistance Welding)
Technology on automatic tube mill. RM CON rigid Steel Conduit Pipes are available in sizes from 20mm to 50mm with two type of
protective coatings against external influences.

Specifications Dimensional Requirements as per IS: 9537 (Part-II): 1981


NOMINAL SIZE IN MM

20

25

32

40

50

Outside Diameter (mm)

20

25

32

40

50

SIZE OF CABLE

SIZE OF CONDUIT
20 mm 25 mm

32 mm

40 mm 50 mm

NUMBER OF CABLES

Tolerance on outside diameter (mm)

-0.30

-0.40

-0.40

-0.40

-0.50

NOMINAL SIZE IN MM

Minimum Outside diameter (mm)

19.70

24.60

31.60

39.60

49.50

1.5

10

---

---

2.5

10

---

---

Wall Thickness
(a) Minimum (mm)

1.40

1.40

1.40

1.60

1.60

10

---

---

(b) Maximum (mm)

1.80

1.80

1.80

2.20

2.20

14

---

10

11

---

Screw Thread
(a) Pitch (mm)

1.50

1.50

1.50

1.50

1.50

16

---

(b) Length (mm)

151

191

191

191

221

25

35

50

(c) Profile
*ISO M = ISO METRIC

Maximum Capacity of RM CON Brand Rigid Steel

ISO M ISO M

ISO M

ISO M

ISO M

TM

RM CON
ULTIMATE SHIELD TO YOUR WIRES & CABLES

MS/GI IS - Marked Steel Conduit Fittings (IS -14768 Part-II : 2003)


RMCON Rigid Steel Conduit Fittings are ISI marked product.
RMCON Rigid Steel Conduit Fittings are much better than the Traditional Cast Iron moulded fittings.
The Comparison of RMCON ISI marked steel conduit fittings & Cast Iron Moulded Fittings is given below.
Sr. No.

Characterstics

RMCON

Cast Iron

(ISI Product)

(Moulded)

Basic Material

Mild Steel

Cast Iron

Impact Strength

Much Higher

Mild Strength

Inner & Outer Surface Finish

Superior

Inferior

(To protect damage to wires & cables)

Composition of Material

Standard

Varies from Manufacturer


to Manufacturer

Dimensional Accuracy

As per IS (Hence Fitment


with Pipe is better)

Variable

Adhesion with protective


coating (e.g. zinc)

Better & Uniform

No Set Parameter

Types of Fittings
Black Painted for Medium Protection. (Both Inner & Outer Surface)
Hot Dip Galvanized for High Protection. (Both Inner & Outer Surface)

Sizes
20mm to 50mm M.S. (Medium Mechanical Strength - Medium Protection)
20mm to 50mm G.I. (Medium Mechanical Strength - High Protection)

(1) Coupler As per IS 14768 (Part-II): 2003

(2) Solid Bend As per IS 14768 (Part-II): 2003

Size
20
25
32
40
50
X=
F=

X (Min)
25
25
25
35
35
Thread Length
Internal Dia (thread to thread)

all dimensions are in millimeter

F
18.5
23.5
30.5
38.5
48.5

Size
20
25
32
40
50

Radius
50
63
80
100
125

Thread Length
15
18
20
25
25

all dimensions are in millimeter

Preferred values of angle are 30, 60 and 90


The length of the thread shall be such as to allow compliance with
the performance claimed when fitted with conduit in according
6
to IS 9537 (Part II): 1981

(3) Junction Box As per IS 14768 (Part-II): 2003


Junction Box (Surface)
Size
(mm)
20
25

Spout O.D.
Collar Half
(mm)
Round Bottom
23.20
28.20

17.00 1
17.00 1

Length of
Spout (mm)

Depth of
Cavity (mm)

Inner Dia
of Cavity

Length of Screw
of Another Screw (mm)

Thickness
(mm)

20.00
24.00

28.00
31.00

60.00
60.00

50.00
50.00

1.6
1.6

Length of
Spout (mm)

Depth of
Cavity (mm)

Inner Dia
of Cavity

Length of Screw
of Another Screw (mm)

Thickness
(mm)

13.00
13.70

62.00
62.00

55.00
55.60

53.50
53.00

1.90
2.00

Length of
Spout (mm)

Depth of
Cavity (mm)

Inner Dia
of Cavity

Length of Screw
of Another Screw (mm)

Thickness
(mm)

13.00
13.70

72.00
72.00

55.00
55.60

53.00
53.50

1.90
2.00

Junction Box (Deep 2.5)


Size
(mm)
20
25

Spout O.D.
Collar Half
(mm)
Round Bottom
26.30
31.10

13.00 1
17.00 1

Junction Box (Deep 3)


Size
(mm)
20
25

Spout O.D.
Collar Half
(mm)
Round Bottom
26.30
31.10

13.00 1
21.00 1

Physical & Mechanical Properties :

Construction / Visual Appearance

There shall be no sharp edges, burrs or surface projections which can


damage the conductors or cables and are likely to cause injury to the
installer or user.

Durability of Marking

Marking shall be durable & legible.

Impact test

Shall show no sign of disintegration nor shall there be any crack visible to
normal or corrected vision without additional magnification & shall show
no reduction in properties.

External Influences test


protective coating

Conduits Fittings shall have adequate protection against external


influences.
1. Conduits Fittings (with Medium Protection) shall be dipped in chemicals
for 5 minutes and there should be not more than 2 blue colour spots on
each square cm. of the surface and no spot shall have a dimension large
than 1.5mm
2. Conduits Fittings (with High Protection) shall be immersed in a solution
of chemicals for 1 minute for 4 times. Samples shall show no precipitation
of copper which can not scrubbed off in running water, if necessary after
immersion, dip in a 10% solution of HCl for 15 seconds.

Uniformity of Zinc Coating

Sample shall withstand 4 times for one minute dips & shall show no
precipitation of copper.

Mass of Zinc Coating

Min avg. mass of zinc coating shall be 360g/m2

TM

RM CON
ULTIMATE SHIELD TO YOUR WIRES & CABLES

Testing & Quality Control


RMCON follows a very stringent quality assurance plan on every level of the Organization. Conduits & Accessories are
subjected to severe testing and quality control check both during and after production. The comprehensive quality control
testing guarantees that the conduit will perform satisfactorily in the application and ensures unmatched quality and
performance in industry. The quality control plan of RMCON comprises of raw material testing, on line testing & finally testing
of finished goods.

Raw Material Testing


(a) Each lot of Raw material is allotted a lot No so that traceability & its corelation with finished goods lot is available as &
when required in the factory
(b) Naked eye examination of H.R Coils of every lot is carried out to ensure that these are free from cut edges, Burrs,
Lamination or discoloration etc.
(c) The H.R Coil of every lot are routinely measured for wall thickness & width before the lot of Raw Material is approved to
be use for manufacturing the Rigid Steel conduits.

Online Testing of conduits


(a) Minimum Outer Diameter: Testing of Raw Conduits with the help of calibrated 'Go-No-Go' guages for maintaining the
proper minimum Outer Diameter is regularly done at every one hour interval.
(b) Maximum Outer Diameter: Testing of Raw conduits by calibrated 'Go-No-Go' guages is done for maintaining the
maximum Outer diameter at every one hour interval.
(c) Naked eye examination of Raw Tubes: Each & every raw conduit is checked with naked eye or with corrected vision so as
to ensure that the outer & inner surfaces are smooth & there are no open seams along the welding line & tool finish is
satisfactory.
(d) Controlling of Internal & External Beads: The internal Beads formations along the line of welding are controlled & kept
to the minimum possible extent without compromising with weld strength as the Internal bead is likely to damage the
Electrical Wires. Further the External Beads are removed by scrapping at the tool post.

Finished Goods Testing


Each and every lot of RMCON make steel conduits is tested as per scheme of testing & Inspection prescribed by Bureau of Indian
Standards (BIS). We have complete testing facilities for carrying out all the tests as per IS: 9537 (Part-2): 1981. The following tests are
routinely performed on steel conduits & fittings manufactured by us.
S.NO
1

Details of Test

Testing Equipments

Visual Inspection

Naked eye examination


with normal or corrected
vision

Remarks
The surface & edges of the
conduits must be smooth free
from burrs , pitting & edges
must not be sharp . Internal bead
must be minimal
(As per Clause 8.1 & 8.2 of IS 9537 (Part-I) : 1980

Marking

Naked eye examination

Dimensional

Naked eye examination

(a) Min. O.D

No Go Gauge
Go Gauge

As per Clause 7.2.1 of IS 9537 (Part-II): 1981


As per Clause 7.2.2 of IS 9537 (Part-II): 1981

Varnier Callipers or Micrometer


With least count 0.02mm

As per Clause 7.3 of IS 9537 (Part-II): 1981

(b) Max. O.D

c)Wall Thickness

(d) Uniformity of wall


Thickness
4

Screw Threads

Mechanical Strength
(a) Bend Test
(b) Compression Test

DoISO Metric Go & NO Go Gauge


for profile & Vernier Callipers
for length

As per Clause 6.0 of IS 9537 (Part-I): 1980

As per Clause 7.3.3 of IS 9537 (Part-II): 1981

As per Clause 7.4 of IS-9537 (Part-II): 1981

Bending Apparatus
Compression Testor

As per Clause 9.2 of IS-9537 (Part-II): 1981


As per Clause 9.3 of IS-9537 (Part-II): 1981

(a) Black Painted (for medium protection)

Blue colour spot Test

As per Clause 13.4.4 IS 9537 (Part-I): 1980

(b) Galvanized Coating (for higher protection)

Copper Deposition Test

As per Clause 13.4.5 IS 9537 (Part-I): 1980

Test of protective Coating

TM

RM CON
ULTIMATE SHIELD TO YOUR WIRES & CABLES

Test for checking the effectiveness of Protection against External Influences


as per IS: 9537 (Part-II): 1981 Specifications.
Steel Conduits shall have adequate protection against external influences. At RMCON we ensure that our Rigid Steel Conduits
are adequately protected against the corrosion & polluting substances from both inside & outside.

Blue Coloured Spot Test for Medium Protection:


Black coating on rigid steel conduits falls under medium protection type coating as per clause 5.1 of IS: 9537 (Part-2) 1981
specifications.
The testing for checking the effectiveness of this medium protection against the external influence on RMCON make black
coated rigid steel conduits is done through blue colour spot test as per BIS clause no 13.4.4 of IS: 9537 (Part-I) 1980.

Requisite Chemicals for the Test:


(a) Benzene (C6 H6)
(b)Potassium Ferricyanide [K3 Fe (CN)6]
(c)Ammonium Persulphate [(NH4 )2 S2 O8]
(d)Wetting agent e.g. AlkyInaphthaline Sulphonic Acid
Acceptance criteria:
The tested lot is certified CONFORMING if the tested samples do not show more than 2 blue coloured spot on each sq.cm of
the surface and no spot is of dimension larger than 1.5mm. However traces of rust on sharp edges, screw sizes and any
yellowish removable by rubbing is ignored.

Copper deposition Test for High Protection:


Hot dip galvanizing coating on Rigid Steel Conduits falls under high protection type coating as per clause no. 5.1 of IS:9537
(Part-2) 1981 specification.
The testing for checking the effectiveness of this high protection against the external influences on RMCON make Zinc
coated Galvanized steel conduits is done through copper deposition test as per BIS clause no. 13.4.5 of IS:9537 (Part-1)
1980

Requisite Chemicals for the Test:


(a) Carbon Tetra Chloride (CCl4)
(b) Sulphuric Acid (H2SO4)
(c) Crystalline Copper Sulphate

(d) Copper Hydroxide


(e) Distill water &Hydrochloric Acid (HCl)

Acceptance criteria:
The tested lot is certified CONFORMING if the tested samples show no deposition of copper which cannot be scrubbed off
in running water after immersion for 15 seconds in 10% Hydrochloric Acid. However copper deposition in traces on screw
threads is ignored.

10

11

TM

RM CON
ULTIMATE SHIELD TO YOUR WIRES & CABLES

Cable Tray
We are in process of manufacturing RMCON M.S. Cable Tray, RMCON Design & Manufacture Cable Trays for various industries: Gas
Companies, Oil Field, Malls, Petrochemicals, Power Plants and Metro Railway etc.
Our Product Range Includes
Perforated Cable Tray
Technical Details
H
20
20
20
20
20
20
20
20

x
x
x
x
x
x
x
x

W
50
75
100
150
200
300
450
600

x
x
x
x
x
x
x
x

H
20
20
20
20
20
20
20
20

T
1 mm - 2 mm
1 mm - 2 mm
1 mm - 2 mm
1 mm - 2 mm
1 mm - 2 mm
1 mm - 2 mm
1 mm - 2 mm
1 mm - 2 mm

25
25
25
25
25
25
25
25

x
x
x
x
x
x
x
x

50
75
100
150
200
300
450
600

x
x
x
x
x
x
x
x

25
25
25
25
25
25
25
25

1 mm - 2 mm
1 mm - 2 mm
1 mm - 2 mm
1 mm - 2 mm
1 mm - 2 mm
1 mm - 2 mm
1 mm - 2 mm
1 mm - 2 mm

40
40
40
40
40
40
40
40
40
40

x
x
x
x
x
x
x
x
x
x

75
100
150
200
225
250
300
450
600
750

x
x
x
x
x
x
x
x
x
x

40
40
40
40
40
40
40
40
40
40

1 mm - 2 mm
1 mm - 2 mm
1 mm - 2 mm
1 mm - 2 mm
1 mm - 2 mm
1 mm - 2 mm
1 mm - 2 mm
1 mm - 2 mm
1 mm - 2 mm
1 mm - 2 mm

50
50
50
50
50
50
50
50
50

x
x
x
x
x
x
x
x
x

100
150
200
300
450
600
750
900
1000

x
x
x
x
x
x
x
x
x

50
50
50
50
50
50
50
50
50

1 mm - 2 mm
1 mm - 2 mm
1 mm - 2 mm
1 mm - 2 mm
1 mm - 2 mm
1 mm - 2 mm
1 mm - 2 mm
1 mm - 2 mm
1 mm - 2 mm

75
75
75
75
75

x
x
x
x
x

300
450
600
900
1000

x
x
x
x
x

75
75
75
75
75

1 mm - 2 mm
1 mm - 2 mm
1 mm - 2 mm
1 mm - 2 mm
1 mm - 2 mm

Note :
All sizes are standard, any sizes can be offered
Width from 50mm to 1000mm
Thickness from 1mm to 2mm
Abbreviations
W- width of tray
B - Bend
T- Thickness of Sheet
L - Length of Tray
R Radius of Curve
H - Height of Tray
RH - Rung Height
RW - Wung width
C/D - Centre to centre distance between rungs

12

RMCON Ladder Type Cable Tray

1. Width from 150mm to 1000mm


2. Height from 40mm to 100mm
3. Thickness from 1.2 mm to 2.0mm
Ladder type outside / inside risers

1. Width from 100mm to 1000mm


2. Height from 40mm to 100mm
3. Thickness from 1.2 mm to 2.0mm
Ladder Type Cross

1. Width from 100mm to 1000mm


2. Height from 40mm to 100mm
3. Thickness from 1.2 mm to 2.0mm
Ladder Type TEE

1. Width from 100mm to 1000mm


2. Height from 40mm to 100mm
3. Thickness from 1.2 mm to 2.0mm
Ladder Type Reducers

13

1. Width from 100mm to 1000mm


2. Height from 40mm to 100mm
3. Thickness from 1.2 mm to 2.0mm

TM

RM CON
ULTIMATE SHIELD TO YOUR WIRES & CABLES

Technical Details
H
W
40
150
x
40
300
x

Note: All sizes are standard, any sizes can be offered


x
x

H
40
40

T
1.2 mm - 3 mm
1.6 mm - 2 mm

50
50
50
50

x
x
x
x

150
300
450
600

x
x
x
x

50
50
50
50

1.6 mm - 2 mm
1.6 mm - 2 mm
1.6 mm - 2 mm
1.6 mm - 2 mm

75
75
75
75

x
x
x
x

300
450
600
700

x
x
x
x

75
75
75
75

1.6 mm - 2 mm
1.6 mm - 2 mm
1.6 mm - 2 mm
1.6 mm - 2 mm

100
100
100
100
100
100

x
x
x
x
x
x

300
450
600
750
900
1000

x
x
x
x
x
x

100
100
100
100
100
100

1.6 mm - 2 mm
1.6 mm - 2 mm
1.6 mm - 2 mm
1.6 mm - 2 mm
1.6 mm - 2 mm
1.6 mm - 2 mm

Width from 100mm to 1000mm


Thickness from 1.2mm to 3mm
Abbreviations
W
B
T
L
R
H
RH
RW
C/D

Width of Tray
Bend
Thickness of Sheet
Length of Tray
Radius to Curve
Height of Tray
Rung Height
Rung Width
Centre to Centre distance
between rungs

14

Cable Tray Assembly System

Accessories for Cable Tray


Nuts, Bolts & Washers - Covers
Horizontal Elbow - Vertical Elbow
Hanger Clamps - Horizontal Tee
Wall Brackets - Coupler Plates
Cross - Reducer
Inward Band & Return Flange Cable Trays

Straight Flange Perforated Cable Trays


Ladder Type 90 & 45 Bend
Ladder Type Cross
Ladder Type Inside Risers
Ladder Type Outside Risers
Ladder Type Tee
Ladder Type Reducer etc.

Raceway

15

Width from 100mm to 1000mm


Height from 50mm to 100mm
Thickness from 1.0mm to 2.0mm

TM

RM CON
ULTIMATE SHIELD TO YOUR WIRES & CABLES

FAN BOX
DIAGRAM OF FAN BOX (TOP VIEW)

DIAGRAM OF FAN BOX (SIDE VIEW)

Specifications of MS Fan Box - RMCON Make


Material
: Mild Steel
Thickness
: Min. 1.62mm
Depth
: Min. 75mm
Distance from corner to corner
- 152.5mm
Length of the Rod
: 470mm
Diameter of the Rod
: 12mm
Protective coating either GI of Black Painted
Weight of the Fan Box
: 800gms 20grms
16

TM

RM CON
ULTIMATE SHIELD TO YOUR WIRES & CABLES

RMG STEELS PVT. LTD.


Manufacturing Unit :
B-51 Hosiery Complex, Phase-II, Extension,
Noida - 201305 (U.P)
Mob: +91 8130385451
Ph.: 0120-4225844, 4571152 Fax :
0120-4571153
Email : exports@rmgsteels.com
Web : www.rmgsteels.com

Branch Offices :
Delhi :
A-969/970 Ghrali, Dairy Colony,
Mayur Vihar, Phase-III,
Delhi - 110096

Mumbai:
Building A-10, Mankheli Naka,
Near Gaganan Petrol Pump
Unit No. - 19, Harihar Complex,
Bhiwadi (Thane),
Maharashtra - 421302
A N I S O 9 0 0 1 : 2 0 0 8 C E R T I F I E D C O M PA N Y

Kolkata
Nazirabad, Sonarpur
near Meghnath Saha Engg. College,
Karimpur, south-24, Paraganas,
Kolkata - 700150