CR1000

Datalogger de medio e controle


CR1000 Sistema de Controle e Medio / CR1000

Rugged Versatility
Multipurpose datalogger for
monitoring and control

Images
Descrio Tcnica
Especificaes
Compatibilidade

Documentos
Videos
Downloads
FAQs

Estudos de Caso
Articles & Press
Releases

Viso Geral
O CR1000 nosso datalogger mais amplamente usado. Pode ser usado em ampla gama
de funes de medio e controle. Robusto o bastante para condies extremas e
confivel suficiente para ambientes remotos, o mesmo se aplica para configuraes
complexas.

You created this PDF from an application that is not licensed to print to novaPDF printer (http://www.novapdf.com) 23/5/2016 15:44
1 de 12

CR1000: Datalogger de medio e controle

https://www.campbellsci.com.br/cr1000

O CR1000 baseia-se em nossos dataloggers CR10X e j foi posto em uso por todo o
mundo. Memria aumentada e mais canais de medio o tornam um poderoso
componente central em seu sistema de obteno de dados.
Read More

Benefcios e Caractersticas

Aplicaes ideais incluem clima com risco de incndio, sistemas mesonet, perfis
de vento, estaes meteorolgicas, qualidade do ar, Eto/agricultura, umidade do
solo, nvel/estgio da gua, aquicultura, previso de avalanche, reflectometria no
domnio do tempo, teste em veculo, SCADA e qualidade do ar

Comunicaes seriais com sensores seriais e dispositivos suportados via pares


de portas I/O

Coleta e armazena dados e controla perifricos como se fosse o crebro do seu


sistema

Energia flexvel e opes de comunicao tornam-o ideal para locais remotos

Memria de 4-MB pode ser expandida com sistemas de memria add-on

Suporta os protocolos DNP3, PakBus, Modbus e SDI-12

Compatvel com perifricos de expanso de canal permitindo a expanso do seu


sistema

Programa com LoggerNet, PC400 ou Atalho para se ajustar a sua configurao

Comunica-se atravs de vrias opes: TCP/IP, email, FTP, web server.

Gas Discharge Tube (GDT) protege as entradas

SRAM e relgio suportado por bateria que garante que dados, programas e horrio
preciso sero mantidos enquanto o datalogger estiver desconectado da fonte de
alimentao principal

Programa e controla no local com a adio da unidade do display e teclado


CR1000KD

Contm chip ASIC personalizado que aumenta a contagem dos pulsos, o controle
das portas e as capacidades das comunicaes seriais

Images

You created this PDF from an application that is not licensed to print to novaPDF printer (http://www.novapdf.com) 23/5/2016 15:44
2 de 12

CR1000: Datalogger de medio e controle

https://www.campbellsci.com.br/cr1000

3D/CAD Files:
cr1000 footprint (PDF)
CR1000 CAD Drawing (DXF)

Descrio Tcnica
The CR1000 consists of a measurement and control module and a wiring panel. This
datalogger uses an external keyboard/display and power supply. Low power consumption
allows the CR1000 to operate for extended time periods on a battery recharged with a
solar paneleliminating the need for AC power. The CR1000 suspends execution when
primary power drops below 9.6 V, reducing the possibility of inaccurate measurements.
The CR1000's module measures sensors, drives direct communications and
telecommunications, reduces data, controls external devices, and stores data and
programs in on-board, non-volatile storage. The electronics are RF shielded and glitch
protected by the sealed, stainless-steel canister. A battery-backed clock assures
accurate timekeeping. The module can simultaneously provide measurement and
communication functions. The on-board, BASIC-like programming language supports data
processing and analysis routines.

You created this PDF from an application that is not licensed to print to novaPDF printer (http://www.novapdf.com) 23/5/2016 15:44
3 de 12

CR1000: Datalogger de medio e controle

https://www.campbellsci.com.br/cr1000

The CR1000WP is a black, anodized aluminum wiring panel that is compatible with all
CR1000 modules. The wiring panel includes switchable 12 V, redistributed analog grounds
(dispersed among analog channels rather than grouped), unpluggable terminal block for 12
V connections, gas-tube spark gaps, and 12 V supply on pin 8 to power our COM-series
phone modems and other peripherals. The control module easily disconnects from the
wiring panel allowing field replacement without rewiring the sensors.
Originally, the standard CR1000 had 2 MB of data/program storage, and an optional
version, the CR1000-4M, had 4 MB of memory. In September 2007, the standard CR1000
started having 4 MB of memory, making the CR1000-4M obsolete. Dataloggers that have
a module with a serial number greater than or equal to 11832 will have a 4 MB memory.
The 4 MB dataloggers will also have a sticker on the canister stating 4M Memory.

Especificaes

Maximum Scan Rate: 100 Hz

Analog Inputs: 16 single-ended or


8 differential individually configured

Pulse Counters: 2

Switched Excitation Channels: 3 voltage

Digital Ports1: 8 I/Os or 4 RS-232 COM2

Communications/Data Storage Ports:


1 CS I/O, 1 RS-232, 1 parallel peripheral

Switched 12 Volt: 1

Input Voltage Range: 5 Vdc

Analog Voltage Accuracy:


(0.06% of reading + offset), 0 to 40C

Analog Resolution: 0.33 V

A/D Bits: 13

Power Requirements: 9.6 to 16 Vdc

Dimensions:
23.9 x 10.2 x 6.1 cm
(9.4" x 4.0" x 2.4")

Dimensions with CFM100 or NL115 attached:


25.2 x 10.2 x 7.1 cm
(9.9" x 4.0" x 2.8")

Weight: 1.0 kg (2.1 lb)

Protocols Supported: PakBus, Modbus, DNP3, FTP, HTTP, XML, POP3, SMTP,
Telnet, NTCIP, NTP, SDI-12, SDM

CE Compliance Standards to which Conformity is Declared: IEC61326:2002

Warranty: 3 years

Temperature Range

Standard: -25 to +50C

You created this PDF from an application that is not licensed to print to novaPDF printer (http://www.novapdf.com) 23/5/2016 15:44
4 de 12

CR1000: Datalogger de medio e controle

https://www.campbellsci.com.br/cr1000

Extended: -55 to +85C

Memory

Operating System: 2 MB flash

Battery-Backed SRAM for CPU Usage and Final Storage: 4 MB

Flash Disk (CPU) for Program Files: 512 kB

Typical Current Drain @ 12 Vdc

Sleep Mode: < 1mA

Active (w/o RS-232 communication):


1 to 16 mA typical

Active (w/RS-232 communication):


17 to 28 mA typical

1Certain

digital ports can be used to count switch closures.

I/O ports can be paired as transmit and receive for measuring smart serial sensors.

Compatibilidade
Sensors
With several channel types, the CR1000 is compatible with nearly every available sensor,
including thermocouples, SDI-12 sensors, and 4 to 20 mA sensors. A custom ASIC chip
expands its pulse count, control port, and serial communications capabilities. The
CR1000's I/O ports can be paired as transmit and receive, allowing serial communications
with serial sensors and devices.

Measurement & Control Peripherals


The CR1000 is compatible with all of our CDMs (requires an SC-CPI), SDMs, multiplexers,
vibrating wire interfaces, terminal input modules, and relays.

Communications
The CR1000 communicates with a PC via direct connect, Ethernet interfaces, multidrop
modems, short-haul modems, phone modems (land line, digital cellular, and voicesynthesized), RF telemetry, and satellite transmitters (Argos, High Data Rate GOES, and
Meteosat).
Data can be viewed on the CR1000KD Keyboard Display, the CD100 Mountable Display
with Keyboard, an iOS or Android device (requires LoggerLink), CD295 DataView II
Display, or a user-supplied PDA (PConnect or PConnectCE software required).
Compatible external data storage devices are the CFM100, NL115, and SC115.

Enclosures
The CR1000 and its power supply can be housed in any of our standard enclosures.

Power
Any 12 Vdc source can power the CR1000 datalogger. Power supplies commonly used

You created this PDF from an application that is not licensed to print to novaPDF printer (http://www.novapdf.com) 23/5/2016 15:44
5 de 12

CR1000: Datalogger de medio e controle

https://www.campbellsci.com.br/cr1000

with the CR1000 are the BPALK, PS150, and PS200. The BPALK provides eight
non-rechargeable D-cell alkaline batteries with a 7.5 Ah rating at 20C.
Both the PS150 and PS200 consist of a sealed rechargeable 7 Ah battery and a charging
regulator. Their battery should be connected to a charging source (either a wall charger or
solar panel). These two power supplies differ in their charging regulator. The PS150 has a
standard regulator and the PS200 has a micro-controller-based smart regulator. The
PS200's regulator provides two-step constant voltage charging and temperature
compensation that optimize battery charging and increases the batterys life.
Also available are the BP12 and BP24 battery packs, which provide nominal ratings of 12
and 24 Ah, respectively. These batteries should be connected to a regulated charging
source (e.g., a CH100 or CH200 connected to a unregulated solar panel or wall charger).

Software
CRBasic, the CR1000's full programming language, supports simple or complex
programming and many onboard data reduction processes. Compatible software includes:

Short Cut

PC200W

PC400 (version 1.2 or higher)

LoggerNet (version 3.0 or higher)

RTDAQ (version 1.0 or higher)

PConnect (version 3.1 or higher)

PConnectCE (version 2.0 or higher)

VisualWeather (version 2.0 or higher)

Documentos Relacionados
Product Brochures

CR1000 Measurement and Control System

CR1000 Specifications

Manuals

CR1000 Measurement and Control System

PakBus Networking Guide

Technical Papers

Benefits of Input Reversal and Excitation Reversal for Voltage Measurements

Preventing and Attacking Measurement Noise Problems

Voltage Accuracy, Self-Calibration, and Ratiometric Measurements

BACnet to Modbus Protocol Conversion (App. Note: 1M-C)

Irrometer 950R1-O/950T Radio Network (App.Note: 3MI-F)

AlphaGUARD Radon Monitor Interfaced with the CR1000 Datalogger

You created this PDF from an application that is not licensed to print to novaPDF printer (http://www.novapdf.com) 23/5/2016 15:44
6 de 12

CR1000: Datalogger de medio e controle

https://www.campbellsci.com.br/cr1000

Serial Sensors: Interfacing with CSI Dataloggers (App. Note Code: 2MI-V)

CF Card Information (3SM-F)

Case Studies

South Dakota: Irrigation System Update

Korea: Freezing Roads

Videos & Tutoriais

CRBasic | Common Errors 12:07

CR1000 Datalogger | Wiring


Panel - 7:18

Wiring a Datalogger to a
Multiplexer - 7:18

Multiplexer Programming with a


CR1000 Datalogger - 6:09

You created this PDF from an application that is not licensed to print to novaPDF printer (http://www.novapdf.com) 23/5/2016 15:44
7 de 12

CR1000: Datalogger de medio e controle

https://www.campbellsci.com.br/cr1000

CRBasic | Help System - 3:33

SDI-12 Sensors | Transparent


Mode - 7:13

SDI-12 Sensors | Watch or


Sniffer Mode - 3:25

CRBasic | Features - 11:09

Cellular Modems |
Troubleshooting - 15:29

PVS5120-Series Samplers |
CR1000 Connection (Part 3) - 3:33

RTMC Software | Getting Started


- 10:32

RTMC Pro Software | An


Introduction - 10:55

You created this PDF from an application that is not licensed to print to novaPDF printer (http://www.novapdf.com) 23/5/2016 15:44
8 de 12

CR1000: Datalogger de medio e controle

LoggerNet Software | Changing


Variables - 2:33

https://www.campbellsci.com.br/cr1000

CRBasic | Advanced
Programming - 6:50

Downloads
CR1000 OS v.29 (4.51 MB) 29-02-2016
Execution of this download installs the CR1000 Operating System and Compiler on your
computer. It also updates the CR1000 support files for the CRBasic Editor.
Note: This OS has crossed the 2 Meg CR1000 size limit for remote download. The
OS must be downloaded to the 2 Meg CR1000 via direct connect with the Device
Configuration Utility. All OS download methods are supported by the 4 Meg
CR1000.
Upgrading from versions prior to version 28 of the Operating System will reset the
dataloggers CPU drive. This is due to a change in the format of the file system from
FAT16 to FAT32. In order for the datalogger to operate correctly, as part of the upgrade,
the CPU drive is formatted to FAT32. Any programs stored and running from the CPU
drive will be lost. It is not recommended to update the dataloggers Operating System
over a remote connection where program control regulates the communication
equipment (turning it on or off, etc.). In these cases, an on-site visit and a backup using
DevConfigs backup utility is necessary to update the dataloggers Operating System.
Watch the Video Tutorial: Sending an OS to a Local Datalogger.
In all cases where the datalogger is being updated from an Operating System prior to 28,
the use of DevConfigs backup utility is recommended due to the CPU drive
being formatted using the new FAT32 format.
Adicione a Lista

Visualize o Histrico de Revises

You created this PDF from an application that is not licensed to print to novaPDF printer (http://www.novapdf.com) 23/5/2016 15:44
9 de 12

CR1000: Datalogger de medio e controle

https://www.campbellsci.com.br/cr1000

Device Configuration Utility v.2.12 (43.9 MB) 11-03-2016


A software utility used to download operating systems and set up Campbell Scientific
hardware. Also will update PakBus Graph and the Network Planner if they have been
installed previously by another Campbell Scientific software package.
Known Windows XP Issue:
This software release includes Campbell Scientific USB drivers that will not install on
Windows XP. To keep current with up and coming security requirements, the drivers have
been signed with a SHA-256 encryption which is not supported by Windows XP. Windows
XP users who have a need to install USB drivers for Campbell Scientific products can
contact Campbell Scientific for an alternate solution.
Adicione a Lista

Visualize o Histrico de Revises

Perguntas Frequentes Relacionadas


Number of FAQs related to CR1000: 178

Busca em PERGUNTAS FREQUENTES


Search
por pal

Expand All
1. Is there a way to check when the last background calibration was executed on a
CR1000?
2. How many tables can be defined for the CR1000?
3. How many RS-232 devices can the CR1000 handle?
4. Can HTTP and PakBus operate simultaneously?
5. How often is the lithium battery voltage measured by the datalogger?
6. How long can the cables be between networked dataloggers?
7. Is it possible to use LoggerNet RTMC while a datalogger is collecting data from a
serial sensor?
8. What does the PreserveVariables instruction do?
9. Is it possible to connect the CR800, CR850, CR1000, or CR3000 to a SCADA
system through a Modbus RS-485 protocol?
10. Can files on a PakBus datalogger be hidden?
View All Related FAQs (178)

Visit the FAQ Library

Estudos de Caso
Chile: Solar-Energy Assessment

10 deYou
12 created this PDF from an application that is not licensed to print to novaPDF printer (http://www.novapdf.com) 23/5/2016 15:44

CR1000: Datalogger de medio e controle

https://www.campbellsci.com.br/cr1000

Solar energy resource assessment projects are critical to the


successful siting of solar thermal power plants. Before a plant
is......read more
Flemish Pile Monitoring
Cofely Fabricom NV/SA (GDFSuez) has utilized Campbell Scientific
equipment on numerous projects in both the public and private sectors.
Campbell Scientific......read more

Washington AgWeatherNet
Washington State Universitys AgWeatherNet (AWN) is a large
automated network composed almost entirely of Campbell Scientific
products. AWNs purpose is......read more

California: Enhanced Climate Monitoring


Climate and its variations are estimated to have an effect of 10-20
percent of the trillion-dollar economy of the state......read more

Arkansas: Flood Warning


Hot Springs, Arkansas, is a history-rich city located adjacent to Hot
Springs National Park. The city is blessed with mountainous......read
more

Utah: Water-Supply SCADA System


In 2010, Trenton and Amalga, two northern Utah towns separated by
only a few miles, created a plan to design......read more

Florida: Water Diversion Control


In 1922, Florida began construction on what is now called the
Melbourne-Tillman Water Control District (MTWCD). They constructed
levees to......read more

Oregon: Interstate 5 Bridge


The Oregon Department of Transportation (ODOT), as part of its
statewide structural health monitoring (SHM) program, wanted to
improve its......read more

Explore All Case Studies

11 deYou
12 created this PDF from an application that is not licensed to print to novaPDF printer (http://www.novapdf.com) 23/5/2016 15:44

CR1000: Datalogger de medio e controle

https://www.campbellsci.com.br/cr1000

Articles and Press Releases


Newsletter Articles
Case Study: Preventing Road Damage from Freezing Conditions in South Korea
Powerful New Operating System for CR800, CR1000, CR3000 04-02-2015
Case Study: Solar-Energy Assessment in Chile 20-10-2014
Case Study: Florida Endangered Species 30-07-2014
Case Study: South Dakota Irrigation Update 30-07-2014
Case Study: Flood Warning in Arkansas 15-10-2013
Case Study: Preventing Road Damage from Freezing Conditions in South Korea
09-05-2013

Case Study: Florida Water Diversion Control 18-10-2012


Case Study: North Carolina Green Hotel 18-10-2012
New Operating System for CR800, CR1000, CR3000 12-07-2012
Case Study: Researching Glacier Retreat in the Andes 12-07-2012
Case Study: Station Provides Flood Warning & Road Weather Data 12-07-2012
Case Study: Water-Supply SCADA System 15-03-2012
Case Study: Post-Tensioned, Fiber-Reinforced Bridge 16-11-2011

Press Releases
NHRA Acceptance of Campbell Scientific Dataloggers 22-04-2008
More Versatile Channels, Increased Memory: Campbell Scientifics CR1000 Datalogger
06-09-2005

12 deYou
12 created this PDF from an application that is not licensed to print to novaPDF printer (http://www.novapdf.com) 23/5/2016 15:44

Вам также может понравиться