Академический Документы
Профессиональный Документы
Культура Документы
6
Residential Diaphragm Gas Meter
SPECIFICATIONS
KEY BENEFITS
Ready for remote reading and data
management
Ultra-compact design
ACCURACY CURVE
4
Error (%)
3
2
1
0
-1
-2
-3
-4
Qmin
2 Qmin
0.1 Qmax
Qmax
0.2 Qmax
But
3,0
2,5
Pro
ane
pan
2,0
Air (d
1,5
= 1)
NG (d = 0.
1,0
6)
0,5
0,0
0
d= density ratio
0,5
1,5
2,5
Flow rate (m3/h)
CONSTRUCTION
Measuring Unit
Totalizer
An outlet pipe.
All materials have been selected for their
superior resistance to chemicals and gas.
A back-run stop prevents the meter from
running backwards.
Casing
ACD G1.6 Parts
Aluminium casing.
Mechanical Transmission
A stuffing box transmits the movement of
the measuring unit to the totalizer.
Technical Specifications
ACD G1.6 Measuring Unit
QUALITY ASSURANCE
World-class engineering in a ISO 9001
certified design centre in Reims, France.
World-class manufacturing in a ISO 9001
certified operations unit in Buenos Aires,
Argentina, and Chongqing, China.
The following table shows all technical features affecting the measuring unit and the meter casing
Gas Type
Cyclic Volume
0.7 dm
Temperature Range
Gas:
Ambient:
Storage:
Maximum Operating
Pressure
Steel
0.5 bar (0.1 bar HTL version)
Aluminium 0.5 bar (1.0 bar optional)
Measuring Range
G0.6
G1
G1.6
Casing Material
Sheet steel
Aluminium alloy
Accuracy
Class 1.5
Approval
Flow Direction
Connections
Colour
-10C to +40C
-10C to +40C
-30C to +70C
Qmin
Qmax
Qmin
Qmax
Qmin
Qmax
0.016 m/h
1 m/h
0.016 m/h
1.6 m/h
0.016 m/h
2.5 m/h (3 m/h optional)
TOTALIZER FEATURES
c series
Smart ready, allowing for future AMR
capabilities
Itrons latest-generation mechanical index
meter comes standard with our Cyble
target, and can be upgraded in the field
to implement AMR and enable remote
reading via different communication
technologies.
ACD
G1.6
Mechanical
index,
inductive
pulse
AnyQuest &
EverBlu Cyble,
Cyble M-Bus,
Cyble Sensor
Base Meter
Index
Communication
Module
Meter Size
G0.6 / G1 / G1.6
N LNE-21197
Display
Transmission Rate
0.01 m3 / rotation
Transmission System
Cyble target
Mechanical Environment
M1
Electronical Environment
E2
o series
ACD
G1.6
Mechanical
index,
magnetic
pulse
Base Meter
Index
Asia version
AnyQuest &
EverBlu
Pulse
Communication
Module
Meter Size
G0.6 / G1 / G1.6
N LNE-21197
Display
Pulse Generator
Pulse Transmitter
Mechanical Environment
M1
Electronical Environment
E2
Weight
kg
Casing
Material
Entry
Distribution
Channel
A
mm
B
mm
C
mm
D
mm
c series
o series
c series
o series
Steel
Top
Asia
110
196
58
186
147
n/a
1.5
n/a
Aluminium
Top
SA
110
200
55.5
171
n/a
145
n/a
1.48
SA
130
200
55.5
171
n/a
145
n/a
1.55
SA
100
198
58
178
145
n/a
1.56
n/a
SA/Asia
110
198
58
178
145
n/a
1.59
n/a
Asia
110
175.5
55.5
171
n/a
139
n/a
1.41
Asia
130
175.5
55.5
171
n/a
139
n/a
1.41
Asia
169
175.5
48
176.5
150.5
n/a
1.5
n/a
Aluminium
Side
161
SA = South America
D
A
D
A
E
C
E
C
ACD G1.6
Top Entry
ACD G1.6
Asia Side Entry
B
F
B
F
E
C
OPTIONS
Outlet test pressure connector
Side entry connection
Ordering Information
Measuring range
Our company is the worlds leading provider of smart metering, data collection and utility software systems, with over
8,000 utilities worldwide relying on our technology to optimize the delivery and use of energy and water.
To realize your smarter energy and water future, start here: www.itron.com
ITRON ARGENTINA SA
Monseor Bufano 5010
B1766BIT - La Tablada
Prov. De Buenos Aires - Argentina
Phone: (54-11) 4480-4900
Fax:
(54-11) 4441-0223
While Itron strives to make the content of its marketing materials as timely and accurate as possible, Itron makes no claims, promises, or guarantees about the accuracy, completeness,
or adequacy of, and expressly disclaims liability for errors and omissions in, such materials. No warranty of any kind, implied, expressed, or statutory, including but not limited to
the warranties of non-infringement of third party rights, title, merchantability, and fitness for a particular purpose, is given with respect to the content of these marketing materials.
Copyright 2012, Itron. All rights reserved. GA-ACD-G1.6-EN-V3.0-2012.01