Instructions
for K3NV
Digital Weighing
Meter & Selection
why
- By Service Team, HYDERABAD
Mode
Key
1Sec -
- Shift Key -
- Up Key
- Escape
Key
- Reset /
Teach
1Sec +
Power On
1 Sec
SUSET
Setting Menu
SCALE
Scale Menu
A
A
SEt UP
1 Sec
Setup Menu
In - t
Input Range
bLC
B
FrE
Frequency
50
Input Range
C
SEt Up
Setup Menu
Opt
Option Menu
1 Sec
AvG
Average Processing
D
60008
StCnE
Startup Compensation
This setting is for Power on delay
i.e. 4 sec can be kept.
4
E
Power on delay 4 sec.
E
HYS
Hysteresis
Standard Output
F
LSEt.H
LSEt.L
AvG
OPt
By pressing
key we
have to go up to Scaling
menu
G
START OF
CALIBRATION
SCALE
1 Sec
InP.2
dSP.2
InP.1
Input Value 1
H
1 Sec
X.XXX
The display shows the input
voltage in mV corresponding to
Weigher empty from the load
cell.
InP.1
0
Set Value 0.
dEC-P
0.0.0.0.0
InP.2
SCALE
LSEt.L
1 Sec
This is called Linear Output
Range Low. That means, the
minimum (Tare) value to be
stored and this output will go to
PLC.
LSEt.L
Option menu
OPt
SCALE
InP.2
1 Sec
X.XXXX
InP.2
dsP.2
InP.1
SCALE
LSEt.H
1 Sec
XXXX
LSEt.H
OPt
tESt
SuSEt
1 Sec
Setting Value Menu
Su.HH
Su.H
XXXX
Su.L
This setting is for Weigher
Empty value.
XXXX
XXXX
Here we have to enter the
weigher lowest low value by
using Right and Up Keys
Su.HH
SuSEt
Run Mode
END OF
CALIBRATION
The display shows the weigher
value
+
Prot
1 Sec
Protect Menu
ALL
uPoFF
Protect off
uPoN
Protect ON
SuSEt
uPoN
Protect ON
U
ZEro
Zero setting Prohibit
uPoN
Protect ON
nn.rSt
uPoN
Protect ON
V
SECr
Security
ALL
Run Mode
END OF PARAMETER
SETTING