Operating

Instructions
for K3NV
Digital Weighing
Meter & Selection
why
- By Service Team, HYDERABAD

The following symbols were used throughout the


chapter for easy setting of parameters.

Mode
Key

1Sec -

Press briefly the mode key


single time.

- Shift Key -

Press briefly the shift key


single time.
Using the Up key select the
desired data.

- Up Key

Using the Up and Shift key


- select the desired data.

- Escape
Key

- Press briefly the Esc key single


time.

- Reset /
Teach

- Press briefly the Reset / Teach


key single time.

1Sec +

Press the mode key for about


1 second.

Press the Reset / Teach key


for about 1 second.

- Press both the Esc key and Up


key.

Power On

Run Mode display

1 Sec

SUSET

Setting Menu

SCALE

Scale Menu
A

A
SEt UP

1 Sec

Setup Menu

In - t

Input Range

bLC

Here we have to chose b LC


by pressing
key since
the input to the K3NV meter
from the load cell is 0 to 20
mv.

B
FrE

Frequency

50

Here we have to select 50 by


using
key since the power
line frequency is 50 Hz.
In - t

Input Range

C
SEt Up

Setup Menu

Opt

Option Menu

1 Sec

AvG

Average Processing

D
60008

Here we have to select the Movement average time depends


on the weigher in correspond to the communication between
the Omron display and PLC/ SCADA display in the computer.
If the values increases, the average movement / fluctuation
of the weighing display will increase. For Admix. It should be
60008 / 60016 and for Aggregates/ Cement it should be 1.

StCnE
Startup Compensation
This setting is for Power on delay
i.e. 4 sec can be kept.
4

E
Power on delay 4 sec.

E
HYS

Hysteresis

Here we have to select


5 for Agg, 2 for Cement
and 0.05 for Adm.
CoUT

Comparitive Output Pattern


nonAL

Standard Output

F
LSEt.H

LSEt.L

AvG

OPt
By pressing
key we
have to go up to Scaling
menu
G

START OF
CALIBRATION

SCALE

Scaling menu: From here the


starting of Calibration and
we have to ensure that the
weigher is empty.

1 Sec

InP.2

dSP.2

InP.1

Input Value 1

H
1 Sec
X.XXX
The display shows the input
voltage in mV corresponding to
Weigher empty from the load
cell.
InP.1

To get back to the I n P . 1 by


pressing
key once.
dsP.1

Display value 1 : Here we


have to set the weigher
minimum value that has been
calibrated for.

0
Set Value 0.

dEC-P

Setting menu for Decimal


position.

0.0.0.0.0

Here we have to set the


decimal position. No decimal
point for Agg. And cement
weighers. For Adm. as
shown above.
J

InP.2

By pressing mode key, we


have to go up to o P t and
from there by Pressing mode
key for 1 sec A v G appears.
From there by pressing mode
key once we have to go up to
L S E t . L

SCALE

LSEt.L

1 Sec
This is called Linear Output
Range Low. That means, the
minimum (Tare) value to be
stored and this output will go to
PLC.

The display shows the value


corresponding to zero weight
on the weigher.

LSEt.L

Option menu

OPt

By pressing mode key, we have


to go up to S C A L E for
calibrating the Max weight on the
weigher.

SCALE

InP.2

From here the calibration for


Max. load starts. We have to
ensure that the weigher loaded
with maximum weight to be
measured. In CP 30, for Agg.
1250 Kg; for Cem 400 Kg; and
for Adm. 6.000 Kg.

1 Sec

X.XXXX

Display shows the input


voltage in mV

InP.2

dsP.2

Display value 2 : Here we


have to set the weigher
maximum value that is to be
calibrated for.
XXXX

Enter the value corresponding to


Maximum weigher value. For
Agg. 1250 ; Cem 400 ; Adm
6000
N

InP.1

SCALE

From here we have to go up to o


P t by pressing mode key once
and from there by pressing mode
key for 1 sec, A v G appears.
From there by pressing mode key
once we have to go up to L S E t .
H.

LSEt.H

This is called Linear Output


Range High. That means,
the maximum value to be
stored and this output will go to
PLC.

1 Sec

XXXX

The display shows the value


corresponding to Max. weight
on the weigher. Agg. 1250 ;
Cem 400 ; Adm 6.000.

LSEt.H

OPt

tESt

SuSEt
1 Sec
Setting Value Menu

Su.HH

This setting is for the weigher


highest high value, that means
Max. value that the weigher can
be loaded.
XXXX

For Agg. 1250 ; Cem 400 ;


Adm 6.000
Here we have to give the
weigher Pre-maximum
value.

Su.H

XXXX

Su.L
This setting is for Weigher
Empty value.

XXXX

Here we have enter the value for


Agg. 5 ; Cem 2 ; Adm. 0.005
by using Up and Right arrow key.
Su.LL

Here we have enter the weigher


Lowest low value.
R

XXXX
Here we have to enter the
weigher lowest low value by
using Right and Up Keys
Su.HH

SuSEt

Run Mode
END OF
CALIBRATION
The display shows the weigher
value

Meter locking system Procedure


S
+

+
Prot

1 Sec
Protect Menu

ALL

All Key Protect

uPoFF
Protect off

uPoN

Protect ON

SuSEt

Setting value change Prohibit

uPoN

Protect ON
U

ZEro
Zero setting Prohibit

uPoN

Protect ON

nn.rSt

Max. and Min. value prohibit

uPoN

Protect ON
V

SECr
Security

Setup Menu Prohibited

ALL

Run Mode

END OF PARAMETER
SETTING