Вы находитесь на странице: 1из 8

Page 1 of 8

Autodesk Robot Structural Analysis Professional 2015

Fixed column base design


Eurocode 3: EN 1993-1-8:2005/AC:2009 + CEB Design Guide: Design of fastenings in
concrete

Ratio
0.99

GENERAL
1
Connection no.:
Connection name: Fixed column base

GEOMETRY
COLUMN
Section: 323 Dia
Lc =
5.00

[m]
[Deg]

Column length
Inclination angle

[mm]

Height of column section

[mm]

Width of column section

13

[mm]

Thickness of the web of column section

tfc =

13

[mm]

Thickness of the flange of column section

rc =

[mm]

Radius of column section fillet

121.93

[cm2]

Cross-sectional area of a column

=
hc =

0.0
323

bfc =

323

twc =

Ac =
Iyc =

14718.31
Moment of inertia of the column section
[cm4]
Metal
Steel
- 345 MPa
Material:
fyc =
345.00
[MPa]
Resistance
fuc =
448.00
[MPa]
Yield strength of a material

COLUMN BASE
lpd =

500

[mm]

Length

bpd =

500

[mm]

Width

tpd =

30
[mm]
Thickness
Material: Metal - Steel - 345 MPa
fypd =
345.00
[MPa]
Resistance
fupd =
448.00
[MPa]
Yield strength of a material

ANCHORAGE
The shear plane passes through the UNTHREADED portion of the bolt.
8.8
Class =
Anchor class
fyb =
640.00
[MPa]
Yield strength of the anchor material
fub =
800.00
[MPa]
Tensile strength of the anchor material
d=
As =

30
5.61

[cm2]

Bolt diameter
Effective section area of a bolt

[cm2]

Area of bolt section

Av =

7.07

nH =

nV =

[mm]

Number of bolt columns

Number of bolt rows


Horizontal spacing eHi = 135;135 [mm]
Vertical spacing eVi =

135;135 [mm]

mhtml:file://C:\Users\user.SANDUN\Documents\Autodesk\Output\ra_res.mht

9/5/2016

Page 2 of 8

Anchor dimensions
L1 =

60

[mm]

1000

[mm]

Washer
lwd =

50

[mm]

Length

bwd =

60

[mm]

Width

twd =

10

[mm]

Thickness

ls =

600

[mm]

Length

hs =

200

[mm]

Height

ts =

20

[mm]

Thickness

L2 =

STIFFENER

MATERIAL FACTORS
M0 =

1.00

Partial safety factor

M2 =

1.25

Partial safety factor

C =

1.50

Partial safety factor

SPREAD FOOTING
1500
1500
2000

[mm]
[mm]
[mm]

Spread footing length


Spread footing width
Spread footing height

Concrete
Class C30/37
fck =
30.00

[MPa]

Characteristic resistance for compression

L=
B=
H=

Grout layer
tg =

30

[mm]

Thickness of leveling layer (grout)

fck,g =

12.00

[MPa]

Characteristic resistance for compression

Cf,d =

0.30

Coeff. of friction between the base plate and concrete

WELDS
ap =

[mm]

Footing plate of the column base

as =

[mm]

Stiffeners

LOADS
Case: Manual calculations.
Nj,Ed =

-56.00

[kN]

Axial force

Vj,Ed,y =

10.00

[kN]

Shear force

Vj,Ed,z =

10.00

[kN]

Mj,Ed,y =

120.00

[kN*m]

Bending moment

Mj,Ed,z =

31.00

[kN*m]

Bending moment

Shear force

RESULTS
COMPRESSION ZONE
COMPRESSION OF CONCRETE
fcd =
20.00
[MPa]
fj =

40.00

[MPa]

Design compressive resistance


Design bearing resistance under the base plate

EN 1992-1:[3.1.6.(1)]
[6.2.5.(7)]

c = tp (fyp/(3*fj*M0))
c=
beff =
leff =

51
114

[mm]
[mm]

Additional width of the bearing pressure zone


Effective width of the bearing pressure zone under the flange

425

[mm]

Effective length of the bearing pressure zone under the flange

Ac0 =

485.20

[cm2]

Area of the joint between the base plate and the foundation

Ac1 =

4366.76

[6.2.5.(4)]
[6.2.5.(3)]
[6.2.5.(3)]
EN 1992-1:[6.7.(3)]

Maximum design area of load distribution


[cm2]
Frdu = Ac0*fcd*(Ac1/Ac0) 3*Ac0*fcd

EN 1992-1:[6.7.(3)]

Frdu =

EN 1992-1:[6.7.(3)]

j =

2911.17

[kN]

0.67

Bearing resistance of concrete


Reduction factor for compression

[6.2.5.(7)]

Design bearing resistance

[6.2.5.(7)]

fjd = j*Frdu/(beff*leff)
fjd =

40.00

[MPa]

mhtml:file://C:\Users\user.SANDUN\Documents\Autodesk\Output\ra_res.mht

9/5/2016

Page 3 of 8

Ac,n =

1971.98

[cm2]

Bearing area for compression

[6.2.8.2.(1)]

Ac,y =

940.18

[cm2]

Bearing area for bending My

[6.2.8.3.(1)]

Ac,z =

940.18

[cm2]

Bearing area for bending Mz

[6.2.8.3.(1)]

Fc,Rd,i = AC,i*fjd
Fc,Rd,n =

7887.92

[kN]

Bearing resistance of concrete for compression

[6.2.8.2.(1)]

Fc,Rd,y =

3760.71

[kN]

Bearing resistance of concrete for bending My

[6.2.8.3.(1)]

Fc,Rd,z =

3760.71

[kN]

Bearing resistance of concrete for bending Mz

[6.2.8.3.(1)]

COLUMN FLANGE AND WEB IN COMPRESSION


1.00
CL =
Section class
Wpl,y =
3538.31
Plastic section modulus
[cm3]
Mc,Rd,y =
1220.72
[kN*m]
Design resistance of the section for bending
hf,y =

288

EN 1993-1-1:[5.5.2]
EN1993-1-1:[6.2.5.(2)]
EN1993-1-1:[6.2.5]

[mm]

Distance between the centroids of flanges

[6.2.6.7.(1)]

[kN]

Resistance of the compressed flange and web

[6.2.6.7.(1)]

Fc,fc,Rd,y = Mc,Rd,y / hf,y


Fc,fc,Rd,y =

4241.55

Wpl,z =

3538.31

[cm3]

Mc,Rd,z =

1220.72

[kN*m]

hf,z =

288

Plastic section modulus


Design resistance of the section for bending

EN1993-1-1:[6.2.5.(2)]
EN1993-1-1:[6.2.5]

[mm]

Distance between the centroids of flanges

[6.2.6.7.(1)]

[kN]

Resistance of the compressed flange and web

[6.2.6.7.(1)]

Fc,fc,Rd,z = Mc,Rd,z / hf,z


Fc,fc,Rd,z =

4241.55

RESISTANCES OF SPREAD FOOTING IN THE COMPRESSION ZONE


Nj,Rd = Fc,Rd,n
Nj,Rd =

7887.92
[kN]
FC,Rd,y = min(Fc,Rd,y,Fc,fc,Rd,y)

Resistance of a spread footing for axial compression

FC,Rd,y =
3760.71
[kN]
FC,Rd,z = min(Fc,Rd,z,Fc,fc,Rd,z)

Resistance of spread footing in the compression zone

[6.2.8.3]

FC,Rd,z =

Resistance of spread footing in the compression zone

[6.2.8.3]

3760.71

[kN]

[6.2.8.2.(1)]

TENSION ZONE
STEEL FAILURE
Ab =

5.61
[cm2]
800.00
[MPa]
0.85
Beta =
Ft,Rd,s1 = beta*0.9*fub*Ab/M2

Effective anchor area

[Table 3.4]

Tensile strength of the anchor material


Reduction factor of anchor resistance

[Table 3.4]
[3.6.1.(3)]

Ft,Rd,s1 =

Anchor resistance to steel failure

[Table 3.4]

fub =

274.67

Ms =

[kN]

1.20

fyb =

640.00

Partial safety factor


[MPa]

CEB [3.2.3.2]

Yield strength of the anchor material

CEB [9.2.2]

Anchor resistance to steel failure

CEB [9.2.2]

Ft,Rd,s2 = fyb*Ab/Ms
Ft,Rd,s2 =

299.20

[kN]

Ft,Rd,s = min(Ft,Rd,s1,Ft,Rd,s2)
Ft,Rd,s =

274.67

PULL-OUT FAILURE
fck =
30.00

[kN]

[MPa]

Anchor resistance to steel failure

Characteristic compressive strength of concrete

EN 1992-1:[3.1.2]

fctd = 0.7*0.3*fck2/3/C
fctd =

1.35

Design tensile resistance

EN 1992-1:[8.4.2.(2)]

1 =

1.00

Coeff. related to the quality of the bond conditions and concreting conditions

EN 1992-1:[8.4.2.(2)]

2 =

1.00

Coeff. related to the bar diameter

EN 1992-1:[8.4.2.(2)]

[MPa]

fbd = 2.25*1*2*fctd
fbd =

3.04

[MPa]

Design value of the ultimate bond stress

EN 1992-1:[8.4.2.(2)]

hef =

1000

[mm]

Effective anchorage depth

EN 1992-1:[8.4.2.(2)]

[kN]

Design uplift capacity

EN 1992-1:[8.4.2.(2)]

Ft,Rd,p = *d*hef*fbd
Ft,Rd,p =

286.63

CONCRETE CONE FAILURE


hef =
365
[mm]

Effective anchorage depth

CEB [9.2.4]

NRk,c0 = 7.5[N0.5/mm0.5]*fck*hef1.5
NRk,c0 =
scr,N =

286.46

[kN]

Characteristic resistance of an anchor

CEB [9.2.4]

1095

[mm]

Critical width of the concrete cone

CEB [9.2.4]

mhtml:file://C:\Users\user.SANDUN\Documents\Autodesk\Output\ra_res.mht

9/5/2016

Page 4 of 8

ccr,N =

548

[mm]

Critical edge distance

CEB [9.2.4]

Ac,N0 =

22500.00

[cm2]

Maximum area of concrete cone

CEB [9.2.4]

Ac,N =

22500.00

[cm2]

Actual area of concrete cone

CEB [9.2.4]

Factor related to anchor spacing and edge distance

CEB [9.2.4]

Minimum edge distance from an anchor

CEB [9.2.4]

A,N = Ac,N/Ac,N0
A,N =
1.00
548
c=
[mm]
s,N = 0.7 + 0.3*c/ccr.N 1.0
s,N = 1.00

Factor taking account the influence of edges of the concrete member on the distribution of stresses in the concrete CEB [9.2.4]

ec,N = 1.00

Factor related to distribution of tensile forces acting on anchors

CEB [9.2.4]

re,N = 0.5 + hef[mm]/200 1.0


re,N = 1.00

Shell spalling factor

CEB [9.2.4]

ucr,N = 1.00

Factor taking into account whether the anchorage is in cracked or non-cracked concrete

CEB [9.2.4]

Mc =

Partial safety factor

2.16

CEB [3.2.3.1]

Ft,Rd,c = NRk,c0*A,N*s,N*ec,N*re,N*ucr,N/Mc
Ft,Rd,c =

132.62

[kN]

Design anchor resistance to concrete cone failure

SPLITTING FAILURE
hef =
1000

[mm]

Effective anchorage depth

CEB [9.2.5]

EN 1992-1:[8.4.2.(2)]

NRk,c0 = 7.5[N0.5/mm0.5]*fck*hef1.5
NRk,c0 =

1299.04

[kN]

Design uplift capacity

CEB [9.2.5]

scr,N =

2000

[mm]

Critical width of the concrete cone

CEB [9.2.5]

ccr,N =

1000

[mm]

Critical edge distance

CEB [9.2.5]

Ac,N0 =

57840.25

[cm2]

Maximum area of concrete cone

CEB [9.2.5]

Ac,N =

22500.00

[cm2]

Actual area of concrete cone

CEB [9.2.5]

Factor related to anchor spacing and edge distance

CEB [9.2.5]

Minimum edge distance from an anchor

CEB [9.2.5]

A,N = Ac,N/Ac,N0
A,N =

0.39

548
c=
[mm]
s,N = 0.7 + 0.3*c/ccr.N 1.0
s,N = 0.86

Factor taking account the influence of edges of the concrete member on the distribution of stresses in the concrete CEB [9.2.5]

ec,N = 1.00

Factor related to distribution of tensile forces acting on anchors

CEB [9.2.5]

re,N = 0.5 + hef[mm]/200 1.0


re,N = 1.00

Shell spalling factor

CEB [9.2.5]

ucr,N = 1.00

Factor taking into account whether the anchorage is in cracked or non-cracked concrete

CEB [9.2.5]

h,N = (h/(2*hef))2/3 1.2


h,N =

1.00

Coeff. related to the foundation height

M,sp =

2.16

Partial safety factor

CEB [9.2.5]
CEB [3.2.3.1]

Ft,Rd,sp = NRk,c0*A,N*s,N*ec,N*re,N*ucr,N*h,N/M,sp
Ft,Rd,sp =

202.19

[kN]

Design anchor resistance to splitting of concrete

CEB [9.2.5]

TENSILE RESISTANCE OF AN ANCHOR


Ft,Rd = min(Ft,Rd,s , Ft,Rd,p , Ft,Rd,c , Ft,Rd,sp)
Ft,Rd =

132.62

[kN]

Tensile resistance of an anchor

BENDING OF THE BASE PLATE


Bending moment Mj,Ed,y
leff,1 =

250

[mm]

Effective length for a single bolt for mode 1

[6.2.6.5]

leff,2 =

250
116
19.41

[mm]
[mm]
[kN*m]

Effective length for a single bolt for mode 2


Distance of a bolt from the stiffening edge
Plastic resistance of a plate for mode 1

[6.2.6.5]
[6.2.6.5]
[6.2.4]

19.41

[kN*m]

Plastic resistance of a plate for mode 2

m=
Mpl,1,Rd =
Mpl,2,Rd =

[6.2.4]

FT,1,Rd =

670.18

[kN]

Resistance of a plate for mode 1

[6.2.4]

FT,2,Rd =

391.91

[kN]

Resistance of a plate for mode 2

[6.2.4]

FT,3,Rd =
530.48
[kN]
Resistance of a plate for mode 3
Ft,pl,Rd,y = min(FT,1,Rd , FT,2,Rd , FT,3,Rd)

[6.2.4]

Ft,pl,Rd,y =

[6.2.4]

391.91

[kN]

Tension resistance of a plate

Bending moment Mj,Ed,z


leff,1 =

250

[mm]

Effective length for a single bolt for mode 1

[6.2.6.5]

leff,2 =

250
116
19.41

[mm]
[mm]
[kN*m]

Effective length for a single bolt for mode 2


Distance of a bolt from the stiffening edge
Plastic resistance of a plate for mode 1

[6.2.6.5]
[6.2.6.5]
[6.2.4]

19.41

[kN*m]

Plastic resistance of a plate for mode 2

[6.2.4]

Resistance of a plate for mode 1

[6.2.4]

m=
Mpl,1,Rd =
Mpl,2,Rd =
FT,1,Rd =

670.18

[kN]

mhtml:file://C:\Users\user.SANDUN\Documents\Autodesk\Output\ra_res.mht

9/5/2016

Page 5 of 8

FT,2,Rd =

391.91

Resistance of a plate for mode 2

[6.2.4]

FT,3,Rd =

530.48

[kN]
Resistance of a plate for mode 3
Ft,pl,Rd,z = min(FT,1,Rd , FT,2,Rd , FT,3,Rd)

[6.2.4]

Ft,pl,Rd,z =

391.91

[6.2.4]

[kN]

[kN]

Tension resistance of a plate

RESISTANCES OF SPREAD FOOTING IN THE TENSION ZONE


FT,Rd,y = Ft,pl,Rd,y
FT,Rd,y =

391.91

[kN]

Resistance of a column base in the tension zone

[6.2.8.3]

[kN]

Resistance of a column base in the tension zone

[6.2.8.3]

FT,Rd,z = Ft,pl,Rd,z
FT,Rd,z =

391.91

CONNECTION CAPACITY CHECK


Nj,Ed / Nj,Rd 1,0 (6.24)

0.01 < 1.00

verified

(0.01)

ey =

2143

[mm]

zc,y =

144

[mm]

Axial force eccentricity


Lever arm FC,Rd,y

[6.2.8.1.(2)]

[mm]

Lever arm FT,Rd,y

[6.2.8.1.(3)]

zt,y =
Mj,Rd,y =

203
145.53

[kN*m]

[6.2.8.3]

Connection resistance for bending

Mj,Ed,y / Mj,Rd,y 1,0 (6.23)

0.82 < 1.00

[6.2.8.3]
verified

(0.82)

ez =

554

[mm]

zc,z =

144

[mm]

Axial force eccentricity


Lever arm FC,Rd,z

[6.2.8.1.(2)]

[mm]

Lever arm FT,Rd,z

[6.2.8.1.(3)]

zt,z =
Mj,Rd,z =

203
183.45

[kN*m]

[6.2.8.3]

Connection resistance for bending

[6.2.8.3]

Mj,Ed,z / Mj,Rd,z 1,0 (6.23)

0.17 < 1.00

verified

(0.17)

Mj,Ed,y / Mj,Rd,y + Mj,Ed,z / Mj,Rd,z 1,0

0.99 < 1.00

verified

(0.99)

SHEAR
BEARING PRESSURE OF AN ANCHOR BOLT ONTO THE BASE PLATE
Shear force Vj,Ed,y
d,y = 0.49

Coeff. taking account of the bolt position - in the direction of shear

b,y = 0.49

Coeff. for resistance calculation F1,vb,Rd

[Table 3.4]

k1,y = 2.46

Coeff. taking account of the bolt position - perpendicularly to the direction of shear

[Table 3.4]

[Table 3.4]

F1,vb,Rd,y = k1,y*b,y*fup*d*tp / M2
F1,vb,Rd,y = 392.02

[kN]

Resistance of an anchor bolt for bearing pressure onto the base plate

[6.2.2.(7)]

Shear force Vj,Ed,z


d,z = 0.49

Coeff. taking account of the bolt position - in the direction of shear

b,z = 0.49

Coeff. for resistance calculation F1,vb,Rd

[Table 3.4]

k1,z = 2.46

Coeff. taking account of the bolt position - perpendicularly to the direction of shear

[Table 3.4]

[Table 3.4]

F1,vb,Rd,z = k1,z*b,z*fup*d*tp / M2
F1,vb,Rd,z = 392.02

[kN]

Resistance of an anchor bolt for bearing pressure onto the base plate

SHEAR OF AN ANCHOR BOLT


b =
0.25
Avb =
fub =
M2 =

7.07

[cm2]

800.00

[MPa]

[6.2.2.(7)]

Coeff. for resistance calculation F2,vb,Rd

[6.2.2.(7)]

Area of bolt section

[6.2.2.(7)]

Tensile strength of the anchor material

[6.2.2.(7)]

Partial safety factor

[6.2.2.(7)]

[kN]

Shear resistance of a bolt - without lever arm

[6.2.2.(7)]

[kN*m]

Characteristic bending resistance of an anchor

CEB [9.3.2.2]

Lever arm length

CEB [9.3.2.2]

Partial safety factor

CEB [3.2.3.2]

1.25

F2,vb,Rd = b*fub*Avb/M2
F2,vb,Rd =

112.19

M =

2.00

MRk,s =

1.76

lsm =

60

Ms =

1.20

Factor related to the fastening of an anchor in the foundation


[mm]

CEB [9.3.2.2]

Fv,Rd,sm = M*MRk,s/(lsm*Ms)
Fv,Rd,sm =

48.79

[kN]

Shear resistance of a bolt - with lever arm

CEB [9.3.1]

CONCRETE PRY-OUT FAILURE

mhtml:file://C:\Users\user.SANDUN\Documents\Autodesk\Output\ra_res.mht

9/5/2016

Page 6 of 8

NRk,c =

286.46

Design uplift capacity

CEB [9.2.4]

k3 =

2.00

[kN]

Factor related to the anchor length

CEB [9.3.3]

Mc =

2.16

Partial safety factor

CEB [3.2.3.1]

Fv,Rd,cp = k3*NRk,c/Mc
Fv,Rd,cp =

265.24

[kN]

Concrete resistance for pry-out failure

CEB [9.3.1]

CONCRETE EDGE FAILURE


Shear force Vj,Ed,y
VRk,c,y0 = 1596.06 [kN] Characteristic resistance of an anchor

CEB [9.3.4.(a)]

A,V,y =

0.67

Factor related to anchor spacing and edge distance

h,V,y =

1.00

Factor related to the foundation thickness

CEB [9.3.4.(c)]

s,V,y =

0.90

Factor related to the influence of edges parallel to the shear load direction

CEB [9.3.4.(d)]

ec,V,y =

1.00

Factor taking account a group effect when different shear loads are acting on the individual anchors in a group CEB [9.3.4.(e)]

,V,y =

1.00

Factor related to the angle at which the shear load is applied

CEB [9.3.4.(f)]

ucr,V,y =

1.00

Factor related to the type of edge reinforcement used

CEB [9.3.4.(g)]

Mc =

2.16

Partial safety factor

CEB [9.3.4]

CEB [3.2.3.1]

Fv,Rd,c,y = VRk,c,y0*A,V,y*h,V,y*s,V,y*ec,V,y*,V,y*ucr,V,y/Mc
Fv,Rd,c,y =

443.35

[kN]

Concrete resistance for edge failure

CEB [9.3.1]

Shear force Vj,Ed,z


VRk,c,z0 = 1596.06 [kN] Characteristic resistance of an anchor

CEB [9.3.4.(a)]

A,V,z =

0.67

Factor related to anchor spacing and edge distance

h,V,z =

1.00

Factor related to the foundation thickness

CEB [9.3.4.(c)]

s,V,z =

0.90

Factor related to the influence of edges parallel to the shear load direction

CEB [9.3.4.(d)]

ec,V,z =

1.00

Factor taking account a group effect when different shear loads are acting on the individual anchors in a group CEB [9.3.4.(e)]

,V,z =

1.00

Factor related to the angle at which the shear load is applied

CEB [9.3.4.(f)]

ucr,V,z =

1.00

Factor related to the type of edge reinforcement used

CEB [9.3.4.(g)]

Mc =

2.16

Partial safety factor

CEB [9.3.4]

CEB [3.2.3.1]

Fv,Rd,c,z = VRk,c,z0*A,V,z*h,V,z*s,V,z*ec,V,z*,V,z*ucr,V,z/Mc
Fv,Rd,c,z =

443.35

[kN]

SPLITTING RESISTANCE
Cf,d =
0.30
Nc,Ed =

56.00

Concrete resistance for edge failure

CEB [9.3.1]

Coeff. of friction between the base plate and concrete

[6.2.2.(6)]

[kN]

Compressive force

[6.2.2.(6)]

[kN]

Slip resistance

[6.2.2.(6)]

Ff,Rd = Cf,d*Nc,Ed
Ff,Rd =

16.80

SHEAR CHECK
Vj,Rd,y = nb*min(F1,vb,Rd,y, F2,vb,Rd, Fv,Rd,sm, Fv,Rd,cp, Fv,Rd,c,y) + Ff,Rd
Vj,Rd,y =

602.28

[kN]

Connection resistance for shear

Vj,Ed,y / Vj,Rd,y 1,0

0.02 < 1.00

CEB [9.3.1]
verified

(0.02)

Vj,Rd,z = nb*min(F1,vb,Rd,z, F2,vb,Rd, Fv,Rd,sm, Fv,Rd,cp, Fv,Rd,c,z) + Ff,Rd


Vj,Rd,z =

602.28

[kN]

Connection resistance for shear

CEB [9.3.1]

Vj,Ed,z / Vj,Rd,z 1,0

0.02 < 1.00

verified

(0.02)

Vj,Ed,y / Vj,Rd,y + Vj,Ed,z / Vj,Rd,z 1,0

0.03 < 1.00

verified

(0.03)

STIFFENER CHECK
Radial stiffeners
M1 =
5.97
Q1 =

[kN*m]

Bending moment acting on a stiffener

85.66

[kN]

zs =

56

[mm]

Location of the neutral axis (from the plate base)

Is =

4774.07

[cm4]

Moment of inertia of a stiffener

Shear force acting on a stiffener

d =

3.30

[MPa]

Normal stress on the contact surface between stiffener and plate

EN 1993-1-1:[6.2.1.(5)]

g =

21.71

[MPa]

Normal stress in upper fibers

EN 1993-1-1:[6.2.1.(5)]

=
z =

21.41

[MPa]

Tangent stress in a stiffener

EN 1993-1-1:[6.2.1.(5)]

37.24

[MPa]

Equivalent stress on the contact surface between stiffener and plate

EN 1993-1-1:[6.2.1.(5)]

max (g, / (0.58), z ) / (fyp/M0) 1.0 (6.1)

0.11 < 1.00

verified

mhtml:file://C:\Users\user.SANDUN\Documents\Autodesk\Output\ra_res.mht

(0.11)

9/5/2016

Page 7 of 8

WELDS BETWEEN THE COLUMN AND THE BASE PLATE


=

1.15

[MPa]

Normal stress in a weld

[4.5.3.(7)]

1.15

[MPa]

Perpendicular tangent stress

[4.5.3.(7)]

yII =

0.19

[MPa]

Tangent stress parallel to Vj,Ed,y

[4.5.3.(7)]

zII =

0.19

[MPa]

Tangent stress parallel to Vj,Ed,z

[4.5.3.(7)]

W =

0.90

Resistance-dependent coefficient

[4.5.3.(7)]

/ (0.9*fu/M2)) 1.0 (4.1)

0.00 < 1.00

verified

(0.00)

(2
(2

/ (fu/(W*M2))) 1.0 (4.1)

0.01 < 1.00

verified

(0.01)

/ (fu/(W*M2))) 1.0 (4.1)

0.01 < 1.00

verified

(0.01)

+ 3.0
+ 3.0

(yII2
(zII2

+
+

2))
2))

VERTICAL WELDS OF STIFFENERS


Radial stiffeners
=
39.57

[MPa]

Normal stress in a weld

[4.5.3.(7)]

39.57

[MPa]

Perpendicular tangent stress

[4.5.3.(7)]

II =

26.77

[MPa]

Parallel tangent stress

[4.5.3.(7)]

z =

91.72

[MPa]

Total equivalent stress

[4.5.3.(7)]

W =

0.90

Resistance-dependent coefficient

max (, II * 3, z) / (fu/(W*M2)) 1.0 (4.1)

0.23 < 1.00

[4.5.3.(7)]
verified

(0.23)

TRANSVERSAL WELDS OF STIFFENERS


Radial stiffeners
=
42.78

[MPa]

Normal stress in a weld

[4.5.3.(7)]

42.78

[MPa]

Perpendicular tangent stress

[4.5.3.(7)]

II =

33.22

[MPa]

Parallel tangent stress

[4.5.3.(7)]

z =

103.10

[MPa]

Total equivalent stress

[4.5.3.(7)]

W =

0.90

Resistance-dependent coefficient

max (, II * 3, z) / (fu/(W*M2)) 1.0 (4.1)

0.26 < 1.00

[4.5.3.(7)]
verified

(0.26)

CONNECTION STIFFNESS
Bending moment Mj,Ed,y
beff =

114

[mm]

Effective width of the bearing pressure zone under the flange

[6.2.5.(3)]

leff =

425

[mm]

Effective length of the bearing pressure zone under the flange

[6.2.5.(3)]

k13,y = Ec*(beff*leff)/(1.275*E)
k13,y =
leff =
m=

27

[mm]

Stiffness coeff. of compressed concrete

250
116

[mm]
[mm]

Effective length for a single bolt for mode 2


Distance of a bolt from the stiffening edge

[mm]

Stiffness coeff. of the base plate subjected to tension

[Table 6.11]

325

[mm]

Effective anchorage depth

[Table 6.11]

[mm]

Stiffness coeff. of an anchor subjected to tension

[Table 6.11]

[Table 6.11]
[6.2.6.5]
[6.2.6.5]

k15,y = 0.850*leff*tp3/(m3)
k15,y =
Lb =
k16,y = 1.6*Ab/Lb
k16,y =
0,y =

0.59

Column slenderness

[5.2.2.5.(2)]

Sj,ini,y =

22505.25

[kN*m]

Initial rotational stiffness

[Table 6.12]

Sj,rig,y =

185450.73

[kN*m]

Stiffness of a rigid connection

Sj,ini,y < Sj,rig,y SEMI-RIGID

[5.2.2.5]
[5.2.2.5.(2)]

Bending moment Mj,Ed,z


k13,z = Ec*(Ac,z)/(1.275*E)
k13,z =
leff =
m=

38

[mm]

Stiffness coeff. of compressed concrete

250
116

[mm]
[mm]

Effective length for a single bolt for mode 2


Distance of a bolt from the stiffening edge

[mm]

Stiffness coeff. of the base plate subjected to tension

[Table 6.11]

325

[mm]

Effective anchorage depth

[Table 6.11]

[Table 6.11]
[6.2.6.5]
[6.2.6.5]

k15,z = 0.850*leff*tp3/(m3)
k15,z =
Lb =
k16,z = 1.6*Ab/Lb

mhtml:file://C:\Users\user.SANDUN\Documents\Autodesk\Output\ra_res.mht

9/5/2016

Page 8 of 8

k16,z =

0,z =

[mm]

0.59

Stiffness coeff. of an anchor subjected to tension

[Table 6.11]

Column slenderness

[5.2.2.5.(2)]

Sj,ini,z =

49944.47

[kN*m]

Initial rotational stiffness

Sj,rig,z =

185450.73

[kN*m]

Stiffness of a rigid connection

Sj,ini,z < Sj,rig,z SEMI-RIGID

[6.3.1.(4)]
[5.2.2.5]
[5.2.2.5.(2)]

WEAKEST COMPONENT:
BASE PLATE - BENDING

REMARKS
Stiffeners extend outside contour of the base plate. 600 [mm] > 500 [mm]
0 [mm] >= -11 [mm]
Web weld thickness < 3 mm

Connection conforms to the code

mhtml:file://C:\Users\user.SANDUN\Documents\Autodesk\Output\ra_res.mht

Ratio 0.99

9/5/2016

Вам также может понравиться