HPR SERIES
HOW IT WORKS
(B). Water vapor condenses into a liquid for removal at the moisture
separator (C) by an Automatic Drain (D). The cold, dry air is reheated as
it passes through the Reheater (E). This prevents pipeline sweating. The
Static Condenser (F) eliminates the need for a cooling fan and simplifies
500 scfm.
GAIN EFFICIENCY
the system.
(E)
Reheater / Aux. Condenser
(A)
Evaporator
(C)
Moisture Separator
Air-powered products and processes operate best with clean and dry
compressed air. Productivity improves. Rejects decrease. Maintenance
personnel are able to be proactive and work from their schedule. The
entire facility runs smoothly and contributes to financial stability and
competitiveness.
(D)
Automatic
Condensate
Drain
(F)
Static
Condenser
(B)
Constant Pressure
Expansion Valve
All HPR Series dryers are built for durability, in a space-saving design.
Sturdy sheet steel is formed and protected by an epoxy-based
powder coat finish. Reliable reciprocating refrigeration systems use
Warm saturated air enters the air-to-air heat exchanger (A) where it is
precooled by the outgoing chilled air, and then passes through the air-
38F (+3C) pressure dew point. HPR Series can handle the pressure.
dryer by an automatic drain (D). Chilled dry air returns through the air-
to-air heat exchanger (A) where it is reheated before exiting the dryer.
compressed air at an affordable price. No fancy bells and whistles just dry air, pure and simple. The HPR Series non-cycling dryers were
designed to meet these demands.
(A)
Air-to-Air
Heat
Exchanger
(B)
Evaporator
(C)
Moisture
Separator
Capillary
Tube
Hot Gas
by-pass
Valve
(D)
Automatic
Condensate
Drain
Model
Refrigeration System
Timer
operated
304ss heat
115v/60/1 drain valve,
Panel
Copper
Constant exchanger, Capillary
High
Lighted
grounded, insulation mounted
R-134a,
tube-on- Pressure demister & Tube & Hot
Pressure
Compressor Dew point
8 foot,
valve,
drain valve
HFC
Reciprocating tube heat Expansion moisture Gas Bypass Fan
Cut-out
on/off switch indicator power cord strainer adjustments Refrigerant Compressors exchanger
Valve
separator
Valve
Cycling Switch
HPR5-10 & 15
HPR25-50
HPR75-150
HPR200-500
S
S
S
S
S
S
S
S
S
S
-
S1
S
S
S
S
S
S
S
S
S
S
S
S
S
-
S
S
-
S
S
S
S
S
S
CSA
Approved
S
S
S
S
Inlet/Outlet
scfm
Nm /min
npt. male
HPR5-10
HPR15
HPR25
HPR35
10
15
25
35
28
42
71
99
3/8
3/8
3/4
3/4
HPR50
HPR75
HPR100
HPR125
50
75
100
125
142
212
283
354
3/4
3/4
1
1
HPR150
HPR200
HPR250
HPR300
150
200
250
300
425
566
708
850
1
1-1/2
1-1/2
1-1/2
HPR400
HPR500
400
500
1133
1416
2
2
Power
Supply
115/1/60
460/3/60
Input Refrigerant
Power 2
kW
Height
Width
Depth
Shipping Weight
in
mm
in
mm
in
mm
lbs.
kg.
0.20
0.24
0.41
0.46
15
15
22
22
381
381
569
569
13
13
15
15
320
320
368
368
13
13
15
15
320
320
368
368
64
69
88
92
29
31
40
42
0.57
0.72
0.74
0.76
22
20
21
21
569
510
525
525
20
19
13
13
500
480
330
330
20
21
30
30
500
526
761
761
101
110
123
133
46
50
56
60
1.11
1.42
1.98
2.05
21
30
30
30
525
762
762
759
13
17
17
20
330
437
437
518
30
36
36
38
761
904
904
953
153
183
211
218
69
83
96
99
2.50
3.06
30
32
759
800
21
25
541
640
38
41
953
1052
232
262
105
119
R134a
Rated Flow Capacity - Conditions for rating dryers are in accordance with CAGI (Compressed Air and Gas Institute) Standard ADF 100: Refrigerated Compressed Air Dryers - Methods for Testing and Rating.
Conditions for rating above dryers are: compressed air at dryer inlet: 100 psig (7kgf/cm2) and 100F (38C) saturated; ambient temperature: 100F (38C); operating on 60 Hz power supply.
At rated conditions, pressure drop is less than 5 psi.
At 35F (2C) evaporator and 100F (38C) ambient
OPERATING CONDITIONS
To adjust dryer capacity for conditions other than rated, use Correction Factors (multipliers) from Tables 1 and 2.
Example: What is the capacity of a 200 scfm model when the compressed air at the inlet to the dryer is 150 psig
and 100F (38C), and the ambient temperature is 90F (32C)?
Answer: 200 scfm (rated flow from Specifications Table) x 1.13 (correction factor for inlet temperature and
pressure from
Table 1) x 1.06 (correction factor for ambient temperature from Table 2) = 240 scfm
Table 1: Dryer Sizing Chart
Inlet Air
Temp.
80
250
Ambient Air
Temperature
F
(C)
Correction
Factor
80
(27)
1.12
90
1.37
1.42
1.47
1.49
90
(32)
1.06
1.13
1.18
1.22
1.24
100
(38)
1.00
0.95
0.99
1.03
1.05
110
(43)
0.94
0.80
0.84
0.89
0.91
Max.
Min.
Max.
Min.
Max.
Min.
Models Inlet Air Inlet Air Inlet Air Inlet Air Ambient Ambient
Press. Press. Temp. Temp. Temp.
Temp.
psig
psig
5-10 - 50
250
30
120F
40F
110F
45F
75-500
232
10
120F
40F
110F
45F