Академический Документы
Профессиональный Документы
Культура Документы
Work Instruction
Sock Loading of Reformer Tubes
Revision Record
Issue
No
Revision
No
Date
Page
Edition
01
00
25-02-08
All
Established /Revised;
(Peter Cheshire)
Group Catalyst Manager
Description of Revision
Prepared
By
Approved
by
DAR
No.
GCM
Assigned
Mgr.
088/08
First issue
Group Reviewed;
(
)
Business Unit QUENSH
MR
( Nuchanart Lapasanoi )
Group QUENSH MR
Document :
WI-CH-16
Issue Date :
25 February, 2008
Accepted / Approved;
(
)
Business unit assigned
Manager
Revision Number :
00
Copy Number :
Issue Number :
01
Page :
1 of 3
CONTROLLED DOCUMENT
CR Asia Group
Work Instruction
Sock Loading of Reformer Tubes
1. Objective
This work instruction is to ensure that the task is performed safely with no impact on personnel and
environment.
2. Scope
This work instruction is applies to all CR Asia Companies.
3. Reference
None
4. Form
F-CH-04
F-CH-05
F-CH-06
F-CH-09
F-CH-16
5. Definition
None
6. Responsibility
6.1 Division Manager is responsible to review customer requirements and to assign subordinates
to perform work efficiently and safely. Keep monitoring operation performance, assist with problem
solving and liaise with the customer. Review reports after job completion.
6.2 Superintendent/ Engineer/Supervisor/Foreman is responsible to complete site survey and
specify scope of work to estimate and plan resources required (manpower, tools, equipment and
sub-contractor,) Supervise subordinates to ensure that all work is carried out efficiently and safely,
perform safety audits within work area and conduct safety toolbox talk before starting work.
6.3 Technician / worker are responsible to follow strictly on each step of this instruction and
perform work that assigned from their supervisor.
7. Procedure
7.1 Job Preparation & Safety
-
Document :
WI-CH-16
Issue Date :
25 February, 2008
Revision Number :
00
Copy Number :
Issue Number :
01
Page :
2 of 3
CONTROLLED DOCUMENT
CR Asia Group
Work Instruction
Sock Loading of Reformer Tubes
-
Conduct empty DP tests on every tube and record results. (Any variances need to be
checked out and rectified.) Ensure a clients representative is witness to all density pressure
testing & recording.
Document :
WI-CH-16
Issue Date :
25 February, 2008
Revision Number :
00
Copy Number :
Issue Number :
01
Page :
3 of 3
CONTROLLED DOCUMENT