ACTIVITY
No.
1 Check for all
concealed service
conduits
CONTROLLING
DOCUMENT
Drawing
Contract Specs.
BS 8000 Part 11
BS 5385
Drawing
Contract Specs.
BS 8000 Part 11
BS 5385
OF INSP./TEST
Verification, 100%
ACCEPTANCE CRITERIA
PERSON RESP.
AT LOCATION
Engineer /
Foremen/
Quality Engineer
Visual, 100%
Engineer /
Foremen/
Quality Engineer
Engineer /
Foremen/
Quality Engineer
Preparation of background/substrate/
backing/base
Setting out
Drawing
Contract Specs.
BS 8000 Part 11
BS 5385
Visual, 100%
Drawing
Contract Specs.
BS 8000 Part 11
BS 5385
Mfr's. data sheet
Visual, 100%
Engineer /
Foremen/
Quality Engineer
QC~PLAN.
Project No. & Name:
Name of Client/ Consultant:
SL
ACTIVITY
No.
5 Laying of tiles
CONTROLLING
DOCUMENT
Drawing
Contract Specs.
BS 8000 Part 11
BS 5385
Mfr's. data sheet
OF INSP./TEST
Visual, 100%
Curing
Drawing
Contract Specs.
Visual, 100%
Grouting
Drawing
Contract Specs.
BS 8000 Part 11
BS 5385
Mfr's. data sheet
Visual, 100%
ACCEPTANCE CRITERIA
- Appropriate bedding methods
- Proportioning and mixing of cement / organic
based adhesives as per spec. / mfr's.
instructions
- Control overall level of finished floor with
series of spot levels
- Line up floor tile joints with joints in
skirting tiles
- Where adjoining surfaces are in different
plane ensure the joints are continuous
- Stopping strips & divider strips installed
at change of floors
- Cut tiles neatly and accurately
- Joints made good around pipes & floor
drains
- Avoid cut courses
- Provide cut courses as wide as possible
- Surface irregularity within 3 mm
-Cure for period required
(3 days if not specified)
PERSON RESP.
AT LOCATION
Engineer /
Foremen/
Quality Engineer
Engineer /
Foremen/
Quality Engineer
Engineer /
Foremen/
Quality Engineer
QC~PLAN.
Project No. & Name:
Name of Client/ Consultant:
SL
ACTIVITY
No.
8 Movement joint
CONTROLLING
ACCEPTANCE CRITERIA
PERSON RESP.
DOCUMENT
Drawing
Contract Specs.
BS 8000 Part 11
BS 5385
Mfr's. data sheet
OF INSP./TEST
Visual, 100%
Protection
Drawing
Contract Specs.
BS 8000 Part 11
BS 5385
Mfr's. data sheet
Visual, 100%
Engineer /
Foremen/
Quality Engineer
10 Final Inspection
Drawing
Contract Specs.
Visual, 100%
Engineer /
Foremen/
Quality Engineer
- Appropriate sealant
- Fixing of sealant as per manufacturer's
data sheet
Tolerances
- Less than 6 mm wide 1 mm
- 6 mm or more 2 mm
AT LOCATION
Engineer /
Foremen/
Quality Engineer
QC~PLAN.
Ceramic Tiling (Wall & Floor)
Doc.No.CIVIL QC~Plan- 017/ REV. 0
RECORD
Daily tiling log
CIVIL QC~Form- 016-01/ REV 0
Ceramic Tiling (Wall & Floor)
CIVIL QC~Form- 017-01/ REV 0
Daily tiling log
CIVIL QC~Form- 016-01/ REV 0
Ceramic Tiling (Wall & Floor)
CIVIL QC~Form- 017-01/ REV 0
Daily tiling log
CIVIL QC~Form- 016-01/ REV 0
Ceramic Tiling (Wall & Floor)
CIVIL QC~Form- 017-01/ REV 0
QC~PLAN.
Ceramic Tiling (Wall & Floor)
Doc.No.CIVIL QC~Plan- 017/ REV. 0
RECORD
Daily tiling log
CIVIL QC~Form- 016-01/ REV 0
Ceramic Tiling (Wall & Floor)
CIVIL QC~Form- 017-01/ REV 0
--
QC~PLAN.
Ceramic Tiling (Wall & Floor)
Doc.No.CIVIL QC~Plan- 017/ REV. 0
RECORD
Daily tiling log
CIVIL QC~Form- 016-01/ REV 0
Ceramic Tiling (Wall & Floor)
CIVIL QC~Form- 017-01/ REV 0