Вы находитесь на странице: 1из 22

Consulting Sheet for Control Valve:

Sr.
No.

Description

Tag No.

Quantity

Units

Sr.
No.

Normal Flow Rate As per PDS

0.0

m3/ hr

Minimum Flow Rate As per PDS

0.0

m3/ hr

Maximum Flow Rate As per PDS

0.0

m3/ hr

Line Size (ID) As per PDS

inch

Schedule of the Pipe - From LL Details

40

MOC of the Line - From LL Details

CS

Static Head in Inlet Vessel

Static Head in Inlet Vessel

0.0586

Running Length

Kg/cm2

500

10 Viscosity of the Stream

0.18

cP

10

11 Viscosity of the Stream

0.0001

m2/s

11

12 Density of the Stream

586

kg/ m3

12

13 Destination Vessel Pressure fr PDS

0.7

Kg/cm2

13

14 Static Head in Destination Vessel

2.0

14

15 Static Head in Destination Vessel

0.1172

Kg/cm2

15

9.7

Kg/cm2

16

16 Operating Pressure in I/L Vessel PDS

17
17 Line Pressure Drop - Minimum Flow

#DIV/0!

Kg/cm2

18

18 Line Pressure Drop - Maximum Flow

#DIV/0!

Kg/cm2

19

19 Control Valve Pressre Drop- Minimum Flow

#DIV/0!

Kg/cm2

20

20 Control Valve Pressre Drop- Maximum Flow

#DIV/0!

Kg/cm2

16

Remarks:
Pressure Drop Available for Control Valve (Minimum Flow)
Pressure Drop Available for Control Valve (Maximum Flow)
The Pressure drop Value in PDS is OK.

#DIV/0!

PCV-1501/1502
(Flow Rate on Hold Status)

Description

Quantity

Entry

Exit

90Elbow ( Std Radius)

11

Values to be Entered

90Elbow ( Long Radius)

Linked Cell - Do not Enter Values

45Elbow ( Std Radius)

Result

45Elbow ( Long Radius)

Tee ( Entering Run): ( Due to FHP )

Tee ( Entering Branch):

Gate Valve (Open) + Foot Valve

Globe Valve ( Open)

Butterfly Valve(Open)

Check Valve

Strainer

Inter cooler

After Cooler

Level Tank

Line Filter

Flow Meter

Thermocouple

Orifices

Others

kg/ cm2 g
kg/ cm2 g

Cell Identity:-

Sr.
No.

Loss Description

Co-efficient

Entry

25

Exit

50

90Elbow ( Std Radius)

35

90Elbow ( Long Radius)

23

45Elbow ( Std Radius)

15

45Elbow ( Long Radius)

10

Tee ( Entering Run): ( Due to FHP )

60

Tee ( Entering Branch):

90

Gate Valve (Open) + Foot Valve

7.5

10

Globe Valve ( Open)

300

11

Butterfly Valve(Open)

12

Check Valve

100

13

Strainer

7.5

14

Inter cooler

300

15

After Cooler

300

16

Level Tank

300

17

Line Filter

300

18

Flow Meter

15

19

Thermocouple

15

20

Orifices

15

21

Others

11.55

Total Equivalent Length of the Fittings (m)

ttings (m)

Quantity

Eq. Length
(m)

1.3

2.5

11

19.6

5.8

0.8

0.5

18.3

13.7

1.1

45.7

0.0

5.1

0.4

0.0

0.0

0.0

0.0

0.8

0.8

0.0

114.8

Calculations for Control Valves:

Sr.
No.

Description

Normal Flow

Minimum
Flow

Flow rate

0.00

0.00

Static Head

1.00

1.00

Line Size (OD)

2.000

2.000

Line Size (ID)

0.05

0.05

MOC of the Line

CS

CS

Roughness Factor

0.046

0.046

Cross Section Area

0.002

0.002

Velocity of the Stream

0.000

0.000

Running Length

500.0

500.0

Equivalent Length

114.8

114.8

Total Length

614.8

614.8

10 Viscosity of the Stream

0.00014

0.00014

11 Density of the Stream

586.0

586.0

12 Reynolds No.

13 Friction factor

#DIV/0!

#DIV/0!

14 Pressure Drop

#DIV/0!

#DIV/0!

15 Pressure Drop

#DIV/0!

#DIV/0!

16 Pressure Drop

#DIV/0!

#DIV/0!

17 Pressure Drop

#DIV/0!

#DIV/0!

18 Pressure Drop

#DIV/0!

#DIV/0!

Maximum
Flow

UOM

0.00

m3/hr

1.00

2.000

Inch

0.05

CS
0.046
0.002

m2

0.000

m/s

500.0

114.8

614.8

0.00014

m2/s

586.0

kg/cm2

0
#DIV/0!
#DIV/0!

mlc

#DIV/0!

mlc

#DIV/0!

kg/cm2

#DIV/0!

kg/cm2

#DIV/0!

kg/cm2

Remarks