Вы находитесь на странице: 1из 1

GENERAL NOTES

1.

THIS BUILDING HAS BEEN DESIGNED TO SUPPORT ITS OWN DEAD LOAD PLUS:
LOADING
MEZZANINE
ROOF
DEAD LOAD
COLLATERAL LOAD
LIVE LOAD
WIND SPEED

4 kN/M.SQ.
0.15 kN/M.SQ.
4 kN/M.SQ.
160 km/h

2.

DESIGN CODES FOLLOWED ARE AS BELOW:


FRAMES ARE DESIGNED AS PER BS 5950-1:2000

3.

THE STRUCTURE UNDER THIS CONTRACT HAS BEEN


DESIGNED AND DETAILED FOR THE LOADS STIPULATED
AND SHOWN ON THESE DRAWINGS. ANY ALTERATIONS
TO THE STRUCTURAL SYSTEM OR THE REMOVAL OF
ANY COMPONENT PARTS OR THE ADDITION OF OTHER
CONSTRUCTION MATERIALS OR LOADS MUST BE DONE
WITH PRIOR CONSENT OF F A BAKER CONSULTANTS.

0.10 kN/M.SQ.
0.15 kN/M.SQ.
0.60 kN/M.SQ.
160 km/h

NOTES:1. ALL DIMENSIONS ARE IN mm.


2.
ROOF S.S. SCREWS TO BE FIXED THROUGH
EVERY CROWN
ALONG END BAYS, END LAPS ON EACH PURLIN
AND THROUGH
ALTERNATE CROWN FOR THE REMAINING BAYS
AND WALL SAME
AS ABOVE BUT S.S. SCREWS TO BE FIXED
THROUGH VALLEYS ONLY.
2. POP RIVETS TO BE FIXED THROUGH EVERY SIDE LAP.
3. SHEET TAPE TO BE APPLIED ALONG THE SIDE LAP / END LAP.

6.

F A BAKER CONSULTANTS ASSUMES NO RESPONSIBILITY


OR LIABILITY FOR THE COLUMN FOUNDATIONS,
CONSTRUCTION. FOUNDATIONS SHOULD BE DESIGNED
FOR THE GIVEN LOADS.

7.

WELDING DETAIL OF BUILT UP SECTIONS SHALL BE


OF ONE SIDE CONTINUOUS FILLET WELDING. THE
CONTINUOUS FILLET WELD SHALL BE AS PER APPROVED
WELDING PROCEDURE OF A.W.S

8.

STRUCTURAL MEMBERS WILL BE JOINED TOGETHER


TO ACHIEVE REQUIRED LENGTH BY FULL PENETRATION
GROOVE WELD AS PER THE REQUIREMENTS OF
APPROVED WELDING PROCEDURE FOR A.W.S. CODE
OR WITH THE BOLTED SPLICE CONNECTION AS
SHOWN IN THE DRAWINGS

9.

THE SLAB OR EDGE BEAM SHOULD BE SQUARE AND


LEVEL TO WITHIN 5 mm TOLERANCE.
ANCHOR BOLTS SHOULD BE SET TO THE GIVEN
DIMENSIONS AND PROJECTION, WITH MAXIMUM
DEVIATION OF 5 mm ANCHOR BOLT THREADS SHOULD
BE PROTECTED DURING CONCRETING OPERATION, OR
THOROUGHLY CLEANED AFTER POURING. ALL TEMPLATES
SHOULD BE REMOVED.

10.

ALL ANCHOR BOLTS DIAMETERS ARE IN mm. ANCHOR


BOLT PROJECTION MUST BE ACCORDING TO DESIGN AND
THREADS TO BE CLEAR OF DEBRIS.

4. PURLIN TAPE TO BE APPLIED ON EACH PURLIN / RUNNER


LONG INNER RIDGE, CURVE & DRIP FLG. AREA ONLY
5. FLASHING TO BE FIXED WITH POP RIVETS @ 300 mm C/C.
6. ALL THE DIMENSIONS TO BE CHECKED AND CONFIRMED BY
MAIN CONTRACTOR / CLIENT
7. ALL DRAWINGS SHALL BE READ IN CONJUNCTION WITH
RELATED STRUCTURAL AND ARCHITECTURAL

DRAWINGS.

S.S.. SCREW
(REFER NOTE)

PURLIN TAPE
ALUM. LINER SHEET

POP RIVET @ 300 mm C/C.


SHEET TAPE

ANCHOR BOLTS AND FOUNDATION BOLTS ARE SET BY


THE OWNER (OR THE CIVIL CONTRACTOR) IN
ACCORDANCE WITH F A BAKER CONSULTANTS "ISSUED FOR
CONSTRUCTION ANCHOR BOLT PLAN "DRAWING.
MAXIMUM ALLOWABLE TOLERANCE ARE AS FOLLOWS:a)

3 mm CENTER TO CENTER OF ANY TWO BOLTS


WITHIN AN ANCHOR BOLT GROUP.

b)

6 mm CENTER TO CENTER OF ADJACENT ANCHOR


BOLT GROUPS.

PURLIN TAPE
ALUM. LINER SHEET

c)

ELEVATION OF THE TOP OF ANCHOR BOLTS


12mm.

d)

MAXIMUM ACCUMULATION OF 6 mm PER 30


METERS ALONG THE ESTABLISHED COLUMN LINE
OF MULTIPLE ANCHOR BOLT GROUPS BUT NOT TO
EXCEED A TOTAL OF 25 mm.

e)

6 mm FROM THE CENTER OF ANY ANCHOR BOLT


GROUP TO THE ESTABLISHED COLUMN LINE
THROUGH THAT GROUP

f)

THE TOLERANCES OF PARAGRAPHS b, c, AND d


APPLY TO OFFSET DIMENSIONS SHOWN ON THE
PLANS, MEASURED PARALLEL AND PERPENDICULAR
TO THE NEAREST ESTABLISHED COLUMN LINE FOR
INDIVIDUAL COLUMNS SHOWN ON THE PLANS TO
BE OFFSET FROM ESTABLISHED COLUMN LINE.

12.

ALL HOT ROLLED MEMBERS AND PLATE CONNECTIONS SHALL


CONFORM TO BS EN 10025 S275 JR. SPECIFICATIONS OR EQUIVALENT,
WITH MINIMUM YIELD STRENGTH OF 265 N/mm2 .(U.N.O.)

13.

ALL PIPE STRUT / BOX SECTION SHALL CONFORM TO ASTM


A 53 GRADE A SPECIFICATIONS OR EQUIVALENT, WITH MINIMUM
YIELD STRENGTH OF 205 N/mm2 .(U.N.O.)

14.

ALL COLD FORMED SECTIONS SHALL BE FORMED FROM


GALVANIZED COILS CONFORMING TO
ASTM A-653 GRADE 50 SPECIFICATIONS OR EQUIVALENT WITH
MIN. YIELD STRENGTH OF 345 N/mm2. ALL COLD FORMED
SECTIONS WILL BE GALVANIZED AND REMAIN MILL FINISH

15.

ALL STEEL WORKS SHALL BE CORROSION PROTECTED WITH

ALUM. LINER SHEET

BRACING REACTIONS TO BE CONSIDERED WITH THE


MAIN FRAME REACTIONS.

PURLIN / RUNNER

SIDE LAP

TYPICAL FIXING DETAIL

SPECIFICATIONS:ROOF CLADDING:0.5mm THK POLYESTER COATED ALUMINUM TOP SHEET OF PROFILE


45/250 OR SIMILAR + 50 mm THK INJECTED POLYURETHANE
INSULATION DENSITY 35 Kg/m3 + ALUMINUM FOIL

WALL CLADDING:0.5mm THK POLYESTER COATED ALUMINUM TOP SHEET OF PROFILE


45/250 OR SIMILAR + 50 mm THK INJECTED POLYURETHANE
INSULATION DENSITY 35 Kg/m3 + ALUMINUM FOIL

CURVED EAVES CLADDING:45/250, 0.5mm THK. ALUMINUM POLYESTER COATED


+ 50mm THK.. FIBERGLASS LOOSE INSULATION (12-16Kg/m3)
+ ALUMINUM FOIL

PROFILE RIDGE:45/250 0.5mm THK. ALUMINUM POLYESTER COATED

FOLLOWING PAINTING SYSTEM:


a) SAND BLAST STEEL SURFACE TO SA21/5 ROUGHNESS
b) ONE COAT OF ZINC SILICATE PRIMER TO 60 DFT
c) 2 INTERMEDIATE COATS OF HB EPOXY 75 DFT EACH

INNER RIDGE:0.4mm THK. ALUMINUM POLYESTER COATED

TRIMS, FLASHING, & GUTTER,:-

d) ONE TOP COAT OF HW POLYTHENE TO 50 DFT


c) TOTAL PAINT SYSTEM THICKNESS - 260 M DFT
16.

ALL ANCHOR BOLTS SHALL BE OF GRADE 8.8 OR


EQUIVALENT AND GALVANIZED (6-8 MICRONS)
(GALVANIZING FOR PROTECTION DURING TRANSIT)

17.

BRACING RODS / ANGLES SHALL BE PROVIDED AT LOCATIONS


AS SHOWN IN THE DRAWINGS AND SHALL NOT BE REMOVED
OR ALTERED WITHOUT PRIOR CONSENT OF ENGINEERING DEPT.
OF F A BAKER CONSULTANTS.

ALL TRIMS & FLASHING CONSIDERED AS 0.4mm THK. ALUMINUM


POLYESTER COATED STD. COLOR

CLEADER ANGLE, SPACER, OVERLAP STRIP:1.5 THK. G.I. MILL FINISH.

PURLIN TAPE

ALL CONNECTION BOLTS AND ANCHOR BOLTS


ARE Gr. 8.8 BOLTS U.N.O. IN THE DRAWING.

5.

S.S.. SCREW
(REFER NOTE)

4.

Вам также может понравиться