I. Introduction
SA MP Malacca Strait is an oil and gas exploration
company headquartered in Jakarta. In conducting its
business EMP Malacca Strait SA safety, health and
environmental management in order to become an
exploration company and a leading oil and gas
production in Asia.
In an exploration and production of oil and gas
reliability of supporting facilities, such as compressors,
pressure vessels, pipes and so absolutely necessary. The
JOURNAL OF ENGINEERING POMITS Vol. 3, No. 2 (2014) ISSN: 2337-3539 (Print 2301-9271)
ready to be observed. Metalography test is used to
determine the microstructure. Cutting is done by
using saws manual / machine with water cooling.
Samples dimounting to facilitate sanding. Type of
mounting used is acrylic resin. Sanding is done using
silicon carbide sandpaper until 2000. grade polishing
done using alumina polishing paste. Testing is done by
using a solution of nital then cleaned under running
water and dry them with a hair dryer. Observations were
made using an optical microscope. On the computer
screen will appear the surface of the specimen with
various magnification bias is set. Hardness testing is
done by using a Rockwell C hardness tester with an
indenter made of diamond. This test uses the standard
ASTM C E18.Untuk rockwell adjust the force exerted
total of 150 kgf and will get value in units HRc
hardness. Tensile test was conducted to obtain the
mechanical properties of the material the bolt, so that
can know the cause of the failure by comparing and
analyzing the received bolt load with tensile test results
.. Tests conducted to determine the chemical
composition of the chemical composition of the material
broken bolt to be confirmed with specs stated in the
manual book given gas compressor. This test uses
optical emission spectrometer.
2
F-181
Observations macro
JOURNAL OF ENGINEERING POMITS Vol. 3, No. 2 (2014) ISSN: 2337-3539 (Print 2301-9271)
F-182
JOURNAL OF ENGINEERING POMITS Vol. 3, No. 2 (2014) ISSN: 2337-3539 (Print 2301-9271)
F-183
Table 5. Results of calculation of loading and load
voltage
JOURNAL OF ENGINEERING POMITS Vol. 3, No. 2 (2014) ISSN: 2337-3539 (Print 2301-9271)
The equivalent to ASTM A449 are quenched and
tempered medium carbon steel dengankadarkarbon 0.25
to 0.58. This material is dikhususkanuntuk screws that
require high tensile strength. Results of testing the
chemical composition using optical emission
spectrometer machine shown in Table 1 shows that
there are some chemicals that should not be on the bolt.
The presence of these elements will affect the
mechanical properties, especially hardness, with the
addition of alloy elements will increase the
hardenability of the material or hardened formability
and other properties to a certain extent be changed.
Observations at the macro level bolt conducted to
determine fracture pattern. Observations as shown in
figure 1 are early indications of cracking in the
outermost experiencing stress concentration then the
crack grows until finally the final fracture occurs. Based
on the characteristics of fatigue failure fracture pattern
shown in Figure 2 as the fracture characteristics
including unidirectional broken due to bending. To
determine the standard dimensions of the bolt was
measured using calipers can be determined that the
standard dimensions of Yag used in bolt proficiency
level is the standard American results of testing
hardness of the inside diameter to the outside using the
ASTM E18 method Rockwell C was found that the
average value of hardness in an area close to the fault is
36.09778 Hrc this value is greater than the value of
violence in areas far from the fault that is approximately
34.18667 Hrc this could have been caused by internal
stress due to compression loads in areas close to the
fault so that resulting in hardness ride. While the
standard ASTM A449 hardness value should range
between 19 to 30 HRc. Both in areas near fault and far
from the fracture hardness value exceeds the standard
that should be so we can say the violence is not
according to standards.
From the results of tensile tests using ASTM E8
value of the tensile strength of a maximum of 1206 MPa
and the strength values luluhnya 1147 MPa this value so
far in excess of standard given ASTM A449 is the
tensile strength of a maximum of 725 MPa and strength
luluhnya at 560 MPa it could be due to other elements
that should not be on the bolt and also the influence of
the internal stress that causes its strength values are
higher than the specifications in ASTM A449 test
results using ASTM E3-98 microstructure is shown in
Figure 3 are the traits of microstructure tamper medium
carbon martensitic steel [3], so that it can be said
microstructure broken bolt in accordance with the
specifications given.