Вы находитесь на странице: 1из 1

Liquid Sulphur

Temperature

145.0

Pressure

0.0000

kPag

Mass Flow

2762.5

kg/h

Thermal Conductivity

0.2440

W/m-K

Molecular Weight

32.07

Mass Density

1752

Master Comp Mole Frac (S_Liq_150)

Assume delta T heat loss for stream is 5 DegC


Stream Heat Loss Engy
Heat Flow

kg/m3

5.690

kW

Temperature
Pressure

1.0000

140.0
0.0000

C
kPag

Stream Heat Loss


Engy

Liquid
Sulphur

1
Stream
Heat
Loss

Melting point for liquid sulphur is 115.21 DegC at atmosphric conditions.


Use tank temperature of 145 DegC with margin over melting point.

1.0000
160.1

Pressure

517.0

kPag

Mass Flow

61.82

kg/h

LP
Steam
Supply

Pressure Drop

Heat Flow

36.24900

Inside Diameter (Inside Diameter_1)

kW

Outside Diameter (Outside Diameter_1)

Tank
Heating
Coil

LP Steam
Condensate

From tank heat loss calculations use a duty of


36.249 kW for 1" insulation and no wind.

1" Pipe
#1

psi

100.0

ft

0.9570

in

1.315

in

1" Pipe
#2

Tank Heating Coil


Engy

1.0000

Operating pressure of LP steam reported at 517 kPag.


Assume supply is saturated.

0.0055

Pipe Length (Pipe Length_1)

Tank Heating Coil Engy

Temperature

Master Comp Mole Frac (H2O)

1" Pipe #2

Tank heat loss of 36249 W

LP Steam Supply
Vapour Fraction

3
LP Steam Condensate
Vapour Fraction

0.0000

Temperature

158.7

Pressure

496.3

kPag

Molar Flow

1947

m3/d_(gas)

1" Pipe #2
Engy

Recommend insulating tank with 64 mm (2.5 inches) for heat


conservation.

2
1" Pipe #1
Engy
1" Pipe #1
Pressure Drop
Pipe Length (Pipe Length_1)
Inside Diameter (Inside Diameter_1)
Outside Diameter (Outside Diameter_1)

1.011

psi

100.0

ft

0.9570

in

1.315

in

Sat Oct 22 16:31:32


Case:
2016
C:\Users\Greg\Documents\Gregs Sherritt Files\Varadero Sulphur Plant Refurbishment\SulphurTank Heat Coil\Sizing to Tank Heating Coil.hsc
Flowsheet: Case (Main)