Вы находитесь на странице: 1из 47

CONTROL SOLUTION & ACCESSORIES

CONTROL SOLUTION
& ACCESSORIES
2016

2016

LG HVAC
SOLUTION

LG Electronics
http://www.lg.com
http://partner.lge.com
Copyright 2016 LG Electronics. All rights reserved.

Distributed by

EUROPE SALES
INFRASTRUCTURE

GLOBAL PRODUCTION SITE

Europe B2B Regional Head Office


National Sales Office
Air Conditioning Academy

Tianjin, China

European Distribution Center

Gebze, Turkey

Noida, India

Changwon & Jeonju, Korea


Qingdao, China

Europe Energy Lab


Riyadh, Saudi Arabia

Production Site

Haiphong, Vietnam
Pune, India

Rayong, Thailand
Manaus, Brazil

LG Electronics products sold in Europe are Made in Korea (Except for ceiling suspended unit).

LG Energy Labs in Europe


Committed to to meet all requirements regarding energy efficiency and environmental
demands, LG has been running Energy Lab. LG Energy Lab is an innovative site dedicated to
commercial and residential products in heating, ventilation and the latest energy efficient
air conditioning solutions. Also as a showcase, LG Energy Lab is equipped with complete
monitoring and control systems. The performance of all products will be tracked and analyzed
by a team of Research and Development engineers based in France, Finland and Korea,
ensuring efficiency and reliability during the whole product lifecycle.

European Air Conditioning Distribution Center


LGs European Air Conditioning Distribution Center is located in Oosterhout, the Netherlands.
Supplying and delivering products all over Europe, this distribution hub has contributed
to smooth and rapid delivery, direct shipping for smaller orders and delivery tailored to air
conditioners. The hub tries to manage inventory efficiency by taking advantage of LG EUs
established inventory pool.

TOTAL HVAC SOLUTION PROVIDER


Ever since manufacturing Koreas first home grown air conditioner
in 1968, LG has remained at the forefront of air conditioning
innovation. LG has been the worlds top selling manufacturer of
residential air conditioning solutions. In 2008, LG achieved to
sell the total of more than 100 million air conditioners. Building
on its success and technological leadership in the residential air
conditioning sector, LG has moved into system air conditioning
as well.

The company produces top-notch air conditioning professionals


at its academies, of which there are nearly 80 worldwide. These
centers of excellence provide workshops and training programs
that offer valuable hands-on experience. LG also provides useful
tools for HVAC system engineers and installers, including its time
saving LG Air Conditioner Technical Solution (LATS) software.
Additionally, LG operates several state-of-the-art R&D facilities all
across the planet.

The companys range of high performance system air conditioning


products provides effective temperature control to large-scale
buildings and facilities. Overtime, LG has evolved into the total
HVAC and energy solution provider, investing in new technologies
adding chillers, VRF systems and BMS (building management
system) into its comprehensive product portfolio. Along with a
wide range of innovative solutions, LG delivers unrivalled customer
service.

One such facility is the Energy Lab, a purpose-built R&D and


testing center in northern France. Helping to keep the company
ahead of the competition, the scientists and engineers at the
Energy Lab study the effects of different environmental conditions
on LGs products. This in-depth research and analysis enables LG to
tailor its solutions to the specific environmental demands of each
individual market. Combining the best technologies with the best
ideas, LGs high quality products are now enjoyed by customers in
over 100 countries.

Control Solution & Accessories

LG HVAC CONTROL
Individual Control
Premium

Wired Remote Controller


Standard

PREMTA000
PREMTA000A
PREMTA000B

PREMTB001

Simple

PQRCVCL0QW

Centralized Control
Wireless Remote
Controller

PQWRHQ0FDB

Wi-Fi Controller*

PREMTBB01

PQRCVCL0Q

LINE-UP

LG-IR-WF-1

Centralized Control

Indoor Unit
~ 32

Indoor Unit
~ 128

Indoor Unit
~ 8,192

AC Ez

AC Smart IV

AC Manager IV

PQCSZ250S0

PACS4B000

PACM4B000

Indoor Unit
~ 64

Indoor Unit
~ 256

NEW AC Ez Touch

ACP IV

PACEZA000

Facility Integrator

PI-485

PDI

ACP BACnet

PI-485

Premium (8port)
PQNUD1S40
Standard (2port)
PPWRDB000

PQNFB17C0

For SINGLE /
MULTI / THERMA V
PMNFP14A1

ACS IO Module
(Input / Output Module)

ACP Lonworks

PEXPMB000

PLNWKB000

(Power Distribution Indicator)

Indoor Unit
Dry Contact
Control Accessory

Group Control Wire

Simple Dry Contact


PDRYCB000

For Indoor Unit

2 Points Dry Contact

PHNFP14A0

PDRYCB400

(Air-Conditioner, ERV)

(For Setback)

PZCWRCG3

Outdoor Unit

AHU Kit

IO Module

Communication Kit

Demand controller
for MULTI V IV
PVDSMN000

Return / Room Air Control


PUCKA0 (For SINGLE SPLIT)
PRCKA1
(For MULTI V)

(Input / Output Module)

Remote
Temperature Sensor

Low Ambient Kit

PQRSTA0

For MULTI V IV
PRVC2

DO Kit

KNX Gateway*

PQNFP00T0

LG-AC-KNX4
LG-AC-KNX8
LG-AC-KNX16
LG-AC-KNX64

For Indoor Unit

(Air-Conditioner, ERV)

PSNFP14A0

Dry Contact for


Thermostat
PDRYCB300

For Modbus
PDRYCB500

(For SINGLE SPLIT)

Zone Controller

Dry Contact for


Demand Control

Control kit

4 Zones by thermostat
ABZCA

Demand controller for


MULTI V III
PQDSBCDVM0

PRCKD21E (~ 4 ODUs)
PRCKD41E (~ 8 ODUs)

Variable Water Flow


Control kit

EEV Kit
(Electronic Expansion Valve)

For MULTI V WATER IV


PWFCKN000

PRLK048A0 (~ 10HP)
PRLK096A0 (~ 20HP)

PQRCHCA0Q
(Simple for Hotel)

TXV Kit
(Thermal Expansion Valve)

For MULTI V WATER II


PRVCO

Cool / Heat Selector

PRDSBM

* This product is provided by INTESIS.

Supply Air Control by DDC


PUDCA0
PRDCA0 (For MULTI V)

PACP4B000
(Digital Output Kit)

PQRCHCA0QW
(Simple for Hotel)

Other Integration Device

System Integration Device


Gateway for Protocol

PATX13A0E (8 ~ 16HP)
PATX20A0E (18 ~ 26HP)
PATX25A0E (28 ~ 36 HP)
PATX35A0E (38 ~ 46 HP)
PATX50A0E (48~56 HP)

Control Solution & Accessories

INDIVIDUAL CONTROL
12 Wireless
Remote Controller

10 Standard Wired
Remote Controller

13 Wi-Fi Controller

Indivisual
Control

08 Premium Wired
Remote Controller

CONTROL
SOLUTION

INDIVIDUAL
CONTROL

11 Simple Wired
Remote Controller

Remote Controller Line Up


Model Name

On / Off
Fan Speed Control
Temperature Setting
Mode Change
Additional Mode Setting
Auto Swing
Vane Control (Louver Direction)
E.S.P (External Static Pressure)
Reservation
Child Lock
Electric Failure Compensation
Time Display
Filter Sign
Energy Management**
Home Leave

PREMTA000
PREMTA000A
PREMTA000B

PREMTB001
PREMTBB01

PQRCVCL0QW
PQRCVCL0Q
PQRCHCA0QW
PQRCHCA0Q

PQWRHQ0FDB

LG-IR-WF-11)

Weekly / Yearly

Weekly

Sleep, On / Off
-

2 Set Points Control

*
*

* PQRCHCA0QW / PQRCHCA0Q doesnt offer this function


** Centralized control (PACS4B000 / PACP4B000 / PQNFB17C0 / PLNWKB000) and PDI (PQNUD1S40 / PPWRDB000) should be installed for this function
1) User and product registration are necessary to use functions with internet accessibility. Providing functions can be changed according to the manufacturer.

Control Solution & Accessories

CONTROL
SOLUTION

PREMIUM WIRED
REMOTE CONTROLLER
5 inch full touch screen with a premium design

PREMTA000 1)
PREMTA000A 2)
PREMTA000B 3)

Energy Management
Self Energy Management

Features 4)
- Time limit operation / Power consumption monitoring
- Weekly / Monthly / Yearly trend tracking
- Target alert alarm
- Temperature range setting

User Friendly Design

Improved Scheduling
- Timer / Daily / Weekly / Yearly / Holiday

Fan Speed Control


Temperature Setting
Mode Change
Additional Mode Setting*
Auto Swing
Vane Control (Louver Direction)
E.S.P (External Static Pressure)**
Reservation
Time Display
Electric Failure Compensation
Child Lock
Filter Sign
Energy Management
Operation Status LED
Indoor Temperature Display
Wireless Remote Controller Receiver
Display
Size (W x H x D, mm)
Black Light for Screen Saver
Home Leave

Intuitive UI & GUI Design

Display Configuration

It is more easy to use and control various


functions.

2 Set Points Control 5)

Standard Mode

- Full touch / Intuitive GUI (Graphic User Interface)


- Main display simple mode / Touch buzzer

On / Off

Premium remote controller provides


convenient trend & target graph for
different period.

* Centralized control (PACS4B000 / PACP4B000 / PQNFB17C0 / PLNWKB000) and PDI (PQNUD1S40 / PPWRDB000) should be installed for this function

Design with users Convenience

Model Name

Trend & Target Setting


Control

Users can use of five buttons as


shortcuts for frequently used
features.
Simple Mode

Enhanced Schedule Function


PREMTA000 / PREMTA000A / PREMTA000B

Function

Cooling / Heating / Auto / Dehumidification / Fan


Plasma Purification / Energy-Saving Cooling / Robot Cleaning / Heater / Humidification

Easy Pattern Schedule

Yearly / Weekly Schedule

Yearly Schedule

If you set the schedule all at once, you will be


able to effectively manage for various lengths
of time. It provides 5 kinds of reservation
functions. (Timer, Daily, Weekly, Yearly, Holiday)

It is possible to embody various


schedules as pattern setting.

Weekly Schedule Pattern

Simple / Sleep / On / Off / Weekly / Yearly / Holiday

(Remain time + Alarm)

Check Energy Usage*** / Check Operation Time / Target Setting (Energy, Operation Time) /
Time Limit Operation / Alarm Popup / Initialization Usage Data

****

5 Inch TFT color LCD (480 x 272)


137 x 121 x 16.5

2 Set Points Control

* It might not be indicated or operated at the partial product


** This function is available for certain indoor unit type
*** Centralized control (PACS4B000 / PACP4B000 / PQNFB17C0 / PLNWKB000) and PDI (PQNUD1S40 / PPWRDB000) should be installed for this function
**** For ceiling type duct
4) Indoor unit should have functions requested by the controller
5) 2 set points control works normally with MULTI V Heat Recovery and Single Heat Pump. But in case of MULTI V Heat Pump, It is not working in 2 set points control of indoor unit

* Available to save up to a maximum of 20 error histories, 20 holiday reservations and 5 daily event on week

Weekly Schedule

2 Set Points Control


2 Set Points Control
Ambient indoor temperature is guaranteed
by setting two-point temperature for
cooling and heating. New premium remote
automatically changes from heating to
cooling (and vice versa) depending on
temperature.

Home Leave
Changeable setting for occupied /
unoccupied status

Temperature

Cooling Set Point


for Home Leave
Cooling Set Point
for Occupied
Heating Set Point
for Occupied
Heating Set Point
for Home Leave

Cooling
Occupied

Home leave
(Unoccupied)

Heating
Cooling

Heating

Indoor
Temperature
Time

Arrive at a Room
Thermo-Off

Leave a Room

Indivisual
Control

1) English / Portuguese / Spanish / French


2) English / Italian / Russian / Chinese
3) English / German / Polish / Czech

Self-Management for Energy Saving

Weekly / Monthly / Yearly

After it gathers information about usage time


or electricity usage*, offer periodical history
data to users as visual information. By using
various setting mode (operation hour /
electricity usage etc.), you can manage on
your own.

Control Solution & Accessories

10

11

SIMPLE WIRED
REMOTE CONTROLLER

Standard II

Simple

Providing easy control of one or a group of indoor units with various functions

PREMTB001 (White)
PREMTBB01 (Black)

CONTROL
SOLUTION

STANDARD WIRED
REMOTE CONTROLLER

A simple way to control ofce or hotel systems in a compact design

PQRCVCL0QW (White)
PQRCVCL0Q (Black)
Indivisual
Control

Simple for Hotel

PQRCHCA0QW (White)
PQRCHCA0Q (Black)
Simple

Features1)
Model Name
On / Off
Fan Speed Control
Temperature Setting
Mode Change
Additional Mode Setting
Auto Swing
Vane Control (Louver Direction)
E.S.P (External Static Pressure)
Reservation
Time Display
Electric Failure Compensation
Child Lock
Filter Sign
Operation Status LED
Indoor Temperature Display
Wireless Remote Controller Receiver
Size (W x H x D, mm)
Blacklight
Power Consumption Monitoring
Check Model Information

Simple for Hotel

Features1)
PREMTB001 / PREMTBB01

Cooling / Heating / Auto / Dehumidification / Fan


Plasma Purification / Energy-Saving Cooling /
Robot Cleaning / Heater / Humidification

Simple / Sleep / On / Off / Weekly / Holiday

(Remain time + Alarm)

120 x 121 x 16

**

* For Ceiling Concealed Duct type


** Centralized control (PACS4B000 / PACP4B000 / PQNFB17C0 / PLNWKB000) and PDI (PQNUD1S40 / PPWRDB000) should be installed for this function
1) Indoor unit should have functions requested by the controller

Model Name
On / Off
Fan Speed Control
Temperature Setting
Mode Change
Auto Swing
Vane Control (Louver Direction)
E.S.P (External Static Pressure)
Electric Failure Compensation
Child Lock
Indoor Temperature Display
Wireless Remote Controller Receiver
Size (W x H x D, mm)
Blacklight
* For Ceiling Concealed Duct type
1) Indoor unit should have functions requested by the controller

PQRCVCL0QW / PQRCVCL0Q

PQRCHCA0QW / PQRCHCA0Q

Cooling / Heating / Auto / Dehumidification / Fan

Only Changeable by Central Controller


-

70 x 121 x 16

70 x 121 x 16

Control Solution & Accessories

12

13

WIRELESS
REMOTE CONTROLLER

WI-FI CONTROLLER

PQWRHQ0FDB

LG-IR-WF-1

Features

Models Applied

CONTROL
SOLUTION

1)

Indivisual
Control

Model Name
On / Off
Fan Speed Control
Temperature Setting
Mode Change
Additional Mode Setting
Auto Swing
Vane Control (Louver Direction)
Reservation
Indoor Temperature Display
Sleep Mode Auto
Size (W x H x D, mm)

PQWRHQ0FDB

Cooling / Heating / Auto / Dehumidification / Fan


Plasma Purification / Energy-Saving Cooling / Robot Cleaning / Auto Dry

Sleep / On / Off

Max. 7 hours
51.4 x 153 x 26

Connectable with the indoor unit having IR receiver Control and monitor
Power supply includes EU-UK-US-AU heads
Easy to install : Wall or desktop mounted
On / Off status and mode indicated by LED light
Automatic firmware Updates*
Additional internet service has to be available and registration user account in Intesis
Home cloud to use Wi-fi controller is mandatory
Intesis Home cloud app is available for android phone or iOS phone

Model Name

LG-IR-WF-1

Start / Stop Operation


Operation Mode

Cool / Heat / Auto / Fan / Dry

Set Point
Ambient Temperature
Fan Speed

* Internet access is necessary

Specifications
Model Name

LG-IR-WF-1

Enclosure

ABS (V-O, 5VB) 2,1 mm thickness PC (V-2) 1mm thickness

Dimensions (mm)

81 78 28

Weight (g)

76

Color

White

Power Supply

5VDC 0,2 A NEC Class 2 or Limited Power Source (LPS) and SELV Rated Power supply

Mounting

Wall

LED Indicators

1 Device Status

Operating Temperature

From 0oC to 40oC

Operating Humidity

<93% HR, no Condensation

Stock Humidity

<93% HR, no Condensation

RoHS Conformity

Compliant with RoHS Directive (2002 / 95 / CE)


Compliant with RoHS Directive (2002 / 95 / CE)
CE Conformity to EMC Directive (2004 /108 / EC) and Low-voltage Directive (2006 / 95 / EC)
EN 60950-1 / EN 301489-1 v1.8.1 / EN 300328

Certifications

Overview
Case 1. Connection with Indoor Units with IR Receiver
INTESIS
Home
Cloud

Wi-fi
Controller
IR

Smart
Phone

INTESIS
Home
Cloud

Wi-fi
Controller
IR

Smart
Phone
220V

220V
CAC

1) This product is provided by INTESIS.

Case 2. Connection with Duct Type Indoor Units

CAC

Control Solution & Accessories

14

CENTRALIZED CONTROL
21 ACP IV

18 AC Smart IV

22 AC Manager IV

Centralized
Control

16 AC Ez Touch

CONTROL
SOLUTION

CENTRALIZED
CONTROL

15

20 AC Ez

Central Controller Line Up


Model Name
PACEZA000

PQCSZ250S0

PACS4B000

PACP4B000

PACM4B000*

Maximum Number of Units

64

32

128

256

8,192

Individual / Group Control


(On & Off, Mode, Set Point, Fan Speed)

Web

Web

Remote Access by Client S/W

NEW

Ventilation Control
Individual Controller Lock
Error Check
Schedule
Operation History
Visual Navigation
Operation Time Limit
Temperature Limit
Web Access 1)

Web

Power Consumption Monitoring


(with PDI)

Interlock Control

Virtual Group Control

Auto Changeover / Setback

Emergency Alarm Display


ACS IO Module Interlocking

* S/W program
1) Assignment of public IP address is required to access central controller through internet.

Control Solution & Accessories

16

17

CONTROL
SOLUTION

AC EZ TOUCH
Smart management with 5 inch touch screen for small site
NEW

PACEZA000

Features

Centralized
Control

Internet

Web Access

Features
Model Name

Users can control each space efficiently through web access.


(Web access : Network configuration is locally necessary)

PACEZA000

Maximum Number of Indoor Units

64

Individual / Group Control


(On & Off, Mode, Set Point, Fan Speed)

Energy Statistics

(with PQNUD1S40 or PPWRDB000)


Statistics of operational status (time, power consumption) are
provided to help make intelligent system operation decisions.

(Temperature / Mode / Fan / All)

Individual Controller Lock


Error Check

Self diagnosis

Mode Change

Cooling / Heating / Auto / Dehumidification / Fan

Slave Mode (Interlocking with Higher Level Controller)


Schedule

Daily / Weekly / Monthly / Yearly / Exception day

Operation History
Temperature Limit
Web Access 1)
Auto Changeover / Setback
Power Consumption Monitoring (with PDI)
Emergency Alarm Display
External IO Port No.

Energy Mode

DI 1

Compatible Model

When using energy mode function, operation mode changes from


cooling to fan or heating to off mode by force.
(It is available only air conditioner and on mode indoor unit)

MULTI V / ERV / ERV DX / THERMA V / HYDRO KIT

Size (W x H x D, mm)

137 x 25 x 121

1) Assignment of public IP address is required to access central controller through internet please contact regional office to have detailed Internet connection configuration

Schedule
Schedule control allows user to set the events in advance to
maximize system performance. Also, by blocking unnecessary
operation, it prevents a waste of energy.

Installation Scene

MULTI V IV
MULTI V III
MULTI V II

Internet

MULTI V
WATER IV
MULTI V
WATER II

MULTI V S
MULTI V Mini
MULTI V SPACE II

MULTI SPLIT
SINGLE SPLIT

ERV

Appropriate PI 485 should be used according to PDB

Alarm Indicator
It works when there are some errors or its time to change the oil
or filter. Users can respond immediately according to alarm indicator
therefore HVAC system is monitored consistently.

Group / Individual Control


According to the situation, it can be controlled by group or each
indoor unit. It is useful to monitor or control for the best fit of
request.

18

Control Solution & Accessories

19

CONTROL
SOLUTION

AC SMART IV
Large 10.2 inch touch screen with intuitive GUI (Graphic User Interface) allows easy control

PACS4B000

Features

Centralized
Control

Schedule

Features
Model Name

Schedule control allows user to set the events in advance to


maximize system performance. Also, by blocking unnecessary
operation, it prevents a waste of energy.

PACS4B000

Maximum Number of Indoor Units

128

Visual Navigation
Current operation status on floor plan is checked at one view.

Individual / Group Control


(On & Off, Mode, Set Point, Fan Speed)

(Temperature / Mode / Fan / All)

Individual Controller Lock


Error Check

Self diagnosis

Mode Change

Cooling / Heating / Auto / Dehumidification / Fan

Schedule

Daily / Weekly / Monthly / Yearly / Exception day

Operation History
Visual Navigation
Operation Time Limit
Temperature Limit
Web Access 1)
Auto Changeover / Setback
Power Consumption Monitoring (with PDI)
Interlock Control
Virtual Group Control
Emergency Alarm Display
ACS IO Module Interlocking
External IO Port No.

Energy Statistics

(with PQNUD1S40 or PPWRDB000)


Statistics of operational status (time, power consumption) are
provided to help make intelligent system operation decisions.

Operation Report
Report including control status and other information is provided so
that operation history can be reviewed easily. Data can be sent by
E-mail or stored on USB or external HDD.

DI 2 / DO 2

Interfaceable Products

MULTI V / ERV / ERV DX / THERMA V / HYDRO KIT / AHU (Control Kit)

1) Assignment of public IP address is required to access central controller through internet please contact regional office to have detailed Internet connection configuration

Installation Scene
CH1
CH2

Interlocking
Allows interlocked operation of devices or between digital inputs and
outputs on the AC Smart IV.
MULTI V IV
MULTI V III
MULTI V II

Internet

MULTI V
WATER IV
MULTI V
WATER II

MULTI V S
MULTI V Mini
MULTI V SPACE II

MULTI SPLIT
SINGLE SPLIT

ERV

AHU
(Control Kit)

Appropriate PI 485 should be used according to PDB

Emergency Display
Red alert takes up the whole display upon any urgency situation and
all other control signals are blocked to prevent any possible accident.

Control Solution & Accessories

20

21

Easy to manage up to 32 indoor unit, including ERV with simple interface

ACP IV can be integrated to the web system that allows user can access the control system online
anytime, anywhere without access to PC or specific application

PQCSZ250S0

PACP4B000

Features

Features

Centralized
Control

ACP IV

CONTROL
SOLUTION

AC EZ

Model Name

PQCSZ250S0

Maximum Number of Indoor Units

32

Individual / Group Control


(On & Off, Mode, Set Point, Fan Speed)

Ventilation Control
Individual Controller Lock
Error Check
Mode Change

(Temperature / Mode / Fan / All)

Individual Controller Lock


Error Check

Self Diagnosis

Mode Change

Cooling / Heating / Auto / Dehumidification / Fan

Schedule

Daily / Weekly / Repetition / Exception day

Operation History

Operation Status, Set Temperature, Room Temperature, Schedule

Visual Navigation

190 x 120 x 17

Power

256

Individual / Group Control


(On & Off, Mode, Set Point, Fan Speed)

Cooling / Heating / Auto / Dehumidification / Fan

Size (W x H x D, mm)

PACP4B000

Maximum Number of Indoor Units

LED / LCD Display

Master / Slave Setting


Display

Model Name

Operation Time Limit

DC 12V

Temperature Limit
Web Access 1)
Auto Changeover / Setback
Power Consumption Monitoring (with PDI)
Interlock Control
Virtual Group Control
Emergency Alarm Display
ACS IO Module Interlocking
External IO Port No.

DI 10 / DO 4

Interfaceable Products

MULTI V / ERV / ERV DX / THERMA V / HYDRO KIT / AHU (Control Kit)

1) Assignment of public IP address is required to access central controller through internet.

Installation Scene

Installation Scene
CH5
CH1 ~ 4

MULTI V IV
MULTI V III
MULTI V II

MULTI V
WATER IV
MULTI V
WATER II

MULTI V S
MULTI V Mini
MULTI V SPACE II

MULTI SPLIT
SINGLE SPLIT

ERV

Appropriate PI 485 should be used according to PDB

Internet
AC Smart IV

MULTI V IV
MULTI V III
MULTI V II

MULTI V
WATER IV
MULTI V
WATER II

MULTI V S
MULTI V Mini
MULTI V SPACE II

MULTI SPLIT
SINGLE SPLIT

ERV

AHU
(Control Kit)

Appropriate PI 485 should be used according to PDB

Control Solution & Accessories

22

23

CONTROL
SOLUTION

AC MANAGER IV
Up to 32 ACP IV can be connected so that 8,192 indoor units can be controlled and monitored

PACM4B000

Solution Overview
PACP4B000

PACM4B000

PACS4B000

Features
Model Name
Maximum Number of Indoor Units
Individual / Group Control
(On & Off, Mode, Set Point, Fan Speed)
Individual Controller Lock
Error Check
Mode Change
Schedule
Operation History
Visual Navigation
Operation Time Limit
Temperature Limit
Web Access 1)
Auto Changeover / Setback
Power Consumption Monitoring (with PDI)
Interlock Control
Virtual Group Control
Emergency Alarm Display
ACS IO Module Interlocking

Centralized
Control

PDI

AC Ez

Dry Contact

PACM4B000
8,192 (supports 32 ACP IV)

ACS IO
Module

(Temperature / Mode / Fan / All)


Self diagnosis
Cooling / Heating / Auto / Dehumidification / Fan
Daily / Weekly / Repetition / Exception day

BMS System

PQNFB17C0
PLNWKB000
DO Kit

* BACnet / Lonworks G/W


can be connected to
AC Manager

Comm. Kit

Light

Pump

Fan

Etc

1) Assignment of public IP address is required to access central controller through internet.

External Device

* Combination: we recommend you to connect separated wattmeter for Indoor units and Outdoor units to have correct power distribution value
Appropriate PI 485 should be used according to PDB

Control Kit

Control Solution & Accessories

24

25

PDI

CONTROL
SOLUTION

SYSTEM
INTEGRATION DEVICE

POWER DISTRIBUTION
INDICATOR

PDI shows power consumption of up to 128 indoor units


Premium

Facility Integrator

Gateway for Protocol

PI-485

PQNUD1S40 (8 port)
Standard

ACP BACnet (Modbus)

Premium (8 port)
PQNUD1S40
Standard (2 port)
PPWRDB000

PQNFB17C0

ACS IO Module

PPWRDB000 (2 port)

For Outdoor Unit


(SINGLE / MULTI / THERMA V)
PMNFP14A1

Centralized
Control

PDI (Power Distribution Indicator)

Features
Data is backed up so that correct consumption can be checked when power outage occurred
Connector can be separated for convenient installation
Linkable with pulse type power meter

ACP Lonworks

Installation Scene

DO Kit (Digital Output Kit)

PLNWKB000

For Indoor Unit


(Air-Conditioner, ERV)
PHNFP14A0

Power Monitoring
Power In
Single Phase
50Hz / 60Hz
220V

Watt Meter
Pulse Signal

Power Cable of Indoor Unit

PEXPMB000

KNX Gateway

Power In
3 Phase 4 Wire
50Hz / 60Hz
380V
RS485
(LGAP)

PACP4B000
PQNFP00T0

LG-AC-KNX4
LG-AC-KNX8
LG-AC-KNX16
LG-AC-KNX64

For Indoor Unit


(Air-Conditioner, ERV)
PSNFP14A0

PQNFB17C0
Power Cable for 3 Phase 4 Wire
Power Cable for Single Phase
Communication Cable (2 Wire Shielded Cable)
Pulse Signal Wire
* This value could be different with measured power consumption by power meter
Combination : we recommend you to connect separated watt meter for Indoor units and Outdoor units to have correct power distribution value

or

PACS4B000

PLNWKB000

26

Control Solution & Accessories

27

DO KIT

The module can be connected with PACS4B000 or PACP4B000 if additional control points are
needed not only DI / DO but also AI / AO port. These central controller can control 3rd party device as
pump, security, lighting and so on through DI / DO and AI / AO

Connected between centralized controllers of LG and external devices,


which can switch On / Off devices such as light, pump, motor, etc

PEXPMB000

PQNFP00T0

Features

Features

CONTROL
SOLUTION

ACS IO MODULE

DIGITAL
OUTPUT KIT

Centralized
Control

Model Name

Interface Type

PEXPMB000

NTC 10k
PACS4B000
PACP4B000
PACM4B000

Linkable Products

Communication

I/O

RS-485

Digital Input

Digital Output

Universal Input

Analog Output

Number of Indoor Units


Max. I/O Points
Maximum Number of Node

Analog Input

PACS4B000

PACP4B000

64 ~ 128

128 ~ 256

8,192

130

224

1,260

16

Min.

Max.

0.68k

177k

PT 1000

803

1,573

Ni 1000

871.7

1,675.2

DC (Voltage)

0V

10V

DC (Current)

0mA

20mA

0V

10V

Analog Output

Digital Input

Binary Input
(Dry Contact)

Digital Output

Normal open

30VAC / 30VDC, 2A

When the product input is less than equal to 25A

(The device is controlled by turning On / Off the


power supply line of the product.)

1. Pull out the power or shut down the breaker.


2. Connect the power line from the breaker to the additional relay cable.
3. Connect the device power line to the additional relay cable.
4. Finish the connected area with the insulating tape.

PACM4B000

When the product input is greater than equal to 25A

* Maximum number of Indoor units may be reduced by increasing the number of I/O points.

(The device is controlled by turning On / Off the


Indoor / Outdoor communication line.)

1. Pull out the power or shut down the breaker.


2. Cut the communication line.
3. Connect the cut communication line to the additional relay cable.
4. Finish the connected area with the insulating tape.

Installation Scene
CH1 ~ 4
CH6
PACS4B000

or

PACP4B000

When the product input is greater than or equal to

25A (The device is controlled by turning On / Off the


power supply line of the product through a fieldsupplied relay)

PUMP

PACM4B000

DDC

Sensor / Valve / Actuator

Lighting

Fan

1. Pull out the power or shut down the breaker.


2. Connect the power line from the breaker to the additional relay cable.
3. Connect the field-supply relay power line to the additional relay cable.
4. Connect the device power line to the field-supply relay.
5. Finish the connected area with the insulating tape.

Alarm

Pump / Fan etc.

* D I : Digital Input, DO : Digital Output, UI : Universal Input, AO : Analog Output / Please contact our regional office to have connectable relay specification for analog output

* Please contact our regional ofce to have connectable relay specication for digital output

Control Solution & Accessories

28

29

ACP LONWORKS GATEWAY

PQNFB17C0

PLNWKB000

Centralized
Control

* Please refer PDRYCB500 for Modbus RTU

Features

Features

Process Ability
- EHP Type : 256 units (Indoor / ERV / ERV DX / Hydro Kit / THERMA V)
- AHU Control kit : Maximum 16 units

Controlling

Monitoring Items

On / Off Command

On / Off Status

Operation Mode Setting

Operation Mode Status

Fan Speed Setting

Fan Speed Status

Lock Setting

Lock Status

Air Flow Setting

Air Flow Setting

Self installation verification function using internet

(Web Server Included)


- Setting gateway
- Diagnosis of communication status on LG Air-conditioner network

Modbus TCP Protocol Support


BTL Certified (B-ASC)
It offers a variety of functions as ACP which allows the

customer to efficiently control various types of


equipment from the customers own PC.

* In case of using Modbus, the compatibility is different from BACnet. Refer to manual in detail.

Set Temperature Setting

Set Temperature Status

Current Space Temperature Status

Error Status

User Mode Setting (for only ERV)

User Mode Status (for only ERV)

Accumulator Power Distribution Status

Upper Limit Temp. Setting

Upper Limit Temperature Status

Low Limit Temp. Setting

Low Limit Temperature Status

Mode Lock Setting

Mode Lock Status

AC Operation Mode Setting


(ERV DX only)
AC On / Off Command
(ERV DX only)

Air Conditioner Operation Mode Status


(ERV DX only)
Air Conditioner On / Off Status
(ERV DX only)

Installation Scene

CH5
CH1 ~ 4

Process Ability
- EHP Type : 64 units (Indoor / ERV / Hydro Kit / THERMA V)
- AHU Control kit : Maximum 16 units

Connect to use Lonworks protocol and LG air

conditioner protocol.
Self installation verification function using internet
(Web Server Included)
- Setting gateway
- Diagnosis of communication status on LG Air-conditioner network

It offers a variety of functions as ACP which allows the

customer to efficiently control various types of


equipment from the customers own PC.

Remote Checking

BMS System
Indoor Unit : Max. 256 Units (Air Conditioner & Ventilation) / Indoor Address : 00 ~ FF

Utility Control

CH5

BMS System

CH1 ~ 4

Monitoring Items
On / Off Status
Operation Mode Setting
Fan Speed Status
Lock Status
Air Flow Setting
Set Temperature Status
Current Space Temperature Status
Error Status
Accumulator Power Distribution Status
Accumulator Power Distribution Status
Low Limit Temperature Setting
Mode Lock Status
Peak Operation Ratio Setting
Total Accumulate Power Status

Lighting
Control

Remote Checking

Utility Control

Indoor Unit : Max. 64 Units (Air Conditioner & Ventilation) / Indoor Address : 00 ~ FF

1)

1)

Internet

Internet

PACS4B000

ACP function

Controlling
On / Off Command
Operation Mode Setting
Fan Speed Setting
Lock Setting
Air Flow Setting
Set Temperature Setting
Upper Limit Temperature Setting
Low Limit Temperature Setting
Mode Lock Setting
Peak Operation Ratio Setting
All On / Off Setting
-

Installation Scene

Lighting
Control

PACS4B000
MULTI V IV
MULTI V III
MULTI V II

1) Assignment of public IP address is required to access central controller through internet.

MULTI V
WATER IV
MULTI V
WATER II

MULTI V S
MULTI V Mini
MULTI V
SPACE II

MULTI SPLIT
SINGLE SPLIT

ERV /
ERV DX

CONTROL
SOLUTION

ACP BACNET GATEWAY

AHU
(Control Kit)

Appropriate PI 485 should be used according to PDB

ACP function

MULTI V IV
MULTI V III
MULTI V II

1) Assignment of public IP address is required to access central controller through internet.

MULTI V
WATER IV
MULTI V
WATER II

MULTI V S
MULTI V Mini
MULTI V
SPACE II

MULTI SPLIT
SINGLE SPLIT

ERV

AHU
(Control Kit)

Appropriate PI 485 should be used according to PDB

Control Solution & Accessories

30

31

PI 485

Specially designed to allow monitoring and bidirectional control of all the


parameters and functionality of LG air conditioners from KNX installations

PI 485 converts the air conditioners protocol to the RS485 protocol for the central controller

LG-AC-KNX4
LG-AC-KNX8
LG-AC-KNX16
LG-AC-KNX64

PMNFP14A1
PHNFP14A0
PSNFP14A0
Centralized
Control

Easy installation, direct connection to all outdoor units (Communication interface PMNFP14A1,
when needed) and Heat recovering units (Communication interface PHNFP14A0, when needed)
throungh the RS485 Bus.
Great integration flexibility. Using the supplied software LinkBoxEIB, a complete set of communication
objects can be accessed.
Model Name
Direct connection to KNX bus
LG-AC-KNX4
Independent management of communications
LG-AC-KNX8
Power supply : 9 to 24V DC or 24V AC
LG-AC-KNX16
Standard DIN-Rail 6 modules enclosure
LG-AC-KNX64
Maximum connection unit

Features

Max. Connection Units


4
8
16

Model Name : PMNFP14A1

64

Power : Single Phase AC 220V 50/60Hz


1 for Each Outdoor Unit (Max 64 Indoor Units)

Link BoxEIB Configuration Software for IntesisBox KNX Serious

- MULTI V MINI (ARUN40GS2A / ARUV40GS2A Only needs PI485)


- SINGLE SPILIT
- MULTI SPLIT
- THERMA V

Easy to use tool for the configuration of intesisBox, in a fast and effective way.
It offers the maximum integration possibilities with a minimal knowledge required on the system to be integrated.

LinkBoxEIB
Configuration Software

- Only needed during configuration.


- One single tool for the configuration of the whole range of IntesisBox KNX series gateways.
- Supplied with IntesisBox with no additional cost.
- Configuration examples for all systems that can be integrated.
- Mapping table editable using excel, allowing a simple and fast association of KNX Group Addresses,
exported from ETS, to IntesisBoxs datapoints.
- Includes powerful and useful features for configuration, setup and troubleshooting.

Model Name : PHNFP14A0


Power : Connected with the Indoor Units
1 for Each Indoor Unit
- Indoor Unit (Air-Conditioner, ERV)

Installation Scene
Configuration
Software
LinkBoxEIB
(above 1.1.17)

(Only Needed
for Configuration)

EIB Bus

Model Name : PSNFP14A0


Power : Connected with the Indoor Units
RS232

1 for Each Indoor Unit

RS485

- Indoor Unit (Air-Conditioner, ERV)


* Provided with a case to be installed on the exterior.

IntesisBox
LG-AC-KNX4
LG-AC-KNX8
LG-AC-KNX16
LG-AC-KNX64
MULTI V IV
MULTI V III
MULTI V II
1) This product is provided by INTESIS.

CONTROL
SOLUTION

KNX GATEWAY

1)

MULTI V
MULTI V S MULTI SPLIT
WATER IV MULTI V Mini SINGLE SPLIT
MULTI V
MULTI V
WATER II
SPACE II

ERV

Appropriate PI 485 should be used according to PDB

* MULTI V PLUS II & MULTI V III & MULTI V IV series do not require any other PI 485 since these series have PI 485 in its outdoor unit PCB.

Control Solution & Accessories

32

OTHER INTEGRATION
DEVICE LINE-UP
Indoor Unit
Dry Contact

Simple Dry Contact


PDRYCB000

Dry Contact for


Thermostat
PDRYCB300

For Modbus
PDRYCB500

Outdoor Unit

AHU Kit

Group Control Wire

IO Module (Input / Output Module)

Communication Kit

PZCWRCG3

PVDSMN000

PUCKA0
PRCKA1

Remote Temperature Sensor

Low Ambient Kit

PQRSTA0

PRVC2

PUDCA0
PRDCA0

Zone Controller

Dry Contact for Demand Control

Control Kit

ABZCA

PQDSBCDVM0

PRCKD21E
PRCKD41E

Variable Water Flow Control Kit

EEV Kit (Electronic Expansion Valve)

PWFCKN000

PRLK048A0 / PRLK096A0

Control Accessory

TXV Kit (Thermal Expansion Valve)

PRVCO

Cool / Heat Selector

PRDSBM

PATX13A0E / PATX20A0E
PATX25A0E / PATX35A0E
PATX50A0E

Other
Integration Device

2 Points Dry Contact


(For Setback)
PDRYCB400

CONTROL
SOLUTION

OTHER
INTEGRATION
CONTROL

33

34

Control Solution & Accessories

35

CONTROL
SOLUTION

DRY CONTACT
Connection between an indoor unit and external devices to control various functions

PDRYCB300

Features

Features

Model Name

PDRYCB000

PDRYCB400

Model Name

Contact Point

1 Contact Point

2 Contact Point

On / Off Control

AC 220V

From Indoor Unit

Mode Control

Power Input
On / Off Control

Rotary Switch 1

Operating Set Temperature Selection

Rotary Switch 2

Operating Logic Selection

120 x 120

120 x 120

Voltage / Non Voltage Input

Error Monitoring
Operation Monitoring
Size (W x H, mm)

* Refer to each models PDB for applicable models. * Maximum operation AC : 3A


* 4th generation indoor unit has 1 contact point function for On / Off control. But in case of using more function of Dry Contact besides On / Off control, Dry Contact is needed.

PDRYCB000

PDRYCB300

(Cool, Heat, Fan)


(Low, Middle, High)

Fan Speed Setting

PDRYCB400

Other
Integration Device

PDRYCB000
PDRYCB400

Thermo Off
Error Monitoring
Operation Monitoring
Rotary Switch 1

Operating Set Temperature Selection

Rotary Switch 2

Operating Logic Selection

Size (W x H, mm)

120 x 120

PDRYCB300

AC 220V
AC 220V

To Apply Power Source


through PCB

To Apply Power Source Directly


to External Source

In Case Non Voltage Signal

In Case Voltage Signal

Installation Scene

For no Power Contact Point Signal Input

For Power Contact Point Signal Input

Indoor Unit Monitoring

Installation Scene

CN - CC
Control Module
Dry Contact
(Contact point linked
with outer part)

Key Switch

Lighting
Sensor

Fire Alarm

Timer

Motion
Detect Sensor

Door Check
Sensor

CN - CC

System Structure
* Please contact our regional office to have full compatible room controller list

36

Control Solution & Accessories

37

GROUP CONTROL WIRE

Connection between an indoor unit and external devices to control various functions

Cables used to connect a wired remote controller up to 16 indoor units

PDRYCB500

PZCWRCG3

Features

Features
Model Name

- MODBUS communicate with MODBUS master controller


- MODBUS RTU slave / 2 wire RS485 / 9,600bps
- MAX. 8 IDUs can be connected with one MODBUS master controller
- Size (W x H x D) : 120mm x 120mm x 36.5mm

Other
Integration Device

Function

CONTROL
SOLUTION

DRY CONTACT

PZCWRCG3

Y-type Cable

0.25m Length

Long Cable

9.6m Length

Memory map
Register (hexa)

Name

Range

Notes

00001

Operation

0 1

0 : Stop, 1 : Run

30003

Indoor Temperature

100 390

Degrees C x 100

30100

Error Alarm

0 1

0 : No Error, 1 : Error
0 : Cooling, 2 : Fan, 4 : Heating

40001

Set Run Mode

0 4

40002

Set Temperature

180 300

Degrees C x 100

40015

Set Fan Speed

0 3

0 : Low, 1 : Middle, 2 : High, 3 : Auto

Installation Scene

Installation Scene
<Modbus Communication Function>

Indoor 1 MAIN PCB


Indoor 1

Room
Control Master

Indoor terminal block

CN-CC

RCU*

Indoor Unit

...

Max. 8 IDUs

RED (12V)
YL (SIGNAL)
BK (GND)

Controller
* RCU : Room Control Unit.

One to one connection between


dry contact and indoor unit
CN-CC
Note :

Indoor Unit
* Please contact our regional office to have full compatible room controller list

1
2

Y type Cable assembly for connecting indoor unit and low cable.
Long Cable assembly for connecting indoor to indoor.
- Please connect cable assembly Y type Cable with already connected indoor unit.

Indoor 2
Indoor terminal block

YL (SIGNAL)
BK (GND)

Indoor 3
Indoor terminal block

YL (SIGNAL)
BK (GND)

Control Solution & Accessories

38

39

Sensor for detecting the room temperature

Controls air conditioning in up to 4 zones by external thermostat

PQRSTA0

ABZCA

Features

Features

It can help to detect the exact room temperature instead of indoor units air temperature sensor
Applied to Ceiling Mounted Cassette, Ceiling Concealed Duct, THERMA V and HYDRO KIT
Extension cable (15m) is included

Controls different zones (Up to 4 zones) by external thermostat (AC 24V)


Maintain proper air volume of each zone
Auto variation of dampers
Auto control of fan speed and On / Off operation

Indoor Unit
(Duct Type)

Zone Control
sub PCB

Installation Scene

Models Applied

1. Wire to the control box in the indoor unit by removing the existing thermistor and connect the extension cable its place.
2. Cut the extension cable to the appropriate length and connect the screw terminal of the remote sensor.

Ceiling Concealed Duct (refer to PDB for applicable models)

Wiring Diagram
Extension Cable
CN-ROOM

Ceiling Concealed Duct


1
2
3
4
5
6
7
8

CN - ZONE
Indoor Unit

AC 24V

Remote
Temperature Sensor

Wired Remote
Controller

Zone Controller

ROOM(External)
THERMOSTAT #1

Damper
Or Relay

ROOM
THERMOSTAT #2

Damper
Or Relay

ROOM
THERMOSTAT #3

Damper
Or Relay

ROOM
THERMOSTAT #4

Damper
Or Relay

ROOM1

ROOM2

Thermostat

Temperature Sensor

Temperature Sensor

Temperature Sensor

ROOM3

ROOM4

Other
Integration Device

ZONE CONTROLLER

CONTROL
SOLUTION

REMOTE
TEMPERATURE SENSOR

Control Solution & Accessories

40

INPUT / OUTPUT
MODULE

CONTROL
SOLUTION

IO MODULE

41

Interface module between system air conditioner and external device

PVDSMN000

Installation Scene
Demand Control
Provides variable setting for demand control according to input method to reduce power consumption.
This function supports 2 types of input signal : AI (0 ~ 10V, 10 Step) and contact signal (3 Step).
DDC
(Direct Digital Controller)
Capacity Control with

or

Contact Signal (3 Points / 3 Steps)

Function

MULTI V WATER IV

- Demand control
- Low noise operation
- Output outdoor or indoor unit operation status
- Output error status

MULTI V IV

IO Module

Range of Operation Rate


AI 0 ~ 10V : 0%, 40% ~ 100%
Contact signal (3 steps) : 0%, 40% ~ 80%

Description
- IO Module is communication interface module for connection
between MULTI V IV and external IO (Input / Output Module) devices.

Low Noise Operation


To reduce noise level , control outdoor units fan speed by dry contact input.

Note : IO Module is not compatible for MULTI V III

DDC
(Direct Digital Controller)

(dB) Max 7 dB*

Models Applied

Timer

or

MULTI V IV, MULTI V WATER IV, MULTI V S

Wiring

Contact Signal

1) Dry Contact Input Part


Input_1, 2, 3 : Demand control by contact input (3 Step)
Input_LNO : Low Noise Operation
Priority Setting
Using priority setting contact signal the priority of command.
(Capacity control for external command from DDC vs. peak
control by LG Central controller.)
- Close : Central controller has priority to external signal
- Open : External signal has priority to central controller (Default setting)

Noise Level

MULTI V IV

IO Module

* 8 HP model, Sound power level can be changed by outdoor unit operation status and low noise operation input signal.

Power
AC or DC
Power
AC or DC

AO_4

Error Status

AO_3
Operating Status

AO_2
AO_1

2) Analog Input Part (AI : DC 0 ~ 10V)

Output Operation and Error Status


This function displays outdoor or indoor units operation and error status.
Depends on dip switch setting, either outdoor or indoor unit operation status is reflected through output signal.
Additionally, either outside or indoor unit has an error, IO Module display error signal by another replay.

AI_1 : Demand ontrol by analog input (10 Step)


Low ambient operation (AO_1 ~ 3)
IO Module communication error display

4) Digital Output (DO : 250VAC, Max 1A)


Output error status
Output operation status

IO Module

Reserved
AI_1

Priority setting
Reserved
Input_LNO
Input_3
Input_2
Input_1

3) Analog Output Part(AO : DC 0 ~ 10V, Max 20 mA)

or

AI : Analog Input (DC0~10V)


AO : Analog Output ( DC0~10V, Max 20mA)
Input_LNO : Low Noise Operation

OFF

MULTI V WATER IV

MULTI V IV

OFF

ON

Error

Operation Status (Output 250V AC, Max 1A)


Error Status (Output 250V AC, Max 1A)

Other
Integration Device

Features

42

Control Solution & Accessories

43

PRVC2

PQDSBCDVM0

Features

Features

Function

Function

Dry contact for demand control

- 25oC Low ambient cooling operation by Low ambient kit and hood with damper
(Analog output 0 ~ 10V)
- Demand control
- Low noise operation
- Output outdoor or indoor unit operation status (250VAC, Max 1A)
- Output error status (250VAC, Max 1A)

- Demand control (3 Contact signal)


- Demand control (Co-work with DDC)
- Outdoor unit fan low speed control (Night low noise operation)
- All Off
- Error output (Display)

Error
Display

Description

Description

Low Noise

The product is especially designed for demand control.

- Low ambient kit supports -25 C cooling operation by making stable condensing
pressure with reducing air flow rate from hood and damper control given 0 ~ 10V
proportional to condensing pressure.
- Low ambient kit provides IO Module function.
- External snow hood and air damper are required for this item.*
- Transformer and terminal block are included.
o

By DDC
0 ~ 10V

Front

Back

or

By Dry
Contact

Demand Control (Input)

: Field Supply Item

* Before apply this accessory, please contact regional sales office.

Models Applied

Models Applied

MULTI V IV

MULTI V S, MULTI V III, MULTI V MINI, MULTI V SPACE II, MULTI V WATER II, MULTI V WATER S

Installation Scene

Installation Scene
Reference : Air Damper

Main PCB

DDC
(Direct Digital Controller)
0 ~ 10V (Analog Input)

Damper Actuator
(0 ~ 10V)

Contact Signal (3 Points / 3 Steps)

Transformer
220VAC
-> 24VAC

MULTI V IV

MULTI V III

IO Module

Common

DC 0 ~ 10V
Control

Note : The IO Module can control maximum three actuators. Please, review damper actuators installation manual.

24VAC

Outdoor Unit
Dry Contact

Range of Operation Rate


AI 0 ~ 10V : 0%, 40% ~ 100%
Contact Signal (3 Steps) : 0%, 40% ~ 80%

Other
Integration Device

External integration module for cooling operation with -25oC low ambient temperature.

OUTDOOR UNIT
DRY CONTACT

CONTROL
SOLUTION

LOW AMBIENT KIT

44

Control Solution & Accessories

45

COOL / HEAT SELECTOR

PWFCKN000 (MULTI V WATER IV)

PRDSBM

Cooling, heating, or fan mode can be selected


to prevent cooling and heating mixing errors during seasonal changes

Accessory developed for controlling the water flow

PRVC0 (MULTI V WATER II)

Features

Function

Indoor unit mode control without central controller


Select operation mode : Cooling, Heating, Fan mode
Mode lock for cooling & heating mixing error-proof
during the change of season

- Water pump or valve control (0 ~ 10V)


- Minimum output voltage setting available
- Operation, error output (250VAC, Max 1A)
- Dry contact input and analog output for demand control
- Digital output for operation, error status (250VAC, Max 1A)

Fan Mode
Fan Mode

Cooling
only

Cooling
only

Advantage

Mode Change
Mode Change
Heating
only
Heating
only

- Water flow consumption reduction


- Pump electricity consumption reduction
- Including IO Module (Dry contact input, Analog input / output, Digital output)
: Using Dry contact and variable water flow control function simultaneously
Cooling Tower

Wiring Diagram

Models Applied
Single Line

Cooling Tower

Water Flow Line

0 ~ 10V (Analog output)


Flow
control
valve

MULTI V IV
MULTI V S
MULTI V WATER IV
MULTI V WATER S

Pump / Cooling
Tower Controller

<Outdoor
Main PCB >
Wiring
Diagram
Flow
control
valve

MULTI V PLUS II, MULTI V PLUS


MULTI V MINI
MULTI V WATER II
MULTI V SPACE II

<Outdoor Main PCB>

Push Button
Push Button
Insert wire method

Connect Terminals (1, 2, GND) on the back side of


the outdoor dry contact to terminals (1, 2, GND) of
outdoor as show below.
Push arrow direction

Pressure
sensor

Insert wire method

From Water
Source

Push arrow direction

Inverter pump
Flow control valve : Regulates the ow or pressure of a uid, normally responding to signals generated by independent devices.
Flow Meter : Measures mass ow rate of a uid traveling through a tube. (The mass ow rate is the mass of the uid traveling past a xed point per unit time.)
Pressure Sensor : Measures the pressure.

Insert wire to connector


Shows eld wiring
Connected wiring
Shows field wiring
Connected wiring

Insert wire to connector


* Communication line length can be maximum 300m, use Communication
line as thick as 1.25mm

Other
Integration Device

Features

CONTROL
SOLUTION

VARIABLE WATER
FLOW CONTROL KIT

46

Control Solution & Accessories

47

AHU KITS

CONTROL
SOLUTION

AIR HANDLING
UNIT KITS

Solution to connect LG outdoor unit on the DX coil of an air handing unit,


with LGs high efcient products for maximum cost saving

Features
Communication Kit
PRCKA1 & PUCKA0
List

Description

Communication Kit Operation

On / Off

Mode Change

Cooling / Heating / Fan

Return Air (or Room) Temperature Setting

Communication Kit
PUDCA0
PRDCA0

PRCKD21E
PRCKD41E

EEV Kit

(Electronic Expansion Valve)


PRLK048A0
PRLK096A0

TXV Kit

(Thermal Expansion Valve)


PATX13A0E PATX25A0E
PATX20A0E PATX35A0E
PATX50A0E

Fan Speed Signal Output

3 steps fan signal output (220V)

Reservation

Other
Integration Device

PUCKA0
PRCKA1

Control Kit

Cooling 18 ~ 30oC, Heating 16 ~ 30oC

On / Off, Weekly

Return Air (or Room) Temperature Display

For MULTI V - Stand alone

Note : PRCKA1 is controlled by LG wired remote controller or LG centralized controller

Specifications

Accessories for PRCKA1 & PUCKA0


Wired Remote Controller
Standard II

Communication & Control Kit

Communication
Kit

Model

Outdoor
Unit

PRCKA1

MULTI V

PRDCA0

MULTI V

EEV Kit

TXV Kit

Description

Return / Room air control by remote controller or dry contact

280

280

135

Return / Room air or supply air (Capacity) control by DDC

330

430

180

PUCKA0

Single Split

Return / Room air or supply air (Capacity) control by DDC

280

280

135

PUDCA0

Single Split

Return / Room air or supply air (Capacity) control by DDC


This unit is connected with outdoor unit1:1

330

430

180

PRCKD21E

MULTI V

600

750

285

MULTI V

Max capacity 1 ~ 4 master outdoor unit

PRCKD41E

Max capacity 5 ~ 8 master outdoor unit

600

750

285

Control Kit

PREMTB001
(White)

Dimensions (mm)
Centralized
Controller

List

Outdoor Unit Combination


(Capacity Range)

Liquid
(ODU)

Pipe Diameter (mm)


Gas
Liquid
(ODU)
(AHU)

Dimensions (mm)
Gas
(AHU)

PDRYCB400

PDRYCB300

Modbus

IO Module
(for Outdoor Capacity Control)

PDRYCB500

PVDSMN000 (MULTI V IV)


PWFCKN000 (MULTI V WATER IV)

Type

Min

Max

Mode Change

Fan only / Heating / Cooling

Fan Step Signal Output

High / Mid / Low (3 steps)

Digital input*
(Non voltage)
Digital input
(Non voltage)
Voltage output
(220V ~ 230V)

Cooling 18 ~ 30oC, Heating 16 ~ 30oC

Analog input

0V

10V

Compressor Off, Compressor Off & Fan Off,


40 ~ 100% capacity control

Analog input

0V

10V

Room Temperature Control


Supply Air Temperature Control
(by Outdoor Capacity Control)

Monitoring

Model

PDRYCB000

Description

Communication Kit Operation

Expansion Valves
Type

PREMTBB01
(Black)

Dry Contact
Thermostat
2 point

PRDCA0 & PUDCA0

Controlling

Combination
Type

Simple

On / Off

Outdoor Unit Operation

On / Off

Communication Kit Operation

On / Off

Mode

Fan / Defrost / Cooling / Heating

PRLK048A0
EEV Kit
(Electronic
Expansion Valve) PRLK096A0

4 ~ 10HP

12.7

12.7

217

404

83

Fan Mode

High / Mid / Low (3 steps)

12 ~ 20HP

12.7

12.7

217

404

83

Error Status

No error / Error occurred

PATX13A0E

8 ~ 16HP

15.88

15.88

22.2

22.2

491

331

174

PATX20A0E
TXV Kit
(Thermal
PATX25A0E
Expansion Valve)
PATX35A0E

18 ~ 26HP

15.88

22.2

28.58

28.58

491

331

174

28 ~ 36HP

22.2

28.58

34.92

34.92

491

331

174

38 ~ 46HP

28.58

34.92

41.3

41.3

491

331

174

PATX50A0E

48 ~ 56HP

28.58

34.92

41.3

41.3

561

331

192

* Binary input and output (Open and short), DO is normal open, for more detail please refer to installation manual
Note : DDC or thermostat (filed supplied item) is required to control PRDCA0

Accessories for PRDCA0 & PUDCA0


Wired Remote Controller
Standard II (Monitoring Only)
PREMTB001
(White)

PREMTBB01
(Black)

Digital output*
(Non voltage)
Digital output
(Non voltage)
Digital output
(Non voltage)
Digital output
(Non voltage)
Digital output
(Non voltage)

Max : AC 250V, DC 30V, 1A


Max : AC 250V, DC 30V, 1A
Max : AC 250V, DC 30V, 1A
Max : AC 250V, DC 30V, 1A
Max : AC 250V, DC 30V, 1A

Control Solution & Accessories

48

AIR HANDLING
UNIT KITS

CONTROL
SOLUTION

AHU KITS

49

Solution to connect LG outdoor unit on the DX coil of an air handing unit,


with LGs high efcient products for maximum cost saving

Features

Capacity Selection

Control Kit

For Communication Kit with SINGLE SPLIT


- When selecting evaporator, change Option PCB in Communication Kit according to below table
(Basic Option PCB is for 24k Btu/h)

List

Required Item

Heating / Cooling

SA / RA temperature sensor (or SA / RA temperature & humidity sensor)

Automatic Ventilation

SA temperature, OA / RA temp&humidity sensor, Damper actuator (OA, EA, MA)

Humidification

SA temperature, RA temperature & humidity sensor, Humidifier

Inverter Fan Control

kBTU

kW

Maximum Heat
Exchanger Capacity
(kW)

Recommended Heat
Exchanger Volume
(10-3 x m3)

Air Flow Rate


(CMM)

Applicable Outdoor Units


PUCKA0
PUDCA0
Standard
H-Inverter Standard
Inverter Inverter

12

3.5

2.2

3.5

9 ~ 10

Difference pressure sensor

18

5.0

2.4

5.0

13 ~ 16.5

EBR65102903

24

7.1

2.6

7.1

14 ~ 18

EBR65102904

30

8.0

2.9

8.0

20 ~ 26.5

EBR65102905

36

10.0

3.1

10.0

26.5 ~ 32

EBR65102906

42

12.5

3.4

12.5

28 ~ 36

EBR65102907

48

14.0

4.0

14.0

30 ~ 40

EBR65102908

60

15.0

4.7

15.0

40 ~ 50

EBR77627409

70

19.0

5.2

20.0

60 ~ 70

EBR77627406

85

23.0

5.9

23.0

64 ~ 80

Smoke detection sensor

Field Supplied Item


Required Specification

Apply Location

Temperature Sensor

- Power : AC 24V, Output signal : DC 0 ~ 10V


- Temperature boundary : -50 ~ 50C

- Apply to MA, SA, RA

Temperature & Humidity Sensor

- Power : AC 24V, Output signal : DC 0 ~ 10V


- Temperature boundary : -40 ~ 70C
- Humidity boundary : 0 ~ 95% RH

- Apply to SA, RA, OA


- Can not be applied to MA

Damper Actuator

- Power : AC 24V, In/Output signal : DC 0 ~ 10V


- Torque : 15 Nm, Operation time : 150sec.
- Rotation angle : 90

- Apply to OA, EA, MA damper

Difference Pressure Sensor (for Filter)

- Power : AC 24V, Output signal : DC 0 ~ 10V


- Boundary : 0 ~ 1000Pa
* Switch type : Relay Open / Close

- Apply to filter

Static Pressure Sensor

- Power : AC 24V, Output signal : DC 0 ~ 10V


- Boundary : 0 ~ 1000pa

- Apply to SA (for inverter control)

CO2 Sensor

- Power : AC 24V, Output signal : DC 0 ~ 10V


- Boundary : 0 ~ 2000ppm

- Apply to RA duct

- Power : AC 24V, From : Contact point type

- Apply to RA duct

Note : Boundary of specification can be changed through LGAV software. However, please make a specification referring to the above table

*
*
*
-

1) Evaporator Saturated Temperature = 6oC, Air Temperature = 27oC DBT / 19oC WBT
2) Combination allowed only for air-to-air system.
* UU18W.UE4 / UU24W.U44 / UU30W.U44 Available

For Communication Kit with MULTI V


- When selecting evaporator, change Option PCB in Communication kit according to below table
(Basic Option PCB is for 36k Btu/h)
- After checking the need capacity, remove the 36k Option PCB equipped in the main PCB, and
set up the Option PCB fitted the need capacity in the main PCB.

Detail

Capacity setting
'Option PCB'

(Main PCB)

Option PCB
P/No

Capacity Index
(Btu/h)

Recommended Heat
Exchanger Volume (10-3 x m3)

Maximum Heat
Exchanger Capacity (kW)

Air Flow Rate


(CMM)

EBR52358907
EBR52358908
EBR52358909
EBR52358910
EBR52358911
EBR52358912
EBR52358914
EBR52358915
EBR52358916
EBR52358917
EBR52358913

28k
36k
42k
48k
76k
96k
115k
134k
153k
172k
192k

2.7
3.1
3.4
4.0
5.4
6.3
7.3
8.5
9.5
10.5
11.2

8.6
11.0
13.8
15.4
22.2
28.1
33.7
39.3
45.4
50.4
56.2

22 ~ 26
25 ~ 32
31 ~ 35
33 ~ 45
50 ~ 64
64 ~ 72
72 ~ 88
88 ~ 103
103 ~ 116
114 ~ 129
121 ~ 137

* Evaporator Saturated Temperature = 6oC, Air Temperature = 27oC DBT / 19oC WBT
* Heat exchanger volume (m3) : Pipe cross-section x Tube length
- Pipe cross-section (m2) = x ID2 / 4
- Tube length (m) = Tube length of 1 pipe x Tube step x Tube row

Other
Integration Device

EBR65102901

RA : Return Air, EA : Exhaust Air, OA : Outdoor Air, SA : Supply Air, MA : Mix air (RA + OA)

Smoke Detection Sensor

Outdoor Unit Capacity

EBR65102902

Smoke Detecting

List

Option PCB
12kBTU

SA / RA temperature, Static pressure sensor, Inverter driver for fan control

Filter Alarm

Capacity setting
'Option PCB'

(Main PCB)

SA / RA temperature, CO2 sensor, Damper actuator (OA, EA, MA)

Energy Saving (Cooling Mode Only)

Detail

Control Solution & Accessories

50

AIR HANDLING
UNIT KITS

CONTROL
SOLUTION

AHU KITS

51

Solution to connect LG outdoor unit on the DX coil of an air handing unit,


with LGs high efcient products for maximum cost saving

Installation Scene

Application

Simple Control with PUCKA0


SINGLE SPLIT

AHU (Field Supply)

Optional

PUCKA0

Wired Remote
Controller

Centralized
Controller

DDC (Field Supply) +


Dry Contact

Expansion Valve
is not Required

Return
Air

PUDCA0

Comm. Kit
PUCKA0

Dry Contact
(Option)

Wired Remote
Controller

*DDC

Exhaust
Air

Outdoor
Air

Supply
Air

Other
Integration Device

AHU (Field Supply)

Wired Remote
Controller

Refrigerant Piping
Communication Wire
Sensor Signal
* DDC : Digital Direct Controller

Simple Control with PUDCA0


SINGLE SPLIT

Simple Control with PUCKA0

DDC (Field Supply) +


Dry Contact

Expansion Valve
is not Required

(Monitoring Only)

Simple Control with PRCKA1


MULTI V

AHU (Field Supply)

PRCKA1

EEV Kit
or TXV Kit

Wired Remote
Controller

Centralized
Controller

DDC (Field Supply) +


Dry Contact

IO module

Simple Control with PUDCA0

Simple Control with PRDCA0


MULTI V

AHU (Field Supply)

PRDCA0

EEV Kit
or TXV Kit

Wired Remote
Controller

*DDC

DDC (Field Supply) +


Dry Contact

(Monitoring Only)

Various Control with Control Kit


MULTI V

TXV Kit Only

MULTI V

Control Kit

Centralized
Controller

TXV Kit Only

Sensors and
Actuators are
Required According
to Control Function

Comm. Kit
PUDCA0
AI (Analog Input) 0 ~ 10V
DI (Digital Input)

* DDC : Digital Direct Controller

DO (Digital Output)
Return
Air

AHU (Field Supply)

Wired Remote
Controller
(Monitoring Only)

Refrigerant Piping
Communication Wire
Sensor Signal

Exhaust
Air

Outdoor
Air

Supply
Air

Control Solution & Accessories

52

AIR HANDLING
UNIT KITS

CONTROL
SOLUTION

AHU KITS

53

Solution to connect LG outdoor unit on the DX coil of an air handing unit,


with LGs high efcient products for maximum cost saving

Application

Application

Simple Control with PRCKA1 EEV Kits + Indoor Units

Simple Control with PRDCA0 Single EEV Kit or TXV Kit

Wired Remote
Controller

Refrigerant Piping
Communication Wire
Sensor Signal

Comm. Kit
PRCKA1

Dry Contact
(Option)

* DDC : Digital Direct Controller

Refrigerant Piping
Communication Wire
Sensor Signal
*DDC

Comm. Kit
PRDCA0

Wired Remote
Controller
(Monitoring Only)

* DDC : Digital Direct Controller

AI (Analog Input) 0 ~ 10V


DI (Digital Input)
*DDC
DO (Digital Output)

Return
Air

Exhaust
Air

Outdoor
Air

Supply
Air

Exhaust
Air

Outdoor
Air

Supply
Air

EEV kit
EEV Kit
TXV Kit
or

Various Control with Control kit Multiple MULTI Vs + TXV Kits


Refrigerant Piping
Communication Wire
Thermistor (Pipe Temp.)
Signal (On / Off)
Signal (DC 0 ~ 10V)

Simple Control with PRCKA1 Single TXV Kit (without Indoor Unit)
Wired Remote
Controller

Refrigerant Piping
Communication Wire
Sensor Signal

Comm. Kit
PRCKA1

* DDC : Digital Direct Controller

Air Handling Unit

Dry Contact
(Option)

Temperature Sensor

- Return Air, Supply Air (Essential)


- Mixed Air

*DDC

Temp & Humidity Sensor

- Return Air / Supply Air / Outdoor Air

Damper Actuator
Return
Air

Exhaust
Air

Outdoor
Air

- Exhaust Air / Outdoor Air / Mixed Air

Supply
Air

Differential Pressure Switch


Valve for Humidifier
Control Kit
CO2 Sensor
TXV Kit

Smoke Detector
Fan

- Supply / Return

Wired Remote Controller


Local

Control Kit

Expansion Kit

Other
Integration Device

Return
Air

Control Solution & Accessories

54

55

Indoor
Ceiling Mounted Cassette
Cassette Cover

PTEGM0

PTDCM
PTDCQ

Cassette Panel

Plasma Kit

Easy filter cleaning with the elevation grille

Ceiling Concealed Duct

Outdoor
MULTI V

Drain Pump Kit

Air Guide

ABDPG

PBDP9

Suction Grill

PRAGX3S0
PRAGX2S0

PBSGB30
/ PBSGB40

Drain Pan

Canvas

NEW 4 Way Cassette

(Compact panel)
PT-QCHW0

PTEGM0

PTPKM0
PTPKQ0

PBSC30 / PBSC40

Ventilation Kit

CO2
Sensor

PRODX20
PRODX30
NEW PHDPA (THERMA V)

ETC.

THERMA V

Refrigerant
Leakage Detector

Solar Heating Kit

Indoor

Auto Elevation Grille

AUTO ELEVATION GRILLE


MECHANICAL
ACCESSORIES

MECHANICAL
ACCESSORIES LINE-UP

Features
Easy Filter Cleaning with Elevation Grill
- Installation inside main body
- Auto horizontal control
- 4 points support structure

- Memory for users level


- Max 4.5m length
- Model : PTEGM0 (for chassis TM, TN, TP)

4-Point Support Structure

Auto Horizontal Control

Memory for Users Level

Auto Bottom Detection

STOP

PTVK410

2 Way Cassette
PT-HLC

PTVK420 PTVK430

1 Way Cassette
(Grill Type)
PT-UUC / PT-UUC1 / PT-UTC
(Panel Type)
PT-UUD / PT-UTD

PHLLA

PRLDNVS0

PES-C0RV0

4 Way Cassette
PT-UQC / PT-UMC1

Independent Power Module

Sanitary Tank Kit

PRIP0

PHLTA / PHLTC / PHLTB

NEW

EEV Kit

NEW

IR Receiver

Domestic Hot Water Tank

Operating with wired remote controller* and wireless remote controller included in PTEGM0.
* PREMTB001, PREMTBB01

Models Applied
4 Way Cassette : Refer to PDB for applicable models

PRGK024A0

LGRTV200E
(198 LITERS)
LGRTV300E
(198 LITERS)

PWLRVN000

LGRTV200VE
(198 LITERS)
LGRTV300VE
(198 LITERS)

Inlet Grille (1EA)


Auto Elevation Grille Kit (1EA)
Wireless Remote Controller (1EA)

Mechanical Accessories Line up and Application


Type 1

INDOOR

OUTDOOR

Type 2
Auto Elevation Grille
Cassette Panel
Cassette Cover
Ventilation Kit
Plasma Kit
Suction Grille / Canvas
Drain Pump Kit
Refrigerant Leakage Detection Kit
Independent Power Module
CO2 Sensor
EEV Kit
IR Receiver
Air Guide
Drain Pan

* Only for chassis TM, TN, TP

SINGLE SPLIT

MULTI
-

MULTI V

THERMA V

Remark

4-Way Cassette
4-Way / 2-Way / 1-Way Cassette
4-Way Cassette
4-Way Cassette
4-Way Cassette
Ceiling Concealed Duct (Built-in)
Ceiling Concealed Duct
MULTI V 4th Generation Indoors
MULTI V Indoor
Energy Recovery Ventilator
MULTI V Indoors
Ceiling Concealed Duct
MULTI V Outdoor
MULTI V Outdoor / THERMA V

Parts Included
Screws (4EA)
Installation Manual (1EA)

Application

Auto elevation grille kit

Install the kit inside


indoor unit

Install the front panel


and the Inlet grille

Operate the auto elevation grille by


the wireless remote controller

Easy maintenance

56

Control Solution & Accessories

57

CASSETTE COVER / PLASMA KIT

Stylish designed panels make more unique space by various applications

Air purifying lter to prevent dust and allergens

4 Way Cassette

2 Way Cassette

PT-QCHW0

1 Way Cassette (Grill Type)

PT-HLC

PT-UUC / PT-UUC1 /
PT-UTC

Air purifying lter to repel dust and allergens

PTDCM
PTDCQ

PTPKM0
PTPKQ0

Features

Features

Features

Independent vane operation uses separate motors, making it Possible to control all four vanes independently.
The detachable corner design makes it easy to adjust the hanger during installation and to check for leakages in the drain connection pipe.

Specially designed for indoor unit


Covers the side area of cassette
Gives elegant looks
Light weight

It can remove microscopic contaminants such as dust and


pollen to help reduce allergies.

Models Applied

Models Applied

NEW

MECHANICAL
ACCESSORIES

CASSETTE PANEL

(Panel Type)

PT-UUD / PT-UTD
Indoor

PT-UQC /
PT-UMC1

Compact and Stylish Design


New 4 way cassette panel adapted unibody shape and matching with into the ceiling

* Plasma kit and Auto Elevation Grille are not applicable at the same time

Panel size is fit into the ceiling tile

Unibody
Shape

4 Way Cassette (for chassis TP, TN, TM, TQ, TR)

620m

Type

4 Way Cassette

(No Inlet Line)

2 Way Cassette
1 Way Cassette

SINGLE SPLIT

620m

Specifications
Model name

4-Way

2-Way

1-Way

Suction
Type

PT-QCHW0

Horizontal Grill

PT-UQC

Horizontal Grill

PT-UMC1

Horizontal Grill

PT-HLC

Grill

PT-UUC

Grill

PT-UUC1

Grill

PT-UTC

Grill

PT-UUD

Panel

PT-UTD

Panel

Color
(RAL)
Morning Fog
(RAL 120-4)
Morning Fog
(RAL 120-4)
Morning Fog
(RAL 120-4)
Morning Fog
(RAL 120-4)
Noble White
(RAL 110-1)
Morning Fog
(RAL 120-4)
Noble White
(RAL 110-1)
Noble White
(RAL 110-1)
Noble White
(RAL 110-1)

Dimension (mm)
W
H
D

Applied model
SINGLE SPLIT MULTI SPLIT

Gloss

Weight
(kg)

3.0

620

20

620

1.5 ~ 5.0kw

3.0

700

22

700

2.5 ~ 5.0kw

1.5 ~ 5.0kw

1.5 ~ 5.0kw

5.6

950

25

950

7.1 ~ 15.0kw

7.1kw

7.1 ~ 14.0kw

4.0

1,050

28

640

5.0 ~ 7.1kw

4.6

1,100

34

500

2.1 ~ 3.5kw

4.4

1,100

34

500

2.5 ~ 3.5kw

2.5 ~ 3.5kw

5.5

1,420

34

500

5.0 ~ 7.1kw

O
O

4.6
5.5

1,100
1,420

34
34

500
500

MULTI V

Parts Included

Parts Included

Cover A (4EA), Cover B (4EA)


Cover C (4EA), Cover D (4EA)
Screws
Installation Manual (1EA)

Plasma Kit (1EA)


Screws
Installation Manual (1EA)

Accessory Model Name


Model

Weight (kg)
NET Gross

Dimensions (mm)
W
H
D

PTDCM

PT-UMC /
PT-UMC1

TP / TN

5.9

8.8

1,157

1,157

268

TM

5.9

8.8

1,157

1,157

310

PTDCQ

TR

5.0

7.2

907

907

268

TQ

5.0

7.2

907

907

310

2.1 ~ 3.5kw
5.0 ~ 7.1kw

Front Panel

MULTI SPLIT

Option
Option
(2.5 / 3.5 / 5.0kw : PTPKQ0)
(7.1kw ~ 15.0kw : PTPKM0) (1.5 / 2.1kw : PTPKQ0)
Built-in

MULTI V
Built-in
Built-in
Built-in

58

Control Solution & Accessories

59

DRAIN PUMP KIT

Fresh air can be supplied from outside through this ventilation kit

Drains away condensed water

PTVK410
PTVK420
PTVK430

ABDPG
PBDP9

PTVK420

PTVK430

ABDPG

Indoor

PTVK410

MECHANICAL
ACCESSORIES

VENTILATION KIT

PBDP9

Features

Features

The ventilation kit can be supplied air from outside.

In some places where natural drainage is not possible, a drain pump is very useful to pump out condensed water from indoor units.
Drain pump assembly (AC 220 ~ 240V, 50 / 60Hz)

Models Applied

Models Applied

Ceiling Concealed Duct (Refer to PDB for applicable models)

There are 2 Solutions for Fresh Air


- PTVK410+PTVK420 (for chassis TP, TN, TM)
- PTVK430 (for chassis TR, TQ, TP, TN, TM)

Accessory Model Name

* Users can purchase and use PTVK430 in addition to PTVK410+PTVK420 in need to phase in larger outdoor air volume.

Ceiling Concealed Duct (Refer to PDB for applicable models)


Product

Model
12.3kg

Parts Included

SINGLE / MULTI SPLIT

PTVK410 : 1 Ventilation Kit, 8 Bolts, 1 Insulation


PTVK420 : 1 Flange, 7 Screws
PTVK420 : 1 Flange, 4 Screws, 1 Insulation

MULTI V

CB**L
Standard Inverter CM** / UM**
UB70 / UB85
Econo Inverter

Drain Pump
Included
Included
ABDPG
PBDP9
ABDPG
Included

Application
Dimensions

High head drain pump automatically drains water up to 700mm of drain-head height.
It provides perfect solution for water drainage.

Assembly Diagram

Fixture
Drain pipe

Drain Pipe Slope (1/50~1/100)

406

High Head Drain Pump


450mm

700mm

Flexible Drain Hose

840

435

443

81

13

300mm

* Included in H-Inverter
* Supplied as accessory for Standard Inverter (ABDPG/ PBDP9)

PTVK430

Parts Included
ABDPG / PBDP9

419
840
55mm

PTVK410+PTVK420

- Drain pump assembly (1EA) (AC 220 ~ 240V, 50 / 60Hz, 400CMM)


- Screw (4EA)
- Cap (1EA)
- Installation manual (1EA)

Control Solution & Accessories

60

61

SUCTION GRILLE / CANVAS


MECHANICAL
ACCESSORIES

High flexibility for a wide variety of applications

PBSGB30
PBSGB40
PBSC30
PBSC40

Parts Included
For the Suction Grille :

For the Suction canvas :

- Suction panel with air filter (1EA)


- Suction panel fix bolt M5x18 (4EA)
- Installation manual (1EA)

SUCTION GRILLE - PBSGB30 / PBSGB40

Indoor

- Air suction canvas (1EA)


- Screws for air suction canvas (4EA)
- Adjusting chain (4EA)
- Screws for adjusting chain (8EA)
- Installation manual (1EA)

CANVAS - PBSC30 / PBSC40

Dimensions

Features
High external static pressure facilitates unit use with flexible ducts of varying lengths
When using suction grille, unit requires only 270mm of ceiling space
Blends unobtrusively with any interior decoration

A
A

Models Applied

(Unit : mm)

Ceiling Concealed Duct _ Built-in type

Model Name
PBSGB30
PBSGB40

(Unit : mm)

Model Name

910
1,188

359
359

56
56

PBSC30
PBSC40

Accessory Model Name

Canvas

Capacity (Btu/h)
ARNU07GB3G2 ARNU09GB3G2 ARNU12GB3G2 ARNU15GB3G2 ARNU18GB4G2 ARNU24GB4G2

PBSGB30

PBSGB40

PBSC30

PBSC40

Application
over 270mm

Grille

Model Name

over 520mm

Category

A
B

821
1,100

274
274

42 ~ 250
42 ~ 250

Control Solution & Accessories

62

63

CO2 SENSOR
PES-C0RV0

PRLDNVS0

MECHANICAL
ACCESSORIES

CO2 sensor in ventilation system.

REFRIGERANT
LEAKAGE DETECTOR
R410A refrigerant leakage detector makes our space safer

Indoor

Features
1) Model name : PES-C0RV0
2) Specification

Features

Operation Table
CO2 Sensor Reading

Applied Model : ERV, ERV DX


Function

- Supply Vottage : DV 12V 5%


- Output : 0 ~ 5V (Linear output, 1 ~ 2,000ppm CO2)
- Accuracy : 30ppm 5% of reading

ERV Fan Operation

<500ppm

Off

500 ~ 700ppm

Low Speed

700 ~ 900ppm

High Speed

>900ppm

Super High Speed

3) Description

This detector senses refrigerant leakage and when the refrigerant concentration exceeds 6,000ppm not only it will stop indoor unit operation
but also it will give an alarm using buzzer and sensor LED. (The green and red LED lights blink simultaneously.)
Alarm is ON over 6,000ppm has been maintained 5 seconds, and on the contrary to this, Alarm is OFF under 6,000ppm has been
maintained 5 seconds.
When the alarm of the refrigerant leak detector is switched on the user must ventilate until the alarm is disabled.
The detector has to be installed inside the room and it can be installed 300 ~ 500mm from floor.

Models Applied

The product is especially designed to detect CO2 concentration in ERV system.

New 4th generation indoor units only


More detailed information refer to the MULTI V INDOOR UNIT LINE UP & FEATURES OVERVIEW. (Page 96 ~ 97)

Installation Scene

Specifications
Parts

Specifications
Rated Voltage (V)

DC 5.0 5%

Dimensions (W x H x D, mm)

31 x 44 x 20

Weight (g)
Detectable Refrigerant

Sensor

CO2 Sensor
(PES-C0RV0)

CO2 (ppm)

Standard Wired
Remote Controller

Detected Concentration (ppm)

Connecting Cable

22
R410A
0 / 6,000 Alarm Off / On

Operating Temperature Range (oC)

-10 ~ 50

Preserved Temperature Range (oC)

- 40 ~ 60

Average Power Consumption (mA)

35

Cable Length (m)

10

Dimensions of Front Plate (W x H x D, mm)

80 x 110 x 44.6

Dimension of Backplate (W x H x D, mm)

80 x 110 x 6.5

Sensor Protective Cover

2,500

Windows
Closed

Windows
Open

Windows
Closed

Windows
Open

Application
3 Stop Operation and
Ring Alarm
2 Senses Refrigerant Leakage

1,000
0 ERV with CO2 Concentration Control
Time (min)

1 Refrigerant Leakage

Control Solution & Accessories

64

65

NEW

NEW

IR RECEIVER

MULTI V EEV KIT is specially designed to reduce noise and make comfort environment

IR RECEIVER can be connected to CCD where the customer wants to control by wireless remote
controller

PRGK024A0

PWLRVN000

Features

Features
Designed for wireless control to operate Ceiling concealed duct Operation of Indication lamp (3 colors) Self-diagnosis function

Models Applied
Ceiling Cassette (up to 15kBtu)
Ceiling Concealed Duct (up to 18kBtu)
Wall Mounted (up to 24kBtu)

Console (up to 15kBtu)


Floor Standing Unit (with Case / without Case) (up to 15kBtu)
Convertible (up to 12kBtu, Ceiling Suspended Type is not able to connect this Kit)

* Fresh Air intake Unit is not able to connect this Kit

Application

Models Applied
MULTI V Indoors (Ceiling Concealed Duct, Floor Standing Units)

Application

Note : If you dont use EEV of same specification, Cooling (Heating) capacity may decrease.
Note : Do not install both the IR Receiver and Wired Remote Controller. This may cause malfunctions.

Indoor

Decreasing noise level of Multi V Indoor units Easy installation

MECHANICAL
ACCESSORIES

EEV KIT

66

Control Solution & Accessories

67

AIR GUIDE

EEV full close function in case of power cut

Air discharge in difficult to access areas

PRIP0

PRAGX*S0

MECHANICAL
ACCESSORIES

INDEPENDENT
POWER MODULE

PRAGX2S0
(14 / 16 / 18 / 20HP)

Independent Power Module is specially designed to close the Indoor EEV at power cut-Off.

Converts vertical discharge into horizontal discharge


Designed for outdoor discharge air
632

50
45

- Supply Voltage : DC 12V 50%

512

Features

Outdoor

Features

33

00

R6

512

564

PRAGX3S0
(8 / 10 / 12HP)

Direction of air discharge can be changed by simple installation


Installation flexibility
652

618

60

Models Applied
512

512

MULTI V IV (UX2, UX3)

00

50

R6

* In case of UX3, must purchase 2 units of PRAGX3SO.


632

570

652

45

50

Dimensions
618

17kg

50

832

618
564

564
33

33

60

632

632

618

50

45

904

45

760

45

832

832

832

500

832
0

718

0 60
60 R

760

760

904

45

832

50

50

500
45

652

652

900

* N : Heat Pump / B : Heat Recovery

762

* N : Heat Pump / B : Heat Recovery

832

500

Each room

570
- ARU*140LTE4
570
- ARU*160LTE4
- ARU*180LTE4
- ARU*200LTE4
900

500

904

MULTI V IV (UX3)

50

- ARU*080LTE4
- ARU*100LTE4
- ARU*120LTE4

50

1st

MULTI V IV (UX2)

900

500

A/C
Switch

Application

500

2nd

0
0 6

45

Power Plug
3rd

570

60

718

45

Main Switch

652

652

50

Independent Power Module (Option)

50

618

832

45

832

50

Each room

Switch BOX

00

00 R6

R6

50

512

512

512

R6

762

500

1st

45

A/C
Switch

500

00

2nd

652

718

900

3rd

632

MULTI V IV (UX3)

Main Switch
Power Plug

9.4kg
760

512

MULTI V IV (UX2)

50

832

33

512

12.3kg

PRAGX3S0

500

Net Weight

22.5kg

500

Gross Weight

45

50

652

Switch BOX

R6

PRAGX2S0
570

762

4th

Independent Power Module (Option)

564
00

Model Name

Outdoor Unit

1 Phase
220V

900

60

3 Phase
400V

512

MULTI V Indoors

45

Models Applied

33

652

564

Control Solution & Accessories

68

69

DRAIN PAN

SOLARS HEATING KIT


MECHANICAL
ACCESSORIES

Easy drain installation

PRODX20 / PRODX30

NEW

PHDPA (AWHP)

PHLLA

Features

This unit can be applied for outdoor units drain.

Interface for solar-thermal system with split-type THERMA V and double coil sanitary tank
Installed at the water pipe, between sanitary tank and solar-thermal system
Dimensions (H x W x D, mm) : 110 x 55 x 22
According to solar systems water temperature, THERMA V controls 3 way valves direction

Installation

Outdoor

Features

Installation Scene
Components : THERMA V system, PHLTA, PHLTC, and field-supplied items.
Outdoor

* Tuck drain pan below base pan

Service Valve

Indoor

Outdoor Unit
Indoor Unit

Drain Pipe
* In case of the installation of drain pan, drain pipe should be located below the SVC valve.
* Push drain pan in the direction of the arrow.
Brackets can be fixed on the side panel.

This unit does not cover water drops of the outside product.
Connect drain hose to drain pipe for drain condensate.
Hot Water
Solar Heating
Kit

Accessory Model Name


Model Name

Width x Length

Remark

PRODX20

920mm x 466mm

UX2

PRODX30

1,240mm x 466mm

UX3

PHDPA (AWHP)

478mm x 190mm

Solar Heat Source

Fan Coil Unit


Sanitary
Water
Tank
City Water

Floor Heating Loop

Radiator

70

Control Solution & Accessories

71

SANITARY TANK KIT

Single Coil

LGRTV200E
LGRTV300E

PHLTA (1, Spilt)


PHLTC (3, Spilt)
PHLTB (Monobloc)

Double Coil

PHRSTA0 (12m)

PHLTA (1) / PHLTC (3)

PHLTB

* The sensor (PHRSTA0) can be purchased separately in case of using other brands sanitary tank. PHRSTA0 is included in PHLTA, PHLTC, PHLTB.

Features

MECHANICAL
ACCESSORIES

DOMESTIC HOT
WATER TANK
LGRTV200VE
LGRTV300VE
Features

LGRTV200E (198 LITERS)


LGRTV300E (198 LITERS)

LGRTV200VE (198 LITERS)


LGRTV300VE (198 LITERS)

LGRTV200E

LGRTV300E

198
580
1,230
45
Stainless steel
Paint Epoxy
White NC
3
60-90
Single
LDX 2101 - Stainless Steel
80
25
25
22
22
1 / 220-240 / 50

287
580
1,680
59
Stainless steel
Paint Epoxy
White NC
3
60-90
Single
LDX 2101 - Stainless Steel
80
25
25
22
22
1 / 220-240 / 50

PHLTA

PHLTA

LGRTV200VE

LGRTV300VE

198
580
1,230
49
Stainless steel
Paint Epoxy
White NC
3
60-90
Double
LDX 2101 - Stainless Steel
80 (With an Heat Pump)
25
25
22
22
1 / 220-240 / 50

287
580
1,680
64
Stainless steel
Paint Epoxy
White NC
3
60-90
Double
LDX 2101 - Stainless Steel
80 (With an Heat Pump)
25
25
22
22
1 / 220-240 / 50

PHLTA

PHLTA

PHLTA (1) / PHLTC (3)


To control sanitary tank temperature and sanitary tank electric heater for split models.
This unit will be installed inside indoor unit.

Installation Scene

[ Monobloc ]

Domestic Hot Water Tank - Single Coil

PHLTB
Easy to install sanitary water tank for monobloc.
There is a MCCB (Mold Case Current Breaker) to protect the product.
Dimensions (H x W x D, mm) : 250 x 170 x 110
Weight (kg) : 2.1
This unit will be installed outdoor.

Domestic Hot Water Tank

General Characteristics

Characteristics of Electrical Back-up

Installation Scene

Characteristics of Exchanger
Hydraulic Connections
- Heat Pump
Hydraulic Connections
- Domestic Hot Water Tank
Electric Connection

Components : THERMA V system, PHLTA, PHLTC, and field-supplied items.


Outdoor

Outdoor

Store and provide hot water for sanitation

[ Spilt ]

Indoor

Water Volume
Diameter
Height
Empty Weight
Tank - Materials
Outer Skin - Materials
Color - White RAL
Additional Electric Heater
Adjustable Thermostat
Exchanger Type
Material Exchanger
Maximum Water Temperature
THERMA V Entry
THERMA V Exit
City Water Entry
Hot Water Exit
Suppy

L
mm
mm
kg

kW
C
C
mm
mm
mm
mm
/ V / Hz

MANDATORY OPTIONAL ACCESSORIES


Domestic Hot Water Tank Installation Kit

Outdoor Unit

Domestic Hot Water Tank - Double Coil

Indoor Unit

Domestic Hot Water Tank

General Characteristics

Characteristics of Electrical Back-up

Hot Water
Fan Coil Unit
Water Temperature
Sensor
(PHRSTA0)

Sanitary
Water
Tank
City Water

Floor Heating Loop

Radiator

Characteristics of Exchanger
Hydraulic Connections
- Heat Pump
Hydraulic Connections
- Domestic Hot Water Tank
Electric Connection

Water Volume
Diameter
Height
Empty Weight
Tank - Materials
Outer Skin - Materials
Color - White RAL
Additional Electric Heater
Adjustable Thermostat
Exchanger Type
Material Exchanger
Maximum Water Temperature
THERMA V Entry
THERMA V Exit
City Water Entry
Hot Water Exit
Suppy

L
mm
mm
kg

kW
C
C
mm
mm
mm
mm
/ V / Hz

MANDATORY OPTIONAL ACCESSORIES


Domestic Hot Water Tank Installation Kit

Control Solution & Accessories

72

73

PIPING ACCESSORIES
LINE-UP

Y BRANCH AND
HEADER BRANCH

SYNCHRO

Refrigerant distribution channel

PIPING
ACCESSORIES

2 Units

SINGLE SPLIT

MULTI SPLIT

MULTI V

ETC

Y Branch and Header Branch


(Synchro)

Branch Distributor

Heat Recovery Unit

Refrigerant Charging Kit

PMUB11A
3 Units

PMUB111A
4 Units

PMUB1111A
Liquid Pipe

Gas Pipe

PMBD3620
PMBD3630
PMBD3640

PRHR022
PRHR032
PRHR042

PRAC1

Y Branch and Branch Kit

Y Branch and Header Branch

Stopper Valve

2 Units
PMUB11A
3 Units
PMUB111A
4 Units
PMUB1111A

Features
Various Y Branch pipes of different capacities make installation easier
Y Branch and header branch for both gas and liquid are provided
Insulation material is also provided for covering the branches

Models Applied
H-inverter : 10.0 / 12.5 / 13.4kw
Standard inverter : 12.5 / 14.0 / 15.0 / 20.0 / 25.0kw
2 Units
PMBL3620
PMBL5620
2 Units
PMBL1203F0

PRVT120
PRVT780
PRVT980

Application

Drain Hose

PHDHA05T
PHDHA07T
PHDHA05B
PHDHA07B

Mechanical Accessories Line up and Application


Model name

SINGLE SPLIT

MULTI

2 Branch

3 Branch

4 Branch

Accessory Model Name

MULTI V

Remark

Y Branch and Header Branch (Synchro)

Model name
2 Units

SINGLE SPLIT

Remark

PMUB11A

50:50 (1:1)

Branch Distributor (MULTI)

MULTI F DX systems

3 Units

PMUB111A

33:33:33 (1:1:1)

Y Branch and Branch Kit (MULTI)

MULTI F DX systems

4 Units

PMUB1111A

25:25:25:25(1:1:1:1)

Heat Recovery Unit (MULTI V)

MULTI V Sync II / MULTI V III Heat Recovery / MULTI V IV Heat Recovery

Y Branch and Header Branch (MULTI V)

Various type of MULTI V Series

Type

15.88 (5/8)

19.05 (3/4)

25.4 (1)

9.52 (3/8)
12.7 (1/2)

12.7 (1/2)
15.88 (5/8)

6.35 (1/4)

9.52 (3/8)

9.52 (3/8)

12.7 (1/2)

74

Control Solution & Accessories

75

BRANCH DISTRIBUTOR

DISTRIBUTOR
BOX

Effective way of distributing refrigerant

Y BRANCH AND
BRANCH KIT MULTI F DX
Refrigerant distribution channel

PIPING
ACCESSORIES

2 Units

PMBL3620
PMBL5620

PMBD3620
PMBD3630
PMBD3640

2 Units

PMBL1203F0
PMBD3620

PMBD3630

PMBD3640

Features
Distribution of refrigerant to various indoor units
3 models (2, 3, 4 Indoor units)
Consists of LEVs inside it
Controlling PCB inside the unit

Internally insulated (Prevents any chances of drainage)


Flare joints for easy and clean installation
Compact design (Low height)
Flexible installation

Features

Models Applied

Y Branch and Branch kit make Multi F DX installation easier


Y Branch and Branch kit for both gas and liquid are provided
Insulation material is also provided for covering the branches

MULTI F DX systems (refer to PDB for applicable models)

Application

Models Applied
MULTI F DX systems (Refer to PDB for applicable models)

Parts Included
BD (Banch Distributor) unit (1EA)
Brackets (4EA)
Screws (8EA)
Installation Manual (1EA)

Parts Included
Y Branch for gas side and liquid side (1set)
Installation manual (1EA)

Specifications
Model name
Connectable Indoor Units
Capacity
Casing Colour
Power Source
Power Consumption
Running Current
Dimensions
Packing Dimensions
Net Weight
Connecting Cable
Piping Connection
(Outdoor Unit)
Piping Connection
(Indoor Unit)
Parts

PMBD3620
Number of Indoor Units
(Btu/hr)
/ V / Hz
(W)
(A)
(W x H x D)
(W x H x D)

(mm)
(mm)

Indoor Unit No. x mm


Outdoor Unit No. x mm
liquid
(mm)
Gas
(mm)
Liquid
(mm)
Gas
(mm)
Hanger
(EA)
Screw
(EA)
Manual
(EA)

1~2
5k / 7k / 9k / 12k / 18k / 24k
Paintingless
1 / 220-240 / 50
10
0.05
302 x 143 x 252
422 x 202 x 300
4.8
4 x 0.75
4 x 0.75
9.52
19.05
6.35 x 2
9.52 x 2
4
8
1

PMBD3630

PMBD3640

1~3
5k / 7k / 9k / 12k / 18k / 24k
Paintingless
1 / 200-240 / 50
10
0.05
302 x 143 x 252
422 x 202 x 300
4.9
4 x 0.75
4 x 0.75
9.52
19.05
6.35 x 3
9.52 x 3
4
8
1

1~4
5k / 7k/9k / 12k / 18k / 24k
Paintingless
1 / 200-240 / 50
10
0.05
302 x 143 x 252
422 x 202 x 300
5.0
4 x 0.75
4 x 0.75
9.52
19.05
6.35 x 4
9.52 x 4
4
8
1

Accessory Model Name


(Unit : mm)

No. of Branch
Distribution Units

Applicable Model

PMBL3620

2 units

Only 3, 36k Btu/h

PMBL5620

2 units

1, 3

Model Name

Specifications
Gas

Liquid
6.35
6.35

6.35
6.35

15.88
15.88

15.88
15.88

6.35
6.35

15.88
15.88

15.88
15.88

15.88
15.88

6.35
6.35

11 .. 55

.. 55
1115.88

15.88

.5
.5

6.35
6.35
6.35
.5

.56.35
.5
.5

11 .. 55

PMBL1203F0

3 units

1, 3

1 1. 5. 5

1 1. 5. 5
19.05

19.05

1 1. 5. 5

9.52

.5 .5
9.52

9.52

.5 .5
9.52

.5 .5

Control Solution & Accessories

76

77

HEAT RECOVERY UNIT


(Unit : mm)

Model Name

PRHR022
(2 Branch Unit)

PRHR032
(3 Branch Unit)

PRHR042
(4 Branch Unit)

Liquid

High pressure

Low pressure

Indoor Unit Reducer

Features
Max. 32 indoor units can be connected (Max. 8 indoor units per branch)
It is easy to install due to the automatic search algorithm for piping detection
Subcooling cycle in HR unit makes the system efficiency maximum

PRHR022

HR Unit Reducer

Models Applied
MULTI V IV Heat Recovery
MULTI V III Heat Recovery
MULTI V SYNC II
MULTI V SYNC

PRHR032 /
PRHR042

MULTI V WATER IV Heat Recovery


MULTI V WATER II Heat Recovery

Convenient Free Zoning

Specifications

MULTI V IV Heat recovery provides flexible control over individual zones for the users convenience.

Model name

PRHR032

PRHR042

Number of Branch

EA

Maximum Connectable Capacity of Indoor Units (Per branch / unit)

kW

16 / 32

16 / 48

16 / 58

Maximum Number of Connectable Indoor units per Branch

EA

kW

0.026

0.040

0.040
0.040

Nominal Input

PRHR022

Cooling

kW

0.026

0.040

Net. Weight

Heating

kg

18

20

22

Dimensions (W x H x D)

mm

801 x 218 x 617

801 x 218 x 617

801 x 218 x 617

Indoor Unit
Piping
connections

Outdoor Unit

Liquid

mm (inch)

9.52 (3/8)

9.52 (3/8)

9.52 (3/8)

Gas

mm (inch)

15.88 (5/8)

422 x 202 x 300

422 x 202 x 300

Liquid

mm (inch)

9.52 (3/8)

15.88 (5/8)

15.88 (5/8)

Low pressure

mm (inch)

22.2 (7/8)

28.58 (11/8)

28.58 (11/8)

High Pressure
Power supply

mm (inch)

19.05 (3/4)

22.2 (7/8)

22.2 (7/8)

/ V / Hz

1 / 220~240 / 50

1 / 220~240 / 50

1 / 220~240 / 50

Individual Control

Office

- Perfect individual control over spaces ventilation needed

Zone Control
- Max. of 8 indoor units can be connected for one branch
- Max. of 32 indoor units can be connected for one HR unit
- Same opeational model can be operated by indoor units
with zone control function installed

Combination of Individual and Zoning Installations


- Flexible piping design

Save Product and Installation Cost


Room

[Zoning Control]

IT Room
HR Unit

Parts Included
HR unit (1EA)
Hanging bolts M10 or M8 (4EA)
Nut M8 or M10 (8EA)

Zoning Control (Max Indoor Unit 8EA)


Washers M10 (8EA)
Reducers

Kitchen

PIPING
ACCESSORIES

Reducers for Indoor Unit and HR Unit

PRHR022
PRHR032
PRHR042

Control Solution & Accessories

78

79

Y BRANCH AND
HEADER BRANCH (

For refrigerant distribution of indoor units

PIPING
ACCESSORIES

Details of Model Name


[Header Branch]
R410A
(Unit : mm)

Model Name

Y Branch

Header Branch
4 Branch /
ARBL054

Features
Various Y Branch pipe of different capacities make MULTI V installation much easier.
Y Branch and header branch for both gas and liquid are provided.
Insulation material is also provided for covering the branches.

7 Branch /
ARBL057

Piping Diagram
Heat Pump System
Y Branch for
Indoor Units (2 Pipes)

Header for
Indoor Units (2 Pipes)

4 Branch /
ARBL104

Y Branch for Heat Pump


Outdoor Units (2 Pipes)

7 Branch /
ARBL107

Heat Recovery System


Y Branch for
Heat Recovery Units (3 Pipes)
HR Unit

10 Branch /
ARBL1010

Y Branch for Heat Recovery


Outdoor Units (3 Pipes)
Y Branch for
Zoning Control (2 Pipes)
HR Unit

10 Branch /
ARBL2010

Models Applied
MULTI V IV
MULTI V S
MULTI V WATER IV
MULTI V WATER S

MULTI V III, MULTI V PLUS II, MULTI V PLUS


MULTI V MINI
MULTI V WATER II
MULTI V SPACE II

Gas Pipe

Liquid Pipe

80

Control Solution & Accessories

81

PIPING ACCESSORIES
Y Branch pipe for connection of outdoor units
PIPING
ACCESSORIES

[Heat Pump]
R410A MULTI V IV, MULTI V III, MULTI V WATER IV, MULTI V WATER II

[Heat Recovery]
R410A MULTI V IV Heat Recovery, MULTI V III Heat Recovery, MULTI V WATER IV Heat Recovery,
MULTI V WATER II Heat Recovery
(Unit : mm)

(Unit : mm)

2 Outdoor Units
Model Name

Low Pressure Gas Pipe

Liquid Pipe

416
408
I.D.28.58

I.D.28.58

C
ARCNN21

ARCNN21

C
ARCNN21

111

I.D.22.2

I.D.31.8 I.D.34.9

416
408
I.D.15.88

I.D.28.58

130

BARCNN21
C

Model Name

416
408
I.D.28.58
I.D.41.3
I.D.41.3
I.D.31.8 I.D.34.9

B
ARCNN31
C
ARCNN21

416
408
I.D.15.88

I.D.28.58
I.D.34.9

O.D.34.9

111

111

I.D.22.2

415 70
130375

C
ARCNN31

341

298

I.D.41.3

416
408

I.D.41.3
I.D.28.58

I.D.41.3
I.D.31.8 I.D.34.9

134

I.D.34.9

111

I.D.28.58
I.D.28.58

O.D.34.9

111

I.D.22.2
I.D.28.58

125

A
ARCNN41
B
ARCNN31
C
ARCNN21

341

I.D.44.48 I.D.53.98

I.D.28.58

B C
ARCNN31

Model Name

I.D.41.3

298

I.D.41.3

134

I.D.28.58
I.D.34.9

O.D.34.9 Gas Pipe


LowI.D.41.3
Pressure

I.D.44.48 I.D.53.98

111

I.D.12.7

I.D.19.05

I.D.9.52

83
I.D.22.2

.D.38.1 O.D.34.9

I.D.22.2

I.D.28.58

I.D.15.88

I.D.15.88
I.D.19.05

83

I.D.19.05

I.D.19.05

O.D.19.05
I.D.12.7

I.D.15.88
I.D.15.88

70

I.D.12.7

83

I.D.15.88 I.D.12.7

I.D.15.88

I.D.12.7
Liquid Pipe

I.D.22.2 O.D.19.05

Model Name

I.D.15.88

Low Pressure Gas Pipe

281

70

High Pressure Gas Pipe

281

341
298

111
I.D.22.2
I.D.12.7 I.D.9.52
83
I.D.15.88 I.D.12.7
I.D.28.58

I.D.15.88 I.D.12.7
I.D.15.88
83
I.D.19.05

ARCNB31

I.D.34.9

I.D.41.3
I.D.41.3

I.D.15.88

I.D.12.7

I.D.28.58

111
I.D.22.2

O.D.34.9

83

416
408

334
281

83

I.D.19.05

I.D.19.05

83

I.D.31.8

I.D.28.58

111

I.D.22.2

I.D.34.9
I.D.41.31 .D.38.1

I.D.28.58

I.D.15.88 I.D.12.7
I.D.22.2 O.D.19.05

I.D.28.58
I.D.12.7

I.D.19.05

I.D.12.7 I.D.9.52

I.D.19.05

O.D.34. 9
I.D.28.58

I.D.15.88 I.D.12.7

125

130

I.D.15.88

334

281

70

70

I.D.22.2
334
I.D.41.3
I.D.44.48 I.D.53.98 I.D.25.4 O.D.22.2
281

80
4I.D.41.3
Outdoor
Units
I.D.22.2 I.D.19.05

2 Outdoor Units
Liquid Pipe

334

341
I.D.19.05
298

I.D.41.3

83

I.D.12.7 I.D.9.52

I.D.19.05

I.D.19.05

83
I.D.22.2

134

281

334

I.D.19.05

281

I.D.34.9
I.D.28.58

I.D.19.05

83

I.D.25.4 O.D.22.2
111
83

I.D.19.05

I.D.15.88 I.D.12.7
I.D.22.2

I.D.19.05
80

83

I.D.19.05

Liquid Pipe

O.D.34.9
I.D.28.58
I.D.15.88 I.D.12.7

Model Name

Low Pressure Gas Pipe

4 Outdoor Units
Liquid Pipe

High Pressure Gas Pipe

I.D.15.88 I.D.12.7

125
415

415

A
ARCNN41

83

I.D.15.88
I.D.19.05

334

I.D.28.58

375

I.D.41.31
I.D.12.7

I.D.22.22

I.D.31.8 I.D.34.9

334
281

I.D.15.88

331
314
83 I.D.22.2

I.D.15.88 I.D.12.7
111

125

ARCNN41

I.D.12.7
I.D.28.58

334
415
130
375

A
ARCNN41
B
ARCNN31

341

ARCNB21

334

I.D.41.3
O.D.34.9
I.D.19.05
I.D.31.8 I.D.34.9

130

I.D.44.48 I.D.53.98

281

I.D.15.88
I.D.28.58
I.D.34.9
111
I.D.19.05
I.D.12.7 I.D.9.52
111
I.D.22.2

334
I.D.19.05
83 I.D.22.2 I.D.19.05
298
I.D.22.2 I.D.19.05
281
134
I.D.41.3
I.D.44.48 I.D.53.98
281
I.D.25.4 O.D.22.2
I.D.25.4 O.D.22.2
331
416
331
314
408
I.D.12.7
I.D.15.88
314
I.D.15.88
I.D.28.58 111
I.D.28.58
I.D.41.3
I.D.34.9
83
I.D.22.2 I.D.15.88
I.D.19.05
I.D.19.05
I.D.28.58 I.D.15.88
I.D.22.2
I.D.19.05
80
80

375

A
ARCNN41

334

281
331
314

I.D.41.3 I.D.38.1
125 O.D.34.9
I.D.22.2
O.D.19.05

I.D.41.3 I.D.38.1 O.D.34.9

415

83

130

334

I.D.41.3 I.D.38.1
O.D.34.9
125

I.D.28.58

415
130
375

I.D.28.58
I.D.41.3
I.D.22.2 I.D.19.05
I.D.19.05
I.D.41.3
O.D.34.9
I.D.31.8 I.D.34.9

Low Pressure Gas Pipe

A
ARCNN41
B
B
C
ARCNN31
C
B
C
ARCNN21

331
314
I.D.18.88

I.D.28.58

70

3 Outdoor I.D.22.2
UnitsO.D.19.05I.D.28.58 I.D.15.88 I.D.12.7

I.D.28.58

I.D.41.3 I.D.38.1 O.D.34.9


125

I.D.22.2 O.D.19.05

70

298

298

B
ARCNN31
C

I.D.12.7 I.D.9.52

I.D.19.05

I.D.15.88

I.D.28.58

I.D.15.88

High Pressure Gas Pipe

341

341

I.D.12.7
I.D.28.58

83

2 Outdoor Units
Liquid Pipe

Low Pressure Gas Pipe


416
408

331
314
I.D.15.88

I.D.15.88

I.D.12.7 111
I.D.9.52
I.D.22.2

I.D.19.05
I.D.31.8 I.D.34.9

130

331
314
I.D.28.58

I.D.41.3 I.D.38.1
O.D.34.9
I.D.22.2
O.D.19.05

I.D.41.3 I.D.38.1 O.D.34.9

I.D.28.58

Model Name

A
ARCNN41
I.D.41.3

I.D.28.58

134

281

281

I.D.53.98I.D.19.05
I.D.44.48I.D.22.2

I.D.41.3

I.D.19.05
134

83

I.D.19.05

I.D.19.05

83

I.D.25.4 O.D.22.2

I.D.25.4 O.D.22.2
I.D.15.88 I.D.12.7
I.D.28.58
80

I.D.22.2

ARCNB41

I.D.44.48 I.D.53.98

I.D.41.3

134

I.D.22.2

I.D.19.05
I.D.25.4

I.D.19.05
O.D.22. 2

83

I.D.41.3

I.D.34.9
I.D.41.3

O.D.34. 9

I.D.15.88 I.D.12.7

I.D.15.88 I.D.12.7
80

341
298

334
281

415
375

334

334

375

I.D.28.58

80

I.D.28.58
125

111

Control Solution & Accessories

82

83

PIPING ACCESSORIES
Y Branch pipe for connection of outdoor units
PIPING
ACCESSORIES

[Heat Pump, Heat Recovery Zone Control]


R410A MULTI V IV, MULTI V III, MULTI V PLUS II, MULTI V PLUS, MULTI V S, MULTI V MINI,
MULTI V SPACE II, MULTI V WATER IV, MULTI V WATER S, MULTI V WATER II

[Heat Recovery]
R410A MULTI V IV Heat Recovery, MULTI V III Heat Recovery, MULTI V WATER IV Heat Recovery,
MULTI V WATER II Heat Recovery
(Unit : mm)

(Unit : mm)

Model Name

Gas Pipe

Liquid Pipe
I.D15.88

I.D15.88

I.D12.7

Model Name

I.D9.52

I.D9.52

Low Pressure Gas Pipe

High Pressure Gas Pipe

I.D6.35
I.D15.88

I.D12.7

ARBLN01621

Liquid Pipe
I.D9.52

I.D9.52

I.D6.35

I.D6.35

I.D15.88

ARBLB01621
I.D12.7

I.D19.05

I.D15.88

I.D12.7

O.D15.88

I.D6.35

I.D15.88

I.D6.35

I.D. 9.52
O.D9.52

I.D12.7

I.D19.05

I.D15.88

I.D12.7

O.D15.88
I.D22.2

I.D19.05

I.D19.05

I.D15.88

I.D9.52

I.D9.52

I.D6.35

I.D12.7

I.D25.4

I.D22.2

ARBLN03321

I.D28.58

I.D9.52

I.D9.52

I.D9.52

I.D6.35

ARBLB03321

I.D12.7

I.D 22.2

I.D6.35

I.D12.7

I.D25.4

O.D19.05

I.D25.4

I.D19.05

I.D15.88

I.D12.7

I.D15.88
I.D19.05

O.D19.05
I.D 22.2

I.D19.05

I.D12.7

I.D12.7

O.D19.05

I.D6.35

I.D. 9.52
O.D9.52

I.D12.7

I.D12.7

O.D19.05

I.D28.58

I.D12.7

I.D15.88
I.D19.05

I.D9.52
I.D 22.2

I.D 22.2

R410A MULTI V IV, MULTI V III, MULTI V PLUS II, MULTI V PLUS, MULTI V S, MULTI V MINI,
MULTI V SPACE II, MULTI V WATER IV, MULTI V WATER S, MULTI V WATER II
Gas Pipe

I.D22.2

I.D15.88

I.D28.58

I.D22.2

I.D15.88

I.D12.7

I.D15.88

ARBLN07121

I.D28.58

I.D34.9

I.D15.88

I.D19.05

O.D19.05

O.D31.8

I.D28.58

I.D22.2

I.D15.88
O.D12.7 I.D6.35
I.D9.52

O.D12.7

I.D34.9

I.D19.05

I.D41.3

I.D34.9

I.D38.1

I.D28.58

I.D9.52
O.D12.7

I.D28.58

I.D38.1

ARBLB14521

I.D34.9
I.D41.3

I.D38.1

I.D41.3 O.D34.9
I.D41.3
O.D38.1
I.D38.1

O.D22.2 I.D15.88
I.D19.05

I.D28.58

I.D41.3
O.D38.1

I.D41.3

I.D22.2

I.D34.9

O.D34.9

I.D38.1

I.D28.58

I.D38.1
I.D34.9

I.D15.88
O.D22.2
I.D19.05

I.D22.2

I.D12.7
O.D15.88

O.D28.58

I.D19.05

I.D22.2

I.D12.7
O.D28.58 I.D19.05
O.D15.88
I.D22.2

R410A MULTI V IV Heat Recovery, MULTI V III Heat Recovery, MULTI V WATER IV Heat Recovery,
MULTI V WATER II Heat Recovery

R410A MULTI V IV, MULTI V III, MULTI V PLUS II, MULTI V PLUS, MULTI V S, MULTI V MINI,
MULTI V SPACE II, MULTI V WATER IV, MULTI V WATER S, MULTI V WATER II

(Unit : mm)

Model Name

Low Pressure Gas Pipe

(Unit : mm)

Model Name

Low Pressure Gas pipe

I.D.53.98

Liquid pipe

I.D.44.48

I.D.34.9

I.D.28.58
X2
175

O.D.44.48

I.D.53.98

2
3
100

I.D.22.2

3
O.D.22. 2

346
379

I.D.15.88

O.D.19.05

I.D.15.88

2 3

I.D19.05
O.D22.2
3

I.D6.35

O.D12.7

471
517

96

I.D.12.7

I.D28.58
2

I.D15.88 O.D38.1 I.D41.3

120
3
O.D15.88

O.D34.9

I.D41.3
130

O.D28.58

I.D22.2
I.D19.05

2
70

I.D38.1

3
90

I.D12.7

125

3
110

I.D28.58
I.D34.9
I.D22.2

I.D38.1

I.D19.52
X2

110
120

I.D38.1

I.D.19.05
2

I.D.22.2

115
I.D.19.05

3
70

I.D22.2

I.D.25.4
I.D.22.2
I.D.19.05

I.D.25.4
O.D.28.58
X2 3

I.D12.7
O.D15.88

I.D25.4

I.D31.8

I.D34.9
I.D.41.3

I.D.25.4

I.D.44.48
I.D38.1 134

I.D41.3

O.D.38.1
2
3

High Pressure Gas Pipe


I.D34.9

ARBLB23220

Liquid Pipe

I.D.44.48
I.D41.3
I.D38.1

420
490

ARBLN23220

I.D19.05

I.D9.52

I.D12.7

I.D15.88

I.D31.8 O.D22.2
I.D28.58 O.D19.05 I.D28.58
I.D34.9
O.D31.8
I.D22.2

ARBLN14521

I.D15.88
I.D6.35
O.D12.7
I.D9.52

O.D22.2

I.D31.8

I.D12.7

I.D12.7

I.D19.05

I.D31.8

I.D34.9

I.D12.7

I.D19.05
I.D19.05

I.D15.88

I.D15.88

I.D12.7

I.D19.05

I.D12.7

I.D15.88

I.D12.7

I.D31.8

ARBLB07121

Liquid Pipe
I.D19.05

I.D19.05

I.D19.05
I.D28.58

(Unit : mm)

Model Name

I.D6.35
I.D12.7

O.D19.05

I.D25.4

O.D19.05

120

Control Solution & Accessories

84

85

REFRIGERANT
CHARGING KIT

STOPPER VALVES

Recharging refrigerant after a pump down or when refrigerant is either insufficient or excessive
PIPING
ACCESSORIES

Under 1 / 2 (inch)

PRVT120

PRAC1

Under 7 / 8 (inch)

PRVT780
Under 9 / 8 (inch)

PRVT980
Features

Features

Arrange manifold, capillary assembly, refrigerant vessel and scale


Connect manifold to the gas pipe service valve of outdoor uint as shown in the figure
Connect manifold and capillary tube. Use designated capillary assembly only If designated capillary assembly isnt used,
the system may get damaged
Connect capillary and refrigerant vessel
Purge hose and manifold
After 568 is displayed, open the valve and charge the refrigerant

Model Name

Specification

PRVT120

PRVT780

Models Applied
MULTI V III Heat Pump
MULTI V III Heat Recovery
MULTI V PLUS II
MULTI V SYNC II

Mainfold
PRVT980

Capillary Assembly

Usage
This unit can be applied for the additional indoor units installation.
This unit can be applied for each indoor units service.

* Fault Detect & Diagnosis

Refrigerant

Installation

Pin(Closed)

1. Cut the inlet side of the connector,


and weld the pipe

2. If installing additional indoor units,


the outlet side connector should be
cut according to installation pipe.

* When welding, service valve shoud be wrapped by wet cloth.

3. When installing a stopper valve, the


flare part should be facing towards
additional indoor unit.

Pin(Open)

4. When installing anadditional indoor


unit, the SVC valve should be in
closed state.

Control Solution & Accessories

86

87

STOPPER VALVES

DRAIN HOSE
Easy drain installation

Case1
In case of the installation of additional
Cut inlet side of the connector, and weld
pipe 1 & 2 : Need to install indoor units)
indoor unit, outlet side connector should
(Room 3 & 4 : In use /the
Room
be cut according to installation pipe.

* Stopper Valve is already installed

PIPING
ACCESSORIES

Details of Model Name

PHDHA05T
PHDHA07T
PHDHA05B
PHDHA07B

"A"
9.52 : 19.05
Room 1

3.0m
9.52 : 19.05
3.0m

Closed
State
Pin(Closed)

Pin(Open)

Stopper Valves

In case of installation of stopper valve,


9.52 : 15.88In case of installation of additional
flare part should be facing towards
indoor unit, SVC valve should be in
10.0m
additional indoor unit.
closed state

Room 2

-When welding, service valve shoud be wrapped by wet cloth.


9.52 : 15.88

5.0m
6.35 : 12.7
3.0m

Features
It reduces the installation time by over 40% with elbow-less drain hose.
Midget drain pump covers maximum 800mm high, featuring easy piping installation.

Models Applied

Room 3

Ceiling Mounted Cassette


and Ceiling Concealed Duct
(refer to PDB for applicable model)

Room 4

Max. 450

In case of installation of additional indoor unit, refrigerant of used indoor unit must be discharged. (Room 3 & Room 4)
If stopper valve is already installed, you can install additional indoor unit without refrigerant loss from the entire system.
After installation of additional indoor unit, you just need refrigerant charging for A section.
In case of the installation of additional
Cut inlet side of the connector, and weld
Then, open the Stopper Valve.
the pipe
indoor unit, outlet side connector should

250

Ceiling Mounted Cassette (4 Way, 1 Way)


Ceiling Concealed Duct
(with Drain Pump)

Flexible Hose
Make a Loop Form
(Unit : mm)

be cut according to installation pipe.

Open / Close Port

Charge Port

Accessory Model Name

9.52 : 19.05
3.0m
9.52 : 19.05
3.0m

Pin(Closed)

Stopper Valves

: 15.88
In case of installation of9.52
stopper
valve,
flare part should be facing towards
additional indoor unit.
10.0m

In case of installation of additional


indoor unit, SVC valve should be in
closed state

6.35 : 12.7
3.0m
-When welding, service valve shoud be wrapped by wet cloth.
9.52 : 15.88
3.0m

Room 3

Room 4

Pin(Open)
Open
State

Room 2

Room 1

Model Name

Length

Quantity

PHDHA05T

500mm

30EA

PHDHA07T

700mm

30EA

PHDHA05B

500mm

5EA

PHDHA07B

700mm

5EA

88

Control Solution & Accessories

89

COMPATIBILITY TABLE

PREMTA000
PREMTA000A
PREMTA000B

Standard ll

PREMTBB01

PREMTB001

PQRCVCLOQ

PQRCVC0QW

ARNU-C4
Ceiling
Mounted
Cassette

Simple

4 Way

Simple
for Hotel

PQRCHCA0Q PQRCHCA0QW PQWRHQ0FDB

ARNU-C4

ARNU-A4

2 Way / 1 Way

Dry Contact

Wireless

ARNU-A4
High Statics
Mid Statics
Low Statics

ARNU-G4

ARNU-G4
Built-in

MULTI V

FAU
(Fresh Air
intake Unit)

ARNU-Z4

Convertible
& Ceiling
Suspended
Unit

ARNU-A2

Console

ARNU-A4

Floor
Standing
Unit

ARNU-A4
ARNU-U4
ARNU-A4
ARNU-*4 1)

Wall
Mounted
Unit

Simple Dry
Contact
PDRYCB000

2 points Dry
Contact
PDRYCB400

Dry Contact for


Thermostat
PDRYCB300

For Modbus
PDRYCB500

LG-IR-WF-1

ARNU-L4
ARNU-A4

HYDRO KIT 2)

Ventilation

Energy
Recovery
Ventilator
Energy Recovery
Ventilator with
DX coil

AHU Communication Kit


1) Artcool Mirror : Mirror (R) / Silver (V) / White (W)
2) It has a separate remote controller

: Wired remote controller is required

x
x

X : Compatibility is unavailable
Controller

Wi-Fi

High Sensible

Ceiling
Concealed
Duct

: Compatibility is available

Model
Product
Ceiling Mounted
Cassette
Ceiling
H-Inverter Concealed Duct
Ceiling
Suspended Unit
Ceiling Mounted
Cassette
High

SINGLE SPLIT

Product

Premium

: Compatibility is available but more detailed functions refer to MULTI V INDOOR UNIT LINE UP & FEATURES OVERVIEW. (Page 90 ~ 91)

Ceiling
Concealed
Duct
Standard
Inverter

Mid
Low

Ceiling
Suspended Unit
Console
Wall
Mounted Unit
Floor
Standing Unit

Ceiling
Mounted
Cassette

Ceiling
Concealed
Duct

4 Way
1 Way
Mid
Low

Convertible & Ceiling


Suspended Unit
Console

Wall Mounted Unit

Mid Temp.
Split
High Temp.
Monobloc

Premium

Standard ll

PREMTA000
PREMTA000A
PREMTA000B

PREMTBB01 PREMTB001

Simple

PQRCVCLOQ

PQRCVC0QW

Simple
for Hotel

PQRCHCA0Q PQRCHCA0QW PQWRHQ0FDB

Dry Contact

Wireless

Wi-Fi

Simple Dry
Contact
PDRYCB000

2 points Dry
Contact
PDRYCB400

Dry Contact for


Thermostat
PDRYCB300

For Modbus
PDRYCB500

LG-IR-WF-1

COMPATIBILITY
TABLE

Controller

X : Compatibility is unavailable

MULTI SPLIT

: Wired remote controller is required

THERMA V

: Compatibility is available

Control Solution & Accessories

90

91

INDOOR UNIT LINE-UP

FEATURES OVERVIEW

1.5 2.2 2.8 3.6 4.5 5.6 6.2 7.1 8.2 9.0 10.6 12.3 14.1 15.8 22.4 28.0

kW

Filter Sign
(Remaining
Time)

Auto rerstart
function
Disable /
Enable

2 Set
point

Occupied /
Unoccupied
Scheduling
Function

Group
Control

Test Run
(Cooling)

Test Run
(Heating)

Model
Information
Monitoring

Auto
Addressing

Refrigerant
Leakage
Detection

Thermo
On / Off
Range
Setting
(Cooling)

Thermo
On / Off
Range
Setting
(Heating)

ARTCOOL Gallery

ARTCOOL Mirror

2 Way Cassette

1 Way Cassette

Mid /
High Statics

Low Statics

Built-in

High Sensible

Type

Btu / h

5k

7k

9k 12k 15k 18k 21k 24k 28k 30k 36k 42k 48k 54k 76k 96k

Static Pressure
11 Step Control
(Only for Ceiling
Concealed
Duct Type)

4th Generation

Wall
Mounted
Unit

NEW

NEW

Standard
4 Way Cassette
(570 x 570)
4th Generation

Ceiling
Mounted
Cassette

4th Generation

Ceiling
Concealed
Duct

4 Way Cassette
(840 x 840)

4th Generation

Fresh Air Intake Units

NEW

NEW

NEW

2nd Generation

Ceiling & Floor Convertible Unit


2nd Generation

Ceiling suspended unit

Floor Standing Unit


with Case

Floor Standing Unit


without Case

Low Temperature

High Temperature

Console
Floor
standing
Unit

4th Generation

4th Generation

2nd Generation

HYDRO KIT

2nd Generation

with Humidifier
Energy
Recovery
Ventilator
without Humidifier
with DX coil
1) If 4th generation indoors are connected to MULTIV WATER S outdoor, some of function will not be activated.
More detailed information, refer to the "MULTI V INDOOR COMPATIBILITY" (page 138~139)

2) If 4th generation indoors are combined to 2nd generation indoors, some of function will not be activated.

COMPATIBILITY
TABLE

1 point
External
Input
(On / Off
control)

Energy
Monitoring

MEMO

Вам также может понравиться