CONTROL SOLUTION
& ACCESSORIES
2016
2016
LG HVAC
SOLUTION
LG Electronics
http://www.lg.com
http://partner.lge.com
Copyright 2016 LG Electronics. All rights reserved.
Distributed by
EUROPE SALES
INFRASTRUCTURE
Tianjin, China
Gebze, Turkey
Noida, India
Production Site
Haiphong, Vietnam
Pune, India
Rayong, Thailand
Manaus, Brazil
LG Electronics products sold in Europe are Made in Korea (Except for ceiling suspended unit).
LG HVAC CONTROL
Individual Control
Premium
PREMTA000
PREMTA000A
PREMTA000B
PREMTB001
Simple
PQRCVCL0QW
Centralized Control
Wireless Remote
Controller
PQWRHQ0FDB
Wi-Fi Controller*
PREMTBB01
PQRCVCL0Q
LINE-UP
LG-IR-WF-1
Centralized Control
Indoor Unit
~ 32
Indoor Unit
~ 128
Indoor Unit
~ 8,192
AC Ez
AC Smart IV
AC Manager IV
PQCSZ250S0
PACS4B000
PACM4B000
Indoor Unit
~ 64
Indoor Unit
~ 256
NEW AC Ez Touch
ACP IV
PACEZA000
Facility Integrator
PI-485
PDI
ACP BACnet
PI-485
Premium (8port)
PQNUD1S40
Standard (2port)
PPWRDB000
PQNFB17C0
For SINGLE /
MULTI / THERMA V
PMNFP14A1
ACS IO Module
(Input / Output Module)
ACP Lonworks
PEXPMB000
PLNWKB000
Indoor Unit
Dry Contact
Control Accessory
PHNFP14A0
PDRYCB400
(Air-Conditioner, ERV)
(For Setback)
PZCWRCG3
Outdoor Unit
AHU Kit
IO Module
Communication Kit
Demand controller
for MULTI V IV
PVDSMN000
Remote
Temperature Sensor
PQRSTA0
For MULTI V IV
PRVC2
DO Kit
KNX Gateway*
PQNFP00T0
LG-AC-KNX4
LG-AC-KNX8
LG-AC-KNX16
LG-AC-KNX64
(Air-Conditioner, ERV)
PSNFP14A0
For Modbus
PDRYCB500
Zone Controller
Control kit
4 Zones by thermostat
ABZCA
PRCKD21E (~ 4 ODUs)
PRCKD41E (~ 8 ODUs)
EEV Kit
(Electronic Expansion Valve)
PRLK048A0 (~ 10HP)
PRLK096A0 (~ 20HP)
PQRCHCA0Q
(Simple for Hotel)
TXV Kit
(Thermal Expansion Valve)
PRDSBM
PACP4B000
(Digital Output Kit)
PQRCHCA0QW
(Simple for Hotel)
PATX13A0E (8 ~ 16HP)
PATX20A0E (18 ~ 26HP)
PATX25A0E (28 ~ 36 HP)
PATX35A0E (38 ~ 46 HP)
PATX50A0E (48~56 HP)
INDIVIDUAL CONTROL
12 Wireless
Remote Controller
10 Standard Wired
Remote Controller
13 Wi-Fi Controller
Indivisual
Control
08 Premium Wired
Remote Controller
CONTROL
SOLUTION
INDIVIDUAL
CONTROL
11 Simple Wired
Remote Controller
On / Off
Fan Speed Control
Temperature Setting
Mode Change
Additional Mode Setting
Auto Swing
Vane Control (Louver Direction)
E.S.P (External Static Pressure)
Reservation
Child Lock
Electric Failure Compensation
Time Display
Filter Sign
Energy Management**
Home Leave
PREMTA000
PREMTA000A
PREMTA000B
PREMTB001
PREMTBB01
PQRCVCL0QW
PQRCVCL0Q
PQRCHCA0QW
PQRCHCA0Q
PQWRHQ0FDB
LG-IR-WF-11)
Weekly / Yearly
Weekly
Sleep, On / Off
-
*
*
CONTROL
SOLUTION
PREMIUM WIRED
REMOTE CONTROLLER
5 inch full touch screen with a premium design
PREMTA000 1)
PREMTA000A 2)
PREMTA000B 3)
Energy Management
Self Energy Management
Features 4)
- Time limit operation / Power consumption monitoring
- Weekly / Monthly / Yearly trend tracking
- Target alert alarm
- Temperature range setting
Improved Scheduling
- Timer / Daily / Weekly / Yearly / Holiday
Display Configuration
Standard Mode
On / Off
* Centralized control (PACS4B000 / PACP4B000 / PQNFB17C0 / PLNWKB000) and PDI (PQNUD1S40 / PPWRDB000) should be installed for this function
Model Name
Function
Yearly Schedule
Check Energy Usage*** / Check Operation Time / Target Setting (Energy, Operation Time) /
Time Limit Operation / Alarm Popup / Initialization Usage Data
****
* Available to save up to a maximum of 20 error histories, 20 holiday reservations and 5 daily event on week
Weekly Schedule
Home Leave
Changeable setting for occupied /
unoccupied status
Temperature
Cooling
Occupied
Home leave
(Unoccupied)
Heating
Cooling
Heating
Indoor
Temperature
Time
Arrive at a Room
Thermo-Off
Leave a Room
Indivisual
Control
10
11
SIMPLE WIRED
REMOTE CONTROLLER
Standard II
Simple
Providing easy control of one or a group of indoor units with various functions
PREMTB001 (White)
PREMTBB01 (Black)
CONTROL
SOLUTION
STANDARD WIRED
REMOTE CONTROLLER
PQRCVCL0QW (White)
PQRCVCL0Q (Black)
Indivisual
Control
PQRCHCA0QW (White)
PQRCHCA0Q (Black)
Simple
Features1)
Model Name
On / Off
Fan Speed Control
Temperature Setting
Mode Change
Additional Mode Setting
Auto Swing
Vane Control (Louver Direction)
E.S.P (External Static Pressure)
Reservation
Time Display
Electric Failure Compensation
Child Lock
Filter Sign
Operation Status LED
Indoor Temperature Display
Wireless Remote Controller Receiver
Size (W x H x D, mm)
Blacklight
Power Consumption Monitoring
Check Model Information
Features1)
PREMTB001 / PREMTBB01
120 x 121 x 16
**
Model Name
On / Off
Fan Speed Control
Temperature Setting
Mode Change
Auto Swing
Vane Control (Louver Direction)
E.S.P (External Static Pressure)
Electric Failure Compensation
Child Lock
Indoor Temperature Display
Wireless Remote Controller Receiver
Size (W x H x D, mm)
Blacklight
* For Ceiling Concealed Duct type
1) Indoor unit should have functions requested by the controller
PQRCVCL0QW / PQRCVCL0Q
PQRCHCA0QW / PQRCHCA0Q
70 x 121 x 16
70 x 121 x 16
12
13
WIRELESS
REMOTE CONTROLLER
WI-FI CONTROLLER
PQWRHQ0FDB
LG-IR-WF-1
Features
Models Applied
CONTROL
SOLUTION
1)
Indivisual
Control
Model Name
On / Off
Fan Speed Control
Temperature Setting
Mode Change
Additional Mode Setting
Auto Swing
Vane Control (Louver Direction)
Reservation
Indoor Temperature Display
Sleep Mode Auto
Size (W x H x D, mm)
PQWRHQ0FDB
Sleep / On / Off
Max. 7 hours
51.4 x 153 x 26
Connectable with the indoor unit having IR receiver Control and monitor
Power supply includes EU-UK-US-AU heads
Easy to install : Wall or desktop mounted
On / Off status and mode indicated by LED light
Automatic firmware Updates*
Additional internet service has to be available and registration user account in Intesis
Home cloud to use Wi-fi controller is mandatory
Intesis Home cloud app is available for android phone or iOS phone
Model Name
LG-IR-WF-1
Set Point
Ambient Temperature
Fan Speed
Specifications
Model Name
LG-IR-WF-1
Enclosure
Dimensions (mm)
81 78 28
Weight (g)
76
Color
White
Power Supply
5VDC 0,2 A NEC Class 2 or Limited Power Source (LPS) and SELV Rated Power supply
Mounting
Wall
LED Indicators
1 Device Status
Operating Temperature
Operating Humidity
Stock Humidity
RoHS Conformity
Certifications
Overview
Case 1. Connection with Indoor Units with IR Receiver
INTESIS
Home
Cloud
Wi-fi
Controller
IR
Smart
Phone
INTESIS
Home
Cloud
Wi-fi
Controller
IR
Smart
Phone
220V
220V
CAC
CAC
14
CENTRALIZED CONTROL
21 ACP IV
18 AC Smart IV
22 AC Manager IV
Centralized
Control
16 AC Ez Touch
CONTROL
SOLUTION
CENTRALIZED
CONTROL
15
20 AC Ez
PQCSZ250S0
PACS4B000
PACP4B000
PACM4B000*
64
32
128
256
8,192
Web
Web
NEW
Ventilation Control
Individual Controller Lock
Error Check
Schedule
Operation History
Visual Navigation
Operation Time Limit
Temperature Limit
Web Access 1)
Web
Interlock Control
* S/W program
1) Assignment of public IP address is required to access central controller through internet.
16
17
CONTROL
SOLUTION
AC EZ TOUCH
Smart management with 5 inch touch screen for small site
NEW
PACEZA000
Features
Centralized
Control
Internet
Web Access
Features
Model Name
PACEZA000
64
Energy Statistics
Self diagnosis
Mode Change
Operation History
Temperature Limit
Web Access 1)
Auto Changeover / Setback
Power Consumption Monitoring (with PDI)
Emergency Alarm Display
External IO Port No.
Energy Mode
DI 1
Compatible Model
Size (W x H x D, mm)
137 x 25 x 121
1) Assignment of public IP address is required to access central controller through internet please contact regional office to have detailed Internet connection configuration
Schedule
Schedule control allows user to set the events in advance to
maximize system performance. Also, by blocking unnecessary
operation, it prevents a waste of energy.
Installation Scene
MULTI V IV
MULTI V III
MULTI V II
Internet
MULTI V
WATER IV
MULTI V
WATER II
MULTI V S
MULTI V Mini
MULTI V SPACE II
MULTI SPLIT
SINGLE SPLIT
ERV
Alarm Indicator
It works when there are some errors or its time to change the oil
or filter. Users can respond immediately according to alarm indicator
therefore HVAC system is monitored consistently.
18
19
CONTROL
SOLUTION
AC SMART IV
Large 10.2 inch touch screen with intuitive GUI (Graphic User Interface) allows easy control
PACS4B000
Features
Centralized
Control
Schedule
Features
Model Name
PACS4B000
128
Visual Navigation
Current operation status on floor plan is checked at one view.
Self diagnosis
Mode Change
Schedule
Operation History
Visual Navigation
Operation Time Limit
Temperature Limit
Web Access 1)
Auto Changeover / Setback
Power Consumption Monitoring (with PDI)
Interlock Control
Virtual Group Control
Emergency Alarm Display
ACS IO Module Interlocking
External IO Port No.
Energy Statistics
Operation Report
Report including control status and other information is provided so
that operation history can be reviewed easily. Data can be sent by
E-mail or stored on USB or external HDD.
DI 2 / DO 2
Interfaceable Products
1) Assignment of public IP address is required to access central controller through internet please contact regional office to have detailed Internet connection configuration
Installation Scene
CH1
CH2
Interlocking
Allows interlocked operation of devices or between digital inputs and
outputs on the AC Smart IV.
MULTI V IV
MULTI V III
MULTI V II
Internet
MULTI V
WATER IV
MULTI V
WATER II
MULTI V S
MULTI V Mini
MULTI V SPACE II
MULTI SPLIT
SINGLE SPLIT
ERV
AHU
(Control Kit)
Emergency Display
Red alert takes up the whole display upon any urgency situation and
all other control signals are blocked to prevent any possible accident.
20
21
ACP IV can be integrated to the web system that allows user can access the control system online
anytime, anywhere without access to PC or specific application
PQCSZ250S0
PACP4B000
Features
Features
Centralized
Control
ACP IV
CONTROL
SOLUTION
AC EZ
Model Name
PQCSZ250S0
32
Ventilation Control
Individual Controller Lock
Error Check
Mode Change
Self Diagnosis
Mode Change
Schedule
Operation History
Visual Navigation
190 x 120 x 17
Power
256
Size (W x H x D, mm)
PACP4B000
Model Name
DC 12V
Temperature Limit
Web Access 1)
Auto Changeover / Setback
Power Consumption Monitoring (with PDI)
Interlock Control
Virtual Group Control
Emergency Alarm Display
ACS IO Module Interlocking
External IO Port No.
DI 10 / DO 4
Interfaceable Products
Installation Scene
Installation Scene
CH5
CH1 ~ 4
MULTI V IV
MULTI V III
MULTI V II
MULTI V
WATER IV
MULTI V
WATER II
MULTI V S
MULTI V Mini
MULTI V SPACE II
MULTI SPLIT
SINGLE SPLIT
ERV
Internet
AC Smart IV
MULTI V IV
MULTI V III
MULTI V II
MULTI V
WATER IV
MULTI V
WATER II
MULTI V S
MULTI V Mini
MULTI V SPACE II
MULTI SPLIT
SINGLE SPLIT
ERV
AHU
(Control Kit)
22
23
CONTROL
SOLUTION
AC MANAGER IV
Up to 32 ACP IV can be connected so that 8,192 indoor units can be controlled and monitored
PACM4B000
Solution Overview
PACP4B000
PACM4B000
PACS4B000
Features
Model Name
Maximum Number of Indoor Units
Individual / Group Control
(On & Off, Mode, Set Point, Fan Speed)
Individual Controller Lock
Error Check
Mode Change
Schedule
Operation History
Visual Navigation
Operation Time Limit
Temperature Limit
Web Access 1)
Auto Changeover / Setback
Power Consumption Monitoring (with PDI)
Interlock Control
Virtual Group Control
Emergency Alarm Display
ACS IO Module Interlocking
Centralized
Control
PDI
AC Ez
Dry Contact
PACM4B000
8,192 (supports 32 ACP IV)
ACS IO
Module
BMS System
PQNFB17C0
PLNWKB000
DO Kit
Comm. Kit
Light
Pump
Fan
Etc
External Device
* Combination: we recommend you to connect separated wattmeter for Indoor units and Outdoor units to have correct power distribution value
Appropriate PI 485 should be used according to PDB
Control Kit
24
25
PDI
CONTROL
SOLUTION
SYSTEM
INTEGRATION DEVICE
POWER DISTRIBUTION
INDICATOR
Facility Integrator
PI-485
PQNUD1S40 (8 port)
Standard
Premium (8 port)
PQNUD1S40
Standard (2 port)
PPWRDB000
PQNFB17C0
ACS IO Module
PPWRDB000 (2 port)
Centralized
Control
Features
Data is backed up so that correct consumption can be checked when power outage occurred
Connector can be separated for convenient installation
Linkable with pulse type power meter
ACP Lonworks
Installation Scene
PLNWKB000
Power Monitoring
Power In
Single Phase
50Hz / 60Hz
220V
Watt Meter
Pulse Signal
PEXPMB000
KNX Gateway
Power In
3 Phase 4 Wire
50Hz / 60Hz
380V
RS485
(LGAP)
PACP4B000
PQNFP00T0
LG-AC-KNX4
LG-AC-KNX8
LG-AC-KNX16
LG-AC-KNX64
PQNFB17C0
Power Cable for 3 Phase 4 Wire
Power Cable for Single Phase
Communication Cable (2 Wire Shielded Cable)
Pulse Signal Wire
* This value could be different with measured power consumption by power meter
Combination : we recommend you to connect separated watt meter for Indoor units and Outdoor units to have correct power distribution value
or
PACS4B000
PLNWKB000
26
27
DO KIT
The module can be connected with PACS4B000 or PACP4B000 if additional control points are
needed not only DI / DO but also AI / AO port. These central controller can control 3rd party device as
pump, security, lighting and so on through DI / DO and AI / AO
PEXPMB000
PQNFP00T0
Features
Features
CONTROL
SOLUTION
ACS IO MODULE
DIGITAL
OUTPUT KIT
Centralized
Control
Model Name
Interface Type
PEXPMB000
NTC 10k
PACS4B000
PACP4B000
PACM4B000
Linkable Products
Communication
I/O
RS-485
Digital Input
Digital Output
Universal Input
Analog Output
Analog Input
PACS4B000
PACP4B000
64 ~ 128
128 ~ 256
8,192
130
224
1,260
16
Min.
Max.
0.68k
177k
PT 1000
803
1,573
Ni 1000
871.7
1,675.2
DC (Voltage)
0V
10V
DC (Current)
0mA
20mA
0V
10V
Analog Output
Digital Input
Binary Input
(Dry Contact)
Digital Output
Normal open
30VAC / 30VDC, 2A
PACM4B000
* Maximum number of Indoor units may be reduced by increasing the number of I/O points.
Installation Scene
CH1 ~ 4
CH6
PACS4B000
or
PACP4B000
PUMP
PACM4B000
DDC
Lighting
Fan
Alarm
* D I : Digital Input, DO : Digital Output, UI : Universal Input, AO : Analog Output / Please contact our regional office to have connectable relay specification for analog output
* Please contact our regional ofce to have connectable relay specication for digital output
28
29
PQNFB17C0
PLNWKB000
Centralized
Control
Features
Features
Process Ability
- EHP Type : 256 units (Indoor / ERV / ERV DX / Hydro Kit / THERMA V)
- AHU Control kit : Maximum 16 units
Controlling
Monitoring Items
On / Off Command
On / Off Status
Lock Setting
Lock Status
* In case of using Modbus, the compatibility is different from BACnet. Refer to manual in detail.
Error Status
Installation Scene
CH5
CH1 ~ 4
Process Ability
- EHP Type : 64 units (Indoor / ERV / Hydro Kit / THERMA V)
- AHU Control kit : Maximum 16 units
conditioner protocol.
Self installation verification function using internet
(Web Server Included)
- Setting gateway
- Diagnosis of communication status on LG Air-conditioner network
Remote Checking
BMS System
Indoor Unit : Max. 256 Units (Air Conditioner & Ventilation) / Indoor Address : 00 ~ FF
Utility Control
CH5
BMS System
CH1 ~ 4
Monitoring Items
On / Off Status
Operation Mode Setting
Fan Speed Status
Lock Status
Air Flow Setting
Set Temperature Status
Current Space Temperature Status
Error Status
Accumulator Power Distribution Status
Accumulator Power Distribution Status
Low Limit Temperature Setting
Mode Lock Status
Peak Operation Ratio Setting
Total Accumulate Power Status
Lighting
Control
Remote Checking
Utility Control
Indoor Unit : Max. 64 Units (Air Conditioner & Ventilation) / Indoor Address : 00 ~ FF
1)
1)
Internet
Internet
PACS4B000
ACP function
Controlling
On / Off Command
Operation Mode Setting
Fan Speed Setting
Lock Setting
Air Flow Setting
Set Temperature Setting
Upper Limit Temperature Setting
Low Limit Temperature Setting
Mode Lock Setting
Peak Operation Ratio Setting
All On / Off Setting
-
Installation Scene
Lighting
Control
PACS4B000
MULTI V IV
MULTI V III
MULTI V II
MULTI V
WATER IV
MULTI V
WATER II
MULTI V S
MULTI V Mini
MULTI V
SPACE II
MULTI SPLIT
SINGLE SPLIT
ERV /
ERV DX
CONTROL
SOLUTION
AHU
(Control Kit)
ACP function
MULTI V IV
MULTI V III
MULTI V II
MULTI V
WATER IV
MULTI V
WATER II
MULTI V S
MULTI V Mini
MULTI V
SPACE II
MULTI SPLIT
SINGLE SPLIT
ERV
AHU
(Control Kit)
30
31
PI 485
PI 485 converts the air conditioners protocol to the RS485 protocol for the central controller
LG-AC-KNX4
LG-AC-KNX8
LG-AC-KNX16
LG-AC-KNX64
PMNFP14A1
PHNFP14A0
PSNFP14A0
Centralized
Control
Easy installation, direct connection to all outdoor units (Communication interface PMNFP14A1,
when needed) and Heat recovering units (Communication interface PHNFP14A0, when needed)
throungh the RS485 Bus.
Great integration flexibility. Using the supplied software LinkBoxEIB, a complete set of communication
objects can be accessed.
Model Name
Direct connection to KNX bus
LG-AC-KNX4
Independent management of communications
LG-AC-KNX8
Power supply : 9 to 24V DC or 24V AC
LG-AC-KNX16
Standard DIN-Rail 6 modules enclosure
LG-AC-KNX64
Maximum connection unit
Features
64
Easy to use tool for the configuration of intesisBox, in a fast and effective way.
It offers the maximum integration possibilities with a minimal knowledge required on the system to be integrated.
LinkBoxEIB
Configuration Software
Installation Scene
Configuration
Software
LinkBoxEIB
(above 1.1.17)
(Only Needed
for Configuration)
EIB Bus
RS485
IntesisBox
LG-AC-KNX4
LG-AC-KNX8
LG-AC-KNX16
LG-AC-KNX64
MULTI V IV
MULTI V III
MULTI V II
1) This product is provided by INTESIS.
CONTROL
SOLUTION
KNX GATEWAY
1)
MULTI V
MULTI V S MULTI SPLIT
WATER IV MULTI V Mini SINGLE SPLIT
MULTI V
MULTI V
WATER II
SPACE II
ERV
* MULTI V PLUS II & MULTI V III & MULTI V IV series do not require any other PI 485 since these series have PI 485 in its outdoor unit PCB.
32
OTHER INTEGRATION
DEVICE LINE-UP
Indoor Unit
Dry Contact
For Modbus
PDRYCB500
Outdoor Unit
AHU Kit
Communication Kit
PZCWRCG3
PVDSMN000
PUCKA0
PRCKA1
PQRSTA0
PRVC2
PUDCA0
PRDCA0
Zone Controller
Control Kit
ABZCA
PQDSBCDVM0
PRCKD21E
PRCKD41E
PWFCKN000
PRLK048A0 / PRLK096A0
Control Accessory
PRVCO
PRDSBM
PATX13A0E / PATX20A0E
PATX25A0E / PATX35A0E
PATX50A0E
Other
Integration Device
CONTROL
SOLUTION
OTHER
INTEGRATION
CONTROL
33
34
35
CONTROL
SOLUTION
DRY CONTACT
Connection between an indoor unit and external devices to control various functions
PDRYCB300
Features
Features
Model Name
PDRYCB000
PDRYCB400
Model Name
Contact Point
1 Contact Point
2 Contact Point
On / Off Control
AC 220V
Mode Control
Power Input
On / Off Control
Rotary Switch 1
Rotary Switch 2
120 x 120
120 x 120
Error Monitoring
Operation Monitoring
Size (W x H, mm)
PDRYCB000
PDRYCB300
PDRYCB400
Other
Integration Device
PDRYCB000
PDRYCB400
Thermo Off
Error Monitoring
Operation Monitoring
Rotary Switch 1
Rotary Switch 2
Size (W x H, mm)
120 x 120
PDRYCB300
AC 220V
AC 220V
Installation Scene
Installation Scene
CN - CC
Control Module
Dry Contact
(Contact point linked
with outer part)
Key Switch
Lighting
Sensor
Fire Alarm
Timer
Motion
Detect Sensor
Door Check
Sensor
CN - CC
System Structure
* Please contact our regional office to have full compatible room controller list
36
37
Connection between an indoor unit and external devices to control various functions
PDRYCB500
PZCWRCG3
Features
Features
Model Name
Other
Integration Device
Function
CONTROL
SOLUTION
DRY CONTACT
PZCWRCG3
Y-type Cable
0.25m Length
Long Cable
9.6m Length
Memory map
Register (hexa)
Name
Range
Notes
00001
Operation
0 1
0 : Stop, 1 : Run
30003
Indoor Temperature
100 390
Degrees C x 100
30100
Error Alarm
0 1
0 : No Error, 1 : Error
0 : Cooling, 2 : Fan, 4 : Heating
40001
0 4
40002
Set Temperature
180 300
Degrees C x 100
40015
0 3
Installation Scene
Installation Scene
<Modbus Communication Function>
Room
Control Master
CN-CC
RCU*
Indoor Unit
...
Max. 8 IDUs
RED (12V)
YL (SIGNAL)
BK (GND)
Controller
* RCU : Room Control Unit.
Indoor Unit
* Please contact our regional office to have full compatible room controller list
1
2
Y type Cable assembly for connecting indoor unit and low cable.
Long Cable assembly for connecting indoor to indoor.
- Please connect cable assembly Y type Cable with already connected indoor unit.
Indoor 2
Indoor terminal block
YL (SIGNAL)
BK (GND)
Indoor 3
Indoor terminal block
YL (SIGNAL)
BK (GND)
38
39
PQRSTA0
ABZCA
Features
Features
It can help to detect the exact room temperature instead of indoor units air temperature sensor
Applied to Ceiling Mounted Cassette, Ceiling Concealed Duct, THERMA V and HYDRO KIT
Extension cable (15m) is included
Indoor Unit
(Duct Type)
Zone Control
sub PCB
Installation Scene
Models Applied
1. Wire to the control box in the indoor unit by removing the existing thermistor and connect the extension cable its place.
2. Cut the extension cable to the appropriate length and connect the screw terminal of the remote sensor.
Wiring Diagram
Extension Cable
CN-ROOM
CN - ZONE
Indoor Unit
AC 24V
Remote
Temperature Sensor
Wired Remote
Controller
Zone Controller
ROOM(External)
THERMOSTAT #1
Damper
Or Relay
ROOM
THERMOSTAT #2
Damper
Or Relay
ROOM
THERMOSTAT #3
Damper
Or Relay
ROOM
THERMOSTAT #4
Damper
Or Relay
ROOM1
ROOM2
Thermostat
Temperature Sensor
Temperature Sensor
Temperature Sensor
ROOM3
ROOM4
Other
Integration Device
ZONE CONTROLLER
CONTROL
SOLUTION
REMOTE
TEMPERATURE SENSOR
40
INPUT / OUTPUT
MODULE
CONTROL
SOLUTION
IO MODULE
41
PVDSMN000
Installation Scene
Demand Control
Provides variable setting for demand control according to input method to reduce power consumption.
This function supports 2 types of input signal : AI (0 ~ 10V, 10 Step) and contact signal (3 Step).
DDC
(Direct Digital Controller)
Capacity Control with
or
Function
MULTI V WATER IV
- Demand control
- Low noise operation
- Output outdoor or indoor unit operation status
- Output error status
MULTI V IV
IO Module
Description
- IO Module is communication interface module for connection
between MULTI V IV and external IO (Input / Output Module) devices.
DDC
(Direct Digital Controller)
Models Applied
Timer
or
Wiring
Contact Signal
Noise Level
MULTI V IV
IO Module
* 8 HP model, Sound power level can be changed by outdoor unit operation status and low noise operation input signal.
Power
AC or DC
Power
AC or DC
AO_4
Error Status
AO_3
Operating Status
AO_2
AO_1
IO Module
Reserved
AI_1
Priority setting
Reserved
Input_LNO
Input_3
Input_2
Input_1
or
OFF
MULTI V WATER IV
MULTI V IV
OFF
ON
Error
Other
Integration Device
Features
42
43
PRVC2
PQDSBCDVM0
Features
Features
Function
Function
- 25oC Low ambient cooling operation by Low ambient kit and hood with damper
(Analog output 0 ~ 10V)
- Demand control
- Low noise operation
- Output outdoor or indoor unit operation status (250VAC, Max 1A)
- Output error status (250VAC, Max 1A)
Error
Display
Description
Description
Low Noise
- Low ambient kit supports -25 C cooling operation by making stable condensing
pressure with reducing air flow rate from hood and damper control given 0 ~ 10V
proportional to condensing pressure.
- Low ambient kit provides IO Module function.
- External snow hood and air damper are required for this item.*
- Transformer and terminal block are included.
o
By DDC
0 ~ 10V
Front
Back
or
By Dry
Contact
Models Applied
Models Applied
MULTI V IV
MULTI V S, MULTI V III, MULTI V MINI, MULTI V SPACE II, MULTI V WATER II, MULTI V WATER S
Installation Scene
Installation Scene
Reference : Air Damper
Main PCB
DDC
(Direct Digital Controller)
0 ~ 10V (Analog Input)
Damper Actuator
(0 ~ 10V)
Transformer
220VAC
-> 24VAC
MULTI V IV
MULTI V III
IO Module
Common
DC 0 ~ 10V
Control
Note : The IO Module can control maximum three actuators. Please, review damper actuators installation manual.
24VAC
Outdoor Unit
Dry Contact
Other
Integration Device
External integration module for cooling operation with -25oC low ambient temperature.
OUTDOOR UNIT
DRY CONTACT
CONTROL
SOLUTION
44
45
PRDSBM
Features
Function
Fan Mode
Fan Mode
Cooling
only
Cooling
only
Advantage
Mode Change
Mode Change
Heating
only
Heating
only
Wiring Diagram
Models Applied
Single Line
Cooling Tower
MULTI V IV
MULTI V S
MULTI V WATER IV
MULTI V WATER S
Pump / Cooling
Tower Controller
<Outdoor
Main PCB >
Wiring
Diagram
Flow
control
valve
Push Button
Push Button
Insert wire method
Pressure
sensor
From Water
Source
Inverter pump
Flow control valve : Regulates the ow or pressure of a uid, normally responding to signals generated by independent devices.
Flow Meter : Measures mass ow rate of a uid traveling through a tube. (The mass ow rate is the mass of the uid traveling past a xed point per unit time.)
Pressure Sensor : Measures the pressure.
Other
Integration Device
Features
CONTROL
SOLUTION
VARIABLE WATER
FLOW CONTROL KIT
46
47
AHU KITS
CONTROL
SOLUTION
AIR HANDLING
UNIT KITS
Features
Communication Kit
PRCKA1 & PUCKA0
List
Description
On / Off
Mode Change
Communication Kit
PUDCA0
PRDCA0
PRCKD21E
PRCKD41E
EEV Kit
TXV Kit
Reservation
Other
Integration Device
PUCKA0
PRCKA1
Control Kit
On / Off, Weekly
Specifications
Communication
Kit
Model
Outdoor
Unit
PRCKA1
MULTI V
PRDCA0
MULTI V
EEV Kit
TXV Kit
Description
280
280
135
330
430
180
PUCKA0
Single Split
280
280
135
PUDCA0
Single Split
330
430
180
PRCKD21E
MULTI V
600
750
285
MULTI V
PRCKD41E
600
750
285
Control Kit
PREMTB001
(White)
Dimensions (mm)
Centralized
Controller
List
Liquid
(ODU)
Dimensions (mm)
Gas
(AHU)
PDRYCB400
PDRYCB300
Modbus
IO Module
(for Outdoor Capacity Control)
PDRYCB500
Type
Min
Max
Mode Change
Digital input*
(Non voltage)
Digital input
(Non voltage)
Voltage output
(220V ~ 230V)
Analog input
0V
10V
Analog input
0V
10V
Monitoring
Model
PDRYCB000
Description
Expansion Valves
Type
PREMTBB01
(Black)
Dry Contact
Thermostat
2 point
Controlling
Combination
Type
Simple
On / Off
On / Off
On / Off
Mode
PRLK048A0
EEV Kit
(Electronic
Expansion Valve) PRLK096A0
4 ~ 10HP
12.7
12.7
217
404
83
Fan Mode
12 ~ 20HP
12.7
12.7
217
404
83
Error Status
PATX13A0E
8 ~ 16HP
15.88
15.88
22.2
22.2
491
331
174
PATX20A0E
TXV Kit
(Thermal
PATX25A0E
Expansion Valve)
PATX35A0E
18 ~ 26HP
15.88
22.2
28.58
28.58
491
331
174
28 ~ 36HP
22.2
28.58
34.92
34.92
491
331
174
38 ~ 46HP
28.58
34.92
41.3
41.3
491
331
174
PATX50A0E
48 ~ 56HP
28.58
34.92
41.3
41.3
561
331
192
* Binary input and output (Open and short), DO is normal open, for more detail please refer to installation manual
Note : DDC or thermostat (filed supplied item) is required to control PRDCA0
PREMTBB01
(Black)
Digital output*
(Non voltage)
Digital output
(Non voltage)
Digital output
(Non voltage)
Digital output
(Non voltage)
Digital output
(Non voltage)
48
AIR HANDLING
UNIT KITS
CONTROL
SOLUTION
AHU KITS
49
Features
Capacity Selection
Control Kit
List
Required Item
Heating / Cooling
Automatic Ventilation
Humidification
kBTU
kW
Maximum Heat
Exchanger Capacity
(kW)
Recommended Heat
Exchanger Volume
(10-3 x m3)
12
3.5
2.2
3.5
9 ~ 10
18
5.0
2.4
5.0
13 ~ 16.5
EBR65102903
24
7.1
2.6
7.1
14 ~ 18
EBR65102904
30
8.0
2.9
8.0
20 ~ 26.5
EBR65102905
36
10.0
3.1
10.0
26.5 ~ 32
EBR65102906
42
12.5
3.4
12.5
28 ~ 36
EBR65102907
48
14.0
4.0
14.0
30 ~ 40
EBR65102908
60
15.0
4.7
15.0
40 ~ 50
EBR77627409
70
19.0
5.2
20.0
60 ~ 70
EBR77627406
85
23.0
5.9
23.0
64 ~ 80
Apply Location
Temperature Sensor
Damper Actuator
- Apply to filter
CO2 Sensor
- Apply to RA duct
- Apply to RA duct
Note : Boundary of specification can be changed through LGAV software. However, please make a specification referring to the above table
*
*
*
-
1) Evaporator Saturated Temperature = 6oC, Air Temperature = 27oC DBT / 19oC WBT
2) Combination allowed only for air-to-air system.
* UU18W.UE4 / UU24W.U44 / UU30W.U44 Available
Detail
Capacity setting
'Option PCB'
(Main PCB)
Option PCB
P/No
Capacity Index
(Btu/h)
Recommended Heat
Exchanger Volume (10-3 x m3)
Maximum Heat
Exchanger Capacity (kW)
EBR52358907
EBR52358908
EBR52358909
EBR52358910
EBR52358911
EBR52358912
EBR52358914
EBR52358915
EBR52358916
EBR52358917
EBR52358913
28k
36k
42k
48k
76k
96k
115k
134k
153k
172k
192k
2.7
3.1
3.4
4.0
5.4
6.3
7.3
8.5
9.5
10.5
11.2
8.6
11.0
13.8
15.4
22.2
28.1
33.7
39.3
45.4
50.4
56.2
22 ~ 26
25 ~ 32
31 ~ 35
33 ~ 45
50 ~ 64
64 ~ 72
72 ~ 88
88 ~ 103
103 ~ 116
114 ~ 129
121 ~ 137
* Evaporator Saturated Temperature = 6oC, Air Temperature = 27oC DBT / 19oC WBT
* Heat exchanger volume (m3) : Pipe cross-section x Tube length
- Pipe cross-section (m2) = x ID2 / 4
- Tube length (m) = Tube length of 1 pipe x Tube step x Tube row
Other
Integration Device
EBR65102901
RA : Return Air, EA : Exhaust Air, OA : Outdoor Air, SA : Supply Air, MA : Mix air (RA + OA)
EBR65102902
Smoke Detecting
List
Option PCB
12kBTU
Filter Alarm
Capacity setting
'Option PCB'
(Main PCB)
Detail
50
AIR HANDLING
UNIT KITS
CONTROL
SOLUTION
AHU KITS
51
Installation Scene
Application
Optional
PUCKA0
Wired Remote
Controller
Centralized
Controller
Expansion Valve
is not Required
Return
Air
PUDCA0
Comm. Kit
PUCKA0
Dry Contact
(Option)
Wired Remote
Controller
*DDC
Exhaust
Air
Outdoor
Air
Supply
Air
Other
Integration Device
Wired Remote
Controller
Refrigerant Piping
Communication Wire
Sensor Signal
* DDC : Digital Direct Controller
Expansion Valve
is not Required
(Monitoring Only)
PRCKA1
EEV Kit
or TXV Kit
Wired Remote
Controller
Centralized
Controller
IO module
PRDCA0
EEV Kit
or TXV Kit
Wired Remote
Controller
*DDC
(Monitoring Only)
MULTI V
Control Kit
Centralized
Controller
Sensors and
Actuators are
Required According
to Control Function
Comm. Kit
PUDCA0
AI (Analog Input) 0 ~ 10V
DI (Digital Input)
DO (Digital Output)
Return
Air
Wired Remote
Controller
(Monitoring Only)
Refrigerant Piping
Communication Wire
Sensor Signal
Exhaust
Air
Outdoor
Air
Supply
Air
52
AIR HANDLING
UNIT KITS
CONTROL
SOLUTION
AHU KITS
53
Application
Application
Wired Remote
Controller
Refrigerant Piping
Communication Wire
Sensor Signal
Comm. Kit
PRCKA1
Dry Contact
(Option)
Refrigerant Piping
Communication Wire
Sensor Signal
*DDC
Comm. Kit
PRDCA0
Wired Remote
Controller
(Monitoring Only)
Return
Air
Exhaust
Air
Outdoor
Air
Supply
Air
Exhaust
Air
Outdoor
Air
Supply
Air
EEV kit
EEV Kit
TXV Kit
or
Simple Control with PRCKA1 Single TXV Kit (without Indoor Unit)
Wired Remote
Controller
Refrigerant Piping
Communication Wire
Sensor Signal
Comm. Kit
PRCKA1
Dry Contact
(Option)
Temperature Sensor
*DDC
Damper Actuator
Return
Air
Exhaust
Air
Outdoor
Air
Supply
Air
Smoke Detector
Fan
- Supply / Return
Control Kit
Expansion Kit
Other
Integration Device
Return
Air
54
55
Indoor
Ceiling Mounted Cassette
Cassette Cover
PTEGM0
PTDCM
PTDCQ
Cassette Panel
Plasma Kit
Outdoor
MULTI V
Air Guide
ABDPG
PBDP9
Suction Grill
PRAGX3S0
PRAGX2S0
PBSGB30
/ PBSGB40
Drain Pan
Canvas
(Compact panel)
PT-QCHW0
PTEGM0
PTPKM0
PTPKQ0
PBSC30 / PBSC40
Ventilation Kit
CO2
Sensor
PRODX20
PRODX30
NEW PHDPA (THERMA V)
ETC.
THERMA V
Refrigerant
Leakage Detector
Indoor
MECHANICAL
ACCESSORIES LINE-UP
Features
Easy Filter Cleaning with Elevation Grill
- Installation inside main body
- Auto horizontal control
- 4 points support structure
STOP
PTVK410
2 Way Cassette
PT-HLC
PTVK420 PTVK430
1 Way Cassette
(Grill Type)
PT-UUC / PT-UUC1 / PT-UTC
(Panel Type)
PT-UUD / PT-UTD
PHLLA
PRLDNVS0
PES-C0RV0
4 Way Cassette
PT-UQC / PT-UMC1
PRIP0
NEW
EEV Kit
NEW
IR Receiver
Operating with wired remote controller* and wireless remote controller included in PTEGM0.
* PREMTB001, PREMTBB01
Models Applied
4 Way Cassette : Refer to PDB for applicable models
PRGK024A0
LGRTV200E
(198 LITERS)
LGRTV300E
(198 LITERS)
PWLRVN000
LGRTV200VE
(198 LITERS)
LGRTV300VE
(198 LITERS)
INDOOR
OUTDOOR
Type 2
Auto Elevation Grille
Cassette Panel
Cassette Cover
Ventilation Kit
Plasma Kit
Suction Grille / Canvas
Drain Pump Kit
Refrigerant Leakage Detection Kit
Independent Power Module
CO2 Sensor
EEV Kit
IR Receiver
Air Guide
Drain Pan
SINGLE SPLIT
MULTI
-
MULTI V
THERMA V
Remark
4-Way Cassette
4-Way / 2-Way / 1-Way Cassette
4-Way Cassette
4-Way Cassette
4-Way Cassette
Ceiling Concealed Duct (Built-in)
Ceiling Concealed Duct
MULTI V 4th Generation Indoors
MULTI V Indoor
Energy Recovery Ventilator
MULTI V Indoors
Ceiling Concealed Duct
MULTI V Outdoor
MULTI V Outdoor / THERMA V
Parts Included
Screws (4EA)
Installation Manual (1EA)
Application
Easy maintenance
56
57
4 Way Cassette
2 Way Cassette
PT-QCHW0
PT-HLC
PT-UUC / PT-UUC1 /
PT-UTC
PTDCM
PTDCQ
PTPKM0
PTPKQ0
Features
Features
Features
Independent vane operation uses separate motors, making it Possible to control all four vanes independently.
The detachable corner design makes it easy to adjust the hanger during installation and to check for leakages in the drain connection pipe.
Models Applied
Models Applied
NEW
MECHANICAL
ACCESSORIES
CASSETTE PANEL
(Panel Type)
PT-UUD / PT-UTD
Indoor
PT-UQC /
PT-UMC1
* Plasma kit and Auto Elevation Grille are not applicable at the same time
Unibody
Shape
620m
Type
4 Way Cassette
2 Way Cassette
1 Way Cassette
SINGLE SPLIT
620m
Specifications
Model name
4-Way
2-Way
1-Way
Suction
Type
PT-QCHW0
Horizontal Grill
PT-UQC
Horizontal Grill
PT-UMC1
Horizontal Grill
PT-HLC
Grill
PT-UUC
Grill
PT-UUC1
Grill
PT-UTC
Grill
PT-UUD
Panel
PT-UTD
Panel
Color
(RAL)
Morning Fog
(RAL 120-4)
Morning Fog
(RAL 120-4)
Morning Fog
(RAL 120-4)
Morning Fog
(RAL 120-4)
Noble White
(RAL 110-1)
Morning Fog
(RAL 120-4)
Noble White
(RAL 110-1)
Noble White
(RAL 110-1)
Noble White
(RAL 110-1)
Dimension (mm)
W
H
D
Applied model
SINGLE SPLIT MULTI SPLIT
Gloss
Weight
(kg)
3.0
620
20
620
1.5 ~ 5.0kw
3.0
700
22
700
2.5 ~ 5.0kw
1.5 ~ 5.0kw
1.5 ~ 5.0kw
5.6
950
25
950
7.1 ~ 15.0kw
7.1kw
7.1 ~ 14.0kw
4.0
1,050
28
640
5.0 ~ 7.1kw
4.6
1,100
34
500
2.1 ~ 3.5kw
4.4
1,100
34
500
2.5 ~ 3.5kw
2.5 ~ 3.5kw
5.5
1,420
34
500
5.0 ~ 7.1kw
O
O
4.6
5.5
1,100
1,420
34
34
500
500
MULTI V
Parts Included
Parts Included
Weight (kg)
NET Gross
Dimensions (mm)
W
H
D
PTDCM
PT-UMC /
PT-UMC1
TP / TN
5.9
8.8
1,157
1,157
268
TM
5.9
8.8
1,157
1,157
310
PTDCQ
TR
5.0
7.2
907
907
268
TQ
5.0
7.2
907
907
310
2.1 ~ 3.5kw
5.0 ~ 7.1kw
Front Panel
MULTI SPLIT
Option
Option
(2.5 / 3.5 / 5.0kw : PTPKQ0)
(7.1kw ~ 15.0kw : PTPKM0) (1.5 / 2.1kw : PTPKQ0)
Built-in
MULTI V
Built-in
Built-in
Built-in
58
59
Fresh air can be supplied from outside through this ventilation kit
PTVK410
PTVK420
PTVK430
ABDPG
PBDP9
PTVK420
PTVK430
ABDPG
Indoor
PTVK410
MECHANICAL
ACCESSORIES
VENTILATION KIT
PBDP9
Features
Features
In some places where natural drainage is not possible, a drain pump is very useful to pump out condensed water from indoor units.
Drain pump assembly (AC 220 ~ 240V, 50 / 60Hz)
Models Applied
Models Applied
* Users can purchase and use PTVK430 in addition to PTVK410+PTVK420 in need to phase in larger outdoor air volume.
Model
12.3kg
Parts Included
MULTI V
CB**L
Standard Inverter CM** / UM**
UB70 / UB85
Econo Inverter
Drain Pump
Included
Included
ABDPG
PBDP9
ABDPG
Included
Application
Dimensions
High head drain pump automatically drains water up to 700mm of drain-head height.
It provides perfect solution for water drainage.
Assembly Diagram
Fixture
Drain pipe
406
700mm
840
435
443
81
13
300mm
* Included in H-Inverter
* Supplied as accessory for Standard Inverter (ABDPG/ PBDP9)
PTVK430
Parts Included
ABDPG / PBDP9
419
840
55mm
PTVK410+PTVK420
60
61
PBSGB30
PBSGB40
PBSC30
PBSC40
Parts Included
For the Suction Grille :
Indoor
Dimensions
Features
High external static pressure facilitates unit use with flexible ducts of varying lengths
When using suction grille, unit requires only 270mm of ceiling space
Blends unobtrusively with any interior decoration
A
A
Models Applied
(Unit : mm)
Model Name
PBSGB30
PBSGB40
(Unit : mm)
Model Name
910
1,188
359
359
56
56
PBSC30
PBSC40
Canvas
Capacity (Btu/h)
ARNU07GB3G2 ARNU09GB3G2 ARNU12GB3G2 ARNU15GB3G2 ARNU18GB4G2 ARNU24GB4G2
PBSGB30
PBSGB40
PBSC30
PBSC40
Application
over 270mm
Grille
Model Name
over 520mm
Category
A
B
821
1,100
274
274
42 ~ 250
42 ~ 250
62
63
CO2 SENSOR
PES-C0RV0
PRLDNVS0
MECHANICAL
ACCESSORIES
REFRIGERANT
LEAKAGE DETECTOR
R410A refrigerant leakage detector makes our space safer
Indoor
Features
1) Model name : PES-C0RV0
2) Specification
Features
Operation Table
CO2 Sensor Reading
<500ppm
Off
500 ~ 700ppm
Low Speed
700 ~ 900ppm
High Speed
>900ppm
3) Description
This detector senses refrigerant leakage and when the refrigerant concentration exceeds 6,000ppm not only it will stop indoor unit operation
but also it will give an alarm using buzzer and sensor LED. (The green and red LED lights blink simultaneously.)
Alarm is ON over 6,000ppm has been maintained 5 seconds, and on the contrary to this, Alarm is OFF under 6,000ppm has been
maintained 5 seconds.
When the alarm of the refrigerant leak detector is switched on the user must ventilate until the alarm is disabled.
The detector has to be installed inside the room and it can be installed 300 ~ 500mm from floor.
Models Applied
Installation Scene
Specifications
Parts
Specifications
Rated Voltage (V)
DC 5.0 5%
Dimensions (W x H x D, mm)
31 x 44 x 20
Weight (g)
Detectable Refrigerant
Sensor
CO2 Sensor
(PES-C0RV0)
CO2 (ppm)
Standard Wired
Remote Controller
Connecting Cable
22
R410A
0 / 6,000 Alarm Off / On
-10 ~ 50
- 40 ~ 60
35
10
80 x 110 x 44.6
80 x 110 x 6.5
2,500
Windows
Closed
Windows
Open
Windows
Closed
Windows
Open
Application
3 Stop Operation and
Ring Alarm
2 Senses Refrigerant Leakage
1,000
0 ERV with CO2 Concentration Control
Time (min)
1 Refrigerant Leakage
64
65
NEW
NEW
IR RECEIVER
MULTI V EEV KIT is specially designed to reduce noise and make comfort environment
IR RECEIVER can be connected to CCD where the customer wants to control by wireless remote
controller
PRGK024A0
PWLRVN000
Features
Features
Designed for wireless control to operate Ceiling concealed duct Operation of Indication lamp (3 colors) Self-diagnosis function
Models Applied
Ceiling Cassette (up to 15kBtu)
Ceiling Concealed Duct (up to 18kBtu)
Wall Mounted (up to 24kBtu)
Application
Models Applied
MULTI V Indoors (Ceiling Concealed Duct, Floor Standing Units)
Application
Note : If you dont use EEV of same specification, Cooling (Heating) capacity may decrease.
Note : Do not install both the IR Receiver and Wired Remote Controller. This may cause malfunctions.
Indoor
MECHANICAL
ACCESSORIES
EEV KIT
66
67
AIR GUIDE
PRIP0
PRAGX*S0
MECHANICAL
ACCESSORIES
INDEPENDENT
POWER MODULE
PRAGX2S0
(14 / 16 / 18 / 20HP)
Independent Power Module is specially designed to close the Indoor EEV at power cut-Off.
50
45
512
Features
Outdoor
Features
33
00
R6
512
564
PRAGX3S0
(8 / 10 / 12HP)
618
60
Models Applied
512
512
00
50
R6
570
652
45
50
Dimensions
618
17kg
50
832
618
564
564
33
33
60
632
632
618
50
45
904
45
760
45
832
832
832
500
832
0
718
0 60
60 R
760
760
904
45
832
50
50
500
45
652
652
900
762
832
500
Each room
570
- ARU*140LTE4
570
- ARU*160LTE4
- ARU*180LTE4
- ARU*200LTE4
900
500
904
MULTI V IV (UX3)
50
- ARU*080LTE4
- ARU*100LTE4
- ARU*120LTE4
50
1st
MULTI V IV (UX2)
900
500
A/C
Switch
Application
500
2nd
0
0 6
45
Power Plug
3rd
570
60
718
45
Main Switch
652
652
50
50
618
832
45
832
50
Each room
Switch BOX
00
00 R6
R6
50
512
512
512
R6
762
500
1st
45
A/C
Switch
500
00
2nd
652
718
900
3rd
632
MULTI V IV (UX3)
Main Switch
Power Plug
9.4kg
760
512
MULTI V IV (UX2)
50
832
33
512
12.3kg
PRAGX3S0
500
Net Weight
22.5kg
500
Gross Weight
45
50
652
Switch BOX
R6
PRAGX2S0
570
762
4th
564
00
Model Name
Outdoor Unit
1 Phase
220V
900
60
3 Phase
400V
512
MULTI V Indoors
45
Models Applied
33
652
564
68
69
DRAIN PAN
PRODX20 / PRODX30
NEW
PHDPA (AWHP)
PHLLA
Features
Interface for solar-thermal system with split-type THERMA V and double coil sanitary tank
Installed at the water pipe, between sanitary tank and solar-thermal system
Dimensions (H x W x D, mm) : 110 x 55 x 22
According to solar systems water temperature, THERMA V controls 3 way valves direction
Installation
Outdoor
Features
Installation Scene
Components : THERMA V system, PHLTA, PHLTC, and field-supplied items.
Outdoor
Service Valve
Indoor
Outdoor Unit
Indoor Unit
Drain Pipe
* In case of the installation of drain pan, drain pipe should be located below the SVC valve.
* Push drain pan in the direction of the arrow.
Brackets can be fixed on the side panel.
This unit does not cover water drops of the outside product.
Connect drain hose to drain pipe for drain condensate.
Hot Water
Solar Heating
Kit
Width x Length
Remark
PRODX20
920mm x 466mm
UX2
PRODX30
1,240mm x 466mm
UX3
PHDPA (AWHP)
478mm x 190mm
Radiator
70
71
Single Coil
LGRTV200E
LGRTV300E
Double Coil
PHRSTA0 (12m)
PHLTB
* The sensor (PHRSTA0) can be purchased separately in case of using other brands sanitary tank. PHRSTA0 is included in PHLTA, PHLTC, PHLTB.
Features
MECHANICAL
ACCESSORIES
DOMESTIC HOT
WATER TANK
LGRTV200VE
LGRTV300VE
Features
LGRTV200E
LGRTV300E
198
580
1,230
45
Stainless steel
Paint Epoxy
White NC
3
60-90
Single
LDX 2101 - Stainless Steel
80
25
25
22
22
1 / 220-240 / 50
287
580
1,680
59
Stainless steel
Paint Epoxy
White NC
3
60-90
Single
LDX 2101 - Stainless Steel
80
25
25
22
22
1 / 220-240 / 50
PHLTA
PHLTA
LGRTV200VE
LGRTV300VE
198
580
1,230
49
Stainless steel
Paint Epoxy
White NC
3
60-90
Double
LDX 2101 - Stainless Steel
80 (With an Heat Pump)
25
25
22
22
1 / 220-240 / 50
287
580
1,680
64
Stainless steel
Paint Epoxy
White NC
3
60-90
Double
LDX 2101 - Stainless Steel
80 (With an Heat Pump)
25
25
22
22
1 / 220-240 / 50
PHLTA
PHLTA
Installation Scene
[ Monobloc ]
PHLTB
Easy to install sanitary water tank for monobloc.
There is a MCCB (Mold Case Current Breaker) to protect the product.
Dimensions (H x W x D, mm) : 250 x 170 x 110
Weight (kg) : 2.1
This unit will be installed outdoor.
General Characteristics
Installation Scene
Characteristics of Exchanger
Hydraulic Connections
- Heat Pump
Hydraulic Connections
- Domestic Hot Water Tank
Electric Connection
Outdoor
[ Spilt ]
Indoor
Water Volume
Diameter
Height
Empty Weight
Tank - Materials
Outer Skin - Materials
Color - White RAL
Additional Electric Heater
Adjustable Thermostat
Exchanger Type
Material Exchanger
Maximum Water Temperature
THERMA V Entry
THERMA V Exit
City Water Entry
Hot Water Exit
Suppy
L
mm
mm
kg
kW
C
C
mm
mm
mm
mm
/ V / Hz
Outdoor Unit
Indoor Unit
General Characteristics
Hot Water
Fan Coil Unit
Water Temperature
Sensor
(PHRSTA0)
Sanitary
Water
Tank
City Water
Radiator
Characteristics of Exchanger
Hydraulic Connections
- Heat Pump
Hydraulic Connections
- Domestic Hot Water Tank
Electric Connection
Water Volume
Diameter
Height
Empty Weight
Tank - Materials
Outer Skin - Materials
Color - White RAL
Additional Electric Heater
Adjustable Thermostat
Exchanger Type
Material Exchanger
Maximum Water Temperature
THERMA V Entry
THERMA V Exit
City Water Entry
Hot Water Exit
Suppy
L
mm
mm
kg
kW
C
C
mm
mm
mm
mm
/ V / Hz
72
73
PIPING ACCESSORIES
LINE-UP
Y BRANCH AND
HEADER BRANCH
SYNCHRO
PIPING
ACCESSORIES
2 Units
SINGLE SPLIT
MULTI SPLIT
MULTI V
ETC
Branch Distributor
PMUB11A
3 Units
PMUB111A
4 Units
PMUB1111A
Liquid Pipe
Gas Pipe
PMBD3620
PMBD3630
PMBD3640
PRHR022
PRHR032
PRHR042
PRAC1
Stopper Valve
2 Units
PMUB11A
3 Units
PMUB111A
4 Units
PMUB1111A
Features
Various Y Branch pipes of different capacities make installation easier
Y Branch and header branch for both gas and liquid are provided
Insulation material is also provided for covering the branches
Models Applied
H-inverter : 10.0 / 12.5 / 13.4kw
Standard inverter : 12.5 / 14.0 / 15.0 / 20.0 / 25.0kw
2 Units
PMBL3620
PMBL5620
2 Units
PMBL1203F0
PRVT120
PRVT780
PRVT980
Application
Drain Hose
PHDHA05T
PHDHA07T
PHDHA05B
PHDHA07B
SINGLE SPLIT
MULTI
2 Branch
3 Branch
4 Branch
MULTI V
Remark
Model name
2 Units
SINGLE SPLIT
Remark
PMUB11A
50:50 (1:1)
MULTI F DX systems
3 Units
PMUB111A
33:33:33 (1:1:1)
MULTI F DX systems
4 Units
PMUB1111A
25:25:25:25(1:1:1:1)
Type
15.88 (5/8)
19.05 (3/4)
25.4 (1)
9.52 (3/8)
12.7 (1/2)
12.7 (1/2)
15.88 (5/8)
6.35 (1/4)
9.52 (3/8)
9.52 (3/8)
12.7 (1/2)
74
75
BRANCH DISTRIBUTOR
DISTRIBUTOR
BOX
Y BRANCH AND
BRANCH KIT MULTI F DX
Refrigerant distribution channel
PIPING
ACCESSORIES
2 Units
PMBL3620
PMBL5620
PMBD3620
PMBD3630
PMBD3640
2 Units
PMBL1203F0
PMBD3620
PMBD3630
PMBD3640
Features
Distribution of refrigerant to various indoor units
3 models (2, 3, 4 Indoor units)
Consists of LEVs inside it
Controlling PCB inside the unit
Features
Models Applied
Application
Models Applied
MULTI F DX systems (Refer to PDB for applicable models)
Parts Included
BD (Banch Distributor) unit (1EA)
Brackets (4EA)
Screws (8EA)
Installation Manual (1EA)
Parts Included
Y Branch for gas side and liquid side (1set)
Installation manual (1EA)
Specifications
Model name
Connectable Indoor Units
Capacity
Casing Colour
Power Source
Power Consumption
Running Current
Dimensions
Packing Dimensions
Net Weight
Connecting Cable
Piping Connection
(Outdoor Unit)
Piping Connection
(Indoor Unit)
Parts
PMBD3620
Number of Indoor Units
(Btu/hr)
/ V / Hz
(W)
(A)
(W x H x D)
(W x H x D)
(mm)
(mm)
1~2
5k / 7k / 9k / 12k / 18k / 24k
Paintingless
1 / 220-240 / 50
10
0.05
302 x 143 x 252
422 x 202 x 300
4.8
4 x 0.75
4 x 0.75
9.52
19.05
6.35 x 2
9.52 x 2
4
8
1
PMBD3630
PMBD3640
1~3
5k / 7k / 9k / 12k / 18k / 24k
Paintingless
1 / 200-240 / 50
10
0.05
302 x 143 x 252
422 x 202 x 300
4.9
4 x 0.75
4 x 0.75
9.52
19.05
6.35 x 3
9.52 x 3
4
8
1
1~4
5k / 7k/9k / 12k / 18k / 24k
Paintingless
1 / 200-240 / 50
10
0.05
302 x 143 x 252
422 x 202 x 300
5.0
4 x 0.75
4 x 0.75
9.52
19.05
6.35 x 4
9.52 x 4
4
8
1
No. of Branch
Distribution Units
Applicable Model
PMBL3620
2 units
PMBL5620
2 units
1, 3
Model Name
Specifications
Gas
Liquid
6.35
6.35
6.35
6.35
15.88
15.88
15.88
15.88
6.35
6.35
15.88
15.88
15.88
15.88
15.88
15.88
6.35
6.35
11 .. 55
.. 55
1115.88
15.88
.5
.5
6.35
6.35
6.35
.5
.56.35
.5
.5
11 .. 55
PMBL1203F0
3 units
1, 3
1 1. 5. 5
1 1. 5. 5
19.05
19.05
1 1. 5. 5
9.52
.5 .5
9.52
9.52
.5 .5
9.52
.5 .5
76
77
Model Name
PRHR022
(2 Branch Unit)
PRHR032
(3 Branch Unit)
PRHR042
(4 Branch Unit)
Liquid
High pressure
Low pressure
Features
Max. 32 indoor units can be connected (Max. 8 indoor units per branch)
It is easy to install due to the automatic search algorithm for piping detection
Subcooling cycle in HR unit makes the system efficiency maximum
PRHR022
HR Unit Reducer
Models Applied
MULTI V IV Heat Recovery
MULTI V III Heat Recovery
MULTI V SYNC II
MULTI V SYNC
PRHR032 /
PRHR042
Specifications
MULTI V IV Heat recovery provides flexible control over individual zones for the users convenience.
Model name
PRHR032
PRHR042
Number of Branch
EA
kW
16 / 32
16 / 48
16 / 58
EA
kW
0.026
0.040
0.040
0.040
Nominal Input
PRHR022
Cooling
kW
0.026
0.040
Net. Weight
Heating
kg
18
20
22
Dimensions (W x H x D)
mm
Indoor Unit
Piping
connections
Outdoor Unit
Liquid
mm (inch)
9.52 (3/8)
9.52 (3/8)
9.52 (3/8)
Gas
mm (inch)
15.88 (5/8)
Liquid
mm (inch)
9.52 (3/8)
15.88 (5/8)
15.88 (5/8)
Low pressure
mm (inch)
22.2 (7/8)
28.58 (11/8)
28.58 (11/8)
High Pressure
Power supply
mm (inch)
19.05 (3/4)
22.2 (7/8)
22.2 (7/8)
/ V / Hz
1 / 220~240 / 50
1 / 220~240 / 50
1 / 220~240 / 50
Individual Control
Office
Zone Control
- Max. of 8 indoor units can be connected for one branch
- Max. of 32 indoor units can be connected for one HR unit
- Same opeational model can be operated by indoor units
with zone control function installed
[Zoning Control]
IT Room
HR Unit
Parts Included
HR unit (1EA)
Hanging bolts M10 or M8 (4EA)
Nut M8 or M10 (8EA)
Kitchen
PIPING
ACCESSORIES
PRHR022
PRHR032
PRHR042
78
79
Y BRANCH AND
HEADER BRANCH (
PIPING
ACCESSORIES
Model Name
Y Branch
Header Branch
4 Branch /
ARBL054
Features
Various Y Branch pipe of different capacities make MULTI V installation much easier.
Y Branch and header branch for both gas and liquid are provided.
Insulation material is also provided for covering the branches.
7 Branch /
ARBL057
Piping Diagram
Heat Pump System
Y Branch for
Indoor Units (2 Pipes)
Header for
Indoor Units (2 Pipes)
4 Branch /
ARBL104
7 Branch /
ARBL107
10 Branch /
ARBL1010
10 Branch /
ARBL2010
Models Applied
MULTI V IV
MULTI V S
MULTI V WATER IV
MULTI V WATER S
Gas Pipe
Liquid Pipe
80
81
PIPING ACCESSORIES
Y Branch pipe for connection of outdoor units
PIPING
ACCESSORIES
[Heat Pump]
R410A MULTI V IV, MULTI V III, MULTI V WATER IV, MULTI V WATER II
[Heat Recovery]
R410A MULTI V IV Heat Recovery, MULTI V III Heat Recovery, MULTI V WATER IV Heat Recovery,
MULTI V WATER II Heat Recovery
(Unit : mm)
(Unit : mm)
2 Outdoor Units
Model Name
Liquid Pipe
416
408
I.D.28.58
I.D.28.58
C
ARCNN21
ARCNN21
C
ARCNN21
111
I.D.22.2
I.D.31.8 I.D.34.9
416
408
I.D.15.88
I.D.28.58
130
BARCNN21
C
Model Name
416
408
I.D.28.58
I.D.41.3
I.D.41.3
I.D.31.8 I.D.34.9
B
ARCNN31
C
ARCNN21
416
408
I.D.15.88
I.D.28.58
I.D.34.9
O.D.34.9
111
111
I.D.22.2
415 70
130375
C
ARCNN31
341
298
I.D.41.3
416
408
I.D.41.3
I.D.28.58
I.D.41.3
I.D.31.8 I.D.34.9
134
I.D.34.9
111
I.D.28.58
I.D.28.58
O.D.34.9
111
I.D.22.2
I.D.28.58
125
A
ARCNN41
B
ARCNN31
C
ARCNN21
341
I.D.44.48 I.D.53.98
I.D.28.58
B C
ARCNN31
Model Name
I.D.41.3
298
I.D.41.3
134
I.D.28.58
I.D.34.9
I.D.44.48 I.D.53.98
111
I.D.12.7
I.D.19.05
I.D.9.52
83
I.D.22.2
.D.38.1 O.D.34.9
I.D.22.2
I.D.28.58
I.D.15.88
I.D.15.88
I.D.19.05
83
I.D.19.05
I.D.19.05
O.D.19.05
I.D.12.7
I.D.15.88
I.D.15.88
70
I.D.12.7
83
I.D.15.88 I.D.12.7
I.D.15.88
I.D.12.7
Liquid Pipe
I.D.22.2 O.D.19.05
Model Name
I.D.15.88
281
70
281
341
298
111
I.D.22.2
I.D.12.7 I.D.9.52
83
I.D.15.88 I.D.12.7
I.D.28.58
I.D.15.88 I.D.12.7
I.D.15.88
83
I.D.19.05
ARCNB31
I.D.34.9
I.D.41.3
I.D.41.3
I.D.15.88
I.D.12.7
I.D.28.58
111
I.D.22.2
O.D.34.9
83
416
408
334
281
83
I.D.19.05
I.D.19.05
83
I.D.31.8
I.D.28.58
111
I.D.22.2
I.D.34.9
I.D.41.31 .D.38.1
I.D.28.58
I.D.15.88 I.D.12.7
I.D.22.2 O.D.19.05
I.D.28.58
I.D.12.7
I.D.19.05
I.D.12.7 I.D.9.52
I.D.19.05
O.D.34. 9
I.D.28.58
I.D.15.88 I.D.12.7
125
130
I.D.15.88
334
281
70
70
I.D.22.2
334
I.D.41.3
I.D.44.48 I.D.53.98 I.D.25.4 O.D.22.2
281
80
4I.D.41.3
Outdoor
Units
I.D.22.2 I.D.19.05
2 Outdoor Units
Liquid Pipe
334
341
I.D.19.05
298
I.D.41.3
83
I.D.12.7 I.D.9.52
I.D.19.05
I.D.19.05
83
I.D.22.2
134
281
334
I.D.19.05
281
I.D.34.9
I.D.28.58
I.D.19.05
83
I.D.25.4 O.D.22.2
111
83
I.D.19.05
I.D.15.88 I.D.12.7
I.D.22.2
I.D.19.05
80
83
I.D.19.05
Liquid Pipe
O.D.34.9
I.D.28.58
I.D.15.88 I.D.12.7
Model Name
4 Outdoor Units
Liquid Pipe
I.D.15.88 I.D.12.7
125
415
415
A
ARCNN41
83
I.D.15.88
I.D.19.05
334
I.D.28.58
375
I.D.41.31
I.D.12.7
I.D.22.22
I.D.31.8 I.D.34.9
334
281
I.D.15.88
331
314
83 I.D.22.2
I.D.15.88 I.D.12.7
111
125
ARCNN41
I.D.12.7
I.D.28.58
334
415
130
375
A
ARCNN41
B
ARCNN31
341
ARCNB21
334
I.D.41.3
O.D.34.9
I.D.19.05
I.D.31.8 I.D.34.9
130
I.D.44.48 I.D.53.98
281
I.D.15.88
I.D.28.58
I.D.34.9
111
I.D.19.05
I.D.12.7 I.D.9.52
111
I.D.22.2
334
I.D.19.05
83 I.D.22.2 I.D.19.05
298
I.D.22.2 I.D.19.05
281
134
I.D.41.3
I.D.44.48 I.D.53.98
281
I.D.25.4 O.D.22.2
I.D.25.4 O.D.22.2
331
416
331
314
408
I.D.12.7
I.D.15.88
314
I.D.15.88
I.D.28.58 111
I.D.28.58
I.D.41.3
I.D.34.9
83
I.D.22.2 I.D.15.88
I.D.19.05
I.D.19.05
I.D.28.58 I.D.15.88
I.D.22.2
I.D.19.05
80
80
375
A
ARCNN41
334
281
331
314
I.D.41.3 I.D.38.1
125 O.D.34.9
I.D.22.2
O.D.19.05
415
83
130
334
I.D.41.3 I.D.38.1
O.D.34.9
125
I.D.28.58
415
130
375
I.D.28.58
I.D.41.3
I.D.22.2 I.D.19.05
I.D.19.05
I.D.41.3
O.D.34.9
I.D.31.8 I.D.34.9
A
ARCNN41
B
B
C
ARCNN31
C
B
C
ARCNN21
331
314
I.D.18.88
I.D.28.58
70
3 Outdoor I.D.22.2
UnitsO.D.19.05I.D.28.58 I.D.15.88 I.D.12.7
I.D.28.58
I.D.22.2 O.D.19.05
70
298
298
B
ARCNN31
C
I.D.12.7 I.D.9.52
I.D.19.05
I.D.15.88
I.D.28.58
I.D.15.88
341
341
I.D.12.7
I.D.28.58
83
2 Outdoor Units
Liquid Pipe
331
314
I.D.15.88
I.D.15.88
I.D.12.7 111
I.D.9.52
I.D.22.2
I.D.19.05
I.D.31.8 I.D.34.9
130
331
314
I.D.28.58
I.D.41.3 I.D.38.1
O.D.34.9
I.D.22.2
O.D.19.05
I.D.28.58
Model Name
A
ARCNN41
I.D.41.3
I.D.28.58
134
281
281
I.D.53.98I.D.19.05
I.D.44.48I.D.22.2
I.D.41.3
I.D.19.05
134
83
I.D.19.05
I.D.19.05
83
I.D.25.4 O.D.22.2
I.D.25.4 O.D.22.2
I.D.15.88 I.D.12.7
I.D.28.58
80
I.D.22.2
ARCNB41
I.D.44.48 I.D.53.98
I.D.41.3
134
I.D.22.2
I.D.19.05
I.D.25.4
I.D.19.05
O.D.22. 2
83
I.D.41.3
I.D.34.9
I.D.41.3
O.D.34. 9
I.D.15.88 I.D.12.7
I.D.15.88 I.D.12.7
80
341
298
334
281
415
375
334
334
375
I.D.28.58
80
I.D.28.58
125
111
82
83
PIPING ACCESSORIES
Y Branch pipe for connection of outdoor units
PIPING
ACCESSORIES
[Heat Recovery]
R410A MULTI V IV Heat Recovery, MULTI V III Heat Recovery, MULTI V WATER IV Heat Recovery,
MULTI V WATER II Heat Recovery
(Unit : mm)
(Unit : mm)
Model Name
Gas Pipe
Liquid Pipe
I.D15.88
I.D15.88
I.D12.7
Model Name
I.D9.52
I.D9.52
I.D6.35
I.D15.88
I.D12.7
ARBLN01621
Liquid Pipe
I.D9.52
I.D9.52
I.D6.35
I.D6.35
I.D15.88
ARBLB01621
I.D12.7
I.D19.05
I.D15.88
I.D12.7
O.D15.88
I.D6.35
I.D15.88
I.D6.35
I.D. 9.52
O.D9.52
I.D12.7
I.D19.05
I.D15.88
I.D12.7
O.D15.88
I.D22.2
I.D19.05
I.D19.05
I.D15.88
I.D9.52
I.D9.52
I.D6.35
I.D12.7
I.D25.4
I.D22.2
ARBLN03321
I.D28.58
I.D9.52
I.D9.52
I.D9.52
I.D6.35
ARBLB03321
I.D12.7
I.D 22.2
I.D6.35
I.D12.7
I.D25.4
O.D19.05
I.D25.4
I.D19.05
I.D15.88
I.D12.7
I.D15.88
I.D19.05
O.D19.05
I.D 22.2
I.D19.05
I.D12.7
I.D12.7
O.D19.05
I.D6.35
I.D. 9.52
O.D9.52
I.D12.7
I.D12.7
O.D19.05
I.D28.58
I.D12.7
I.D15.88
I.D19.05
I.D9.52
I.D 22.2
I.D 22.2
R410A MULTI V IV, MULTI V III, MULTI V PLUS II, MULTI V PLUS, MULTI V S, MULTI V MINI,
MULTI V SPACE II, MULTI V WATER IV, MULTI V WATER S, MULTI V WATER II
Gas Pipe
I.D22.2
I.D15.88
I.D28.58
I.D22.2
I.D15.88
I.D12.7
I.D15.88
ARBLN07121
I.D28.58
I.D34.9
I.D15.88
I.D19.05
O.D19.05
O.D31.8
I.D28.58
I.D22.2
I.D15.88
O.D12.7 I.D6.35
I.D9.52
O.D12.7
I.D34.9
I.D19.05
I.D41.3
I.D34.9
I.D38.1
I.D28.58
I.D9.52
O.D12.7
I.D28.58
I.D38.1
ARBLB14521
I.D34.9
I.D41.3
I.D38.1
I.D41.3 O.D34.9
I.D41.3
O.D38.1
I.D38.1
O.D22.2 I.D15.88
I.D19.05
I.D28.58
I.D41.3
O.D38.1
I.D41.3
I.D22.2
I.D34.9
O.D34.9
I.D38.1
I.D28.58
I.D38.1
I.D34.9
I.D15.88
O.D22.2
I.D19.05
I.D22.2
I.D12.7
O.D15.88
O.D28.58
I.D19.05
I.D22.2
I.D12.7
O.D28.58 I.D19.05
O.D15.88
I.D22.2
R410A MULTI V IV Heat Recovery, MULTI V III Heat Recovery, MULTI V WATER IV Heat Recovery,
MULTI V WATER II Heat Recovery
R410A MULTI V IV, MULTI V III, MULTI V PLUS II, MULTI V PLUS, MULTI V S, MULTI V MINI,
MULTI V SPACE II, MULTI V WATER IV, MULTI V WATER S, MULTI V WATER II
(Unit : mm)
Model Name
(Unit : mm)
Model Name
I.D.53.98
Liquid pipe
I.D.44.48
I.D.34.9
I.D.28.58
X2
175
O.D.44.48
I.D.53.98
2
3
100
I.D.22.2
3
O.D.22. 2
346
379
I.D.15.88
O.D.19.05
I.D.15.88
2 3
I.D19.05
O.D22.2
3
I.D6.35
O.D12.7
471
517
96
I.D.12.7
I.D28.58
2
120
3
O.D15.88
O.D34.9
I.D41.3
130
O.D28.58
I.D22.2
I.D19.05
2
70
I.D38.1
3
90
I.D12.7
125
3
110
I.D28.58
I.D34.9
I.D22.2
I.D38.1
I.D19.52
X2
110
120
I.D38.1
I.D.19.05
2
I.D.22.2
115
I.D.19.05
3
70
I.D22.2
I.D.25.4
I.D.22.2
I.D.19.05
I.D.25.4
O.D.28.58
X2 3
I.D12.7
O.D15.88
I.D25.4
I.D31.8
I.D34.9
I.D.41.3
I.D.25.4
I.D.44.48
I.D38.1 134
I.D41.3
O.D.38.1
2
3
ARBLB23220
Liquid Pipe
I.D.44.48
I.D41.3
I.D38.1
420
490
ARBLN23220
I.D19.05
I.D9.52
I.D12.7
I.D15.88
I.D31.8 O.D22.2
I.D28.58 O.D19.05 I.D28.58
I.D34.9
O.D31.8
I.D22.2
ARBLN14521
I.D15.88
I.D6.35
O.D12.7
I.D9.52
O.D22.2
I.D31.8
I.D12.7
I.D12.7
I.D19.05
I.D31.8
I.D34.9
I.D12.7
I.D19.05
I.D19.05
I.D15.88
I.D15.88
I.D12.7
I.D19.05
I.D12.7
I.D15.88
I.D12.7
I.D31.8
ARBLB07121
Liquid Pipe
I.D19.05
I.D19.05
I.D19.05
I.D28.58
(Unit : mm)
Model Name
I.D6.35
I.D12.7
O.D19.05
I.D25.4
O.D19.05
120
84
85
REFRIGERANT
CHARGING KIT
STOPPER VALVES
Recharging refrigerant after a pump down or when refrigerant is either insufficient or excessive
PIPING
ACCESSORIES
Under 1 / 2 (inch)
PRVT120
PRAC1
Under 7 / 8 (inch)
PRVT780
Under 9 / 8 (inch)
PRVT980
Features
Features
Model Name
Specification
PRVT120
PRVT780
Models Applied
MULTI V III Heat Pump
MULTI V III Heat Recovery
MULTI V PLUS II
MULTI V SYNC II
Mainfold
PRVT980
Capillary Assembly
Usage
This unit can be applied for the additional indoor units installation.
This unit can be applied for each indoor units service.
Refrigerant
Installation
Pin(Closed)
Pin(Open)
86
87
STOPPER VALVES
DRAIN HOSE
Easy drain installation
Case1
In case of the installation of additional
Cut inlet side of the connector, and weld
pipe 1 & 2 : Need to install indoor units)
indoor unit, outlet side connector should
(Room 3 & 4 : In use /the
Room
be cut according to installation pipe.
PIPING
ACCESSORIES
PHDHA05T
PHDHA07T
PHDHA05B
PHDHA07B
"A"
9.52 : 19.05
Room 1
3.0m
9.52 : 19.05
3.0m
Closed
State
Pin(Closed)
Pin(Open)
Stopper Valves
Room 2
5.0m
6.35 : 12.7
3.0m
Features
It reduces the installation time by over 40% with elbow-less drain hose.
Midget drain pump covers maximum 800mm high, featuring easy piping installation.
Models Applied
Room 3
Room 4
Max. 450
In case of installation of additional indoor unit, refrigerant of used indoor unit must be discharged. (Room 3 & Room 4)
If stopper valve is already installed, you can install additional indoor unit without refrigerant loss from the entire system.
After installation of additional indoor unit, you just need refrigerant charging for A section.
In case of the installation of additional
Cut inlet side of the connector, and weld
Then, open the Stopper Valve.
the pipe
indoor unit, outlet side connector should
250
Flexible Hose
Make a Loop Form
(Unit : mm)
Charge Port
9.52 : 19.05
3.0m
9.52 : 19.05
3.0m
Pin(Closed)
Stopper Valves
: 15.88
In case of installation of9.52
stopper
valve,
flare part should be facing towards
additional indoor unit.
10.0m
6.35 : 12.7
3.0m
-When welding, service valve shoud be wrapped by wet cloth.
9.52 : 15.88
3.0m
Room 3
Room 4
Pin(Open)
Open
State
Room 2
Room 1
Model Name
Length
Quantity
PHDHA05T
500mm
30EA
PHDHA07T
700mm
30EA
PHDHA05B
500mm
5EA
PHDHA07B
700mm
5EA
88
89
COMPATIBILITY TABLE
PREMTA000
PREMTA000A
PREMTA000B
Standard ll
PREMTBB01
PREMTB001
PQRCVCLOQ
PQRCVC0QW
ARNU-C4
Ceiling
Mounted
Cassette
Simple
4 Way
Simple
for Hotel
ARNU-C4
ARNU-A4
2 Way / 1 Way
Dry Contact
Wireless
ARNU-A4
High Statics
Mid Statics
Low Statics
ARNU-G4
ARNU-G4
Built-in
MULTI V
FAU
(Fresh Air
intake Unit)
ARNU-Z4
Convertible
& Ceiling
Suspended
Unit
ARNU-A2
Console
ARNU-A4
Floor
Standing
Unit
ARNU-A4
ARNU-U4
ARNU-A4
ARNU-*4 1)
Wall
Mounted
Unit
Simple Dry
Contact
PDRYCB000
2 points Dry
Contact
PDRYCB400
For Modbus
PDRYCB500
LG-IR-WF-1
ARNU-L4
ARNU-A4
HYDRO KIT 2)
Ventilation
Energy
Recovery
Ventilator
Energy Recovery
Ventilator with
DX coil
x
x
X : Compatibility is unavailable
Controller
Wi-Fi
High Sensible
Ceiling
Concealed
Duct
: Compatibility is available
Model
Product
Ceiling Mounted
Cassette
Ceiling
H-Inverter Concealed Duct
Ceiling
Suspended Unit
Ceiling Mounted
Cassette
High
SINGLE SPLIT
Product
Premium
: Compatibility is available but more detailed functions refer to MULTI V INDOOR UNIT LINE UP & FEATURES OVERVIEW. (Page 90 ~ 91)
Ceiling
Concealed
Duct
Standard
Inverter
Mid
Low
Ceiling
Suspended Unit
Console
Wall
Mounted Unit
Floor
Standing Unit
Ceiling
Mounted
Cassette
Ceiling
Concealed
Duct
4 Way
1 Way
Mid
Low
Mid Temp.
Split
High Temp.
Monobloc
Premium
Standard ll
PREMTA000
PREMTA000A
PREMTA000B
PREMTBB01 PREMTB001
Simple
PQRCVCLOQ
PQRCVC0QW
Simple
for Hotel
Dry Contact
Wireless
Wi-Fi
Simple Dry
Contact
PDRYCB000
2 points Dry
Contact
PDRYCB400
For Modbus
PDRYCB500
LG-IR-WF-1
COMPATIBILITY
TABLE
Controller
X : Compatibility is unavailable
MULTI SPLIT
THERMA V
: Compatibility is available
90
91
FEATURES OVERVIEW
1.5 2.2 2.8 3.6 4.5 5.6 6.2 7.1 8.2 9.0 10.6 12.3 14.1 15.8 22.4 28.0
kW
Filter Sign
(Remaining
Time)
Auto rerstart
function
Disable /
Enable
2 Set
point
Occupied /
Unoccupied
Scheduling
Function
Group
Control
Test Run
(Cooling)
Test Run
(Heating)
Model
Information
Monitoring
Auto
Addressing
Refrigerant
Leakage
Detection
Thermo
On / Off
Range
Setting
(Cooling)
Thermo
On / Off
Range
Setting
(Heating)
ARTCOOL Gallery
ARTCOOL Mirror
2 Way Cassette
1 Way Cassette
Mid /
High Statics
Low Statics
Built-in
High Sensible
Type
Btu / h
5k
7k
9k 12k 15k 18k 21k 24k 28k 30k 36k 42k 48k 54k 76k 96k
Static Pressure
11 Step Control
(Only for Ceiling
Concealed
Duct Type)
4th Generation
Wall
Mounted
Unit
NEW
NEW
Standard
4 Way Cassette
(570 x 570)
4th Generation
Ceiling
Mounted
Cassette
4th Generation
Ceiling
Concealed
Duct
4 Way Cassette
(840 x 840)
4th Generation
NEW
NEW
NEW
2nd Generation
Low Temperature
High Temperature
Console
Floor
standing
Unit
4th Generation
4th Generation
2nd Generation
HYDRO KIT
2nd Generation
with Humidifier
Energy
Recovery
Ventilator
without Humidifier
with DX coil
1) If 4th generation indoors are connected to MULTIV WATER S outdoor, some of function will not be activated.
More detailed information, refer to the "MULTI V INDOOR COMPATIBILITY" (page 138~139)
2) If 4th generation indoors are combined to 2nd generation indoors, some of function will not be activated.
COMPATIBILITY
TABLE
1 point
External
Input
(On / Off
control)
Energy
Monitoring
MEMO