Addressable

Fire Alarm Systems

Contents

Introduction

3-7

Addressable Weatherproof Manual


Call Point

24

Premier AL 1-4 Loop Analogue


Addressable Fire Alarm Panel

8-9

Zeta Addressable Explosion Proof


Break Glass Unit

25

Premier AL 5-8 Loop Analogue


Addressable Fire Alarm Panel

10

Zeta Addressable Securetone 2


Sounder

26

Premier AL: Addressable System


Network

11

Zeta Addressable Securetone 2


Combined Sounder & Flasher

27

Premier AL: Alarm Manager Graphics


System

12

Zeta Addressable Securetone 2


Addressable Flasher

28

Simplicity Plus Analogue Addressable


Fire Alarm Panel

13

Maxitone Addressable Sounder &


Sounder Flasher

29

Zeta TCP/IP Communicator

14

Zeta Common Addressable Input Unit

30

Premier Addressable Repeater Panel

14

Zeta Addressable Input Output Units

31

Simplicity Micro Analogue Addressable


Fire Alarm Panel

15

Zeta Addressable Sounder Circuit


Controller

32

Fyreye Extra Analogue Addressable


Combined Smoke & Heat Detector

16

Zeta Addressable Zone Monitoring


Units

33

Fyreye Extra Analogue Addressable


Optical Smoke Detector

17

Zeta GSM Communicator

34

Fyreye Extra Analogue Addressable


Heat Detectors

18

Loop Powered Door Magnet

35

Addressable Remote Indicator LED

19

Zeta Common Sounder Base & Zeta


Common Combined Sounder & Flasher
Base

20

Fyreye Common & Isolator Bases

21

Future Products
Product Compatibility Chart

38

Device Current Consumption

39

Cable Comparison

39

Notes

Fyreye Addressable Reflective Beam


Smoke Detector

22

Addressable Manual Call Point

23

36-37

40-42

Introduction
Zeta Alarm Systems, a trading name of GLT Exports Ltd, was founded
in 1985 and is a privately held UK manufacturer of Fire Alarm, Gas
Detection and Emergency Systems.
Our brand name is well known throughout the industry and is acclaimed in over forty
countries worldwide. We are currently represented in the UK, Europe, Africa, the
Middle East, Southern Asia & South America and this list continues to grow.

Complete System Supplier

Research & Development

To meet the requirements of our ever-changing market,


we pride ourselves on being a complete system
supplier. This means our customers can rely on us for
their entire system requirements.

As with all electronic equipment there is an ever


present drive to manufacture products that are
increasingly effective whilst becoming more cost
sensitive. To meet this objective we spend a significant
percentage of our profits on the continued development
of products, whether it be introducing new items, or
improving existing ones. We have a team of engineers &
designers all of whom have vast industry knowledge &
experience.

One of the main advantages of using a complete system


supplier, compared with a component supplier, is that
system wide compatibility is assured and there is one
point of contact.
Marketing our products as systems has played a vital
role in our worldwide success.

The Future
Our continued inward investment and constant
endeavour to offer the very best products is recognised
by our increased turnover and profit margin year-onyear. Our mission is to support our existing & future
customers by providing them with the highest quality
products, at the most competitive prices.

Customer Support & Product Warranty

As a manufacturer we always follow the market needs


closely to evaluate how we should adapt our product
range. This, combined with welcomed customer
feedback, has proved to be a successful formula for
meeting the current and future industry needs.

Statement Of Quality Policy


We maintain a Quality System, which conforms to BS EN
ISO9001:2008. We are committed, where applicable,
to manufacture in compliance with all appropriate
legislation & regulatory requirements.

We value our customers greatly and to ensure they have


the best experience we have a dedicated support team
who are able to assist with sales, technical or logistical
queries.
Our products carry a full 24 month manufacturers
guarantee from the date of purchase. Our network
of authorised agents is fully trained on the use of our
products and will provide a helpful & friendly service.

Introduction To
Addressable Fire
Alarm Systems

Fire Detection &


Alarm Systems BS5839

Addressable fire alarm systems have


traditionally been associated with the larger,
more complicated applications. However, with
downward price trends, they have become
feasible for smaller systems that would have
historically been designed with conventional
fire alarm equipment.

Risk Assessment

Protocol Statement

In the event of a fire in a building without a written


Fire Risk Assessment, those responsible may face fines
and imprisonment, and/or private litigation.

Zeta Protocol is unique to Zeta Alarm Systems.


All Zeta addressable devices can only be installed
on Zeta control panels. No mixing with any other
manufacturers products or control panels is permitted
and warranty will be void.
What are the advantages of an addressable system
over a conventional alternative?
Each device communicates directly with the
control panel, so it knows the exact location of
any fire or fault reported.
Each device can be assigned a courtesy
label to help identify the device (for instance
Reception).
Each detector reports a smoke value and the
panel then decides whether this is an alarm. This
allows some panels to make detectors more or less
sensitive according to current conditions or time of
day.
All devices (detectors, manual call points,
sounders & interfaces) are all connected on the
same loop of wires.
Detectors are assigned to zones by the panel,
which allows for easier zone changes if the
building layout is altered at a future date.
Addressable panels typically have an event
history which logs past system events.
Some addressable panels allow for complicated
cause & effect programming, where outputs are
only triggered by certain detectors.

The Fire precautions (Workplace) Regulations require


any business employing five or more persons to hold a
written Fire Risk Assessment and Emergency Plan.
This must be periodically reviewed.
The local fire brigade can enforce compliance, and
close any building that does not meet this act.

What the law requires you to do:


Complete a fire risk assessment for your work
place (considering all employees, the public,
disabled people and people with special needs).
Identify and record any significant findings or
persons at risk.
Provide and maintain fire precautions.
Provide information, instruction and training.
Nominate persons responsible to implement
your emergency plan.
Consult employees about the above nominations
and your proposals to improve fire precautions.
Inform other employees who may have work
places in the building about any significant risks
which may affect their safety and co-operate with
them to reduce/control these risks.
If you are not an employer, but control premises
which contain more than one workplace, you are
responsible for complying with fire regulations.
You must establish a suitable means of
contacting the emergency services.
Your employees must co-operate to ensure the
workplace is safe from fire and its effects.

System Zoning
Information
In order to aid identification of the source of a possible
fire, the protected building should be divided into
zones. When deciding on a suitable zoning scheme
for a building, consideration should be given to the
size, any existing fire routines, escape routes, zone
accessibility, and structural fire compartmentation.

The following guide lines should be observed:


If the total floor area of the building is less
than 300m2 then the building needs only one zone,
regardless of the number of storeys.

Manual Call Points


A Manual Call Point is a device which enables
personnel to raise an alarm in the event of a fire
incident by pressing a frangible element to activate the
alarm system.
Manual Call Points should be installed at a height of
1.2m above floor level at easily accessible, conspicuous
positions, on exit routes, at the entry floor landings of
staircases and at all exits to the open air.

If the total floor area is greater than


300m2:
The maximum area for a zone is 2000m2
If a stairwell (or similar) extends beyond one floor it
should be a separate zone.
If a zone covers more than one fire compartment
then the zone boundaries should follow the
compartment boundaries.
The search distance within the zone in order to
ascertain the position of the fire should not exceed
60m. Remember that the use of Remote Indicator
lamps may help to reduce the distance travelled.

1.2m - 1.4m

Manual Call Points should be spaced so that one may


always be found within a maximum distance of 45m
apart or 25m for disabled person.

45m Max. or
25m Max. for disabled person

60m Max.

If a building is divided between occupiers, zones


must not be shared between them.

Detector Information
Automatic Detectors
When deciding on the type of detector to be used in any area it is important to remember that the detector has to
discriminate between a genuine fire and the normal conditions existing therein.

Smoke Detectors

Heat Detectors General

In open spaces under flat horizontal ceilings, every


point should lie within 7.5m of a smoke detector.

In open spaces under flat horizontal ceilings, every


point should lie within 5.3m of a heat detector.

10.6m

7.5m

112m
(10.6m x
10.6m)

56.3m
(7.5m x
7.5m)

Room
boundary

7.5m

5.3m

5.3m

Smoke detection should be generally avoided in the


following areas to avoid unwanted alarms. They should
be protected by means of other detectors such as heat
detectors.
Contamination in dusty areas may cause unwanted
alarms and reduce the life of the detector.
Damp or humid conditions such as showers, bathrooms
and external areas should be avoided as the water
vapour may cause unwanted alarms and reduce the life
of the detector.
Detectors should not be mounted where gases, vapours
or fumes are present.
Detectors should never be used at low temperature
where ice or condensation can affect detector
sensitivity.
Kitchens, garages, welding shops and boiler houses
should generally be avoided.

Room
boundary

3.8m

Heat detectors are designed to either detect a


rapid rise in temperature or to operate at a fixed
temperature. Although they provide a slower response
time than smoke detectors they do provide a method of
protection for areas where smoke detectors cannot be
used.
Heat detectors should not be used for the protection of
life or where extensive property loss may be expected.

Rate of Rise Heat Detectors


Rate of Rise heat detectors respond to both rapid
increases of temperature and to fixed top temperature.

Fixed Temperature Heat Detectors


Fixed temperature heat detectors are available with
different temperature settings, and are normally
installed in kitchens, boiler rooms, etc.

Detection In Apex Roofs

Fire Alarm Sounders

If the ceiling is pitched or sloping, smoke will tend


to rise towards the highest point (apex) of the roof,
therefore detection should be placed in the apex. As
the slope tends to reduce the delay before smoke or
heat reaches the detectors, it is permissible to use a
greater spacing between the detectors mounted there.

Fire Alarm Sounders should be installed throughout the


building with an even distribution, to generally provide
a minimum sound level of 65dB(A) or 5dB(A) above any
background noise which is likely to persist for more
than 30 seconds.

Limits of Ceiling Height

65dB(A)
@ 500Hz - 1000Hz

+5dB(A)
@ 500Hz - 1000Hz
Background noise

Heat
Detector

Smoke
Detector

Heat
Detector

Smoke
Detector

Apex
<150mm

Apex
<600mm

Apex
>150mm

Apex
>600mm

Small Apex
= Standard Spacing

Large Apex
= Extended Spacing

Cabling

Where the alarm may have to arouse sleeping persons


e.g. Hotel bedrooms, nursing homes, etc, a minimum
sound level of 75dB(A) is required, at the bed head with
all the doors shut.

The operation of a Fire Alarm and Detection


System depends on the cabling and connections
between the components. It is essential that
connection between Manual Call Points and
Detectors function correctly when they are
operated.
Cables within the system are required to function
correctly for significant periods after being
attacked by fire. These include the power supply
cables to the control panel, the detection circuits
and the fire alarm sounder circuits. Thus the
cables chosen must be correctly rated to withstand
these conditions.

75dB(A)

All fire alarm sounders in a building should produce the


same sound, distinct from any other audible warning
devices in the building.
Where fire alarm sounders are required in extremely
noisy areas e.g. Machine shops, it may be necessary to
install additional Visual Indication Beacons.

Addressable Fire Alarm Systems /

Premier AL 1-4 Loop Analogue Addressable


Fire Alarm Panel (PR-AL/1, PR-AL/2, PR-AL/3, PR-AL/4)
The Premier AL analogue addressable panels
are a powerful yet user-friendly series of
control panels. They are designed to a high
standard with LPCB approval to EN54, parts
2 & 4. Each panel in this modular series
has considerable processing ability but is
easy to install, programme and operate.
This is supported by comprehensive support
documentation. Panels are housed in steel
enclosures and are finished in hardwearing
epoxy paint.
This panel is ideally suited to installations which require
very complex sounder and control/shutdown functions.
The panels are programmable to meet individual site
requirements by means of a cause & effect matrix.
This is downloaded from a PC, using the Cause & Effect
Edit Programme. Text may be edited via a keyboard or
downloaded from a PC.

Features
1-4 loop addressable fire alarm panel (each with
a 126 device capacity)
LPCB Approved to EN54 parts 2 & 4
Devices can be grouped into 32 zones
Network up to 15 panels (giving a total of 60
loops)
Extensive mode change options by day/night and
special group allocation
Windows based, full upload/download PC
software package
500mA output per loop with highly stable voltage
platform, even under mains-failed conditions
Powerful processing and extensive panel and
loop I/O capability
User-friendly controls (enabled by key switch)
and a clear, unambiguous screen (4 x 20
character LCD display)
Membrane facia with tactile switches
Complies with EMC and LVD Directives

The Premier AL has a 4 line x 20 character backlit


LCD display, showing the first and most recent event.
Other events may be reviewed using the More Messages
facility. User controls are accessed by means of
keyswitch-enabled membrane controls, with password
protection for engineer purposes.
Each panel has a high level of processing power and
each loop has its own processor. The panel allows up
to 126 addresses per loop. All addresses on a loop may
be used for output functions, with 3 independently
programmable output bits per address.
Up to 248 user-definable panel inputs and relay/
programmable alarm outputs can be provided via
expansions boards. Many useful testing and service
functions are also provided. All events may be recorded
on the optional printer and zonal indications are
included as standard.
There is a complete range of compatible accessories
available to support the Premier AL panels to meet
most customer requirements. The addition of a network
card to the panel will allow monitoring, indication and
control of the functions of a networked installation,
allowing signals to be distributed around a large site.

Addressable Fire Alarm Systems /

Premier AL 1-4 Loop Analogue Addressable


Fire Alarm Panel (PR-AL/1, PR-AL/2, PR-AL/3, PR-AL/4)
Optional extras
Panel Printer:
Add to panel to have a permanent record of all events printed.
Part No.

Model

Description

37-201P

PR-AL/1P

Premier AL 1 Loop Addressable FACP, c/w Printer

37-202P

PR-AL/2P

Premier AL 2 Loop Addressable FACP, c/w Printer

37-203P

PR-AL/3P

Premier AL 3 Loop Addressable FACP, c/w Printer

37-204P

PR-AL/4P

Premier AL 4 Loop Addressable FACP, c/w Printer

Repeater interface card:


Fit to panel to allow repeater panels to be added (supplied with repeater).
Network interface card:
Fit to panel to allow up to 15 panels to be networked and to add Global Network Repeater Panels.
The Premier AL 1-4 loop panel can use the Standard Repeater (for a stand alone panel) or a Global Network
Repeater (for a networked system).
Part no.

Model

Description

37-250P

REP-AL/P

Premier AL Repeater Panel

37-255

REP-AL/G

Premier AL Global Network Repeater

Technical Specification
Model

PR-AL/1

PR-AL/2

PR-AL/3

PR-AL/4

Part No.

37-201

37-202

37-203

37-204

Detection Loops

Repeater Model

Premier AL Repeater (REP-AL)

Repeater Part No.

37-220

Mains Voltage

230V AC + 10% / -6% @ 50/60 Hz

System Voltage

28V DC (nominal)

Loop Voltage

24V DC + 9V AC Signal (nominal)

Sounder Alarm Output

2 x 1 A Common @ 24V DC (nominal)

Fault Relay

1 x Relay SELV @ 1A maximum

Fire Relay

2 x Relay SELV @ 1A maximum

Zone Capacity

32 programmable zones

Sounder EOL

3K9 (Orange, White, Red, Gold)

Charge Voltage

27.1 Volt (with battery disconnected)

Charger Size

3 Amp

Aux Supply

500mA max

Batteries (Min. Size)

2 x 12V, 12AH SLA Batteries

Ingress Protection

IP43

Enclosure

410 W x 480 H x 144 D (mm)

Weight

15kg (Excluding Batteries)

Addressable Fire Alarm Systems /

Premier AL 5-8 Loop Analogue Addressable


Fire Alarm Panel (PR-AL/5, PR-AL/6, PR-AL/7, PR-AL/8)
Features
5-8 loop addressable fire alarm panel (each loop
with a 126 device capacity)
Complies fully to EN54 parts 2 & 4
Consists of 2 PR-AL/4 panels networked together
(where each offers the same functionality)
Model

PR-AL/5

PR-AL/6

PR-AL/7

PR-AL/8

Part No.

37-211

37-212

37-213

37-214

Supply Voltage

230V AC +/- 10%

System Voltage

28V DC (Nominal)

Addressable Loops

Loop Voltage

24V + 9 V Data

Loop Capacity

500mA

Sounder Output

4 x 1A @ 24V DC

Sounder EOL

3K9 (Orange, White, Red, Gold)

The panel consists of a large enclosure that houses two


4 loop panels (PR-AL/4) that are networked together
and run off a single power supply. The second panel has
its screen facing inwards behind the blank door (due to
this configuration it is recommended to use the network
repeater with this control panel).

Sounder Delay

0 to 9 Minutes

Fire Relay

4 x Relay, SELV @ 1A

Fault Relay

2 x Relay, SELV @ 1A (Normally


Energised)

Aux Supply

2 x 500mA (Monitored)

This panel will occupy 2 network addresses. When


viewing the loop contents, loop 1 to 4 can be viewed
from the main screen and loops 5 to 8 must be viewed
using the internal display.

Other Connections

Class Change Input, Remote Fault


Input, Remote Evacuate Input, Remote
Reset Input, Remote Silence Input

Operating
Temperature

-0C to +50C

Enclosure Size

960 x 480 x 144mm

Weight

28 KG (Excluding Batteries)

The Premier AL 5-8 loop analogue addressable


fire alarm control panel has been designed to
meet the demand for larger centralised panels,
rather than smaller panels distributed on a
network.

POWER
SUPPLY ON
FIRE

DELAY ON

GENERAL
DISABLEMENT

SYSTEM
FAULT

BUZZER
SILENCED

GENERAL
FAULT

OVERRIDE
DELAY

EVACUATE

SCROLL
MESSAGES

TEST
ALARMS

TEST
DISPLAY

ACCESS MENU
MENU UP

SILENCE
BUZZER

POWER
SUPPLY ON

SILENCE / RESOUND
ALARMS

FIRE

MAINTENANCE

ALERT

SYSTEM
FAULT

<

ENTER

MENU DOWN

BUZZER
SILENCED

GENERAL
FAULT

TEST

ALARM FAULT/
MORE
DISABLEMENT MESSAGES

GENERAL
DISABLEMENT

ALERT

ESCAPE

DELAY ON
MAINTENANCE

RESET

>

SCROLL
MESSAGES

TEST
ALARMS

TEST
DISPLAY

ACCESS MENU
MENU UP

MENU DOWN

ALARM FAULT/
MORE
DISABLEMENT MESSAGES

RESET

ESCAPE

<

ENTER

>

I
ACCESS
CONTROLS

ACCESS
CONTROLS

10

11

12

13

14

15

16

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

ZONAL FIRE AND FAULT INDICATION


17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32

Display to view contents of loops 1 to 4

10

SILENCE
BUZZER

SILENCE / RESOUND
ALARMS

TEST

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

OVERRIDE
DELAY

EVACUATE

ZONAL FIRE AND FAULT INDICATION


1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32

Display to view contents of loops 5 to 8

Addressable Fire Alarm Systems /

Premier AL: Addressable System Network

The addressable system network has the


facility to monitor, indicate and control the
functions of a fire alarm installation, thus
allowing signals to be distributed around a
large site.
The network operates as a global communication system
and does not require a master panel or computer. This
approach reduces cost and no single panel/equipment
failure will disable the entire system.
Each item of equipment connected to the network is
referred to as a node. Each node can be either active
or passive. Up to 15 active nodes plus an additional 17
passive nodes may be connected.
Each node is programmed independently to listen,
respond to, or ignore any or all of the messages sent by
the other nodes on the network.
The network uses RS 485 data communication. Up to a
total network cable length of 5km is possible. All panels
will continue to function in stand-alone mode, even if
the network fails.
The use of a networking system will allow individual
parts of the site to be installed and commissioned prior
to connection to the network.
The operation of the network is such that each node
has total stand alone capability in that its local
operation is not directly affected by its connection
to or disconnection from the network. The ability of
a local control panel to observe events means that it
can be programmed to respond to events elsewhere on
the network. The effect of this capability is that any
control panel is able to respond to any sensor device
connected anywhere on the network. This provides a
possible effective 60 loop control panel distributed
around a single site as a number of smaller units.
Network repeater panels provide the ability to observe
and control elements of the network via a compact unit
which may be conveniently mounted at manned control
points and still provide all essential display and control
facilities.

Features
All talk - selective listen Peer-to-Peer network
wide communication
No master panel or PC required and thus no
single device of failure
Network together:Premier AL panels
Network repeaters
Alarm manager graphics systems
Up to 15 active panels or 60 loops may be
networked together plus an additional 17 passive
nodes
Premier AL panels, network repeaters and alarm
manager graphics systems may be configured as
active or passive
Network communication takes place over a single pair of
wires providing a link to all nodes.
The overall concept can be described as all talk selective listen, which means that every event that
occurs on any node is transmitted into the network.
Each node then decides (via programming) whether or
not it is required to take any action. During quiescent
conditions all active nodes signify their presence on the
network by generating default messages.

11

Addressable Fire Alarm Systems /

Premier AL: Alarm Manager Graphics System

The Alarm Manager system is designed as


a user-friendly tool to view a potentially
complex fire situation.
Once the system has been set up on-site by a qualified
engineer, the keyboard is no longer required, as all
event maps and user buttons will appear on the screen
as necessary to manage the particular event taking
place.
The end user, who may not be technically-minded, will
still be able to operate the system on a daily basis. All
the systems management functions are protected via up
to 7 different password levels.

Features
For use with all Premier AL protocol analogue
addressable control panels
End-user friendly

Technical Specifications

Up to 5 map pages per sensor

The full Alarm Manager package includes;

Up to 32 devices or groups of devices per map


page
Up to 999 maps
2,000 event historic log
All functions protected via up to 7 different
password levels
Identifies each user separately
Up to 3 networks may communicate with the
Alarm Manager

12

When an event occurs, the first map will appear along


with the relevant user controls. There are up to 5
different maps for each sensor showing the device
location in different degrees of accuracy and also a
procedure page which is allocated to each type of event
as prioritised within the configuration menu. There is
also an instantly available current event log.

PC
17 TFT monitor
Network interface for 1 network
Installed Alarm Manager software

Addressable Fire Alarm Systems /

Simplicity Plus Analogue Addressable


Fire Alarm Panel (SP-64, SP-126)
The Simplicity Plus is the ideal introduction to
the world of addressable fire alarm panels.
As its name suggests, it has been designed with ease
of use in mind, using pre-programmed values for its
programming options. The installer simply needs to
configure the loop and enter text labels via the built in
keypad (optional).
The Simplicity Plus is available in 64 or 126 device
versions and has user definable zones, option for zonal
or common alarm operation, options for I/O operation,
alarm verification and user selectable languages.

Features
Single loop addressable fire alarm panel (with
either 64 or 126 device capacity)

It can be connected to an RS232 desktop printer for real


time event log printing (Epson LQ300+ recommended)
and it can also drive a serial repeater model AD-REP
(Part No. 37-156).

Complies fully to EN54 parts 2 & 4

Zonal Addressing

User definable zones

All devices are assigned to a specific zone based on their


address. This removes a programming step and helps to
streamline the commissioning process. The following
table outlines which addresses fall in which zones.

Option for zonal or common alarm operation


Options for I/O operation
Alarm verification (help prevent false alarms)
User selectable languages
Set of changeover relay contacts for fault
condition

Loop & Address

SP-126

SP-64

1: Address 1-16

Zone 1

Zone 1

1: Address 17-32

Zone 2

Zone 2

1: Address 33-48

Zone 3

Zone 3

Set of changeover relay contacts for fire


condition

1: Address 49-64

Zone 4

Zone 4

2,048 event log (fire & fault)

1: Address 65-80

Zone 5

1: Address 81-96

Zone 6

Zone or device disablement


One man test mode
Plug & play, no need for any special tools or
laptop for commissioning

1: Address 97-112

Zone 7

1: Address 113-126

Zone 8

Model

SP-64

SP-126

Fully integrated QWERTY keypad

Part No.

37-160

37-165

All associated devices are loop powered

Supply Voltage

230V AC +/- 10%

230V AC +/- 10%

Flame retardant ABS plastic

System Voltage

24V DC (Nominal)

Number of Loops

Loop Capacity

64 Devices

126 Devices

Number of Zones

Sounder Output

Addressable Sounders Only

Fault Output

28 V Repeat Output to Drive Relay


(Normally Energised)

Fire Output

28 V Repeat Output to Drive Relay

Operating
Temperature

-0C to 50C

Enclosure Size

355 x 275 x 100mm

Weight

3.5 Kg

Alarm Verification
To help prevent false alarms causing a full evacuation,
any smoke detector can be set to alarm verification
mode with a time delay of between 30 seconds and 4
minutes. Should any of these detectors go into alarm
then only the detectors LEDs and sounder/flasher base
(if connected) will activate. Should the alarm not be
cleared with this time delay then a common alarm will
occur.

13

Addressable Fire Alarm Systems /

Zeta TCP/IP
Communicator

Premier Addressable
Repeater Panel (AD-REP)

The Zeta TCP/IP Communicator connects to


the serial port of a Simplicity Plus panel (SP126 or SP-64) to allow the panel to broadcast
alarm or fault information to a monitoring PC
set on any TCP/IP network.

The Premier addressable repeater Panel is a


serial repeater panel for use with the Premier
AD and Simplicity Plus analogue addressable
fire alarm panels.

The Simplicity panel can transmit


the following information;
Device alarm (including loop & address
information)
Device fault (including loop & address
information)
Panel reset
Loop reconfigured
Loop wiring fault
Power supply fault
Earth fault

It is a display only repeater (no controls) which


indicates power, general fault and general fire via
LEDs. Information about the device in fault or alarm is
displayed on the LCD screen.
It also has an internal buzzer to indicate that it requires
attention.

Compatible Panels
NPAD - Premier AD Analogue Addressable Fire
Alarm Panel
SP-64 - Simplicity Plus Analogue Addressable
Fire Alarm Panel
SP-126 - Simplicity Plus Analogue Addressable
Fire Alarm Panel

Clock reset
Evacuate started
Using the Zeta Alarm Watch software, multiple panels
can be monitored from a central PC. The panels can be
grouped by company to give a structured display on the
PC.
Future development of this product will see other
panels being able to interface with the TCP/IP
communicator, starting with the Premier Quatro panel
in early 2010.

14

Features
Addressable repeater panel (display only, no
controls)
Complies fully to EN54 parts 2 & 4
Model

AD-REP

Part No.

37-156

Supply Voltage

20 30 V DC

System Voltage

29V DC (Nominal)

Connections

Supply + ,Supply , Data +, Data -

Operating Temperature

-0C to 50C

Enclosure Size

355 x 275 x 70mm

Weight

1 KG

Addressable Fire Alarm Systems /

Simplicity Micro Analogue Addressable


Fire Alarm Panel (SP-M)
The Simplicity Micro is a unique concept that provides
the best possible entry level solution for addressable
fire alarm systems. It is directed primarily towards small
installations, where traditionally the use of addressable
systems would have been considered cost prohibitive.
The Micro is based upon the successful Simplicity 64
& 126 fire alarm panels and incorporates many of the
larger systems features. These include single loop
connection, minimal commissioning & configuration, 20
character label for each connected device and a 2,048
history event log.

Alarm Verification

Features
Complies fully to
EN54 parts 2 & 4
CE marked
User definable zones
Option for zonal
or common alarm
operation

Set of changeover
relay output in fire
condition
Each detector can
have a sounder or
combined sounder &
flasher base
2,048 event log (fire
& fault)

To help prevent false alarms causing a full evacuation,


any smoke detector can be set to alarm verification
mode with a time delay of between 30 seconds and 4
minutes. Should any of these detectors go into alarm
then only the detectors LEDs and sounder/flasher base
(if connected) will activate. Should the alarm not be
cleared with this time delay then a common alarm will
occur.
Model

SP-M

Zone or device
disablement

Supply Voltage

230V AC +/- 10%

System Voltage

24V DC (nominal)

One man test mode

Number of Loops

Loop Capacity

32 devices

Number of Zones

Slimline enclosure

Plug & play, no


need for any special
tools or laptop for
commissioning

Sounder Output

Addressable sounder only

Flame retardant ABS


plastic

Fully integrated
keypad

Fault Output

28 V repeat output to drive relay


(normally energised)

Fire Output

28 V repeat output to drive relay

Set of changeover
relay output in fault
condition

All associated devices


are loop powered

Operating Temperature

-0C to 50C

Enclosure Size (mm)

355 x 275 x 70mm

Weight

2.8 Kg

Options for I/O


operation
Alarm verification
(help prevent false
alarms)
User selectable
languages

Compatible with conventional detectors to save money

Securetone Micro Addressable


Sounder Base
SM-ASB

Simplicity Micro
SP-M

Range of
input/output
modules

Range of standalone addressable detectors

Securetone Micro Addressable


Sounder & Flasher Base
SM-ASFIB

Addressable Maxitone
Sounder & Flasher
ZAMTF/R

Addressable
Optical Detector
FEAOE2000

Addressable Maxitone Sounder


available in Red ZAMT/R
or White ZAMT/W

Addressable
Opto-Heat Detector
FEAOH2000

Addressable Securetone 2
Sounder Flasher c/w Isolator
available in Red ZAS2/RFI
or White ZAS2/WFI

Addressable
Rate of Rise Heat Detector
FEAHE2000

Addressable
Securetone 2 Sounder
available in Red ZAS2/R
or White ZAS2/W

Addressable
Fixed Heat Detector
FEAHHE2000

Addressable
Manual Call Point
ZT-CP2/AD

15

Addressable Fire Alarm Systems /

Fyreye Extra Analogue Addressable


Combined Smoke & Heat Detector (FEAOH2000)
The Fyreye Extra analogue addressable
combined smoke & heat detector works
with the Zeta Addressable Protocol and is
compatible with all current Zeta analogue
addressable control panels.
The FEAOH2000 is a dual type detector, which reacts to
both smoke & heat independently. It is suitable for use
in places where traditionally an ionisation type detector
may have been chosen.
It comes supplied with a locking grub screw to prevent
unauthorised head removal.

100mm

50mm

Features
Addressable combined smoke & heat detector
DIFT approved
Complies fully to EN54 parts 5 & 7
Twin LEDs to improve alarm indication
Includes locking grub screw to prevent
unauthorised head removal

16

Model

FEAOH2000

Part No.

80-140

Detector Class

Optical Smoke, Rate of Rise & Fixed Heat

Design Standard

EN54 Part 5 & Part 7

Approval

DIFT

Operating Voltage

17-28V DC (Plus Protocol Signal)

Quiescent Current

520A

Alarm Current

2.3mA

Operating Temperature

-10C to +50C

Minimum Continuous Temperature

0C

Maximum Humidity

95% RH Non Condensing

Return Value of 55 (Nominal Alarm Level)

2.4% Obscuration per metre

Return value of 75

Rate of Rise Trigger

Return value of 95

Fixed heat trigger

Coverage

100m

IP Protection Rating

IP43

Start-up Time

30 Seconds

Size, Diameter x Height (with base)

100 x 48 mm (101 x 64 mm)

Weight (with base)

100g (158g)

Addressable Fire Alarm Systems /

Fyreye Extra Analogue Addressable


Optical Smoke Detector (FEAOE2000)
The Fyreye Extra analogue addressable optical
smoke detector is particularly suitable for
detecting optically dense smoke, involving
materials such as soft furnishings, PVC, plastic,
foam and all similar materials which produce
small visible particles (0.5 to 10 m).
The FEAOE2000 works with the Zeta Addressable
Protocol and is compatible with all current Zeta
analogue addressable control panels.
It also comes supplied with a locking grub screw to
prevent unauthorised head removal.

100mm

37mm

Features
Addressable optical smoke detector
DIFT approved
Complies fully to EN54 parts 5 & 7
Twin LEDs to improve alarm indication
Includes locking grub screw to prevent
unauthorised head removal

Model

FEAOE2000

Part No.

80-125

Detector Class

Optical Smoke

Design Standard

EN54 Pt 7

Approval

DIFT

Operating Voltage

17 28V DC (Plus Protocol)

Quiescent Current

480A

Alarm Current

2.3mA

Operating Temperature

-10C to +50C

Minimum Continuous Temperature

0C

Maximum Humidity

95% RH Non Condensing

Return Value of 55 (Nominal Alarm Level)

2.4% Obscuration per metre

Coverage

100m2

IP Protection Rating

IP43

Start-up Time

10 Seconds

Size, Diameter x Height (with base)

100 x 37 mm (101 x 53 mm)

Weight (with base)

95 g (153g)

17

Addressable Fire Alarm Systems /

Fyreye Extra Analogue Addressable


Heat Detectors (FEAHE2000 & FEAHHE2000)
FEAHE2000
The FEAHE2000 is an analogue addressable rate of rise
heat detector. It will respond with a value of 75 if the
detector is triggered by a rate of rise alarm (that is a
fast increase in temperature over a set period of time).
The detector also responds to a fixed temperature of
57C and will return a value of 95 if the detector is
triggered by this condition.

FEAHHE2000
The FEAHHE2000 is an analogue addressable fixed
heat detector. It will respond with a value of 95 if the
detector is triggered through a fixed heat alarm of 90C.

100mm

48mm

Features
DIFT approved
Complies fully to EN54 parts 5 & 7
Twin LEDs to improve alarm indication
Includes locking grub screw to prevent
unauthorised head removal

18

Model

FEAHE2000

FEAHHE2000

Part No.

80-135

80-136

Detector Class

Rate of Rise & Fixed Heat

Fixed Heat Only

Design Standard

EN54 part 5

Approval

DIFT

Operating Voltage

17 to 28V DC (Plus Protocol)

Quiescent Current

440 A

Alarm Current @ 24V DC

2.4mA

Operating Temperature

-10C to 50C

Minimum Continuous Temperature

0C

Maximum Humidity

95% RH non condensing

Alarm Condition

Rate of Rise or Fixed Heat trigger @ 57C

Compatible Bases

FE-CB Common Base, FE-IB Isolator Base, FEA-RB Addressable Relay Base, FEA-SB
Addressable Sounder Base, FEA-SFB Addressable Sounder Flasher Base

Coverage

50m2

IP Protection Rating

IP43

Start-up Time

30 seconds

Size, Diameter x Height (with base)

100 x 48 mm (101 x 64 mm)

Weight (with base)

100g (158g)

Fixed Heat trigger @ 90C

Addressable Fire Alarm Systems /

Addressable Remote Indicator LED


(ZTA-LE2, ZTA-LE2/10 & ZTA-LE3)

ZTA-LE2 & ZTA-LE2/10


The ZTA-LE2 remote LED indicator has been
designed so that it is loop powered and can
be installed anywhere on the loop (it can
either be connected as part of the loop, or
as a spur from the detector it is indicating).
This minimises the amount of wiring from a
detector to its remote indicator.
It has the same address as the detector it is indicating
and will light whenever the panel tells the detector to
do so.
There is also a version that will listen to a number of
consecutive addresses, designed for when there are
more than one detector out of sight.
ON

1 2 3 4 5 6 7 8

ZTA-LE2 & ZTA-LE2/10


+
+

L2

IO

IO

IO

-R

UT

L2

IN

L1

L1

-R

UT

IN

L1

L1

L2

L1

-R

UT

IN

L1

ON

Loop out to next


detector or return
to panel.
1 2 3 4 5 6 7 8

Loop in from
Fire alarm panel

+
+

L2

IO

IO

IO

Loop in from
Fire alarm panel

Loop out to next


detector or return
to panel.

Remote Indicator

+VE
LED
-VE

ZTA-LE3

-R

UT

L2

IN

L1

L1

-R

UT

L2

IN

L1

Remote Indicator

L1

-R

L1

L1

UT

IN

ZTA-LE3

Remote Indicator

IN

L1

Remote LEDs are used in installations where a detector


going into alarm is likely to occur out of sight (for
instance behind a locked door or in a ceiling void). The
indicator will then show the location of the alarm.
The ZTA-LE3 is designed to work with addressable Fyreye
detectors on the Premier AL panel only. They will need
to be programmed to operate and can be triggered from
either a single detector or a group of detectors.

Model

ZTA/LE2

ZTA/LE2-10

ZTA-LE3

48-020A

48-021

Part No.

48-020

Input Voltage

17 - 33V DC

Quiescent Current

1.5 mA

Alarm Current

10mA

Addresses
Repeated

Colour

White Plastic, Red LEDs

Operation Colour

Red

Operating
Temperature

-0C to 50C

0 mA

1-10

Maximum Humidity 95% RH N/C

OU

I
L1

Loop in from
fire alarm panel

The ZTA-LE3 is a low cost alternative to the


fully addressable remote LED indicator ZTALE2.

L2

Loop out to next


detector or
return to panel

IP Rating

IP 43

Size (WxHxD mm)

86 x 86 x 23

Weight

40 g

19

Addressable Fire Alarm Systems /

Zeta Common Sounder Base & Zeta Common


Combined Sounder & Flasher Base (ZTA-CSB, ZTA-CSFIB)
ZTA-CSFIB

ZTA-CSB

The Zeta addressable common sounder base


is essentially an addressable sounder which
does not take an address. Instead it listens to
address 126 and responds to commands sent to
this address.
The combined sounder & flasher version also includes a
loop short circuit isolator, which minimises the number
of devices that would be inoperative in the case of a
short circuit on the loop.
There is no volume adjustment potentiometer, instead
the sounder is supplied set to its maximum volume.

Features
Complies fully to EN-54 part 3
Allows use of addressable detectors
Low current consumption (5.5 mA for combined
sounder & flasher base)
Loop isolation option
Compatible with all Zeta addressable panels
No address to set
All sounder will start at the same time

Although the sounder does not communicate with the


control panel, it must be used in conjunction with
an addressable detector. For monitoring purposes,
the sounder is treated as a conventional sounder and
monitored as part of the loop.

20

Model

ZTA-CSB

ZTA-CSFIB

Part No.

42-510

42-515

Sound Output

85 dB @ 1 metre

Alarm Tone

800-970Hz (0.5s each)

Flasher Colour

N/A

Red
0.3Hz

Flasher Rate

N/A

Operating Voltage

17-30V DC

Quiescent Current

0.4 mA

0.7 mA
5.5 mA

Current Consumption During Alarm

4.0 mA

Size, Diameter x Height

100 x 36 mm

Weight

155g

Addressable Fire Alarm Systems /

Fyreye Common & Isolator Bases


(FE-CB, FE-CB/S, FE-CB/D, FE-IB)

FE-CB

FE-CB/S

FE-IB

FE-CB/D

Features
Common base which is compatible with all detectors
Available in 3 different sizes (standard, shallow &
deep)

Loop + In

Loop + Out

Earth
L2

Earth
L2

- + + - In
Out

L1
Out

L1 Out

FE-CB
FE-CB/S
FE-CB/D

FE_IB
RR-

L1
In

L1 In

Loop - In

Loop - Out

Loop - In

Loop - Out

Loop + In

Loop + Out

Model

FE-CB

FE-CB/S

FE-CB/D

FE-IB

Part No.

80-050

80-050S

80-050D

80-090

Supply Voltage

17-33V DC

Average Quiescent Current At


24V

0A

Alarm Current At 24V

0mA

Isolated Current At 24V

Operating Temperature

-20C to +90C (non condensing or icing)

Max. Wind Speed

Not affected

Connections

L1in, L1out (not used), L2, -R (not used), Earth

Base Size (Diameter x Depth)

100mm x 15mm

Weights

48g

35A

5.4mA

100mm x 8mm

100m x 25mm

100mm x 15mm

42g

61g

50.2g

21

Addressable Fire Alarm Systems /

Fyreye Addressable Reflective Beam


Smoke Detector (ZT-50RA, ZT-100RA)
The Fyreye addressable reflective beam
smoke detector comprises of a single unit
incorporating an infrared transmitter and
receiver. The signal is reflected by a prism
and analysed for smoke presence. Should a
predetermined level be reached, the detector
will signal an alarm.
The system is designed to be mounted so that the beam
will project between 0.3 and 0.6 metres below the
ceiling and parallel to it. Lateral detection may be up to
7.5 metres either side of the beam.

Typical Applications
Beam detectors are generally used for two purposes;
either to cover a wide-open space and/or in places
where several regular smoke detectors would be
aesthetically unacceptable. Such places include;
70mm
120mm

140mm
210mm

126mm

100mm

100mm

9.5mm
Model

ZT-50RA

ZT-100RA

Part No.

47-055

47-056

Supply Voltage

17-33VDC

Range

22

5-50 metres

Shopping centres

Open Plan offices

Heritage sites

Warehouses

Churches or mosques

Factories

Museums

Power stations

Leisure centres

and more

Features
50 or 100 metre addressable reflective beam
smoke detector
Vds approved
Complies fully to;
BS 5839 part 5
EN54 part 12

50-100 metres

Single compact housing

Quiescent Current

5mA

Horizontal or vertical mounting

Operating Temp.

-20C to +55C

Max. Humidity

95%RH N/C

12-24V DC operation

Max. Wind Speed

Not affected

Alarm Current

9 mA

Fire Output

Analogue value to panel

Reflector targeting mode to ease set-up

Fault Output

Analogue value to panel

Microprocessor controlled

Construction

Flame Retardant ABS (Grey / Black).


IP50

Automatic contamination compensation

Detector Size

210 x 117 x 120 mm

Weight

0.7 kg

Low current consumption


Latching or non latching alarm

Selectable sensitivity
Robust construction

Addressable Fire Alarm Systems /

Addressable Manual Call Point


(ZT-CP1/AD, ZT-CP2/AD)

The ZT-CP2/AD is an addressable manual call


point which has been engineered to comply
with EN54 part 11.
It is a resettable call point that signals an alarm with a
yellow flag entering the window area and a red alarm
LED illuminating. The modern housing is supplied with a
back box which has plenty of room for fitting the cables
and also includes 2 x 20mm knockouts for glanded cable
entry.

There are 2 versions available;


ZT-CP1/AD - Which does not have the Perspex protective
cover.

Features
Addressable manual call point
Complies fully to EN54 part 11
Available with or without Perspex protective
cover

ZT-CP2/AD - Which has the protective Perspex cover in


addition to a snaplatch catch that must to be broken
off before the call point cover can be lifted (this acts as
a deterrent to malicious activations and allows double
action activation).

Model

ZT-CP2/AD

ZT-CP1/AD

Part No.

43-305

43-306

Input Voltage

17-33V DC

Element Type

Resettable

Quiescent Current

1.5 mA

Alarm Current

18 mA
Break Snaplatch

Alarm Activation

Lift Perspex

Press Element

Press Element
Operating
Temperature

-20C to 50C

Maximum Humidity 95% RH N/C


IP Rating

IP 43

Size (WxHxD mm)

111 x 100 x 67

105 x 100 x 58

Weight

198 g

175 g

23

Addressable Fire Alarm Systems /

Addressable Weatherproof
Manual Call Point (ZT-CP2/AD/WP)
The Zeta addressable weatherproof call point
(ZT-CP2/AD/WP) is used to manually initiate an
alarm on a Zeta addressable fire alarm system.
As the unit is weatherproof (IP rating 65), it is suitable
for external use, or areas which may have a high build
up of moisture.
The unit has a back box that can be oriented to have
either 2 cable entries, or a single central cable entry
at either the top or the bottom of the unit for the
addressable loop wiring.

Model

ZT-CP2/AD/WP

ZT-CP2/AD/WP/W

Part No.

43-360

43-362

Addressable manual call point

Element Type

Resettable

Weatherproof (IP rating 65)

Alarm Indication

Yellow Flag & Red LED

Complies fully to EN54 part 11

Operating Voltage

17 - 33V DC

Quiescent Current

1mA

Alarm Current

2.9mA

Operating
Temperature

-20C to 50C

Features

Available in red and white

Maximum Humidity 95% RH Non Condensing

24

IP Rating

IP65

Size (Width x
Height x Depth)

87 x 87 x 70mm

Weight

276g

Addressable Fire Alarm Systems /

Zeta Addressable
Explosion Proof Break Glass Unit

(ZTA-BGU/WP)

This explosion proof addressable break glass


unit is manufactured from aluminium in order
to withstand harsh environments. It has a built
in push button activator to signal an alarm
activation.
The address of the unit is set via an internal address
module. Valid addresses are 1 to 126. The unit will
return an analogue value of 16 for normal conditions and
a value of 64 during an alarm condition.

Model

ZTA-BGU/WP

Part No.

43-410

Element Type

Glass

Alarm Activation

Break Glass With Hammer

Type of Protection

Flame proof

Area Classification

Zone 1 & 2

Gas Groups

Group I, II A, II B

Apparatus Standard

IS 2148 / 81

CMRI Certification Number

CMRS / TC / H167

Approvals

CCE

Material

Aluminium LM6

Finish

Anti corrosive epoxy powder


coated

Cable Entry

2 x ET

Gasket

Neoprene

Hardware

Stainless steel (SS-304)

OF

Contact Element

INC

SS

The unit is finished in red anti-corrosive epoxy powder


coating, with 2 x 20mm cable entries. The unit is
supplied with a hammer for operation.

Rating Voltage

500 V, 50Hz AC

Terminals

4 x 2.5mm

Earthing

External: 2 Nos M6
Internal: No M5

Operating Voltage

17-33V DC

Quiescent Current

1.5 mA

Alarm Current

3 mA

Operating Temperature

-20C to 50C

Maximum Humidity

95% RH Non Condensing

IP Rating

IP 65

Cable Entry

TL - Terminals 4Nos. 2.5Sq.mm.


NP - Name & Warning Plate (SS)

105
100

115

NP
TL

185
Hammer

BR
E

C AS E

FIRE

AK GL

IN

215

Chain

Size (Width x Height x Depth) 105 x 215 x 115mm


Weight

1.5 kg

25

Addressable Fire Alarm Systems /

Zeta Addressable Securetone 2


Sounder (ZAS2/R, ZAS2/W)
The Securetone 2 addressable sounder has a
low profile design which makes it ideal for
locations where sounders are required to be
unobtrusive. It is designed to work with the
complete range of Zeta addressable control
panels.

ZAS2/R

The sounder is supplied configured to its maximum


volume. However there is a potentiometer which may be
used to adjust the sound level if required.

ZAS2/W

Features
Complies fully to EN-54 part 3
85 dB @ 1 metre
Low current consumption
Loop isolation option
Compatible with all Zeta addressable panels

An 8 way DIL switch is used to set the address, where


switch 8 is the shadow operative switch. When in the
position ON, the sounder will behave normally. When in
the OFF position, the sounder will listen to commands
without answering to the panel. This allows multiple
sounders to be configured at the same address to allow
for synchronised sounder operation.

Model

ZAS2/R

ZAS2/W

Part No.

42-520

42-521

Sound Output

85 dB @ 1 metre

Alarm Tone

Intermittent Tone - 800-970Hz (0.5s


each)
Pulsed Tone 970Hz (0.5s on, 0.5s off)

Maximum Sounders
64
Per Loop

DIP switch address setting

Short Circuit
Isolator

No

Option to function as shadow sounder

Operating Voltage

17-30V DC

Quiescent Current

0.9 mA

Alarm Current

5.5 mA

Maximum Cable
Size

2.5mm

Operating
Temperature

0C to 40C

Maximum Humidity 95% RH Non Condensing

26

IP Protection
Rating

IP43

Material

Red ABS Plastic

Size, Diameter x
Height

100mm x 37.5mm

Weight

120g

White ABS Plastic

Addressable Fire Alarm Systems /

Zeta Addressable Securetone 2


Combined Sounder & Flasher (ZAS2/RFI, ZAS2/WFI)
The Zeta addressable Securetone 2 combined
sounder & flasher has a low profile design
which makes it ideal for locations where
sounders are required to be unobtrusive.

ZAS2/RFI

It is designed to work with the complete range of Zeta


addressable control panels. It also includes a short
circuit isolator which minimises the number of devices
which would be inoperative in the case of a short circuit
on the loop.

ZAS2/WFI

The sounder is supplied configured to its maximum


volume. However there is a potentiometer which may be
used to adjust the sound level if required.
An 8 way DIL switch is used to set the address, where
switch 8 is the shadow operative switch. When in the
position ON, the sounder will behave normally. When in
the OFF position, the sounder will listen to commands
without answering to the panel. This allows multiple
sounders to be configured at the same address to allow
for synchronised sounder operation.

Features
Complies fully to EN-54 part 3
85 dB @ 1 metre
Includes short circuit isolator
Low current consumption
Loop isolation option

Model

ZAS2/RFI

ZAS2/WFI
42-526

Part No.

42-525

Sound Output

85 dB @ 1 metre

Alarm Tone

Intermittent Tone - 800-970Hz (0.5s


each)
Pulsed Tone 970Hz (0.5s on, 0.5s off)

Maximum Sounders
64
Per Loop

Compatible with all Zeta addressable panels

Short Circuit
Isolator

Yes

DIP switch address setting

Operating Voltage

17-30V DC

Shadow sounder option

Quiescent Current

0.9 mA

Alarm Current

5.5 mA

Maximum Cable
Size

2.5mm

Operating
Temperature

0C to 40C

Maximum Humidity 95% RH Non Condensing


IP Protection
Rating

IP43

Material

Red ABS Plastic

Size, Diameter x
Height

100mm x 37.5mm

Weight

120g

White ABS Plastic

27

Addressable Fire Alarm Systems /

Zeta Addressable Securetone 2


Addressable Flasher (ZASF/RI)
The Zeta addressable Securetone 2 flasher has
a low profile design which makes it ideal for
locations where flashers are required to be
unobtrusive.
It is designed to work with the complete range of Zeta
addressable control panels.
It also includes a short circuit isolator which minimises
the number of devices which would be inoperative in the
case of a short circuit on the loop.

Model

ZASF/RI

Part No.

42-530

Complies fully to EN-54 part 3

Maximum Flashers Per Loop

64

Includes short circuit isolator

Short Circuit Isolator

Yes

Low current consumption

Operating Voltage

17-30V DC

Quiescent Current

0.9 mA

Alarm Current

2.5 mA

Maximum Cable Size

2.5mm

Operating Temperature

0C to 40C

Maximum Humidity

95% RH Non Condensing

IP Protection Rating

IP43

Material

Red ABS Plastic

Size, Diameter x Height

100mm x 37.5mm

Weight

120g

Features

Loop isolation option


Compatible with all Zeta addressable panels
DIP switch address setting

28

Addressable Fire Alarm Systems /

Maxitone Addressable Sounder


& Sounder Flasher (ZAMT/R, ZAMT/W, ZAMTF/R)

120mm

126mm

The Maxitone addressable sounder is a large


horn sounder suitable for many applications.
It can be used on any panel using the Zeta
Addressable Protocol. It is available as a
sounder only in red or white, or as a combined
sounder flasher in transparent red. It is
suitable for indoor & outdoor use
It has a large back-box with knockout cable entries,
which has plenty of room for fitting the cables.
It has an internal 8 way dip switch for setting the device
address, and a sound output of 94 dBA @ 1m.

107mm

Both units have a built in short circuit isolator to provide


system integrity in the event of cable damage.

Model

ZAMT/R

ZAMT/W

ZAMTF/R

Part No.

42-007

42-007A

42-

White

Red

0.6mA

0.6mA

Colour

Red

Supply Voltage

17-33V

Standby Current

0.6mA

Active Current

12mA

12mA

15mA

Sound Output

94dB

94dB

94dB

Number of Tones

2 (Controlled by FACP)
N/A

Red LED 2Hz

Flasher

N/A

Operating Temp.

0C to 50C

Max. Humidity

95% RH N/C

IP Rating

IP 65

Size

124 x 129 x 100 mm

Weight

200g

29

Addressable Fire Alarm Systems /

Zeta Common Addressable Input Unit


(ZIU)

The Zeta addressable input unit (ZIU) is used


to interface external equipment which has a
volt free normally open relay output to any
Zeta addressable fire alarm system. The input
is monitored with a 47K end of line resistor.
The unit has a built in loop short circuit isolator to help
keep the unit operational in the event of a problem on
the addressable loop wiring.
The unit has internal LED indications for loop isolator
active, fault on input and alarm (panel controlled).
During the system set-up, the led can be removed from
this box to allow these LEDs to be viewed.

Fault Current

2.8mA

Isolating Current

7.3mA

Input End Of Line

47K Resistor

Device Normal Resistance


(Return Value 16)

10K to 75K

Device Open CCT Fault


Resistance (Return Value 4)

85K to open circuit

Device Alarm Resistance


(Return Value 64)

0K to 5K

Operating Temperature

0C to 50C

Maximum Humidity

95% RH Non Condensing

IP Rating

IP 43

Size, Width x Height x Depth

127 x 88 x 57mm

Weight

220g

In

Out

Serial No

2.9mA

ZIU Pt No: 48-100


ZIOU Pt No: 48-105
ZSCC Pt No: 48-110

Hundreds

Tens

Units

901

901

901

Address

78

Alarm Current

Loop
-

78

900uA

78

Quiescent Current

Interface Unit

456

17 33V DC

456

Operating Voltage

456

48-100

23

Part No.

23

ZIU

23

30

Model

Addressable Fire Alarm Systems /

Zeta Addressable Input Output Units


(ZIOU, ZIOU/230)

The Zeta addressable input output units (ZIOU


& ZIOU/230) are used to interface external
equipment to any Zeta addressable fire alarm
system.
It has a switch monitoring input with a 47K end of line
resistor and a volt free SELV relay output.
There are two versions available, one for switching
low voltage (ZIOU) and the other for switching mains
(ZIOU/230).
As with all addressable interfaces, the outputs are
controlled by the panel to which they are connected.
Consequently the interfaces will behave differently on
different panels, i.e. some may allow the outputs to
be programmed whilst others will have a default preprogrammed operation.

ZIOU

ZIOU/230

Part No.

48-105

48-106

Operating Voltage

17 33V DC

Quiescent Current

900uA

Alarm Current

10.6mA

www.gltexports.com
-

MADE IN THE UK

Loop
+

IN

OUT

147k EOL
MON I/P

Power

Link
Isolate
Section

Alarm
Fault
Interface Unit
ZIOUH PT NO.40-06

Fault Current

2.8mA

Isolating Current

7.3mA

Input End Of Line

47K

Device Normal Resistance


(Return Value 16)

10K to 75K

Device Open CCT Fault


Resistance (Return Value 4)

85K to open circuit

Device Alarm Resistance


(Return Value 64)

0K to 5K

Relay Rating

1 Amp SELV
Only

Operating Temperature

0C to 50C

Maximum Humidity

95% RH Non Condensing

IP Rating

IP43

Size, Width x Height x Depth

127 x 88 x 59mm

Weight

220g

Isolator

Compatible with
Zeta Addressable
Fire Alarm System
Panels Only

AUX 1240VAC 5A
NC

901

CM

456

NO

78

901

78

901

456

78

Units
23

Tens
23

Hundreds
23

456

5 Amp 230V
AC Resistive

Serial No

Model

Address Settings

The unit has a built in loop short circuit isolator to help


keep the unit operational in the event of a problem on
the addressable loop wiring.
It has 3 indication LEDs on the front of the unit. One for
alarm, one for local fault and one for addressable loop
fault (isolator active).

31

Addressable Fire Alarm Systems /

Zeta Addressable Sounder Circuit Controller


(ZSCC, ZSCC/4)

The Zeta addressable sounder circuit


controllers (ZSCC & ZSCC/4) are used to
connect any conventional alarm warning
devices (for instance sounders, flashers or
bells) to any Zeta addressable fire alarm
system. It needs external power to be supplied
from a suitable 24V power supply.

ZSCC

ZSCC/4

The unit has a built in loop short circuit isolator to help


keep the unit operational in the event of a problem on
the loop wiring.
It has 3 indication LEDs on the front of the unit, one for
alarm, one for local fault and one for addressable loop
fault (isolator active).

Operating Voltage

17 33V DC

Quiescent Current

900uA (6.8 mA from ext PSU)

Alarm Current

10.6mA (10mA +
sounder load from
PSU)

Fault Current

2.8mA (10mA from PSU)

Isolating Current

7.3mA (6.8 mA from ext PSU)

Sounder End of
Line

47K

Line Monitoring
Conditions

Open & Short Circuit

Sounder Output

1 Amp (If Ext PSU Allows)

Operating
Temperature

0C to 50C

Interface Unit

42.4mA (10mA per


circuit + sounder
load from PSU)

ZIU Pt No: 48-100


ZIOU Pt No: 48-105
ZSCC Pt No: 48-110

Snd Supply

Tens

Units

901

901

901

78

Hundreds

456

Address

Quad Sounder Unit

Line
Isolated

220g

400g
901

456

Address

23

Units

901

23

Tens

901

23

Hundreds

78

Weight

Snd 2 O/P

Snd 3 O/P

Snd 4 O/P

Snd
Snd
Active Fault

Snd
Snd
Active Fault

Snd
Snd
Active Fault

Snd
Snd
Active Fault

Serial No

78

195 x 143 x 79mm

78

127 x 88 x 59mm

456

IP 43

Size

456

IP Rating

Snd 1 O/P

Loop In/Out

Maximum Humidity 95% RH Non Condensing

32

Serial No

78

Number of
Sounder Circuits

78

48-111

456

48-110

456

Part No.

23

ZSCC/4

23

ZSCC

23

Model

Snd Supply

Addressable Fire Alarm Systems /

Zeta Addressable Zone Monitoring Units


(ZTZM/1, ZTZM/4)

Zone monitors are used to connect


conventional detectors to an addressable loop.
This may be for economic reasons (due to
conventional detectors being less expensive
compared with addressable ones), or for
technical reasons (the required detector may
not be available in an addressable form (for
instance flame detectors).
The Zeta addressable zone monitoring units have either
1 (ZTZM) or 4 (ZTZM/4) detection circuits and both
require external power to be supplied from a suitable
24V PSU.
The unit has a built in loop short circuit isolator to help
maintain operation in the event of a problem on the
addressable loop wiring. It has internal indication LEDs
for zone alarm (red) and zone fault (yellow) for each
of the detector circuits. It also has one for addressable
loop fault (isolator active).

1.09mA (37mA
from ext PSU)

1.09mA (105mA
from ext PSU)

Fault Current
(Max.)

1.09mA (55mA
from ext PSU)

1.09mA (175mA
from ext PSU)

Isolating Current

7.2mA (22mA from


ext PSU)

7.2mA (50mA from


ext PSU)

Sounder End Of
Line

2K2

Line Monitored
Conditions

Open & Short Circuit & Alarm

Alarm Condition

Zone current >14mA

Operating
Temperature

0C to 50C

Zone
1

Loop In/Out

Line
Isolated

Zone
Alarm

Zone
Fault

Serial No

Hundreds

Tens

Units

901

901

901

78

Alarm Current
(Max.)

78

1.08mA (40mA
from ext PSU)

78

Quiescent Current

1.08mA (22mA
from ext PSU)

Quad Sounder
Monitoring Unit

456

17 33V DC

Zone Supply

23

Operating Voltage

456

ZTZM/4

23

ZTZM/1

23

Model

456

Address

Quad Sounder
Monitoring Unit

Zone
1

Zone
2

Zone
3

Zone
4

Maximum Humidity 95% RH Non Condensing


Zone
Fault

Zone
Alarm

Zone
Fault

Zone
Alarm

Zone
Fault

Zone
Alarm

Zone
Fault

Serial No

901

Zone Supply

23

Units

901

23

Tens

901

23

Hundreds

78

220g

78

Weight

Zone
Alarm

78

127 x 88 x 59 mm

456

Size

Loop In/Out

Line
Isolated

456

IP43

456

IP Rating

Address

33

Addressable Fire Alarm Systems /

Zeta GSM Communicator

(GSM-COM)

Zeta GSM communicator is an interface that


allows a fire alarm panel to send a SMS text
message in the event of an alarm or a fault.
The communicator accepts a standard Mobile Phone
SIM card, and is then programmed with the alarm
information & phone numbers via a PC.
The unit can run on any power supply between 9 & 24V
DC.
The unit has 4 inputs & 2 user definable outputs.
The outputs can be manually operated by dialling the
GSM communicator then entering a password.

B
C
D

PC Rs232

I
K

9-24V DC

34

Antenna

Metal House

Antenna Cable
Adaptor

Main PCB

Antenna
Connection

SIM card Case

GSM Module

Power Supply
Terminals 9-24V DC

RS232 Connector
for Programming

Connectors
GSM LINE
PSTN LINE
In1/2/3 (User
Programmable)
In4 (DIRECT GSM
Function)
COM Common
Point IN1...IN4
OUT1/2 (User
Programmable)
OUT3 failure of
GSM line
OUT4 failure of
wired line

Push button

Model

GSM-COM

Part No.

48-900

Supply Voltage

9-24V DC

Standby Current

200mA

Active Current

500mA

Transmission Frequency

GSM 900/1800 MHz

Inputs (Type)

4 x N/O switch monitor

Input Quantity

(3 user definable, 1 reserved)

Outputs (Type)

4 x Open Collector 100mA Max

Output Quantity

(2 user definable, 2 reserved for line faults)

Operating Temperature

0C to 60C

Size (PCB Only)

150 x 101 x 27mm

Weight (PCB Only)

70g

Size (ex antenna)

234 x 165 x 80mm

Weight

200g

Addressable Fire Alarm Systems /

Loop Powered Door Magnet

(ZTA-DH)

The loop powered door magnet is the latest


innovation from Zeta Alarm Systems. The
ZTA-DH is an addressable loop powered &
loop controlled door holder. It takes all its
power from the loop, so there is no need for a
separate power supply or battery.
The unit consists of a controller unit, which connects
directly to the loop, and a permanent magnet door
holder. The door holder controller can then be
programmed to operate in a similar manner to an Input/
Output unit.
The current consumption allows the use of up to 20 units
per loop.
It has a manual door release button to allow the magnet
to release the door at any time.
The interface also has a built in loop short circuit
isolator, to help maintain system integrity in the event
of a fault condition.

Loop In

Loop Out

4 Cores

Model

ZTA-DH

Part No.

83-005

Supply Voltage

17-33V DC

Standby Current

1mA Typ (Max 13.5mA)

Active Current

4mA Typ (Max 16.6mA)

Inputs

Manual door release button

Output

Release signal to magnet

Operating Temp.

0C to 60C

Holding Force

200 N

Magnet Release Pwr

3W

Size (interface)

127 x 88 x 59 mm

Weight (interface)

220g

Size (magnet)

85 x 110 x 38 mm

Weight (magnet)

400g

Size (keeper)

55 x 55 x 50 mm

Weight (keeper)

150g

35

Future Products
A showcase of forthcoming products in development:

Quatro 4 Loop Addressable


Fire Alarm Panel
Network capacity of 64 panels (254
loops)
Build-in European languages
Cutting edge cause & effect software
4 x 40 character display

EN54 Switched-Mode Power


Supplies
Complies with the latest requirements of
EN54 part 4
1.0 Amp output up to 12.0 Ah
5.0 Amp output up to 17.0 Ah

Xtratone Sounder and


Combined Sounder & Flasher
High dB output sounder
Low current consumption

36

Fyreye MKII Detectors


Built-in short circuit isolators
8 LEDs offering combination of flashing
modes
Introducing new protocol (backwards
compatible)
Special portable tool to check sensitivity
via built-in IR sensor

Detector Sounder Module


Plug and play sounder which fits onto
Fyreye Common Bases
Easily retrofitted to current installations
Up to 125 sounder modules can be
supported on a single loop

EN54 Certified Interface


Modules
Fully compliant & certified to EN54
Built-in isolators

37

Product Compatibility Chart

Premier AL 1-4

Max Per Loop:

Premier AL 5-8

Max Per Loop:

32

32

32

16

10

32

16

16

32

32

64

48

64

48

64

32

25

64

16

16

32

32

16

64

48

64

48

64

32

25

64

16

16

32

32

16

64

48

64

48

64

32

25

64

16

16

32

32

16

64

48

64

48

64

32

25

64

16

16

32

32

16

64

48

64

Key

48

64

32

25

64

16

16

32

32

16

64

48

About
Compatible, and can be connected directly to
the panel

38

ZTA-LE3

ZTA-LE2-10

ZTA-LE2

Max Per Loop:

Remote Led

ZTA-CSFIB

ZTA-CSB

FEA-RB

Premier AD

FEA-IB

FE-CB

ZTA-DH

Max Per Loop:

Detector Bases

ZTZM/4

ZTZM

ZSCC/4

Simplicity 126

ZSCC

ZIOU/230

ZIOU

Max Per Loop:

Addressable Interface

ZIU

ZAMTF/R

ZAMT/R

Simplicity 64

ZASF/RI

ZAS2/R(W)FI

ZAS2/R(W)

ZT-100RA

Addressable Sounder

ZT-50RA

Max Per loop:

WP-MCP/AD

ZT-CP2/AD

FEAOH2000

Alarm Manager

FEAHHE2000

REP-AL/G

FEAHE2000

REP-AL

Simplicity Micro

Addressable Detectors

FEAOE2000

REP-AD

Repeater Panels

Not compatible with the panel

Compatible, but requires some extra setup


programming

This chart is aimed to assist identifying which


devices or repeaters will work with each
control panel.
If you have any questions or doubts, contact your local
representative, or contact our technical support team
via email on technical@gltexports.com.

Device Current
Consumption
(in Micro-Amps)
Device

Quiescent

Alarm

FEAOE2000

480

2300

FEAHE2000

440

2400

FEAHHE2000

440

2400

FEAOH2000

520

2300

ZT-CP2/AD

1500

18000

WP-MCP/AD

1000

2900

ZT-50RA

5000

9000

ZT-100RA

5000

9000

ZAS2/R(W)

900

4000

ZAS2/R(W)FI

900

5500

ZASF/RI

900

2500

ZAMT/R

600

12000

ZAMTF/R

600

16000

ZIU

900

2900

ZIOU

900

10600

ZSCC

900

10600

ZSCC/4

900

42400

ZTZM

800

780

ZTZM/4

800

780

FE-CB

FEA-IB

43

6400

Cable Comparison
Type

Voltage drop (mV/A/m)

FDC 1.0

44

FDC 1.5

29

FDC 2.5

18

Voltage Drop Considerations


On an addressable system, loop voltage drop has to
be taken into consideration. Due to variations in load
distribution along the cable length, it is not always
practical to try to calculate the exact voltage drop.
The addressable devices are rated down to 17V, so every
point on the loop must be at least 17V at all times.
So when considering the question how long can my
loop be ?, the actual question to be answered is how
long can my loop be with my maximum alarm load, and
chosen cable thickness, before the loop voltage drops
below 17 V DC?. There is always the option to use a
thicker cable gauge.
The below tables give a rough indication of worst case
voltage drop for different loads and cable lengths for
the 3 main fireproof cable sizes.
Cable Length (1.0mm cable)
Load

100m

250m

500m

750m

1000m

1250m

1500m

1750m

2000m

100mA

26.56

25.9

24.8

23.7

22.6

21.5

20.4

19.3

18.2

200mA

26.12

24.8

22.6

20.4

18.2

16

13.8

11.6

9.4

300mA

25.68

23.7

20.4

17.1

13.8

10.5

7.2

3.9

0.6

FEA-RB

15000

ZTA-CSB

400

4000

ZTA-CSFIB

700

5500

ZTA-LE2

1500

10000

ZTA-LE2-10

1500

10000

Load

100m

250m

500m

750m

1000m

1250m

1500m

1750m

2000m

ZTA-LE3

10000

100mA

26.71

26.28

25.55

24.83

24.1

23.38

22.65

21.93

21.2

400mA

25.24

22.6

18.2

13.8

9.4

0.6

N/A

N/A

500mA

24.8

21.5

16

10.5

N/A

N/A

N/A

N/A

Cable Length (1.5mm cable)

200mA

26.42

25.55

24.1

22.65

21.2

19.75

18.3

16.85

15.4

300mA

26.13

24.83

22.65

20.48

18.3

16.13

13.95

11.78

9.6

400mA

25.84

24.1

21.2

18.3

15.4

12.5

9.6

6.7

3.8

500mA

25.55

23.38

19.75

16.13

12.5

8.88

5.25

1.63

N/A

Cable Length (2.5mm cable)


Load

100m

250m

500m

750m

1000m

1250m

1500m

1750m

2000m

100mA

26.82

26.55

26.1

25.65

25.2

24.75

24.3

23.85

23.4

200mA

26.64

26.1

25.2

24.3

23.4

22.5

21.6

20.7

19.8

300mA

26.46

25.65

24.3

22.95

21.6

20.25

18.9

17.55

16.2

400mA

26.28

25.2

23.4

21.6

19.8

18

16.2

14.4

12.6

500mA

26.1

24.75

22.5

20.25

18

15.75

13.5

11.25

39

Notes

40

41

42

Available now from:

Tel: +44 (0) 1792 455 175


Fax: +44 (0) 1792 455 176
E-mail: info@zetaalarmsystems.com
Web: www.zetaalarmsystems.com

Detection House
72-78 Morfa Road
Swansea
SA1 2EN
United Kingdom