The ACI Communications MultiFlex Amplifier is specifically designed for use in vertical
mount applications. It is ideal for apartment complexes or business high-rise situations.
Page 1 of 6
www.acicomms.com
Page 2 of 6
www.acicomms.com
Reverse Gain
19 or 24 dB
-20 dB
Test Point
Forward Input
Reverse Output
EQ
EQ
1
Pad
Pad
LPF
Net
Board
Pad
EQ
-20 dB
Test Point
Notes
1. Forward gain stated at 750, 870 or 900 MHz. Reverse gain stated at 40 MHz.
-20 dB
Test Point
Pad
-20 dB
Test Point
Forward Output
Reverse Input
Forward Gain
37 dB @ 750 MHz
40 or 37 dB @ 870 MHz
40 or 37 dB @ 900 MHz
Notes
Part Number
Bandwidth (MHz)
2, 3
Station flatness
Gain (dB)
Slope (dB)
750
870
870
37.0
37.0
40.0
Hybrid Return
900
900
37.0
40.0
RTA24HY-065
0.5
0.5
0 1.0
RTA30HY-065
See notes
19.0
24.0
0 1
16.0
16.0
-20.0 1.0
-20.0 1.0
79
41/51
35
67.0
68.0
68.0
67.0
67.0
80.0
68.0
79.0
79.0
75.0
75.0
79.0
61.0
67.0
67.0
62.0
62.0
72.0
8.5
8.5
8.5
8.5
8.5
9.0
Channel loading
10.0 1.0
10
30.0
10
36.0
11
24.1 (Max)
25.1 (Max)
40-90
Units
@ 40 VAC
0.82
@ 50 VAC
0.68
@ 60 VAC
0.57
@ 70 VAC
0.50
@ 80 VAC
0.45
@ 90 VAC
0.40
10
PHYSICAL
Dimensions (L X W X H)
in (cm)
Weight
lbs (kg)
7.9 (3.58)
Notes
1. "_ _ _" In part number is for frequency split, reverse and power cord set options.
2. Maximum bandwidth freqency depends on the reverse frequency split.
3. Lower bandwidth frequency of chosen split.
4. Single station measured with all forward and reverse pads and equalizers with 0 dB values.
5. Typical operating gain is measured with equalizers in all forward locations and 0 dB pads.
6. Standard channels flat per NCTA test methods, or sloped as indicated by rated output slope.
7. Worst case as measured on matrix distortion analyzer utilizing CW carrier.
8. Worst case as measured on matrix distortion analyzer utilizing a 15.75 KHz square wave and measured to nearest dB.
9. Single station measured with 0 dB pads and equalizers . For system calculations add 1 dB for equalizer loss and 1 dB loss for diplex
filters and test points.
10. Worst case group delay measurements are for 42/53 subsplit only, for different splits contact ACI.
11. 6 KV surge protection standard for line powered units. For cable powered units, 6 KV surge protection requires installation of the
optional plug-in sidactor (P/N 090491).
12. 550 MHz analog channel loading, 79 channels +200 MHz for 750 MHz, +320 MHz for 870 MHz, +350 MHz for 900 MHz,
digital channel loading, 256 QAM at -6 dBc relative to its associated visual carrier
Confidential
Information contained in this document is subject to change without notice
Revision date: 1/13/2009
Page 3 of 6
www.acicomms.com
Page 4 of 6
www.acicomms.com
Required Accessories
The following accessories are required for operation.
Forward all units - reverse if active
Plug-in equalizers
Plug-in pad
TYPE
PART NUMBER
1 Forward
1 Forward
1 Reverse
1 Reverse
RANGE (dB)
INCREMENTS (dB)
1.5
Forward
CEQ750/XX
1.5 to 21.0
Forward
CEQ870/XX
1.5 to 21.0
1.5
Forward
EQDA750/XX
0 to 25.5
1.5
Forward
EQDA870/XX
0 to 21.0
1.5
Reverse
REQ42/XXB
0 to 12.0
1.5
Reverse
EQDA55/XX
0 to 12.0
1.0
Reverse
REQ65/XXB
0 to 12.0
1.0
NOTE: For 900 MHz stations use the 870 MHz forward equalizers
Attenuator Pads
Attenuators with short handles (SXPXXT) from 0 to 20.0 in 0.5 dB increments
Attenuators with long handles (SXLXX) from 0 to 20.0 in 0.5 dB increments
Ordering Information
The MultiFlex can be ordered in a number of variations.
Each is defined by a part number which specifies a certain combination of options.
Page 5 of 6
www.acicomms.com
Order Date:
ORDERING MATRIX
Position
PART NUMBER
1-2-3
MODEL
MFT = MultiFlex Amplifier
BANDWIDTH
7 = 750 MHz
8 = 870 MHz
9 = 900 MHz
11
12
13
14
15
12
REVERSE GAIN
1 = Passive reverse (Jumper)
6 = Hybrid reverse (19 dB gain)
7 = Hybrid reverse (24 dB gain) (see note 3)
13
POWERING
1 = Cable switch mode power supply
(40 - 90 VAC)
9 = Mains switch mode power supply
(90 - 240 VAC)
15
FORWARD GAIN
37 @ 750, 870 or 900 MHz
40 @ 870, or 900 MHz
HYBRID TECHNOLOGY
P = GasFet Power Doubling
10
--
6-7
10-11
FREQUENCY SPLIT
(Reverse / Forward - MHz)
S4 = Subsplit (42 / 53)
S5 = Subsplit (55 / 70)
S6 = Subsplit (65 / 85)
S7 = Subsplit (40 / 50) (see note 2)
NOTES:
1. For proper setup, due to 1002 MHz platform, use only an ACI Communications test probe. (P/N 100685-01)
2. For S7 frequency split (40 / 50) use REQ42/XXB for reverse EQ.
3. 24 dB reverse gain is not currently available on the 55/ 70 frequency split configuration.
4. Contact ACI for distortion specifications other than standard 0 dB of slope.
5. Positions 14 & 15 are not used in the cable powered (40 - 90 VAC) part number.
ACCESSORIES:
Required Accessories
Forward all units - reverse if active
Plug-in equalizers
1 Reverse
Plug-in pad
1 Reverse
1 Forward
1 Forward
RevAE 11-10-2009