CAM OPERATED ROTARY SWITCHES

CAM OPERATED ROTARY SWITCHES

NOTES

CONTENTS
Page no

32

Introduction

General Construction

Technical Specification

Isolators/on-off Switches

Changeover Programmes with off

Changeover Programmes without off

Multistep Switches with off

Multistep Switches without off

Instrumentation Switches

10

Motor Control Switches

12

Gang Switches

14

Control Switches

15

Mounting Dimensional Drawings

16

Knobs / Handle

20

Front Plate Data

22

Customised Programme Formation

23

Ordering Information

25

Breaker Control Switches

26

Installation Procedure

29

DC Switches

30

CAM OPERATED ROTARY SWITCHES

CAM OPERATED ROTARY SWITCHES

GENERAL CONSTRUCTION-S,TP & RT SERIES

DC SWITCHES
Features

Option of 60 & 90 degree switching


programmes.

Snap Action rugged mechanism

Quick-make, Quick-Break operation

Applications;

Double break contacts are of Agcdo


housed in glass filled polymied contact
stage to ensure optimum electrical
condition & weldfree operations.

DC power circuits

UPS & Inverter power switching

All switching programmes- Isolators,


Changeovers & Multistep switches.

Cam operated switching for higher


electrical endurance & smooth
operations.

D16 D63

Custom built switching application with


90 degree switching angle.

3 to 5
Panel gap

Drilling plan

B3

B2
D

SQ F

CAM ASSEMBLY

TYPE
D16
D25/32
D40/63

Stages
D16
D25/32
D40/63

Length in
mm

Salzer switches S, TP & RT series are designed to accomodate two isolated Double break silver alloy contacts per stage at 180 degree
disposition. AC Switches are characterised by Quick make-slow break action by the inbuilt feature in our latching device and cam
construction, these switches can be applied for DC Switching also by Derating and by adding additional contacts in series according to the
DC Switching voltage.

SQ B1

B1
48
48
68

B2
12
12
15

B3
5.5
5.5
5.5

D
50
50
70

CONTACT ASSEMBLY

F
64
64
64

S
12
15
21

10

11

12

62
65
69

74
80
90

86
95
111

98
110
132

110
125
153

122
140
174

134
155
195

146
170
216

158
185
237

170
200
258

182
215
279

194
230
300

Contacts

: Double break Type AgCdO

Insulation : Glass Filled polyamide with High Tracking Index

S SERIES
STANDARD

Operating Temp

: -25OC to 55oC

Operating Frequency

: Upto 10KHz

Humidity 95% Rh

: 48 hours

TP SERIES
TOUCH PROOF

RT SERIES
REAR TERMINATION

TECHNICAL SPECIFICATION
DC
RATINGS

DESCRIPTION

Rated Uninterrupted Current [Ith]


DC 22A L/R 2m sec
Rated
Operational
110V
Voltage
No of series
contacts
DC 23A L/R 7.5m sec
Rated
Operational
24V
Voltage
No of series
contacts
AC
RATINGS

GENERAL

250V

460V

D16

D25

D32

D40

D63

20

32

40

50

80

16

25

32

40

63

* Available from 6 to 400 Ampere

* Available from 6 to 16 Ampere

* Available from 16 to 63 Ampere

* Open Terminals for easy Accessibility

* Touch Proof (Finger Protected)


Terminals (IP20)

* Rear Facing Terminals for convenient


Access
* Touch Proof (Finger Protected)
Terminals (IP20)

48V

70V

110V

180V

250V
A

10

16

25

32

40

6
7

10

14

20

25

16

25

32

40

63

Fuse Protection

16

25

32

40

63

Short Circuit through fault current

kA

10

10

20

20

mm2

1.5

1.5

1.5

1.5

1.5

mm2

10

16

Nm

0.8

1.2

1.2

16

10

10

Terminal
Cross Section
Maximum Contact Stages

380-440V

[Rigid] min
[Flex]

max

AC Duty Rating
Category

Hp

AC3 Rating 3 Phase


AC21 Rating

Tightening Torque

30

RATED OPERATIONAL CURRENT Ie


SWITCH TYPE

UNIT

DC Duty Rating
Typical AC Application

Category

Typical DC Application

AC-1

Non-Inductive or slightly Inductive Loads,


Resistance furnaces.

DC-1

Non-Inductive or slightly Inductive Loads,


Resistance furnaces.

AC-3

Squirrel-cage motors : starting switching


Off motors during Running.

DC-22

Switching of resistive loads, Including


moderate overloads

Control of AC electromagnetic loads

DC-13

Control of DC electromagnets

AC-21A

AC-15

Switching of resistive loads, Including


moderate overloads (frequent switching)

DC-23

Switching of motor loads or other


highly inductive loads

AC-23-A

Switching of motor loads or other highly


inductive loads (frequent switching)

----

-----

CAM OPERATED ROTARY SWITCHES

CAM OPERATED ROTARY SWITCHES

ISOLATORS-ON/OFF SWITCHES

BREAKER CONTROL SWITCHES

ISOLATORS:
Isolators which are ON/ OFF switches are used for making/breaking
electrical circuits for isolation purpose. In rotary switches isolators
are offered in very compact versions from 1 pole to 12 pole for
multiple circuit isolation. The duty category utilisation of the isolators
are categorized as AC1/AC21 for higher duty like motor duty operation
the rating AC3/AC23 should be considered
Isolators can be offered with stayput /spring return and preclose
contacts for neutral & earth closing applications.

BREAKER CONTROL ORDERING CODE

Example:-

10

Application: Isolation of Main,Control & Instrumentation circuits also


for motor ON / OFF & Machine tool main incomer isolation

CONNECTING DIAGRAM
25 Ampere Spring return TNC with 1 set of Main Contact 1NO+1NC,
1 LMD contact in Trip position & 1 LMD contact in Close position with
Sequential locking and Barrell Lock Mounting

11 13 15

17 19 21

10 12 14 16 18

20 22

23

24

1 to 12 pole
Digit 1

Digit 5

No of Main Contacts in Trip /


Close Position
Description
Code
1 NO+1 NC
1
2 NO+2 NC
2
3 NO+3 NC
3
4 NO+4 NC
4
5 NO+5 NC
5
6 NO+6 NC
6
7 NO+7 NC
7
8 NO+8 NC
8
9 NO+9 NC
9

Digit 2
Sequence Locking
If required
Not required

Code
Q
O

Digit 3
Latching Mechanism
Spring Return
Stayput

Code
S
C

STAYPUT

No of LMD Contacts in Trip Position


Description
Code
1 Contact
1
2 Contact
2
3 Contact
3
4 Contact
4
5 Contact
5
6 Contact
6
If not required
0

Digit 6
No of LMD Contacts
Position
Description
1 Contact
2 Contact
3 Contact
4 Contact
5 Contact
6 Contact
If not required

in Close
Code
1
2
3
4
5
6
0

60 Degree

90 Degree

Description

Programme Code

Programme Code

Programme Code

No of Stage

1 Pole
2 Pole
3 Pole
4 Pole
5 Pole
6 Pole
7 Pole
8 Pole
9 Pole
10 Pole
11 Pole
12 Pole

61001
61002
61003
61004
61005
61006
61007
61008
61009
61010
61011
61012

61191
61192
61199
61194
61906
-

61195
61198
61197
61196
-

1
1
2
2
3
3
4
4
5
5
6
6

Script Plate
Marking

Feasible Ampere. Rating : 6,10,16,25,32,40,63,80,100,125,200 & 400 Amps

ISOLATORS WITH PRECLOSE CONTACT

Digit 7

90 Degree
Ampere Rating
25 Ampere
32 Ampere

Digit 4
LMD Contacts
If required
Not required

Code
L
D

10

4 to 5 pole
Description

28

SPRING RETURN ISOLATORS 45 Degree


45 Degree Spring Return to OFF

Code
E
F

Digit 8, 9, 10
Mounting
Standard Front Mounting
Barrei Lock with Centre
Key

90 Degree Complete Rotation

Code
B03
B90

Programme code

61194
No of
Stage
2
2
3
2

4 Pole - 1 Pole Preclose


61194
4 Pole - 3 Pole Preclose
61904
5 Pole - 3 Pole Preclose
61905
3 Pole with Neutral Terminal
61178
Feasible Ampere. Rating :
6,10,16,25,32,40,63,80,100,125,200 & 400 Amps

1 to 4 pole
Description

Programme code

1 Pole Spring Return


61351
2 Pole Spring Return
61352
3 Pole Spring Return
61353
4 Pole Spring Return
61354
Feasible Ampere. Rating :
6,10,16,25,32,40 & 63 Amps

No of
Stage
1
1
2
2

CAM OPERATED ROTARY SWITCHES

CAM OPERATED ROTARY SWITCHES

CHANGEOVER PROGRAMMES WITHOUT OFF

BREAKER CONTROL SWITCHES


FEATURES

OPERATIONS

Specially designed spring return


mechanism for reliable operation.

Robust handle design for better grip


and operating leverage.

Facility to add on multiple contacts in


LMD operations.

Possibility of adding upto 9 main contacts


for trip / close operations.

Main contact operations


Breaker control switches have 3 operating
positions viz., Trip, Neutral & Close either in
stayput or in spring return mechanism. In
spring return mechanism handle returns to
neutral position after trip / close operation.
Main contacts operates in trip or in close
positions according to the operation of the
switch.

CONNECTING DIAGRAM
A1

B1
C1
D1
E1 F1
F1
H1
J1
K1
L1
M1
A2 B2
C2
D2
E2 F2
F2
H2
J2
K2
L2
M2

2 4

Without Jumper
6 8
10 12 14 16

1 3

5 7

1 to 12 pole

9 11

13 15

1 to 4 Pole

LMD operations

DESCRIPTION

UNIT

Rated Operational voltage

Ue

Resistance to surge voltage


Rated uninterrupted current
Rated Operational Current
Pilot Duty AC15

Uimp
Ith
Ie
20-240V AC
380-440V AC

Short circuit protection


HRC fuse size
Rated short circuit
Terminal cross section
Rigid wire

min
max
min
max

Flexible wire
Terminal Screw
Terminal Tightening Torque
CSA / UL RATINGS
Voltage Rating
Ampere Rating

V ac
V dc
kV
A

SG25
690
250
6
32

SG32
690
250
6
40

A
A

8
5

14
6

25

32

kA

10

10

1.5
4
1
2.5
M4
1.2Nm

2.5
6
1.5
4
M4
1.2Nm

mm2
mm2

V
A

VA Rating

LMD contacts can either be fitted in trip or


in close position. When the switch makes
closing operation the LMD contacts fitted in
the closing position will close and stays in
that position even after the switch handle
goes back to neutral position. Similarly the
LMD contacts fitted in the trip position
remains in that position when the switch
handle makes trip operation and goes back
to neutral position.These LMD contacts
generally used for annunciation purpose
thus helps the user to indicate triping of
breaker due to fault conditions and help in
diagonising the feeder fault problems.

50 V

125 V

250 V

26

1
2
3
1
2
3
1
2
3

Resistive
Amps
20
3
20
1.0
5
20

90 Degree Complete Rotation

1
2
3
4

This device fitted along with this breaker


control switch will act as a blocking device
for consecutive closing of the switch, will
prevent closing coil of the breaker getting
charged repeatedly and hence eliminates
burning of this closing coil.

60 Degree

No of
Stage
5
6
7
8
9
10
11
12

No of
Description
Programme code
Stage
61037
1
5 pole
61041
61038
2
6 pole
61042
61039
3
61043
7 pole
61040
4
8 pole
61044
--9 pole
61045
--61046
10 pole
--11 pole
61047
--12 pole
61048
Feasible Ampere Rating Applicable : 6,10,16,25,32,40,63,80,100,125,200 & 400 Amps

Description

SIL Operations

Programme code

pole
pole
pole
pole
-----

SPRING RETURN
45 Degree Spring Return

TECHNICAL SPECIFICATION
GENERAL :-

Description

ENDURANCE

Electrical * - 10,000 Operations at 120


cycles/ hour

600
20

600
30
AC-720 VA
DC-275 VA

Operational Temperature :-250 C to 550 C

Programme code

1 pole
61371
2 pole
61372
3 pole
61373
Feasible Ampere Rating: 6,10,16,25,32,40 & 63 Amps

Mechanical * - 1 Lac Operations at 300


cycles /hour

No of
Stage
1
2
3

WITHOUT JUMPER
45 Degree Spring return without Jumper

90 Degree Stayput without Jumper

Frequency up to 5 KHz

SG 25
No of
Voltage Contacts in
series

STAYPUT

SG 32

Inductive L / R Amps
10
m sec

20
m sec

40
m sec

20
2.5
15
20
0.5
2
10

15
20
1.5
10
20
0.3
1.0
4

6
14
20
1.0
5
10
0.2
0.5
1

Resistive
Amps
25
5
25
1.2
6
25

Inductive L / R Amps
10
m sec

20
m sec

40
m sec

25
3
18
25
0.6
2.5
12

18
25
2
12
25
0.4
1.2
5

8
18
25
1.2
6
12
0.3
0.6
1.2

Description
1
2
3
4

pole
pole
pole
pole

without
without
without
without

Programme code

jumper
jumper
jumper
jumper
Feasible Ampere Rating
6,10,16,25,32,40,63,80,100,125,200

61637
61638
61639
61640
:
& 400 Amps

No of
Stage
1
2
3
4

Description

Programme code

1 pole without jumper


Feasible Ampere Rating :
6,10,16,25,40 & 63 Amps

61771
-

CAM OPERATED ROTARY SWITCHES

CAM OPERATED ROTARY SWITCHES

MULTISTEP (POLE-WAY) SWITCHES WITHOUT OFF

CUSTOMISED PROGRAMME FORMATION


The switch design and construction gives flexibility for making
customised programmes within a very short period. Basically an
engineer trying to specify the customised programme should
concentrate on the following points.
(a) Number of Operating positions of switch handle
(b) Total number of Contacts required
(c) Contact closing sequence of all the contacts required in various
positions of handle. Please Note :(d) Each position should be identified and Script plate marking required
in those postions should be mentioned .
(e) The latching angle (angle between positons) Standard latching /
switching angles are 600, 900, 450 & 300 .Spring return are also
possible for 450 & 900 switching angle.

( f ) Total number of contacts can be decided based on the actual


need. You may arrange the contacts to your convenience and
number them as 1/2, 3/4, 5/6...etc.. While making the switch, we
may rearrange the contacts to use solid jumpers so as to avoid
loose wire jumpers
(g) Fill up the Programme sheet by marking X at places where contacts have to Close ( NC ).
Also Ensure to specify the Ampere Rating, Mounting Style, Switching
angle, Script Plate markings ,Terminal marking, Lockable Position
(If any)
For example refer the sample Customised programme sheet of a
Bedroom switch having 3 contacts controlling a Tube,Fan & Night
lamp

Note:-The above Construction carries a five digit number starting with


( 7xxxx ) alloted by us .This Number alone is sufficent for future
correspondance & further Ordering

Switch Positions

PROG
NO.

DESCRIPTION

61049

1 Pole-3 Way

61069

2 Pole-3 Way

61089

3 Pole-3 Way

61120

4 Pole-3 Way

61124

5 Pole-3 Way

61126

6 Pole-3 Way

61050

1 Pole-4 Way

61070

2 Pole-4 Way

61090

3 Pole-4 Way

61121

4 Pole-4 Way

61051

1 Pole-5 Way

61071

2 Pole-5 Way

61091

3 Pole-5 Way

61122

4 Pole-5 Way

61052

1 Pole-6 Way

61072

2 Pole-6 Way

61092

3 Pole-6 Way

61053

1 Pole-7 Way

61073

2 Pole-7 Way

61093

3 Pole-7 Way

61054

1 Pole-8 Way

61074

2 Pole-8 Way

61094

3 Pole-8 Way

61055

1 Pole-9 Way

61056

SCRIPT PLATE MARKING

CONNECTING DIAGRAM /
TERMINAL MARKING

NO OF
STAGES

5
3 WAY - 600

6
8
1 to 6 pole

9
2
4

4 WAY - 900

6
1 to 4 pole

8
3
5

5 WAY - 600

8
1 to 4 pole

10
3

6 WAY - 60

1 to 3 pole

9
4
7

7 WAY - 450
1 to 3 pole

11
4
8

8 WAY - 450
1 to 3 pole

12

9 WAY - 300

1 Pole-10 Way

10 WAY - 300

61057

1 Pole-11 Way

11 WAY - 300

61058

1 Pole-12 Way

12 WAY - 300

NIGHT LAMP

MULTISTEP SWITCHES WITHOUT JUMPER

61649

1 Pole-3 Way
Without Off
Without Jumper

61650

1 Pole-4 Way
Without Off
Without Jumper

61670

2 Pole-4 Way
Without Off
Without Jumper

4 WAY - 900

2
4 WAY - 900
4
1 to 2 pole

Feasible Ampere Ratings: 6,10,16,25,32,40,63,80,100,125 & 200 Amps

24

CAM OPERATED ROTARY SWITCHES

CAM OPERATED ROTARY SWITCHES


FRONT PLATES
STANDARD
STYLE

INSTRUMENTATION SWITCHES
BIGGER
STYLE

FRAME SIZE

S6/S10
TP6/TP10

AMMETER SELECTOR SWITCHES

ACCESSORIES

--

SHROUDING COVERS

PROG
NO.

DESCRIPTION

CONNECTING DIAGRAM /
TERMINAL MARKING

61325

1 Pole-3
Transformer
With OFF

61321

1 Pole-1
Transformer

SCRIPT PLATE MARKING

NO OF
STAGES

Rectangular

S16
TP16
RT16

S6/S10
TP6/TP10
61331

1 Pole-2
Transformer

TYPE
S25/S32
RT25/RT32

S40 & Above

S63
S200

--

61384

1 Pole-3
Transformer
Without OFF

61326

1 Pole-4
Transformer
With OFF

61327

2 Pole-2
Transformer
W3ith OFF

61328

3 Pole-3
Transformer
With OFF

61329

3 Pole-3
Transformer
Without OFF

61330

4 Pole-4
Transformer
Without OFF

71000

Direct Ammeter
Selector
Without Current
Transformer

S16
TP16
RT16

S25/S32
RT25/RT32

175
210
175
210

115
200
110
200

100
90
115
100

NO. OF
STAGES
3
3
3
3

S40 & Above


S-Series

SPECIAL FRONT PLATES


48 x 60

S16
TP16
RT16

--

64 x 80
D

S25/S32
RT25/RT32

S16
TP16
RT16

TYPE

S25/S32
S63

65+0.2
89+0.2

H
2 STAGE
48
118

3 STAGE
63
182

POWER FACTOR METER SWITCHES


One Current
Transformer

* Other special size mounting plates at Front or Rear can be


supplied against requirement.

73078

2
One Voltage
Transformer

Two Current
Transformer
CODE - YR

CODE - GB

CODE - BB

CODE - AB

WATTMETER SWITCH
73071
Yellow Front Plate
Red Knob

22

Grey Front Plate


Black Knob

Black Front Plate


Black Knob

Aluminium Foil with


Black Knob

Two Wattmeter
Method

3 WAY- 900
:

Feasible Ampere Rating: 10 & 16

11

CAM OPERATED ROTARY SWITCHES

CAM OPERATED ROTARY SWITCHES


KNOBS / HANDLE

MOTOR CONTROL SWITCHES


MOTOR SWITCHES / MULTI SPEED SWITCHES
KNOBS/HANDLE COLOURS

PROG
NO.

DESCRIPTION

61212

2 Speed
Single Winding

61213

2 Speed
Single Winding

61215

2 Speed
Single Winding
For use with
Contactors

61217

2 Speed
Single Winding
Reversing

61219

2 Speed
2 Seperate
Windings

61226

3 Speed
2 Windings
(O-A-B-A)

61243

3 Speed
2 Windings
(O-A-B-B)

RED

SCRIPT PLATE MARKING

CONNECTING DIAGRAM/
TERMINAL MARKING

NO OF
STAGES

BLACK

TD - TEAR DROP

CODE - TD
S6/S10/TP6/TP10
S16/TP16/RT16
S25/S32/RT25/RT32
S40 & ABOVE

FL - FLAG KNOB

27
27
36
50

41
41
52
70

25
25
31
42

21
21
25
33

CODE - FL
S6/S10/TP6/TP10
S16/TP16/RT16
S25/S32/RT25/RT32
S40 & ABOVE

16.5
27
36
50

22
39
50
68

13.75
24
27
42.5

18
24
25
32

Feasible Ampere Rating : 6,10,16,25,32,40 & 63 Amps

PG - PISTOL GRIP HANDLE

BG - BALL GRIP HANDLE

LV - LEVER HANDLE
MOTOR SWITCHES - START & RUN SWITCHES
PROG
NO.

DESCRIPTION

SCRIPT PLATE MARKING

CONNECTING DIAGRAM/
TERMINAL MARKING

NO OF
STAGES

90

Spring return from start to 0


61208

Split-phase Start

Spring return from start

CODE - PG
Applicable for
S16 / TP16 / RT16
S25 / S32 / RT25 / RT32
S40 / S63

20

CODE - BG
Applicable for
S16 / TP16 / RT16
S25 / S32 / RT25 / RT32
S40 / S63

CODE - LV
Applicable for
S80 / S100 / S125
S200 / S400

61209

Split-phase Start
Reversing

61270

Split-phase Start
Reversing
Switching

Feasible Ampere Rating : 6,10 & 16 Amps

13

CAM OPERATED ROTARY SWITCHES

CAM OPERATED ROTARY SWITCHES


ENCLOSURE MOUNTINGS

CONTROL SWITCHES

Features : - * Switches Mounted in ABS Plastic Enclosure * Provides protection from dust & hazardous material * with Round Padlockable
Device * Secure with max 3 Padlocks in OFF position * Prevents operational access to Unauthorised Personnel * Suitable for 900 switches.

CONTROL SWITCHES:
Control switches are used to energise contactors for controlling motor operations. Most of the switches are of Spring return type to enable
latching of the circuit with Contactors NO contact to facilitate tripping by Contactors Tripping device.

Applications: Control switches are a unique alternative for many of the Push Button stations, where it is preferred to control a system with
one switch instead of many Push Buttons. Many positions of the switch are possible to derive combinations.
PROG
NO.

DESCRIPTION

61300

1 Pole STOP-START
With Spring Return

61388

2 Pole STOP-START
With Spring Return

SCRIPT PLATE MARKING

CONNECTING DIAGRAM/
TERMINAL MARKING

NO OF
STAGES
1

spring return

B 31

TYPE
S16/TP16/RT16
S25/S32/RT25/RT32
S40/S63/RT40/RT63

42
42
48

110
125
175

80
100
125

66
70
90

60 90
80 115
105 155

STAGES
3
2
2

Features : - * Switches Mounted in sheet metal enclosures *Provides protection from dust & hazardous enviorement. *Knob / Handle
operatable * Suitable for switches upto 32 Ampere

61301
61701
61307

1 Pole STOP-START
With Spring Return
From START to RUN
Without Jumper
STOP-START SWITCH
With Spring Return
to run for 2 units

61707

Without Jumper

61366

Contactor Control
With Spring Return
to OFF

spring
return from
start to 1

spring return
from start

spring
return to 0
61271

M 17

TYPE
S6/S10/TP6/TP10
S16/TP16/RT16
S25/S32/RT25/RT32
16 Ampere For/ Reverse

A1

A2

A3

D1

D2

D3

70
70
70
81

60
60
60
65

4
4
4
5

85
85
85
75

89
89
89
75

98
98
98
110

MAX
4
4
3
-

Features : - * Four hole base mounted on Rear side of the Panel * Knob/ Handle operatable

Length L = No of Stages x S + W

*Quote B12 for next Bigger size Front plate

B 02 * IP 55 Protection from front


TYPE

S6/S10/TP6/TP10
S16/TP16/RT16
S25/S32/RT25/RT32
S40/S63/RT40/RT63
S80/S100/S125
S200
S400

18

A1

A2

B1

B2

B3

MAX

36
48
48
68
81
81
81

M5
M5
M5
M6
M6
M6
M6

36
36
48
68
68
68
68

9
12
12
15
15
15
15

4.5
4.5
4.5
5.5
5.5
5.5
5.5

48
60
60
84
101
101
101

32
48
64
88
88
88
88

4.5
3.5
3.5
5
5
5
8

9.5
12
15
21
26
32
64

22
30
31
41
48
48
48

10
12
8
6
6
6
3

Motor Voltage
Control Switch

Feasible Ampere Rating : 6,10,16,25,32,40 & 63

MOUNTING FEASIBILITY TABLE


Mounting
Code
B00
B02
B03
B12
B13
B14
B19
B21
B30
B32
B33
B34
B41
B42
B51
B53
B63
B90
F32
F41
F47
M17
A17
B17
B31

Description
Front Mounting S25/S32 Switches with 48x48 plate
Rear/Back Mounting with Standard Front Plate
Front Mounting, Standard Mounting Plate
Rear/Back Mounting with next size plate
Front Mounting with next size plate
Single Hole Mounting 48x48 plate for S6 to S32
Single Hole Mounting 32x32 plate for S6 & S10
Din Rail Mounting on 35 mm Rail
Front Mounting with Rectangular padlock
Rear/Back Mounting, Door Interlock + Rectangular Padlock (B42+B30)
Front Mounting with Round padlock
Rear Mounting, Door Interlock + Round Padlock (B33+B42)
Rear Mounting with Door Clutch Mechanism (Door Opens in both pos)
Rear Mounting with Door Interlock
Single Hole Mounting, Key operated without Front Plate
Single Hole Mounting, Key operated with Front Plate
Front Mounting, Knob/handle Operatable, Lockable with Key
Front Mounting with Centre Key Lock
Door Clutch + Rectangular Padlock Mounting Plate at Front
Door Clutch without Padlock, Mounting Plate at Front
Door Clutch, Front Plate of Next size, Mounting Plate at Front
SS Enclosure
Max stages
Aluminium Enclosure
Max stages
PVC/ABS Enclosure
Max stages
PVC/ABS Enclosure with Round Padlock
Max stages

S6/10

S16

Feasibility -
S25/32 S40/63 S80/100/125

S200/400

Upto 4 Upto 4 Upto 3


Upto 4 Upto 3 Upto 2
Upto 4 Upto 4 Upto 4
Upto 3 Upto 2 Upto 2

15

CAM OPERATED ROTARY SWITCHES

CAM OPERATED ROTARY SWITCHES

LOCKABLE SWITCHES

FRONT MOUNTINGS
Features : * Standard 4 hole Front panel Mounting * Knob / Handle operatable * Suitable for all switching angles & Spring return switches *
Front Assembly in 4 different colors Yellow/Red, Grey/Black, Black/Black, Aluminum Finish.
3 to 5
Panel gap

Drilling plan

B3

Features : - * Four Hole Round padlockable mounting * Secure with max. 3 padlocks in OFF position. prevents operational access to
unauthorised personnel.* Suitable for switches only with 900 Switching angle

Drilling plan
6/10 Amps only

B2

3
QB

QD

SQF

2
B

B1

SQ B1

Length L = No of Stages x S + W

Length L = No of Stages of Prog x S + W

B 33 * IP 55 Protection from front

*Quote B13 for next Bigger size Front plate

B03 *IP 55 Protection from front

TYPE
TYPE
S6/S10/TP6/TP10
S16/TP16/RT16
S25/S32/RT25/RT32
S40/S63/RT40/RT63
S80/S100/S125
S200
S400

B1

B2

B3

20
36
48
68
68
68
68

9
12
12
15
15
15
15

4.5
4.5
5.5
5.5
5.5
5.5
5.5

24
29
36
46
46
46
46

33
46
52
76
92
88
88

32
48
64
88
88
88
88

9.5 18.5
12
26
15
27
21
33
26
40
32
40
64
40

MAX
12
21
15
10
10
10
4

S16/TP16/RT16
S25/S32/RT25/RT32
S40/S63/RT40/RT63
S80/S100/S125
S200
S400

B1

B2

B3

MAX

36
36
68
68
68
68

12
12
15
15
15
15

4.5
4.5
5.5
5.5
5.5
5.5

46
52
76
92
88
88

65
65
95
95
95
95

26
26
31
31
31
31

12
15
21
26
32
64

26
27
33
40
40
40

12
8
6
6
6
3

Features : - * Four Hole Rectangular Padlockable mounting * Secure with max four padlocks in OFF position.* Prevents Operational Acess
to Unauthorised Personnel * Suitable for switches with 900 Switching angle .

Features : - * Single hole mounting with std dia 22.5 mm * Eleminates the need for screws / Hardware for panel fixing * Easy Termination *
Suitable upto 32 Ampere
Locking lever
3

13

3 Max.
Panel gap

Length L = No of Stages x S + W

23

B 30 * IP 55 Protection from front

Length L = No of Stages x S + W

*Quote B14 for next Bigger size Front plate

B14/B19 *IP 65 Protection from front

TYPE
S6/S10/TP6/TP10
S16/TP16/RT16
S25/S32/RT25/RT32

CODE

B19
B14
B19
B19

33
33
46
52

32
48
48
48

9.5
9.5
12
15

10
13
13
13

28.5
28.5
36
37

MA-X
12
12
21
15

Features : - * Key Operated safety switch, prevents operational access to unauthorised personnel., * Available with or without Front plate
* Suitable up to 32 Ampere.
Length L = No of Stages x S + W

3 to 5
Panel gap

B1

B2

F1

F2

F3

MAX

S16/TP16/RT16
S25/S32/RT25/RT32
S40/S63/RT40/RT63
S80/S100/S125
S200
S400

48
48
68
68
68
68

12
12
15
15
15
15

46
52
76
92
88
88

75
75
98
98
98
98

102
102
126
126
126
126

13.5
13.5
16
16
16
16

23
23
25
255
25
25

12
15
21
26
32
64

26
27
33
40
40
40

12
8
6
6
6
2

Features : - * Knob / handle operatable Switch * With Key lockable Assembly prevents switching by unauthorised personnel. *Key lock / Key
removable only in OFF position * Lock Assembly can also be provided on top

Drilling plan

B3

B2

TYPE

B1

FRONT PLATE

*for Handles key arrangement comes on top


B53/B51 * IP 40 Protection from front

*Quote B51 for Mounting without Front plate


TYPE
S16/TP16/RT16
S25/S32/RT25/RT32

16

B 63 * IP 40 Protection from front

B1

B2

B3

MAX

23
23

13.5
13.5

2.5
2.5

46
52

28
28

12
15

37
38

5
5

TYPE
S16/TP16/RT16
S25/S32/RT25/RT32
S40/S63/RT40/RT63

Length L = No of Stages x S + W

B2

B4

B5

MAX

15
15
15

23
23
23

43.5
43.5
43.5

46
52
76

64
64
64

12
15
21

45
45
47

12
12
6

17

CAM OPERATED ROTARY SWITCHES

CAM OPERATED ROTARY SWITCHES


GANG SWITCHES

REAR MOUNTINGS

GANG SWITCHES:

Features : * Snap mounting base on Din EN50022 ( Omega) rail 35mm & 1.2 mm thick * or Two Hole rear mounting.* Provides Easy Termination

These switches are called Gang switches, as they increase the capacity of circuits by ganging. They are used for Serialing or Paralleling to
derive different circuit capacity . The power of Battery supply can be increased by serialing .The power of resistor can be increased by
Paralleling.

Applications: In Railway coaches for controling the Battery supply, In Dept of Telecommunication panels and special application circuits.

PROG
NO.

DESCRIPTION

61109

2 Gang with OFF


1 Pole

SCRIPT PLATE MARKING

CONNECTING DIAGRAM/
TERMINAL MARKING

NO OF
STAGES

Length L = No of Stages x S + W

B 21 * IP 40 Protection from front

TYPE
S6/S10/TP6/TP10
S16/TP16/RT16
S25/S32/RT25/RT32

1
2 GANG

61117

2 Gang with OFF


2 Pole

B1

B2

B3

MAX

20
36
48

9
12
12

4.5
4.5
5.5

33
46
52

32
48
64

9.5
12
15

28.5
37
38

10
12
8

Features : - * Mounted on Rear side of the panel and operated from the front door * Door interlockable mechanism & panel door openable
only in OFF position. * Provides a safety feature.* Knob / Handle operatable

600

61111

2 Gang with OFF


3 Pole

61110

3 Gang with OFF


1 Pole

3 GANG

2
Length L = No of Stages x S + W

61118

B42/B41 * IP 55 Protection from front

3 Gang with OFF


2 Pole

TYPE

900

61112

S16/TP16/RT16
S25/S32/RT25/RT32
S40/S63/RT40/RT63
S80/S100/S125
S200
S400

3 Gang with OFF


3 Pole
5

61113

2 Gang, Series
With OFF 1 Pole

A1

A2

B1

B2

B3

MAX

48
48
81
81
81
81

M5
M5
M6
M6
M6
M6

48
48
68
68
68
68

15
15
18
18
18
18

4.5
4.5
5.5
5.5
5.5
5.5

60
60
101
101
101
101

64
64
88
88
88
88

3.5
3.5
5
5
5
5

45
41
46
46
46
46

22
22
26
26
26
34

12
15
21
26
32
64

54
55
66
72
72
72

8
8
6
6
6
3

Features : - * Mounted on rear side of the panel and operated from the front door * Door interlockable mechanism & door openable only in
OFF position. with round padlockable device.* Secure with max 3 Padlocks in OFF position
2 GANG SERIES
1

61115

2 Gang, Series
With OFF 2 Pole
900

61114

2 Gang, Series
With OFF 3 Pole
3
B 34

2 GANG SERIES PARALLEL

61116

2 Gang
Series-Parallel
With OFF 2 Pole

2
900
Feasible Ampere Rating : 6,10,16,25,32,40 & 63

14

Length L = No of Stages x S + W

* IP 55 Protection front
TYPE

A1

A2

B1

B2

B3

MAX

S16/TP16/RT16
S25/S32/RT25/RT332
S40/S63/RT40/RT63
S80/S100/S125
S200
S400

48
48
68
81
81
81

M5
M5
M6
M6
M6
M6

36
36
68
68
68
68

15
15
18
18
18
18

4.5
4.5
5.5
5.5
5.5
5.5

60
60
84
101
101
101

65
65
95
95
95
95

3.5
3.5
5
5
5
5

45
41
46
46
46
46

24.5
24.5
33.5
33.5
33.5
33.5

12
15
21
26
32
64

54
55
66
72
72
72

6
6
6
6
6
3

19

CAM OPERATED ROTARY SWITCHES

CAM OPERATED ROTARY SWITCHES


MOTOR CONTROL SWITCHES

KNOBS / HANDLE

MOTOR CONTROL SWITCHES:


These switches directly operate the motor with AC3 or AC4 Duty Rating. They are mainly used for motor Forward - Reversing , Star -Delta,
Two speed Forward -Reversing and other special switches designed to operate with a Contactor with buit-in tripping feature in the event
of Power failure and Overload.

ACCESSORIES
EXTENDED TERMINALS
S16

S25

S63

MOTOR REVERSING SWITCHES


PROG
NO.

DESCRIPTION

61210

2 POLE

61211

3 POLE

61253

3 POLE SPRING
RETURN

SCRIPT PLATE MARKING

CONNECTING DIAGRAM/
TERMINAL MARKING

Spring
Return
to 0

NO OF
STAGES

MOTOR SWITCHES / STAR DELTA SWITCHES


PROG
NO.

61200

DESCRIPTION

SCRIPT PLATE MARKING

CONNECTING DIAGRAM/
TERMINAL MARKING

OFF-STAR-DELTA

Always mounted on switch supplied as optional for S40 and S63

NO OF
STAGES

4
ALWAYS MOUNTED ON SWITCH
S80, S100, S125,

61201

Spring Return
From STAR to OFF

61203

Standard

61239

Star Delta
with Sequence
Locking & LMD
Contacts

61240

For use with


Contactors

Always mounted on switch

S400

PUSH ON TERMINALS
S16

Mating terminal socket Code No : 1653

Feasible Ampere Rating : 6,10,16,25,32,40 & 63 Amps

12

21

CAM OPERATED ROTARY SWITCHES

CAM OPERATED ROTARY SWITCHES


INSTRUMENTATION SWITCHES

CUSTOMISED PROGRAMME FORMATION

INSTRUMENTATION SELECTOR SWITCHES:


With the help of these switches we can * Measure Currents in different circuits
with Current Transformer, a single Ammeter & a switch * Measure Voltages between
phases and phase & Neutral with one voltmeter & a switch * Measure Voltages &
Currents of a circuit with one Voltmeter, one Ammeter and a single switch.

VOLTMETER SELECTOR SWITCHES


PROG
NO.

DESCRIPTION

61312

3 ph Line to Line

61313

3 ph Line to Line &


Line to Neutral

61314

3 ph Line to Line
Line to Neutral &
without Off

61317

3 ph Line to Line &


L1 to N

61318

3 ph Line to Line
2 Sources

61311

3 ph Line to Neutral

61319

3 ph Line to Line
Without Off

SCRIPT PLATE MARKING

CONNECTING DIAGRAM/
TERMINAL MARKING

NO OF
STAGES

Feasible Ampere Rating : 6,10 & 16 Amps

VOLTMETER & AMMETER SELECTOR SWITCHES


PROG
NO.

DESCRIPTION

61336

3 Voltages
Line - Line &
3 Currents

61337

4 Voltages &
3 Currents

61338

3 Voltages
Line to Neutral
& 3 Currents

SCRIPT PLATE MARKING

CONNECTING DIAGRAM /
TERMINAL MARKING

NO OF
STAGES

Feasible Ampere Ratings : 6,10 & 16 Amps

10

23

CAM OPERATED ROTARY SWITCHES

CAM OPERATED ROTARY SWITCHES


MULTISTEP SWITCHES WITH OFF

ORDERING INFORMATION

MULTISTEP (POLE-WAY) SWITCHES WITH OFF


These switches are also called as Pole-Way switches, they are
available with OFF & without OFF. Multistep does the function of
connecting different circuits to a common supply or vice-versa.
1 pole, 2 pole & 3 pole is popular for 1 Ph, 2 Ph & 3 Ph supply.

Programme Code

Application:- Typical usage Tap changing switch for Transformer /


Stablizer and other special application circuits.

PROG
NO.

DESCRIPTION

61059

1 Pole-2 Way

61079

2 Pole-2 Way

61099

3 Pole-2 Way

Example:-

CONNECTING DIAGRAM /
TERMINAL MARKING

SCRIPT PLATE MARKING

1
oA1

2 WAY - 600

61130

4 Pole-2 Way

61060

1 Pole-3 Way

61080

2 Pole-3 Way

61100

3 Pole-3 Way

61131

4 Pole-3 Way

61061

1 Pole-4 Way

61081

2 Pole-4 Way

61101

3 Pole-4 Way

61132

4 Pole-4 Way

61062

1 Pole-5 Way

61082

2 Pole-5 Way

61102

3 Pole-5 Way

61063

1 Pole-6 Way

61083

2 Pole-6 Way

61103

3 Pole-6 Way

61064

1 Pole-7 Way

61084

2 Pole-7 Way

NO OF
STAGES

oB1

oA2

oC1

oB2

oD1

oC2

oD2

3
1 to 4 pole

4
2

A3o 1

3 WAY - 900

o A1 B3 o 2

o
A2

o B1 C3o 3

o
B2

o C1 D3 o 4
o
C2

o D1
o
D2

o A1

o B1

4 WAY - 600

o C1

A4 o

o A2

B4 o

A3 o

o B2

C4 o

B3 o

o D1

4
o C2 D4 o

C3 o

o D2

D3 o

A5 o

o A1
1

5 WAY - 60

A4 o

o A2

B5 o
2
B4 o

o A1

6 WAY - 450

1
A5 o
o
A4

o A2
o A3

o C1

3
C4 o

o C2

o
C3

o
B4
1 to 3 pole

Programme Selector Table


Programmes
Isolators
Changeovers with OFF
Changeovers without OFF
Multistep with OFF
Multistep without OFF
Instrumentation Switches
Motor Control
Gang Switches
Control Switches

Type Selection
Type
S-Series
Touch Proof
Rear Acess Termination
DC Switches
Phase Selector only for
1 pole 3 way with OFF

Prog Code
Pg 3
Pg 4
Pg 5
Pg6
Pg 7
Pg 8 & 9
Pg 10 & 11
Pg 12
Pg 13

C6 o 3
o B3

o
C4

o C2
oC3
C5 o

Color

Ampere Selection

Code Possible Amps


S
6 to 400 Amps
T
6 to 16 Amps
R
16 to 63 Amps
D
16 to 500 Amps
25 to 63 Amps

Mounting Selection
For Mounting Styles
Refer Table on Page 13

8
o C1

o B2

C5o

o B1
B6 o 2
B5 o

Knob

o B2

1 to 3 pole

A6 o

Mounting

o B1
o
B3

o
A3

Ampere

1 to 4 pole

1 to 4 pole

Type

Ampere
6
10
16
20
25
32
40
50
63
80
100
125
160
200
250
300
400
500
600
800

Code
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T

3
6
9

Knob / Handle Selection


CODE - TD

CODE - FH

CODE - PG

CODE - BG

CODE - LV

TEAR DROP

FLAG KNOB

PISTOL GRIP

BALL GRIP

LEVER HANDLE

4
7 WAY - 450
7
1 to 2 pole

61065

61066

1 Pole-8 Way

1 Pole-9 Way

8 WAY - 300

9 WAY - 300

Color Combination Selection Table


CODE - YR

61067

1 Pole-10 Way

10 WAY - 300

61068

1 Pole-11 Way

11 WAY - 300

Feasible ampere ratings : 6, 10, 16, 25, 32, 40, 63, 80, 100, 125 & 200 Amps

Yellow front plate


Red knob

CODE - GB

Grey front plate


Black knob

CODE - BB

CODE - AB

Black front plate


Black knob

Aluminum Foil with


Black knob

25

CAM OPERATED ROTARY SWITCHES

CAM OPERATED ROTARY SWITCHES


CHANGEOVER PROGRAMMES WITH OFF

BREAKER CONTROL SWITCHES


MOUNTING STYLES
CONNECTING DIAGRAM

B03

Without Jumper
A1 A2

B1 B2 C1 C2 D1 D2

E1 E2 F1 F2 G1 G2 H1 H2

1 3

10

5 7

12

seq.locking
&LMD

9 11

13

1 to 3 Pole

1 to 8 pole

17.50
LxW
LMD
Contacts

MxW
Main
Contacts

Panel gap

3 to 5
65

SQ64

50

12

5.5

NEUTRAL

STAYPUT
D

90 Degree

SALZER

80

60 Degree

C
L
O
S
E

T
R
I
P

SQ48

spring return
stayput 15

Description
1
2
3
4
5
6
7
8

pole
pole
pole
pole
pole
pole
pole
pole

No of
Description
Stage
1
1 pole
2
2 pole
3
3 pole
4
4 pole
5
6
7
8
Rating: 6,10,16,25,32,40,63,80,100,125,200 & 400 Amps

Programme code
61025
61026
61027
61028
61029
61030
61031
61032
Feasible Ampere

DRILLING PLAN

Programme code
61151
61152
61153
61154
-

TYPE
SG25
SG32

D
58
62

No Of Stages in Main Contacts

No Of Stages in LMD Contacts

W
14
16

SPRING RETURN
Spring Return from 1 to 0

45 Degree Spring Return to 0

B90

1 pole
2 pole
3 pole

No of
Description
Stage
61361
1
1 pole
61362
2
2 pole
61363
3
3 pole
Feasible Ampere Rating: 6,10,16,25,32,40 & 63 Amps

Programme code

Seq.locking & LMD

Programme code

13

61364
61365
61369

17.50
LxW
LMD
Contacts

MxW
Main
Contacts

Panel gap

3 to 5
55

SQ64

40

T
R
I
P

75

WITHOUT JUMPER
45 Degree Spring return without Jumper

60 Degree Stayput without Jumper

12

5.5

NEUTRAL

Description

C
L
O
S
E
SALZER

SQ48

spring return
stayput 15

R
DRILLING PLAN

Description
1 pole
without jumper
2 pole
without jumper
3 pole
without jumper

Programme code

No of
Stage

Description

Programme code

62625

1 pole
without jumper

61761

61626

2 pole
without jumper

61762

61627

Feasible Ampere Rating:

Feasible Ampere Rating:

6,10,16,25,32,40,63,80,100,125,200 & 400 Amps

6,10,16,25,32,40 & 63 Amps

TYPE
SG25
SG32

D
58
62

No Of Stages in Main Contacts

No Of Stages in LMD Contacts

W
14
16

27

4
16
16

10
6

6
4
0.7
1.5
0.7
1.5
M3
0.5

A
A
mm2
mm2
mm2
mm2
Metric
Nm
1.5
4
1
2.5
M3.5
0.8

16
5

10
3

6
3

A
KA

0.7
1.5
0.7
1.5
M3
0.5

3
7.5
7.5
0.55
2.2
5.5
5.5

1.8
3
0.37
1.5
3
-

1
2.2
0.25
0.8
1.5
-

KW
KW
KW
KW
KW
KW
KW

A
V
V
kV
A

S16
TP16
16
690
415
6
20

S10
TP10
10
440
250
4
12

S6
TP6
6
440
250
4
8

UNIT

RT20
20
690
415
6
25
3
7.5
7.5
0.55
2.2
5.5
5.5
20
5
20
20
1.5
4
1
2.5
M3.5
0.8

RT16
16
690
415
6
20
3
7.5
7.5
0.55
2.2
5.5
5.5
16
5
16
16
1.5
4
1
2.5
M3.5
0.8

Note :-

120V
240V
120V
240V
480V
600V

S10
10
300
0.33
0.75
1
1
-

S6
6
300
0.25
0.5
0.75
1
-

Unit
A
V
HP
HP
HP
HP
HP
HP

AC4 Rating = AC3 rating / 2


Star Delta Switch Rating = 1.6 X AC3 rating

3 Phase

Ampere Rating
Operational Voltage
HP Rating
1 Phase

AC Rating Code

CSA / UL RATINGS

15
300
0.33
1
1
2
-

S16
TP16
RT16
20
440
0.33
1
1
2
-

RT20
20
600
1
3
2
5
10
15

S25
TP25
RT25
30
600
1
3
2
5
10
15

S32
TP32
RT32

70
600
10
20
40
50

40
600
2
5
5
10
20
24

55
600
3
7.5
7.5
15
30
40

S80

S40
S63
RT40 RT63

Switch Life (Under standard Operating conditions) Mechanical Life : 1 lac Operations @ 300 cycles / hour
Electrical Life : 10,000 Operations at 100 % Rated duty at 120 cycles / hour

Rated Operational Current ( Ie ) AC21A / AC1


Rated Operational Voltage (Ue )
Isolating Voltage upto ( Uiso )
Impulse withstand Voltage ( Uimp )
Rated Uninterrupted Current ( Ith )
Rated Operational Power
AC23A
3 Phase
220-240 V
380-440 V
500-690 V
AC3
3 Phase
110 V
220-240 V
380-440 V
500-690 V
Short Circuit Capacity
Fuse Size (Type gG/gM)
Rated Fuse Short Circuit Current
DC Rating
DC1
(Power)
48V
DC13
(Control)
24V
Terminal Cross Section
Single / Multiple
min
max
Fine strand with sleeve
min
max
Terminal screw
Terminal Tighting Torque

AC RATING CODE

S200
175
600
20
25
50
50

S125
125
600
15
25
50
50

S100
95
600
15
25
50
50

US

US

Indian

: IS 13947-1/3/5, 1993

North
CSA 22.2 No.14-1991
American : UL 508 (1994)

European : IEC-60947-1 : 1988


IEC-60947-3 : 1990
IEC-60947-5 : 1992

10
50
10
35
2xM5
2.5

10
35
10
25
2xM5
2.5
6
25
6
16
2xM5
2.5

4
16
2.5
10
M5
2
2.5
10
2.5
6
M5
2

2.5
6
1.5
4
M4
1.2

1.5
4
1
2.5
M4
1.2

160
160
125
125
100
100
80
80

63
63

40
40

32
32

25
25

10
70
10
50
M10
2.5

200
25
125
25
100
25
80
25

63
20

40
20

32
10

25
10

37
55
45
22
45
45
31
45
41
8.3
17.2
37
37
30
41
37
22
33
33

22
33
30
18.5
22
22

15
22
22
3
15
18.5
18.5

11
18.5
18.5
2.5
7.5
15
15

7.5
15
15
2.2
5.5
11
11

200
690
690
6
225

125
690
690
6
150

100
690
690
6
125

80
690
690
6
100

5.5
11
11
1.5
4
7.5
7.5

S200

S125

S100

S80

S63
RT63
63
690
500
6
80

S40
RT40
40
690
500
6
50

S32
RT32
32
690
415
6
40

S25
RT25
25
690
415
6
32

20
140
20
100
M10
4

250
250

400
50

320
690
690
6
425

S400

CAM OPERATED ROTARY SWITCHES


CAM OPERATED ROTARY SWITCHES

TECHNICAL SPECIFICATION
INSTALLATION PROCEDURE

* Ensure Mating Orientation


with Knob

CAM OPERATED ROTARY SWITCH

* Ensure Mating Orientation


with Knob

BREAKER CONTROL SWITCH

29

CAM OPERATED ROTARY SWITCHES

CAM OPERATED ROTARY SWITCHES

DC SWITCHES
Features

INTRODUCTION
CAM OPERATED ROTARY SWITCHES are defined as set of contacts arranged to
make and break in a sequential fashion by which the connected outputs will either
close or open the circuits.

Applications

Housing made up of SMC material for


rigidity and higher mechanical strength.

D40R Railway coaches lighting & fan


circuits switching.

Wiping contacts operations helps in


dust free & self cleaning concepts.

All DC power circuits Railways,


Telecommunications & Power plants.

Extented terminals for Bus bar/


Aluminium cable connections.

Capston Handle operation for better


leverage

CPRI Tested.

170PCD

D100 - D500

236.00

The main areas of operation are in making, breaking and isolation of power circuits and
switching of auxiliary circuits.
The Cam which does the function of closing & opening of the contacts have multiple
positions ( Rotary Movement) which allows multiple circuit functions controlled through
a single operation.

24

Another advantage, which can be derived, is the flexibility in the Contact block selection,
which gives the user the option to select the number of contacts as per his requirement.
The choice also covers the rating of the applicable Operational Duty. This will ensure
that the right switch is chosen for the application. CAM operated rotary switches also
offers design flexibility to assemble complex switching programmes to customize any
switching application.
The basic operating mechanism of these switches depends on the type of application.
Quick-Make, Quick-Make-Quick-Break and Spring return operating mechanisms can be
chosen.
Usage of high quality engineering materials for various components ensure that the
switches have long life with higher degree of Electrical and Mechanical endurance.
Double Butt contacts with silver bimetal on copper ensure better making and breaking
over conventional knife-edge switches. Usage of high-grade engineering plastics like
Nylon and Celcon for the components and glass filled polyamide construction provides
greater mechanical strength to the switches.
These Cam operated rotary switches have versatile mounting options to suit any kind
of application. Special mounting options like single hole, door interlocking and padlocking
are also available.

0.8

1.5

These switches are suitable for AC as well as DC applications. By virtue of CAM


design functions like Make Before Break type of contacts can be easily achieved. The
number of positions and the switching angle are flexible and will offer the user a
choice to decide based on the requirement.

3.1

1.5

138.5

DESCRIPTION
DUTY RATING - DC 22A L/R 2M sec
Operational Voltage
Voltage for AC Rating
Operational Current
Thermal Current ? I th ?
Switching Angle
Maximum Contact Stages

D100-D500 WITH DIL

UNIT

D100

D200

D300

D400

D500

VDC
VAC
A
A
Deg

250
460
100
125
90
9

250
460
200
250
90
9

250
460
300
375
90
9

250
460
400
500
90
9

250
460
500
625
90
9

170PCD
1

The enclosed sheets will give an indepth view into the various types of switches,
Mountings, Switching Programmes, Optional Accessories and the Ordering procedure
for CAM OPERATED ROTARY SWITCH.

236.00

Greater importance is attached to the aesthetics of the switches. These switches


come with attractive combination of knobs and front plates to render greater compatibility
to the panel design. User defined marking on the script plate with different sizes of
script plates eliminate the need to label the switch on the panel.
24

1.5
L

0.8

1.5

3.1
138.5