Академический Документы
Профессиональный Документы
Культура Документы
NOTES
CONTENTS
Page no
32
Introduction
General Construction
Technical Specification
Isolators/on-off Switches
Instrumentation Switches
10
12
Gang Switches
14
Control Switches
15
16
Knobs / Handle
20
22
23
Ordering Information
25
26
Installation Procedure
29
DC Switches
30
DC SWITCHES
Features
Applications;
DC power circuits
D16 D63
3 to 5
Panel gap
Drilling plan
B3
B2
D
SQ F
CAM ASSEMBLY
TYPE
D16
D25/32
D40/63
Stages
D16
D25/32
D40/63
Length in
mm
Salzer switches S, TP & RT series are designed to accomodate two isolated Double break silver alloy contacts per stage at 180 degree
disposition. AC Switches are characterised by Quick make-slow break action by the inbuilt feature in our latching device and cam
construction, these switches can be applied for DC Switching also by Derating and by adding additional contacts in series according to the
DC Switching voltage.
SQ B1
B1
48
48
68
B2
12
12
15
B3
5.5
5.5
5.5
D
50
50
70
CONTACT ASSEMBLY
F
64
64
64
S
12
15
21
10
11
12
62
65
69
74
80
90
86
95
111
98
110
132
110
125
153
122
140
174
134
155
195
146
170
216
158
185
237
170
200
258
182
215
279
194
230
300
Contacts
S SERIES
STANDARD
Operating Temp
: -25OC to 55oC
Operating Frequency
: Upto 10KHz
Humidity 95% Rh
: 48 hours
TP SERIES
TOUCH PROOF
RT SERIES
REAR TERMINATION
TECHNICAL SPECIFICATION
DC
RATINGS
DESCRIPTION
GENERAL
250V
460V
D16
D25
D32
D40
D63
20
32
40
50
80
16
25
32
40
63
48V
70V
110V
180V
250V
A
10
16
25
32
40
6
7
10
14
20
25
16
25
32
40
63
Fuse Protection
16
25
32
40
63
kA
10
10
20
20
mm2
1.5
1.5
1.5
1.5
1.5
mm2
10
16
Nm
0.8
1.2
1.2
16
10
10
Terminal
Cross Section
Maximum Contact Stages
380-440V
[Rigid] min
[Flex]
max
AC Duty Rating
Category
Hp
Tightening Torque
30
UNIT
DC Duty Rating
Typical AC Application
Category
Typical DC Application
AC-1
DC-1
AC-3
DC-22
DC-13
Control of DC electromagnets
AC-21A
AC-15
DC-23
AC-23-A
----
-----
ISOLATORS-ON/OFF SWITCHES
ISOLATORS:
Isolators which are ON/ OFF switches are used for making/breaking
electrical circuits for isolation purpose. In rotary switches isolators
are offered in very compact versions from 1 pole to 12 pole for
multiple circuit isolation. The duty category utilisation of the isolators
are categorized as AC1/AC21 for higher duty like motor duty operation
the rating AC3/AC23 should be considered
Isolators can be offered with stayput /spring return and preclose
contacts for neutral & earth closing applications.
Example:-
10
CONNECTING DIAGRAM
25 Ampere Spring return TNC with 1 set of Main Contact 1NO+1NC,
1 LMD contact in Trip position & 1 LMD contact in Close position with
Sequential locking and Barrell Lock Mounting
11 13 15
17 19 21
10 12 14 16 18
20 22
23
24
1 to 12 pole
Digit 1
Digit 5
Digit 2
Sequence Locking
If required
Not required
Code
Q
O
Digit 3
Latching Mechanism
Spring Return
Stayput
Code
S
C
STAYPUT
Digit 6
No of LMD Contacts
Position
Description
1 Contact
2 Contact
3 Contact
4 Contact
5 Contact
6 Contact
If not required
in Close
Code
1
2
3
4
5
6
0
60 Degree
90 Degree
Description
Programme Code
Programme Code
Programme Code
No of Stage
1 Pole
2 Pole
3 Pole
4 Pole
5 Pole
6 Pole
7 Pole
8 Pole
9 Pole
10 Pole
11 Pole
12 Pole
61001
61002
61003
61004
61005
61006
61007
61008
61009
61010
61011
61012
61191
61192
61199
61194
61906
-
61195
61198
61197
61196
-
1
1
2
2
3
3
4
4
5
5
6
6
Script Plate
Marking
Digit 7
90 Degree
Ampere Rating
25 Ampere
32 Ampere
Digit 4
LMD Contacts
If required
Not required
Code
L
D
10
4 to 5 pole
Description
28
Code
E
F
Digit 8, 9, 10
Mounting
Standard Front Mounting
Barrei Lock with Centre
Key
Code
B03
B90
Programme code
61194
No of
Stage
2
2
3
2
1 to 4 pole
Description
Programme code
No of
Stage
1
1
2
2
OPERATIONS
CONNECTING DIAGRAM
A1
B1
C1
D1
E1 F1
F1
H1
J1
K1
L1
M1
A2 B2
C2
D2
E2 F2
F2
H2
J2
K2
L2
M2
2 4
Without Jumper
6 8
10 12 14 16
1 3
5 7
1 to 12 pole
9 11
13 15
1 to 4 Pole
LMD operations
DESCRIPTION
UNIT
Ue
Uimp
Ith
Ie
20-240V AC
380-440V AC
min
max
min
max
Flexible wire
Terminal Screw
Terminal Tightening Torque
CSA / UL RATINGS
Voltage Rating
Ampere Rating
V ac
V dc
kV
A
SG25
690
250
6
32
SG32
690
250
6
40
A
A
8
5
14
6
25
32
kA
10
10
1.5
4
1
2.5
M4
1.2Nm
2.5
6
1.5
4
M4
1.2Nm
mm2
mm2
V
A
VA Rating
50 V
125 V
250 V
26
1
2
3
1
2
3
1
2
3
Resistive
Amps
20
3
20
1.0
5
20
1
2
3
4
60 Degree
No of
Stage
5
6
7
8
9
10
11
12
No of
Description
Programme code
Stage
61037
1
5 pole
61041
61038
2
6 pole
61042
61039
3
61043
7 pole
61040
4
8 pole
61044
--9 pole
61045
--61046
10 pole
--11 pole
61047
--12 pole
61048
Feasible Ampere Rating Applicable : 6,10,16,25,32,40,63,80,100,125,200 & 400 Amps
Description
SIL Operations
Programme code
pole
pole
pole
pole
-----
SPRING RETURN
45 Degree Spring Return
TECHNICAL SPECIFICATION
GENERAL :-
Description
ENDURANCE
600
20
600
30
AC-720 VA
DC-275 VA
Programme code
1 pole
61371
2 pole
61372
3 pole
61373
Feasible Ampere Rating: 6,10,16,25,32,40 & 63 Amps
No of
Stage
1
2
3
WITHOUT JUMPER
45 Degree Spring return without Jumper
Frequency up to 5 KHz
SG 25
No of
Voltage Contacts in
series
STAYPUT
SG 32
Inductive L / R Amps
10
m sec
20
m sec
40
m sec
20
2.5
15
20
0.5
2
10
15
20
1.5
10
20
0.3
1.0
4
6
14
20
1.0
5
10
0.2
0.5
1
Resistive
Amps
25
5
25
1.2
6
25
Inductive L / R Amps
10
m sec
20
m sec
40
m sec
25
3
18
25
0.6
2.5
12
18
25
2
12
25
0.4
1.2
5
8
18
25
1.2
6
12
0.3
0.6
1.2
Description
1
2
3
4
pole
pole
pole
pole
without
without
without
without
Programme code
jumper
jumper
jumper
jumper
Feasible Ampere Rating
6,10,16,25,32,40,63,80,100,125,200
61637
61638
61639
61640
:
& 400 Amps
No of
Stage
1
2
3
4
Description
Programme code
61771
-
Switch Positions
PROG
NO.
DESCRIPTION
61049
1 Pole-3 Way
61069
2 Pole-3 Way
61089
3 Pole-3 Way
61120
4 Pole-3 Way
61124
5 Pole-3 Way
61126
6 Pole-3 Way
61050
1 Pole-4 Way
61070
2 Pole-4 Way
61090
3 Pole-4 Way
61121
4 Pole-4 Way
61051
1 Pole-5 Way
61071
2 Pole-5 Way
61091
3 Pole-5 Way
61122
4 Pole-5 Way
61052
1 Pole-6 Way
61072
2 Pole-6 Way
61092
3 Pole-6 Way
61053
1 Pole-7 Way
61073
2 Pole-7 Way
61093
3 Pole-7 Way
61054
1 Pole-8 Way
61074
2 Pole-8 Way
61094
3 Pole-8 Way
61055
1 Pole-9 Way
61056
CONNECTING DIAGRAM /
TERMINAL MARKING
NO OF
STAGES
5
3 WAY - 600
6
8
1 to 6 pole
9
2
4
4 WAY - 900
6
1 to 4 pole
8
3
5
5 WAY - 600
8
1 to 4 pole
10
3
6 WAY - 60
1 to 3 pole
9
4
7
7 WAY - 450
1 to 3 pole
11
4
8
8 WAY - 450
1 to 3 pole
12
9 WAY - 300
1 Pole-10 Way
10 WAY - 300
61057
1 Pole-11 Way
11 WAY - 300
61058
1 Pole-12 Way
12 WAY - 300
NIGHT LAMP
61649
1 Pole-3 Way
Without Off
Without Jumper
61650
1 Pole-4 Way
Without Off
Without Jumper
61670
2 Pole-4 Way
Without Off
Without Jumper
4 WAY - 900
2
4 WAY - 900
4
1 to 2 pole
24
INSTRUMENTATION SWITCHES
BIGGER
STYLE
FRAME SIZE
S6/S10
TP6/TP10
ACCESSORIES
--
SHROUDING COVERS
PROG
NO.
DESCRIPTION
CONNECTING DIAGRAM /
TERMINAL MARKING
61325
1 Pole-3
Transformer
With OFF
61321
1 Pole-1
Transformer
NO OF
STAGES
Rectangular
S16
TP16
RT16
S6/S10
TP6/TP10
61331
1 Pole-2
Transformer
TYPE
S25/S32
RT25/RT32
S63
S200
--
61384
1 Pole-3
Transformer
Without OFF
61326
1 Pole-4
Transformer
With OFF
61327
2 Pole-2
Transformer
W3ith OFF
61328
3 Pole-3
Transformer
With OFF
61329
3 Pole-3
Transformer
Without OFF
61330
4 Pole-4
Transformer
Without OFF
71000
Direct Ammeter
Selector
Without Current
Transformer
S16
TP16
RT16
S25/S32
RT25/RT32
175
210
175
210
115
200
110
200
100
90
115
100
NO. OF
STAGES
3
3
3
3
S16
TP16
RT16
--
64 x 80
D
S25/S32
RT25/RT32
S16
TP16
RT16
TYPE
S25/S32
S63
65+0.2
89+0.2
H
2 STAGE
48
118
3 STAGE
63
182
73078
2
One Voltage
Transformer
Two Current
Transformer
CODE - YR
CODE - GB
CODE - BB
CODE - AB
WATTMETER SWITCH
73071
Yellow Front Plate
Red Knob
22
Two Wattmeter
Method
3 WAY- 900
:
11
PROG
NO.
DESCRIPTION
61212
2 Speed
Single Winding
61213
2 Speed
Single Winding
61215
2 Speed
Single Winding
For use with
Contactors
61217
2 Speed
Single Winding
Reversing
61219
2 Speed
2 Seperate
Windings
61226
3 Speed
2 Windings
(O-A-B-A)
61243
3 Speed
2 Windings
(O-A-B-B)
RED
CONNECTING DIAGRAM/
TERMINAL MARKING
NO OF
STAGES
BLACK
TD - TEAR DROP
CODE - TD
S6/S10/TP6/TP10
S16/TP16/RT16
S25/S32/RT25/RT32
S40 & ABOVE
FL - FLAG KNOB
27
27
36
50
41
41
52
70
25
25
31
42
21
21
25
33
CODE - FL
S6/S10/TP6/TP10
S16/TP16/RT16
S25/S32/RT25/RT32
S40 & ABOVE
16.5
27
36
50
22
39
50
68
13.75
24
27
42.5
18
24
25
32
LV - LEVER HANDLE
MOTOR SWITCHES - START & RUN SWITCHES
PROG
NO.
DESCRIPTION
CONNECTING DIAGRAM/
TERMINAL MARKING
NO OF
STAGES
90
Split-phase Start
CODE - PG
Applicable for
S16 / TP16 / RT16
S25 / S32 / RT25 / RT32
S40 / S63
20
CODE - BG
Applicable for
S16 / TP16 / RT16
S25 / S32 / RT25 / RT32
S40 / S63
CODE - LV
Applicable for
S80 / S100 / S125
S200 / S400
61209
Split-phase Start
Reversing
61270
Split-phase Start
Reversing
Switching
13
CONTROL SWITCHES
Features : - * Switches Mounted in ABS Plastic Enclosure * Provides protection from dust & hazardous material * with Round Padlockable
Device * Secure with max 3 Padlocks in OFF position * Prevents operational access to Unauthorised Personnel * Suitable for 900 switches.
CONTROL SWITCHES:
Control switches are used to energise contactors for controlling motor operations. Most of the switches are of Spring return type to enable
latching of the circuit with Contactors NO contact to facilitate tripping by Contactors Tripping device.
Applications: Control switches are a unique alternative for many of the Push Button stations, where it is preferred to control a system with
one switch instead of many Push Buttons. Many positions of the switch are possible to derive combinations.
PROG
NO.
DESCRIPTION
61300
1 Pole STOP-START
With Spring Return
61388
2 Pole STOP-START
With Spring Return
CONNECTING DIAGRAM/
TERMINAL MARKING
NO OF
STAGES
1
spring return
B 31
TYPE
S16/TP16/RT16
S25/S32/RT25/RT32
S40/S63/RT40/RT63
42
42
48
110
125
175
80
100
125
66
70
90
60 90
80 115
105 155
STAGES
3
2
2
Features : - * Switches Mounted in sheet metal enclosures *Provides protection from dust & hazardous enviorement. *Knob / Handle
operatable * Suitable for switches upto 32 Ampere
61301
61701
61307
1 Pole STOP-START
With Spring Return
From START to RUN
Without Jumper
STOP-START SWITCH
With Spring Return
to run for 2 units
61707
Without Jumper
61366
Contactor Control
With Spring Return
to OFF
spring
return from
start to 1
spring return
from start
spring
return to 0
61271
M 17
TYPE
S6/S10/TP6/TP10
S16/TP16/RT16
S25/S32/RT25/RT32
16 Ampere For/ Reverse
A1
A2
A3
D1
D2
D3
70
70
70
81
60
60
60
65
4
4
4
5
85
85
85
75
89
89
89
75
98
98
98
110
MAX
4
4
3
-
Features : - * Four hole base mounted on Rear side of the Panel * Knob/ Handle operatable
Length L = No of Stages x S + W
S6/S10/TP6/TP10
S16/TP16/RT16
S25/S32/RT25/RT32
S40/S63/RT40/RT63
S80/S100/S125
S200
S400
18
A1
A2
B1
B2
B3
MAX
36
48
48
68
81
81
81
M5
M5
M5
M6
M6
M6
M6
36
36
48
68
68
68
68
9
12
12
15
15
15
15
4.5
4.5
4.5
5.5
5.5
5.5
5.5
48
60
60
84
101
101
101
32
48
64
88
88
88
88
4.5
3.5
3.5
5
5
5
8
9.5
12
15
21
26
32
64
22
30
31
41
48
48
48
10
12
8
6
6
6
3
Motor Voltage
Control Switch
Description
Front Mounting S25/S32 Switches with 48x48 plate
Rear/Back Mounting with Standard Front Plate
Front Mounting, Standard Mounting Plate
Rear/Back Mounting with next size plate
Front Mounting with next size plate
Single Hole Mounting 48x48 plate for S6 to S32
Single Hole Mounting 32x32 plate for S6 & S10
Din Rail Mounting on 35 mm Rail
Front Mounting with Rectangular padlock
Rear/Back Mounting, Door Interlock + Rectangular Padlock (B42+B30)
Front Mounting with Round padlock
Rear Mounting, Door Interlock + Round Padlock (B33+B42)
Rear Mounting with Door Clutch Mechanism (Door Opens in both pos)
Rear Mounting with Door Interlock
Single Hole Mounting, Key operated without Front Plate
Single Hole Mounting, Key operated with Front Plate
Front Mounting, Knob/handle Operatable, Lockable with Key
Front Mounting with Centre Key Lock
Door Clutch + Rectangular Padlock Mounting Plate at Front
Door Clutch without Padlock, Mounting Plate at Front
Door Clutch, Front Plate of Next size, Mounting Plate at Front
SS Enclosure
Max stages
Aluminium Enclosure
Max stages
PVC/ABS Enclosure
Max stages
PVC/ABS Enclosure with Round Padlock
Max stages
S6/10
S16
Feasibility -
S25/32 S40/63 S80/100/125
S200/400
15
LOCKABLE SWITCHES
FRONT MOUNTINGS
Features : * Standard 4 hole Front panel Mounting * Knob / Handle operatable * Suitable for all switching angles & Spring return switches *
Front Assembly in 4 different colors Yellow/Red, Grey/Black, Black/Black, Aluminum Finish.
3 to 5
Panel gap
Drilling plan
B3
Features : - * Four Hole Round padlockable mounting * Secure with max. 3 padlocks in OFF position. prevents operational access to
unauthorised personnel.* Suitable for switches only with 900 Switching angle
Drilling plan
6/10 Amps only
B2
3
QB
QD
SQF
2
B
B1
SQ B1
Length L = No of Stages x S + W
TYPE
TYPE
S6/S10/TP6/TP10
S16/TP16/RT16
S25/S32/RT25/RT32
S40/S63/RT40/RT63
S80/S100/S125
S200
S400
B1
B2
B3
20
36
48
68
68
68
68
9
12
12
15
15
15
15
4.5
4.5
5.5
5.5
5.5
5.5
5.5
24
29
36
46
46
46
46
33
46
52
76
92
88
88
32
48
64
88
88
88
88
9.5 18.5
12
26
15
27
21
33
26
40
32
40
64
40
MAX
12
21
15
10
10
10
4
S16/TP16/RT16
S25/S32/RT25/RT32
S40/S63/RT40/RT63
S80/S100/S125
S200
S400
B1
B2
B3
MAX
36
36
68
68
68
68
12
12
15
15
15
15
4.5
4.5
5.5
5.5
5.5
5.5
46
52
76
92
88
88
65
65
95
95
95
95
26
26
31
31
31
31
12
15
21
26
32
64
26
27
33
40
40
40
12
8
6
6
6
3
Features : - * Four Hole Rectangular Padlockable mounting * Secure with max four padlocks in OFF position.* Prevents Operational Acess
to Unauthorised Personnel * Suitable for switches with 900 Switching angle .
Features : - * Single hole mounting with std dia 22.5 mm * Eleminates the need for screws / Hardware for panel fixing * Easy Termination *
Suitable upto 32 Ampere
Locking lever
3
13
3 Max.
Panel gap
Length L = No of Stages x S + W
23
Length L = No of Stages x S + W
TYPE
S6/S10/TP6/TP10
S16/TP16/RT16
S25/S32/RT25/RT32
CODE
B19
B14
B19
B19
33
33
46
52
32
48
48
48
9.5
9.5
12
15
10
13
13
13
28.5
28.5
36
37
MA-X
12
12
21
15
Features : - * Key Operated safety switch, prevents operational access to unauthorised personnel., * Available with or without Front plate
* Suitable up to 32 Ampere.
Length L = No of Stages x S + W
3 to 5
Panel gap
B1
B2
F1
F2
F3
MAX
S16/TP16/RT16
S25/S32/RT25/RT32
S40/S63/RT40/RT63
S80/S100/S125
S200
S400
48
48
68
68
68
68
12
12
15
15
15
15
46
52
76
92
88
88
75
75
98
98
98
98
102
102
126
126
126
126
13.5
13.5
16
16
16
16
23
23
25
255
25
25
12
15
21
26
32
64
26
27
33
40
40
40
12
8
6
6
6
2
Features : - * Knob / handle operatable Switch * With Key lockable Assembly prevents switching by unauthorised personnel. *Key lock / Key
removable only in OFF position * Lock Assembly can also be provided on top
Drilling plan
B3
B2
TYPE
B1
FRONT PLATE
16
B1
B2
B3
MAX
23
23
13.5
13.5
2.5
2.5
46
52
28
28
12
15
37
38
5
5
TYPE
S16/TP16/RT16
S25/S32/RT25/RT32
S40/S63/RT40/RT63
Length L = No of Stages x S + W
B2
B4
B5
MAX
15
15
15
23
23
23
43.5
43.5
43.5
46
52
76
64
64
64
12
15
21
45
45
47
12
12
6
17
REAR MOUNTINGS
GANG SWITCHES:
Features : * Snap mounting base on Din EN50022 ( Omega) rail 35mm & 1.2 mm thick * or Two Hole rear mounting.* Provides Easy Termination
These switches are called Gang switches, as they increase the capacity of circuits by ganging. They are used for Serialing or Paralleling to
derive different circuit capacity . The power of Battery supply can be increased by serialing .The power of resistor can be increased by
Paralleling.
Applications: In Railway coaches for controling the Battery supply, In Dept of Telecommunication panels and special application circuits.
PROG
NO.
DESCRIPTION
61109
CONNECTING DIAGRAM/
TERMINAL MARKING
NO OF
STAGES
Length L = No of Stages x S + W
TYPE
S6/S10/TP6/TP10
S16/TP16/RT16
S25/S32/RT25/RT32
1
2 GANG
61117
B1
B2
B3
MAX
20
36
48
9
12
12
4.5
4.5
5.5
33
46
52
32
48
64
9.5
12
15
28.5
37
38
10
12
8
Features : - * Mounted on Rear side of the panel and operated from the front door * Door interlockable mechanism & panel door openable
only in OFF position. * Provides a safety feature.* Knob / Handle operatable
600
61111
61110
3 GANG
2
Length L = No of Stages x S + W
61118
TYPE
900
61112
S16/TP16/RT16
S25/S32/RT25/RT32
S40/S63/RT40/RT63
S80/S100/S125
S200
S400
61113
2 Gang, Series
With OFF 1 Pole
A1
A2
B1
B2
B3
MAX
48
48
81
81
81
81
M5
M5
M6
M6
M6
M6
48
48
68
68
68
68
15
15
18
18
18
18
4.5
4.5
5.5
5.5
5.5
5.5
60
60
101
101
101
101
64
64
88
88
88
88
3.5
3.5
5
5
5
5
45
41
46
46
46
46
22
22
26
26
26
34
12
15
21
26
32
64
54
55
66
72
72
72
8
8
6
6
6
3
Features : - * Mounted on rear side of the panel and operated from the front door * Door interlockable mechanism & door openable only in
OFF position. with round padlockable device.* Secure with max 3 Padlocks in OFF position
2 GANG SERIES
1
61115
2 Gang, Series
With OFF 2 Pole
900
61114
2 Gang, Series
With OFF 3 Pole
3
B 34
61116
2 Gang
Series-Parallel
With OFF 2 Pole
2
900
Feasible Ampere Rating : 6,10,16,25,32,40 & 63
14
Length L = No of Stages x S + W
* IP 55 Protection front
TYPE
A1
A2
B1
B2
B3
MAX
S16/TP16/RT16
S25/S32/RT25/RT332
S40/S63/RT40/RT63
S80/S100/S125
S200
S400
48
48
68
81
81
81
M5
M5
M6
M6
M6
M6
36
36
68
68
68
68
15
15
18
18
18
18
4.5
4.5
5.5
5.5
5.5
5.5
60
60
84
101
101
101
65
65
95
95
95
95
3.5
3.5
5
5
5
5
45
41
46
46
46
46
24.5
24.5
33.5
33.5
33.5
33.5
12
15
21
26
32
64
54
55
66
72
72
72
6
6
6
6
6
3
19
KNOBS / HANDLE
ACCESSORIES
EXTENDED TERMINALS
S16
S25
S63
DESCRIPTION
61210
2 POLE
61211
3 POLE
61253
3 POLE SPRING
RETURN
CONNECTING DIAGRAM/
TERMINAL MARKING
Spring
Return
to 0
NO OF
STAGES
61200
DESCRIPTION
CONNECTING DIAGRAM/
TERMINAL MARKING
OFF-STAR-DELTA
NO OF
STAGES
4
ALWAYS MOUNTED ON SWITCH
S80, S100, S125,
61201
Spring Return
From STAR to OFF
61203
Standard
61239
Star Delta
with Sequence
Locking & LMD
Contacts
61240
S400
PUSH ON TERMINALS
S16
12
21
DESCRIPTION
61312
3 ph Line to Line
61313
61314
3 ph Line to Line
Line to Neutral &
without Off
61317
61318
3 ph Line to Line
2 Sources
61311
3 ph Line to Neutral
61319
3 ph Line to Line
Without Off
CONNECTING DIAGRAM/
TERMINAL MARKING
NO OF
STAGES
DESCRIPTION
61336
3 Voltages
Line - Line &
3 Currents
61337
4 Voltages &
3 Currents
61338
3 Voltages
Line to Neutral
& 3 Currents
CONNECTING DIAGRAM /
TERMINAL MARKING
NO OF
STAGES
10
23
ORDERING INFORMATION
Programme Code
PROG
NO.
DESCRIPTION
61059
1 Pole-2 Way
61079
2 Pole-2 Way
61099
3 Pole-2 Way
Example:-
CONNECTING DIAGRAM /
TERMINAL MARKING
1
oA1
2 WAY - 600
61130
4 Pole-2 Way
61060
1 Pole-3 Way
61080
2 Pole-3 Way
61100
3 Pole-3 Way
61131
4 Pole-3 Way
61061
1 Pole-4 Way
61081
2 Pole-4 Way
61101
3 Pole-4 Way
61132
4 Pole-4 Way
61062
1 Pole-5 Way
61082
2 Pole-5 Way
61102
3 Pole-5 Way
61063
1 Pole-6 Way
61083
2 Pole-6 Way
61103
3 Pole-6 Way
61064
1 Pole-7 Way
61084
2 Pole-7 Way
NO OF
STAGES
oB1
oA2
oC1
oB2
oD1
oC2
oD2
3
1 to 4 pole
4
2
A3o 1
3 WAY - 900
o A1 B3 o 2
o
A2
o B1 C3o 3
o
B2
o C1 D3 o 4
o
C2
o D1
o
D2
o A1
o B1
4 WAY - 600
o C1
A4 o
o A2
B4 o
A3 o
o B2
C4 o
B3 o
o D1
4
o C2 D4 o
C3 o
o D2
D3 o
A5 o
o A1
1
5 WAY - 60
A4 o
o A2
B5 o
2
B4 o
o A1
6 WAY - 450
1
A5 o
o
A4
o A2
o A3
o C1
3
C4 o
o C2
o
C3
o
B4
1 to 3 pole
Type Selection
Type
S-Series
Touch Proof
Rear Acess Termination
DC Switches
Phase Selector only for
1 pole 3 way with OFF
Prog Code
Pg 3
Pg 4
Pg 5
Pg6
Pg 7
Pg 8 & 9
Pg 10 & 11
Pg 12
Pg 13
C6 o 3
o B3
o
C4
o C2
oC3
C5 o
Color
Ampere Selection
Mounting Selection
For Mounting Styles
Refer Table on Page 13
8
o C1
o B2
C5o
o B1
B6 o 2
B5 o
Knob
o B2
1 to 3 pole
A6 o
Mounting
o B1
o
B3
o
A3
Ampere
1 to 4 pole
1 to 4 pole
Type
Ampere
6
10
16
20
25
32
40
50
63
80
100
125
160
200
250
300
400
500
600
800
Code
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
3
6
9
CODE - FH
CODE - PG
CODE - BG
CODE - LV
TEAR DROP
FLAG KNOB
PISTOL GRIP
BALL GRIP
LEVER HANDLE
4
7 WAY - 450
7
1 to 2 pole
61065
61066
1 Pole-8 Way
1 Pole-9 Way
8 WAY - 300
9 WAY - 300
61067
1 Pole-10 Way
10 WAY - 300
61068
1 Pole-11 Way
11 WAY - 300
Feasible ampere ratings : 6, 10, 16, 25, 32, 40, 63, 80, 100, 125 & 200 Amps
CODE - GB
CODE - BB
CODE - AB
25
B03
Without Jumper
A1 A2
B1 B2 C1 C2 D1 D2
E1 E2 F1 F2 G1 G2 H1 H2
1 3
10
5 7
12
seq.locking
&LMD
9 11
13
1 to 3 Pole
1 to 8 pole
17.50
LxW
LMD
Contacts
MxW
Main
Contacts
Panel gap
3 to 5
65
SQ64
50
12
5.5
NEUTRAL
STAYPUT
D
90 Degree
SALZER
80
60 Degree
C
L
O
S
E
T
R
I
P
SQ48
spring return
stayput 15
Description
1
2
3
4
5
6
7
8
pole
pole
pole
pole
pole
pole
pole
pole
No of
Description
Stage
1
1 pole
2
2 pole
3
3 pole
4
4 pole
5
6
7
8
Rating: 6,10,16,25,32,40,63,80,100,125,200 & 400 Amps
Programme code
61025
61026
61027
61028
61029
61030
61031
61032
Feasible Ampere
DRILLING PLAN
Programme code
61151
61152
61153
61154
-
TYPE
SG25
SG32
D
58
62
W
14
16
SPRING RETURN
Spring Return from 1 to 0
B90
1 pole
2 pole
3 pole
No of
Description
Stage
61361
1
1 pole
61362
2
2 pole
61363
3
3 pole
Feasible Ampere Rating: 6,10,16,25,32,40 & 63 Amps
Programme code
Programme code
13
61364
61365
61369
17.50
LxW
LMD
Contacts
MxW
Main
Contacts
Panel gap
3 to 5
55
SQ64
40
T
R
I
P
75
WITHOUT JUMPER
45 Degree Spring return without Jumper
12
5.5
NEUTRAL
Description
C
L
O
S
E
SALZER
SQ48
spring return
stayput 15
R
DRILLING PLAN
Description
1 pole
without jumper
2 pole
without jumper
3 pole
without jumper
Programme code
No of
Stage
Description
Programme code
62625
1 pole
without jumper
61761
61626
2 pole
without jumper
61762
61627
TYPE
SG25
SG32
D
58
62
W
14
16
27
4
16
16
10
6
6
4
0.7
1.5
0.7
1.5
M3
0.5
A
A
mm2
mm2
mm2
mm2
Metric
Nm
1.5
4
1
2.5
M3.5
0.8
16
5
10
3
6
3
A
KA
0.7
1.5
0.7
1.5
M3
0.5
3
7.5
7.5
0.55
2.2
5.5
5.5
1.8
3
0.37
1.5
3
-
1
2.2
0.25
0.8
1.5
-
KW
KW
KW
KW
KW
KW
KW
A
V
V
kV
A
S16
TP16
16
690
415
6
20
S10
TP10
10
440
250
4
12
S6
TP6
6
440
250
4
8
UNIT
RT20
20
690
415
6
25
3
7.5
7.5
0.55
2.2
5.5
5.5
20
5
20
20
1.5
4
1
2.5
M3.5
0.8
RT16
16
690
415
6
20
3
7.5
7.5
0.55
2.2
5.5
5.5
16
5
16
16
1.5
4
1
2.5
M3.5
0.8
Note :-
120V
240V
120V
240V
480V
600V
S10
10
300
0.33
0.75
1
1
-
S6
6
300
0.25
0.5
0.75
1
-
Unit
A
V
HP
HP
HP
HP
HP
HP
3 Phase
Ampere Rating
Operational Voltage
HP Rating
1 Phase
AC Rating Code
CSA / UL RATINGS
15
300
0.33
1
1
2
-
S16
TP16
RT16
20
440
0.33
1
1
2
-
RT20
20
600
1
3
2
5
10
15
S25
TP25
RT25
30
600
1
3
2
5
10
15
S32
TP32
RT32
70
600
10
20
40
50
40
600
2
5
5
10
20
24
55
600
3
7.5
7.5
15
30
40
S80
S40
S63
RT40 RT63
Switch Life (Under standard Operating conditions) Mechanical Life : 1 lac Operations @ 300 cycles / hour
Electrical Life : 10,000 Operations at 100 % Rated duty at 120 cycles / hour
AC RATING CODE
S200
175
600
20
25
50
50
S125
125
600
15
25
50
50
S100
95
600
15
25
50
50
US
US
Indian
: IS 13947-1/3/5, 1993
North
CSA 22.2 No.14-1991
American : UL 508 (1994)
10
50
10
35
2xM5
2.5
10
35
10
25
2xM5
2.5
6
25
6
16
2xM5
2.5
4
16
2.5
10
M5
2
2.5
10
2.5
6
M5
2
2.5
6
1.5
4
M4
1.2
1.5
4
1
2.5
M4
1.2
160
160
125
125
100
100
80
80
63
63
40
40
32
32
25
25
10
70
10
50
M10
2.5
200
25
125
25
100
25
80
25
63
20
40
20
32
10
25
10
37
55
45
22
45
45
31
45
41
8.3
17.2
37
37
30
41
37
22
33
33
22
33
30
18.5
22
22
15
22
22
3
15
18.5
18.5
11
18.5
18.5
2.5
7.5
15
15
7.5
15
15
2.2
5.5
11
11
200
690
690
6
225
125
690
690
6
150
100
690
690
6
125
80
690
690
6
100
5.5
11
11
1.5
4
7.5
7.5
S200
S125
S100
S80
S63
RT63
63
690
500
6
80
S40
RT40
40
690
500
6
50
S32
RT32
32
690
415
6
40
S25
RT25
25
690
415
6
32
20
140
20
100
M10
4
250
250
400
50
320
690
690
6
425
S400
TECHNICAL SPECIFICATION
INSTALLATION PROCEDURE
29
DC SWITCHES
Features
INTRODUCTION
CAM OPERATED ROTARY SWITCHES are defined as set of contacts arranged to
make and break in a sequential fashion by which the connected outputs will either
close or open the circuits.
Applications
CPRI Tested.
170PCD
D100 - D500
236.00
The main areas of operation are in making, breaking and isolation of power circuits and
switching of auxiliary circuits.
The Cam which does the function of closing & opening of the contacts have multiple
positions ( Rotary Movement) which allows multiple circuit functions controlled through
a single operation.
24
Another advantage, which can be derived, is the flexibility in the Contact block selection,
which gives the user the option to select the number of contacts as per his requirement.
The choice also covers the rating of the applicable Operational Duty. This will ensure
that the right switch is chosen for the application. CAM operated rotary switches also
offers design flexibility to assemble complex switching programmes to customize any
switching application.
The basic operating mechanism of these switches depends on the type of application.
Quick-Make, Quick-Make-Quick-Break and Spring return operating mechanisms can be
chosen.
Usage of high quality engineering materials for various components ensure that the
switches have long life with higher degree of Electrical and Mechanical endurance.
Double Butt contacts with silver bimetal on copper ensure better making and breaking
over conventional knife-edge switches. Usage of high-grade engineering plastics like
Nylon and Celcon for the components and glass filled polyamide construction provides
greater mechanical strength to the switches.
These Cam operated rotary switches have versatile mounting options to suit any kind
of application. Special mounting options like single hole, door interlocking and padlocking
are also available.
0.8
1.5
3.1
1.5
138.5
DESCRIPTION
DUTY RATING - DC 22A L/R 2M sec
Operational Voltage
Voltage for AC Rating
Operational Current
Thermal Current ? I th ?
Switching Angle
Maximum Contact Stages
UNIT
D100
D200
D300
D400
D500
VDC
VAC
A
A
Deg
250
460
100
125
90
9
250
460
200
250
90
9
250
460
300
375
90
9
250
460
400
500
90
9
250
460
500
625
90
9
170PCD
1
The enclosed sheets will give an indepth view into the various types of switches,
Mountings, Switching Programmes, Optional Accessories and the Ordering procedure
for CAM OPERATED ROTARY SWITCH.
236.00
1.5
L
0.8
1.5
3.1
138.5
31