Академический Документы
Профессиональный Документы
Культура Документы
ALARM
January 2006
KEYPAD MENUS
CONTENTS
1 ALARM
2 STATUS
3 PERFORMANCE
4 MEASUREMENT
KEYS
CONTINUES
Constellation
TRIB
(DS1/E1) A,B
LOCK ACTIVE
MODEM A, B IF LPBK
OC3 LPBK
OC3 LPBK BY REMOTE
OC3 REMOTE LPBK
DS3 LPBK
DS3 1,2,3,4 LOOPBACK
DS3-1,2,3,4 LPBK BY REMOT
DS3-1,2,3,4 REMOTE LPBK
5 CONTROL
6 CONTROL SUBMENU
7 CONFIG (CONFIGURATION)
8 CUSTOM CONFIG
KEYPAD
8
2
4
6
5
ENTER
0 to 9
F1 to F4
CONTROL
ACTIVE
FUNCTION
Scroll up
Scroll down
Page up
Page down
HOME
Enter a menu/
execute commands
Numeric keys
Function keys
SYSTEM
ALARMS
TRAFFIC A
TRAFFIC B
PATH A, B
DS3
RECEIVE
LOCAL CLOCK
HLM-1, 2
TRANSMIT
RECEIVE
WAYSIDE
CONTINUES
M12
CARRIER LOSS B
FEC LOCK B
SYNC LOSS B
RMT SYNC LOSS B
SIGNAL DEGRADED B
ONLINE DS3-1,2,3,4
TRANSMIT
CARRIER LOSS A
FEC LOCK A
SYNC LOSS A
OC3 RX LOF
RMT SYNC LOSS A
SIGNAL DEGRADED A
* This message is
displayed when
there are no alarms.
INPUT LOS
OUTPUT FAIL
BIPOLAR VIOLATION
INPUT LOS
AIS INPUT
AIS RECEIVED
OUTPUT FAIL
INPUT LOS
OUTPUT FAIL
RX LOF
BIPOLAR VIOLATION
NO ALARMS*
CONFIG ALM
NO ETHERNET ADDRESS
M12 FILLER MISSING
FAN A1, A2 ALARM
FAN B1, B2 ALARM
FUSE ALARM
TX-A, TX-B, ATPC-BOOST**
EXTERNAL 1 ... 8 ALARM
SYSTEM IS REBOOTING
CARD(S) NOT UPDATED
MODEM-A1, A2
MODEM-B1, B2
TRANSMIT
RECEIVE
RX-A1, A2
RX-B1, B2
CONTINUES
WS LPBK ACTIVE
CARD
ABSENT
1 ALARM
INPUT LOS
BIPOLAR VIOLATION
AIS INPUT
AIS RECEIVED
OUTPUT FAIL
TRIB LPBK BY REMOT
SYNTH LOCK
AGC
WRONG RX OPTION
WS LOOPBACK
WS LPBK BY REMOTE
WS REMOTE LPBK
TX TO HLM-1, 2 ALM
T2 SYNC LOSS
T1 LOCAL CLK
TRIB 1... 4 OUTPUT FAIL
DS3 1,2,3,4 INPUT LOS
OC3 INPUT LOS
TX LOSS OF FRAME
TX TO MODEM-A1, A2
TX TO MODEM-B1, B2
DS3 1,2,3,4 BPV
M12-1 ... 8 TX CLK
M12-STBY TX CLK
TX SYNC LOSS A
DS3 OUTPUT FAIL
DS3 1,2,3,4 OUTPUT FAIL
SYNC LOSS A, B
M13 SYNC LOSS
RX LOSS OF FRAME
WS RX LOF
WS OUTPUT FAIL
ALIGNMENT A,B
M12-1 ... 8 RX CLK
M12-STBY RX CLK
TX ENCODER
TX LEVEL
CARRIER LOSS
FEC LOCK
RX DECODER
DEMOD
ALARM
CONTINUES
TX-A1, A2
TX-B1, B2
PS-A1, A2
PS-B1, B2
svc
2 STATUS
ON LINE
EQUIPMENT
PERFORMANCE
SYNTH LOCK
MANUAL MUTE
OUTPUT POWER LOW
NO IF INPUT
LOSS OF -12V
WRONG TX OPTION
CONTINUES
RELAYS
LATCH ERR
SEC
ET
UNAV
AV
EFS
ES
SES
EFSR
ESR
SESR
UNAVR
TRIBUTARY
A1...A28 BER
XXX
XXXXXXX
XXd XXh XX:XX
RUN/STOP
XXX
XXXXXXX
XXd XXh XX:XX
RUN/STOP
TRIBUTARY
B1...B16 BER
SYNC LOSS A, B
PROTECTED M12
ON LINE HLM
ON LINE MOD/TX A
ON LINE MOD/TX B
ON LINE DEMOD/RX A
ON LINE DEMOD/RX B
X
X
X
X
X
X
1/.../8/NONE
1/2
1/2
1/2
1/2
1/2
XXXXXX 8xDS1/16xDS1/
28xDS1/24xE1/
1xDS3/3xDS3/
4xDS3/155MBIT
3DS3 CAPACITY USE XXXXXXXXXXXXXXXXXX T3-1, T3-2, T3-3/
T2 ADM, T3-2, T3-3/
T3-1, T2 ADM, T3-3/
T3-1, T3-2, T2 ADM/
28 T1, T3-2, T3-3/
T3-1, 28 T1, T3-3/
T3-1, T3-2, 28 T1
USED CAPACITY
XXXXXXX 4xTRIB/8xTRIB/
12xTRIB/16xTRIB/
20xTRIB/24xTRIB/
28xTRIB
MODE
XXXXXXXX TERMINAL/REPEATER
TRIB I/F
XXXXXXXXXX ELECTRICAL/OPTICAL
TX-A1, A2 PWR
XXXdBm
TX-B1, B2 PWR
XXXdBm
RSL A1, A2
XXXdBm
XXXdBm
RSL B1, B2
TX-A1, A2 TEMP*
XXX C
TX-B1, B2 TEMP*
XXX C
XXX SET/CLR
RCS SW A1 TO A2
RCS SW A2 TO A1
XXX SET/CLR
RCS SW BI TO B2
XXX SET/CLR
XXX SET/CLR
RCS SW B2 TO B1
RELAY 1 ... RELAY 8
CONTROLLER
INVENTORY
EXEC
XXd XXh XX:XX
XXd XXh XX:XX
XXd XXh XX:XX
XXXXXXXX
XXXXXXXX
XXXXXXXX
XXXXXXXX
XXXXXXXX
XXXXXXXX
XXXXXXXX
ERR SEC
+10.5V PA
+10.5V
-12V
+12V
+5V
MAX CAPACITY
SYSTEM
RESET STATISTIC
ET
UNAV
AV
EFS
ES
SES
EFSR
ESR
SESR
UNAVR
M12-1 ... 8
M12-STBY
HLM-1, 2
MODEM-A1, A2
MODEM-B1, B2
TX-A1, A2
TX-B1, B2
RX-A1, A2
RX-B1, B2
PS-A1, A2
PS-B1, B2
SVC
XXX
S/W VER
BOOT VER
PN
SN
REVISION
DATE
4 MEASUREMENT
MEASUREMENT
XXX
CBER A, B
XXXXXXX
UBER A1, A2
XXXXXXX
UBER B1, B2
XXXXXXX
TIME
XXd XXh XX:XX
5 CONTROL
LOCK/IF LPBK
SET/CLR
XXXX
XXXX
XXX-XXXXXX-XXX
XXXXXXXX
XX
XX-XX-XXXX
S/W VER
XXXX
PN
XXX-XXXXXX-XXX
SN
XXXXXXXX
REVISION
XX
DATE
XX-XX-XXXX
* Temperature reading on the Keypad will
be typically 450C to 550C at ambient
temperature of 250C.
TRIB
LOOPBACK
TRIB REMOTE
LPBK
CONTINUES
MEASUREMENT
CBER A
CBER B
TIME
XXX
XXXXXXX
XXXXXXX
XXd XXh XX:XX
RUN/STOP
XXX SET/CLR
EXEC
XXX SET/CLR
XXX SET/CLR
XXX SET/CLR
XXX SET/CLR
XXX SET/CLR
XXX SET/CLR
EXEC
CLR
CLR
EXEC
CLR
CLR
DS3 LPBK
TRIB A1 ... A28 LPBK
TRIB B1 ... B16 LPBK
XXX
XXX
XXX
SET/CLR
SET/CLR
SET/CLR
SET/CLR
XXX SET/CLR
SET/CLR
XXX SET/CLR
3 PERFORMANCE
SYSTEM BER
RUN/STOP
CONTINUES
CONTROL
CONFIG
CONTINUES
WAYSIDE
LPBK
RELAYS
SERVICE
CHANNEL
ALTERNATE
S/W
CONTINUES
SET/CLR
SET/CLR
XXX
XXX
WAYSIDE LPBK
WAYSIDE RMT LPBK
RELAY 1 ... 8
XXX
SET/CLR
DATA/VF A, B
XXX
MUTE/ON
S/W VER
ALTERN S/W VER
RUN ALTERNATE S/W
XXXX
XXXX
SNMP
EXEC
6 CONTROL SUBMENU
OC3 LPBK
OC3 RMT LPBK
DS3-1, 2, 3, 4 LPBK
DS3-1, 2, 3, 4 REM LPBK
XXX
XXX
XXX
XXX
DISABLE
TRAPS
WARNING!
These commands may
interrupt traffic.
See instruct manual.
7 CONFIG
SYSTEM
M12-1/5 T2 ADD/DRP
M12-1/5 DROP&CONT***
M12-2/6 T2 ADD/DRP
M12-2/6 DROP&CONT***
M12-3/7 T2 ADD/DRP
M12-3/7 DROP&CONT***
M12-4/8 T2 ADD/DRP
M12-4/8 DROP&CONT***
M12-1 ... 4 T2 ADD/DRP
ADM
NETWORK
MANAGEMENT
NONE/T2-1/.../T2-7
DROP&CONT***/DROP A/DROP B
NONE/T2-1/.../T2-7
DROP&CONT***/DROP A/DROP B
NONE/T2-1/.../T2-7
DROP&CONT***/DROP A/DROP B
NONE/T2-1/.../T2-7
DROP&CONT***/DROP A/DROP B
None/T2-1 .../T2-7
IP ROUTING
NETWORK
MANAGEMENT
COMM PORT
SETTINGS
XXX.XXX.XXX.XXX
XXX.XXX.XXX.XXX
ALL TRAPS
SYSTEM ALARM TRAPS
CONF ALM TRAP
FUSE TRAP
EXTERNAL ALM TRAP
ABSENT TRAP
MANAGED TRAP
PS ALM TRAP
TX HIGH PWR ALM TRAP
TX MAN MUTE ALM TRAP
TX SYNTH TRAP
TX ALC TRAP
TX FAN ALM TRAP
RX RSL ALM TRAP
RX SYNTH TRAP
RX AGC ALM TRAP
ONLINE MDM CARRIER
ONLINE MDM FEC LOCK
MODEM TX TRAP
MODEM RX TRAP
MODEM RX EQM TRAP
MODEM UBER ALM TRAP
HLM RX TRAP
HLM SYNC TRAP
HLM RX LOF TRAP
HLM RX AIS TRAP
HLM DS3 OUT TRAP
HLM ALIGN TRAP
HLM TX TRAP
HLM TX LOF TRAP
HLM LOS TRAP
DS3 LOS ALM TRAP
DS3 BPV ALM TRAP
M12 MISSING TRAP
M12 STBY ONLINE TRAP
M12 RX TRAP
M12 TX TRAP
M12 SYNC TRAP
OUT ALM TRAP
LOS ALM TRAP
BPV ALM TRAP
AIS INPUT ALM TRAP
RX AIS ALM TRAP
RX REM LPBK ALM
WAYSIDE ALM TRAP
SVC SYNC TRAP
ENABLE
VERSAT BAUD
VERSAT PARITY
VERSAT DRIVER
MONITOR BAUD
1200/2400/4800/9600
NONE/ODD/EVEN
RS-232/RS-423
1200/2400/4800/9600/19200/
38400/57600
MONITOR PARITY NONE/ODD/EVEN
FARSCAN BAUD
1200/2400/4800/9600/19200/
38400/57600
FARSCAN PARITY NONE/ODD/EVEN
REBOOT SYSTEM
NO/YES
DS3-1, 2, 3, 4 INPUT ALARMS
TRIB A1 ... A28
TRIB B1 ... B16
WAYSIDE
ENABLE/DISABLE
ENABLE/DISABLE
ENABLE/DISABLE
ENABLE/DISABLE
TRIBUTARIES
CONTINUES
DISABLE/ENABLE
MANAGER 1 IP ADDR
.
.
.
MANAGER 10 IP ADDR
RD/WR COMMUNITY
RD ONLY COMMUNITY
TRAP DEST 1 IP ADDR
.
.
.
TRAP DEST 10 IP ADDR
CODE
CONTINUES
AMI/B8ZS, HDB3
AMI/B8ZS, HDB3
AMI/ B8ZS
AMI/B8ZS, HDB3
8 CUSTOM CONFIG
WARNING!
These commands may
interrupt traffic.
See instruct manual.
These commands
also have a value
configuration box.
XXXXXXXX
XXXXXXXX
UP/DOWN
24Hour
UP/DOWN
COARSE
FINE
COARSE
FINE
UP/DOWN
UP/DOWN
UP/DOWN
UP/DOWN
TECHNICAL
SUPPORT
XXXXXXXX
XXXXXXXX
HIGH PWR CALIB dBm
KEYPAD
UP/DOWN
UP/DOWN
FANS
STANDBY
FILLER
M12 #7
M12 #6
M12 #5
M12 #4
M12 #3
M12 #2
M12 #1
RECEIVER A2
NOTE:
POWER SUPPLY A2
000-999
LINEAR/LPMASTER/LP SLAVE
-16 / 7dBm or 0 / 0dBm
0 / 0dBm or 7 / -16dBm
ISOLATE/BRIDGE
DISABLE/ENABLE
DISABLE/ENABLE
SAMPLE/9600/19200/38400
ENABLE/DISABLE
TRANSMITTER A2
SERVICE
CHANNEL
ADDRESS
MODE
VF PORT 1 LEVEL
VF PORT 2 LEVEL
DATA BRIDGE
LOCAL OFF HOOK
EXTERNAL PILOT
DATA PORT A, B BAUD
DATA PORT A, B PARITY
ACU
RECEIVER A1
RELAYS
TRANSMITTER A1
FUSE PANEL
POWER SUPPLY A1
TRIBUTARIES
LAYOUT
(HOT STANDBY TERMINAL - 28 DS1)
DS3 EQUALIZER
0-120'/120'-450'
DS3 1,2,3,4 EQUALIZER
0-120'/120'-450'
TRIB A1...A28 EQUALIZER 0-133'/133'-266'/266'-399'/399'-533'/
533'-655'/E1
TRIB B1...B16 EQUALIZER 0-133'/133'-266'/266'-399'/399'-533'/
533'-655'/E1
WAYSIDE EQUALIZER
0-133'/133'-266'/266'-399'/
399'-533'/533'-655'
E1 UNBALANCED/
E1 BALANCED
EQUALIZER
CONTINUES
MODEM A1
MODEM A2
CONFIG
COARSE
FINE
UP/DOWN
UP/DOWN
COARSE
FINE
UP/DOWN
UP/DOWN
XX
XX
XXX
USA OFFICE
CANADA OFFICE
TEL 1-800-227-8332
(+1) 650-594-3800
FAX 1-650-594-3621
crcusa@harris.com
TEL 1-800-227-8332
(+1) 514-421-8333
FAX (+1) 514- 685-4580
crcmtl@harris.com
http://www.microwave.harris.com/cservice/
7