Вы находитесь на странице: 1из 4

QRC-112873-E17

ALARM

January 2006

KEYPAD MENUS
CONTENTS

1 ALARM
2 STATUS
3 PERFORMANCE
4 MEASUREMENT

KEYS

CONTINUES

Constellation

TRIB
(DS1/E1) A,B

Software Version 6.5 or Higher

LOCK ACTIVE
MODEM A, B IF LPBK
OC3 LPBK
OC3 LPBK BY REMOTE
OC3 REMOTE LPBK
DS3 LPBK
DS3 1,2,3,4 LOOPBACK
DS3-1,2,3,4 LPBK BY REMOT
DS3-1,2,3,4 REMOTE LPBK

5 CONTROL
6 CONTROL SUBMENU
7 CONFIG (CONFIGURATION)
8 CUSTOM CONFIG

KEYPAD
8
2
4
6
5
ENTER
0 to 9
F1 to F4

CONTROL
ACTIVE

FUNCTION
Scroll up
Scroll down
Page up
Page down
HOME
Enter a menu/
execute commands
Numeric keys
Function keys

SYSTEM
ALARMS

TRAFFIC A

TRAFFIC B

PATH A, B

** ATPC is enabled, and


Transmitter power is
being boosted.

DS3

TRIB LPBK ACTIVE B

TRIB B1 ... B16 LPBK

TRIB REMOTE LPBK A

TRIB A1 ... A28 RMT LPBK

TRIB REMOTE LPBK B

TRIB B1 ... B16 RMT LPBK

M12-1 ... 8 ABSENT


M12-STBY ABSENT
HLM-1, 2 ABSENT
MODEM-A1, A2 ABSENT
MODEM-B1, B2 ABSENT
RX-A1, A2 ABSENT
RX-B1, B2 ABSENT
TX-A1, A2 ABSENT
TX-B1, B2 ABSENT
PS-A1, A2 ABSENT
PS-B1, B2 ABSENT
SVC ABSENT
M12-1... M12-8
M12-STBY

RECEIVE

LOCAL CLOCK

HLM-1, 2

TRANSMIT

RECEIVE

RSL A1, A2 / B1, B2 LOW


SIGNAL DEGRADED A1,A2
SIGNAL DEGRADED B1,B2
ONLINE ALIGNMENT A, B

WAYSIDE
CONTINUES

M12

CARRIER LOSS B
FEC LOCK B
SYNC LOSS B
RMT SYNC LOSS B
SIGNAL DEGRADED B

ONLINE DS3-1,2,3,4

TRIB A1 ... A28 LPBK

TRANSMIT

CARRIER LOSS A
FEC LOCK A
SYNC LOSS A
OC3 RX LOF
RMT SYNC LOSS A
SIGNAL DEGRADED A

OC3 INPUT LOS


OC3 TX LOF
TRIB
(OC3/DS3/WS)

* This message is
displayed when
there are no alarms.

INPUT LOS
OUTPUT FAIL
BIPOLAR VIOLATION
INPUT LOS
AIS INPUT
AIS RECEIVED
OUTPUT FAIL
INPUT LOS
OUTPUT FAIL
RX LOF
BIPOLAR VIOLATION

Copyright 2003, Harris Corporation

NO ALARMS*

CONFIG ALM
NO ETHERNET ADDRESS
M12 FILLER MISSING
FAN A1, A2 ALARM
FAN B1, B2 ALARM
FUSE ALARM
TX-A, TX-B, ATPC-BOOST**
EXTERNAL 1 ... 8 ALARM
SYSTEM IS REBOOTING
CARD(S) NOT UPDATED

MODEM-A1, A2
MODEM-B1, B2

TRANSMIT
RECEIVE

RX-A1, A2
RX-B1, B2
CONTINUES

PROTECT M12-1 ... M12-8


LOCK HLM-1
LOCK HLM-2
LOCK MOD /TX A1
LOCK MOD /TX A2
LOCK MOD /TX B1
LOCK MOD /TX B2
LOCK DMOD /RX A1
LOCK DMOD /RX A2
LOCK DMOD /RX B1
LOCK DMOD /RX B2

TRIB LPBK ACTIVE A

WS LPBK ACTIVE

CARD
ABSENT

1 ALARM

TRIBUTARY A1 ... A28


TRIBUTARY B1 ... B16

INPUT LOS
BIPOLAR VIOLATION
AIS INPUT
AIS RECEIVED
OUTPUT FAIL
TRIB LPBK BY REMOT

SYNTH LOCK
AGC
WRONG RX OPTION

WS LOOPBACK
WS LPBK BY REMOTE
WS REMOTE LPBK

TX TO HLM-1, 2 ALM
T2 SYNC LOSS
T1 LOCAL CLK
TRIB 1... 4 OUTPUT FAIL
DS3 1,2,3,4 INPUT LOS
OC3 INPUT LOS
TX LOSS OF FRAME
TX TO MODEM-A1, A2
TX TO MODEM-B1, B2
DS3 1,2,3,4 BPV
M12-1 ... 8 TX CLK
M12-STBY TX CLK
TX SYNC LOSS A
DS3 OUTPUT FAIL
DS3 1,2,3,4 OUTPUT FAIL
SYNC LOSS A, B
M13 SYNC LOSS
RX LOSS OF FRAME
WS RX LOF
WS OUTPUT FAIL
ALIGNMENT A,B
M12-1 ... 8 RX CLK
M12-STBY RX CLK
TX ENCODER
TX LEVEL
CARRIER LOSS
FEC LOCK
RX DECODER
DEMOD

ALARM
CONTINUES

TX-A1, A2
TX-B1, B2

PS-A1, A2
PS-B1, B2

svc

2 STATUS
ON LINE
EQUIPMENT

PERFORMANCE

SYNTH LOCK
MANUAL MUTE
OUTPUT POWER LOW
NO IF INPUT
LOSS OF -12V
WRONG TX OPTION

CONTINUES

RELAYS

LATCH ERR
SEC

ET
UNAV
AV
EFS
ES
SES
EFSR
ESR
SESR
UNAVR

XXd XXh XX:XX


XXd XXh XX:XX
XXd XXh XX:XX
XXXXXXXX
XXXXXXXX
XXXXXXXX
XXXXXXXX
XXXXXXXX
XXXXXXXX
XXXXXXXX

TRIBUTARY
A1...A28 BER

TRIB A1...A28 GEN


TRIB A1...A28 BER
TIME

XXX
XXXXXXX
XXd XXh XX:XX

RUN/STOP

TRIB B1...B16 GEN


TRIB B1...B16 BER
TIME

XXX
XXXXXXX
XXd XXh XX:XX

RUN/STOP

TRIBUTARY
B1...B16 BER

SYNC LOSS A, B

PROTECTED M12
ON LINE HLM
ON LINE MOD/TX A
ON LINE MOD/TX B
ON LINE DEMOD/RX A
ON LINE DEMOD/RX B

X
X
X
X
X
X

1/.../8/NONE
1/2
1/2
1/2
1/2
1/2

XXXXXX 8xDS1/16xDS1/
28xDS1/24xE1/
1xDS3/3xDS3/
4xDS3/155MBIT
3DS3 CAPACITY USE XXXXXXXXXXXXXXXXXX T3-1, T3-2, T3-3/
T2 ADM, T3-2, T3-3/
T3-1, T2 ADM, T3-3/
T3-1, T3-2, T2 ADM/
28 T1, T3-2, T3-3/
T3-1, 28 T1, T3-3/
T3-1, T3-2, 28 T1
USED CAPACITY
XXXXXXX 4xTRIB/8xTRIB/
12xTRIB/16xTRIB/
20xTRIB/24xTRIB/
28xTRIB
MODE
XXXXXXXX TERMINAL/REPEATER
TRIB I/F
XXXXXXXXXX ELECTRICAL/OPTICAL
TX-A1, A2 PWR
XXXdBm
TX-B1, B2 PWR
XXXdBm
RSL A1, A2
XXXdBm
XXXdBm
RSL B1, B2
TX-A1, A2 TEMP*
XXX C
TX-B1, B2 TEMP*
XXX C
XXX SET/CLR
RCS SW A1 TO A2
RCS SW A2 TO A1
XXX SET/CLR
RCS SW BI TO B2
XXX SET/CLR
XXX SET/CLR
RCS SW B2 TO B1
RELAY 1 ... RELAY 8
CONTROLLER

INVENTORY

EXEC
XXd XXh XX:XX
XXd XXh XX:XX
XXd XXh XX:XX
XXXXXXXX
XXXXXXXX
XXXXXXXX
XXXXXXXX
XXXXXXXX
XXXXXXXX
XXXXXXXX

ERR SEC

+10.5V PA
+10.5V
-12V
+12V
+5V

MAX CAPACITY

SYSTEM

RESET STATISTIC
ET
UNAV
AV
EFS
ES
SES
EFSR
ESR
SESR
UNAVR

M12-1 ... 8
M12-STBY
HLM-1, 2
MODEM-A1, A2
MODEM-B1, B2
TX-A1, A2
TX-B1, B2
RX-A1, A2
RX-B1, B2
PS-A1, A2
PS-B1, B2
SVC

XXX
S/W VER
BOOT VER
PN
SN
REVISION
DATE

See "4 Measurement" to access


Hidden Submenu.

4 MEASUREMENT
MEASUREMENT
XXX
CBER A, B
XXXXXXX
UBER A1, A2
XXXXXXX
UBER B1, B2
XXXXXXX
TIME
XXd XXh XX:XX

5 CONTROL
LOCK/IF LPBK

SET/CLR
XXXX
XXXX
XXX-XXXXXX-XXX
XXXXXXXX
XX
XX-XX-XXXX

S/W VER
XXXX
PN
XXX-XXXXXX-XXX
SN
XXXXXXXX
REVISION
XX
DATE
XX-XX-XXXX
* Temperature reading on the Keypad will
be typically 450C to 550C at ambient
temperature of 250C.

TRIB
LOOPBACK
TRIB REMOTE
LPBK

CONTINUES

MEASUREMENT
CBER A
CBER B
TIME

XXX
XXXXXXX
XXXXXXX
XXd XXh XX:XX

RUN/STOP

PROTECT M12-1 ... M12-8


RELEASE STBY
LOCK HLM-1, 2*
LOCK MOD/TX-A1, A2*
LOCK MOD/TX-B1, B2*
LOCK DMOD/RX-A1, A2*
LOCK DMOD/RX-B1, B2*
MODEM A, B IF LPBK
SWITCH MOD/TX-A **
RCS SW A1 TO A2 ***
RCS SW A2 TO A1 ***
SWITCH MOD/TX-B **
RCS SW B1 TO B2 ***
RCS SW B2 TO B1 ***

XXX SET/CLR
EXEC
XXX SET/CLR
XXX SET/CLR
XXX SET/CLR
XXX SET/CLR
XXX SET/CLR
XXX SET/CLR
EXEC
CLR
CLR
EXEC
CLR
CLR

DS3 LPBK
TRIB A1 ... A28 LPBK
TRIB B1 ... B16 LPBK

XXX
XXX
XXX

TRIB A1 ... A28 RMT LPBK


TRIB B1 ... B16 RMT LPBK

SET/CLR
SET/CLR
SET/CLR

SET/CLR
XXX SET/CLR
SET/CLR
XXX SET/CLR

* The LOCK commands can be potentially traffic affecting. For the


module that you plan on locking to, check the status of the module for
alarms before locally or remotely executing a LOCK command. This
will prevent you from locking on to a defective module.

3 PERFORMANCE
SYSTEM BER

To access the hidden measurement menu:


Keypad: F1+F3 VT100: Ctrl+B

RUN/STOP

CONTINUES

** The SWITCH MOD/TX command can be executed only if there are no


alarms on the off-line Transmitter.
*** If executing the SWITCH MOD/TX command causes a Remote Sync
alarm (RCS switch alarm), the command to Clear the RCS switch
appears on the screen.

CONTROL

CONFIG

CONTINUES

WAYSIDE
LPBK
RELAYS
SERVICE
CHANNEL
ALTERNATE
S/W

CONTINUES

SET/CLR
SET/CLR

XXX
XXX

WAYSIDE LPBK
WAYSIDE RMT LPBK
RELAY 1 ... 8

XXX

SET/CLR

DATA/VF A, B

XXX

MUTE/ON

S/W VER
ALTERN S/W VER
RUN ALTERNATE S/W

XXXX
XXXX

NETCOM OVER ETHERNET

SNMP

TRAP TIMEOUT (SEC)


TRAP REPEAT
TRAP COMMUNITY

EXEC

See "6 Control Submenu" to access


Hidden Submenu.

6 CONTROL SUBMENU
OC3 LPBK
OC3 RMT LPBK
DS3-1, 2, 3, 4 LPBK
DS3-1, 2, 3, 4 REM LPBK

XXX
XXX
XXX
XXX

DISABLE
TRAPS

To access the hidden measurement menu:


Keypad: F1+F3
VT100: Ctrl+B
SET/CLR
SET/CLR
SET/CLR
SET/CLR

WARNING!
These commands may
interrupt traffic.
See instruct manual.

T3-1, T3-2, T3-3/T2 ADM,T3-2, T3,3/


T3-1, T2 ADM, T3-3/ T3-1, T3-2, T2 ADM/
28T1, T3-2, T3-3/ T3-1, 28T1, T3-3/
T3-1, T3-2, 28T1
4xTRIB/8xTRIB/12xTRIB/16xTRIB/
USED CAPACITY
20xTRIB/24xTRIB/28xTRIB
UNPROT/UNPR TX/MHSB/FREQ DIV/
PROTECTION A, B
RX & M12/M12 ONLY/
HLM UNPROTECTED/MAY PROTECT HLM
HLM PROTECTION
0-20 sec
RCS DELAY (SEC)
SYNCHRONIZATION MX THRU TIMED/SOURCE
M13/C-BIT PARITY
STUFFING MODE
DISABLE HIGH/ DISABLE LOW/ENABLE
TX-A, B ATPC **
NON REV/REVERTIVE
M12 PROTECTION
INSTALL/UNINSTALL
SVC OPTION
INSTALL/UNINSTALL
FAN OPTION
PATH A, B ALARMS MENU HIDE/SHOW
CLR/SET
CONFIG ALARM

7 CONFIG

3DS3 CAPACITY USE*

SYSTEM

M12-1/5 T2 ADD/DRP
M12-1/5 DROP&CONT***
M12-2/6 T2 ADD/DRP
M12-2/6 DROP&CONT***
M12-3/7 T2 ADD/DRP
M12-3/7 DROP&CONT***
M12-4/8 T2 ADD/DRP
M12-4/8 DROP&CONT***
M12-1 ... 4 T2 ADD/DRP

ADM

NETWORK
MANAGEMENT

NONE/T2-1/.../T2-7
DROP&CONT***/DROP A/DROP B
NONE/T2-1/.../T2-7
DROP&CONT***/DROP A/DROP B
NONE/T2-1/.../T2-7
DROP&CONT***/DROP A/DROP B
NONE/T2-1/.../T2-7
DROP&CONT***/DROP A/DROP B
None/T2-1 .../T2-7

NE ADDRESS 001 ... 999

IP ROUTING
NETWORK
MANAGEMENT

AUX PORT CONFIG


NETCOM/ETHERNET/
NONE
NETCOM IP INTERFACE DISABLE/ENABLE
XXX.XXX.XXX.XXX
NETCOM IP ADDRESS
XXX.XXX.XXX.XXX
NETCOM IP MASK
ETHERNET IP INTERFACE DISABLE/ENABLE
ETHERNET IP ADDRESS XXX.XXX.XXX.XXX
XXX.XXX.XXX.XXX
ETHERNET IP MASK
RIP
DISABLE/VER 1/
VER 2/VER 1&2
DISABLE/ENABLE
RIP ON NETCOM IF
DISABLE/ENABLE
RIP ON ETHENET IF
IP ROUTE 1 ADDRESS
XXX.XXX.XXX.XXX
XXX.XXX.XXX.XXX
IP ROUTE MASK1
XXX.XXX.XXX.XXX
NEXT IP ROUTER 1
.
.
.
IP ROUTE 7 ADDRESS
XXX.XXX.XXX.XXX
XXX.XXX.XXX.XXX
IP ROUTE MASK 7
NEXT IP ROUTER 7
XXX.XXX.XXX.XXX

COMM PORT
SETTINGS

XXX.XXX.XXX.XXX
XXX.XXX.XXX.XXX

Editable only from an SNMP


interface such as StarView.
XXX.XXX.XXX.XXX
XXX.XXX.XXX.XXX
XXX
XXX
Constellation

ALL TRAPS
SYSTEM ALARM TRAPS
CONF ALM TRAP
FUSE TRAP
EXTERNAL ALM TRAP
ABSENT TRAP
MANAGED TRAP
PS ALM TRAP
TX HIGH PWR ALM TRAP
TX MAN MUTE ALM TRAP
TX SYNTH TRAP
TX ALC TRAP
TX FAN ALM TRAP
RX RSL ALM TRAP
RX SYNTH TRAP
RX AGC ALM TRAP
ONLINE MDM CARRIER
ONLINE MDM FEC LOCK
MODEM TX TRAP
MODEM RX TRAP
MODEM RX EQM TRAP
MODEM UBER ALM TRAP
HLM RX TRAP
HLM SYNC TRAP
HLM RX LOF TRAP
HLM RX AIS TRAP
HLM DS3 OUT TRAP
HLM ALIGN TRAP
HLM TX TRAP
HLM TX LOF TRAP
HLM LOS TRAP
DS3 LOS ALM TRAP
DS3 BPV ALM TRAP
M12 MISSING TRAP
M12 STBY ONLINE TRAP
M12 RX TRAP
M12 TX TRAP
M12 SYNC TRAP
OUT ALM TRAP
LOS ALM TRAP
BPV ALM TRAP
AIS INPUT ALM TRAP
RX AIS ALM TRAP
RX REM LPBK ALM
WAYSIDE ALM TRAP
SVC SYNC TRAP

ENABLE

Disable All/CFG individually


ENABLE/DISABLE
ENABLE/DISABLE
ENABLE/DISABLE
ENABLE/DISABLE
ENABLE/DISABLE
ENABLE/DISABLE
ENABLE/DISABLE
ENABLE/DISABLE
ENABLE/DISABLE
ENABLE/DISABLE
ENABLE/DISABLE
ENABLE/DISABLE
ENABLE/DISABLE
ENABLE/DISABLE
ENABLE/DISABLE
ENABLE/DISABLE
ENABLE/DISABLE
ENABLE/DISABLE
ENABLE/DISABLE
ENABLE/DISABLE
ENABLE/DISABLE
ENABLE/DISABLE
ENABLE/DISABLE
ENABLE/DISABLE
ENABLE/DISABLE
ENABLE/DISABLE
ENABLE/DISABLE
ENABLE/DISABLE
ENABLE/DISABLE
ENABLE/DISABLE
ENABLE/DISABLE
ENABLE/DISABLE
ENABLE/DISABLE
ENABLE/DISABLE
ENABLE/DISABLE
ENABLE/DISABLE
ENABLE/DISABLE
ENABLE/DISABLE
ENABLE/DISABLE
ENABLE/DISABLE
ENABLE/DISABLE
ENABLE/DISABLE
ENABLE/DISABLE
ENABLE/DISABLE
ENABLE/DISABLE

VERSAT BAUD
VERSAT PARITY
VERSAT DRIVER
MONITOR BAUD

1200/2400/4800/9600
NONE/ODD/EVEN
RS-232/RS-423
1200/2400/4800/9600/19200/
38400/57600
MONITOR PARITY NONE/ODD/EVEN
FARSCAN BAUD
1200/2400/4800/9600/19200/
38400/57600
FARSCAN PARITY NONE/ODD/EVEN

REBOOT SYSTEM

NO/YES
DS3-1, 2, 3, 4 INPUT ALARMS
TRIB A1 ... A28
TRIB B1 ... B16
WAYSIDE

ENABLE/DISABLE
ENABLE/DISABLE
ENABLE/DISABLE
ENABLE/DISABLE

TRIBUTARIES

CONTINUES

The 3DS3 CAPACITY USE submenu is used for the 4DS3


option as well as the 3DS3 option
** You can select one of the three options:
- DISABLE HIGH: Disable ATPC, set Tx at High power.
- DISABLE LOW: Disable ATPC, set Tx at Low power.
- ENABLE: Enable ATPC.
*** DROP & CONT: Traffic can be dropped from A and B at the
same time.

DISABLE/ENABLE

MANAGER 1 IP ADDR
.
.
.
MANAGER 10 IP ADDR
RD/WR COMMUNITY
RD ONLY COMMUNITY
TRAP DEST 1 IP ADDR
.
.
.
TRAP DEST 10 IP ADDR

CODE
CONTINUES

TRIB A1 ... A28 CODE


TRIB B1 ... B16 CODE
WAYSIDE CODE
WAYSIDE CODE

AMI/B8ZS, HDB3
AMI/B8ZS, HDB3
AMI/ B8ZS
AMI/B8ZS, HDB3

8 CUSTOM CONFIG

WARNING!
These commands may
interrupt traffic.
See instruct manual.

To access custom commands from


the configuration menu: Keypad:
F1+F3 VT100: Ctrl+B
TX-A1,A2 FREQ (KHZ)*
RX-A1,A2 FREQ (KHZ)*

These commands
also have a value
configuration box.

XXXXXXXX
XXXXXXXX
UP/DOWN

ACT: XX.X dBm


NEW: ____________

24Hour

HIGH PWR CALIB


ADJUST LOW PWR

UP/DOWN

LOW PWR CALIB

TX-A1,A2 100MHZ TUNE


RX-A1,A2 100MHZ TUNE

COARSE
FINE
COARSE
FINE

TX-B1,B2 FREQ (KHZ)*


RX-B1,B2 FREQ (KHZ)*

LOW PWR CALIB dBm

ACT: XX.X dBm


NEW: ____________

UP/DOWN
UP/DOWN

UP/DOWN

HIGH PWR CALIB


ADJUST LOW PWR

UP/DOWN

LOW PWR CALIB

RX-B1,B2 100MHZ TUNE


ATPC THRESH LOW DIF**
ATPC THRESH HI DIF***
REFRESH RATE (HRS)+

TECHNICAL
SUPPORT

XXXXXXXX
XXXXXXXX
HIGH PWR CALIB dBm

TX-B1,B2 100MHZ TUNE

KEYPAD

UP/DOWN
UP/DOWN

ADJUST HIGH PWR

TX-B1,B2 PWR CALIB

FANS

HIGH PWR CALIB dBm

ADJUST HIGH PWR


TX-A1,A2 PWR CALIB

STANDBY
FILLER
M12 #7
M12 #6
M12 #5
M12 #4
M12 #3
M12 #2
M12 #1

RECEIVER A2

NOTE:

See "8. Custom Configuration" to access


customized keypad commands.

POWER SUPPLY A2

000-999
LINEAR/LPMASTER/LP SLAVE
-16 / 7dBm or 0 / 0dBm
0 / 0dBm or 7 / -16dBm
ISOLATE/BRIDGE
DISABLE/ENABLE
DISABLE/ENABLE
SAMPLE/9600/19200/38400
ENABLE/DISABLE

TRANSMITTER A2

SERVICE
CHANNEL

ADDRESS
MODE
VF PORT 1 LEVEL
VF PORT 2 LEVEL
DATA BRIDGE
LOCAL OFF HOOK
EXTERNAL PILOT
DATA PORT A, B BAUD
DATA PORT A, B PARITY

ACU

RECEIVER A1

RELAYS

MANUAL CONTROL/ MAJOR ALARM/ MINOR ALARM/


INPUT LOS/ SYNC LOSS A/ SYNC LOSS B/
ERRORED SECOND A/ ERRORED SECOND B/
SIGNAL DEGRAD A1/ SIGNAL DEGRAD A2/
SIGNAL DEGRAD B1/ SIGNAL DEGRAD B2/
ON LINE MOD/ TX A/ ON LINE MOD/ TX B/
ON LINE RXA/ ON LINE RXB/ ON LINE HLM

TRANSMITTER A1

RELAY 1...8 INPUT

FUSE PANEL

POWER SUPPLY A1

TRIBUTARIES

LAYOUT
(HOT STANDBY TERMINAL - 28 DS1)

DS3 EQUALIZER
0-120'/120'-450'
DS3 1,2,3,4 EQUALIZER
0-120'/120'-450'
TRIB A1...A28 EQUALIZER 0-133'/133'-266'/266'-399'/399'-533'/
533'-655'/E1
TRIB B1...B16 EQUALIZER 0-133'/133'-266'/266'-399'/399'-533'/
533'-655'/E1
WAYSIDE EQUALIZER
0-133'/133'-266'/266'-399'/
399'-533'/533'-655'
E1 UNBALANCED/
E1 BALANCED

HIGH LEVEL MUX 1


HIGH LEVEL MUX 2
SPU CONTROLLER
SERVICE CHANNEL

EQUALIZER

CONTINUES

MODEM A1
MODEM A2

CONFIG

COARSE
FINE

UP/DOWN
UP/DOWN

COARSE
FINE

UP/DOWN
UP/DOWN

XX
XX
XXX

ACT: XX.X dBm


NEW: ____________
LOW PWR CALIB dBm

ACT: XX.X dBm


NEW: ____________

* Be sure to enter exactly


7 digits for the frequency.
For 11 GHz systems,
enter 8 digits.
** Default: 5dB
*** Default: 17dB
+This value should be kept
at 3.

USA OFFICE

CANADA OFFICE

TEL 1-800-227-8332
(+1) 650-594-3800
FAX 1-650-594-3621
crcusa@harris.com

TEL 1-800-227-8332
(+1) 514-421-8333
FAX (+1) 514- 685-4580
crcmtl@harris.com

http://www.microwave.harris.com/cservice/
7

Вам также может понравиться