Вы находитесь на странице: 1из 25

11/4/2016

IndianStandard:CODEOFPRACTICEFORSANITARYPIPEWORKABOVEGROUNDFORBUILDINGS

PREAMBLE(NOTPARTOFTHESTANDARD)
Inordertopromotepubliceducationandpublicsafety,equaljusticeforall,abetterinformed
citizenry,theruleoflaw,worldtradeandworldpeace,thislegaldocumentisherebymadeavailableona
noncommercialbasis,asitistherightofallhumanstoknowandspeakthelawsthatgovernthem.
ENDOFPREAMBLE(NOTPARTOFTHESTANDARD)
(Reaffirmed2007)
IS:53291983

IndianStandard
CODEOFPRACTICEFORSANITARYPIPEWORK
ABOVEGROUNDFORBUILDINGS
(FirstRevision)
FirstReprintFEBRUARY1993
UDC69612:6216432:00676
Copyright1984
BUREAUOFINDIANSTANDARDS
MANAKBHAVAN,9BAHADURSHAHZAFARMARG
NEWDELHI110002
Gr7
April1984
i

IndianStandard
CODEOFPRACTICEFORSANITARYPIPEWORKABOVEGROUNDFORBUILDINGS
(FirstRevision)
WaterSupplyandSanitationSectionalCommittee,BDC24
Chairman
ShriJ.DCruz
Members

Representing
WaterSupplyandSewageDisposalUndertaking,NewDelhi

ChiefEngineer(CivilI)(AlternatetoShriJ.DCruz)
Adviser(PHE)

MinistryofWorksandHousing

DeputyAdviser(PHE)(Alternate)
ShriN.S.Bhairavan

PublicHealthEngineeringDepartment,GovernmentofKerala,Trivandrum

SuperintendingEngineer(Alternate)
ShriI.Chandra

PublicWorksDepartment,PublicHealthBranch,GovernmentofHaryana,Chandigarh

ShriK.K.Gandhi(Alternate)
ChiefEngineer

UttarPradeshJalNigam,Lucknow

(Construction)
SuperintendingEngineer(Alternate)
ShriR.C.P.Chaudhary

EngineersIndiaLtd,NewDelhi

ShriH.V.Rao(Alternate)
https://law.resource.org/pub/in/bis/S03/is.5329.1983.html

1/25

11/4/2016

IndianStandard:CODEOFPRACTICEFORSANITARYPIPEWORKABOVEGROUNDFORBUILDINGS

ShriS.K.Dasgupta

CalcuttaMetropolitanDevelopmentAuthority,Calcutta

ShriS.R.Mukherjee(Alternate)
ProfJ.M.Dave

InstitutionofEngineers(India),Calcutta

ShriS.G.Deolalikar

Inpersonalcapacity(FlatNo.403,SavitriCinemaCommercialComplex,GreaterKailash
II,NewDelhi)

ShriB.R.N.Gupta

EngineerinChief'sBranch,ArmyHeadquarters

ShriK.V.Krishnamurthy(Alternate)
HydraulicEngineer

MunicipalCorporationofGreaterBombay,Bombay

ChiefEngineer(SewerageProjects)(Alternate)

Copyright1984
BUREAUOFINDIANSTANDARDS
ThispublicationisprotectedundertheIndianCopyrightAct(XIVof1957)andreproductioninwholeorinpart
byanymeansexceptwithwrittenpermissionofthepublishershallbedeemedtobeaninfringementofcopyrightunder
thesaidAct.
1

Members
ShriR.A.Khanna

Representing
PublicHealthEngineeringDepartment,GovernmentofMadhyaPradesh,Bhopal

ShriD.K.Mitra(AlternateI)
ShriI.S.Baweja(AlternateII)
ShriP.Krishanan

CentralPublicWorksDepartment,NewDelhi

SurveyorOpWorks1(NDZ)(Alternate)
ShriM.Y.Madan

TheHindustanConstructionCoLtd,Bombay

ShriC.E.S.Rao(Alternate)
ShriS.L.Maini

PublicWorksDepartment,PublicHealthBranch,GovernmentofPunjab,Patiala

ShriR.Natarajan

HindustanDorrOliverLtd,Bombay

ShriB.M.Rahul(Alternate)
ShriK.J.Nath

AllIndiaInstituteofHygieneandPublicHealth,Calcutta

ShriD.Gusin(Alternate)
ShriA.Poonabadam

TamilNaduWaterSupply&DrainageBoard,Madras

ProfV.Raman

NationalEnvironmentalEngineeringResearchInstitute(CSIR),Nagpur

ShriS.R.Kshirsagar(Alternate)
ShriRanjitSingh

MinistryofRailways

DrA.V.R.Rao

NationalBuildingsOrganization,NewDelhi

ShriO.P.Ratra(Alternate)
Secretary

IndianWaterWorksAssociation,Bombay

SecretaryGeneral

InstitutionofPublicHealthEngineersIndia,Calcutta

ShriR.N.Banerjee(Alternate)
ShriL.R.Sehgal

L.R.Sehgal&Co,NewDelhi

ShriS.K.Sharma

CentralBuildingResearchInstitute(CSIR),Roorkee

ShriB.N.Thyagaraja

BangaloreWaterSupplyandSewerageBoard,Bangalore

ShriH.S.Puttakempanna(Alternate)
https://law.resource.org/pub/in/bis/S03/is.5329.1983.html

2/25

11/4/2016

IndianStandard:CODEOFPRACTICEFORSANITARYPIPEWORKABOVEGROUNDFORBUILDINGS

ShriV.Varadarajan

MadrasMetropolitanWaterSupplyandSewerageBoard,Madras

ShriS.Daivamani(Altenate)
ShriG.Raman,

DirectorGeneral,ISI(ExofficioMember)

Director(CivEngg)

Secretary
ShriA.K.Avasthy
AssistantDirector(CivEngg),ISI
(continuedonpage26)
IndianStandard
CODEOFPRACTICEFORSANITARYPIPEWORKABOVEGROUNDFORBUILDINGS

(FirstRevision)

0.FOREWORD
0.1
ThisIndianStandard(FirstRevision)wasadoptedbytheIndianStandardsInstitutionon30
November1983,afterthedraftfinalizedbytheWaterSupplyandSanitationSectionalCommitteehadbeen
approvedbytheCivilEngineeringDivisionCouncil.

0.2
Allaspectsofdesign,layoutconstructionandmaintenanceofdrainsforcarriageofwastesandsewage
togetherwithallancilliaryworkslikemanholes,inspectionchambers,etc,havebeengenerallydealtwithin
IS:17421983*.However,acodeofpracticespeciallydealingwiththedesignandlayoutofsoilandwaste
pipesofbuildingswasfeltnecessarytogivedetailedguidanceforthispartofwork.
0.2.1
Thecodecoversthetraditionaltwopipesystemofplumbingandthemodernmethodsofplumbing,
namely,theonepipeandthesinglestacksystem.Inthisrevisionguidanceforthechoiceofplumbingsystem
andsafeguardsforsinglestacksystemhavebeencoveredindetail.Therequirementsforsoilpipe,wastepipe
andventilatingpipehavealsobeenincluded.

0.3
Thiscoderepresentsastandardofgoodpracticesand,therefore,takestheformofrecommendations.

0.4
Forthepurposeofdecidingwhetheraparticularrequirementofthisstandardiscompliedwith,the
finalvalue,observedorcalculated,expressingtheresultofatestoranalysis,shallberoundedoffin
accordancewithIS:21960.Thenumberofsignificantplacesretainedintheroundedoffvalueshouldbe
thesameasthatofthespecifiedvalueinthisstandard.
*Codeofpracticeforbuildingdrainage(firstrevision).
Rulesforroundingoffnumericalvalues(revised).
3

1.SCOPE

https://law.resource.org/pub/in/bis/S03/is.5329.1983.html

3/25

11/4/2016

IndianStandard:CODEOFPRACTICEFORSANITARYPIPEWORKABOVEGROUNDFORBUILDINGS

1.1
Thiscodedealswiththedesign,installationofsoil,wasteandventilatingpipeswheretheyoccurabove
groundbothinsideandoutsidethebuilding.

1.2
Rainwaterpipesarenotcoveredbythiscode.

2.TERMINOLOGY
2.0
Forthepurposeofthisstandard,thefollowingdefinitionsshallapply.

2.1
BackPressureAirorwastewaterfrompipesbeingforcedupthroughtraps,

2.2
BranchVentilatingPipe(B.V.P.)Apipe,oneendofwhichisconnectedtothesystemadjacent
tothetrapofanapplianceandtheothertoamainventilatingpipeoradrainventilatingpipe.Itisfittedto
preventlossofwatersealfromatrapowingtopartialvacuumbackpressure,orsurgingcausedbyair
movementwithinthepipesystem.Italsoprovidesventilationforthebranchwastepipe.

2.3
BranchSoilPipe(B.S.P.)Apipeconnectingoneormoresoilappliancestothemainsoilpipe.

2.4
BranchWastePipe(B.W.P)Apipeconnectingoneormorewasteappliancestothemainwaste
pipe.

2.5
BranchSoilWastePipe(B.S.W.P.)Apipeconnectingoneormoresoiland/orwaste
appliancestothemainsoilwastepipe(onepipesystem).

2.6
BuildingDrain(seeFig.1)Thebuilding(house)drainisthepartofthelowesthorizontalpiping
ofadrainagesystemwhichreceivesthedischargefromsoil,waste,andotherdrainagepipesinsidethewalls
ofthebuildingandconveysittothebuilding(house)sewerbeginningonemetreoutsidethebuildingwall.

2.7
BuildingSewer(seeFig.1)Thebuilding(house)seweristhepartofthehorizontalpipingofa
drainagesystemwhichextendfromtheendofthebuildingdrainandwhichreceivesthedischargeofthe
buildingdrainandconveysittoapublicsewer,privatesewer,individualsewagedisposalsystem,orother
pointofdisposal.
https://law.resource.org/pub/in/bis/S03/is.5329.1983.html

4/25

11/4/2016

IndianStandard:CODEOFPRACTICEFORSANITARYPIPEWORKABOVEGROUNDFORBUILDINGS

2.8
CleaningEyeAnaccessopeninginapipeorpipefittingarrangedtofacilitatetheclearingof
obstructionsandfittedwithremoveablecover.

2.9
CrownofTrapThetopmostpointoftheinsideofatrapoutlet.

2.10
DiameterThenominaldiameterofpipesfittings.
4

Fig.1DefinitionofBuildingDrainandBuildingSewer

2.11
DrainAnypipewhichconveysdischargesfromsanitaryappliancesinadrainagesystem.

2.12
DrainVentilatingPipe(D.V.P.)Apipeinstalledtoprovideflowofairtoorfromadrainto
preventundueconcentrationoffoulairindrain.Mainsoilpipeormainwastepipemayserveasdrain
ventilatingpipewherevertheirupperportions,whichdonotreceivedischarges,areextendedtotherooflevel
andletopentoair.

2.13
HolderbatAbracketmadeinhalves,withboltsandnutsforjoiningthehalvesandwithprovision
forbuildinginorscrewingtothestructure.

2.14
InducedSiphonageTheextractionofwaterfromatrapbysiphonagesetupbyreductionof
pressureattheoutletofthetrap.

2.15
https://law.resource.org/pub/in/bis/S03/is.5329.1983.html

5/25

11/4/2016

IndianStandard:CODEOFPRACTICEFORSANITARYPIPEWORKABOVEGROUNDFORBUILDINGS

MainSoilPipe(M.S.P.)Apipeconnectingoneormorebranchwastepipestothedrain.

2.16
MainVentilatingPipe(M.V.P.)Apipewhichreceivesanumberofbranchventilatingpipes.

2.17
MainWastePipe(M.W.P.)Apipeconnectingoneormorebranchwastepipestothedrain.
5

2.18
MainSoilWastePipe(M.S.W.P.)Apipeconnectingonemorebranchsoilwastepipestothe
drain.

2.19
PipeEarsTwowingscastintegrallywiththepipesocketprovidedwithholestotakefixingnailsor
screws.

2.20
PipeSystemsThesystemtobeadoptedwilldependonthetypeandplanningofthebuildingin
whichitistobeinstalledandwillbeoneofthefollowing:
a.TwoPipeSystem(seeFig.2)Adischargepipesystemcomprisingtwoindependentdischargepipes
oneofwhichconveyssoildirectlytothedrain,theotherconveyingwastewatertothedrainthrougha
trappedgully.Thesystemmayalsorequireventilatingpipes.
b.OnePipeSystem(seeFig.3)Theplumbingsysteminwhichthewasteconnectionfromsinks,baths
andwashbasinsandthesoilpipebranchesareallcollectedintoonemainpipewhichisconnected
directlytothedrainagesystem.Gullytrapsandwastepipesarecompletelydispensedwithbutallthe
trapsofwaterclosets,basin,etc,arecompletelyventilatedtopreservewaterseal.
c.SingleStackSystem(seeFig.4Aand4B)Onepipesystemwithouttrapventilationpipework.

2.21
SelfSiphonageTheextractionofwaterfromatrapbysiphonagesetupbythemomentumofthe
dischargefromthesanitaryappliancetowhichthetrapisattached.

2.22
StackAmainverticaldischargeorventilatingpipe.

2.23
TrapAfittingordevicesodesignedandconstructedastoprovide,whenproperlyvented,aliquid
sealwhichwillpreventthebackpassageofairwithoutmateriallyaffectingtheflowofsewageorwater
through.

2.24
WaterSealThewaterinatrapwhichactsasabarriertothepassageofairthroughthetrap.
https://law.resource.org/pub/in/bis/S03/is.5329.1983.html

6/25

11/4/2016

IndianStandard:CODEOFPRACTICEFORSANITARYPIPEWORKABOVEGROUNDFORBUILDINGS

2.25
FixtureUnitAquantityintermsofwhichtheloadproducingeffectsontheplumbingsystemof
differentkindofplumbingfixturesareexpressedonsomearbitrarilychosenscale.

3.PRELIMINARYDATAFORDESIGN
3.1
Inordertodesignasoilandwastepipessystemaboveground,informationonthefollowingitems
shouldbecollected:

a.NewWorkIntheinitialstages,thereshouldbeconsultationbetweenthelocalauthority,owner,
architectandengineerconcerningthefollowingmatters:
1.Number,positionandtypesofappliancestobeinstalled
2.Positionandsizeofsewersandanyprecautionsnecessarytoensuresatisfactoryworkingofthe
drainagesystemandtoavoidfloodingofthepremisesand
3.Requirementsoflocalauthority.
b.ExistingWorkAnyreportonexistingworkshouldincludethefollowing:
1.Resultsoftests,
2.Detailsofappliancesconnectedtothedrainagesystem,
3.Descriptionoftheconditionofthepipeworkandfittings,and
4.Particularsoftheventilationofthedrainagesystem.
c.InformationRequiredbyLocalAuthorities
1.Notificationontheappropriateformsandparticularsofthepropossdwork,and
2.Drawings.
d.InformationRequiredbythePlumbingContractor
1.DrawingsThearchitectorengineershouldadvisetheplumbingcontractoroftheacceptance
oftheproposalbythelocalauthorityandprovideanexactcopyoftheapproveddrawings.These
drawingsshouldshowanyspecialannotationsmadebythelocalauthority,alsonotesastoany
preparatoryconstructionalworkwhichmayberequiredtoaccommodatethepipework.The
plumbingcontractorshouldbeprovidedwithsufficientcopiesofthelargescaleworking
drawingsoftheinstallationcontainingnotesofanyspecialrequirementsandgivingallnecessary
dimensions.
2.SpecificationTheplumbingcontractorwillrequirecopiesoftherelevantclausesofthemain
specificationwhichshouldincludethefollowing:
1.Generaldescriptionofthework,
2.Informationastostatutoryauthoritiesrequirements,ifany,
3.Descriptionofmaterialsrequired,
4.Methodsoffixingandjointing,and
5.Anyspecialrequirements.

3.2

https://law.resource.org/pub/in/bis/S03/is.5329.1983.html

7/25

11/4/2016

IndianStandard:CODEOFPRACTICEFORSANITARYPIPEWORKABOVEGROUNDFORBUILDINGS

Theworkshallbecarriedoutbyaplumberdulylicensedbylocalauthoritiesinconformitywiththe
ruleslaiddownforthepurpose.

4.TIMESCHEDULE
4.1
Atimeschedulefortheinstallationofthesoilandwastepipeworkshouldbepreparedandco
ordinatedwiththeprogrammeofthemainbuildingwork,particularlywiththatpartofitdealingwiththe
undergrounddrainagesystem.Thisschedulemayrequireadjustmentfromtimetotimetoaccordwiththe
progressofthejob.Thefollowingareimportantpointstobeconsideredinthepreparationofatime
schedule:
a.Dateswhendrawingsarerequired,
b.Datesforthesupplyanddeliveryofmaterials,and
c.Datesforthestartandcompletionofindividualsectionofthework.

5.MATERIAL
5.1
Materialsandcomponentsofthematerialsusedintheconstructionworkdescribedinthecodeshall
conformtotherequirementslaiddownintherelevantIndianStandards.However,wherenoIndian
Standardexistsontheparticularitem,materialsusedshallbeofsatisfactoryqualityandworkmanship
acceptabletotheowner.

5.2
ChoiceofMaterialsforPipesandFittingsThefollowingmaterialmaybeusedforasanitary
pipeworksystem:
a.Asbestoscement[conformingtoIS:1626(Part1)1980*]
b.Castiron(conformingtoIS:15361976),IS:15371976,IS:15381976,IS:17291979,andIS:
39891970)
c.Saltglazedstonewarepipes(conformingtoIS:65119802**)
d.Galvanizedsteelandwroughtiron[conformingtoIS:1239(Part1)1979]and
e.Anyothermaterialasapprovedbythelocalauthority.
*Specificationforasbestoscementbuildingpipesandpipefittings,guttersandgutterfittingsand
roofingfittings:Part1Pipeandpipefittings(firstrevision).
Specificationforcentrifugallycast(spun)ironpressurepipesforwater,gasandsewage(second
revision).
Specificationforverticallycastironpressurepipesforwater,gasandsewage(firstrevision).
Specificationforcastironfittingsforpressurepipesforwater,gasandsewage(secondrevision).
(Specificationforsandcastironspigotandsocketsoil,wasteandventilatingpipes,fittingsand
accessories(firstrevision).
Specificationforcentrifugallycast(spun)ironspigotandsocketsoil,wasteandventilatingpipes,
fittingsandaccessories(firstrevision).
**Specificationforsaltglazedstonewarepipesandfittings(fourthrevision).
https://law.resource.org/pub/in/bis/S03/is.5329.1983.html

8/25

11/4/2016

IndianStandard:CODEOFPRACTICEFORSANITARYPIPEWORKABOVEGROUNDFORBUILDINGS

Specificationformildsteeltubes(fourthrevision).
8

5.2.1
Careshouldbetakentoselectmaterialsresistanttocorrosioncausedbytheliquidcarried,by
atmosphericconditions,orbyelectrolysis.

6.DESIGNCONSIDERATIONS
6.1
PipeSystemsThedesigntobeadoptedwilldependonthetypeandplanningofthebuildingsto
whichitistobeinstalledandwillbeoneofthefollowing:
a.Thetwopipesystem(seeFig.2),
b.Theonepipesystem(seeFig.3),or
c.Thesinglestacksystem(seeFig.4Aand4B)
6.1.1
ChoiceofPlumbingSystemWherethesullagefrombathsandkitchenscanbedealtwithseparately
foruseingardeningoranyothersuchpurposes,thetwopipesystemisadvantageous.Obviously,theone
pipesystemismoreeconomicalandhasapplicationwherealltypesofwastewatersaretakeninacommon
sewerlinetotheplaceofdisposalortreatment.Boththesesystemsarefullyventilatedbyasystemof
ventilatingpipe.However,thesedaysthesinglestacksystemwithoutanyventpipesystem,wherethestack
itselfismadetoservetheventrequirementsalsobyrestrictingtheflowinthestack,isbeingused.This
systemisrecommendedwith100mmdiameterstackforupto5storeybuildings.Notmorethantwotoilet
unitscandischargetothesinglestackateachfloorlevel.Foranydifferentcase,thepermissionofthelocal
authorityshallbeobtained.Inhighrisebuildings,apartiallyventilatedonepipesystemisbeingusedwhere
theventstackisconnectedtothedrainagestackortheWCsateachoralternatefloors.Thesafeguardsfor
thesinglestacksystemarestipulatedin6.9.2.Thefullyventilatedsystemdoesnotdemandanyspecial
safeguards.

6.2
PipeCapacitiesPipediametershouldbecalculatedaccordingto4.5.1ofIS:17421983*.
6.2.1
BranchesandstackswhichreceivedischargesfromWCpansshouldnotbelessthan100mm,except
wheretheoutletfromthesiphonicwaterclosetis80mminwhichcaseabranchpipeof80mmmaybe
usedforoutletoffloortraps75mmdiameterpipesmaybeused.
6.2.2
Thegradientofahorizontalbranchshouldnotbeflatterthan1in50andnotsteeperthan1in10.

6.3
LayoutofPipesPipeworkandappliancesshouldbesoarrangedastoallowclosegroupingof
connectionspreferablywithawaterclosetneartothemainsoilpipe.Thelevelofthetrapoutletofan
https://law.resource.org/pub/in/bis/S03/is.5329.1983.html

9/25

11/4/2016

IndianStandard:CODEOFPRACTICEFORSANITARYPIPEWORKABOVEGROUNDFORBUILDINGS

applianceshallbestudiedinrelationtothelevelofthefloorandthebranchpipe.
*Codeofpracticeforbuildingdrainage(firstrevision)
9

Fig.2DiagramofTwoPipeSystem
10

https://law.resource.org/pub/in/bis/S03/is.5329.1983.html

10/25

11/4/2016

IndianStandard:CODEOFPRACTICEFORSANITARYPIPEWORKABOVEGROUNDFORBUILDINGS

Fig.3DiagramofOnePipeSystem
11

https://law.resource.org/pub/in/bis/S03/is.5329.1983.html

11/25

11/4/2016

IndianStandard:CODEOFPRACTICEFORSANITARYPIPEWORKABOVEGROUNDFORBUILDINGS

Fig.4MainFeaturesofDesignofSingleStackSystem
6.3.1
Pipesshouldbeplaced,fixedandjointedsoastoavoidriskofdamagethroughvariationsin
temperature.Unlesssuitableprecautionsaretaken,thejointingofpipesexposedtoundulyhightemperatures
maybecomeunsatisfactory.Smallwastepipesareparticularlyliabletodamagecausedbythefreezingof
waterfromaleakingtapinplaceswherefreezingnormallyoccours.
6.3.2
Thepipeworkinbranchconnectionsshouldalwaysbearrangedtoallowfreedrainageofthesystem.
Connectionstomainorbranchpipesshouldbesoarrangedastopreventcrossflowfromoneapplianceto
another.Connectionsshouldbemadewithaneasysweepinthedirectionofflowparticularlyinconnection
inthesinglestacksystem(seeFig.4).
12

6.3.2.1

https://law.resource.org/pub/in/bis/S03/is.5329.1983.html

12/25

11/4/2016

IndianStandard:CODEOFPRACTICEFORSANITARYPIPEWORKABOVEGROUNDFORBUILDINGS

Whenthepipesareconcealed,inaccessibleorlaidexposedalongwiththeinternalfaceofthewalls,
theyshouldpreferablybeofcastiron.Inthegroundfloorallthepipes,includingthoselaidontheexternal
faceofthewalls,shouldbeofcastiron.
6.3.2.2

Alljointsinpipeworkandofpipeworktoapplianceshouldbemadeinsuchamannerastobeairtight
andwatertightandtoremainsoduringuse.Careshouldbetakentoensurethatnojointingmaterialprojects
insidetheboreofthepipe.Someflexibilityisdesirablywherethereispossibilityofmovementbetweenthe
pipesorbetweenthepipesandtheappliances.
6.3.2.3

Thejointshallbemadeofneatcementpastewellcaulkedlikelead(withwatercontentnotexceeding
30percent)preferablywithasbestosorhempfibrecementjointsshouldbeavoidedwherethejointsare
likelytobeexposedtodirectsunlightorheat.Whererubberringsareusedforthejointingofexternalpipes,
theannularspaceinthesocketaboveringshouldbefilledwithasuitablemasticcompound.
6.3.3
Bendsshouldbeoflongradiuswherepracticable.Inthecaseofbendsinthebottommostpipesthey
shouldnecessarilybeoflongradiusandshouldpreferablybemadeof135(1/8)bends.
6.3.4
Ampleprovisionshouldbemadeforaccesstoallpipeworkandtheembeddingofjointsinwallsshould
beavoidedasfaraspossible.
6.3.5
Allpipeworkadjacenttolivingorsleepingquartersshouldbeinsulatedagainstsoundtransmissionand
stepsshouldbetakentoavoidthetransmissionofnoisefromoneapartmenttoanotherbywayofthepipe
system(seeIS:19501962*).

6.4
ConnectionofFixturesFixturesmaypreferablybeconnectedtothestackdirectlyorthrough
floortraps.

6.5Traps
6.5.1
GeneralTheentryoffoulairtothebuildingshouldbepreventedbysuitabletraps,properlysited.
6.5.2
Trapsshouldalwaysbeofaselfcleansingpattern.Atrapwhichisnotanintegralpartofanappliance
shouldbedirectlyattachedtoitsoutlet,andthepipeboreshouldbeuniformthroughoutandhaveasmooth
surface.
https://law.resource.org/pub/in/bis/S03/is.5329.1983.html

13/25

11/4/2016

IndianStandard:CODEOFPRACTICEFORSANITARYPIPEWORKABOVEGROUNDFORBUILDINGS

6.5.3
Trapsforuseindomesticwasteinstallationsandallothertrapsshouldbeconvenientlyaccessbileand
providedwithcleaningeyes,orothermeansofcleaning.
*Codeofpracticeforsoundinsulationofnonindustrialbuildings
13

6.5.4
SelectionofTrapsforVariousPurposesThefactorsgiveninTables1and2shouldreceive
considerationinrelationtoattachedtraps.
TABLE1MINIMUMINTERNALDIAMETERSFORWASTEAPPLIANCES
ITEM

DIAMETER

mm

Drinkingfountains

25

Washbasins

30

Bidets

30

Domesticsinksandbaths

40

Showerbathtrays

40

Domesticbathtubs

50

Hotelandcanteensinks

50

Urinals:

50

Stallurinals(withnotmorethan120mofchanneldrainage)
Lipurinals

40

Floortraps(outletdiameter)

65

TABLE2DEPTHOFSEALSFORDIFFERENTPLUMBINGSYSTEM
(Clause6.5.4)
SLNO

ITEM

TWOPIPE
mm

ONEPIPE
mm

SINGLESTACK
mm

50

50

50

50

50

50

a)Whereattachedtobranchwastepipesofdia75mmormore

40

40

40

b)Where,attachedtobranchwastepipeoflessthan75mmdia

40

40

75

i) Waterclosets
ii) Floortraps
iii) Otherfixtures,directlyconnectedtothestack:

NoteWhenconnectionismadethroughfloortrap,noseparatesealsarerequiredforindividualfixtures.

6.6SoilPipe
6.6.1
Asoilpipeconveyingtoadrainanysolidorliquidfilthshallbecircularandshallhaveaminimum
diameterof100mm.
14

6.6.2

https://law.resource.org/pub/in/bis/S03/is.5329.1983.html

14/25

11/4/2016

IndianStandard:CODEOFPRACTICEFORSANITARYPIPEWORKABOVEGROUNDFORBUILDINGS

Exceptwhereitisimpracticable,thesoilpipeshallbesituatedoutsidethebuildingorinsuitably
designedpipeshaftsandshallbecontinuedupwardswithoutdiminutionofitsdiameter,and(exceptwhereit
isunavoidable)withoutanybendorangle,tosuchaheightandpositionastoaffordbymeansofitsopenend
asafeoutletforfoulair.Thepositionoftheopenendwithitscoveringshallbesuchastocomplywith6.8
relatingtoventilatingpipe.Evenifthepipesarelaidinexternalchases,thesoilpipesshallnotbepermitted
onawallabuttingastreetunlesstheAuthorityissatisfiedthatitisunavoidable.Wherepipeshaftsare
providedthecrosssectionalareashallbesuchastoallowfreeandunhamperedaccesstothepipestobe
installedintheshaftandinnocaseshallthecrosssectionbelessthanasquareof1metreside.Allpipe
shaftsshallbeprovidedwithanaccessdooratgroundlevelandfacilitiesforventilation.
6.6.3
Soilpipes,whetherinsideoroutsidethebuilding,shallnotbeconnectedwithanyrainwaterpipeand
thereshallnotbeanytrapinsuchsoilpipeorbetweenitanydrainwithwhichitisconnected.
6.6.4
Soilpipesshallpreferablybeofcastiron.Asbestoscementbuildingpipesmayalsobeusedassoilpipes
onlyabovegroundlevel.
6.6.5
Thesoilpipeshallbeprovidedwithheelrestbendwhichshallrestonsoundfooting.Itshallbefixed
atleast50mmclearofthefinishedsurfaceofthewallbymeansofsuitableclampsofapprovedtype.

6.7WastePipe
6.7.1
Everypipeinabuildingforearringoffthewasteoroverflowwaterfromeverybath,washbasinorsink
toadrainshallbeof32to50mmdiameter,andshallbetrappedimmediatelybeneathsuchwashbasinor
sinkbyanefficientsiphontrapwithadequatemeansforinpectionandcleaning.Suchtrapsshallbe
ventilatedintotheexternalairwheneversuchventilationisnecessarytopreservethesealofthetrap.Waste
pipes,traps,etc,shallbeconstructedofiron,head,brass,stoneware,asbestoscementorotherapproved
material.Theoverflowpipefromwashbasins,sinks,etc,shallbeconnectedwiththewastepipeimmediately
abovethetrap.Verticalpipescarryingoffwastewatershallhaveaminimumdiameterof75mm.
NoteWhereverwashbasinsandsinkshaveinbuiltoverflowarrangements,thereisno
needtoprovideoverflowpipesinsuchcases.
6.7.2
Everypipeinabuildingforcarryingoffwastewatertoadrainshallbetakenthroughanexternalwall
ofthebuildingbytheshortestpracticableline,andshalldischargebelowthegratingorsurfaceboxofthe
chamberbutabovethegratingofaproperlytrappedgully.Thewastepipeshallbecontinuedupwards
withoutanydiminutioninitsdiameterand(exceptwhenunavoidable)withoutanybendorangleto
15

suchaheightandpositionastoaffordbymeansoftheopenendofthewastepipe,asafeoutletfor
foulair,thepositionoftheopenendanditscoveringbeingsuchastocomplywiththecondition.
6.7.3

https://law.resource.org/pub/in/bis/S03/is.5329.1983.html

15/25

11/4/2016

IndianStandard:CODEOFPRACTICEFORSANITARYPIPEWORKABOVEGROUNDFORBUILDINGS

Exceptwhereitisimpracticable,thecommonwastepipeshallbesituatedoutsidethebuildingand
shallbecontinuedupwardswithoutdiminutionofitsdiameter(exceptwhereitisunavoidable)withoutany
bendoranglebeingformedtosuchaheightandpositionastoaffordbymeansoftheopenendasafeoutlet
forfoulair,thepositionoftheopenendandthecoveringthereafterbeingsuchastocomplywiththe
conditionssetoutinventilatedpipe.
6.7.4
Thewastepipeshallbefinallyattachedtothewallatleast5cmclearofit,ifthewastepipeisofcast
iron,thepipeshallbesecuredtothewallsproperlyfixedholderbatsorequallysuitableandefficientmeans.

6.8VentilatingPipe
6.8.1
Ventilatingpipesshouldbesoinstalledthatwatercannotberetainedinthem.Theyshouldbefixed
vertically.Wheneverpossiblehorizontalrunsshouldbeavoided.Ventilatingpipeshallbecarriedtosucha
heightandinsuchapositionastoaffordbymeansoftheopenendofsuchpipeorventshaft,asafeoutlet
forfoulairwiththeleastpossiblenuisance.
6.8.2
Theupperendofthemainventilatingpipemaybecontinuedtotheopenairaboverooflevelas
separatepipe,oritmayjointtheMSPand/orMWPabovethefloorlevelofthehighestappliance.Itslower
endmaybecarrieddowntojointhedrainatapointwhereairreliefmayalwaysbemaintained.Fourtypical
methodsofjointingthemainventilatingpipeatthelowerendaregiveninFig.5.
6.8.3
BranchventilatingpipesshouldbeconnectedtothetopoftheBSPandBWPbetween75mmand450
mmfromthecrownofthetrap.
6.8.4
Theventilatingpipeshallalwaysbetakentoapoint150cmabovetheleveloftheeavesorflatroofor
terraceparapetwhicheverishigherorthetopofanywindowwithinahorizontaldistanceof3m.Theleast
dimensionshallbetakenasaminimumandlocalconditionsshallbetakenintoaccount.Theupperendof
everyventilatingpipeshallbeprotectedbymeansofacowl.
6.8.5
Incasetheadjoiningbuildingistaller,theventilatingpipeshallbecarriedhigherthantheroofofthe
adjacentbuilding,whereveritispossible.
16

https://law.resource.org/pub/in/bis/S03/is.5329.1983.html

16/25

11/4/2016

IndianStandard:CODEOFPRACTICEFORSANITARYPIPEWORKABOVEGROUNDFORBUILDINGS

Fig.5EndConnectionsofVentPipe
17

6.8.6Sizes

https://law.resource.org/pub/in/bis/S03/is.5329.1983.html

17/25

11/4/2016

IndianStandard:CODEOFPRACTICEFORSANITARYPIPEWORKABOVEGROUNDFORBUILDINGS

6.8.6.1

Thebuildingdrainventilatingpipeshallbeofnotlessthan75mmdiameter.When,however,itisused
asMSPorMWP,theupperportion,whichdoesnotcarrydischarges,shallnotbeoflesserdiameterthanthe
remainingportion.
6.8.6.2

Thediameterofthemainventilatingpipeshallnotbelessthan50mm.
6.8.6.3

Abranchventilatingpipeonawastepipeinbothoneandtwopipesystemsshallbeofnotlessthan
twothirdsthediameterofthebranchwasteventilatedsubjecttoaminimumof25mm.
6.8.6.4

Abranchventilatingpipeonasoilpipeinbothoneandtwopipesystemsshallbenotlessthan32
mmindiameter.

6.9DesignDataforSingleStackPlumbing
6.9.1
ThefollowingrecommendationsareconditionaluponthosegiveninTable3:
a.Theapplianceshouldbegroupedascloselyaspossibleroundthemainstacksoastokeepthebranch
pipesshortandreducenoise.
b.Branchconnectionsshouldbeoflargeradiusalongtheinvert(seeFig.6).
c.Flatgradientsreduceselfsiphonageandnoisewastepipesshouldfallatbetween1:50and1:10.
d.AtypicalmethodofsinglestacksystemofplumbingisshowninFig.4Aand4B.
6.9.2SafeguardsforSingleStackSystem
a.Asfaraspracticable,thefixturesonfloorsshallbeconnectedtostackinorderofincreasingdischarge
rateinthedownwarddirection.
b.Theverticaldistancebetweenthewastebranch(fromfloortraporfromtheindividualappliance)and
thesoilbranchconnection,whensoilpipeisconnectedtostackabovethewastepipe,shallbenotless
than200mm.
18

https://law.resource.org/pub/in/bis/S03/is.5329.1983.html

18/25

11/4/2016

IndianStandard:CODEOFPRACTICEFORSANITARYPIPEWORKABOVEGROUNDFORBUILDINGS

Fig.6SingleStackSystemWastePipeConnections
c.Depthofwatersealtrapsfordifferentfixturesshallbeasbelow:
Waterclosets

50mm

Floortraps

50mm

Otherfixturesdirectlyconnectedtothestack:

19

1)

Whereattachedtobranchwastepipesofdia75mmormore

40mm

2)

Whereattachedtobranchwastepipesoflessthan75mmdia

75mm

NoteWhenconnectionismadethroughfloortrapnoseparatesealsarerequiredforindividual
fixtures.
d.BranchesandstackswhichreceivedischargesfromW.C.pansshouldnotbelessthan100mm,except
wheretheoutletfromthesiphonicwaterclosetis80mminwhichcaseabranchpipeof80mmmay
beusedforoutletoffloortraps75mmdiapipesmaybeused.
e.Thehorizontalbranchdistanceforfixturesfromstackbend(s)atthefootofstacktoavoidback
pressureaswellasverticaldistancebetweenthelowestconnectionandtheinvertofdrainshallbeas
showninFig.4A.
f.Fortallbuildings,groundfloorappliancesarerecommendedtobeconnecteddirectlyto
manhole/inspectionchamber.
6.9.2.1

AdditionalrequirementsThepipesshallbelaidinstraightlinesasfaraspossibleinbothverticaland
horizontalplans.Anythingthatislikelytocauseirregularityofflow,suchasabruptchangesofdirection,
shallbeavoided.Nobendsandjunctionswhatsoevershallbepermittedinthesewersexceptatmanholesand
inspectionchambers.
https://law.resource.org/pub/in/bis/S03/is.5329.1983.html

19/25

11/4/2016

IndianStandard:CODEOFPRACTICEFORSANITARYPIPEWORKABOVEGROUNDFORBUILDINGS

6.9.3
StackSizeThesizeshallbe100mmdiameter.
6.9.4
SingleBranchesandFittingsTable3givesrecommendationsforthedesignofsinglestacksystem.
Allappliancesdirectlyconnectedtostacksaretrapped.
6.9.4.1

Pipesshouldfallgraduallyandcontinuouslyinthedirectionofflow.
6.9.5
CombinedBathandBasinWasteWhenthebasinandbathareatsomedistancefromthestack,it
maybecheaperandsimplertocombinethewastepipesintoonethantoruneachseparatelytothestack.
Alternatively,a32mmdiatrapwithashort32mmtailpipemaybearrangedtodischargeinto38mmor50
mmwastepipe.Anybendsinthewasteshouldbeoflargeradius.

7.INSPECTIONANDTESTING
7.1
InspectionWorkshouldbeinspectedduringinstallationandtestsappliedoncompletion,care
beingtakenthatallworkwhichistobeencasedorconcealedistestedbeforeitisfinallyenclosed.
7.1.1
Pipesystemsshouldbetestedforgastightness,andforhydraulicperformance(see7.2).Inspection
shouldbecarriedouttoensurethefollowing:
a.Workaccordswiththedrawingsandspecification
b.Allpipebrackets,clips,etc,aresecurelyfixed
20

c.Fixingarecorrectlyspaced
d.Pipeisprotectedwherenecessarybythermalinsulation
e.Embeddedpipeworkisproperlyprotectedbeforesealingin
f.Allaccesscovers,capsorplugs:
1.areaccessible,
2.aresomadethattheinternalfacestrulycompletetheinternalbore,
3.causenoobstructioninthepipebore,and
4.arewelljointed.
TABLE3RECOMMENDATIONSFORDESIGNOFSINGLESTACKSYSTEM
(Clause6.9.4)
SL COMPONENT
NO.

ACTIONTO
BE
GUARDED
AGAINST

https://law.resource.org/pub/in/bis/S03/is.5329.1983.html

DESIGNRECOMMENDATIONS

20/25

11/4/2016

IndianStandard:CODEOFPRACTICEFORSANITARYPIPEWORKABOVEGROUNDFORBUILDINGS

(1)

(2)

i) Washbasin
waste

SL COMPONENT
NO.

(3)

(4)

Self

75mmsealPtraptobeused.Themaximumslopeofa40mmwastepipetobe

siphonage

determinedfromFig.7accordingtothelengthofthewastepipe.Anybendstobe

ACTIONTO
BE
GUARDED
AGAINST

DESIGNRECOMMENDATIONS

notlessthan75mmradiustocentreline.Wastepipeslongerthanthe
recommendedmaximumlengthof165cmshouldbevented,oralargerdiameter
wastepipeorapprovedresealingtrapshouldbeused

(1)
(2)
ii) Bathand

sinkwastes

Self (3)

(4)
75mmsealtrapstobeused.Selfsiphonagenotimportant.Lengthandslopeof

siphonage

wastebranchnotcritical,butlongwastepipesmaybetroubledbysedimentation

38mmtrap

andaccessforcleaningshouldbeprovided

and38mm
wastepipe

21

Backingupof PositionofentryofbathwasteintostacktobeasinFig.8,thebathwastepipesmay
discharge

beconnectedtothestacksothatitscentrelinemeetsthecentrelineofthestackator

fromW.C.

abovethepointwherethecentrelineoftheWCbranchmeetthecentrelineofthe

branchinto

stack,oratleast20cmbelowit

bathbranch
iii) Soilbranch

Induced

connectionto siphonage
stack

W.C.connectionsshouldbesweptinthedirectionofflow.Fittingsshouldhavea
minimumsweepofatleast5cmradius

lowerinthe
stackwhen
W.C.is
discharged

iv) Bendatfoot

Backpressure Bendtobeoflargeradiusortwo135bendstobeused.Verticaldistancebetween

ofstack(see

atlowest

lowestbranchconnectionandinvertofdraintobeatleast750mm(450mmfor2

Fig.4Aand

branch.

storeyedhouseswith100mmstack)

4B)

Buildupof
detergent
foam

v) Offsetsin
stacks

Backpressure Thereshouldbenooffsetsinstacksbelowthetopmostappliancesunlessventingis
aboveoffset

providedtorelieveanybackpressure.Offsetsabovethetopmostappliancesareofno
significance.

vi) Floortraps
and75mm

Induced

50mmsealtraptotheused.Slopsofthebranchpipemayvaryfrom1in50to1in

siphonage

10

branchpipe
NoteTherecommendationsapplytosystemswithsweptinletWCbranches.Withstraightinletbranchesa100mm
stackwithnoventshasbeenfoundsatisfactoryforuptofourstoreys,a150mmstackwithnoventshasbeenfound
satisfactoryforupto15storeys.

7.2TestingofSystem
7.2.1
WaterTestThewatertestmaybeappliedbeforetheappliancesareconnectedandmaybecarriedout
insectionssoastolimitthestaticheadto4.5m.Itisnecessarytosealallopeningsaffectedbythetestand
providesupporttotheplugsusedasstoppers.
7.2.2
AirTestTheairtestmaybeappliedbyinsertingexpandingrubbertestingplugsinthelowerand
upperendsofthemainsoilpipeandmainventilatingpipeandsealingtheplugswithwater,wherepossible.
https://law.resource.org/pub/in/bis/S03/is.5329.1983.html

21/25

11/4/2016

IndianStandard:CODEOFPRACTICEFORSANITARYPIPEWORKABOVEGROUNDFORBUILDINGS

22

Fig.7LengthandFallofBasinWasteDesignCurvefor32mmWasteand75mmSealPTraps
ConnectedtoSingleWashBasin
23

Fig.8ConnectionofBathWastetoStack
7.2.2.1

https://law.resource.org/pub/in/bis/S03/is.5329.1983.html

22/25

11/4/2016

IndianStandard:CODEOFPRACTICEFORSANITARYPIPEWORKABOVEGROUNDFORBUILDINGS

Thetestingplugattheupperendoftheventilatingpipeshouldbefittedwithateepiecewithacock
oneachbranch,onebranchbeingconnectedbyaflexibletubetoamanometer.Airpressureisthen
introducedintothesystemthroughtheotherbranchoftheteepieceuntilthedesiredpressureisshownon
themanometerscale.Thepressureappliedshouldbeequalto65mmwatergaugeandshouldremain
constantforaperiodofthreeminutestoprovethesoundnessoftheinstallation.
7.2.2.2

Alternatively,theairpressuremaybeappliedbypassingaflexibletubefromateepieceattachedtoa
manometerthroughthewatersealofthetrapofthesanitaryappliance,thetestthenbeingcarriedoutas
describedin7.2.2.1.
7.2.3
SmokeTestFaultsindicatedbytheairtestmaybelocatedbypumpingsmokeintothesystemwitha
smokemachine.Careshouldbetakentoensurethatthesystemisfilledwithsmokebeforesealingwith
plugs.
7.2.4
HydraulicPerformanceDischargetest,shouldbemadefromalltheappliances,singlyand
collectively.Obstructioninanyofthepipelinesshouldbetracedandthewholesystemexaminedforproper
hydraulicperformance,includingtheretentionofanadequatewatersealineachtrap.
24

7.2.4.1

Anydefectsrevealedbythetestsshouldbemadegood,andthetestsrepeateduntilasatisfactoryresult
isobtained.

7.3TestingtheEfficiencyoftheDesign
7.3.1
Asoiland/orwastepipesystemshould,undertests,withstandanyconditionofdischargeofits
applianceswhichmayoccurinpractice,withoutthedischargefromoneappliancebeingforcedupinto
another,andeverytrapshouldretainatleast25mmofitssealundertheseconditions.Thetestsshouldbe
designedtomakefullallowanceforthemaximumsuctionandpressureeffectswhichmayoccurasgiven
below:
a.Insmallinstallationswhenalltheappliancesaredischargingtogether,and
b.Inlargeinstallationswhensufficientappliancesaresimultaneouslydischargedtosimulatepeak
conditions.
7.3.2
Whentestingthesealsoftrapsfittedtoablutionaryappliances,thelattershouldbefilledtooverflow
levelandallowedtodischargeinthenormalway.
7.3.3

https://law.resource.org/pub/in/bis/S03/is.5329.1983.html

23/25

11/4/2016

IndianStandard:CODEOFPRACTICEFORSANITARYPIPEWORKABOVEGROUNDFORBUILDINGS

Testssimilartotheaboveshouldalsobecarriedoutbydischargingsomeappliances,whileothersare
emptywithplugsout.
7.3.4
Eachtestshouldbecarriedoutatleastthreetimesandthemaximumlossofsealinanyofthetests
shouldbetakenasthesignificantresult.
25

(Continuedfrompage2)
DrainageSubcommittee,BDC24:2
Convener

ShriP.G.Joshi
Members

Representing

MunicipalCorporationofGreaterBombay,Bombay

DeputyChiefEngineer(Sewerage)(AlternateShriP.G.Joshi)
AdditionalChiefEngineer(Water)

DelhiMunicipalCorporation,Delhi

DeputyDrainageEngineer(Alternate)
ChiefEngineer

PublicWorksDepartment,GovernmentofPunjab,Chandigarh

ChiefEngineer(General)

TamilNaduWaterSupplyandDrainageBoard,Madras

DeputyAdviser(PHE)

MinistryofWorksandHousing

ShriDevendraSingh

Inpersonalcapacity(16AMayaMahal,17thRoad,Khar,Bombay)

ShriK.GovindanNai

PublicHealthEngineeringDepartment,GovernmentofKerala,Trivandrum

ShriY.S.Murthy

NationalEnvironmentalEngineeringResearchInstitute(CSIR),Nagpur

ShriA.K.Seth(Alternate)
ShriS.K.Sharma

CentralBuildingResearchInstitute(CSIR),Roorkee

BUREAUOFINDIANSTANDARDS

26

Headquarters:
ManakBhavan,9BahadurShahZafarMarg,NEWDELHI110002
Talephones:3310131,3311375

Telegrams:
Manaksantha
(Commontoalloffices)

RegionalOffices:
Central:ManakBhavan,9BahadurShahZafarMarg,NEWDELHI110002

Telephones
3310131
3311375

*Eastern:1/14C.I.T.SchemeVIIM,V.I.P.Road,Maniktola,CALCUTTA700054

362499

Northern:SCO445446,Sector35C,

21843

CHANDIGARH160036

31641

Southern:C.I.T.Campus,MADRAS600113

412442
412519
412916

Western:Manakalaya,E9MIDC,Marol,Andheri(East),BOMBAY400093

6329295

BranchOffices:
PushpakNurmohamedShaikhMarg,Khanpur,AHMEDABAD380001

26348
26349

PeenyaindustrialArea,1stStage,BangaloreTumkurRoadBANGALORE560058
https://law.resource.org/pub/in/bis/S03/is.5329.1983.html

384955
24/25

11/4/2016

IndianStandard:CODEOFPRACTICEFORSANITARYPIPEWORKABOVEGROUNDFORBUILDINGS

384956
GangotriComplex,5thFloor,BhadbhadaRoad,T.T.Nagar,BHOPAL462003

66716

PlotNo.82/83,LewisRoad,BHUBANESHWAR751002

53627

53/5,WardNo.29,R.G.BaruaRoad,5thByelane,GUWAHATI781003

33177

5856CL.N.GuptaMarg(NampallyStationRoad),HYDERABAD500001
R14YudhisterMarg,CScheme,JAIPUR302005

231083
63471
69832

117/418BSarvodayaNagar,KANPUR208005

216876
218292

PatliputraIndustrialEstate,PATNA800013

62305

T.C.No.14/1421,UniversityP.O.,PalayamTRIVANDRUM695035

62104
62117

InspectionOffice(WithSalePoint):
Pushpanjali,1stFloor,205AWestHighCourtRoad,ShankarNagarSquare,NAGPUR

25171

440010
InstitutionofEngineers(India)Building,1332ShivajiNagar,PUNE411005
*SalesOfficeinCalcuttaisat5ChowringheeApproach,P.O.PrincepStreet,Calcutta

52435
276800

700072
SalesOfficeinBombayitatNoveltyChambers,GrantRoad,Bombay400007
SalesOfficeinBangaloreisatUnityBuilding,NarasimharajaSquareBangalore560002

896528
223871

27

https://law.resource.org/pub/in/bis/S03/is.5329.1983.html

25/25

Вам также может понравиться