Aeration Tank (ETP-TK-213)


Flow
BOD
MLSS
TSS
F/M ratio
Volume((Flow X BOD)/(MLSS X F/M))
SWD
Area
Length
Width
Free Board
HRT

175
250
4000
300
0.1
109.38
4.5
24.31
7.0
3.5
0.5
15

Oxygen Requirement calculation:


Flow:
Theoritical kg O2 required/kg of BOD:
Inlet BOD:
Hence BOD removed:
Total O2 required:
Oxygen required under Standard condition(SOR):

Hence
Calculation of Air required at field condition
SWD of Aeration Tank:
HLL of Aeration Tank at avg flow:
Height of diffuser:
Effective Aeration Depth:
SOTE:
Fraction of O2 in Air:
Specific gravity of Air:
Hence Air required(SOR/((SOTE X
Fraction
Air)X( Specific gravity of
Hours of of
operation:
Air):
Air required:
No of Working Air blower:
Capacity of Air Blower:
Capacity of Air Blower provided:
No of Blower Provided:
Hence no of operating Blower:
No of standby provided:

SOR =
Where
T:
Csw:
C'sw:
C:
:
:
F:
SOR:

4.5
4
0.2
3.8
24.8
23.18
1.29
1761.8
24
73.41
1
73.41
75
2
1
1

Free Air Delivery


No of diffusers required
No of diffusers provided
Calculation of SRT based on excess sludge :
Excees sludge generated/kg of BOD:
Kg of Total Sludge/day with total TSS
load:
Hence excess sludge:
Sludge solid consistency at bottom of
clarifier:
Volume of Excess sludge(Qw):
Hence sludge concentration(XR):
Volume Aeration tank:
MLSS concentration(X):

VIII

Secondary Clarifier Tank (ETP-TK-214)


Flow
Overflow Rate
Area
Diameter required
Diameter provided
SWD
Free Board
Total sludge=BOD Load + TSS Load
Solid Loading rate
Retention Time
Weir Loading
Feedwell Size

10
7.5
8

0.3
96.25
28.88
1
2.89
10000
109.38
4000

175
14
12.5
3.99
4
2.5
0.5
96.25
7.7
4.29
14
0.7

Sludge Recirculation Pump (ETP-PA-207A/S)


Flow
Capacity (based on 100% recirculation required during startup)

Head

175
7.3

10

m3/day
mg/lt
mg/lt (Accoring to sewage manual it may vary from 30005000)
mg/lt
(Accoring to sewage manual it may vary from0.10.18.)
m3
m
m2
m
m
m
hrs(As per Sewage manual HRT 1224 hr, Hence OK)

175 m3/day
1.5
250 mg/l
250 mg/l
65.63 kg/day(AOR)
AOR/[(( C'swC)/Csw) X 1.024^(T20) X XF)
Field Temperature
25
Solubility of Oxygen at 20degC
Solubility of O2 at field temperature:
Design DO concentration
Oxygen transfer correction factor
Salinity surface tension correction fact
Diffuser fouling factor
130.65
kg/day

m
m
m
m
%
%
Nm3/day
hr
Nm3/hr/basin
Nm3/hr
Nm3/hr
No.
No.
No.

9.17
9.08
3
0.8
0.95
0.9
1 131.9491645017

mg/l
mg/l
mg/l
mg/l

N m3/hr
nos
nos

As per CPEEHO Sewage manual the range is 0.250.35


Kg/day
Kg/day
m3/day
mg/l
m3
mg/l

m3/day
m3/m2.day(Ranges 816, Refer page 687, Table 87, Matcalf Eddy)
m2
m
m
m
m
kg/day
kg/m2.day <120 Hence OK(Refer page 687, Table 87, Matcalf Eddy)
hrs
m3/m.day<185 Hence OK(Refer Sewage Manual)
m(15% to 20% of clarifier dia)

m3/day
m3/hr

Metcalf Eddy page 429

Refer Table D1 Appendix D


Metcalf
Refer Table D1 Appendix D
Eddy
Metcalf
0.4 topage:1745
0.8 for diffused system and 0.6 to 1.2 for mechanical system
Eddy
page:1745
0.7 to 0.98
0.65 to 0.9