Вы находитесь на странице: 1из 7

ALAINSTADIUM&MIXEDUSEDEVELOPMENTPHASE1.

1of7+2
.

TITLE

INSPECTION&TESTPLANFOR

Ref.No.

: ITPMEP08

Rev.No.

: 0

INSTALLATIONOFTELEPHONE&DATASYSTEM Date

: 12.08.2012

ALAINSTADIUM&MIXEDUSEDEVELOPMENTPHASE1.1

INSPECTION&TESTPLANFOR
INSTALLATIONOFTELEPHONE&DATASYSTEM

ITPMEP08

ALAINSTADIUM&MIXEDUSEDEVELOPMENTPHASE1.1

2of7+2
.

TITLE

INSPECTION&TESTPLANFOR

Ref.No.

: ITPMEP08

Rev.No.

: 0

INSTALLATIONOFTELEPHONE&DATASYSTEM Date
MAINCONTRACTOR:
BAMINTERNATIONAL

SUBCONTRACTOR:
ETA

: 12.08.2012

ALAINSTADIUM&MIXEDUSEDEVELOPMENTPHASE1.1

3of7+2
.

TITLE

INSPECTION&TESTPLANFOR

Ref.No.

: ITPMEP08

Rev.No.

: 0

INSTALLATIONOFTELEPHONE&DATASYSTEM Date

: 12.08.2012

REVISIONRECORD

Thiscoverpageisarecordofallrevisionsofthedocumentidentifiedabovebynumberandtitle.Allpreviouscover
pagesareherebysupersededandaretobedestroyed.

Thecontractorhasthefullrighttomodify,amendorchangeMethodStatementandsupportingdocumentsasrequired
orasdeemednecessary.Allsuchdocumentswillbesubmittedtothe"Consultant's"forapproval.

Rev.
No.

Date

Prepd'By

00

12.08.12

AJEES

Chkd'By
BAMApproval DescriptionandPageNumbersofRevisions

ANA

MAINCONTRACTOR:

SUBCONTRACTOR:

ALAINSTADIUM&MIXEDUSEDEVELOPMENTPHASE1.1

4of7+2
.

TITLE

INSPECTION&TESTPLANFOR

Ref.No.

: ITPMEP08

Rev.No.

: 0

INSTALLATIONOFTELEPHONE&DATASYSTEM Date
BAMINTERNATIONAL

ETA

: 12.08.2012

INSPECTION TEST PLAN


AL AIN STADIUM & MIXED USE DEVELOPMENT PHASE 1.1

REF. No. : ITP-MEP-08


REV. No.: 0
DATE
: 12.08.12

INSPECTION & TEST PLAN FOR


INSTALLATION OF TELEPHONE & DATA SYSTEM
AREA

LEVEL

ITEM NO.
1

DESCRIPTION

SPECIFICATION / CRITERIA

Document Approvals
Material Approvals

Material submittals

Quality Documents

Method Statement ref. MS-MEP-08


Quality Control Procedure ref. QCP-MEP-08

INSPECTION & ACCEPTANCE


ETA
BAM
CON

Materials Verification

Approved material submittals

Inspection of Materials Received at site

Project Specification

Storage

Manufacturer's Recommendations &


Method Statement no.MS-MEP-08

Installation
Safety Clearance

Project Safety Plan

Installation

Project Specification
Method Statement ref. MS-MEP-08
Approved shop drawings

VERIFYING
DOCUMENT

Project Specification
Inspection for Installation of Telephone &
Data System

of the area
MEP-08

Approved shop drawings


Mehtod statement MS-

FM-MEP-08A

INSPECTION TEST PLAN


AL AIN STADIUM & MIXED USE DEVELOPMENT PHASE 1.1

REF. No. : ITP-MEP-08


REV. No.: 0
DATE
: 12.08.12

INSPECTION & TEST PLAN FOR


INSTALLATION OF TELEPHONE & DATA SYSTEM
AREA

LEVEL

ITEM NO.
4

DESCRIPTION

INSPECTION & ACCEPTANCE


ETA
BAM
CON

SPECIFICATION / CRITERIA

Cleaning Protection
Cleaning on completion of the activity

Method statement No. MS-MEP-08

Protection (if required) against possible

Method statement No. MS-MEP-08

damages till Commissioning/Handing-over


5

VERIFYING
DOCUMENT

Document Review
Site Inspection Reports

Signed & Approved

Test Certificates (if applicable)


Pressure Test Report (if applicable)
NCRs (if any)

Handed-over
Signed & Approved
All NCRs Closed & Signed off

H
H
H

R
R
R

R
R
R

LEGEND :

H - HOLD FOR INSPECTION

W - WITNESS INSPECTION

SUBCONTRACTOR :

ETA APPROVAL

BAM APPROVAL

CONSULTANT APPROVAL

NAME :

NAME

NAME :

SIGN

SIGN

SIGN

DATE

DATE

DATE

ETA

S - SURVEILLANCE INSPECTION

- REVIEW

Вам также может понравиться