SMCsProviding Unmatched
Intelligent Motor Control
SMC-Flex, SMC-3 and SMC-Delta
The Allen-Bradley SMC softstarters, from
complete Automation supplier Rockwell
Automation, provide integrated features
and technology previously unavailable in a
softstarter. The flexibility and capabilities of
the SMC-Flex, SMC-3, and SMC-Delta make
them ideal for virtually any application. The
same high-grade quality and functionality
found in the original SMC products exist
today in the SMC-Flex, SMC-3, and
SMC-Delta. And with the available options,
functionality, and application capabilities,
they are unmatched in the industry.
Voltage Range
Product Rating
5
25
43
60
85
108
135
201
251
317
361
480
Line Current
5
25
43
60
85
108
135
201
251
317
361
480
Delta Current
9
43
74
104
147
187
234
348
435
549
625
831
Control Voltage
Compact Size
The SMC-Flex integrates a bypass to
minimize heat generation during run time.
The bypass automatically closes when the
motor reaches its nominal speed, resulting in
a cooler-running component and reduction in
enclosure size.
Features
Soft Start
Soft Stop
Current Limit
Full Voltage
Kick Start
Preset Slow Speed
Linear Speed Start and Stop
Dual Ramp
Pump Start and Stop
Smart Motor Braking
Accu-Stop
Slow Speed with Braking
Standard
Pump
Control
Braking
Control
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Overload
Flexibility in Trip Class (10, 15, 20, 30, Off)
Reset Operation (Manual or Automatic)
Diagnostics
Ground Fault
PTC
Power Loss
Line Fault
Phase Reversal
Voltage Imbalance
Overvoltage
Undervoltage
Open Gate
Overtemperature
Excessive Starts per Hour
Overload
Configurable Auxiliary Contacts - 4
Normal, Up-to-speed, External bypass,
Fault, Alarm, Network Control
N.O. or N.C.
Motor Control
Standard Squirrel-Cage Induction Motor
Star-Delta Motor
Communication
DeviceNet, ControlNet, EtherNet, Remote I/O,
RS-485, Profibus, Interbus
Metering
Three-phase Voltages
Three-phase Currents
Power Usage in kWH
Power in kW
Power Factor of the
Motor Thermal
Running Motor
Capacity Usage
Elapsed Time of
Motor Operation
I/O
2 Inputs
4 Configurable Auxiliary Contacts
Line Connection
Motor Connection
Starting Modes
1/L1
3/L2
2/T1
5/L3
4/T2
6/T3
Delta Connections
1/L1
12/T6
2/T1
3/L2
8/T4
4/T2
M
3~
5/L3
10/T5
6/T3
Unsurpassed Advantages
Features
Benefits
Built-in Overload
Integral Bypass
Reduced footprint
Minimal heat loss
Reduced enclosure size
Reduced total cost
Reduction in inventory
Cost savings
LCD Display
Product Modularity
Ease of maintenance
Configurable to:
Normal/Up-to-speed/External bypass/
Fault/Alarm/Network Control
N.O./N.C.
Current Range
Product Rating
3
9
16
19
25
30
37
43
60
85
108
135
Line Current
3
9
16
19
25
30
37
43
60
85
108
135
Delta Current
187 1
2341
SMC-3
Voltage Range
200600 VAC 50/60Hz
Control Voltage
100240 VAC or 24 VAC/DC
Starting Modes
Features
Typical
Applications
Motor
Soft Start, Kick Start,
Current Limit Start, or Soft Stop
Overload Protection
Flexibility in trip class (10, 15, 20 or OFF)
Selectable overload reset (Manual or Automatic)
FAULT Diagnostics
Overtemperature in power section
Phase reversal (selectable)
Phase loss / Open load
Phase imbalance
Shorted SCRs
Lifts
Chillers
Pumps
Unsurpassed Advantages
Features
Overload
Built-in Overload
True 3-Phase Control
Advanced Diagnostics
Digital Adjustments
Add-on Configurable
Auxiliary Contacts
Compact Size
LED Display
An LED display clearly relays device
status information including RUN,
FAULT diagnostics, and OFF.
The SMC-3 has a line of side-mount configurable
(Normal or Up-to-Speed) auxiliary contacts, allowing
you more flexibility than ever before in your smart
motor controller application.
SMC-Delta
The Industrys First Fully Integrated
Starter for Star-Delta Applications
Space requirement
with SMC-Delta
SMC-Delta
Space requirement
with traditional
Star-Delta-Starting
Motor
3~
SMC-Delta Softstarter
600
600
600
%
Full
Load 300
Current
%
Full
Load 300
Current
%
Full 350
Load
Current
Run
0
% Speed
Open Transition
100
Run
Run
100
100
100
% Speed
Closed Transition
100
100
% Speed
Cost-Saving Design
Benefits of the SMC-Delta over
traditional electromechanical solutions:
Compact design allows three times more starters in the same
panel space as with one traditional electromechanical device
Increased reliability
- Diagnostic features help prevent downtime
- Minimizes system mechanical and electrical
stress by reducing current surges
Simple Installation
- Only one product to purchase and install
- Integrated overload protection
- Internal Timer
- No internal wiring between contactors
Current
Range
Voltage
Range
Control
Voltage
Starting
Modes
Product Rating
3
9
16
20
25
32
51
64
74
104
147
LED Display
Current Limit Start
Features
Overload Protection
Typical
Applications
Compressors
Fans
Conveyors
Lifts
Chillers
Pumps
Power Pole
Feed-Through Wiring
DPI Communications
(same as Powerflex Drives)
Programmer and
Backlit LCD
Ease of Maintenance
Modular Power Structure
Removable Control Module
Changeable Fan Assembly
Protection
Power termination covers - IP2X
Advanced Diagnostics
PTC Input
Ground Fault Detection Additional Current
Transformer required Catalog Number 825-CBCT
Communication
Control Module
10
Power Structure
Modularizing Accessories
for the SMC-3 and SMC-Delta
Flexible and
Configurable
Auxiliary Contacts
Available configurations
IEC
Easy-to-mount side-mount
auxiliary contact blocks
1-N.O.
2-N.O.
Available in a variety of
contact combinations
1-N.C.
NEMA
Protected for
best performance
Optional MOV
protective modules
prevent damage from
transient voltages.
Reduce Temperature,
Increase Duty Cycle
Optional fan is useful if an
application requires an increased
duty cycle
Snap-on fan module runs silently
and is easy to install
Fan is installed as standard for 43... 135 A
SMC-3 and 74...147A SMC-Delta
No additional wiring
Build a Modular
Control System
Remote Reset
Solenoid
SMC-3
SMC-DELTA
Soft Start
By reducing starting torque surges, Soft Start
provides smooth, stepless motor acceleration
while minimizing damage to gears, couplings
and belts.
100
Voltage
Initial
Torque
Start
Soft Stop
The Soft Stop option extends the stopping
time to minimize load shifting or spillage.
Run
100
Motor Speed
Run
Start
Coast
Soft Stop
600
% of FLC
50
Limit Start.
Start
Full-Voltage Start
In the Full-Voltage Start mode, the SMC
performs like a solid-state contactor, achieving
full in-rush current and locked rotor torque.
12
100
Voltage
Run
100
Kickstart
(when selected)
Voltage
Initial
Torque
Start
Run
100
Motor Speed
7% or 15%
Stop
10% or 20%
100
Motor Speed
Run
Start
Linear Stop
With this type of acceleration mode, a closedloop feedback system maintains the motor
acceleration at a constant rate. The required
feedback signal is provided by a DC tachometer
coupled to the motor (tachometer supplied
separately).
Note: This mode is also available with Kickstart.
Ramp 2
Voltage
Ramp 1
Start 1
Start 2
Run
Motor Speed
100
Pump Start
Run
Pump Stop
13
SMB Smart
Motor Braking
100
Motor Speed
Coast to Rest
Start
Accu-Stop
Position Control
Run
Stop
Braking
100
Slow Speed
7% or 15%
Motor Speed
Slow Speed
Slow Speed
Braking/Coast
Slow
Speed
Start
Start
Run
Accu-Stop
100
7% or 15%
Motor Speed
Braking
Coast to Rest
Slow
Speed
Start
Run
Stop
SMC-2 Smart
Motor Controller
150-SG001 1-US-P
1
14
SMC Dialog
Plus Controller
Bulletin 150
SMC Flex
Controller
SMC-3
Controller
SMC-Delta
Controller
200600V
1480 A
200600V
1135 A
200600V
1147 A
Soft Start
Kickstart
Current Limit
Full Voltage
Soft Stop
Pump Control
Linear Speed
Features
Accu-Stop
Motor Protection
Communication
Metering
Keypad Programming/
LCD Display
108135 A Only
Page 21
Page 35
Page 50
15
Bulletin 150
y DPI Communication
y LCD Display
y Keypad Programming
y Four Programmable Auxiliary
Contacts
Standards Compliance/Approvals
y UL 508
y EN/IEC 60947-4-2
y cULus Listed (Open Type) (File No. E96956)
y CE Marked (Open Type) per EMC Directive and Low Voltage Directive
Modes of Operation
The SMC-Flex controller provides the following modes of operation
as Standard:
Soft Start
This method covers the most general applications. The motor is
given an initial torque setting, which is user adjustable. From the
initial torque level, the output voltage to the motor is steplessly
increased during the acceleration ramp time, which is user
adjustable.
Selectable Kickstart
The kickstart feature provides a boost at startup to break away
loads that may require a pulse of high torque to get started. It is
intended to provide a current pulse, for a selected period of time.
16
Table of Contents
Description of
Features.........................
Cat. No. Explanation
Product Selection ......
Options ..........................
Accessories..................
Specifications..............
Approximate
Dimensions and
Shipping Weights.......
19
20
21
25
26
27
30
Bulletin 150
Soft Stop9
The Soft Stop option can be used in applications requiring an
extended stop time. The voltage ramp down time is use adjustable
from 0 to 120 seconds. The load will stop when the voltage drops to
a point where the load torque is greater than the motor torque.
17
Bulletin 150
Braking Control
SMB Smart Motor Braking7
This option provides motor braking for applications that require the
motor to stop faster than a coast to rest. Braking control, with
automatic zero speed shut off, is fully integrated into the compact
design of the SMC controller. This design facilitates a clean, straight
forward installation and eliminates the requirement for additional
hardware such as braking contactors, resistors, timers, and speed
sensors. The microprocessor based braking system applies braking
current to a standard squirrel-cage induction motor. The strength of
the braking current is programmable from 150400% of full-load
current.
Accu-Stop7
This option is used in applications requiring controlled position
stopping. During stopping, braking torque is applied to the motor
until it reaches preset slow speed (7% or 15% of rated speed) and
holds the motor at this speed until a stop command is given.
Braking torque is then applied until the motor reaches zero speed.
Braking current is programmable from 0400% of full-load current.
Slow Speed Current is programmable from 0450% of full-load
current. Slow speed can be programmed for either 7% (low) or 15%
(high).
Slow Speed with Braking 7
Slow Speed with Braking is used on applications that require slow
speed (in the forward direction) for positioning or alignment and also
require braking control to stop. Slow speed adjustments are 7%
(low) or 15% (high) of rated speed. Slow speed acceleration current
is adjustable from 0450%. Slow speed running current is
adjustable from 0450% of full-load current. Braking current is
adjustable from 0400%.
18
Bulletin 150
y Power factor
y Motor thermal capacity usage
y Elapsed time
Note: The motor thermal capacity usage allows the user to monitor
the amount of overload thermal capacity usage before the
SMC-Flex controllers built-in electronic overload trips.
Built-in DPI Communication Capabilities
A serial interface port is provided as standard, which allows
connection to a Bulletin 20 Human Interface Module and a variety of
Bulletin 20-COMM Communication Modules. This includes AllenBradley Remote I/O, DeviceNet, ControlNet, Ethernet, ProfiBUS,
Interbus, and RS485-DF1.
LCD Display
The SMC-Flex controllers three-line 16-character backlit LCD
display provides parameter identification using clear, informative
text. Controller set up can be performed quickly and easily without
the use of a reference manual. Parameters are arranged in an
organized four-level menu structure for ease of programming and
fast access to parameters.
Keypad Programming
Programming of parameters is accomplished through a five-button
keypad on the front of the SMC-Flex controller. The five buttons
include up and down arrows, an Enter button, a Select button, and
an Escape button. The user needs only to enter the correct
sequence of keystrokes for programming the SMC-Flex controller.
Auxiliary Contacts
Four fully programmable hard contacts are furnished as standard
with the SMCFlex controller:
Aux #1, Aux #2, Aux #3, Aux #4
Undervoltage Protection
The SMC-Flex controllers undervoltage protection will halt motor
operation if a drop in the incoming line voltage is detected.
The undervoltage trip level is adjustable as a percentage of the
programmed line voltage, from 099%. To eliminate nuisance trips,
a programmable undervoltage trip delay time of 099 seconds can
also be programmed. The line voltage must remain below the
undervoltage trip level during the programmed delay time.
y N.O./N.C.
y Normal/Up-to-Speed/External Bypass/Fault/Alarm/Network
Overvoltage Protection
If a rise in the incoming line voltage is detected, the SMC-Flex
controllers overvoltage protection will halt motor operation.
The overvoltage trip level is adjustable as a percentage of the
programmed line voltage, from 0199%. To eliminate nuisance
trips, a programmable overvoltage trip delay time of 099 seconds
can also be programmed. The line voltage must remain above the
overvoltage trip level during the programmed delay time.
Network I/O
The SMC-Flex can have up to two (2) inputs and four (4) outputs
controlled via a communication network. The output contacts use
the auxiliary contacts.
Tach Input
A motor tachometer is required for the Linear Speed Start mode.
Please see the Specifications section page 22 for tachometer
characteristics.
PTC Input
A motor PTC input can be monitored by the SMC-Flex. In the event
of a fault, the SMC-Flex will shut down and indicate a motor PTC
fault.
19
Bulletin 150
150 F135
a
Combination
B 8L
f
152H F480
a
BD
Bulletin Number
Bulletin Number
B 59 8B
e
Code
Description
Code
Description
150
Solid-State Controller
152H
153H
Controller Ratings
Code
Controller Ratings
Description
F5
5 A, 0.53 Hp @ 460V AC
Code
Description
F25
25 A, 515 Hp @ 460V AC
F5
5 A, 0.53 Hp @ 460V AC
F43
43 A, 7.530 Hp @ 460V AC
F25
25 A, 515 Hp @ 460V AC
F60
60 A, 1040 Hp @ 460V AC
F43
43 A, 7.530 Hp @ 460V AC
60 A, 1040 Hp @ 460V AC
F85
85 A, 1560 Hp @ 460V AC
F60
F108
F85
85 A, 1560 Hp @ 460V AC
F135
F108
F201
F135
F251
F201
F317
F251
F361
F317
F480
F361
F480
Enclosure Type
Enclosure Type
Code
Description
Code
Description
Open
Open Type
Code
Description
HD
Code
Description
AD
BD
CD
Control Options
Code
Blank
Standard
Pump Control
Braking Control
e
Control Voltage
Description
Description
100240V AC
Horsepower
Code
Cat.
No.
Hp
Rating
Cat.
No.
Hp
Rating
Cat.
No.
Hp
Rating
Cat.
No.
Hp
Rating
Cat.
No.
Hp
Rating
33
0.5
39
46
40
52
150
60
450
34
0.75
40
7.5
47
50
54
200
61
500
Code
Description
35
41
10
48
60
56
250
62
600
Blank
Standard
36
1.5
42
15
49
75
57
300
63
700
Pump Control
37
43
20
50
100
58
350
65
800
Braking Control
38
44
25
51
125
59
400
67
1000
45
30
Code
Description
8L
Code
Description
8M
8L
8B
8M
8B
Load-side MOVs not available with Pump and Braking options, or on Deltaconnected motors.
MOVs can be field installed for open type units. For a listing of available
options, please see page 25.
20
Load-side MOVs not available with Pump and Braking options. For a listing
of available options, please see page 25.
Bulletin 150
200/208
230
400/415/460
500/575
Motor Current
(A)7
kW, 50Hz
Hp, 60 Hz
100240V AC 50/60 Hz
Control
Cat. No.
15
0.51
150-F5NBD
Cat. No.
150-F5NBR
150-F5FHD
5...25
1.55
150-F43NBD
150-F43NBR
150-F25FHD
8.6...43
310
150-F43NBD
150-F43NBR
150-F43FHD
12...60
515
150-F60NBD
150-F60NBR
150-F60FHD
17...85
525
150-F85NBD
150-F85NBR
150-F85FHD
27108
1030
150-F108NBD
150-F108NBR
150-F108FHD
34135
1540
150-F135NBD
150-F135NBR
150-F135FHD
100201
4060
150-F201NBD
150-F201NBR
150-F201FHD
125251
5075
150-F251NBD
150-F251NBR
150-F251FHD
158317
60100
150-F317NBD
150-F317NBR
150-F317FHD
180361
75125
150-F361NBD
150-F361NBR
150-F361FHD
240480
100150
150-F480NBD
150-F480NBR
150-F480FHD
15
0.181.1
0.51
150-F5NBD
150-F5NBR
150-F5FAD
5...25
1.15.5
1.57.5
150-F43NBD
150-F43NBR
150-F25FAD
8.6...43
2.211
315
150-F43NBD
150-F43NBR
150-F43FAD
12...60
315
520
150-F60NBD
150-F60NBR
150-F60FAD
17...85
5.522
7.530
150-F85NBD
150-F85NBR
150-F85FAD
27108
1130
1040
150-F108NBD
150-F108NBR
150-F108FAD
34135
1137
1550
150-F135NBD
150-F135NBR
150-F135FAD
100201
3755
4075
150-F201NBD
150-F201NBR
150-F201FAD
125251
4575
50100
150-F251NBD
150-F251NBR
150-F251FAD
158317
5590
60125
150-F317NBD
150-F317NBR
150-F317FAD
180361
75110
75150
150-F361NBD
150-F361NBR
150-F361FAD
240480
90132
100200
150-F480NBD
150-F480NBR
150-F480FAD
15
0.372.2
0.53
150-F5NBD
150-F5NBR
150-F5FBD
5...25
2.211
515
150-F25NBD
150-F25NBR
150-F25FBD
8.6...43
422
7.530
150-F43NBD
150-F43NBR
150-F43FBD
12...60
7.530
1040
150-F60NBD
150-F60NBR
150-F60FBD
17...85
1145
1560
150-F85NBD
150-F85NBR
150-F85FBD
27108
1555
2075
150-F108NBD
150-F108NBR
150-F108FBD
150-F135FBD
34135
18.575
25100
150-F135NBD
150-F135NBR
100201
75110
75150
150-F201NBD
150-F201NBR
150-F201FBD
125251
75132
100200
150-F251NBD
150-F251NBR
150-F251FBD
158317
90160
125250
150-F317NBD
150-F317NBR
150-F317FBD
180361
110200
150300
150-F361NBD
150-F361NBR
150-F361FBD
240480
160250
200400
150-F480NBD
150-F480NBR
150-F480FBD
1...5
0.552.2
0.753
150-F5NCD
150-F25NCR
150-F5FCD
5...25
315
520
150-F25NCD
150-F25NCR
150-F25FCD
8.6...43
5.522
7.540
150-F43NCD
150-F43NCR
150-F43FCD
12...60
7.537
1550
150-F60NCD
150-F60NCR
150-F60FCD
17...85
1155
1575
150-F85NCD
150-F85NCR
150-F85FCD
27108
18.575
25100
150-F108NCD
150-F108NCR
150-F108FCD
34135
3090
40125
150-F135NCD
150-F135NCR
150-F135FCD
100201
75132
100200
150-F201NCD
150-F201NCR
150-F201FCD
125251
90160
125250
150-F251NCD
150-F251NCR
150-F251FCD
158317
100200
200300
150-F317NCD
150-F317NCR
150-F317FCD
180361
132250
200350
150-F361NCD
150-F361NCR
150-F361FCD
240480
200315
250500
150-F480NCD
150-F480NCR
150-F480FCD
9 Controllers rated 108 A and greater are not equipped with line and load terminal lugs. See page 26 for terminal lug kits.
7 Motor FLA rating must fall within specified current range for unit to operate properly.
Hp ratings at motor terminal voltages for 200, 230, 460, and 575 line volts, respectively.
These controllers require a separate 100240V, 50/60 Hz single-phase control source. To add a control circuit transformer to the enclosure, add the appropriate
option code to the catalog string.
Separate 120V or 240V single phase is required for fan operation.
Line and load termination are provided as standard.
21
Bulletin 150
200/208
230
400/415/460
500/575
Hp7, 60 Hz
Cat. No.
Cat. No.
1.78.7
0.52
150-F5NBD
150-F5NBR
8.743
310
150-F25NBD
150-F25NBR
14.974
520
150-F43NBD
150-F43NBR
20.8104
7.530
150-F60NBD
150-F60NBR
29.4147
1040
150-F85NBD
150-F85NBR
47187
2060
150-F108NBD
150-F108NBR
59234
2075
150-F135NBD
150-F135NBR
174348
75100
150-F201NBD
150-F201NBR
218435
100150
150-F251NBD
150-F251NBR
275549
100200
150-F317NBD
150-F317NBR
313625
125200
150-F361NBD
150-F361NBR
415831
200300
150-F480NBD
150-F480NBR
1.78.7
0.372.2
0.52
150-F5NBD
150-F5NBR
8.743
2.211
315
150-F25NBD
150-F25NBR
14.974
422
525
150-F43NBD
150-F43NBR
20.8104
5.530
7.540
150-F60NBD
150-F60NBR
29.4147
1145
1550
150-F85NBD
150-F85NBR
47187
1555
2060
150-F108NBD
150-F108NBR
59234
18.575
2575
150-F135NBD
150-F135NBR
174348
55110
75125
150-F201NBD
150-F201NBR
218435
75132
100150
150-F251NBD
150-F251NBR
275549
90160
125200
150-F317NBD
150-F317NBR
313625
110200
150250
150-F361NBD
150-F361NBR
415831
160250
200350
150-F480NBD
150-F480NBR
1.78.7
0.754
15
150-F5NBD
150-F5NBR
8.743
422
7.530
150-F25NBD
150-F25NBR
14.974
7.537
1550
150-F43NBD
150-F43NBR
20.8104
1155
1575
150-F60NBD
150-F60NBR
29.4147
1575
25100
150-F85NBD
150-F85NBR
47187
3090
40150
150-F108NBD
150-F108NBR
59234
37132
50150
150-F135NBD
150-F135NBR
174348
110160
150250
150-F201NBD
150-F201NBR
218435
132250
200350
150-F251NBD
150-F251NBR
275549
160315
250450
150-F317NBD
150-F317NBR
313625
200355
300500
150-F361NBD
150-F361NBR
415831
250450
350700
150-F480NBD
150-F480NBR
1.78.7
1.15.5
17.5
150-F5NCD
150-F5NCR
8.743
5.515
7.540
150-F25NCD
150-F25NCR
14.974
1145
1560
150-F43NCD
150-F43NCR
20.8104
1555
20100
150-F60NCD
150-F60NCR
29.4147
2290
30150
150-F85NCD
150-F85NCR
47187
37132
50150
150-F108NCD
150-F108NCR
59234
45160
60200
150-F135NCD
150-F135NCR
174348
132250
200350
150-F201NCD
150-F201NCR
218435
160315
250400
150-F251NCD
150-F251NCR
275549
200400
300500
150-F317NCD
150-F317NCR
313625
250450
350600
150-F361NCD
150-F361NCR
415831
315560
400900
150-F480NCD
150-F480NCR
9 Controllers rated 108 A and greater are not equipped with line and load terminal lugs. See page 26 for terminal lug kits.
7 Hp ratings at motor terminal voltages for 200, 230, 460, and 575 line volts, respectively.
Motor FLA rating must fall within specified current range for unit to operate properly.
Separate 120V or 240V single phase is required for fan operation.
22
Current Rating
(A)9
Bulletin 150
Rated Voltage
[V AC]
200
230
Hp, 60 Hz
Controller Current
Rating 7
Cat. No.
Cat. No.
0.5
5A
152H-F5FHD-33
153H-F5FHD-33
0.75
5A
152H-F5FHD-34
153H-F5FHD-34
5A
152H-F5FHD-35
153H-F5FHD-35
1.5
25 A
152H-F25FHD-36
153H-F25FHD-36
25 A
152H-F25FHD-37
153H-F25FHD-37
25 A
152H-F25FHD-38
153H-F25FHD-38
25 A
152H-F25FHD-39
153H-F25FHD-39
7.5
25 A
152H-F25FHD-40
153H-F25FHD-40
10
43 A
152H-F43FHD-41
153H-F43FHD-41
15
60 A
152H-F60FHD-42
153H-F60FHD-42
20
85 A
152H-F85FHD-43
153H-F85FHD-43
25
85 A
152H-F85FHD-44
153H-F85FHD-44
30
108 A
152H-F108FHD-45
153H-F108FHD-45
40
135 A
152H-F135FHD-46
153H-F135FHD-46
50
201 A
152H-F201FHD-47
153H-F201FHD-47
60
201 A
152H-F201FHD-48
153H-F201FHD-48
75
251 A
152H-F251FHD-49
153H-F251FHD-49
100
317 A
152H-F317FHD-50
153H-F317FHD-50
125
361 A
152H-F361FHD-51
153H-F361FHD-51
150
480 A
152H-F480FHD-52
153H-F480FHD-52
0.5
5A
152H-F5FAD-33
153H-F5FAD-33
0.75
5A
152H-F5FAD-34
153H-F5FAD-34
5A
152H-F5FAD-35
153H-F5FAD-35
1.5
25 A
152H-F25FAD-36
153H-F25FAD-36
25 A
152H-F25FAD-37
153H-F25FAD-37
25 A
152H-F25FAD-38
153H-F25FAD-38
25 A
152H-F25FAD-39
153H-F25FAD-39
7.5
25 A
152H-F25FAD-40
153H-F25FAD-40
10
43 A
152H-F43FAD-41
153H-F43FAD-41
15
43 A
152H-F43FAD-42
153H-F43FAD-42
20
60 A
152H-F60FAD-43
153H-F60FAD-43
25
85 A
152H-F85FAD-44
153H-F85FAD-44
30
85 A
152H-F85FAD-45
153H-F85FAD-45
40
108 A
152H-F108FAD-46
153H-F108FAD-46
50
135 A
152H-F135FAD-47
153H-F135FAD-47
60
201 A
152H-F201FAD-48
153H-F201FAD-48
75
201 A
152H-F201FAD-49
153H-F201FAD-49
100
251 A
152H-F251FAD-50
153H-F251FAD-50
125
317 A
152H-F317FAD-51
153H-F317FAD-51
150
361 A
152H-F361FAD-52
153H-F361FAD-52
200
480 A
152H-F480FAD-54
153H-F480FAD-54
9 These controllers require a separate 100240V, 50/60 Hz single-phase control source. To add a control circuit transformer to the enclosure, add the
23
Bulletin 150
Rated Voltage
[V AC]
460
575
Hp, 60 Hz
Controller Current
Rating 7
Cat. No.
Cat. No.
0.5
5A
152H-F5FBD-33
153H-F5FBD-33
0.75
5A
152H-F5FBD-34
153H-F5FBD-34
5A
152H-F5FBD-35
153H-F5FBD-35
1.5
5A
152H-F5FBD-36
153H-F5FBD-36
5A
152H-F5FBD-37
153H-F5FBD-37
5A
152H-F5FBD-38
153H-F5FBD-38
25 A
152H-F25FBD-39
153H-F25FBD-39
7.5
25 A
152H-F25FBD-40
153H-F25FBD-40
10
25 A
152H-F25FBD-41
153H-F25FBD-41
15
25 A
152H-F25FBD-42
153H-F25FBD-42
20
43 A
152H-F43FBD-43
153H-F25FBD-43
25
43 A
152H-F43FBD-44
153H-F43FBD-44
30
43 A
152H-F43FBD-45
153H-F43FBD-45
40
60 A
152H-F60FBD-46
153H-F60FBD-46
50
85 A
152H-F85FBD-47
153H-F85FBD-47
60
85 A
152H-F85FBD-48
153H-F85FBD-48
75
108 A
152H-F108FBD-49
153H-F108FBD-49
100
135 A
152H-F135FBD-50
153H-F135FBD-50
125
201 A
152H-F201FBD-51
153H-F201FBD-51
150
201 A
152H-F201FBD-52
153H-F201FBD-52
200
251 A
152H-F251FBD-54
153H-F251FBD-54
250
317 A
152H-F317FBD-56
153H-F317FBD-56
300
361 A
152H-F361FBD-57
153H-F361FBD-57
350
480 A
152H-F480FBD-58
153H-F480FBD-58
400
480 A
152H-F480FBD-59
153H-F480FBD-59
0.75
5A
152H-F5FCD-34
153H-F5FCD-34
5A
152H-F5FCD-35
153H-F5FCD-35
1.5
5A
152H-F5FCD-36
153H-F5FCD-36
5A
152H-F5FCD-37
153H-F5FCD-37
5A
152H-F5FCD-38
153H-F5FCD-38
25 A
152H-F25FCD-39
153H-F25FCD-39
7.5
25 A
152H-F25FCD-40
153H-F25FCD-40
10
25 A
152H-F25FCD-41
153H-F25FCD-41
15
25 A
152H-F25FCD-42
153H-F25FCD-42
20
43 A
152H-F43FCD-43
153H-F43FCD-43
25
43 A
152H-F43FCD-44
153H-F43FCD-44
30
43 A
152H-F43FCD-45
153H-F43FCD-45
40
43 A
152H-F43FCD-46
153H-F43FCD-46
50
60 A
152H-F60FCD-47
153H-F60FCD-47
60
85 A
152H-F85FCD-48
153H-F85FCD-48
75
85 A
152H-F85FCD-49
153H-F85FCD-49
100
108 A
152H-F108FCD-50
153H-F108FCD-50
125
135 A
152H-F135FCD-51
153H-F135FCD-51
150
201 A
152H-F201FCD-52
153H-F201FCD-52
200
201 A
152H-F201FCD-54
153H-F201FCD-54
250
251 A
152H-F251FCD-56
153H-F251FCD-56
300
317 A
152H-F317FCD-57
153H-F317FCD-57
350
361 A
152H-F361FCD-58
153H-F361FCD-58
400
480 A
152H-F480FCD-59
153H-F480FCD-59
450
480 A
152H-F480FCD-60
153H-F480FCD-60
500
480 A
152H-F480FCD-61
153H-F480FCD-61
9 These controllers require a separate 100240V, 50/60 Hz single-phase control source. To add a control circuit transformer to the enclosure, add the
24
Bulletin 150
Braking Control
Description
Provides smooth motor acceleration and deceleration, reducing surges caused by the starting
and stopping of centrifugal pumps. Starting time is adjustable from 030 seconds, and
stopping time is adjustable from 0120 seconds.
Provides Smart Motor Braking (SMB), Accu-Stop, and Slow Speed with Braking.
Line Voltage
Cat. No.
Modification
480V
B9
600V
480V
D9
600V
Enclosed Options
Option
Push Buttons
Selector Switch
Pilot Lights
Description
Cat. No.
Modification
-1
-1F
1XA
1XB
1XC
1XD
1XE
Emergency Stop
-1E
Fault Reset
-FR
-4_
-5_
-6P
-6PX
-6PK
-6PL
-6PM
Communication Module
Disconnect Auxiliary
Circuit Breaker Auxiliary
-3
-3B
-8L
-8M
-8B
-HC3
Remote I/O
-20R
RS-485
-20S
DeviceNet
-20D
Ethernet/IP
-20E
Control Net
-20C
-98
-99
-98X
-99X
-SEL
U.L. Label
U.L. Label
-UL
-OPS
9 Add the designated letter to the end of the cat. no. Example: To add the Pump Control option: Cat. No. 150-F361NBDB or Cat. No. 152H-F361FBDB-57.
7 Option push buttons are available only when the corresponding option module is selected. Example: Cat. No. 150-F108FBDB-1XB.
Specify pilot light lens color. Options: Green or Red. Example: -4R for a red lens.
Bypass contactor and overload are not included with this option. A -NB and -OL need to be added to the catalog string to add these devices.
25
Bulletin 150
Field Modification
Cat. No.
Description
585
150-F84
108480
585
150-F84L
150-F86
108480
150-F86L
9 The same protective module mounts on the line or load side of the SMC-Flex. For applications requiring both line and load side protection, two protective
Line Side
Load Side
Pkg. Qty.
Cat. No.
199-LF1
3
199-LG1
Field Modification
Cat. No.
Terminal Covers
IEC line or load terminal covers for 108135 A devices.
Dead front protection
150-TC1
Terminal Covers
IEC line or load terminal covers for 201251 A devices.
Dead front protection
150-TC2
Terminal Covers
IEC line or load terminal covers for 317480 A devices.
Dead front protection
150-TC3
Description
585 A units have terminal guards standard. No additional terminal guards are required.
Hand Held
Human Interface Modules
Door Mounted
Human Interface Modules
Cat. No.
20-HIM-A2
20-HIM-A3
20-HIM-A4
20-HIM-A5
20-HIM-C3
20-HIM-C5S
20-HIM-H10
1202-H03
1202-H10
1202-H30
1202-H90
Description (IP30/Type 1)
DriveTools
1203-S03
Remote I/O
20-COMM-R
RS-485/DF1
20-COMM-S
ProfiBUS
20-COMM-P
ControlNet
20-COMM-C
Interbus
DeviceNet
20-COMM-I
20-COMM-D
Ethernet/IP
20-COMM-E
RS485 HVAC
20-COMM-H
Lonworks
20-COMM-L
ControlNet (Fiber)
20-COMM-Q
Programming Software
26
20-HIM-C5
Communication Modules
20-HIM-C3S
Personal Computer
9303-3CS0EFF
Bulletin 150
Setup
Standard Features
Power Wiring
Control Wiring
Keypad
Software
Parameter values can be downloaded to the SMC-Flex Controller with DriveTools programming
software and the Cat. No. 20-COMM DPI communication module.
Communications
One DPI provided for connection to optional human interface and communication modules.
Soft Start
Current Limit Start
Dual Ramp
Full Voltage
Linear Speed Acceleration
Preset Slow Speed
Soft Stop
Power loss, line fault, voltage unbalance, excessive starts/hour, phase reversal, undervoltage,
overvoltage, controller temp, stall, jam, open gate, overload, underload, communication fault.
Metering
Amps, volts, kW, kWH, elapsed time, power factor, motor thermal capacity usage.
Alarm Contact
Overload, underload, undervoltage, overvoltage, unbalance, jam, stall, and ground fault
Status Indication
Auxiliary Contacts
Pump Control
Helps reduce fluid surges in centrifugal pumping systems during starting and stopping period.
Starting time is adjustable from 030 seconds. Stopping time is adjustable from 0120 seconds.
SMB Smart
Motor Braking
Provides motor braking without additional equipment for applications that require the motor to
stop quickly. Braking current is adjustable from 0400% of the motors full-load current rating.
Accu-Stop
Provides controlled position stopping. During stopping, braking torque is applied to the motor
until it reaches preset slow speed (7% or 15% of rated speed) and holds the motor at this speed
until a stop command is given. Braking torque is then applied until the motor reaches zero speed.
Braking current is programmable from 0450% of full-load current.
Optional Features
Braking Control
Slow Speed with Used on applications that require slow speed (in the forward direction) for positioning or alignment
Braking
and also require braking control to stop.
9 Customer supplied.
27
Bulletin 150
Short Circuit
Protection
5
25
43
60
85
108
135
201
251
317
361
480
8.7
43
74
104
147
187
234
348
435
549
625
831
Control Circuit
UL/CSA/NEMA
IEC
200480V AC
200415V
200600V AC (15%, +10%)
200500V
N/A
500V
N/A
6000V
2200V AC
2500V
200480V AC: 1400V
200415V: 1400V
200600V AC: 1600V
200500V: 1600V
50/60 Hz
50/60 Hz
MG 1
AC-53b:3.0-50:1750
N/A
IP20 (585 A)/IP00 (108480 A)
RC Snubber Network
Metal Oxide Varistors: 220 Joules
Type 1
Max. Circuit Breaker
Max. Available Fault
Max. Available Fault
Max. Fuse (A)7
(A)
10 kA
20
10 kA
20
10 kA
100
10 kA
100
10 kA
150
10 kA
150
10 kA
225
10 kA
225
10 kA
300
10 kA
300
18 kA
400
18 kA
300
18 kA
500
18 kA
400
30 kA
600
30 kA
600
30 kA
700
30 kA
700
42 kA
800
30 kA
800
42 kA
1000
30 kA
1000
42 kA
1200
30 kA
1200
10 kA
35
10 kA
35
10 kA
150
10 kA
150
10 kA
300
10 kA
300
10 kA
400
10 kA
300
10 kA
400
10 kA
400
18 kA
500
18 kA
500
18 kA
700
18 kA
700
30 kA
1000
30 kA
1000
42 kA
1200
30 kA
1200
42 kA
1600
30 kA
1600
42 kA
1600
30 kA
1600
42 kA
1600
30 kA
1600
100240V AC
100240V
24V AC/24V DC
24V AC/24V DC
N/A
240V
N/A
3000V
1600V AC
2000V
50/60 Hz
50/60 Hz
N/A
IP20
85V AC, 19.2V DC / 20.4V AC
20 mA @120V AC/40 mA @ 240V AC, 7.6 mA @ 24V AC/DC
50V AC, 10V DC / 12V AC
Control Module
Power
Requirements
Auxiliary Contacts
19/20 (Aux #1)
29/30 (Aux #2)
31/32 (Aux #3)
33/34 (Aux #4)
Tach Input
9 For devices rated 5480 A, heatsink fans can be powered by either 110/120V AC or 220/240V AC.
28
< 7.5V
30V
6
1500
800 ms
05V DC, 4.5V DC = 100% Speed
Bulletin 150
20+75 C
Altitude
Humidity
595% (non-condensing)
Pollution Degree
Mechanical
Resistance to Vibration
Operational
Non-Operational
Resistance to Shock
Operational
Non-Operational
Construction
Power Poles
585 A
Power Poles
108480 A
Control Modules
Metal Parts
585 A
Power Terminals
Terminals
108135 A
201251 A
317480 A
Control Terminals
M3 screw clamp
Other
EMC Emission Levels
Class A
Class A
Electrostatic Discharge
Radio Frequency Electromagnetic Field
Fast Transient
Surge Transient
8 kV Air Discharge
Per EN 60947-4-2
Per EN 60947-4-2
Per EN 60947-4-2
5
Current Range
Overload Characteristics
Delta
1.79
25
5...25
8.643
43
8.6...43
14.875
60
12...60
20.8104
85
17...85
29.4147
108
27108
47187
135
34135
59234
201
100201
174348
251
125251
218435
317
158317
275549
361
180361
313625
480
240480
Trip Classes
Trip Current Rating
Number of Poles
Approvals
Line
1...5
415831
10, 15, 20, and 30
117% of Motor FLC
3
29
Bulletin 150
Controller
Rating (A)
Height
Width
Depth
Weight
585
321
(12.6)
150
(5.9)
203
(8.0)
5.7 kg
(12.6 lbs)
108135
443.7
(17.47)
196.4
(7.74)
205.2
(8.08)
15.0 kg
(33 lbs).
201251
560
(22.05)
225
(8.86)
253.8
(9.99)
30.4 kg
(67 lbs).
317480
600
(23.62)
290
(11.42)
276.5
(10.89)
45.8 kg
(101 lbs)
Controller
Rating (A)
B Height
A Width
C Depth
Non-Combination Controller
5
610 (24)
406 (16)
254 (10)
25
610 (24)
406 (16)
254 (10)
43
610 (24)
406 (16)
254 (10)
60
610 (24)
406 (16)
254 (10)
85
610 (24)
406 (16)
254 (10)
108
762 (30)
610 (24)
305 (12)
135
762 (30)
610 (24)
305 (12)
201
965 (38)
762 (30)
356 (14)
251
965 (38)
762 (30)
356 (14)
317
1295 (51)
914 (36)
356 (14)
361
1295 (51)
914 (36)
356 (14)
480
1295 (51)
914 (36)
356 (14)
30 A/J
610 (24)
406 (16)
254 (10)
25
30 A/J
610 (24)
406 (16)
254 (10)
43
60 A/J
610 (24)
406 (16)
254 (10)
60
100 A/J
610 (24)
406 (16)
254 (10)
85
100 A/J
610 (24)
406 (16)
254 (10)
108
200 A/J
965 (38)
762 (30)
356 (14)
135
200 A/J
965 (38)
762 (30)
356 (14)
201
400 A/J
965 (38)
762 (30)
356 (14)
251
400 A/J
965 (38)
762 (30)
356 (14)
317
600 A/J
1524 (60)
965 (38)
356 (14)
356 (14)
361
480
600 A/J
1524 (60)
965 (38)
600 A/J
1524 (60)
965 (38)
356 (14)
800 A/L
2286 (90)
508 (20)
508 (20)
15 A
610 (24)
406 (16)
254 (10)
25
30 A
610 (24)
406 (16)
254 (10)
43
80 A
610 (24)
406 (16)
254 (10)
60
100 A
610 (24)
406 (16)
254 (10)
85
125 A
610 (24)
406 (16)
254 (10)
108
965 (38)
762 (30)
356 (14)
135
965 (38)
762 (30)
356 (14)
201
965 (38)
762 (30)
356 (14)
251
965 (38)
762 (30)
356 (14)
317
1295 (51)
914 (36)
356 (14)
361
1295 (51)
914 (36)
356 (14)
480
1295 (51)
914 (36)
356 (14)
30
Bulletin 150
B Height
A Width
C Depth
Non-Combination Controller
8.7
610 (24)
406 (16)
254 (10)
43
610 (24)
406 (16)
254 (10)
74
610 (24)
406 (16)
254 (10)
104
610 (24)
406 (16)
254 (10)
147
610 (24)
406 (16)
254 (10)
184
762 (30)
610 (24)
305 (12)
234
762 (30)
610 (24)
305 (12)
348
965 (38)
762 (30)
356 (14)
435
965 (38)
762 (30)
356 (14)
549
1295 (51)
914 (36)
356 (14)
625
1295 (51)
914 (36)
356 (14)
831
1295 (51)
914 (36)
356 (14)
31
Bulletin 150
y Soft Start
y Current Limit Start
y Kick Start
y Soft Stop
y Coast-to-Rest
The controllers are available in twelve sizes: 3, 9, 16, 19, 25, 30, 37, 43, 60,
85, 108, and 135 A. They offer two voltage ranges: 200480V AC and
200600V AC. All voltage ranges will operate at either 50 or 60 Hz.
y 1135 A Range
y Built-In Electronic Motor Overload Protection
y Built-In SCR/Run Bypass
y Delta Connections for 108 A and 135 A Devices
Standards Compliance/Approvals
y UL 508
y CSA C22.2 No. 14
y EN/IEC 60947-4-2
y cULus Listed (Open Type) (File No. E96956)
y CE Marked (Open Type) per EMC Directive and Low Voltage Directive
Modes of Operation
Soft Start
This method has the most general application. The motor is raised from an
initial torque value to full voltage. This initial torque can be adjusted to
15%, 25%, 35%, or 65% of locked rotor torque. The motor voltage is
gradually increased during the acceleration ramp time, which can be
adjusted from 2, 5, 10, 15, 20, 25, or 30 s. (337 A, 215 s only)
32
Table of Contents
Cat. No. Explanation ............... 34
Product Selection..................... 35
Typical Wiring Diagrams ........ 38
Specifications............................. 40
Approximate Dimensions ...... 44
Enclosed Options ..................... 46
Accessories (SMC-3 and
SMC-Delta) ................................. 47
Bulletin 150
Description of Features
Electronic Motor Overload Protection
Phase Imbalance
Over-temperature
The SMC-3 monitors the SCR temperature by means of internal
thermistors. When the power poles maximum rated temperature is
reached, the microcomputer switches off the SMC, a TEMP fault is
indicated via LED, and the 97/98 fault contact closes.
Shorted SCR
Prior to every start and during starting, the unit will check all SCRs
for shorts and unit load connections to the motor. If there is a
shorted SCR in the SMC-3 and/or open load, the start will be
aborted and a shorted SCR or open load fault will be indicated. This
prevents damage from phase imbalance.
Push to Test
The unit with control wiring can be tested for fault conditions by
using the Push to Test function. Hold down the Reset button for 5
seconds to activate the fault Aux (97, 98) and shut down the SMC-3.
To clear, either push the Reset button or cycle control power to the
device.
Overload
Overtemperature
Phase Reversal
Phase Loss/Open Load
Phase Imbalance
Shorted SCR
Test
33
Bulletin 150
150 C
a
Combination
30
D 8L
f
152H C
a
BD
Description
Solid-State Controller
Code
Description
152H
153H
Controller Type
Controller Type
Code
Description
Code
Description
SMC-3
SMC-3
Ampere Ratings
Ampere Ratings
Code
Description
Code
Description
3A
3A
9A
9A
16
16 A
16
16 A
19
19 A
19
19 A
25
25 A
25
25 A
30
30 A
30
30 A
37
37 A
37
37 A
43
43 A
43
43 A
60
60 A
60
60 A
85
85 A
85
85 A
108
108 A
108
108 A
135
135 A
135
135 A
Enclosure Type
Enclosure Type
Code
Description
Code
Description
Open
e
Input Line Voltage
Open Type
e
Input Line Voltage
Open Type
Code
43 8L
Bulletin Number
Bulletin Number
150
F
a
a
Code
30
Description
Code
Description
HD
AD
BD
CD
f
Horsepower
f
Control Voltage
Code
Description
100240V AC
Code
Hp
Code
Hp
33
0.5
42
15
34
0.75
43
20
35
44
25
36
1.5
45
30
37
46
40
38
47
50
39
48
60
40
7.5
49
75
41
10
50
100
Options
Code
Description
8L
Options
34
Code
Description
8L
Bulletin 150
kW, 50 Hz
Rated Voltage
[V AC]
200/208
230
380/400/
415/460
500/575
Current
Rating (A)
Open Type
100240V
AC 50/60 Hz
Control
Starting Duty
24V AC/DC
Control
IP65 (Type
4/12)
Enclosed
NonCombination
Controllers 7
350%
450%
350%
450%
Cat. No.
Cat. No.
Cat. No.
13
0.5
0.5
150-C3NBD
150-C3NBR
150-C3FHD
39
0.752
0.751.5
150-C9NBD
150-C9NBR
150-C9FHD
5.316
1.53
1.53
150-C16NBD
150-C16NBR
150-C16FHD
6.319
1.55
1.53
150-C19NBD
150-C19NBR
150-C25FHD
9.227.7
37.5
35
150-C25NBD
150-C25NBR
150-C25FHD
1030
37.5
35
150-C30NBD
150-C30NBR
150-C30FHD
12.337
510
57.5
150-C37NBD
150-C37NBR
150-C37FHD
14.343
510
510
150-C43NBD
150-C43NBR
150-C43FHD
2060
7.515
7.515
150-C60NBD
150-C60NBR
150-C60FHD
28.385
1025
1025
150-C85NBD
150-C85NBR
150-C85FHD
27108
2030
2030
34135
2540
2540
13
0.55
0.37
0.5
0.5
150-C3NBD
150-C3NBR
39
2.2
1.5
0.752
0.752
150-C9NBD
150-C9NBR
150-C9FAD
5.316
1.55
1.53
150-C16NBD
150-C16NBR
150-C16FAD
150-C3FAD
6.319
25
23
150-C19NBD
150-C19NBR
150-C25FAD
9.227.7
5.5
37.5
35
150-C25NBD
150-C25NBR
150-C25FAD
1030
7.5
5.5
510
57.5
150-C30NBD
150-C30NBR
150-C30FAD
12.337
7.5
7.5
510
510
150-C37NBD
150-C37NBR
150-C37FAD
14.343
11
7.5
515
515
150-C43NBD
150-C43NBR
150-C43FAD
2060
15
11
7.520
7.520
150-C60NBD
150-C60NBR
150-C60FAD
28.385
22
18.5
1530
1530
150-C85NBD
150-C85NBR
150-C85FAD
27108
30
30
2040
2040
34135
37
37
2550
2550
13
1.1
0.75
0.51.5
0.51
150-C3NBD
150-C3NBR
39
1.55
1.53
150-C9NBD
150-C9NBR
150-C9FBD
5.316
7.5
5.5
510
57.5
150-C16NBD
150-C16NBR
150-C16FBD
150-C3FBD
6.319
7.5
5.5
510
510
150-C19NBD
150-C19NBR
150-C25FBD
9.227.7
11
9.5
7.515
7.510
150-C25NBD
150-C25NBR
150-C25FBD
1030
15
11
7.520
7.515
150-C30NBD
150-C30NBR
150-C30FBD
12.337
18.5
15
1025
1020
150-C37NBD
150-C37NBR
150-C37FBD
14.343
22
15
1030
1030
150-C43NBD
150-C43NBR
150-C43FBD
2060
30
22
1540
1540
150-C60NBD
150-C60NBR
150-C60FBD
28.385
45
37
2560
2560
150-C85NBD
150-C85NBR
150-C85FBD
27108
55
55
5075
5075
34135
75
75
60100
60100
13
1.5
1.1
0.752
0.751
150-C3NCD
150-C3NCR
39
5.5
37.5
35
150-C9NCD
150-C9NCR
150-C9FCD
5.316
7.5
7.5
510
510
150-C16NCD
150-C16NCR
150-C16FCD
150-C3FCD
6.319
11
7.5
7.515
7.510
150-C19NCD
150-C19NCR
150-C25FCD
9.227.7
15
11
7.520
7.515
150-C25NCD
150-C25NCR
150-C25FCD
1030
18.5
15
1025
1020
150-C30NCD
150-C30NCR
150-C30FCD
12.337
22
18.5
1530
1525
150-C37NCD
150-C37NCR
150-C37FCD
14.343
22
22
1540
1530
150-C43NCD
150-C43NCR
150-C43FCD
2060
37
37
2050
2040
150-C60NCD
150-C60NCR
150-C60FCD
28.385
55
45
3075
3060
150-C85NCD
150-C85NCR
150-C85FCD
27108
75
75
60100
60100
34135
90
90
75125
75125
9 Motor FLA rating must fall within specified current range for unit to operate properly.
7 These controllers require a separate 100240V, 50/60 Hz single-phase control source. To add a control circuit transformer to the enclosure, add the
appropriate option code to the catalog string.
35
Bulletin 150
kW
Rated Voltage
[V AC]
200/208
230
380/400/
415/460
500/575
Current
Rating (A)
Starting Duty
24V AC/DC
Control
Cat. No.
Cat. No.
350%
450%
350%
450%
47187
2060
2060
150-C108NBD 150-C108NBR
59234
2075
2075
150-C135NBD 150-C135NBR
47187
55
55
2060
2060
150-C108NBD 150-C108NBR
59234
75
75
2575
2575
150-C135NBD 150-C135NBR
47187
90
90
40150
40150
150-C108NBD 150-C108NBR
59234
132
132
50150
50150
150-C135NBD 150-C135NBR
47187
132
132
50150
50150
150-C108NCD 150-C108NCR
59234
160
160
60200
60200
150-C135NCD 150-C135NCR
9 Motor FLA rating must fall within specified current range for unit to operate properly.
36
Open Type
100240V
AC 50/60 Hz
Control
Bulletin 150
Rated Voltage
[V AC]
200/208
230
380/400/
415/460
500/575
Current
Rating (A)
Hp
(0.5 = 1/2, 0.75 = 3/4, 7.5 = 7-1/2)
0.5
0.75
152H-C9FHD-34
153H-C9FHD-34
152H-C9FHD-35
153H-C9FHD-35
1.5
152H-C9FHD-36
153H-C9FHD-36
152H-C16FHD-37
153H-C16FHD-37
16
152H-C16FHD-38
153H-C16FHD-38
25
152H-C25FHD-39
153H-C25FHD-39
37
7.5
152H-C37FHD-40
153H-C37FHD-40
43
10
152H-C43FHD-41
153H-C43FHD-41
60
15
152H-C60FHD-42
153H-C60FHD-42
85
20
152H-C85FHD-43
153H-C85FHD-43
85
25
152H-C85FHD-44
153H-C85FHD-44
108
30
152H-C108FHD-45
153H-C108FHD-45
135
40
152H-C135FHD-46
153H-C135FHD-46
Cat. No.
Cat. No.
152H-C3FHD-33
153H-C3FHD-33
0.5
152H-C3FAD-33
153H-C3FAD-33
0.75
152H-C9FAD-34
153H-C9FAD-34
152H-C9FAD-35
153H-C9FAD-35
1.5
152H-C9FAD-36
153H-C9FAD-36
152H-C9FAD-37
153H-C9FAD-37
16
152H-C16FAD-38
153H-C16FAD-38
25
152H-C25FAD-39
153H-C25FAD-39
30
7.5
152H-C30FAD-40
153H-C30FAD-40
37
10
152H-C37FAD-41
153H-C37FAD-41
43
15
152H-C43FAD-42
153H-C43FAD-42
60
20
152H-C60FAD-43
153H-C60FAD-43
85
25
152H-C85FAD-44
153H-C85FAD-44
85
30
152H-C85FAD-45
153H-C85FAD-45
108
40
152H-C108FAD-46
153H-C108FAD-46
135
50
152H-C135FAD-47
153H-C135FAD-47
0.5
152H-C3FBD-33
153H-C3FBD-33
0.75
152H-C3FBD-34
153H-C3FBD-34
152H-C3FBD-35
153H-C3FBD-35
1.5
152H-C9FBD-36
153H-C9FBD-36
152H-C9FBD-37
153H-C9FBD-37
152H-C9FBD-38
153H-C9FBD-38
16
152H-C16FBD-39
153H-C16FBD-39
16
7.5
152H-C16FBD-40
153H-C16FBD-40
25
10
152H-C25FBD-41
153H-C25FBD-41
30
15
152H-C30FBD-42
153H-C30FBD-42
37
20
152H-C37FBD-43
153H-C37FBD-43
43
25
152H-C43FBD-44
153H-C43FBD-44
43
30
152H-C43FBD-45
153H-C43FBD-45
60
40
152H-C60FBD-46
153H-C60FBD-46
85
50
152H-C85FBD-47
153H-C85FBD-47
85
60
152H-C85FBD-48
153H-C85FBD-48
108
75
152H-C108FBD-49
153H-C108FBD-49
135
100
152H-C135FBD-50
153H-C135FBD-50
0.75
152H-C3FCD-34
153H-C3FCD-34
152H-C3FCD-35
153H-C3FCD-35
1.5
152H-C9FCD-36
153H-C9FCD-36
152H-C9FCD-37
153H-C9FCD-37
152H-C9FCD-38
153H-C9FCD-38
152H-C9FCD-39
153H-C9FCD-39
16
7.5
152H-C16FCD-40
153H-C16FCD-40
16
10
152H-C16FCD-41
153H-C16FCD-41
25
15
152H-C25FCD-42
153H-C25FCD-42
30
20
152H-C30FCD-43
153H-C30FCD-43
37
25
152H-C37FCD-44
153H-C37FCD-44
43
30
152H-C43FCD-45
153H-C43FCD-45
43
40
152H-C43FCD-46
153H-C43FCD-46
60
50
152H-C60FCD-47
153H-C60FCD-47
85
60
152H-C85FCD-48
153H-C85FCD-48
85
75
152H-C85FCD-49
153H-C85FCD-49
108
100
152H-C108FCD-50
153H-C108FCD-50
135
125
152H-C135FCD-51
153H-C135FCD-51
7 These controllers require a separate 100240V, 50/60 Hz single-phase control source. To add a control circuit transformer to the enclosure, add the appropriate option code to the catalog
string.
37
Bulletin 150
NEMA
Three-Wire Configuration
IEC
38
NEMA
Bulletin 150
NEMA
Reversing Configuration
Note: Minimum Off time equals 1.0 s.
IEC
NEMA
39
Bulletin 150
Continuous
C3
C9
C16
C19
C25
C30
C37
C43
C60
C85
C108
C135
16
19
25
30
37
43
60
85
108
135
11
12
14
15
17
19
24
34
50
82
62
75
Cable size:
Tightening torque:
23 Nm
(200 in-lbs)
Cable size:
Tightening torque:
23 Nm
(200 in-lbs)
Control terminals
Cable size:
Tightening torque:
9A
16 A
19 A
25 A
30 A
37 A
43 A
60 A
13
39
5.316
6.319
9.227.
7
1030
12.33
7
14.34
3
2060
85 A
108 A
135 A
28.38
27108 34135
5
UL Class K5 Fuses
UL Listed Combination (600V)
UL Class K5 Fuses
UL Listed Combination (600V)
Fuse
Fuse
Fuse
Fuse
Fuse
Fuse
Fuse
10 kA
18 kA
225 A
5 kA
10 A
35 A
60 A
70 A
300 A
300 A
10 kA
100 A
110 A
125 A
150 A
225 A
300 A
400 A
10 kA
125 A
175 A
225 A
300 A
60 A
80 A
90 A
5 kA
6A
20 A
30 A
40 A
50 A
10 kA
18 kA
225 A
5 kA
15 A
35 A
60 A
70 A
300 A
300 A
10 kA
100 A
110 A
125 A
150 A
225 A
300 A
300 A
400 A
F45
F45
F45
5 kA
C25
C25
F45
F45
UL/cUL
IEC
200480V AC
200600V AC
200480V~ 400V~
500V~ 500V~
600V AC
500V~
Dielectric withstand
2200V AC
2500V~
200480V AC 1400V
200600V AC 1600V
200480V~ 1400V
500V~ 1600V
Operating frequency
50/60 Hz
50/60 Hz
137 A
AC-53b: 3.5-15:3585
4360 A
Utilization category
85 A
AC-53b: 4.5-30:1770
AC-53b: 4.5-30:3570
108 A
AC-53b: 4.5-30:1770
135 A
AC-53b: 3.5-30:1770
Number of poles
6 kV
1000V/s
DV/DT protection
Overvoltage category
III
III
Control Circuit
Rated operational voltage (+10%, 15%)
Rated insulation voltage
Rated impulse voltage
Dielectric withstand
UL/cUL
IEC
250V
250V~
4 kV
1500V AC
2000V~
Overvoltage category
III 9
Operating frequency
50/60 Hz
50/60 Hz
4385 A
108135 A
337 A
9 Overvoltage category II, when either control or auxiliary circuit is wired to a SELV or PELV circuit.
7 Use 175% of motor FLA. These fuses are time delay or Class J.
Consult local codes for proper sizing of short circuit protection.
40
300 A
18 kA
Repetitive peak
500 A
18 kA
Power Circuit
300 A
18 kA
Bulletin 150
UL/cUL
IEC
250V AC / 30V DC
250V~ / 30V DC
250V
250V~
4 kV
1500V AC
2000V~
Overvoltage category
III 9
Operating frequency
50/60 Hz
50/60 Hz
Utilization category
D300
AC15
Electromagnetic relay
Number of contacts
Type of contacts
TB-97, -98
Kind of current
(OVLD/Fault)
Rated operational current (max.)
AC/DC
1A
Make VA/break VA
432/72
Electromagnetic relay
Number of contacts
Type of contacts
TB-13, -14
(Normal/Up- Kind of current
to-Speed)
Rated operational current (max.)
1A
Make VA/break VA
432/72
Standard Features
2, 5, 10, or 15 s (3135 A)
20, 25, or 30 s (43135 A only)
137 A
Weight kg
4385 A
(lbs)
108135 A
0.86 (1.9)
2.25 (5)
15 (33)
Mechanical Design Specifications/Test Requirements
Resistance
to vibration
Operational
Non-operational
Resistance
to shock
Operational
Non-operational
30 G
Environmental
-550 C (23122 F) (open)
-540 C (23104 F) (enclosed)
Operating temperature
Storage temperature
-2585 C (-13185 F)
Altitude
Humidity
595% (non-condensing)
Pollution degree
Type of Protection
IP2X
Other
EMC
emission
levels
UL/cUL
IEC
Class A
Radiated emissions
Electrostatic discharge
EMC
immunity
levels
Class A
4 kV contact and 8kV air discharge
Fast transient
Surge transient
Wiring Diagrams
9 Overvoltage category II, when either control or auxiliary circuit is wired to a SELV or PELV circuit.
41
Bulletin 150
IEC
250V AC/30V DC
250V AC/30V DC
250V
250V AC
4 kV
Dielectric Withstand
1500V AC
2000V AC
Overvoltage Category
III 9
Operating Frequency
50/60 Hz
50/60 Hz
Utilization Category
C300/R150
No. of Contacts
Type of Contact
Current
AC/DC
2.5 A
Make VA/Break VA
Utilization Category
B300/R300
TB-11, -12
(Normal/Up-to-Speed)
AC-15/DC-13
Electromagnetic Relay
No. of Contacts
Type of Contact
Current
AC/DC
5A
Make VA/Break VA
9 Overvoltage category II when either control or auxiliary circuit is wired to a SELV or PELV circuit.
42
AC-15/DC-13
Electromagnetic Relay
Bulletin 150
Trip Class 15
Trip Class 20
200
180
160
140
Starts
120
100
80
60
40
20
150-C43
150-C60
150-C85
0 10 20 30 40 50 60 70 80 90
Current (amps)
200
180
160
140
Start/Hour
120
100
80
60
40
20
150-C108
150-F135
0
0
10
20
30
40
50
60
70
80
90
43
Bulletin 150
Open Type
Controller
Mounting
Hole Size
137 A
44.8 (1-49/64)
139.7 (5-1/2)
100 (4-21/64)
35 (1-3/8)
132 (5-13/64)
46.4 (1.81)
2 (1/16)
4.6 (0.18)
4385 A
72 (2.83)
206 (8.11)
130 (5.12)
55 (2.17)
198 (7.8)
102 (4.02)
2 (1/16)
5.3 (0.21)
108135 A
196.4 (7.74)
443.7 (17.47)
205.2 (8.08)
166.6 (6.56)
367 (14.45)
7.5 (0.295)
44
Controller
A Width
B Height
C Depth
137 A
224 (9)
305 (12)
152 (6)
none
4385 A
406 (16)
305 (12)
203 (8)
none
108135 A
762 (30)
610 (24)
305 (12)
none
Fan Requirements
Bulletin 150
Controller
Rating (A)
B Height
A Width
C Depth
Non-Combination Controller
3
305 (12)
305 (12)
152 (6)
305 (12)
305 (12)
152 (6)
16
305 (12)
305 (12)
152 (6)
25
305 (12)
305 (12)
152 (6)
30
305 (12)
305 (12)
152 (6)
37
305 (12)
305 (12)
152 (6)
43
356 (14)
406 (16)
203 (8)
60
356 (14)
406 (16)
203 (8)
85
356 (14)
406 (16)
203 (8)
108
762 (30)
610 (24)
305 (12)
135
762 (30)
610 (24)
305 (12)
203 (8)
30 A/J
356 (14)
406 (16)
30 A/J
356 (14)
406 (16)
203 (8)
16
30 A/J
356 (14)
406 (16)
203 (8)
25
30 A/J
356 (14)
406 (16)
203 (8)
30
60 A/J
356 (14)
406 (16)
203 (8)
37
60 A/J
356 (14)
406 (16)
203 (8)
43
60 A/J
356 (14)
406 (16)
203 (8)
60
100 A/J
610 (24)
406 (16)
254 (10)
859
100 A/J
610 (24)
406 (16)
254 (10)
857
100 A/J
762 (30)
610 (24)
305 (12)
108
200 A/J
965 (38)
762 (30)
356 (14)
135
200 A/J
965 (38)
762 (30)
356 (14)
15 A
356 (14)
406 (16)
203 (8)
15 A
356 (14)
406 (16)
203 (8)
16
20 A
356 (14)
406 (16)
203 (8)
25
30 A
356 (14)
406 (16)
203 (8)
30
40 A
356 (14)
406 (16)
203 (8)
37
50 A
356 (14)
406 (16)
203 (8)
43
80 A
610 (24)
406 (16)
254 (10)
60
100 A
610 (24)
406 (16)
254 (10)
85
125 A
610 (24)
406 (16)
254 (10)
108
965 (38)
762 (30)
356 (14)
135
965 (38)
762 (30)
356 (14)
45
Bulletin 150
Option
Cat. No.
Modification
Description
-1
Push Buttons
Selector Switch
Pilot Light
-3
-4R
Control Circuit Transformer Control Circuit Transformer (fused primary and secondary)
Protective Module
Auxiliary Contacts
Disconnect Auxiliary
46
-6P
385 A
385 A
43135 A
43135 A
43135 A
43135 A
-8L
-8M
-8B
-90
-900
-901
-98
-99
Bulletin 150
N.O.
N.C.
150-CA10
150-CA20
150-CA01
150-CA11
(Form C)
Description
Connection Diagram
Cat. No.
Pkg. Qty.
Fan
Field installed.
150-C4385/150-D74147
Description
480V Protective Module
Cat. No.
150-CF64
150-C337/150-D364
150-CF147
Connects 140M-C to
150-C325/150-D325
150-CC25
Connects 140M-D to
150-C325/150-D325
150-CD25
Connects 140M-F to
150-C337/150-D332
150-CF45
Connects 100-C0923 to
150-C319/150-D320
150-CI23
Connects 100-C3037 to
150-C337/150-D332
150-CI37
Pkg. Qty.
Cat. No.
150-C337NB or 150-D364NB
150-C84
150-C4385NB or 150-D74147NB
150-C84P
150-C108135NB
150-F84L
150-C337NC or 150-D364NC
150-C86
150-C4385NC or 150-D74147NC
150-C86P
150-C108135NC
150-F86L
150-C108135
150-TC1
Terminal Covers
IEC line or load terminal
covers for 108135 A
devices.
Dead front protection
Description
Marking Tag Sheet
10 sheets with 160 perforated paper labels each, 6 x 17
mm
To be used with a transparent cover
Transparent Cover
100 each
To be used with marking tag sheets
Pkg. Qty.
Cat. No.
150-C, 150-D
10
100-FMP
150-C, 150-D
100
100-FMC
150-C, 150-D
193-ER1
24
48
110
115
120
220
240
50 Hz
60 Hz
DC
Z24
Z48
Z01
Surcharge for special voltages up to 20 pcs. (no surcharge for quantities greater than 20 pcs.)
47
Bulletin 150
Table of Contents
Cat. No. Identification............ 49
Product Selection .................... 50
Typical Wiring Diagrams ....... 51
Specifications............................ 53
Approximate Dimensions ..... 56
Accessories (SMC-3 and
SMC-Delta)................................. 47
The controllers are available in 11 sizes: 3, 9, 16, 20, 25, 32, 51, 64, 74, 104, and 147 A.
They offer two voltage ranges: 200460V AC and 200575V AC. All voltage ranges
will operate at either 50 or 60 Hz.
y 1147 A Range
y Built-in Motor Overload Protection
y Built-in SCR Bypass
Standards Compliance/Approvals
y UL 508
y CSA C22.2 No. 14
y EN/IEC 60947-4-2
y cULus Listed (Open Type) (File No. E96956)
y CE Marked (Open Type) per EMC Directive and Low Voltage Directive
Mode of Operation
Current Limit Start
This starting mode is used when it is necessary to limit the maximum
starting current. It can be adjusted for 150%, 250%, 300%, or 350% of
full load amps. Start times are selectable from 2, 5, 10, 15, 20, 25, or 30 s.
(364 A, 215 s only)
Shorted SCR
Prior to every start, the unit will check all SCRs for shorts and unit
load connections to the motor. If there is a shorted SCR in the
SMC-Delta, the start will be aborted and a shorted SCR fault will be
indicated. This prevents damage from phase imbalance.
Over-temperature
The SMC-Delta monitors the SCR temperature by means of internal
thermistors. When the power poles maximum rated temperature is
reached, the microcomputer switches off the SMC, a TEMP fault is
indicated via LED, and the 97/98 fault contact closes.
Push to Test
The unit with control wiring can be tested for fault conditions by
using the Push to Test function. Hold down the Reset button for 5
seconds to activate the fault Aux (97, 98) and shut down the SMCDelta. To clear, either push the Reset button or cycle control power
to the device.
Phase Imbalance
1.
2.
3.
4.
5.
6.
7.
Overload
Overtemperature
Not Used
Phase Loss/Open Load
Phase Imbalance
Shorted SCR
Test
48
Bulletin 150
Open Type
150 D
a
32
a
Code
150
Bulletin Number
Description
Solid-State Controller
Code
D
Controller Type
Description
SMC-Delta
Code
3
9
16
20
25
32
51
64
74
104
147
Ampere Ratings
Description
3A
9A
16 A
20 A
25 A
32 A
51 A
64 A
74 A
104 A
147 A
Code
N
Enclosure Type
Description
Open
e
Code
B
C
f
Code
D
R
Control Voltage
Description
100240V AC
24V AC/DC
49
Bulletin 150
Rated Voltage
[V AC]
200/208
230
380/400/
415/460
500/575
100240V
AC, 50/60 Hz
Control
Current
Rating (A)
9
kW
Hp
Cat. No.
Cat. No.
13
0.5
150-D3NBD
150-D3NBR
39
0.752
150-D9NBD
150-D9NBR
5.316
1.53
150-D16NBD
150-D16NBR
6.720
25
150-D20NBD
150-D20NBR
9.227.7
37.5
150-D25NBD
150-D25NBR
10.632.9
310
150-D32NBD
150-D32NBR
17.351.9
515
150-D51NBD
150-D51NBR
21.364
7.520
150-D64NBD
150-D64NBR
24.774
7.520
150-D74NBD
150-D74NBR
34.7104
1530
150-D104NBD 150-D104NBR
49147
1540
150-D147NBD 150-D147NBR
13
0.55
0.5
150-D3NBD
39
2.2
0.752
150-D9NBD
150-D9NBR
5.316
1.55
150-D16NBD
150-D16NBR
150-D3NBR
6.720
5.5
25
150-D20NBD
150-D20NBR
9.227.7
5.5
37.5
150-D25NBD
150-D25NBR
10.632.9
7.5
510
150-D32NBD
150-D32NBR
17.351.9
15
7.515
150-D51NBD
150-D51NBR
21.364
18.5
7.520
150-D64NBD
150-D64NBR
24.774
22
7.525
150-D74NBD
150-D74NBR
34.7104
30
1540
150-D104NBD 150-D104NBR
150-D147NBD 150-D147NBR
49147
45
2050
13
1.1
0.51.5
150-D3NBD
39
1.55
150-D9NBD
150-D9NBR
5.316
7.5
510
150-D16NBD
150-D16NBR
150-D3NBR
6.720
7.5
510
150-D20NBD
150-D20NBR
9.227.7
11
7.515
150-D25NBD
150-D25NBR
10.632.9
15
7.520
150-D32NBD
150-D32NBR
17.351.9
22
1530
150-D51NBD
150-D51NBR
21.364
30
2040
150-D64NBD
150-D64NBR
24.774
37
1550
150-D74NBD
150-D74NBR
34.7104
55
2575
150-D104NBD 150-D104NBR
49147
75
40100
150-D147NBD 150-D147NBR
13
1.5
0.752
150-D3NCD
39
5.5
37.5
150-D9NCD
150-D9NCR
5.316
7.5
310
150-D16NCD
150-D16NCR
6.720
11
7.515
150-D20NCD
150-D20NCR
9.225
15
7.520
150-D25NCD
150-D25NCR
10.632
18.5
1030
150-D32NCD
150-D32NCR
1751
30
1540
150-D51NCD
150-D51NCR
21.364
37
2060
150-D64NCD
150-D64NCR
24.774
45
2060
150-D74NCD
150-D74NCR
34.7104
55
40100
150-D104NCD 150-D104NCR
49147
90
50150
150-D147NCD 150-D147NCR
9 Motor FLA must fall within the current range of the device.
50
24V AC/DC
Control
150-D3NCR
Bulletin 150
NEMA
Three-Wire Configuration
IEC
NEMA
51
Bulletin 150
NEMA
Reversing Configuration
Note: Minimum Off time equals 1.0 s.
IEC
52
NEMA
Bulletin 150
D3
D9
D16
D20
D25
D32
D51
D64
D74
D104
D147
16
20
25
32
51
64
74
104
147
Heat dissipation
Continuous
(W)
10
14
19
27
42
74
Line Power
terminals
Cable size:
Tightening
torque:
Load Power
terminals
Cable size:
Tightening
torque:
Control
terminals
Cable size:
Tightening
torque:
9A
16 A
20 A
1.74
5.2
9.3
11.6
13
39
5.316
6.720
25 A
32 A
51 A
14.5
17.4
29.6
64 A
74 A
104 A
147 A
36.5
42.8
60.1
85
21.364
24.774
34.7104
49147
250 A
250 A
400 A
400 A
125 A
125 A
225 A
250 A
250 A
250 A
300 A
400 A
F45
UL Class K5 Fuses
UL Listed Combination (600V)
UL Class K5 Fuses
UL Listed Combination (600V)
UL Class RK5 Fuses 9
UL Listed Combination (600V)
UL Class RK5 Fuses 9
UL Listed Combination (600V)
35 A
60 A
80 A
100 A
6A
20 A
35 A
45 A
50 A
200 A
70 A
110 A
35 A
60 A
80 A
100 A
125 A
125 A
200 A
C25
C25
F45
F45
F45
F45
Power Circuit
UL/cUL
IEC
200480V AC
200480V~ 400V~
500600V AC
500V~ 500V~
600V AC
500V~
Dielectric withstand
2200V AC
2500V~
200480V AC 1400V
200480V~ 1400V
500600V AC 1600V
500V~ 1600V
Repetitive peak
Operating frequency
50/60 Hz
50/60 Hz
164 A
Utilization
category
74104 A
AC-53b: 3.5-15:3585
AC-53b: 3.5-15:885
147 A
AC-53b: 3.5-15:1785
Number of poles
6 kV
1000 V/s
DV/DT protection
Overvoltage Category
III
III
Environmental
Operating temperature
Storage temperature
Altitude
Humidity
595% (non-condensing)
Pollution degree
Type of Protection
2
IP2X
9 Use 175% of motor FLA. These fuses are time delay or Class J.
7 Consult local codes for proper sizing of short circuit protection.
53
Bulletin 150
UL/cUL
IEC
100240V AC, 24V AC/DC
100240V~, 24V AC/DC
250V
250V~
4 kV
1500V AC
2000V~
III 9
50/60 Hz
50/60 Hz
85V AC, 19.2V DC/13.5V AC
195 mA @ 120V AC/140 mA @ 240V AC, 790mA @24V DC/650 mA @24V AC
200 mA @ 120V AC/100 mA @ 240V AC, 700 mA @24V AC/DC
30V AC, 17V DC/12V AC
<2 mA
195 mA @ 120V AC / 140 mA @ 240V AC, 790 mA @ 24V DC / 650 mA @ 24V AC
200 mA @ 120V AC/100 mA @ 240V AC, 700 mA @24V AC/DC
185 mA @ 120V AC/125 mA @ 240V AC, 695 mA @24V DC/ 570 mA @ 24V AC
Auxiliary Contact
UL/cUL
IEC
250V AC/30V DC
250V
1500V AC
50/60 Hz
D300
250V~/30V DC
250V~
4 kV
2000V~
III 9
50/60 Hz
AC15
Electromagnetic relay
1
Normally Open (N.O.)
AC/DC
0.6 A @ 120V~ and 0.3 A @ 240V~
1A
432/72
Standard Features
Start times
Selectable current limit
164 A
74147 A
Mechanical Design Specifications/Test Requirements
Operational
Resistance to vibration
Non-operational
Operational
Resistance to shock
Non-operational
Weight kg (lbs)
EMC
emission
levels
EMC
immunity
levels
Wiring Diagrams
UL/cUL
IEC
Class A
Radiated emissions
Class A
Electrostatic discharge
Radio frequency electromagnetic field
Fast transient
Surge transient
9 Overvoltage category II, when either control or auxiliary circuit is wired to a SELV or PELV circuit.
54
Bulletin 150
IEC
250V AC/30V DC
250V AC/30V DC
250V
250V AC
4 kV
Dielectric Withstand
1500V AC
2000V AC
Overvoltage Category
III 9
Operating Frequency
50/60 Hz
50/60 Hz
Utilization Category
C300/R150
No. of Contacts
Type of Contact
Current
AC/DC
2.5 A
Make VA/Break VA
Utilization Category
B300/R300
TB-11, -12
(Normal/Up-to-Speed)
AC-15/DC-13
Electromagnetic Relay
AC-15/DC-13
Electromagnetic Relay
No. of Contacts
Type of Contact
Current
AC/DC
5A
Make VA/Break VA
9 Overvoltage category II when either control or auxiliary circuit is wired to a SELV or PELV circuit.
55
Bulletin 150
Trip Class 15
Trip Class 20
180
160
Starts
140
120
100
80
60
40
20
0
0
30
60
90
Current (amps)
150-D74
150-D104
150-D147
56
120 150
Bulletin 150
Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. All dimensions are subject to
change.
Open Type
Mounting
Hole Size
Controller
164 A
44.8 (1-49/64)
139.7 (5-1/2)
100 (4-21/64)
35 (1-3/8)
132 (5-13/64)
46.4 (1.81)
2 (1/16)
4.6 (0.18)
74147 A
72 (2.83)
206 (8.11)
130 (5.12)
55 (2.17)
198 (7.8)
102 (4.02
2 (1/16)
5.3 (0.21)
Controller
164 A
74147 A
A Width
224 (9)
406 (16)
B Height
305 (12)
305 (12)
C Depth
152 (6)
203 (8)
Fan Requirements
none
none
57
Bulletin 150
58
modularity
functionality
size
www.rockwellautomation.com
Corporate Headquarters
Rockwell Automation, 777 East Wisconsin Avenue, Suite 1400, Milwaukee, WI, 53202-5302 USA, Tel: (1) 414.212.5200, Fax: (1) 414.212.5201
Headquarters for Allen-Bradley Products, Rockwell Software Products and Global Manufacturing Solutions
Americas: Rockwell Automation, 1201 South Second Street, Milwaukee, WI 53204-2496 USA, Tel: (1) 414.382.2000, Fax: (1) 414.382.4444
Europe/Middle East/Africa: Rockwell Automation SA/NV, Vorstlaan/Boulevard du Souverain 36, 1170 Brussels, Belgium, Tel: (32) 2 663 0600, Fax: (32) 2 663 0640
Asia Pacific: Rockwell Automation, 27/F Citicorp Centre, 18 Whitfield Road, Causeway Bay, Hong Kong, Tel: (852) 2887 4788, Fax: (852) 2508 1846
Headquarters for Dodge and Reliance Electric Products
Americas: Rockwell Automation, 6040 Ponders Court, Greenville, SC 29615-4617 USA, Tel: (1) 864.297.4800, Fax: (1) 864.281.2433
Europe/Middle East/Africa: Rockwell Automation, Brhlstrae 22, D-74834 Elztal-Dallau, Germany, Tel: (49) 6261 9410, Fax: (49) 6261 17741
Asia Pacific: Rockwell Automation, 55 Newton Road, #11-01/02 Revenue House, Singapore 307987, Tel: (65) 6356-9077, Fax: (65) 6356-9011
Publication 150-SG009A-EN-P May 2005
Supersedes 150-SG008C-EN-P June 2004 and 150-SG006D-EN-P December 2004
Copyright 2005 Rockwell Automation, Inc. All rights reserved. Printed in USA.