Вы находитесь на странице: 1из 14

DIMENSIONAMIENTO Y ANLISIS DE

ESCENARIOS DE UN AEROENFRIADOR
DE GAS NATURAL
CURSO: SIMULACIN Y DIMENSIONAMIENTO DE INTERCAMBIADORES DE
CALOR
CAPTULO 7

Ingeniero de Procesos - Luis Torres Melchor

12/11/2016

ASPEN EXCHANGER DESIGN & RATING FAMILY

Ingeniero de Procesos - Luis Torres Melchor

12/11/2016

ASPEN SHELL & TUBE EXCHANGER


OVERVIEW OF AIR-COOLED EXCHANGERS

Ingeniero de Procesos - Luis Torres Melchor

12/11/2016

ASPEN SHELL & TUBE EXCHANGER


OVERVIEW OF AIR-COOLED EXCHANGERS

Ingeniero de Procesos - Luis Torres Melchor

12/11/2016

ASPEN SHELL & TUBE EXCHANGER


OVERVIEW OF AIR-COOLED EXCHANGERS

Ingeniero de Procesos - Luis Torres Melchor

12/11/2016

ASPEN SHELL & TUBE EXCHANGER


OVERVIEW OF AIR-COOLED EXCHANGERS
USED TO COOL AND/OR CONDENSE PROCESS
STREAMS WITH AMBIENT AIR
USUALLY EMPLOY FINNED TUBES
FREQUENTLY BUILT IN UNITS
ALLOWS FOR MULTIPLE SERVICES PER BAY
TYPICAL APPLICATIONS:
COLUMN OVERHEAD CONDENSERS
REFRIGERATION-CYCLE CONDENSERS
INTERSTAGE COOLERS IN COMPRESSOR CIRCUITS
Ingeniero de Procesos - Luis Torres Melchor

12/11/2016

ASPEN SHELL & TUBE EXCHANGER


ASPEN AIR-COOLED EXCHANGER
DESIGN, SIMULATION, RATING CALCULATION
MODES
UP TO 50 PASSES IN SIMPLE AND COMPLEX
ARRENGEMENTS
TUBE SIDE CONDENSING OR BOILING HEAT
RECOVERY, DEHUMIDIFICATION, AIR COOLED
AND OTHER TUBULAR CROSS-FLOW
EXCHANGERS
MULTIPLE TUBE HIGH FIN AND HEADER TYPES
AUTOMATED HANDLING OF CONDENSATION
WITH INMISCIBLE FLUIDS
WEIGHT AND BUDGET ESTIMATES
Ingeniero de Procesos - Luis Torres Melchor

12/11/2016

ASPEN SHELL & TUBE EXCHANGER


AIR-COOLED EXCHANGER EXCHANGER
CONFIGURATION
FRAME TYPE
STANDARD
A OR V FRAME

FANS
FORCED DRAUGHT
INDUCED DRAUGHT

NO FANS (NATURAL CONVECTION)


BUNDLES

TUBE LAYOUT
TUBES
FIN TYPE
NOZZLES & HEADERS

Ingeniero de Procesos - Luis Torres Melchor

12/11/2016

ASPEN SHELL & TUBE EXCHANGER


CASE 5: DESIGN AND SCENARIOS ANALYSIS ON A PROPANE AIR-COOLED
OBJECTIVE
THE PURPOSE IS TO RATE AN AIR COOLER FROM A REFRIGERATION CYCLE USING ASPEN AIR COOLED
EXCHANGER
A FULL API SHEET IS PROVIDED
WE ARE GOING TO USE THE IMPORT FEATURE TO EXTRACT HEAT CURVES (PROCESS DATA AND PROPERTIES)
FOR EXCHANGER AC-100 FROM ASPEN HYSYS

TASKS
START ASPEN EDR & IMPORT PROCESS DATA AND PROPERTIES FROM A HYSYS CASE
ENTER GEOMETRY INFORMATION FROM THE API SHEET INTO ASPEN AIRE COOLED EXCHANGER
REVIEW ASPEN AIR COOLED EXCHANGER RESULTS
Ingeniero de Procesos - Luis Torres Melchor

12/11/2016

ASPEN SHELL & TUBE EXCHANGER


CASE 5: DESIGN AND SCENARIOS ANALYSIS ON A PROPANE
AIR-COOLED
IMPORT FROM ASPEN HYSYS: AC-100 (SELECT THE
APPROPRIATELY FILE)
WE WANT TO IMPORT PROPERTIES FOR THE TUBE SIDE

Ingeniero de Procesos - Luis Torres Melchor

12/11/2016

10

ASPEN SHELL & TUBE EXCHANGER


CASE 5: DESIGN AND SCENARIOS ANALYSIS ON A PROPANE AIR-COOLED
UNITS OF MEASURE: US/SI
CALCULATION MODE: RATING OR SIMULATION
ENTER OUTSIDE STREAM ADDITIONAL INFORMATION

ENTER API INFORMATION


Ingeniero de Procesos - Luis Torres Melchor

12/11/2016

11

ASPEN SHELL & TUBE EXCHANGER


CASE 5: DESIGN AND SCENARIOS ANALYSIS ON A PROPANE AIR-COOLED
WE ARE ALSO GIVE SOME ADDITIONAL INFORMATION ABOUT THE EQUIPMENT UNITS OF MEASURE:
US/SI

Ingeniero de Procesos - Luis Torres Melchor

12/11/2016

12

ASPEN SHELL & TUBE EXCHANGER


CASE 5: DESIGN AND SCENARIOS ANALYSIS ON A PROPANE AIR-COOLED
RUN CONTROL
CLICK RUN
SAVE CASE: 6_PROPANE AIRCOOLED

Ingeniero de Procesos - Luis Torres Melchor

12/11/2016

13

ASPEN SHELL & TUBE EXCHANGER


CASE 5: DESIGN AND SCENARIOS ANALYSIS ON A
PROPANE AIR-COOLED
REVIEW RESULT SUMMARY
USE SCENARIO ANALYSIS CHANGING INLET AIR
TEMPERATURA FROM ASPEN HYSYS (SIMULATION
MODE)

NOTE: IF YOUR PC HAVE MS OFFICE IN 32 BITS (LIKE


ASPENONE OR VICEVERSA IN 64 BITS BOTH) YOU CAN
USE ASPEN SIMULATION WORKBOOK TO DO
DIFFERENT SCENARIO ANALYSIS
Ingeniero de Procesos - Luis Torres Melchor

12/11/2016

14