Valve systems Standardized valve systems
Electrically operated
12
16
20
24
Pneumatically operated
28
Accessories
Single valves, electrically operated
on
line
on
line
Soft-start valves
Soft-start valve
Qn=3300 l/min Pilot valve width: 15 mm Manual override: without detent
34
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
3
Valve systems Standardized valve systems
Soft-start valve
Qn=3300 l/min Pilot valve width: 22 mm Manual override: with detent
Soft-start valve
Qn=3300 l/min Pilot valve width: 30 mm Manual override: without detent, with
detent, without
40
Pilot valve
581, Modular system Pilot valve width: 22 mm Manual override: with detent
41
Pilot valve
581, Modular system Pilot valve width: 30 mm
42
3/2-directional valve
Manual override: without detent
44
36
38
Pilot valves
46
47
49
51
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
4
Valve systems Standardized valve systems
52
54
Pilot valve
581, Modular system Pilot valve width: 15 mm Manual override: without detent
56
Electro module
Plug, M8, 3-pin 581, Modular system
58
59
Blanking plug
for581
60
61
61
62
63
63
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
5
Valve systems Standardized valve systems
64
65
65
66
Single subbase
67
68
70
71
72
74
76
78
80
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
6
Valve systems Standardized valve systems
82
85
89
91
93
Blanking plate
standard: ISO 5599-1 Frame size: ISO 1
95
Blanking plate
standard: ISO 5599-1 Frame size: ISO 1
96
Throttle plate
standard: ISO 5599-1 Frame size: ISO 1
97
98
Accessories
Accessories, type G
Transition plate
standard: ISO 5599-1 Frame size: ISO 1 - ISO 2 type G Can be assembled into
blocks Reversed pressure supply permissible
101
Supply plate
standard: ISO 5599-1 Frame size: ISO 1 type F Reversed pressure supply
permissible
102
Transition plate
standard: ISO 5599-1 Frame size: ISO 1 -> ISO 2 type F Can be assembled into
blocks Reversed pressure supply permissible
103
Accessories, type F
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
7
Valve systems Standardized valve systems
Transition plate
standard: ISO 5599-1 Frame size: ISO 1 -> ISO 3 - ISO2 -> ISO 3 type F Can
be assembled into blocks Reversed pressure supply permissible
104
106
Angle subplate
standard: ISO 5599-1 Frame size: ISO 1 type F Compressed air connection
output: G 1/4
107
Supply plate
standard: ISO 5599-1 Frame size: ISO 1 type F Reversed pressure supply
permissible
109
Blanking piece
type F Frame size:ISO 1
110
110
111
Accessories, type H
Supply plate
standard: ISO 5599-1 Frame size: ISO 1 type H Can be assembled into blocks
Plate principle
113
Separator set
type K Frame size:ISO 1
114
112
Accessories, type K
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
8
Valve systems Standardized valve systems
Qn=1100 l/min Pilot valve width: 15 mm Compressed air connection output: Base plate ISO 5599-1
Manual override: without detent
Standards
ISO 5599-1
Version
Blocking principle
-10C / +50C
Medium
Compressed air
50 m
0 mg/m - 5 mg/m
Protection class
with connection
IP65
DC operating voltage
24 V
Voltage tolerance DC
-10% / +10%
P581_168
Materials:
Plug box
Seal
An example configuration is illustrated. The delivered product may thus deviate from the illustration.
Technical Remarks
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!
The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C.
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS, see chapter Technical information.
Configurable product
This product is configurable. Please use our Internet configurator at http://www.aventics.com or contact the
nearest AVENTICS sales office.
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
9
Valve systems Standardized valve systems
Qn=1100 l/min Pilot valve width: 15 mm Compressed air connection output: Base plate ISO 5599-1
Manual override: without detent
D581_231_15
* n = number of subbases.
** Alternative port openings, closed with plugs.
*** Only on subbases with separate intake.
**** Subbase 5801680000 can also be connected to port 3 and 5.
An example configuration is illustrated. The delivered product may thus deviate from the illustration.
G 1/8
G 1/4
G 1/4
G 1/8
22
28.5
9.5
29.5
14.5
100
25
27
43
P (=M+Q)
G 1/4
G 3/8
G 3/8
G 1/8
27
40
12.5
26.5
20
122
30
34
43
49
G 1/4
G 1/4
22
28.5
9.5
29.5
14.5
100
25
27
43
41
G 3/8
G 3/8
27
40
12.5
26.5
20
122
30
34
43
49
G 1/8
14
R (=Q/2+MZ)
27.5
60
72
5.4
AA
T1
U1
G 1/4
15
34
65
94
6.4
10
92
93
14
27.5
60
72
5.4
85
93
15
34
65
94
6.4
92
93
85
93
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
41
10
Valve systems Standardized valve systems
Qn=1100 l/min Pilot valve width: 15 mm Compressed air connection output: Base plate ISO 5599-1
Manual override: without detent
D581_232_15
* n = Number of subbases
An example configuration is illustrated. The delivered product may thus deviate from the illustration.
G 1/4
G 1/4
G 3/8
21.5
G 3/8
24.5
G 1/8
86
28
13
28
H1
29
11
H2
H3
20
39.5
T1
U1
107
22
110
46
22
43
71
93
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
11
Valve systems Standardized valve systems
Qn=1100 l/min Pilot valve width: 15 mm Compressed air connection output: Base plate ISO 5599-1
Manual override: without detent
D581_233_15
* n = Number of subbases
An example configuration is illustrated. The delivered product may thus deviate from the illustration.
G 1/4
G 1/4
G 3/8
43
B1
G 1/4
5.5
11
T1
U1
106
96
71
32
22
92
24
17
12
93
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
12
36
22
12
Valve systems Standardized valve systems
Qn=1100 l/min Pilot valve width: 15 mm Compressed air connection output: Base plate ISO 55991 Electr. connection: Single wire connection, electronic connection module and multiple cable Manual
override: without detent
P581_136
Standards
ISO 5599-1
Version
Blocking principle
-10C / +50C
Medium
Compressed air
50 m
0 mg/m - 5 mg/m
Protection class
with connection
IP67
20
DC operating voltage
24 V
Voltage tolerance DC
-10% / +10%
cable connection
10 m
Materials:
Plug box
Seal
An example configuration is illustrated. The delivered product may thus deviate from the illustration.
Technical Remarks
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!
The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C.
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS, see chapter Technical information.
Configurable product
This product is configurable. Please use our Internet configurator at http://www.aventics.com or contact the
nearest AVENTICS sales office.
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
13
Valve systems Standardized valve systems
Qn=1100 l/min Pilot valve width: 15 mm Compressed air connection output: Base plate ISO 55991 Electr. connection: Single wire connection, electronic connection module and multiple cable Manual
override: without detent
Dimensions,all ports on bottom
D581_231_15
* n = number of subbases.
** Alternative port openings, closed with plugs.
*** Only on subbases with separate intake.
**** Subbase 5801680000 can also be connected to port 3 and 5.
An example configuration is illustrated. The delivered product may thus deviate from the illustration.
G 1/8
G 1/4
G 1/4
G 1/8
22
28.5
9.5
29.5
14.5
100
25
27
43
P (=M+Q)
G 1/4
G 3/8
G 3/8
G 1/8
27
40
12.5
26.5
20
122
30
34
43
49
G 1/4
G 1/4
22
28.5
9.5
29.5
14.5
100
25
27
43
41
G 3/8
G 3/8
27
40
12.5
26.5
20
122
30
34
43
49
G 1/8
14
R (=Q/2+MZ)
27.5
60
72
5.4
AA
T1
U1
G 1/4
15
34
65
94
6.4
10
92
93
14
27.5
60
72
5.4
85
93
15
34
65
94
6.4
92
93
85
93
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
41
14
Valve systems Standardized valve systems
Qn=1100 l/min Pilot valve width: 15 mm Compressed air connection output: Base plate ISO 55991 Electr. connection: Single wire connection, electronic connection module and multiple cable Manual
override: without detent
Dimensions,ports 2 and 4 on bottom,Ports 12 and 14 on side
D581_232_15
* n = Number of subbases
An example configuration is illustrated. The delivered product may thus deviate from the illustration.
G 1/4
G 1/4
G 3/8
21.5
G 3/8
24.5
G 1/8
86
28
13
28
H1
29
11
H2
H3
20
39.5
T1
U1
107
22
110
46
22
43
71
93
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
15
Valve systems Standardized valve systems
Qn=1100 l/min Pilot valve width: 15 mm Compressed air connection output: Base plate ISO 55991 Electr. connection: Single wire connection, electronic connection module and multiple cable Manual
override: without detent
Dimensions,ports 2 and 4 on side,ports 12 and 14 on bottom
D581_233_15
* n = Number of subbases
An example configuration is illustrated. The delivered product may thus deviate from the illustration.
G 1/4
G 1/4
G 3/8
43
B1
G 1/4
5.5
11
T1
U1
106
96
71
32
22
92
24
17
12
93
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
12
36
22
16
Valve systems Standardized valve systems
Qn=1100 l/min Pilot valve width: 22 mm Compressed air connection output: Base plate ISO 5599-1
Electr. connection: Single wire connection, Electrical connector without standard (form B industry) Manual
override: with detent
P581_137
Standards
ISO 5599-1
Version
Blocking principle
-15C / +50C
Medium
Compressed air
50 m
0 mg/m - 5 mg/m
Protection class
with connection
IP65
DC operating voltage
24 V
Voltage tolerance DC
-10% / +10%
Operational voltage AC at 50 Hz
230 V, 110 V, 24 V
Voltage tolerance AC 50 Hz
-10% / +10%
Materials:
Plug box
Seal
An example configuration is illustrated. The delivered product may thus deviate from the illustration.
Technical Remarks
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!
The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C.
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS, see chapter Technical information.
Configurable product
This product is configurable. Please use our Internet configurator at http://www.aventics.com or contact the
nearest AVENTICS sales office.
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
17
Valve systems Standardized valve systems
Qn=1100 l/min Pilot valve width: 22 mm Compressed air connection output: Base plate ISO 5599-1
Electr. connection: Single wire connection, Electrical connector without standard (form B industry) Manual
override: with detent
Dimensions,all ports on bottom
D581_231_22
* n = number of subbases.
** Alternative port openings, closed with plugs.
*** Only on subbases with separate intake.
**** Subbase 5801680000 can also be connected to port 3 and 5.
An example configuration is illustrated. The delivered product may thus deviate from the illustration.
G 1/8
G 1/4
G 1/4
G 1/8
22
28.5
9.5
29.5
14.5
100
25
27
43
P (=M+Q)
G 1/4
G 3/8
G 3/8
G 1/8
27
40
12.5
26.5
20
122
30
34
43
49
G 1/4
G 1/4
22
28.5
9.5
29.5
14.5
100
25
27
43
41
G 3/8
G 3/8
27
40
12.5
26.5
20
122
30
34
43
49
G 1/8
14
R (=Q/2+MZ)
27.5
60
72
5.4
AA
113
T2
U2
G 1/4
15
34
65
94
6.4
10
119
70
14
27.5
60
72
5.4
113
70
15
34
65
94
6.4
119
70
70
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
41
18
Valve systems Standardized valve systems
Qn=1100 l/min Pilot valve width: 22 mm Compressed air connection output: Base plate ISO 5599-1
Electr. connection: Single wire connection, Electrical connector without standard (form B industry) Manual
override: with detent
Dimensions,ports 2 and 4 on bottom,Ports 12 and 14 on side
D581_232_22
* n = Number of subbases
An example configuration is illustrated. The delivered product may thus deviate from the illustration.
G 1/4
G 1/4
G 3/8
21.5
G 3/8
24.5
G 1/8
81
28
13
28
H1
29
11
H2
H3
20
39.5
T2
U2
134
22
110
46
22
43
71
68
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
19
Valve systems Standardized valve systems
Qn=1100 l/min Pilot valve width: 22 mm Compressed air connection output: Base plate ISO 5599-1
Electr. connection: Single wire connection, Electrical connector without standard (form B industry) Manual
override: with detent
Dimensions,ports 2 and 4 on side,ports 12 and 14 on bottom
D581_233_22
* n = Number of subbases
An example configuration is illustrated. The delivered product may thus deviate from the illustration.
G 1/4
G 1/4
G 3/8
43
B1
G 1/4
106
5.5
11
T2
U2
124
71
32
22
92
24
17
12
70
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
12
36
22
20
Valve systems Standardized valve systems
Qn=1100 l/min Pilot valve width: 30 mm CNOMO Compressed air connection output: Base plate ISO 55991 Manual override: with detent
P581_138
Standards
ISO 5599-1
Version
Blocking principle
-15C / +50C
Medium
Compressed air
50 m
0 mg/m - 5 mg/m
Protection class
with connection
IP65
DC operating voltage
24 V
Voltage tolerance DC
-10% / +10%
Operational voltage AC at 50 Hz
230 V
Voltage tolerance AC 50 Hz
-10% / +10%
Materials:
Plug box
Seal
An example configuration is illustrated. The delivered product may thus deviate from the illustration.
Technical Remarks
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!
The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C.
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS, see chapter Technical information.
Configurable product
This product is configurable. Please use our Internet configurator at http://www.aventics.com or contact the
nearest AVENTICS sales office.
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
21
Valve systems Standardized valve systems
Qn=1100 l/min Pilot valve width: 30 mm CNOMO Compressed air connection output: Base plate ISO 55991 Manual override: with detent
D581_231_30
* n = number of subbases.
** Alternative port openings, closed with plugs.
*** Only on subbases with separate intake.
**** Subbase 5801680000 can also be connected to port 3 and 5.
An example configuration is illustrated. The delivered product may thus deviate from the illustration.
G 1/8
G 1/4
G 1/4
G 1/8
22
28.5
9.5
29.5
14.5
100
25
27
43
P (=M+Q)
G 1/4
G 3/8
G 3/8
G 1/8
27
40
12.5
26.5
20
122
30
34
43
49
G 1/4
G 1/4
22
28.5
9.5
29.5
14.5
100
25
27
43
41
G 3/8
G 3/8
27
40
12.5
26.5
20
122
30
34
43
49
5.4
AA
15
34
64
94
6.4
10
101
174
14
27.5
60
72
5.4
100
174
15
34
64
94
6.4
101
174
6
8
T3
72
G 1/4
60
14
27.5
G 1/8
R (=Q/2+MZ)
100
U3
174
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
41
22
Valve systems Standardized valve systems
Qn=1100 l/min Pilot valve width: 30 mm CNOMO Compressed air connection output: Base plate ISO 55991 Manual override: with detent
D581_232_30
* n = Number of subbases
An example configuration is illustrated. The delivered product may thus deviate from the illustration.
G 1/4
G 1/4
G 3/8
21.5
G 3/8
24.5
G 1/8
81
28
13
28
H1
29
11
H2
20
T3
121
H3
39.5
22
110
46
22
43
71
U3
174
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
23
Valve systems Standardized valve systems
Qn=1100 l/min Pilot valve width: 30 mm CNOMO Compressed air connection output: Base plate ISO 55991 Manual override: with detent
D581_233_30
* n = Number of subbases
An example configuration is illustrated. The delivered product may thus deviate from the illustration.
G 1/4
G 1/4
G 3/8
43
B1
G 1/4
106
5.5
T3
111
11
71
32
22
92
24
17
12
U3
174
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
12
36
22
24
Valve systems Standardized valve systems
Qn=1100 l/min Pilot valve width: 30 mm CNOMO Compressed air connection output: Base plate ISO 55991 Manual override: without detent, without
P581_138
Standards
ISO 5599-1
Version
Blocking principle
-15C / +50C
Medium
Compressed air
50 m
0 mg/m - 5 mg/m
Protection class
with connection
IP65
DC operating voltage
24 V
Voltage tolerance DC
-10% / +10%
Operational voltage AC at 50 Hz
230 V, 42 V
Voltage tolerance AC 50 Hz
-10% / +10%
Materials:
Plug box
Seal
An example configuration is illustrated. The delivered product may thus deviate from the illustration.
Technical Remarks
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!
The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C.
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS, see chapter Technical information.
Configurable product
This product is configurable. Please use our Internet configurator at http://www.aventics.com or contact the
nearest AVENTICS sales office.
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
25
Valve systems Standardized valve systems
Qn=1100 l/min Pilot valve width: 30 mm CNOMO Compressed air connection output: Base plate ISO 55991 Manual override: without detent, without
D581_231_30
* n = number of subbases.
** Alternative port openings, closed with plugs.
*** Only on subbases with separate intake.
**** Subbase 5801680000 can also be connected to port 3 and 5.
An example configuration is illustrated. The delivered product may thus deviate from the illustration.
G 1/8
G 1/4
G 1/4
G 1/8
22
28.5
9.5
29.5
14.5
100
25
27
43
P (=M+Q)
G 1/4
G 3/8
G 3/8
G 1/8
27
40
12.5
26.5
20
122
30
34
43
49
G 1/4
G 1/4
22
28.5
9.5
29.5
14.5
100
25
27
43
41
G 3/8
G 3/8
27
40
12.5
26.5
20
122
30
34
43
49
5.4
AA
15
34
64
94
6.4
10
101
174
14
27.5
60
72
5.4
100
174
15
34
64
94
6.4
101
174
6
8
T3
72
G 1/4
60
14
27.5
G 1/8
R (=Q/2+MZ)
100
U3
174
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
41
26
Valve systems Standardized valve systems
Qn=1100 l/min Pilot valve width: 30 mm CNOMO Compressed air connection output: Base plate ISO 55991 Manual override: without detent, without
D581_232_30
* n = Number of subbases
An example configuration is illustrated. The delivered product may thus deviate from the illustration.
G 1/4
G 1/4
G 3/8
21.5
G 3/8
24.5
G 1/8
81
28
13
28
H1
29
11
H2
20
T3
121
H3
39.5
22
110
46
22
43
71
U3
174
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
27
Valve systems Standardized valve systems
Qn=1100 l/min Pilot valve width: 30 mm CNOMO Compressed air connection output: Base plate ISO 55991 Manual override: without detent, without
D581_233_30
* n = Number of subbases
An example configuration is illustrated. The delivered product may thus deviate from the illustration.
G 1/4
G 1/4
G 3/8
43
B1
G 1/4
106
5.5
T3
111
11
71
32
22
92
24
17
12
U3
174
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
12
36
22
28
Valve systems Standardized valve systems
Qn=1100 l/min Compressed air connection output: Base plate ISO 5599-1
Standards
ISO 5599-1
Version
pneumatically controlled
Blocking principle
-20C / +70C
Medium
Compressed air
50 m
0 mg/m - 5 mg/m
Materials:
P581_134
Plug box
Seal
An example configuration is illustrated. The delivered product may thus deviate from the illustration.
Technical Remarks
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!
The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C.
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS, see chapter Technical information.
Configurable product
This product is configurable. Please use our Internet configurator at http://www.aventics.com or contact the
nearest AVENTICS sales office.
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
29
Valve systems Standardized valve systems
Qn=1100 l/min Compressed air connection output: Base plate ISO 5599-1
D581_231_pn
* n = number of subbases.
** Alternative port openings, closed with plugs.
*** Only on subbases with separate intake.
**** Subbase 5801680000 can also be connected to port 3 and 5.
An example configuration is illustrated. The delivered product may thus deviate from the illustration.
G 1/8
G 1/4
G 1/4
G 1/8
22
28.5
9.5
29.5
14.5
100
25
27
43
P (=M+Q)
G 1/4
G 3/8
G 3/8
G 1/8
27
40
12.5
26.5
20
122
30
34
43
49
G 1/4
G 1/4
22
28.5
9.5
29.5
14.5
100
25
27
43
41
G 3/8
G 3/8
27
40
12.5
26.5
20
122
30
34
43
49
G 1/8
14
R (=Q/2+MZ)
27.5
60
72
5.4
AA
U2
G 1/4
15
34
65
94
6.4
10
70
14
27.5
60
72
5.4
70
15
34
65
94
6.4
70
70
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
41
30
Valve systems Standardized valve systems
Qn=1100 l/min Compressed air connection output: Base plate ISO 5599-1
D581_232_pn
* n = Number of subbases
An example configuration is illustrated. The delivered product may thus deviate from the illustration.
G 1/4
G 1/4
G 3/8
21.5
G 3/8
24.5
G 1/8
81
28
13
28
H1
H2
U2
29
11
20
H3
39.5
22
110
46
22
43
71
70
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
31
Valve systems Standardized valve systems
Qn=1100 l/min Compressed air connection output: Base plate ISO 5599-1
D581_233_pn
* n = Number of subbases
An example configuration is illustrated. The delivered product may thus deviate from the illustration.
G 1/4
G 1/4
G 3/8
43
B1
G 1/4
5.5
U2
106
11
71
32
22
92
24
17
12
70
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
12
36
22
32
Valve systems Standardized valve systems
33
Valve systems Standardized valve systems
Series 581
Accessories
34
Valve systems Standardized valve systems
Soft-start valve
Spool valve
3 bar / 10 bar
-15C / +50C
-15C / +50C
Medium
Compressed air
5 m
0 mg/m - 1 mg/m
Nominal flow Qn
3300 l/min
IP65
Duty cycle
100 %
60 ms
00130324
Weight
0.39 kg
Materials:
Housing
Aluminum
Seals
Technical Remarks
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!
The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C.
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS, see chapter Technical information.
DC
Operational
voltage
AC 50 Hz AC 60 Hz
DC
AC 50 Hz
Voltage
tolerance
AC 60 Hz
Power
consumption
DC
W
24 V
-10% / +10%
10
24 V
-10% / +10%
110 V
-10% / +10%
10
230 V
-10% / +10%
10
MO
Operating voltage
DC
AC 50
Hz
AC 60
Hz
24 V
24 V
Power
consumption
DC
Holding
power
Holding
power
Switch-on
power
Switch-on
power
AC 50 Hz
AC 60 Hz
AC 50 Hz
AC 60 Hz
[W]
[VA]
[VA]
[VA]
[VA]
5835901200
5835900100
10
Part No.
24 V
5835901100
24 V
5835902100
110 V
10
5835901300
230 V
10
5835901400
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
35
Valve systems Standardized valve systems
Part No.
Flow conductance
Note
C
[l/(s*bar)]
5835901200
1)
5835900100
1)
5835901100
5835902100
4)
11.3
2); 3)
5835901300
4)
5835901400
4)
MO = Manual override
1) with encapsulated cable
2) electrical connector form C, ISO 15217
3) pin spacing 8 mm
4) pin spacing 9.4 mm
Dimensions
D583_018
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
36
Valve systems Standardized valve systems
Soft-start valve
00130322
Version
Spool valve
3 bar / 10 bar
-15C / +50C
-15C / +50C
Medium
Compressed air
5 m
0 mg/m - 1 mg/m
Nominal flow Qn
3300 l/min
IP65
Duty cycle
100 %
60 ms
Weight
0.39 kg
Materials:
Housing
Aluminum
Seals
Technical Remarks
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!
The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C.
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS, see chapter Technical information.
DC
Operational
voltage
AC 50 Hz AC 60 Hz
DC
AC 50 Hz
Voltage
tolerance
AC 60 Hz
Power
consumption
DC
W
-
24 V
-10% / +10%
10
24 V
-10% / +10%
24 V
-10% / +10%
110 V
-10% / +10%
10
230 V
-10% / +10%
10
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
37
Valve systems Standardized valve systems
MO
Operating voltage
Power
consumption
DC
Holding
power
Holding
power
Switch-on
power
Switch-on
power
AC 50 Hz
AC 60 Hz
AC 50 Hz
AC 60 Hz
[VA]
Part No.
DC
AC 50
Hz
AC 60
Hz
[W]
[VA]
[VA]
[VA]
24 V
10
5832111200
24 V
10
5832115200
24 V
5832151100
24 V
5832155100
24 V
5832111100
24 V
5832115100
110 V
10
5832111300
110 V
10
5832115300
230 V
10
5832111400
230 V
10
5832115400
5832111000
Part No.
Flow conductance
C
[l/(s*bar)]
5832111200
5832115000
Note
2)
5832115200
1)
5832151100
2); 3)
5832155100
1); 3)
5832111100
5832115100
11.3
2)
1)
5832111300
2)
5832115300
1)
5832111400
2)
5832115400
1)
5832111000
2)
5832115000
11.3
MO = Manual override
1) Pilot valve on side
2) Pilot valve on top
3) Low power consumption
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
1)
38
Valve systems Standardized valve systems
Dimensions
D583_004
Soft-start valve
Qn=3300 l/min Pilot valve width: 30 mm Manual override: without detent, with detent, without
Version
Spool valve
3 bar / 10 bar
-15C / +50C
-15C / +50C
Medium
Compressed air
5 m
0 mg/m - 1 mg/m
Nominal flow Qn
3300 l/min
IP65
Duty cycle
100 %
60 ms
00130323
Weight
0.39 kg
Materials:
Housing
Aluminum
Seals
Technical Remarks
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!
The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C.
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS, see chapter Technical information.
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
39
Valve systems Standardized valve systems
Operational
voltage
AC 50 Hz
DC
24 V
-10% / +10%
230 V
24 V
-10% / +10%
DC
MO
Operating voltage
DC
AC 50 Hz
24 V
Voltage
tolerance
AC 50 Hz
Power
consumption
DC
W
Switch-on
power
AC 50 Hz
VA
Holding
power
AC 50 Hz
VA
-10% / +10%
10
Note
Part No.
6.7
Power
consumption
Holding
power
Switch-on
power
Flow conductance
DC
[W]
AC 50 Hz
[VA]
AC 50 Hz
[VA]
C
[l/(s*bar)]
6.7
230 V
10
24 V
230 V
10
24 V
6.7
230 V
5832171540
11.3
11.3
5832171440
1)
5832171650
5832171450
5832171530
11.3
10
MO = Manual override
1) Low power consumption
Dimensions
D583_019
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
5832171430
40
Valve systems Standardized valve systems
-20C / +70C
-20C / +70C
Medium
Compressed air
-1 bar / 16 bar
Exhaust (3,5)
uncollected exhaust
Ports separated
Materials:
Base plate
P583_007
Technical Remarks
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!
The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C.
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS, see chapter Technical information.
Input
[1]
G 1/2
Output
[2 / 4]
G 1/2
G 1/8
Weight
Part No.
[kg]
0.34
5834710000
Dimensions
D583_008
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
41
Valve systems Standardized valve systems
Pilot valve
581, Modular system Pilot valve width: 22 mm Manual override: with detent
Working pressure min./max.
0 bar / 10 bar
-15C / +50C
Medium
Compressed air
IP65
Duty cycle
100 %
Weight
P581_178
Technical Remarks
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!
The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C.
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS, see chapter Technical information.
DC
AC 50 Hz
Operational
voltage
AC 60 Hz
24 V
230 V
110 V
24 V
Operating voltage
DC
24 V
AC 50 Hz
AC 60 Hz
230 V
110 V
Power
consumption
DC
[W]
Power
consumption
DC
W
5
Weight
[kg]
Note
Part No.
0.031
0493818805
0.03
1)
0493818902
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
42
Valve systems Standardized valve systems
R16
14
22
3,
3
Dimensions
14
2,7
22
14
50
2,7
4,5
00132663
Pilot valve
-10C / +50C
Medium
Compressed air
IP65
Duty cycle
100 %
Weight
P581_160
Technical Remarks
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!
The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C.
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS, see chapter Technical information.
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
43
Valve systems Standardized valve systems
DC
Operational
voltage
AC 50 Hz
DC
Voltage
tolerance
AC 50 Hz
Power
consumption
DC
W
Switch-on
power
AC 50 Hz
VA
Holding
power
AC 50 Hz
VA
230 V
-20% / +10%
24 V
-10% / +10%
24 V
-10% / +10%
6.7
12 V
-10% / +10%
48 V
-10% / +10%
110 V
-10% / +10%
220 V
-10% / +10%
24 V
-20% / +10%
10
48 V
-20% / +10%
10
110 V
-20% / +10%
10
Note
Part No.
1)
5428110080
1); 2)
5420890020
MO
Operating voltage
Power
consumption
Holding
power
DC AC 50 Hz
DC
[W]
AC 50 Hz
[VA]
230 V
Switch-on Working
power pressure
min./
max.
AC 50 Hz
[VA]
[bar]
24 V
6.7
230 V
10
0 / 10
0.17
0.206
0 / 16
[kg]
10
24 V
10
0.162
5420850020
1)
5428150080
12 V
1); 2)
5420890010
48 V
1); 2)
5420890030
110 V
1); 2)
5420890070
220 V
1); 2)
5420890080
24 V
10
1)
5428110020
48 V
10
1)
5428110040
110 V
10
1)
5428110070
0 / 10
0.17
MO = Manual override
1) pilot valve 30x22 mm with CNOMO porting configuration
2)Low power consumption
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
44
Valve systems Standardized valve systems
Dimensions
35,5
29,9
M5
5
21
. . . 022
...
10
PRESS
30
7,5
max.
PR1
22
100%ED
M4
87mA
16bar
24V
29,5
56,5
...
4,5
0,5
7
21
15,5
32
00132665
3/2-directional valve
0 bar / 16 bar
-10C / +50C
Medium
Compressed air
Compressed air
Nominal flow Qn
Weight
0.15 kg
00121338
Technical Remarks
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!
The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C.
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS, see chapter Technical information.
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
45
Valve systems Standardized valve systems
Operational
voltage
AC 50 Hz
DC
Voltage
tolerance
AC 50 Hz
24 V
42 V
-10% / +10%
-20% / +10%
230 V
110 V
DC
Operating voltage
DC
AC 50 Hz
Power
consumption
DC
W
Switch-on
power
AC 50 Hz
VA
Holding
power
AC 50 Hz
VA
-20% / +10%
10
-20% / +10%
10
6.7
Power
consumption
DC
[W]
Holding
power
AC 50 Hz
[VA]
Switch-on
power
AC 50 Hz
[VA]
6.7
Part No.
24 V
42 V
5420800390
230 V
10
5428200380
110 V
10
5428200370
Dimensions
D535_207
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
46
Valve systems Standardized valve systems
ISO 6952
electrical connections
-- / +50C
IP65
Duty cycle ED
100 %
P581_172
DC
Operational
voltage
AC 50 Hz
DC
Voltage
tolerance
AC 50 Hz
Power
consumption
DC
W
Switch-on
power
AC 50 Hz
VA
220 V
-10% / +10%
110 V
-10% / +10%
48 V
-10% / +10%
10
24 V
24 V
-10% / +10%
-10% / +10%
110 V
-10% / +10%
10
230 V
-10% / +10%
10
24 V
-10% / +10%
10
48 V
12 V
AC 50 Hz
Operational
voltage
DC
220 V
110 V
48 V
-
Weight
Note
Holding
power
AC 50 Hz
VA
-
Part No.
[kg]
0.054
0.054
24 V
0.051
0498317804
0498317707
0498317006
1)
0498318800
0498317502
110 V
0.051
0498317103
230 V
0.054
0498322506
24 V
0.054
48 V
12 V
0.054
0498316905
0498317618
0498317405
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
47
Valve systems Standardized valve systems
Dimensions
29,5
30
15
29
,5
2,25
16,6
17
22
00132664
II 2G Ex mb IIC T4 Gb
II 2D Ex mb tb IIIC T 130C Db IP65
-20C / +50C
Protection class
IP65
Duty cycle ED
100 %
Compatibility indexCI
14
00115846
DC
AC 50 Hz
Operational
voltage
AC 60 Hz
DC
Voltage
tolerance
AC 50 Hz
230 V
230 V
-10% / +10%
110 V
110 V
-10% / +10%
24 V
24 V
24 V
-10% / +10%
Power Switch-on
consumption
power
DC AC 50 Hz
W
VA
Holding
power
AC 50 Hz
VA
3.1
2.9
-10% / +10%
2.9
3.25
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
48
Valve systems Standardized valve systems
AC 50 Hz
DC
Operational
voltage
AC 60 Hz
Cable length L
Weight
[m]
[kg]
Part No.
230 V
230 V
0.38
1827414297
230 V
230 V
10
0.91
1827414298
110 V
110 V
0.38
1827414299
24 V
24 V
0.38
1827414301
24 V
24 V
10
0.91
1827414302
24 V
0.38
1827414303
24 V
10
0.91
1827414304
110 V
110 V
10
0.38
1827414300
Dimensions
67
14,8
1)
18
31,25
29,5
22
1,25
50
9,01
29,7
00129906
L = cable length
1) Cable ID band with serial number
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
49
Valve systems Standardized valve systems
-40C / +90C
Protection class
IP65
0.4 Nm
00110264_a
Technical Remarks
The specified protection class is only valid in assembled and tested state.
Cable
fitting
1
2
gn/ge
1
2
3
Operational
voltage
AC
DC
[V]
[V]
Max. current
Contact assignment
Cable exit
Protective
circuit
Part No.
[A]
M20x1,5
230
2+E
angled 90
Varistor
8941016112
M16x1,5
300
10
2+E
angled 90
1834484048
M16x1,5
300
10
3+E
angled 90
1834484059
M16x1,5
24
24
2+E
angled 90
Z-diode
1834484101
110
110
-
2+E
angled 90
Varistor
3+E
angled 90
1
2
3
gn/ge
M16x1,5
1
2
3
4
1
2
3
Part No.
1834484102
230
230
M20x1,5
24
suitable
cable- min./
max
LED status
display
Housing color
[mm]
8941016112
8 / 10
1834484103
8941012462
Weight
[kg]
4 positions each 90
1LED
Green
Transparent
0.025
Note
2); 4);
4); 5)
50
Valve systems Standardized valve systems
Part No.
suitable
cable- min./
max
[mm]
LED status
display
Housing color
Weight
[kg]
Note
1834484048
6/8
4 positions each 90
Black
0.03
2); 5)
1834484059
6/8
4 positions each 90
Black
0.03
2); 5)
1834484101
6/8
4 positions each 90
1LED
Yellow
Transparent
0.03
1834484102
6/8
1834484103
4 positions each 90
4.5 / 11
8941012462
2 LED
1 position
2 LED
Red
green/red
Transparent
Transparent
0.03
0.03
3); 6)
2); 5); 5)
2); 6)
1); 2);
4); 5)
Dimensions
281)
40
M3
10
M16x1,5
1,5
18
281)
5,5 1)
33
00110274
1) Max.
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
51
Valve systems Standardized valve systems
-20C / +80C
Protection class
IP67
0.4 Nm
00110292_b
Technical Remarks
The specified protection class is only valid in assembled and tested state.
Operational
voltage
max.
[V AC] [V DC]
1
2
LED status
Wire Cable
display cross-section length
L
[mm]
[m]
230
230
2+E
0.75
24
24
Z-diode
2+E
Yellow
0.75
230
230
Varistor
2+E
Red
0.75
2
gn/ge
Contact assignment
Weight
Part No.
[kg]
1
gn/ge
Protective
circuit
2
gn/ge
0.2
1834484160
0.2
1834484162
0.31
1834484163
0.2
1834484164
0.31
1834484165
Part No.
Fig.
Note
1834484160
Fig. 1
1)
Fig. 2
Fig. 2
1834484162
1834484163
1834484164
1834484165
1) Scope of delivery incl. flat gasket
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
52
Valve systems Standardized valve systems
Fig. 1
Fig. 2
31
26,5
26,5
44
M3
26,5
18
44
M3
26,5
29
18
29
1,5
1,5
1834484162-09
1834484162-09_a
-20C / +80C
Protection class
IP67
Cable exit
angled 90
Wire cross-section
0.75 mm
0.4 Nm
Materials:
Cable sheath
Polyvinyl chloride
00110292_a
Technical Remarks
For security reasons, the electrical connector must be plugged properly and centrically.
The specified protection class is only valid in assembled and tested state.
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
53
Valve systems Standardized valve systems
1
2
Max. current
[A]
Contact assignment
Cable length L
[m]
Weight
[kg]
Part No.
2+E
0.02
8946201912
1
2
gn/ge
Dimensions
32
21,5
1)
10
44
27
M3
1,5
5
1834484162-10_b
1) 0female insert
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
54
Valve systems Standardized valve systems
-25C / +50C
Protection class
IP65
Cable fitting
M16x1,5
0.4 Nm
Materials:
Housing
Polyamide
00110264_c
Technical Remarks
For security reasons, the electrical connector must be plugged properly and centrically.
The specified protection class is only valid in assembled and tested state.
Operational
voltage
1
2
1
2
gn/ge
Cable exit
Protective
circuit
suitable
cable- min./
max
Part No.
AC
[V]
DC
[V]
[A]
300
10
2+E
angled 90
4/8
1834484051
24
24
2+E
angled 90
Z-diode
6/8
1834484107
6/8
1834484108
4/8
1834484109
[mm]
110
230
2+E
angled 90
Varistor
Status display
LED status
display
Housing color
1834484051
Black
0.02
Fig. 1
1); 3)
1834484107
1LED
Yellow
Transparent
0.02
Fig. 2
2); 4)
1LED
Red
Transparent
0.02
Fig. 2
1834484108
1834484109
Weight
[kg]
Fig.
Note
1); 4)
2); 4)
1) Profile seal
2) Flat gasket
3)Seal:caoutchouc/butadiene caoutchouc
4)Seal:Silicone caoutchouc
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
55
Valve systems Standardized valve systems
Fig. 1
18
32
M3
28,6
51
5,5
2
11
20,8
D440_037_b
Fig. 2
M3
40
max.29
ca.10
M16x1,5
1,5
max.5,5
11
max.21
33
00110276
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
56
Valve systems Standardized valve systems
Pilot valve
581, Modular system Pilot valve width: 15 mm Manual override: without detent
Working pressure min./max.
0 bar / 10 bar
-10C / +50C
Medium
Compressed air
Status displayLED
Green
Duty cycle
100 %
Weight
P581_205
Technical Remarks
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!
The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C.
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS, see chapter Technical information.
Operational
voltage
DC
Power
consumption
DC
W
24 V
2.2
24 V
Operating
voltage
DC
Power
consumption
DC
[W]
Cable length
0.2
IP67
2.2
0.35
IP67
2.2
0.5
IP67
2.2
2.2
24 V
[m]
Protection
class
Weight
Fig.
Note
Part No.
0.05
Fig. 1
0493833308
0.056
Fig. 1
0493832506
0.058
Fig. 1
0493833103
IP67
0.1
Fig. 1
0493838601
IP65
0.04
Fig. 2
1); 2)
0493833502
[kg]
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
57
Valve systems Standardized valve systems
Fig. 1
15,2
46
L +10
-5
12 3
00132661
Pin assignment
1) +24 V
2) ground
3) 0 V
8,2
3,8
3,5
3,8
3,8
10,8
1,9
23,7
40,8
Fig. 2
9,7
15,2
M2,5
15,2
8,6
20,7
00132662
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
58
Valve systems Standardized valve systems
Electro module
-40C / +90C
Protection class
IP67
48 V DC
P590_006
Type
Max. current
[A]
10 outputs
2.1
Cable length L
[m]
Part No.
0493831909
10
0493832018
Dimensions
30
21
82,5
10 5
9,2
9 4
72,5
15
18,5
12
8 3
7 2
6 1
12 3 12 3
10
00133705
Pin assignment
1) +24 V
2) ground
3) 0 V
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
59
Valve systems Standardized valve systems
P590_043
Type
for double-sided electrically actuated valves,
15 pilot valve width
Weight
[kg]
Note
Part No.
0.03
1)2)3)
0493835718
Dimensions
24,05
19,55
1,5
13,1
M4 (x2)
17,2
12,7
15,2
12
2,5
60
11,7
24618
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
60
Valve systems Standardized valve systems
Blanking plug
for581
Ambient temperature
min./max.
-10C / +50C
P590_074
Type
Material
Note
Part No.
Weight
[kg]
Polyamide
0.006
1)
0493833405
1) quantity delivered 10
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
61
Valve systems Standardized valve systems
standard
ISO 5599-1
Ambient temperature
min./max.
-10C / +50C
Medium
Compressed air
50 m
P581_179
Working pressure
min./max.
[bar]
-0.95 / 10
Material
Surface
Aluminum
black anodized
Weight
[kg]
0.2
Dimensions
D581_180
Part No.
5801590000
A1
A2
70
85
40
Part No.
25
standard
ISO 5599-1
Ambient temperature
min./max.
-20C / +70C
Medium
Compressed air
50 m
P581_174
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
5801590000
62
Valve systems Standardized valve systems
Type
Material
Note
Part No.
Weight
[kg]
Aluminum
0.27
3)
5811100000
Aluminum
0.27
3)
5811200000
Aluminum
0.27
3)1)
5811300000
Aluminum
0.15
3)
5811400000
Aluminum
0.2
3)
5811500000
Aluminum
0.2
3)2)
5811600000
Aluminum
0.14
3)
5811700000
Aluminum
0.27
3)
5811800000
Weight
[kg]
Note
Part No.
1) The valve can be changed to a single solenoid version with air return.
2) signal 14 has priority
standard
ISO 5599-1
Ambient temperature
min./max.
-20C / +70C
Medium
Compressed air
50 m
P581_174
Type
Material
0.1
R402002299
0.09
R402002292
0.08
R402002293
0.08
1)
R402002294
0.14
2)
R402002297
0.09
R402002295
0.09
R402002298
0.09
R402002296
1) The valve can be changed to a single solenoid version with air return.
2) signal 14 has priority
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
63
Valve systems Standardized valve systems
standard
ISO 5599-1
Ambient temperature
min./max.
-20C / +70C
Medium
Compressed air
50 m
P581_163
Type
5/2-directional valve, single
solenoid
Weight
[kg]
Note
Part No.
15 mm
0.057
1)
0493842501
15 mm
0.054
1)
0493842609
22 mm
0.13
2)4)
5811010000
22 mm
0.15
2)4)
5811020000
22 mm
0.13
2)3)
5811050000
22 mm
0.15
2)3)
5811060000
all
30 mm
0.2
1)
5811080000
Weight
[kg]
Part No.
P581_046
Type
ISO 1 - 4
Delivery quantity
[Piece]
10
0.005
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
4634210000
64
Valve systems Standardized valve systems
P581_100
Weight
[kg]
0.014
Note
Part No.
1)
5811001000
Dimensions
00133204
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
65
Valve systems Standardized valve systems
P581_116
Material
Polyamide
Weight
[kg]
Note
Part No.
1)
5811000000
0.015
1) Delivered in pairs
for modification of a valve from with throttle set to without throttle set
P581_173
Type
Material
Part No.
Weight
[kg]
Nitrile rubber
0.005
0490429808
Nitrile rubber
0.005
0490429905
Nitrile rubber
0.001
0486715103
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
66
Valve systems Standardized valve systems
standard
ISO 5599-1
Ambient temperature
min./max.
-10C / +50C
Medium
Compressed air
50 m
P581_255
Port
Type
Delivery quantity
[Piece]
Weight
[kg]
Note
Part No.
G 1/2
0.63
5802960000
0.03
5802970000
10
0.02
3)
5802980000
G 3/8
End plate
0.34
5802950000
T581_287
1) intermediate plate
2) intermediate plate gasket
3) sealing strip
4) end plate
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
67
Valve systems Standardized valve systems
standard: ISO 5599-1 Frame size: ISO 1 Compressed air connection output: G 1/4 Reversed pressure
supply permissible
00107419
Standards
ISO 5599-1
-25C / +70C
-25C / +70C
Medium
Compressed air
On the side
On the side
On the side
On the side
On the side
Exhaust (3,5)
Materials:
Base plate
Die-cast aluminum
Technical Remarks
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!
The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C.
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS, see chapter Technical information.
For use with HV series valves, the ambient temperature is -25C to +200C and the medium temperature is -25C to +120C.
Reversed pressure supply is not permitted for HV series valves.
Frame size
ISO 1
Output
Exhaust
[1]
[2 / 4]
[3/ 5]
G 1/4
G 1/4
G 1/4
Pilot control
exhaust
[12]
G 1/8
Pilot connection
[14]
G 1/8
Grid dimension
Part No.
48
1825503143
Part No.
Weight
[kg]
1825503143
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
0.17
68
Valve systems Standardized valve systems
Dimensions
H5
H4
H3
H3
D1
12
L6
L5
L4
L3
D2
L2
L1
D2
2
4
D3
14
H2
B1
H1
D581_140
B1
48
H1
H2
1825503143
Part No.
Part No.
L4
L5
L6
1825503143
98
24
58
32
H3
10
11,5
H4
21.5
H5
23.5
D1
D2 *)
5.5
G 1/4
D3 *)
G 1/8
L1
84
L2
43
L3
110
Weight
kg
0.17
*) Ports
standard: ISO 5599-1 Frame size: ISO 1 Compressed air connection output: G 1/4 Reversed pressure
supply permissible
5746-121
Standards
ISO 5599-1
-25C / +70C
-25C / +70C
Medium
Compressed air
-0.95 bar / --
Down
Down
Down
Down
Down
Exhaust (3,5)
Materials:
Base plate
Die-cast aluminum
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
69
Valve systems Standardized valve systems
Technical Remarks
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!
The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C.
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS, see chapter Technical information.
For use with HV series valves, the ambient temperature is -25C to +200C and the medium temperature is -25C to +120C.
Reversed pressure supply is not permitted for HV series valves.
Frame size
Input
Output
Exhaust
[1]
[2 / 4]
[3/ 5]
ISO 1
G 1/4
G 1/4
G 1/4
Weight
Part No.
[kg]
G 1/8
0.196
1825503201
Dimensions
D898_111
B1
46
B2
7
B3
11.5
D1
D2 *)
D3 *)
1825503201
Part No.
Part No.
L4
L5
L6
L7
L8
1825503201
49
23
11,5
31
Weight
kg
5.5
G 1/4
G 1/8
H1
30
H2
10
H3
5
L1
110
0.196
*) Ports
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
L2
55
L3
49
70
Valve systems Standardized valve systems
standard: ISO 5599-1 Frame size: ISO 1 Compressed air connection output: G 1/8 - 8
5810-491
Standards
ISO 5599-1
-20C / +70C
-20C / +70C
Medium
Compressed air
-1 bar / 16 bar
Surface
painted
On the side
On the side
On the side
On the side
Exhaust (3,5)
Materials:
Base plate
Technical Remarks
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!
The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C.
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS, see chapter Technical information.
Frame size
Input
[1]
Output
[2 / 4]
G 1/4
G 1/8
ISO 1
G 1/8
Weight
Part No.
[kg]
G 1/8
G 1/8
0.11
5801710000
G 1/4
G 1/4
G 1/8
0.17
5801740000
0.13
5801810000
0.22
5801770000
Dimensions
D581_029
Part No.
5801710000
A *)
B *)
ISO 1
G 1/8
G 1/8
70
40
20
26.5
18
L
2
84
5801740000
ISO 1
G 1/4
G 1/8
70
40
23
11
31.5
11.5
23
96
5801810000
ISO 1
70
40
20
26.5
18
84
5801770000
ISO 1
70
40
23
10
31.5
11.5
23
96
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
71
Valve systems Standardized valve systems
Part No.
5801710000
96
5.4
40
10
5801740000
110
5.4
46
64
21
12
Weight
kg
0.11
0.17
5801810000
96
5.4
40
10
0.13
5801770000
110
5.4
46
64
21
12
0.22
*) Ports
standard: ISO 5599-1 Frame size: ISO 1 Compressed air connection output: G 1/8 - 6
5810-481
Standards
ISO 5599-1
-20C / +70C
-20C / +70C
Medium
Compressed air
-1 bar / 16 bar
Surface
painted
Down
Down
Down
Down
Exhaust (3,5)
uncollected exhaust
Ports separated
Materials:
Base plate
Technical Remarks
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!
The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C.
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS, see chapter Technical information.
Frame size
ISO 1
Input
[1]
Output
[2 / 4]
G 1/8
G 1/8
G 1/8
Weight
Part No.
[kg]
0.11
5801700000
0.13
5801800000
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
72
Valve systems Standardized valve systems
Dimensions
D581_027
ISO 1
G1/8
G1/8
70
40
20
F
8
26.5
H
9
18
5801700000
Part No.
A *)
B *)
84
5801800000
ISO 1
70
40
20
26.5
18
84
Part No.
5801700000
96
5.4
40
5801800000
96
5.4
40
Weight
kg
0.11
0.13
*) Ports
standard: ISO 5599-1 Frame size: ISO 1 Compressed air connection output: G 1/8
Standards
ISO 5599-1
-20C / +70C
-20C / +70C
Medium
Compressed air
-1 bar / 16 bar
Surface
P523_014
black anodized
Materials:
Base plate
Seals
Technical Remarks
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!
The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C.
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS, see chapter Technical information.
Frame size
ISO 1
Input
Output
[1]
[2 / 4]
G 1/8
G 1/8
G 1/8
Weight
[kg]
0.175
Note
Part No.
1)
5801690000
1) 32 - 125 mm
2) 63 - 125 mm
Scope of delivery incl. mounting screws
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
73
Valve systems Standardized valve systems
Dimensions
D581_037
Part No.
1, 4, 3, (5)
G 1/8
2*
5801690000
ISO 1
G 1/8, G 1/4
Part No.
5801690000
15
17
40
32
12, 14
G 1/8
93.5
80
62
35
Weight
kg
0.175
* Two different threaded banjo bolts are supplied with 5801690000 to be used with different cylinders.
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
20
74
Valve systems Standardized valve systems
standard: ISO 5599-1 Frame size: ISO 1 type F Compressed air connection output: G 1/4 Can be
assembled into blocks Single base plate principle Reversed pressure supply permissible With collective
pilot air exhaust
00107662
Standards
-25C / +70C
-25C / +70C
Medium
Compressed air
Grid dimension
82 mm
On the side
On the side
Down
On the side
On the side
Exhaust (3,5)
Materials:
Base plate
Die-cast aluminum
Seals
Technical Remarks
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!
The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C.
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS, see chapter Technical information.
Frame size
Output
ISO 1
[2 / 4]
G 1/4
G 1/8
0 / 16
Weight
Part No.
[kg]
0.246
1825503144
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
75
Valve systems Standardized valve systems
Dimensions
D
E1
E3
F2
S
R
F4
H2
F3 F3
H2
H1
H1
E2
F1
G1
T
W
G2
U
V
G3
00107666_a
Part No.
1825503144
Part No.
110
G2
95
G3
5,5
14
13,5
11,25
H1
26,5
H2
1825503144
Part No.
1825503144
1,5
43
G 1/4
18
E1
16,5
G 1/8
E2
16,5
44
E3
11,25
22
F1
3
85
F2
4,5
M5
F3
9
7,5
Weight
kg
0.246
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
F4
M5
13
G1
3
71
76
Valve systems Standardized valve systems
standard: ISO 5599-1 Frame size: ISO 1 type F Can be assembled into blocks Base plate principle,
multiple Reversed pressure supply permissible
00107661
Standards
-25C / +70C
-25C / +70C
Medium
Compressed air
0 bar / 16 bar
On the side
On the side
Exhaust (3,5)
Materials:
Base plate
Die-cast aluminum
Seals
Technical Remarks
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!
The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C.
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS, see chapter Technical information.
Frame size
ISO 1
Input
[1]
G 3/8
G 3/8
Weight
Part No.
[kg]
0.208
1825503145
Dimensions
00107701_a
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
77
Valve systems Standardized valve systems
G 3/8
C1
1825503145
Part No.
Part No.
H2
H3
1825503145
22
46
28
28
D1
E1
E2
85
24
22,1
24
28
11
22
F2
5,5
G1
110
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
G2
95
Weight
kg
0.208
H1
22
78
Valve systems Standardized valve systems
standard: ISO 5599-1 Frame size: ISO 1 type G Compressed air connection output: G 1/4 Can be
assembled into blocks
Standards
ISO 5599-1
-20C / +70C
-20C / +70C
Medium
Compressed air
-1 bar / 16 bar
Down
Exhaust (3,5)
uncollected exhaust
Ports separated
5811_092_a
Materials:
Base plate
Die-cast aluminum
Seals
Technical Remarks
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!
The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C.
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS, see chapter Technical information.
Frame size
ISO 1
Input
[1]
G 1/4
G 1/8
Weight
Part No.
[kg]
0.23
5801500000
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
79
Valve systems Standardized valve systems
Dimensions
S
J
F
B1
12
C
E E
14
G1/8
1
G
B1
N
D581_110
Part No.
5801500000
ISO 1
2 x G 1/4
3 x G 3/8
B1
3 x G 1/4
5.5
11
5.5
22
Weight
kg
Part No.
5801500000
12
n x 43 + 44
12
36
22
45.7
17
106
0.23
n = number of subbases
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
92
24
80
Valve systems Standardized valve systems
standard: ISO 5599-1 Frame size: ISO 1 type G Can be assembled into blocks Base plate principle,
multiple Reversed pressure supply permissible
Standards
ISO 5599-1
-20C / +70C
-20C / +70C
Medium
Compressed air
-1 bar / 16 bar
Exhaust (3,5)
uncollected exhaust
Ports separated
5811_092_b
Materials:
Base plate
Die-cast aluminum
Seals
Technical Remarks
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!
The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C.
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS, see chapter Technical information.
Frame size
ISO 1
Input
[1]
G 3/8
G 3/8
Weight
Part No.
[kg]
0.26
5801510000
Delivered in pairs with all ports closed. Porting can be in end, top, or bottom (both ends). Porting is selected by drilling through dimensions B*, B1*, or U* on
drawing below.
Scope of delivery incl. seal and mounting screws
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
81
Valve systems Standardized valve systems
Dimensions
S
J
F
B1
12
C
E E
14
G1/8
B1
N
D581_110
Part No.
B*
2 x G 1/4
3 x G 3/8
B1*
3 x G 1/4
5.5
11
5.5
5801510000
ISO 1
22
92
Part No.
U*
5801510000
12
n x 43 + 44
12
36
22
45.7
17
106
3 x G 3/8
n = number of subbases
*Dimensions B, B1, and U are prepared with threaded connections but must be drilled through as required for the desired porting configuration.
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
24
Weight
kg
0.26
82
Valve systems Standardized valve systems
standard: ISO 5599-1 Frame size: ISO 1 type H Compressed air connection output: G 1/4 Can be
assembled into blocks
Standards
-15C / +70C
-15C / +80C
Medium
Compressed air
0 bar / 16 bar
Grid dimension
43 mm
Mounting screw
00107432
Materials:
Housing
Die-cast aluminum
Base plate
Die-cast aluminum
Seals
Technical Remarks
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!
The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C.
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS, see chapter Technical information.
Frame size
Input
Output
[1]
[2 / 4]
ISO 1
G 1/4
G 1/4
Weight
M5
G 1/4
Fig.
Note
Part No.
0.24
Fig. 1
1)
1825503286
0.24
Fig. 2
2)
1825503288
0.27
Fig. 3
3)
1825503290
0.27
Fig. 4
4)
1825503292
[kg]
1) Ports 2 and 4 on side, control pressure connection 12 and 14: single connection
2) Ports 2 and 4 on side, control pressure connection 12 and 14: central manifold
3) Ports 2 and 4 on side, 1,2 and 4 also on bottom, control pressure connection 12 and 14: single connection
4) Ports 2 and 4 on side, 1,2 and 4 also on bottom, control pressure connection 12 and 14: central manifold
Scope of delivery incl. seal and mounting screws
00107438
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
83
Valve systems Standardized valve systems
00107444_a
00107441
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
84
Valve systems Standardized valve systems
00107444_b
Fig. 3,Ports 2 and 4 on side, 1,2 and 4 also on bottom,Control pressure connection 12+14: single connection
00107440
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
85
Valve systems Standardized valve systems
00107445
Fig. 4,Ports 2 and 4 on side, 1,2 and 4 also on bottom,Control pressure connection 12+14: central manifold
00107441
standard: ISO 5599-1 Frame size: ISO 1 type H Can be assembled into blocks
Standards
-15C / +70C
-15C / +70C
Medium
Compressed air
0 bar / 16 bar
Mounting screw
Exhaust (3,5)
00107431
Materials:
Base plate
Die-cast aluminum
Seals
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
86
Valve systems Standardized valve systems
Technical Remarks
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!
The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C.
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS, see chapter Technical information.
Frame size
ISO 1
Input
Exhaust
[1]
[3/ 5]
G 3/8
G 3/8
G 1/8
Weight
Fig.
Part No.
0.404
Fig. 1
1825503294
0.382
Fig. 2
1825503297
[kg]
Dimensions
00107435
n
X
150
193
236
n*43+64
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
87
Valve systems Standardized valve systems
00107436
00107442
00107437
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
88
Valve systems Standardized valve systems
00107443
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
89
Valve systems Standardized valve systems
standard: ISO 5599-1 Frame size: ISO 1 type K Compressed air connection output: G 1/8 - 6 Can be
assembled into blocks
Standards
ISO 5599-1
-20C / +70C
-20C / +70C
Medium
Compressed air
-1 bar / 16 bar
Surface
painted
Down
Exhaust (3,5)
uncollected exhaust
Ports separated
5810_302_b
Materials:
Base plate
Seals
Technical Remarks
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!
The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C.
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS, see chapter Technical information.
Frame size
Port
Output
[2 / 4]
Pilot connection
[14]
G 1/8
G 1/4
G 1/8
G 1/4
G 1/8
ISO 1
Weight
Part No.
[kg]
0.14
5801720000
0.27
5801750000
0.3
5801780000
0.16
5801820000
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
90
Valve systems Standardized valve systems
Dimensions
D581_231_a
* n = Number of subbases.
** Alternative port openings, closed with plugs
Part No.
5801720000
ISO 1
G 1/8
G 1/4
G 1/4
G 1/8
22
28.5
9.5
29.5
14.5
100
5801750000
ISO 1
G 1/4
G 3/8
G 3/8
G 1/8
27
40
12.5
26.5
20
122
5801780000
ISO 1
G 3/8
G 3/8
27
40
12.5
26.5
20
122
5801820000
ISO 1
G 1/4
G 1/4
22
28.5
9.5
29.5
14.5
100
Part No.
AA
5801720000
25
27
43
41
14
27.5
72
5.4
5801750000
30
34
43
49
15
34
94
6.4
10
Weight
kg
0.14
0.27
5801780000
30
34
43
49
15
34
94
6.4
10
0.3
5801820000
25
27
43
41
14
27.5
72
5.4
13.5
0.16
* Intermediate plates designated with the same letters (a-d) can be mounted together without a transition plate.
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
91
Valve systems Standardized valve systems
standard: ISO 5599-1 Frame size: ISO 1 type K Compressed air connection output: G 1/8 - G 1/4 Can
be assembled into blocks
5810_302_b
Standards
ISO 5599-1
-20C / +70C
-20C / +70C
Medium
Compressed air
-1 bar / 16 bar
Surface
painted
Down
Down
Down
Down
Exhaust (3,5)
uncollected exhaust
Ports separated
Materials:
Base plate
Seals
Technical Remarks
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!
The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C.
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS, see chapter Technical information.
Type
Intermediate plate
for separate air
supply
Frame size
Input
[1]
ISO 1
G 1/8
G 1/4
G 1/4
G 1/8
Port
G 1/4
Weight
Part No.
[kg]
0.14
5801670000
0.27
5801680000
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
92
Valve systems Standardized valve systems
Dimensions
D581_231_a
* n = number of subbases.
** Alternative port openings, closed with plugs.
*** Only on subbases with separate intake.
**** Subbase 5801680000 can also be connected to port 3 and 5.
Part No.
5801670000
ISO 1
G 1/8
G 1/4
G 1/4
G 1/8
22
28.5
9.5
29.5
14.5
100
25
5801680000
ISO 1
G 1/4
G 3/8
G 3/8
G 1/8
27
40
12.5
26.5
20
122
30
Part No.
AA
5801670000
27
43
41
14
27.5
72
5.4
5801680000
34
43
49
15
34
94
6.4
10
Weight
kg
0.14
0.27
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
93
Valve systems Standardized valve systems
standard: ISO 5599-1 Frame size: ISO 1 type K Can be assembled into blocks
Standards
ISO 5599-1
-20C / +70C
-20C / +70C
Medium
Compressed air
-1 bar / 16 bar
Surface
painted
Exhaust (3,5)
uncollected exhaust
Ports separated
Materials:
5810_302_e
Base plate
Seals
Technical Remarks
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!
The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C.
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS, see chapter Technical information.
Frame size
ISO 1
Input
[1]
Weight
0.15
5801850000
0.08
5801860000
G 1/4
G 1/4
Part No.
[kg]
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
94
Valve systems Standardized valve systems
Dimensions
D581_231_d
* n = Number of subbases.
** Alternative port openings, closed with plugs
ISO 1
G 1/4
G 1/4
22
14.5
100
25
27
41
5801850000
Part No.
27.5
72
5801860000
ISO 1
100
25
41
14
27.5
72
Part No.
5801850000
5.4
5801860000
5.4
Weight
kg
0.15
0.08
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
95
Valve systems Standardized valve systems
Blanking plate
ISO 5599-1
-20C / +70C
-20C / +70C
Medium
Compressed air
-1 bar / 16 bar
5810-321
Materials:
Housing
Base plate
Die-cast aluminum
Seals
Technical Remarks
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!
The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C.
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS, see chapter Technical information.
Frame size
Weight
[kg]
ISO 1
0.055
Dimensions
00128858
Part No.
5801870000
69
39
Weight
kg
0.055
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
Part No.
5801870000
96
Valve systems Standardized valve systems
Blanking plate
ISO 5599-1
+0C / +80C
+0C / +80C
Medium
Compressed air
Mounting screw
Materials:
Seals
00104044
Technical Remarks
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!
The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C.
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS, see chapter Technical information.
Type
Frame size
Blanking plate
ISO 1
Gasket ISO 1
Weight
[kg]
Part No.
0.072
1825503282
1821015028
Dimensions
A
A
D
IM0045542
Part No.
1825503282
ISO 1
14
18
C
9
D
7
42
80
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
97
Valve systems Standardized valve systems
Throttle plate
ISO 5599-1
+0C / +80C
+0C / +80C
Medium
Compressed air
0 bar / 16 bar
Materials:
Base plate
Aluminum
Seals
00107463
Technical Remarks
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!
The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C.
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS, see chapter Technical information.
Frame size
Weight
[kg]
Part No.
ISO 1
0.255
0821201023
Dimensions
00107465_a
Part No.
0821201023
16.3
11,1
105.6
95.6
80
F
3
26,5
G1
8.5
26.5
4.5
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
K
9
K1
10.8
98
Valve systems Standardized valve systems
Part No.
0821201023
16.3
28
5.5
Part No.
Z1
0821201023
25
40
M5
M59
5.2
36
18
SW1
18
SW2
3
27
U
9
W
9
Weight
kg
0.255
-- / 16 bar
+5C / +50C
Medium
Compressed air
5 m
0 mg/m - 5 mg/m
Materials:
00123548
Housing
Zinc
Seals
Butadiene rubber
Controlled
port
[bar]
ISO 1
0.5 / 12
Weight
Fig.
[kg]
1.15
1.19
Fig. 1
Note
Part No.
1)
0821302048
2)
0821302060
1)
0821302054
2)
0821302062
1)
0821302057
2)
0821302063
1)
0821302051
2)
0821302061
14 5 4 1 2 3 12
1.15
ISO 1
0.5 / 12
1.19
Fig. 1
1.15
ISO 1
0.5 / 12
ISO 1
0.5 / 12
2, 4
1.19
Fig. 1
1.57
1.61
Fig. 2
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
99
Valve systems Standardized valve systems
00107461
00107673
controlled connection 1
Controlled connection 2
Controlled connection 4
Fig. 1
40
J
00107462_a
B5
82
C5
D5
E7
G5
H5
I2.5
8
J5
42.5
K2.5
L2.5
M5
0821302048
Part No.
0821302060
25
186
27
45
97,5
42.5
14
18
36
0821302054
82
38,5
199
27
45
97,5
42.5
14
18
36
0821302062
25
199
27
45
97,5
42.5
14
18
36
38,6
186
27
45
97,5
14
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
18
36
100
Valve systems Standardized valve systems
Fig. 2
J
00107462_b
B5
164
C5
D5
E7
G5
H5
I2.5
8
J5
42.5
K2.5
L2.5
M5
0821302051
Part No.
0821302061
25
292
27
45
42.5
14
18
36
38,6
292
27
45
96,5
14
18
36
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
101
Valve systems Standardized valve systems
Transition plate
standard: ISO 5599-1 Frame size: ISO 1 - ISO 2 type G Can be assembled into blocks Reversed
pressure supply permissible
Standards
-20C / +70C
-20C / +70C
Medium
Compressed air
-1 bar / 16 bar
Surface
painted
Exhaust (3,5)
uncollected exhaust
Ports separated
5746-141
Materials:
Base plate
Seals
Technical Remarks
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!
The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C.
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS, see chapter Technical information.
The transition plate is used for combining subbases of different sizes in the same manifold.
Frame size
Weight
[kg]
ISO 1, ISO 2
0.27
Dimensions
D898_146_a
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
Part No.
5802520000
102
Valve systems Standardized valve systems
Supply plate
standard: ISO 5599-1 Frame size: ISO 1 type F Reversed pressure supply permissible
Standards
ISO 5599-1
-25C / +70C
-25C / +70C
Medium
Compressed air
Mounting screw
hexagon head
Down
Down
Ports separated
5746-171
Materials:
Base plate
Aluminum
Seals
Technical Remarks
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!
The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C.
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS, see chapter Technical information.
Frame size
ISO 1
Input
[1]
G 3/8
Weight
Part No.
[kg]
G 3/8
0.395
8985041162
Dimensions
D581_190
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
103
Valve systems Standardized valve systems
Transition plate
standard: ISO 5599-1 Frame size: ISO 1 -> ISO 2 type F Can be assembled into blocks Reversed
pressure supply permissible
00107448
Standards
ISO 5599-1
-15C / +70C
-15C / +80C
Medium
Compressed air
Mounting screw
hexagon head
Exhaust (3,5)
uncollected exhaust
Ports separated
Materials:
Housing
Aluminum
Base plate
Aluminum
Seals
Technical Remarks
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!
The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C.
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS, see chapter Technical information.
Frame size
Weight
[kg]
0.295
00107450
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
Part No.
1825503164
104
Valve systems Standardized valve systems
Transition plate
standard: ISO 5599-1 Frame size: ISO 1 -> ISO 3 - ISO2 -> ISO 3 type F Can be assembled into blocks
Reversed pressure supply permissible
00107448
Standards
ISO 5599-1
-15C / +70C
-15C / +80C
Medium
Compressed air
Mounting screw
hexagon head
Exhaust (3,5)
uncollected exhaust
Ports separated
Materials:
Housing
Aluminum
Base plate
Aluminum
Seals
Technical Remarks
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!
The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C.
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS, see chapter Technical information.
Frame size
ISO 1 -> ISO 3
ISO2 -> ISO 3
Weight
[kg]
Fig.
Part No.
0.825
Fig. 1
1825503166
0.79
Fig. 2
1825503165
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
105
Valve systems Standardized valve systems
Fig. 1
ISO3
ISO1
55
32
32
ISO3
35
190
168
28
24
95
24
M5
M8
ISO1
25
7
15.5
00107451
Fig. 2
ISO3
ISO2
32
190
43
43
168
35
31.5
115
31.5
M6
25
M8
55
32
32
34
25.5
9
23.5
29
00107452
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
106
Valve systems Standardized valve systems
standard: ISO 5599-1 Frame size: ISO 1 - ISO 2 type F Can be assembled into blocks Reversed
pressure supply permissible
00107661
Standards
ISO 5599-1
-15C / +70C
-15C / +80C
Medium
Compressed air
Mounting screw
hexagon head
On the side
On the side
Exhaust (3,5)
Materials:
Base plate
Die-cast aluminum
Seals
Technical Remarks
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!
The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C.
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS, see chapter Technical information.
Frame size
Weight
[kg]
ISO 1, ISO 2
0.255
Part No.
1825503244
Scope of delivery: 2 end plates of different sizes including seal and mounting screws
00107457_a
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
107
Valve systems Standardized valve systems
Angle subplate
standard: ISO 5599-1 Frame size: ISO 1 type F Compressed air connection output: G 1/4
P581_185
Standards
ISO 5599-1
-15C / +80C
-15C / +80C
Medium
Compressed air
0 bar / 10 bar
Mounting screw
On the side
Materials:
Base plate
Aluminum
Seals
Technical Remarks
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!
The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C.
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS, see chapter Technical information.
Frame size
ISO 1
G 1/4
Weight
Note
Part No.
0.413
1825503170
0.401
1)
1825503324
[kg]
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
108
Valve systems Standardized valve systems
Dimensions
00108449
Part No.
1825503170
37
25
12
22
G 1/4
5,7
10
5,5
110
95
71
13
1825503324
37
25
12
22
G 1/4
5,7
10
5,5
110
95
71
13
Part No.
1825503170
1,5
7,5
42
81
1825503324
1,5
7,5
42
81
Weight
kg
0.413
0.401
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
109
Valve systems Standardized valve systems
Supply plate
standard: ISO 5599-1 Frame size: ISO 1 type F Reversed pressure supply permissible
Standards
ISO 5599-1
-25C / +70C
-25C / +70C
Medium
Compressed air
Mounting screw
hexagon head
Down
Down
Ports separated
5746-171
Materials:
Base plate
Aluminum
Seals
Technical Remarks
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!
The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C.
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS, see chapter Technical information.
Frame size
ISO 1
Input
[1]
G 3/8
Weight
Part No.
[kg]
G 3/8
0.395
Dimensions
D581_190
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
8985041162
110
Valve systems Standardized valve systems
Blanking piece
00106827
6,8
Part No.
Frame size
ISO 1
1820220021
Part No.
Ambient temperature
min./max.
-15 / 80
1820220021
D2
D1
Type
16.6
Material
Material
Seal
Weight
[kg]
Aluminum
Acrylonitrile Butadiene
Rubber
0.008
00130480
D1
11.8
D2
15.8
00136404
Part No.
Frame size
Type
1827009767
ISO 1
Mounting screw
R412000918
ISO 1
Delivery
quantity
[Piece]
10
50
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
111
Valve systems Standardized valve systems
P581_191
D581_192
Part No.
Frame size
D1
D2
8985049012
ISO 1
6.2
12.2
14.8
16.5
8985049022
ISO 2
6.2
15.7
18.3
23
-25 / 70
8985049032
ISO 3
6.9
25.1
27.7
30
-25 / 70
Part No.
Material
Material
Seal
8985049012
Brass
Acrylonitrile Butadiene
Rubber
8985049022
Brass
Acrylonitrile Butadiene
Rubber
8985049032
Brass
Acrylonitrile Butadiene
Rubber
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
Ambient temperature
min./max.
-25 / 70
112
Valve systems Standardized valve systems
Supply plate
standard: ISO 5599-1 Frame size: ISO 1 type H Can be assembled into blocks Plate principle
Standards
Medium
Compressed air
1 bar / 10 bar
Grid dimension
30 mm
Mounting screw
Up
Exhaust (3,5)
00107433
Materials:
Housing
Aluminum
Base plate
Aluminum
Seals
Technical Remarks
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!
The pressure dew point must be at least 15 C under ambient and medium temperature and may not exceed 3 C.
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS, see chapter Technical information.
Frame size
ISO 1
Input
[1]
G 3/8
G 3/8
Weight
Part No.
[kg]
0.22
1825503314
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
113
Valve systems Standardized valve systems
Dimensions
00107446
Fig. 2
Fig. 1
5
21281
21486
Part No.
Type
1821015047
1821015043
Ambient temperature
min./max.
Material
Seal
Weight
[kg]
-20 / 70
Acrylonitrile Butadiene
Rubber
0.004
-20 / 70
Acrylonitrile Butadiene
Rubber
0.01
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
Delivery
quantity
[Piece]
Fig.
Fig. 1
Fig. 2
114
Valve systems Standardized valve systems
Separator set
13,2
P581_033_1
23426
Part No.
Frame size
5801880000
ISO 1
Ambient temperature
min./max.
-20 / 70
Material
Weight
[kg]
Brass
0.012
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2016-10-28, AVENTICS S. r.l., subject to change
AVENTICS GmbH
Ulmer Strae 4
30880 Laatzen, GERMANY
Phone +49 511 2136-0
Fax +49 511 2136-269
www.aventics.com
info@aventics.com
Find more contact information at
www.aventics.com/contact
28-10-2016
An example configuration is depicted on the title page. The delivered product may thus vary from that in the
illustration. Subject to change. AVENTICS S. r.l.
This document, as well as the data, specifications and other information set forth in it, are the exclusive property of
AVENTICS S. r.l.. It may not be reproduced or given to third parties without its consent. PDF online