Академический Документы
Профессиональный Документы
Культура Документы
CaseReport
StreamReport
EquipmentReport:AIR
EquipmentReport:BFWPMP
EquipmentReport:CND1
EquipmentReport:CNDPMP
EquipmentReport:DA1
EquipmentReport:ECON
EquipmentReport:FB1
EquipmentReport:FWH1
EquipmentReport:FWH2
EquipmentReport:FWH3
EquipmentReport:FWH5
EquipmentReport:FWH6
EquipmentReport:FWH7
EquipmentReport:FWH8
EquipmentReport:GEN1
EquipmentReport:HPSH
EquipmentReport:HPSPRY
EquipmentReport:HPST
EquipmentReport:HX1
EquipmentReport:IPSH
EquipmentReport:IPSPRY
EquipmentReport:IPST
EquipmentReport:LPST
EquipmentReport:M1
EquipmentReport:MU1
EquipmentReport:RCYPMP
EquipmentReport:SP1
EquipmentReport:SP2
EquipmentReport:SP3
EquipmentReport:SP4
EquipmentReport:SRC1
EquipmentReport:STACK
EquipmentReport:V1
GateCycleReport
Report
Model:sistempltubantenCase:sistempltu
10/26/201613:27:25
banten
PreparedusingGateCycleVersion
6.1.0.0
DateandTimeofLastRun
10/18/1616:14
LastExecutionStatus
Converged
OverallSystemResults
ModelID
CaseID
CaseDescription
CaseNotes
sistempltubanten
sistempltubanten
ProgramExecutionData
ExecutionStatus
Converged
ExecutionTime
00:00:03
IterationsUsed
FinalIterationResidual
26
1.1196E-06
FinalIterationWarnings
FinalIterationErrors
SystemTolerance
0.0001
PropertyCalcs.Tolerance
0.0001
NumberofActiveMacrosUsed
MaximumMacroResidual
MainInputs
CaseDescription
CaseNotes
General
CaseDesignMode
ControlledbyEquipmentInputs
Onlykeymessagesanderror
messages
IncludeMacroReports
1993ASMEsteamproperty
formulations
Weiss-PriceEmpiricalFit
NASAProperties:S.Gordon,B.J.
McBride
IdealGas-NoRealGas
Corrections
UseDefaultReferenceConditions
MoleFractions
LogFileOutputFlag
ReportOutputFlag
Properties
SteamPropertyMethod
SaltWaterBoilingPointMethod
GasPropertyMethod
RealGasPropertyMethod
ReferenceConditionsMethod
SystemGas
FuelGasCompositionFlag
FuelGasO2MoleFraction
0 fraction
FuelGasN2MoleFraction
0 fraction
FuelGasH2OMoleFraction
0 fraction
FuelGasCOMoleFraction
0 fraction
FuelGasCO2MoleFraction
0 fraction
FuelGasCH4MoleFraction
1 fraction
FuelGasH2MoleFraction
0 fraction
FuelGasARMoleFraction
0 fraction
FuelGasCOSMoleFraction
0 fraction
FuelGasH2SMoleFraction
0 fraction
FuelGasSO2MoleFraction
0 fraction
FuelGasMethanolMoleFraction
0 fraction
FuelGasEthaneMoleFraction
0 fraction
FuelGasEthylene(C2H4)MoleFraction
0 fraction
FuelGasAcetylene(C2H2)MoleFraction
0 fraction
FuelGasEthanolMoleFraction
0 fraction
FuelGasPropaneMoleFraction
0 fraction
FuelGasPropanolMoleFraction
0 fraction
FuelGasn-ButaneMoleFraction
0 fraction
FuelGasn-PentaneMoleFraction
0 fraction
FuelGasNeo-PentaneMoleFraction
0 fraction
FuelGasn-Hexane(gas)MoleFraction
0 fraction
FuelGasn_HeptaneMoleFraction
0 fraction
FuelGasn-OctaneMoleFraction
0 fraction
FuelGasDecaHydroNaphtaleneMoleFraction
0 fraction
FuelGasNaphtaleneMoleFraction
0 fraction
FuelGasDistillateMoleFraction
0 fraction
FuelGasHCNMoleFraction
0 fraction
FuelGasNH3MoleFraction
0 fraction
FuelGasNOMoleFraction
0 fraction
FuelGasNO2MoleFraction
0 fraction
FuelGasMethylMercaptane(CH4S)MoleFraction
0 fraction
FuelGasHeatingValueFlag
InputLowerHeatingValue(LHV)
FuelGasLowerHeatingValue(LHV)
50044 kJ/kg
Miscellaneous
STGeneratorEfficiency
0.98
BOPLossasSTPowerFraction
0 fraction
BOPLossasFixedValue
IgnoreCompressorPowerRequirement
0 kW
UnChecked
ControlledbyEquipmentInputs
UnChecked
UnChecked
SystemEnergyLossMethod
UsePerformanceFactorsFlag
TurnAllMacrosOffFlag
Convergence
MaximumSystemIterations
100
MinimumSystemIterations
MaximumPropertyIterations
30
GasPathIters/SystemIter
PropertyCalcs.Tolerance
0.0001
SystemTolerance
0.0001
PressureControlRes.Trig.
0.5
EvaporatorFlowDampingFactor
0.5
TubeLevelControlRes.Trig.
0.005
Ambient
AmbientTemperature
AmbientPressureMethod
28.5 C
AmbientPressure
AmbientPressure
101.0112 kPa
AmbientHumidityMethod
RelativeHumidity
AmbientRelativeHumidity
0.7851
AmbientAirCompositionMethod
OriginalMethod
OriginalMethod(steamtables)
AmbientAirVaporPressureMethod
UserVariables
CurrentValues
PowerofSteamCycle
STShaftPower
650411.8 kW
STGeneratorOutput
643907.6 kW
NetSteamCyclePower
625016.4 kW
PowerofGasCycle
GTShaftPower
0 MW
NetGasTurbinePower
0 MW
OverallPlantPower
NetCyclePower
625.0164 MW
LossesofSteamCycle
STGeneratorLosses
6504.111 kW
SteamCycleBOPLosses
18891.26 kW
LossesofGasCycle
GTGeneratorLosses
0 kW
GTAuxiliaryandBOPLosses
0 kW
LHVEnergyInput
TotalLowerHeatingValue(LHV)FuelCons.
1563107 kJ/sec
FuelCons.inDuctBurners
1563107 kJ/sec
Efficiency&HeatRate
GTSimple-CycleLowerHeatingValue(LHV)Efficiency
NetCycleLowerHeatingValue(LHV)Efficiency
NetCycleLowerHeatingValue(LHV)HeatRate
AdjustedCycleLowerHeatingValue(LHV)Efficiency
Adj.CycleLowerHeatingValue(LHV)HeatRate
0
39.984
9003.258 kJ/kW-hr
39.984
9003.258 kJ/kW-hr
CreditsappliedforadjustedEfficiency&HeatRate
CreditforEquivalentPower
0 kW
CreditforEquivalentFuel
0 kJ/sec
AmbientConditions
AmbientTemperature
28.5 C
WetBulbTemperature
25.4819 C
DewPointTemperature
24.3961 C
AmbientPressure
101.0112 kPa
EquivalentElevation
26.1882 m
AmbientRelativeHumidity
0.7851
AmbientAirH2OMoleFraction
0.0302 fraction
BalanceofPlantCalculations
IgnoreCompressorPowerRequirement
UnChecked
STGeneratorEfficiency
0.98
BOPLossasSTPowerFraction
0 fraction
BOPLossasFixedValue
0 kW
StreamReportGotoTop
Stream
AIR
CoolingWaterExit
VentSteamOutlet
FuelGasInlet
S0
S1
S10
S11
S12
S13
S14
S15
S16
S17
S18
S19
S2
S20
S21
S22
S23
S24
S25
S26
S27
S28
S29
S3
S30
S31
S32
S33
S34
S35
S36
S37
S38
From
AIR
CND1
DA1
FB1
HPST
FB1
HPST
FB1
FB1
HPST
FB1
IPST
FWH7
SP1
SP1
CND1
HPSH
CNDPMP
FWH1
FWH2
FWH3
SP4
FWH5
FWH6
FWH3
FWH2
DA1
IPSH
BFWPMP
FWH1
LPST
LPST
LPST
LPST
SP2
SP2
SP3
To
HX1
CND1
DA1
FB1
IPST
HPSH
FWH8
HPSH
V1
SP3
IPST
SP2
FWH8
FB1
FB1
CNDPMP
IPSH
FWH1
M1
FWH3
FWH5
FWH6
FWH3
DA1
FWH2
FWH1
BFWPMP
ECON
SP4
RCYPMP
CND1
FWH2
FWH1
FWH3
LPST
DA1
IPSH
Flow
kg/sec
677.7367
30957.5794
0
0
0
751.1221
24.4294
506.8741
506.8742
482.4448
455.5999
418.9822
506.8741
677.7367
0
349.3029
751.1221
349.3029
349.3029
407.6146
407.6146
506.8741
0
87.892
18.3933
40.4482
506.8757
751.1221
506.8741
58.3117
349.3029
22.0549
17.8634
18.3933
407.6131
11.3691
455.5999
Pressure
Temperature
kPa
C
101.0112
29.67
172.3689
38.2756
600
158.8375
1378.9499
15.56
0
-273.15
100.9001
973.35
4400
284.4524
26891.2002
396.85
26089.8413
540
3500
258.0455
3395.7
539.9989
700
322.0595
26891.2002
238.3826
101.0112
368.2873
101.0112
368.2873
13.7897
52.2641
100.9001
706.7551
1000
52.4006
980
80.4365
960.4
114.5936
941.192
140.8965
28000.0004
163.415
196.4763
187.3758
2156.0001
168.415
392
119.5936
196
86.1748
600
158.8375
100.9001
476.006
28000.0004
163.415
58.8
85.4365
13.7897
52.2641
200
187.2478
60
85.9539
400
259.3345
700
322.0595
700
322.0595
3500
258.0455
Enthalpy
kJ/kg
14.3682
153.7263
2755.4701
0
0
1129.701
2899.2793
2360.389
3291.2091
2854.9647
3541.8098
3105.9542
1034.5754
367.0504
367.0504
218.7253
789.5119
220.1393
337.4892
481.3441
593.3248
706.5607
2845.1414
712.954
502.1333
360.9614
670.426
509.6665
706.5607
357.7527
2456.5621
2844.6874
2645.1561
2983.7367
3105.9542
3105.9542
2854.9647
Quality
1
0
1
4
0.5
0
1
1
1
1
1
1
0
1
1
0
0
0
0
0
0
0
1
0
0
0
0
0
0
0
0.9413
1
0.9963
1
1
1
1
S39
S4
S40
S41
S42
S43
S44
S45
S46
S47
S48
S49
S5
S50
S51
S52
S53
S54
S55
S56
S6
S7
S8
S9
STACK
InternalPumpFlow
InternalPumpFlow
InternalPumpFlow
ExpansionLineEnd
ExpansionLineEnd
ExpansionLineEnd
SP3
HX1
IPST
MU1
M1
RCYPMP
V1
HPSPRY
IPSPRY
FWH5
SP4
SP4
ECON
FWH6
FWH7
LPST
FWH8
IPST
LPST
SRC1
HPSH
IPSH
ECON
FWH8
HX1
RCYPMP
BFWPMP
CNDPMP
LPST
IPST
HPST
FWH7
SP1
FWH6
CND1
FWH2
M1
HPST
FB1
FB1
DA1
IPSPRY
HPSPRY
HX1
FWH7
FWH6
FWH5
FWH7
LPST
GEN1
CND1
HPSPRY
IPSPRY
FB1
ECON
STACK
RCYPMP
BFWPMP
CNDPMP
LPST
IPST
HPST
26.8449
677.7367
36.6177
0
407.6146
58.3117
506.8742
506.8741
455.5998
407.6146
0
0
751.1221
506.8741
51.2743
0
24.4294
0
0
30957.5794
506.8741
455.5999
506.8741
506.8741
751.1221
58.3117
506.8741
349.3029
349.3029
418.9822
482.4448
3500
101.0112
2200
103.42
980
1000
25000
26353.3755
3430
941.192
28000.0004
28000.0004
100.9001
27440
3430
200.486
4400
0
0
172.3689
26353.3755
3430
26891.2002
26891.2002
100.9001
58.8
600
13.7897
13.7897
700
3500
258.0455
368.2873
477.0691
15.56
81.1748
85.5914
535.9015
440
439.9993
140.8965
163.415
163.415
449.4682
216.2035
241.3826
187.4849
256.0452
-273.15
-273.15
32
440
439.9993
266.85
257.0452
166.6958
85.4365
158.8375
52.2641
52.2641
322.0595
258.0455
2854.9647
367.0504
3414.6271
65.3825
340.5864
359.1395
3291.2091
2864.5053
3316.3568
593.3248
706.5607
706.5607
478.5371
935.245
1044.214
2845.1414
1115.3809
0
0
128.4762
2864.5053
3316.3568
1166.7414
1120.5523
160.3123
357.7527
670.426
218.7253
2446.5621
3105.9542
2854.9647
1
1
1
0
0
0
1
1
1
0
0
0
0
0
0
1
0
0.5
0.5
0
1
1
0
0
1
0
0
0
0.9371
1
1
Equipment/Ports
Flow
kg/sec
Pressure
kPa
Temperature
C
Enthalpy
kJ/kg
Quality
AIR[GAS]:GAS
Outlet
677.7367
101.0112
29.67
14.3682
BFWPMP[PUMP]:Pump
MainInlet
ControlValveOutlet
InternalPumpFlow
506.8757
506.8741
506.8741
600
28000.0004
600
158.8375
163.415
158.8375
670.426
706.5607
670.426
0
0
0
349.3029
349.3029
30957.5794
30957.5794
0
13.7897
13.7897
172.3689
172.3689
103.42
52.2641
52.2641
32
38.2756
15.56
2456.5621
218.7253
128.4762
153.7263
65.3825
0.9413
0
0
0
0
CNDPMP[PUMP]:Pump
MainInlet
ControlValveOutlet
InternalPumpFlow
349.3029
349.3029
349.3029
13.7897
1000
13.7897
52.2641
52.4006
52.2641
218.7253
220.1393
218.7253
0
0
0
DA1[DEAER]:Deaerator
MainSteamInlet
MainBoilerFeedWaterInlet
MainBoilerFeedWaterOutlet
AuxiliarySteamInlet
VentSteamOutlet
87.892
407.6146
506.8757
11.3691
0
2156.0001
941.192
600
700
600
168.415
140.8965
158.8375
322.0595
158.8375
712.954
593.3248
670.426
3105.9542
2755.4701
0
0
0
1
1
CND1[CONDSR]:Condenser
MainSteamInlet
MainExit
CoolingWaterInlet
CoolingWaterExit
AuxiliaryWaterInlet
ECON[ECON]:Economizer
GasInlet
GasOutlet
WaterInlet
WaterOutlet
751.1221
751.1221
506.8741
506.8741
100.9001
100.9001
26891.2002
26891.2002
476.006
449.4682
257.0452
266.85
509.6665
478.5371
1120.5523
1166.7414
0
0
0
0
FB1[FBOILR]:FossilBoiler
PrimaryAirInlet
SecondaryAirInlet
FlueGasOutlet
EvaporatorInlet
EvaporatorOutlet
SuperheaterInlet
SuperheaterOutlet
ReheaterInlet
ReheaterOutlet
FuelGasInlet
0
677.7367
751.1221
506.8741
506.8741
506.8741
506.8742
455.5998
455.5999
0
101.0112
101.0112
100.9001
26891.2002
26891.2002
26353.3755
26089.8413
3430
3395.7
1378.9499
368.2873
368.2873
973.35
266.85
396.85
440
540
439.9993
539.9989
15.56
367.0504
367.0504
1129.701
1166.7414
2360.389
2864.5053
3291.2091
3316.3568
3541.8098
0
1
1
0
0
1
1
1
1
1
4
FWH1[FWH]:FeedwaterHeater
ExtractionInlet
DrainOutlet
BoilerFeedWaterInlet
BoilerFeedWaterOutlet
DrainInlet
17.8634
58.3117
349.3029
349.3029
40.4482
60
58.8
1000
980
196
85.9539
85.4365
52.4006
80.4365
86.1748
2645.1561
357.7527
220.1393
337.4892
360.9614
0.9963
0
0
0
0
FWH2[FWH]:FeedwaterHeater
ExtractionInlet
DrainOutlet
BoilerFeedWaterInlet
BoilerFeedWaterOutlet
DrainInlet
22.0549
40.4482
407.6146
407.6146
18.3933
200
196
980
960.4
392
187.2478
86.1748
81.1748
114.5936
119.5936
2844.6874
360.9614
340.5864
481.3441
502.1333
1
0
0
0
0
FWH3[FWH]:FeedwaterHeater
ExtractionInlet
DrainOutlet
BoilerFeedWaterInlet
BoilerFeedWaterOutlet
DrainInlet
18.3933
18.3933
407.6146
407.6146
0
400
392
960.4
941.192
196.4763
259.3345
119.5936
114.5936
140.8965
187.3758
2983.7367
502.1333
481.3441
593.3248
2845.1414
1
0
0
0
1
FWH5[FWH]:FeedwaterHeater
ExtractionInlet
DrainOutlet
BoilerFeedWaterInlet
BoilerFeedWaterOutlet
0
0
407.6146
407.6146
200.486
196.4763
941.192
941.192
187.4849
187.3758
140.8965
140.8965
2845.1414
2845.1414
593.3248
593.3248
1
1
0
0
FWH6[FWH]:FeedwaterHeater
ExtractionInlet
DrainOutlet
BoilerFeedWaterInlet
BoilerFeedWaterOutlet
DrainInlet
36.6177
87.892
506.8741
506.8741
51.2743
2200
2156.0001
28000.0004
27440
3430
477.0691
168.415
163.415
216.2035
241.3826
3414.6271
712.954
706.5607
935.245
1044.214
1
0
0
0
0
FWH7[FWH]:FeedwaterHeater
ExtractionInlet
DrainOutlet
BoilerFeedWaterInlet
BoilerFeedWaterOutlet
DrainInlet
26.8449
51.2743
506.8741
506.8741
24.4294
3500
3430
27440
26891.2002
4400
258.0455
241.3826
216.2035
238.3826
256.0452
2854.9647
1044.214
935.245
1034.5754
1115.3809
1
0
0
0
0
FWH8[FWH]:FeedwaterHeater
ExtractionInlet
DrainOutlet
BoilerFeedWaterInlet
BoilerFeedWaterOutlet
24.4294
24.4294
506.8741
506.8741
4400
4400
26891.2002
26891.2002
284.4524
256.0452
238.3826
257.0452
2899.2793
1115.3809
1034.5754
1120.5523
1
0
0
0
GEN1[GENRTR]:Generator
Shaft1
-273.15
0.5
HPSH[SPHT]:Superheater
GasInlet
GasOutlet
SteamInlet
SteamOutlet
751.1221
751.1221
506.8741
506.8741
100.9001
100.9001
26891.2002
26353.3755
973.35
706.7551
396.85
440
1129.701
789.5119
2360.389
2864.5053
0
0
1
1
HPSPRY[TMIX]:TemperatureControlMixer
MainInlet
Outlet
ControlInlet
506.8741
506.8741
0
26353.3755
26353.3755
28000.0004
440
440
163.415
2864.5053
2864.5053
706.5607
1
1
0
HPST[ST]:SteamTurbine
SteamInlet
MainOutlet
SecondExtraction
ExpansionLineEnd
SecondShaft
506.8742
482.4448
24.4294
482.4448
0
25000
3500
4400
3500
0
535.9015
258.0455
284.4524
258.0455
-273.15
3291.2091
2854.9647
2899.2793
2854.9647
0
1
1
1
1
0.5
HX1[HEATX]:GeneralHeatExchanger
HotInlet
HotOutlet
ColdInlet
ColdOutlet
751.1221
751.1221
677.7367
677.7367
100.9001
100.9001
101.0112
101.0112
449.4682
166.6958
29.67
368.2873
478.5371
160.3123
14.3682
367.0504
0
1
1
1
IPSH[SPHT]:Superheater
GasInlet
GasOutlet
SteamInlet
SteamOutlet
751.1221
751.1221
455.5999
455.5999
100.9001
100.9001
3500
3430
706.7551
476.006
258.0455
439.9993
789.5119
509.6665
2854.9647
3316.3568
0
0
1
1
IPSPRY[TMIX]:TemperatureControlMixer
MainInlet
Outlet
ControlInlet
455.5999
455.5998
0
3430
3430
28000.0004
439.9993
439.9993
163.415
3316.3568
3316.3568
706.5607
1
1
0
IPST[ST]:SteamTurbine
SteamInlet
MainOutlet
FirstExtraction
ExpansionLineEnd
FirstShaft
SecondShaft
455.5999
418.9822
36.6177
418.9822
0
0
3395.7
700
2200
700
0
0
539.9989
322.0595
477.0691
322.0595
-273.15
-273.15
3541.8098
3105.9542
3414.6271
3105.9542
0
0
1
1
1
1
0.5
0.5
LPST[ST]:SteamTurbine
SteamInlet
MainOutlet
FirstExtraction
SecondExtraction
ThirdExtraction
FourthExtraction
ExpansionLineEnd
FirstShaft
SecondShaft
407.6131
349.3029
18.3933
0
22.0549
17.8634
349.3029
0
0
700
13.7897
400
200.486
200
60
13.7897
0
0
322.0595
52.2641
259.3345
187.4849
187.2478
85.9539
52.2641
-273.15
-273.15
3105.9542
2456.5621
2983.7367
2845.1414
2844.6874
2645.1561
2446.5621
0
0
1
0.9413
1
1
1
0.9963
0.9371
0.5
0.5
M1[MIXER]:Mixer
PrimaryInlet
Outlet
SecondaryInlet
349.3029
407.6146
58.3117
980
980
1000
80.4365
81.1748
85.5914
337.4892
340.5864
359.1395
0
0
0
103.42
15.56
65.3825
58.3117
58.3117
58.3117
58.8
1000
58.8
85.4365
85.5914
85.4365
357.7527
359.1395
357.7527
0
0
0
SP1[SPLITR]:Splitter
Inlet
PrimaryOutlet
SecondaryOutlet
677.7367
677.7367
0
101.0112
101.0112
101.0112
368.2873
368.2873
368.2873
367.0504
367.0504
367.0504
1
1
1
SP2[SPLITR]:Splitter
Inlet
PrimaryOutlet
SecondaryOutlet
418.9822
11.3691
407.6131
700
700
700
322.0595
322.0595
322.0595
3105.9542
3105.9542
3105.9542
1
1
1
SP3[SPLITR]:Splitter
Inlet
PrimaryOutlet
SecondaryOutlet
482.4448
26.8449
455.5999
3500
3500
3500
258.0455
258.0455
258.0455
2854.9647
2854.9647
2854.9647
1
1
1
SP4[SPLITR]:Splitter
Inlet
PrimaryOutlet
SecondaryOutlet
TertiaryOutlet
506.8741
0
0
506.8741
28000.0004
28000.0004
28000.0004
28000.0004
163.415
163.415
163.415
163.415
706.5607
706.5607
706.5607
706.5607
0
0
0
0
30957.5794
172.3689
32
128.4762
STACK[EXH]:EXH
Inlet
751.1221
100.9001
166.6958
160.3123
V1[PIPVLV]:Valve
Inlet
Outlet
506.8742
506.8742
26089.8413
25000
540
535.9015
3291.2091
3291.2091
1
1
MU1[MAKEUP]:Makeup
Outlet
RCYPMP[PUMP]:Pump
MainInlet
ControlValveOutlet
InternalPumpFlow
SRC1[SOURCE]:Source
Outlet
EquipmentID:AIRType:GASDescription:GASGotoTop
Flows
Pressure
Temperature
Enthalpy
Molecular
Weight
LowerHeating
Value
Oxygen,O2
Nitrogen,N2
Water,H2O
Carbon
Monoxide,CO
kg/sec
kPa
C
kJ/kg
Outlet
677.7367
101.0112
29.67
14.3682
28.6943
kJ/kg
fraction
fraction
fraction
0.2043
0.7615
0.0247
fraction
CarbonDioxide,
fraction
CO2
Methane,CH4 fraction
Hydrogen,H2 fraction
Argon,AR
fraction
Carbonyl
fraction
Sulfide,COS
Hydrogen
fraction
Sulfide,H2S
SulfurDioxide,
fraction
SO2
0.0003
0
0
0.0091
0
0
0
MainInputs
Data
Usedatafromthiswindow
FuelType
Air
UseSystemAmbientAir
UnChecked
AirRelativeHumidity
0.6
Calculation(flash)Method
Pressure-Temperature
Flowdoesnotaffectoverall
heatrate
HeatRateAdjustmentFlag
Flow
677.7367 kg/sec
Pressure
101.0112 kPa
Temperature
29.67 C
EquipmentID:BFWPMPType:PUMPDescription:PumpGotoTop
Control Internal
Valve
Pump
Outlet
Flow
506.8757 506.8741 506.8741
60028000.0004
600
158.8375
163.415 158.8375
670.426 706.5607
670.426
MainInlet
Flows
Pressure
Temperature
Enthalpy
VaporFraction
onaweight
basis
kg/sec
kPa
C
kJ/kg
fraction
MainInputs
CalculationMode
Design
PumpExitPressureMethodFlag
PumpExitPressure
DesiredPumpExitPressure
28500 kPa
CalculatedPumpExitPressure
VariableSpeedflag
28500 kPa
UnChecked
InputEfficiency
EfficiencyMethodFlag
DesiredIsentropicEfficiency
0.85
ActualIsentropicEfficiency
0.85
RatedFlowMethodFlag
RatedMassFlow
DesiredRatedMassFlowRate
0 kg/sec
RatedMassFlowRate
0 kg/sec
MinimumFlowFlagY/N
MinimumFlowRate
Checked
0 kg/sec
RatedHead
0m
RatedSpeed
3600
ControlMethodFlag
FixedControlValveOutletPressure
DesiredControlValveOutletPressure
28000 kPa
OutletPressure
28000 kPa
EfficiencyMethodSubFlag
HydraulicMethod
Checked
IncludePowerinBOP
Miscellaneous
Motor/GearboxLossFraction
0 fraction
RecirculationRate
CurrentValues
ActualIsentropicEfficiency
0.85
CalculatedPressureRatio
46.6667
CalculatedPumpExitPressure
28500 kPa
CalculatedP.Diff(PumpExit-ControlValveExit)
499.9995 kPa
DevelopedHead
3131.96 m
NetPositiveSuctionHeadAvailable
5.905E-06 m
RecirculationRate
PumpWork
-18316.46 kW
ShaftLosses
0 kW
Motor/GearboxLossFraction
0 fraction
InletSpecificVolume
0.0011 m^3/kg
RatedMassFlowRate
0 kg/sec
RatedVolumetricFlowRate
0 m^3/sec
RatedSpeed
3600
RatedHead
0m
ExergeticEfficiency(beta!)
0.9671
ShaftValues
InletShaftSpeed
3600
OutletShaftSpeed
3600
EquipmentID:CND1Type:CONDSRDescription:CondenserGotoTop
Flows
Pressure
Temperature
Enthalpy
VaporFraction
onaweight
basis
MainInputs
kg/sec
kPa
C
kJ/kg
fraction
Main
Cooling
Auxiliary
Cooling
Steam MainExit
Water
Water
WaterExit
Inlet
Inlet
Inlet
349.3029 349.302930957.579430957.5794
0
13.7897
13.7897 172.3689 172.3689
103.42
52.2641
52.2641
32
38.2756
15.56
2456.5621 218.7253 128.4762 153.7263
65.3825
0.9413
CalculationMode
Design
CondenserModellingMethod
DesiredPressure
DesiredExitPressure
13.7897 kPa
OutletPressure
13.7897 kPa
CoolingWaterMethodFlag
InputCoolingWaterData
CoolingWaterFlowRateMethodFlag
DemandCoolingWaterFlowRate
DesiredCoolingWaterFlowRate
30957.58 kg/sec
DesignHeatTransferCoefficientCalculationMethod
UserInputValuesforU
OverallHeatTransferCoefficient
2.85 kJ/sec-m^2-K
CoolingWaterPressureDropMethodFlag
NoPressureDrop
HEI9Inputs
HEICorrectionMethod
InputCorrectionFactor
DesignHEIC3Constant
0.69
TubeDiameterRangeIndicator
0.875,1.0inch(22.2,25.4mm)
HEIVelocityInsideTube
2.1336 m/sec
NumberofPasses
Miscellaneous
FractionofTubesBlocked
0 fraction
HeatTransferPerformanceFactor
HEICleanlinessFactor
0.85
ExitSubcooling
SteamInletPressureDropfractionflag
SteamInletPressureDrop
0C
Checked
0 fraction
MinimumAllowedPressure
1.7237 kPa
MaximumAllowedPressure
172.37 kPa
FoulingFactor
0 m^2-K-sec/kJ
DampingFactor
CurrentValues
SurfaceArea
CalculatedEffectiveness
CalculatedDuty
FixedCoolingWaterTemperatureRise
16196.46 m^2
0.3096
781682.9 kJ/sec
6.2756 C
ExergeticEfficiency(beta!)
ExitSubcooling
0C
SteamInletPressureDrop
0 fraction
CalculatedNTU
OverallHeatTransferCoefficient
CoolingWaterSpecificVolume
CoolingWaterAbsolutePressureDrop
CoolingWaterFractionalPressureDrop
0.3705
2.85 kJ/sec-m^2-K
0.001 m^3/kg
0 kPa
0
LogarithmicMeanTemperatureDifference
16.9332 C
TerminalTemperatureDifference
13.9886 C
CalculatedPinch(SaturationTemperature-CoolingWater
InletTemperature)
20.2646 C
NumberofTubesperPass
NumberofPasses
TotalNumberofTubes
TubeLength
0m
HEIC1Constant
HEIC2Constant
1.0719
HEIR1PressureDropConstant
HEIR2*RTPressureDropConstant
HEITubeEndLossPressureDropConstant
HEIWaterBoxInletPressureDropConstant
EquipmentID:CNDPMPType:PUMPDescription:PumpGotoTop
MainInlet
Flows
Pressure
Temperature
Enthalpy
VaporFraction
onaweight
basis
kg/sec
kPa
C
kJ/kg
349.3029
13.7897
52.2641
218.7253
fraction
Control Internal
Valve
Pump
Outlet
Flow
349.3029 349.3029
1000
13.7897
52.4006
52.2641
220.1393 218.7253
0
MainInputs
CalculationMode
Design
PumpExitPressureMethodFlag
PumpExitPressure
DesiredPumpExitPressure
1200 kPa
CalculatedPumpExitPressure
VariableSpeedflag
1200 kPa
UnChecked
InputEfficiency
EfficiencyMethodFlag
DesiredIsentropicEfficiency
0.85
ActualIsentropicEfficiency
0.85
RatedFlowMethodFlag
RatedMassFlow
DesiredRatedMassFlowRate
0 kg/sec
RatedMassFlowRate
0 kg/sec
MinimumFlowFlagY/N
Checked
MinimumFlowRate
0 kg/sec
RatedHead
0m
RatedSpeed
3600
ControlMethodFlag
FixedControlValveOutletPressure
DesiredControlValveOutletPressure
1000 kPa
OutletPressure
1000 kPa
EfficiencyMethodSubFlag
HydraulicMethod
Checked
IncludePowerinBOP
Miscellaneous
Motor/GearboxLossFraction
0 fraction
RecirculationRate
CurrentValues
ActualIsentropicEfficiency
0.85
CalculatedPressureRatio
72.5178
CalculatedPumpExitPressure
1200 kPa
CalculatedP.Diff(PumpExit-ControlValveExit)
199.9999 kPa
DevelopedHead
122.5555 m
NetPositiveSuctionHeadAvailable
-1.6984E-07 m
RecirculationRate
PumpWork
-493.9242 kW
ShaftLosses
0 kW
Motor/GearboxLossFraction
0 fraction
InletSpecificVolume
0.001 m^3/kg
RatedMassFlowRate
0 kg/sec
RatedVolumetricFlowRate
0 m^3/sec
RatedSpeed
3600
RatedHead
0m
ExergeticEfficiency(beta!)
0.9238
ShaftValues
InletShaftSpeed
3600
OutletShaftSpeed
3600
EquipmentID:DA1Type:DEAERDescription:DeaeratorGotoTop
Main
Steam
Inlet
Flows
Pressure
Temperature
Enthalpy
VaporFraction
onaweight
basis
kg/sec
kPa
C
kJ/kg
87.892
2156.0001
168.415
712.954
fraction
Main
Main
Boiler
Boiler Auxiliary
Vent
Feed
Feed
Steam
Steam
Water
Water
Inlet
Outlet
Inlet
Outlet
407.6146 506.8757
11.3691
0
941.192
600
700
600
140.8965 158.8375 322.0595 158.8375
593.3248
670.426 3105.9542 2755.4701
MainInputs
DAMethodFlag
2-ConstantPressure:Demand
PeggingSteamFlow
VentMethodFlag
SpecifiedfractionoftheinletBoiler
FeedWaterflow
DesiredVentFractionofBoilerFeedWater
0 fraction
VentFractionofBoilerFeedWater
0 fraction
PeggingSteamControlMethod
ControlAuxiliarySteamFlow
DesiredOperatingPressure
600 kPa
MainOutletPressure
600 kPa
DesiredBoilerFeedWaterSubcooling
0C
DemandFlowCalculations
UnChecked
UnChecked
UnChecked
EqualizeInletPressureFlag
DisableVentWarningFlag
CurrentValues
VentFractionofBoilerFeedWater
0 fraction
CurrentBoilerFeedWaterSubcooling
0C
ExergeticEfficiency(beta!)
0.9722
EquipmentID:ECONType:ECONDescription:EconomizerGotoTop
Water
Water
Inlet
Outlet
751.1221 506.8741 506.8741
100.900126891.200226891.2002
449.4682 257.0452
266.85
478.5371 1120.5523 1166.7414
GasInlet GasOutlet
Flows
kg/sec
Pressure
kPa
Temperature
C
Enthalpy
kJ/kg
VaporFraction
onaweight
fraction
basis
Molecular
Weight
LowerHeating
kJ/kg
Value
Oxygen,O2
fraction
Nitrogen,N2
fraction
Water,H2O
fraction
Carbon
fraction
Monoxide,CO
CarbonDioxide,
fraction
CO2
Methane,CH4 fraction
Hydrogen,H2 fraction
Argon,AR
fraction
Carbonyl
fraction
Sulfide,COS
Hydrogen
fraction
Sulfide,H2S
SulfurDioxide,
fraction
SO2
751.1221
100.9001
476.006
509.6665
0
29.5302
29.5302
0.0172
0.708
0.1139
0.0172
0.708
0.1139
0.15
0.15
0
0
0.0084
0
0
0.0084
0.0024
0.0024
MainInputs
CalculationMode
Design
EconomizerModelingMethod
WaterOutletTemperature
DesiredWaterOutletTemperature
266.85 C
Temperature
266.85 C
DesignUAMethod
SpecifyHTCoeff
OverallHeatTransferCoefficient
0.0454 kJ/sec-m^2-K
ConfigurationMethod
Cross-Counter-Current,1Tube
RowTotal,OuterFlowMixed,Inner
OnlyMixedbetweenPasses
NumberofHTXPasses
10
CheckforMinimumGasExitTemperature
UnChecked
PerformanceFactors
HeatTransferCoefficientPerformanceFactor
HotSidePressureLossPerformanceFactor
ColdSidePressureLossPerformanceFactor
Losses
HotsidePressureDropFractionFlag
Checked
Hotsidepressureloss
0 fraction
ColdsidePressureDropFractionFlag
Checked
Coldsidepressureloss
0 fraction
Energylossfraction
0 fraction
Foulingfactor
0 m^2-K-sec/kJ
CurrentValues
SurfaceArea
2643.978 m^2
CalculatedEffectiveness
0.1245
ExitSubcooling
107.2861 C
ApproachTemperature
209.1559 C
RadiantConvectiveLosses
0 kJ/sec
CalculatedDuty
23412.05 kJ/sec
CalculatedNTU
0.1361
OverallHeatTransferCoefficient
0.0454 kJ/sec-m^2-K
ExergeticEfficiency(beta!)
0.9875
Hotsidepressureloss
0 fraction
Coldsidepressureloss
0 fraction
Energylossfraction
0 fraction
Foulingfactor
0 m^2-K-sec/kJ
Limits
MinimumOverallHeatTransferCoefficient
0.0284 kJ/sec-m^2-K
MaximumOverallHeatTransferCoefficient
0.2839 kJ/sec-m^2-K
MinimumHotSidePressureDrop
0 fraction
MaximumHotSidePressureDrop
0.5 fraction
MinimumColdSidePressureDrop
0 fraction
MaximumColdSidePressureDrop
0.5 fraction
EquipmentID:FB1Type:FBOILRDescription:FossilBoilerGotoTop
Flows
kg/sec
Pressure
kPa
Temperature C
Enthalpy
kJ/kg
VaporFraction
onaweight
fraction
basis
Molecular
28.6943
29.5302
Weight
LowerHeating
kJ/kg
Value
Oxygen,O2
fraction
Nitrogen,N2
fraction
Water,H2O
fraction
Carbon
fraction
Monoxide,CO
Carbon
fraction
Dioxide,CO2
Methane,CH4 fraction
Hydrogen,H2 fraction
Argon,AR
fraction
Carbonyl
fraction
Sulfide,COS
Hydrogen
fraction
Sulfide,H2S
SulfurDioxide,
fraction
SO2
Flows
kg/sec
Pressure
kPa
Temperature
C
Enthalpy
kJ/kg
VaporFraction
onaweight
fraction
basis
Molecular
Weight
LowerHeating
kJ/kg
Value
Oxygen,O2
fraction
Nitrogen,N2
fraction
Water,H2O
fraction
Carbon
fraction
Monoxide,CO
CarbonDioxide,
fraction
CO2
Methane,CH4 fraction
Hydrogen,H2 fraction
Argon,AR
fraction
Carbonyl
fraction
Sulfide,COS
Hydrogen
fraction
Sulfide,H2S
SulfurDioxide,
fraction
SO2
0.2043
0.7615
0.0247
0.2043
0.7615
0.0247
0.0172
0.708
0.1139
0.0003
0.0003
0.15
0
0
0.0091
0
0
0.0091
0
0
0.0084
0.0024
Reheater FuelGas
Outlet
Inlet
455.5999
0
3395.7 1378.9499
539.9989
15.56
3541.8098
0
1
16.0425
47449.9983
0
0
0
0
0
1
0
0
0
0
0
MainInputs
CalculationMode
Design
WaterWallMethodFlag
ExitTemperature
DesiredWaterWallExitTemperature
396.85 C
WaterWallOutletTemperature
396.85 C
SuperheaterMethodFlag
ExitTemperature
DesiredSHExitTemperature
540 C
SuperheaterOutletTemperature
540 C
ReheaterMethodFlag
ExitTemperature
DesiredRHExitTemperature
540 C
ReheaterOutletTemperature
540 C
DesiredPressureDrop
DesiredPrimaryAirPressureDropFractionFlag
Checked
DesiredPrimaryAirPressureDrop
0.001 fraction
DesiredSecondaryAirPressureDropFractionFlag
Checked
DesiredSecondaryAirPressureDrop
0.001 fraction
DesiredRecycleGasPressureDropFractionFlag
Checked
DesiredRecycleGasPressureDrop
0.001 fraction
DesiredPulverizerPressureDropFractionFlag
Checked
DesiredPulverizerPressureDrop
0.001 fraction
DesiredFurnacePressureDropFractionFlag
Checked
DesiredFurnacePressureDrop
0.0001 fraction
DesiredWaterWallPressureDropFractionFlag
Checked
DesiredWaterWallPressureDrop
0 fraction
DesiredSuperheaterPressureDropFractionFlag
Checked
DesiredSuperheaterPressureDrop
0.01 fraction
DesiredReheaterPressureDropFractionFlag
Checked
DesiredReheaterPressureDrop
0.01 fraction
Geometry
FurnaceHeight/Depth
FurnaceWidth/Depth
FurnaceAperture/Depth
FurnaceColdAreaFraction
1 fraction
SHHeight/FurnaceDepth
1.25
RHHeight/FurnaceDepth
1.25
NumberofSuperheaterPanels
NumberofReheaterPanels
BoilerLoadMethodFlag
TotalFuelFlow
DesiredTotalFuelFlow
79.528 kg/sec
FuelFlow
79.528 kg/sec
FuelMixMethodFlag
FractionofTotalFuelHigher
HeatingValue(HHV)
BoilerFeedWaterFlowDamp.Factor
0.3
GasSettings
HydroCarbons
1 fraction
HC-Ratio
Hydrogen
0 fraction
Oxygen
0 fraction
Nitrogen
0 fraction
Argon
0 fraction
CarbonMonoxide
0 fraction
SulfurDioxide
0 fraction
H2O
0 fraction
CarbonylSulfide
0 fraction
CarbonDioxide
0 fraction
HydrogenSulfide
0 fraction
FuelGasLowerHeatingValue(LHV)
47450 kJ/kg
GasFuelInputFraction
0 fraction
CoalSettings
SolidFuelUlt.Anal.MethodFlag
AsReceived(ar)
SolidFuelA.R.Carbon
0.5809 fraction
SolidFuelA.R.Hydrogen
0.0426 fraction
SolidFuelA.R.Oxygen
0.1299 fraction
SolidFuelA.R.Nitrogen
0.0077 fraction
SolidFuelA.R.Sulfur
0.0245 fraction
CoalH.V.MethodFlag
HigherHeatingValue(HHV)ar
DesiredSolidFuelA.R.HigherHeatingValue(HHV)
5000 kcal/kg
SolidFuelA.R.HigherHeatingValue(HHV)
20934 kJ/kg
SolidFuelVolatileMatterFraction
0.4167 fraction
SolidFuelCarbonFraction
0.369 fraction
SolidFuelAshFraction
0.0714 fraction
SolidFuelWaterFraction
0.1429 fraction
PulverizerSpecificPowerCons.
0 kJ/kg
SolidFuelTemperature
293 K
CoalFuelInputFraction
1 fraction
OilSettings
OilH.V.MethodFlag
LowerHeatingValue(LHV)
DesiredOilLowerHeatingValue(LHV)
43960 kJ/kg
OilLowerHeatingValue(LHV)
43960 kJ/kg
OilCarbonbyWeight
0.8719 fraction
OilHydrogenbyWeight
0.1258 fraction
OilOxygenbyWeight
0 fraction
OilNitrogenbyWeight
6E-05 fraction
OilSulfurbyWeight
0.0022 fraction
OilAshbyWeight
0 fraction
OilWaterbyWeight
0 fraction
OilDensity(API)
35 kg/m^3
OilTemperature
19.85 C
OilPreheaterTemperature
149.85 C
OilFuelInputFraction
0 fraction
Combustion
CombustionMethodFlag
FractionExcessAir
DesiredExcessAirFraction
0.1 fraction
ExcessAirFraction
0.1 fraction
DesiredExhaustGasTemperature
973.35 C
FlueGasTemperature
973.35 C
Pri.Air/UnitWeightGas
0 fraction
Pri.Air/UnitWeightSolidFuel
0 fraction
Pri.Air/UnitWeightOil
DisableMinimumFlueGasTemperatureWarning
0 fraction
UnChecked
AshInputs
BottomAshTemperature
BottomAshFraction
EconomizerAshTemperature
Econ.Hop.AshFraction
PCLAshTemperature
Part.Coll.AshFraction
1099.85 C
0.35 fraction
199.85 C
0.05 fraction
124.85 C
0.6 fraction
SorbentInputs
SorbentTemperature
20 C
SorbentCaCO3Fraction
1 fraction
SorbentMgCO3Fraction
0 fraction
SorbentCa(OH)2Fraction
0 fraction
SorbentWaterFraction
0 fraction
SorbentInertMaterialFraction
0 fraction
CaCO3OxidationEffectiveness
0.9
MgCO3OxidationEffectiveness
0.999
SO2ConversionEffectiveness
CatoSMolarRatio
Radiation
FurnaceWallTemperatureWeight.
FurnaceGasTemperatureWeighting
0.5
0.95
SHWallTemperatureWeighting
0.5
SHGasTemperatureWeighting
0.97
RHWallTemperatureWeighting
0.5
RHGasTemperatureWeighting
0.98
FlameEnvelope/FurnaceSurfaceArea
Emissivities
CoalParticleEmissivity
0.2
WallEmissivity
0.8
OilDropletEmissivity
0.2
SootEmissivity
0.01
HeatTransfer
AshThermalConductivity
147.1 kJ/sec-m-K
FurnaceWallAshThick.
0m
SHPanelAshThickness
0m
RHPanelAshThickness
0m
FurnaceConvectiveHeatTransferCoefficient
0.0111 kJ/sec-m^2-K
SHConvectiveHeatTransferCoefficient
0.0222 kJ/sec-m^2-K
RHConvectiveHeatTransferCoefficient
0.0277 kJ/sec-m^2-K
AreaChange
FurnaceAreaCorrectionFactor
SHAreaCorrectionFactor
RHAreaCorrectionFactor
PerformanceFactors
FurnaceHTPerformanceFactor
SHRad.HTPerformanceFactor
RHRad.HTPerformanceFactor
PressureDropPerformanceFactor
Losses
UnburntCarbonMethodFlag
UnburntCarboninAsh
FractionofCarbontoAsh
0.01 fraction
UnburntCarbonH.V.
UBCCarbonasCO
Rad.HeatLossFraction
33262 kJ/kg
0 fraction
0.01 fraction
CurrentValues
TotalDutyTransferredtoH2OSide
Duty@FurnaceWalls
924030.5 kJ/sec
605029 kJ/sec
Duty@RadiantSH
216285.1 kJ/sec
Duty@RadiantRH
102716.4 kJ/sec
RadiantHeatLoss
18123.9 kJ/sec
TotalFuelFlow
79.528 kg/sec
O2FractioninDryExhaustGas
0.0195 fraction
O2FractioninWetExhaustGas
HigherHeatingValue(HHV)HeatLoad
LowerHeatingValue(LHV)HeatLoad
CurrentAdiab.FlameTemperature
0.0172 fraction
1664839 kJ/sec
1563107 kJ/sec
1885.026 C
CurrentBoilerEfficiency
0.5098
CurrentReducedBoilerEfficiency
0.4416
CurrentReducedFiringDensity
0.2609
CurrentReducedSinkTemperature
0.3193
CurrentCalculatedHeatReleaseRate
138.4388 kW/m^2
CurrentStationaryHeatReleaseRate
149.8293 kW/m^2
FurnaceConvectiveHeatTransferCoefficient
0.0111 kJ/sec-m^2-K
FurnaceEquivalentOverallHeatTransferCoefficient
0.0897 kJ/sec-m^2-K
FurnaceHTfromConv.
0.0853 fraction
FurnaceHTfromRadiation
0.9147 fraction
FurnaceWallSurfaceArea
7165.476 m^2
SHEquivalentOverallHeatTransferCoefficient
0.1011 kJ/sec-m^2-K
SHHTfromConvection
0.1484 fraction
SHHTfromRadiation
SHPanelSurfaceArea
0.8516 fraction
2796.587 m^2
RHEquivalentOverallHeatTransferCoefficient
0.1023 kJ/sec-m^2-K
RHHTfromConvection
0.1798 fraction
RHHTfromRadiation
RHPanelSurfaceArea
0.8202 fraction
1328.895 m^2
Geometry
FurnaceHeight/Depth
FurnaceWidth/Depth
FurnaceAperture/Depth
FurnaceColdAreaFraction
1 fraction
SHHeight/FurnaceDepth
1.25
RHHeight/FurnaceDepth
1.25
NumberofSuperheaterPanels
NumberofReheaterPanels
FurnaceWallSurfaceArea
7165.476 m^2
FurnaceWallHeight
79.8045 m
FurnaceWallWidth
19.9511 m
FurnaceWallDepth
19.9511 m
SHPanelSurfaceArea
2796.587 m^2
SHPanelSurfaceHeight
24.9389 m
SHPanelSurfaceWidth
56.0688 m
RHPanelSurfaceArea
1328.895 m^2
RHPanelSurfaceHeight
24.9389 m
RHPanelSurfaceWidth
26.643 m
DesiredPressureDrop
DesiredPrimaryAirPressureDrop
0.001 fraction
DesiredSecondaryAirPressureDrop
0.001 fraction
DesiredRecycleGasPressureDrop
0.001 fraction
DesiredPulverizerPressureDrop
0.001 fraction
DesiredFurnacePressureDrop
0.0001 fraction
DesiredWaterWallPressureDrop
0 fraction
DesiredSuperheaterPressureDrop
0.01 fraction
DesiredReheaterPressureDrop
0.01 fraction
Limits
MinimumColdSidePressureDrop
0 fraction
MaximumColdSidePressureDrop
0.5 fraction
MinimumOverallHeatTransferCoefficient
0.0011 kJ/sec-m^2-K
MaximumOverallHeatTransferCoefficient
0.2839 kJ/sec-m^2-K
MinimumHotSidePressureDrop
0 fraction
MaximumHotSidePressureDrop
0.5 fraction
EquipmentID:FWH1Type:FWHDescription:FeedwaterHeaterGotoTop
Extraction
Inlet
Flows
Pressure
Temperature
Enthalpy
VaporFraction
onaweight
basis
kg/sec
kPa
C
kJ/kg
fraction
Drain
Outlet
17.8634
60
85.9539
2645.1561
58.3117
58.8
85.4365
357.7527
0.9963
Boiler
Boiler
Feed
Feed
Drain
Water
Water
Inlet
Inlet
Outlet
349.3029 349.3029
40.4482
1000
980
196
52.4006
80.4365
86.1748
220.1393 337.4892 360.9614
0
MainInputs
CalculationMode
Design
CondensingSectionHeatTransferCoefficient.
DesignMethod
3.4 kJ/sec-m^2-K
TerminalTemperatureDifference
DesiredTerminalTemperatureDifference
5C
TerminalTemperatureDifference
5C
UseDrainCooler
NoDrainCooling
UnChecked
BypassDesuperheatingZone
SteamSectionHeatTransferCoefficient.
0.7 kJ/sec-m^2-K
DemandFlowDampingFactor
0.15
PerformanceFactors
HeatTransferCoefficientPerformanceFactor
HotSidePressureLossPerformanceFactor
ColdSidePressureLossPerformanceFactor
Losses
HotsidePressureDropFractionFlag
Checked
Hotsidepressureloss
0.02 fraction
ColdsidePressureDropFractionFlag
Checked
Coldsidepressureloss
0.02 fraction
OutletDrainPressureDropFractionFlag
Checked
OutletDrainPressureDrop
0 fraction
InletValvePressureDropFractionFlag
InletValvePressureDrop
Checked
0 fraction
Energylossfraction
0 fraction
Foulingfactor
0 m^2-K-sec/kJ
CurrentValues
CalculatedDuty
CalculatedHeatLosses
TotalSurfaceArea
40990.66 kJ/sec
0 kJ/sec
811.2085 m^2
TerminalTemperatureDifference
5C
DrainCoolerApproach
5C
ExergeticEfficiency(beta!)
0.785
SteamSectionHeatTransferCoefficient.
0.7 kJ/sec-m^2-K
CondensingSectionHeatTransferCoefficient.
3.4 kJ/sec-m^2-K
DrainCoolerHeatTransferCoefficient.
SteamSectionEffectiveness.
CondensingSectionEffectiveness.
2 kJ/sec-m^2-K
0
0.8482
DrainCoolerEffectiveness
DesuperheatingSectionArea
0 m^2
CondensingSectionArea
811.2085 m^2
DrainCoolerSectionArea
0 m^2
OutletDrainPressureDrop
0 fraction
Hotsidepressureloss
0.02 fraction
InletValvePressureDrop
0 fraction
Coldsidepressureloss
0.02 fraction
NumberofHTXPasses
Energylossfraction
0 fraction
Foulingfactor
0 m^2-K-sec/kJ
Limits
MinimumOverallHeatTransferCoefficient
0.0284 kJ/sec-m^2-K
MaximumOverallHeatTransferCoefficient
4.2587 kJ/sec-m^2-K
MinimumHotSidePressureDrop
0 fraction
MaximumHotSidePressureDrop
0.5 fraction
MinimumColdSidePressureDrop
0 fraction
MaximumColdSidePressureDrop
0.5 fraction
EquipmentID:FWH2Type:FWHDescription:FeedwaterHeaterGotoTop
Extraction
Inlet
Flows
Pressure
Temperature
Enthalpy
VaporFraction
onaweight
basis
kg/sec
kPa
C
kJ/kg
Drain
Outlet
22.0549
200
187.2478
2844.6874
40.4482
196
86.1748
360.9614
fraction
Boiler
Boiler
Feed
Feed
Drain
Water
Water
Inlet
Inlet
Outlet
407.6146 407.6146
18.3933
980
960.4
392
81.1748 114.5936 119.5936
340.5864 481.3441 502.1333
0
MainInputs
CalculationMode
Design
CondensingSectionHeatTransferCoefficient.
DesignMethod
3.4 kJ/sec-m^2-K
TerminalTemperatureDifference
DesiredTerminalTemperatureDifference
5C
TerminalTemperatureDifference
5C
UseDrainCooler
DrainCoolingApproach
Temperature
DrainCoolerApproach
5C
DrainCoolerHeatTransferCoefficient.
2 kJ/sec-m^2-K
BypassDesuperheatingZone
UnChecked
SteamSectionHeatTransferCoefficient.
0.7 kJ/sec-m^2-K
DemandFlowDampingFactor
0.5
PerformanceFactors
HeatTransferCoefficientPerformanceFactor
HotSidePressureLossPerformanceFactor
ColdSidePressureLossPerformanceFactor
Losses
HotsidePressureDropFractionFlag
Checked
Hotsidepressureloss
0.02 fraction
ColdsidePressureDropFractionFlag
Checked
Coldsidepressureloss
0.02 fraction
OutletDrainPressureDropFractionFlag
Checked
OutletDrainPressureDrop
0 fraction
InletValvePressureDropFractionFlag
Checked
InletValvePressureDrop
0 fraction
Energylossfraction
0 fraction
Foulingfactor
0 m^2-K-sec/kJ
CurrentValues
CalculatedDuty
57374.93 kJ/sec
CalculatedHeatLosses
0 kJ/sec
TotalSurfaceArea
1173.575 m^2
TerminalTemperatureDifference
5C
DrainCoolerApproach
5C
ExergeticEfficiency(beta!)
0.8768
SteamSectionHeatTransferCoefficient.
0.7 kJ/sec-m^2-K
CondensingSectionHeatTransferCoefficient.
3.4 kJ/sec-m^2-K
DrainCoolerHeatTransferCoefficient.
2 kJ/sec-m^2-K
SteamSectionEffectiveness.
0.9088
CondensingSectionEffectiveness.
0.8067
DrainCoolerEffectiveness
0.8699
DesuperheatingSectionArea
158.17 m^2
CondensingSectionArea
830.6842 m^2
DrainCoolerSectionArea
184.7207 m^2
OutletDrainPressureDrop
0 fraction
Hotsidepressureloss
0.02 fraction
InletValvePressureDrop
0 fraction
Coldsidepressureloss
0.02 fraction
NumberofHTXPasses
Energylossfraction
0 fraction
Foulingfactor
0 m^2-K-sec/kJ
Limits
MinimumOverallHeatTransferCoefficient
0.0284 kJ/sec-m^2-K
MaximumOverallHeatTransferCoefficient
4.2587 kJ/sec-m^2-K
MinimumHotSidePressureDrop
0 fraction
MaximumHotSidePressureDrop
0.5 fraction
MinimumColdSidePressureDrop
0 fraction
MaximumColdSidePressureDrop
0.5 fraction
EquipmentID:FWH3Type:FWHDescription:FeedwaterHeaterGotoTop
Extraction
Inlet
Drain
Outlet
Boiler
Feed
Water
Inlet
Boiler
Feed
Water
Outlet
Drain
Inlet
Flows
Pressure
Temperature
Enthalpy
VaporFraction
onaweight
basis
kg/sec
kPa
C
kJ/kg
18.3933
400
259.3345
2983.7367
18.3933
392
119.5936
502.1333
407.6146
960.4
114.5936
481.3441
fraction
407.6146
0
941.192 196.4763
140.8965 187.3758
593.3248 2845.1414
0
MainInputs
CalculationMode
Design
CondensingSectionHeatTransferCoefficient.
DesignMethod
3.4 kJ/sec-m^2-K
TerminalTemperatureDifference
DesiredTerminalTemperatureDifference
2C
TerminalTemperatureDifference
2C
UseDrainCooler
DrainCoolingApproach
Temperature
DrainCoolerApproach
5C
DrainCoolerHeatTransferCoefficient.
2 kJ/sec-m^2-K
BypassDesuperheatingZone
UnChecked
SteamSectionHeatTransferCoefficient.
0.7 kJ/sec-m^2-K
DemandFlowDampingFactor
0.8
PerformanceFactors
HeatTransferCoefficientPerformanceFactor
HotSidePressureLossPerformanceFactor
ColdSidePressureLossPerformanceFactor
Losses
HotsidePressureDropFractionFlag
Checked
Hotsidepressureloss
0.02 fraction
ColdsidePressureDropFractionFlag
Checked
Coldsidepressureloss
0.02 fraction
OutletDrainPressureDropFractionFlag
Checked
OutletDrainPressureDrop
0 fraction
InletValvePressureDropFractionFlag
InletValvePressureDrop
Checked
0 fraction
Energylossfraction
0 fraction
Foulingfactor
0 m^2-K-sec/kJ
CurrentValues
CalculatedDuty
CalculatedHeatLosses
TotalSurfaceArea
TerminalTemperatureDifference
DrainCoolerApproach
ExergeticEfficiency(beta!)
45644.96 kJ/sec
0 kJ/sec
1163.127 m^2
2C
5C
0.9479
SteamSectionHeatTransferCoefficient.
0.7 kJ/sec-m^2-K
CondensingSectionHeatTransferCoefficient.
3.4 kJ/sec-m^2-K
DrainCoolerHeatTransferCoefficient.
2 kJ/sec-m^2-K
SteamSectionEffectiveness.
0.9619
CondensingSectionEffectiveness.
0.8311
DrainCoolerEffectiveness
0.8233
DesuperheatingSectionArea
185.3095 m^2
CondensingSectionArea
908.1313 m^2
DrainCoolerSectionArea
69.6858 m^2
OutletDrainPressureDrop
0 fraction
Hotsidepressureloss
0.02 fraction
InletValvePressureDrop
0 fraction
Coldsidepressureloss
0.02 fraction
NumberofHTXPasses
Energylossfraction
0 fraction
Foulingfactor
0 m^2-K-sec/kJ
Limits
MinimumOverallHeatTransferCoefficient
0.0284 kJ/sec-m^2-K
MaximumOverallHeatTransferCoefficient
4.2587 kJ/sec-m^2-K
MinimumHotSidePressureDrop
0 fraction
MaximumHotSidePressureDrop
0.5 fraction
MinimumColdSidePressureDrop
0 fraction
MaximumColdSidePressureDrop
0.5 fraction
EquipmentID:FWH5Type:FWHDescription:FeedwaterHeaterGotoTop
Extraction
Inlet
Flows
Pressure
Temperature
Enthalpy
VaporFraction
onaweight
basis
kg/sec
kPa
C
kJ/kg
Drain
Outlet
0
0
200.486 196.4763
187.4849 187.3758
2845.1414 2845.1414
fraction
Boiler
Boiler
Feed
Feed
Water
Water
Inlet
Outlet
407.6146 407.6146
941.192
941.192
140.8965 140.8965
593.3248 593.3248
0
MainInputs
CalculationMode
Design
CondensingSectionHeatTransferCoefficient.
DesignMethod
3.4 kJ/sec-m^2-K
TerminalTemperatureDifference
DesiredTerminalTemperatureDifference
-1 C
TerminalTemperatureDifference
0C
UseDrainCooler
DrainCoolingApproach
Temperature
DrainCoolerApproach
5C
DrainCoolerHeatTransferCoefficient.
2 kJ/sec-m^2-K
BypassDesuperheatingZone
SteamSectionHeatTransferCoefficient.
UnChecked
0.7 kJ/sec-m^2-K
DemandFlowDampingFactor
0.8
PerformanceFactors
HeatTransferCoefficientPerformanceFactor
HotSidePressureLossPerformanceFactor
ColdSidePressureLossPerformanceFactor
Losses
HotsidePressureDropFractionFlag
Checked
Hotsidepressureloss
0.02 fraction
ColdsidePressureDropFractionFlag
Checked
Coldsidepressureloss
0.02 fraction
OutletDrainPressureDropFractionFlag
Checked
OutletDrainPressureDrop
0 fraction
InletValvePressureDropFractionFlag
InletValvePressureDrop
Checked
0 fraction
Energylossfraction
0 fraction
Foulingfactor
0 m^2-K-sec/kJ
CurrentValues
CalculatedDuty
0 kJ/sec
CalculatedHeatLosses
0 kJ/sec
TotalSurfaceArea
0 m^2
TerminalTemperatureDifference
0C
DrainCoolerApproach
5C
ExergeticEfficiency(beta!)
SteamSectionHeatTransferCoefficient.
0.7 kJ/sec-m^2-K
CondensingSectionHeatTransferCoefficient.
3.4 kJ/sec-m^2-K
DrainCoolerHeatTransferCoefficient.
2 kJ/sec-m^2-K
SteamSectionEffectiveness.
CondensingSectionEffectiveness.
DrainCoolerEffectiveness
DesuperheatingSectionArea
0 m^2
CondensingSectionArea
0 m^2
DrainCoolerSectionArea
0 m^2
OutletDrainPressureDrop
0 fraction
Hotsidepressureloss
InletValvePressureDrop
Coldsidepressureloss
0.02 fraction
0 fraction
0.02 fraction
NumberofHTXPasses
Energylossfraction
0 fraction
Foulingfactor
0 m^2-K-sec/kJ
Limits
MinimumOverallHeatTransferCoefficient
0.0284 kJ/sec-m^2-K
MaximumOverallHeatTransferCoefficient
4.2587 kJ/sec-m^2-K
MinimumHotSidePressureDrop
0 fraction
MaximumHotSidePressureDrop
0.5 fraction
MinimumColdSidePressureDrop
0 fraction
MaximumColdSidePressureDrop
0.5 fraction
EquipmentID:FWH6Type:FWHDescription:FeedwaterHeaterGotoTop
Extraction
Inlet
Flows
Pressure
Temperature
Enthalpy
VaporFraction
onaweight
basis
kg/sec
kPa
C
kJ/kg
36.6177
2200
477.0691
3414.6271
fraction
Boiler
Boiler
Feed
Feed
Drain
Water
Water
Inlet
Inlet
Outlet
87.892 506.8741 506.8741
51.2743
2156.000128000.0004
27440
3430
168.415
163.415 216.2035 241.3826
712.954 706.5607
935.245 1044.214
Drain
Outlet
MainInputs
CalculationMode
Design
CondensingSectionHeatTransferCoefficient.
DesignMethod
3.4 kJ/sec-m^2-K
TerminalTemperatureDifference
DesiredTerminalTemperatureDifference
0C
TerminalTemperatureDifference
0C
UseDrainCooler
DrainCoolingApproach
Temperature
DrainCoolerApproach
5C
DrainCoolerHeatTransferCoefficient.
2 kJ/sec-m^2-K
BypassDesuperheatingZone
UnChecked
SteamSectionHeatTransferCoefficient.
0.7 kJ/sec-m^2-K
DemandFlowDampingFactor
0.8
PerformanceFactors
HeatTransferCoefficientPerformanceFactor
HotSidePressureLossPerformanceFactor
ColdSidePressureLossPerformanceFactor
Losses
HotsidePressureDropFractionFlag
Checked
Hotsidepressureloss
0.02 fraction
ColdsidePressureDropFractionFlag
Checked
Coldsidepressureloss
0.02 fraction
OutletDrainPressureDropFractionFlag
Checked
OutletDrainPressureDrop
0 fraction
InletValvePressureDropFractionFlag
InletValvePressureDrop
Checked
0 fraction
Energylossfraction
0 fraction
Foulingfactor
0 m^2-K-sec/kJ
CurrentValues
CalculatedDuty
115914.1 kJ/sec
CalculatedHeatLosses
0 kJ/sec
TotalSurfaceArea
1851.763 m^2
TerminalTemperatureDifference
0C
DrainCoolerApproach
5C
ExergeticEfficiency(beta!)
0.9449
SteamSectionHeatTransferCoefficient.
0.7 kJ/sec-m^2-K
CondensingSectionHeatTransferCoefficient.
3.4 kJ/sec-m^2-K
DrainCoolerHeatTransferCoefficient.
2 kJ/sec-m^2-K
SteamSectionEffectiveness.
0.9627
CondensingSectionEffectiveness.
0.756
DrainCoolerEffectiveness
0.9053
DesuperheatingSectionArea
418.1913 m^2
CondensingSectionArea
912.0175 m^2
DrainCoolerSectionArea
521.5546 m^2
OutletDrainPressureDrop
0 fraction
Hotsidepressureloss
0.02 fraction
InletValvePressureDrop
0 fraction
Coldsidepressureloss
0.02 fraction
NumberofHTXPasses
Energylossfraction
0 fraction
Foulingfactor
0 m^2-K-sec/kJ
Limits
MinimumOverallHeatTransferCoefficient
0.0284 kJ/sec-m^2-K
MaximumOverallHeatTransferCoefficient
4.2587 kJ/sec-m^2-K
MinimumHotSidePressureDrop
0 fraction
MaximumHotSidePressureDrop
0.5 fraction
MinimumColdSidePressureDrop
0 fraction
MaximumColdSidePressureDrop
0.5 fraction
EquipmentID:FWH7Type:FWHDescription:FeedwaterHeaterGotoTop
Extraction
Inlet
Flows
Pressure
Temperature
Enthalpy
VaporFraction
onaweight
basis
kg/sec
kPa
C
kJ/kg
Drain
Outlet
26.8449
3500
258.0455
2854.9647
51.2743
3430
241.3826
1044.214
fraction
Boiler
Boiler
Feed
Feed
Drain
Water
Water
Inlet
Inlet
Outlet
506.8741 506.8741
24.4294
2744026891.2002
4400
216.2035 238.3826 256.0452
935.245 1034.5754 1115.3809
0
MainInputs
CalculationMode
CondensingSectionHeatTransferCoefficient.
DesignMethod
Design
3.4 kJ/sec-m^2-K
TerminalTemperatureDifference
DesiredTerminalTemperatureDifference
3C
TerminalTemperatureDifference
3C
UseDrainCooler
NoDrainCooling
BypassDesuperheatingZone
UnChecked
SteamSectionHeatTransferCoefficient.
0.7 kJ/sec-m^2-K
DemandFlowDampingFactor
0.5
PerformanceFactors
HeatTransferCoefficientPerformanceFactor
HotSidePressureLossPerformanceFactor
ColdSidePressureLossPerformanceFactor
Losses
HotsidePressureDropFractionFlag
Checked
Hotsidepressureloss
0.02 fraction
ColdsidePressureDropFractionFlag
Checked
Coldsidepressureloss
0.02 fraction
OutletDrainPressureDropFractionFlag
Checked
OutletDrainPressureDrop
0 fraction
InletValvePressureDropFractionFlag
InletValvePressureDrop
Checked
0 fraction
Energylossfraction
0 fraction
Foulingfactor
0 m^2-K-sec/kJ
CurrentValues
CalculatedDuty
CalculatedHeatLosses
TotalSurfaceArea
50348.02 kJ/sec
0 kJ/sec
1500.904 m^2
TerminalTemperatureDifference
3C
DrainCoolerApproach
5C
ExergeticEfficiency(beta!)
0.9917
SteamSectionHeatTransferCoefficient.
0.7 kJ/sec-m^2-K
CondensingSectionHeatTransferCoefficient.
3.4 kJ/sec-m^2-K
DrainCoolerHeatTransferCoefficient.
2 kJ/sec-m^2-K
SteamSectionEffectiveness.
0.8115
CondensingSectionEffectiveness.
0.8518
DrainCoolerEffectiveness
DesuperheatingSectionArea
221.8153 m^2
CondensingSectionArea
1279.088 m^2
DrainCoolerSectionArea
0 m^2
OutletDrainPressureDrop
0 fraction
Hotsidepressureloss
InletValvePressureDrop
Coldsidepressureloss
0.02 fraction
0 fraction
0.02 fraction
NumberofHTXPasses
Energylossfraction
0 fraction
Foulingfactor
0 m^2-K-sec/kJ
Limits
MinimumOverallHeatTransferCoefficient
0.0284 kJ/sec-m^2-K
MaximumOverallHeatTransferCoefficient
4.2587 kJ/sec-m^2-K
MinimumHotSidePressureDrop
0 fraction
MaximumHotSidePressureDrop
0.5 fraction
MinimumColdSidePressureDrop
0 fraction
MaximumColdSidePressureDrop
0.5 fraction
EquipmentID:FWH8Type:FWHDescription:FeedwaterHeaterGotoTop
Extraction
Inlet
Flows
Pressure
Temperature
Enthalpy
VaporFraction
onaweight
basis
kg/sec
kPa
C
kJ/kg
24.4294
4400
284.4524
2899.2793
fraction
Boiler
Boiler
Feed
Feed
Water
Water
Inlet
Outlet
24.4294 506.8741 506.8741
440026891.200226891.2002
256.0452 238.3826 257.0452
1115.3809 1034.5754 1120.5523
Drain
Outlet
MainInputs
CalculationMode
Design
CondensingSectionHeatTransferCoefficient.
DesignMethod
3.4 kJ/sec-m^2-K
TerminalTemperatureDifference
DesiredTerminalTemperatureDifference
-1 C
TerminalTemperatureDifference
-1 C
UseDrainCooler
NoDrainCooling
UnChecked
BypassDesuperheatingZone
SteamSectionHeatTransferCoefficient.
0.7 kJ/sec-m^2-K
DemandFlowDampingFactor
0.5
PerformanceFactors
HeatTransferCoefficientPerformanceFactor
HotSidePressureLossPerformanceFactor
ColdSidePressureLossPerformanceFactor
Losses
HotsidePressureDropFractionFlag
Checked
Hotsidepressureloss
0 fraction
ColdsidePressureDropFractionFlag
Checked
Coldsidepressureloss
0 fraction
OutletDrainPressureDropFractionFlag
Checked
OutletDrainPressureDrop
0 fraction
InletValvePressureDropFractionFlag
InletValvePressureDrop
Checked
0 fraction
Energylossfraction
0 fraction
Foulingfactor
0 m^2-K-sec/kJ
CurrentValues
CalculatedDuty
43579.49 kJ/sec
CalculatedHeatLosses
0 kJ/sec
TotalSurfaceArea
4969.972 m^2
TerminalTemperatureDifference
-1 C
DrainCoolerApproach
5C
ExergeticEfficiency(beta!)
0.9971
SteamSectionHeatTransferCoefficient.
0.7 kJ/sec-m^2-K
CondensingSectionHeatTransferCoefficient.
3.4 kJ/sec-m^2-K
DrainCoolerHeatTransferCoefficient.
2 kJ/sec-m^2-K
SteamSectionEffectiveness.
0.9985
CondensingSectionEffectiveness.
0.9976
DrainCoolerEffectiveness
DesuperheatingSectionArea
833.3336 m^2
CondensingSectionArea
4136.638 m^2
DrainCoolerSectionArea
0 m^2
OutletDrainPressureDrop
0 fraction
Hotsidepressureloss
0 fraction
InletValvePressureDrop
0 fraction
Coldsidepressureloss
0 fraction
NumberofHTXPasses
Energylossfraction
0 fraction
Foulingfactor
0 m^2-K-sec/kJ
Limits
MinimumOverallHeatTransferCoefficient
0.0284 kJ/sec-m^2-K
MaximumOverallHeatTransferCoefficient
4.2587 kJ/sec-m^2-K
MinimumHotSidePressureDrop
0 fraction
MaximumHotSidePressureDrop
0.5 fraction
MinimumColdSidePressureDrop
0 fraction
MaximumColdSidePressureDrop
0.5 fraction
EquipmentID:GEN1Type:GENRTRDescription:GeneratorGotoTop
MainInputs
CalculationMode
GeneratorRPM
Design
3000
GeneratorRating(kVA)
710000
RatingCoolantPressure
515.04 kPa
Connections
Margin
MarginEquationMforSTcomponents
MarginEquationMforGTcomponents
MarginEquationBforSTcomponents
MarginEquationBforGTcomponents
RatingforSTcomponents
1 kW
RatingforGTcomponents
1 kW
GeneratorEfficiencyMethodFlag
SpecifiedGeneratorEfficiency
DesiredOverallGeneratorEfficiency
0.99
OverallGeneratorEfficiency
0.99
PowerFactor
0.8
MarginonkVAWarning
UseSystemAmbientAir
UnChecked
CoolantPressure
515.04 kPa
CurrentValuesIncludingMargins
GeneratorTerminalPower
643907.7 kW
OverallGeneratorEfficiency
0.99
GeneratorReactivePower(kVAR)
482930.8
OverallLosses
6504.112 kW
MechanicalLosses
0 kW
FractionalMechanicalLosses
0 fraction
ElectricalLosses
0 kW
FractionalElectricalLosses
0 fraction
LossesduetoCoolant
0 kW
FractionalLossesduetoCoolant
0 fraction
AbsoluteMarginLossesforGTcomponents
0 kW
AbsoluteMarginLossesforSTcomponents
0 kW
CurrentValuesWithoutMargins
GeneratorShaftPowerw/oMargin
650411.8 kW
GeneratorTerminalPowerw/oMargin
643907.7 kW
OverallGeneratorEfficiencyw/oMargin
0.99
GeneratorReactivePower(kVAR)w/oMargin
482930.8
OverallLossesw/oMargin
6504.112 kW
MechanicalLossesw/oMargin
0 kW
FractionalMechanicalLossesw/oMargin
0 fraction
ElectricalLossesw/oMargin
0 kW
FractionalElectricalLossesw/oMargin
0 fraction
LossesduetoCoolantw/oMargin
0 kW
FractionalLossesduetoCoolantw/oMargin
0 fraction
Connections
ShaftValues
InletShaftSpeed
3000
InletShaftPower
650411.8 kW
EquipmentID:HPSHType:SPHTDescription:SuperheaterGotoTop
GasInlet GasOutlet
Steam
Steam
Flows
kg/sec
Pressure
kPa
Temperature
C
Enthalpy
kJ/kg
VaporFraction
onaweight
fraction
basis
Molecular
Weight
LowerHeating
kJ/kg
Value
Oxygen,O2
fraction
Nitrogen,N2
fraction
Water,H2O
fraction
Carbon
fraction
Monoxide,CO
CarbonDioxide,
fraction
CO2
Methane,CH4 fraction
Hydrogen,H2 fraction
Argon,AR
fraction
Carbonyl
fraction
Sulfide,COS
Hydrogen
fraction
Sulfide,H2S
SulfurDioxide,
fraction
SO2
751.1221
100.9001
973.35
1129.701
Inlet
Outlet
751.1221 506.8741 506.8741
100.900126891.200226353.3755
706.7551
396.85
440
789.5119 2360.389 2864.5053
1
29.5302
29.5302
0.0172
0.708
0.1139
0.0172
0.708
0.1139
0.15
0.15
0
0
0.0084
0
0
0.0084
0.0024
0.0024
MainInputs
CalculationMode
Design
SuperheaterMethodFlag
SteamOutletTemperature
DesiredSteamOutletTemperature
440 C
SteamOutletTemperature
DesignUAMethod
440 C
SpecifyHeatTransferCoefficient
OverallHeatTransferCoefficient
0.0454 kJ/sec-m^2-K
ConfigurationMethod
Cross-Counter-Current,1Tube
RowTotal,OuterFlowMixed,Inner
OnlyMixedbetweenPasses
NumberofHTXPasses
10
CpCalculationalMethod
Normal/Integrated
Control
MaximumTemperatureMethod
MaximumSteamTemperature
593.48 C
PerformanceFactors
HeatTransferCoefficientPerformanceFactor
HotSidePressureLossPerformanceFactor
ColdSidePressureLossPerformanceFactor
Losses
HotsidePressureDropFractionFlag
Checked
Hotsidepressureloss
0 fraction
ColdsidePressureDropFractionFlag
Coldsidepressureloss
Checked
0.02 fraction
Energylossfraction
0 fraction
Foulingfactor
0 m^2-K-sec/kJ
CurrentValues
SurfaceArea
14321.48 m^2
CalculatedEffectiveness
0.4776
CalculatedApproachTemperature(HotIn-ColdOut)
533.35 C
CalculatedApproachTemperature(HotOut-ColdIn)
309.9051 C
CalculatedDegreesofSuperheat
0C
RadiantConvectiveLosses
0 kJ/sec
CalculatedDuty
255523.5 kJ/sec
CalculatedNTU
0.6788
OverallHeatTransferCoefficient
0.0454 kJ/sec-m^2-K
ExergeticEfficiency(beta!)
0.9533
Hotsidepressureloss
0 fraction
Coldsidepressureloss
0.02 fraction
Energylossfraction
0 fraction
Foulingfactor
0 m^2-K-sec/kJ
Limits
MaximumOverallHeatTransferCoefficient
0.2839 kJ/sec-m^2-K
MinimumOverallHeatTransferCoefficient
0.0284 kJ/sec-m^2-K
MaximumHotSidePressureDrop
0.5 fraction
MinimumHotSidePressureDrop
0 fraction
MaximumColdSidePressureDrop
0.5 fraction
MinimumColdSidePressureDrop
0 fraction
EquipmentID:HPSPRYType:TMIXDescription:TemperatureControlMixerGo
toTop
Control
Inlet
kg/sec
506.8741 506.8741
0
kPa
26353.375526353.375528000.0004
C
440
440
163.415
kJ/kg
2864.5053 2864.5053 706.5607
MainInlet
Outlet
Flows
Pressure
Temperature
Enthalpy
VaporFraction
onaweight
fraction
basis
MainInputs
TemperatureControlMethod
NoEnthalpyChange
NoPressureLoss
UnChecked
PressureControlMethod
Demand-FlowControlFlag
ControlFlowDampingFactor
MacroLoopSetupFlag
0
UnChecked
UnChecked
DisableWarningwhenControlCannotBeAchieved
EqualizeInletPressures
UnChecked
CurrentValues
TemperatureChange
0C
DegreesofSuperheat
65.8639 C
PressureDrop
0 fraction
ExergeticEfficiency(beta!)
Limits
MinimumControlFlowMethod
NoMinimumControlFlowLimits
EquipmentID:HPSTType:STDescription:SteamTurbineGotoTop
Flows
Pressure
Temperature
Enthalpy
VaporFraction
onaweight
basis
kg/sec
kPa
C
kJ/kg
Steam
Main
SecondExpansion
Inlet
Outlet Extraction LineEnd
506.8742 482.4448
24.4294 482.4448
25000
3500
4400
3500
535.9015 258.0455 284.4524 258.0455
3291.2091 2854.9647 2899.2793 2854.9647
fraction
MainInputs
BypassSTFlag
UnChecked
Design
CalculationMode
NumberofControlValves
RotationalSpeed
DesignEfficiencyMethod
3000
IsentropicExpansionEfficiency
User-InputEfficiency
DesignExtractionPressureMethod
0.9
InputExtractionPressures
InletandOutletPressureSettings
ControlValvePressureDrop
0.02 fraction
OutletPressure
DesignPressureMethod
3500 kPa
InputThrottlePressure
User-InputInletPressure
25000 kPa
InletThrottlePressure
25000 kPa
DesignExitPressureMethod
NoExitPressureDrop
P-CtrlTrigger
DefaultStagePressureRatio
0.8
PressureControlRes.Trig.
0.5
PressureControlDamping
TurnCriticalPressureCorrectionoff
0.75
UnChecked
ExtractionsandAdmissions
DesignExtractionFlowMethod
FlowRate
FlowExtraction2
24.4294 kg/sec
PressureExtraction2
4400 kPa
AENExtraction2
77353.04 mm^2
K-FactorExtraction2
34422563.52
kg^2-m^3/hr^2-kPa
kg
Extractionatthe1stStageBowl
UnChecked
UnChecked
UnChecked
ExtractionattheexitofGoverningStage
ExtractionattheexitofLastStage
TFRinUpstreamValveCheckbox
UnChecked
UnChecked
UnChecked
Checked
CondensingSectionFlag
DemandControlCalculations
IncludePowerinSystem
Limits/Losses
Shaft/GearboxLossFraction
0 fraction
MinimumAllowedExitQuality
0.9
MaximumAllowedInletTemperature
565.5601 C
EfficiencyPerformanceFactor
FlowCapacityPerformanceFactor
FlowCapacityPerformanceFactorMethod
ApplyFlowCap.PFtoall
Stages/Groups
CurrentValues
STInlet
NumberofControlValves
ControlValvePressureDrop
CurrentControlValveSet.
ValveConstant(Kv)
ThrottleFlowRatio
CurrentInletSpecificVolume
1
0.02 fraction
1
390.5593
kg^2-m^3/hr^2-kPakg
1
0.0123 m^3/kg
STOutlet
NumberofFlowEnds
ExhaustAnnulusArea
1
5.1654 m^2
CurrentAnnulusVelocity
0 m/sec
VolumetricFlowatELEP
0 m^3/sec
VolumetricFlowatELEPperFlowEnd
0 m^3/sec
QualityatELEP
ExhaustVolumetricFlow
0
29.1451 m^3/sec
ExhaustVolumetricFlowperFlowEnd
29.1451 m^3/sec
Bowl
CurrentBowlPressure
BowlStodolaCQ
CurrentInletAEN
CurrentInletK-factor
24500 kPa
56.5878
kg^2-m^3/hr^2-kPakg
17417.65 mm^2
1704856.896
kg^2-m^3/hr^2-kPakg
Extraction1
ExpansionLinePressure
ExpansionLineEnthalpyatExtractionPoint
4400 kPa
2899.279 kJ/kg
ExpansionLineQualityatExtractionPoint
GroupStageFlowCoefficient
CurrentAENExtraction
0 mm^2
CurrentK-factorExtraction
kg^2-m^3/hr^2-kPakg
LeakageFlowConstantExtraction1
kg^2-m^3/hr^2-kPakg
SCCExtractionEnthalpy
0 kJ/kg
SCCExtractionEnthalpyCorrection
kg^2-m^3/hr^2-kPakg
Extraction2
ExpansionLinePressure
ExpansionLineEnthalpyatExtractionPoint
ExpansionLineQualityatExtractionPoint
4400 kPa
2899.279 kJ/kg
1
kg^2-m^3/hr^2-kPakg
GroupStageFlowCoefficient
305.4958
CurrentAENExtraction
77353.04 mm^2
CurrentK-factorExtraction
LeakageFlowConstantExtraction2
SCCExtractionEnthalpy
SCCExtractionEnthalpyCorrection
34422563.52
kg^2-m^3/hr^2-kPakg
88261.6306
kg^2-m^3/hr^2-kPakg
2899.279 kJ/kg
1
Extraction3
ExpansionLinePressure
ExpansionLineEnthalpyatExtractionPoint
3500 kPa
2854.965 kJ/kg
ExpansionLineQualityatExtractionPoint
GroupStageFlowCoefficient
CurrentAENExtraction
0 mm^2
CurrentK-factorExtraction
kg^2-m^3/hr^2-kPakg
LeakageFlowConstantExtraction3
kg^2-m^3/hr^2-kPakg
SCCExtractionEnthalpy
0 kJ/kg
SCCExtractionEnthalpyCorrection
kg^2-m^3/hr^2-kPakg
Extraction4
ExpansionLinePressure
ExpansionLineEnthalpyatExtractionPoint
3500 kPa
2854.965 kJ/kg
ExpansionLineQualityatExtractionPoint
GroupStageFlowCoefficient
CurrentAENExtraction
0 mm^2
CurrentK-factorExtraction
kg^2-m^3/hr^2-kPakg
LeakageFlowConstantExtraction4
kg^2-m^3/hr^2-kPakg
SCCExtractionEnthalpy
0 kJ/kg
SCCExtractionEnthalpyCorrection
kg^2-m^3/hr^2-kPakg
NetSTSectionPower
220046.7 kW
CurrentGrossSectionPower
220046.7 kW
EquivalentGeneratorOutput
217846.2 kW
CurrentOverallEfficiency
0.8927
ExergeticEfficiency
0.9792
GeneratorLoss
Shaft/GearboxLosses
ShaftSpeed
ShaftWork
CurrentInlet-ELEPat1.5inHgEfficiency
CurrentInlet-ELEPEfficiency
CurrentInlet-LastExtractionEfficiency
CurrentBowl-ShiftedELEPat1.5inHgEfficiency
CurrentInlet-UEEPEfficiency
CurrentEnthalpyat1.5Hg
2200.465 kW
0 kW
3000
220046.7 kW
0
0.9
0.8955
0
0.9
0 kJ/kg
CurrentELEP
2854.965 kJ/kg
CurrentUEEP
2854.965 kJ/kg
ExhaustAnnulusArea
5.1654 m^2
ExhaustVolumetricFlow
29.1451 m^3/sec
ExhaustVolumetricFlowperFlowEnd
29.1451 m^3/sec
VolumetricFlowatELEP
0 m^3/sec
VolumetricFlowatELEPperFlowEnd
0 m^3/sec
CurrentExhaustLoss
0 kJ/kg
CurrentExhaustLoss(fraction)
CurrentExitAEN
0 mm^2
CurrentExitFractionalPressureDrop
CurrentExitValveConstant
QualityatELEP
FirstStageNegativeReaction
GoverningStageAvailableEnergy
0 kJ/kg
GoverningStageEfficiency
GroupStageEfficiency1
0
0.8955
GroupStageEfficiency2
GroupStageEfficiency3
0.8988
GroupStageEfficiency4
GroupStageEfficiency5
GroupStageCriticalPressureRatio1
0.098
GroupStageCriticalPressureRatio2
GroupStageCriticalPressureRatio3
0.5358
GroupStageCriticalPressureRatio4
GroupStageCriticalPressureRatio5
GroupStagePressureRatio1
GroupStagePressureRatio2
0.1796
1
GroupStagePressureRatio3
0.7955
GroupStagePressureRatio4
GroupStagePressureRatio5
FlowCoefficient-StageGroup1
56.5878
kg^2-m^3/hr^2-kPakg
FlowCoefficient-StageGroup2
kg^2-m^3/hr^2-kPakg
FlowCoefficient-StageGroup3
305.4958
kg^2-m^3/hr^2-kPakg
FlowCoefficient-StageGroup4
kg^2-m^3/hr^2-kPakg
FlowCoefficient-StageGroup5
kg^2-m^3/hr^2-kPakg
SCCEnthalpy-1stExtraction
0 kJ/kg
SCCEnthalpy-2ndExtraction
2899.279 kJ/kg
SCCEnthalpy-3rdExtraction
0 kJ/kg
SCCEnthalpy-4thExtraction
0 kJ/kg
SCCEnthalpyCorrection-1stExtraction
SCCEnthalpyCorrection-2ndExtraction
SCCEnthalpyCorrection-3rdExtraction
SCCEnthalpyCorrection-4thExtraction
Pump1Power
0 kW
Pump2Power
0 kW
Pump3Power
0 kW
Pump4Power
0 kW
EquipmentID:HX1Type:HEATXDescription:GeneralHeatExchangerGotoTop
HotInlet HotOutlet ColdInlet
Flows
kg/sec
Pressure
kPa
Temperature
C
Enthalpy
kJ/kg
Molecular
Weight
LowerHeating
kJ/kg
Value
Oxygen,O2
fraction
Nitrogen,N2
fraction
Water,H2O
fraction
Carbon
fraction
Monoxide,CO
CarbonDioxide,
fraction
CO2
Methane,CH4 fraction
Hydrogen,H2 fraction
Argon,AR
fraction
Carbonyl
fraction
Sulfide,COS
Hydrogen
fraction
Sulfide,H2S
SulfurDioxide,
fraction
SO2
Cold
Outlet
677.7367
101.0112
368.2873
367.0504
751.1221
100.9001
449.4682
478.5371
751.1221
100.9001
166.6958
160.3123
677.7367
101.0112
29.67
14.3682
29.5302
29.5303
28.6943
28.6943
0.0172
0.708
0.1139
0.0172
0.708
0.1139
0.2043
0.7615
0.0247
0.2043
0.7615
0.0247
0.15
0.15
0.0003
0.0003
0
0
0.0084
0
0
0.0084
0
0
0.0091
0
0
0.0091
0.0024
0.0024
MainInputs
CalculationMode
Design
DesignMethod
Effectiveness
DesiredEffectiveness
0.8
CalculatedEffectiveness
0.8
HeatTransferCoefficientMethod
OverallHeatTransferCoefficient
OverallHeatTransferCoefficient
0.0454 kJ/sec-m^2-K
ConfigurationMethod
Cross-Counter-Current,1Tube
RowTotal,OuterFlowMixed,Inner
OnlyMixedbetweenPasses
NumberofHTXPasses
10
HotsidePhaseChangeMessages
UnChecked
UnChecked
ColdsidePhaseChangeMessages
Leakage
HotSideLeakageFraction
0 fraction
ColdSideLeakageFraction
0 fraction
PerformanceFactors
HeatTransferCoefficientPerformanceFactor
HotSidePressureLossPerformanceFactor
ColdSidePressureLossPerformanceFactor
Losses
HotsidePressureDropFractionFlag
Checked
Hotsidepressureloss
0 fraction
ColdsidePressureDropFractionFlag
Coldsidepressureloss
Checked
0 fraction
Energylossfraction
0 fraction
Foulingfactor
0 m^2-K-sec/kJ
CurrentValues
SurfaceArea
48344.04 m^2
CalculatedDuty
239025.7 kJ/sec
CalculatedNTU
3.1111
Energylossfraction
0 fraction
Foulingfactor
0 m^2-K-sec/kJ
RadiantConvectiveLosses
0 kJ/sec
CalculatedEffectiveness
ExergeticEfficiency(beta!)
0.8
0.75
CalculatedPinch(HotOut-ColdIn)
137.0258 C
CalculatedPinch(HotIn-ColdOut)
81.1809 C
OverallHeatTransferCoefficient
0.0454 kJ/sec-m^2-K
Hotsidepressureloss
0 fraction
Coldsidepressureloss
0 fraction
Limits
MaximumOverallHeatTransferCoefficient
0.2839 kJ/sec-m^2-K
MinimumOverallHeatTransferCoefficient
0.0284 kJ/sec-m^2-K
MaximumHotSidePressureDrop
0.5 fraction
MinimumHotSidePressureDrop
0 fraction
MaximumColdSidePressureDrop
0.5 fraction
MinimumColdSidePressureDrop
0 fraction
MinimumPinchLimit
0C
EquipmentID:IPSHType:SPHTDescription:SuperheaterGotoTop
GasInlet GasOutlet
Flows
kg/sec
Pressure
kPa
Temperature
C
Enthalpy
kJ/kg
VaporFraction
onaweight
fraction
basis
Molecular
Weight
LowerHeating
kJ/kg
Value
Oxygen,O2
fraction
Nitrogen,N2
fraction
Water,H2O
fraction
Carbon
fraction
Monoxide,CO
CarbonDioxide,
fraction
CO2
Methane,CH4 fraction
Hydrogen,H2 fraction
Argon,AR
fraction
Carbonyl
fraction
Sulfide,COS
Hydrogen
fraction
Sulfide,H2S
SulfurDioxide,
fraction
SO2
751.1221
100.9001
706.7551
789.5119
751.1221
100.9001
476.006
509.6665
Steam
Steam
Inlet
Outlet
455.5999 455.5999
3500
3430
258.0455 439.9993
2854.9647 3316.3568
1
29.5302
29.5302
0.0172
0.708
0.1139
0.0172
0.708
0.1139
0.15
0.15
0
0
0.0084
0
0
0.0084
0.0024
0.0024
MainInputs
CalculationMode
Design
SuperheaterMethodFlag
SteamOutletTemperature
DesiredSteamOutletTemperature
440 C
SteamOutletTemperature
DesignUAMethod
439.9993 C
SpecifyHeatTransferCoefficient
OverallHeatTransferCoefficient
0.0454 kJ/sec-m^2-K
ConfigurationMethod
Cross-Counter-Current,1Tube
RowTotal,OuterFlowMixed,Inner
OnlyMixedbetweenPasses
NumberofHTXPasses
10
CpCalculationalMethod
Normal/Integrated
MaximumTemperatureMethod
MaximumSteamTemperature
Control
593.48 C
PerformanceFactors
HeatTransferCoefficientPerformanceFactor
HotSidePressureLossPerformanceFactor
ColdSidePressureLossPerformanceFactor
Losses
HotsidePressureDropFractionFlag
Checked
Hotsidepressureloss
0 fraction
ColdsidePressureDropFractionFlag
Checked
Coldsidepressureloss
0.02 fraction
Energylossfraction
0 fraction
Foulingfactor
0 m^2-K-sec/kJ
CurrentValues
SurfaceArea
20228.2 m^2
CalculatedEffectiveness
0.5289
CalculatedApproachTemperature(HotIn-ColdOut)
266.7558 C
CalculatedApproachTemperature(HotOut-ColdIn)
217.9605 C
CalculatedDegreesofSuperheat
198.6167 C
RadiantConvectiveLosses
0 kJ/sec
CalculatedDuty
210210.2 kJ/sec
CalculatedNTU
1.0087
OverallHeatTransferCoefficient
0.0454 kJ/sec-m^2-K
ExergeticEfficiency(beta!)
0.9575
Hotsidepressureloss
0 fraction
Coldsidepressureloss
0.02 fraction
Energylossfraction
0 fraction
Foulingfactor
0 m^2-K-sec/kJ
Limits
MaximumOverallHeatTransferCoefficient
0.2839 kJ/sec-m^2-K
MinimumOverallHeatTransferCoefficient
0.0284 kJ/sec-m^2-K
MaximumHotSidePressureDrop
0.5 fraction
MinimumHotSidePressureDrop
0 fraction
MaximumColdSidePressureDrop
0.5 fraction
MinimumColdSidePressureDrop
0 fraction
EquipmentID:IPSPRYType:TMIXDescription:TemperatureControlMixerGoto
Top
MainInlet
Flows
Pressure
Temperature
Enthalpy
VaporFraction
onaweight
basis
MainInputs
kg/sec
kPa
C
kJ/kg
fraction
455.5999
3430
439.9993
3316.3568
1
Control
Inlet
455.5998
0
343028000.0004
439.9993
163.415
3316.3568 706.5607
Outlet
TemperatureControlMethod
NoEnthalpyChange
NoPressureLoss
UnChecked
PressureControlMethod
Demand-FlowControlFlag
ControlFlowDampingFactor
MacroLoopSetupFlag
UnChecked
UnChecked
UnChecked
DisableWarningwhenControlCannotBeAchieved
EqualizeInletPressures
CurrentValues
TemperatureChange
0C
DegreesofSuperheat
198.6167 C
PressureDrop
0 fraction
ExergeticEfficiency(beta!)
Limits
MinimumControlFlowMethod
NoMinimumControlFlowLimits
EquipmentID:IPSTType:STDescription:SteamTurbineGotoTop
Flows
Pressure
Temperature
Enthalpy
VaporFraction
onaweight
basis
kg/sec
kPa
C
kJ/kg
Steam
Main
FirstExpansion
Inlet
Outlet Extraction LineEnd
455.5999 418.9822
36.6177 418.9822
3395.7
700
2200
700
539.9989 322.0595 477.0691 322.0595
3541.8098 3105.9542 3414.6271 3105.9542
fraction
MainInputs
BypassSTFlag
UnChecked
CalculationMode
Design
NumberofControlValves
RotationalSpeed
DesignEfficiencyMethod
3000
IsentropicExpansionEfficiency
User-InputEfficiency
DesignExtractionPressureMethod
0.9
InputExtractionPressures
InletandOutletPressureSettings
ControlValvePressureDrop
0.02 fraction
OutletPressure
DesignPressureMethod
700 kPa
ThrottlePressureSetUpstream
NoExitPressureDrop
DesignExitPressureMethod
P-CtrlTrigger
DefaultStagePressureRatio
0.8
PressureControlRes.Trig.
0.5
PressureControlDamping
TurnCriticalPressureCorrectionoff
0.75
UnChecked
FlowRate
ExtractionsandAdmissions
DesignExtractionFlowMethod
FlowExtraction1
36.6177 kg/sec
PressureExtraction1
2200 kPa
AENExtraction1
167568.2 mm^2
K-FactorExtraction1
1.5953E08
kg^2-m^3/hr^2-kPa
kg
Extractionatthe1stStageBowl
UnChecked
UnChecked
UnChecked
ExtractionattheexitofGoverningStage
ExtractionattheexitofLastStage
TFRinUpstreamValveCheckbox
UnChecked
UnChecked
UnChecked
Checked
CondensingSectionFlag
DemandControlCalculations
IncludePowerinSystem
Limits/Losses
Shaft/GearboxLossFraction
0 fraction
MinimumAllowedExitQuality
0.9
MaximumAllowedInletTemperature
565.5601 C
EfficiencyPerformanceFactor
FlowCapacityPerformanceFactor
FlowCapacityPerformanceFactorMethod
0
ApplyFlowCap.PFtoall
Stages/Groups
CurrentValues
STInlet
NumberofControlValves
ControlValvePressureDrop
CurrentControlValveSet.
ValveConstant(Kv)
ThrottleFlowRatio
CurrentInletSpecificVolume
0
0.02 fraction
1
2823.6911
kg^2-m^3/hr^2-kPakg
1
0.1081 m^3/kg
STOutlet
NumberofFlowEnds
ExhaustAnnulusArea
1
5.1654 m^2
CurrentAnnulusVelocity
0 m/sec
VolumetricFlowatELEP
0 m^3/sec
VolumetricFlowatELEPperFlowEnd
0 m^3/sec
QualityatELEP
ExhaustVolumetricFlow
161.9763 m^3/sec
ExhaustVolumetricFlowperFlowEnd
161.9763 m^3/sec
Bowl
CurrentBowlPressure
3327.786 kPa
BowlStodolaCQ
450.0039
CurrentInletAEN
125201.7 mm^2
CurrentInletK-factor
89134706.88
kg^2-m^3/hr^2-kPakg
kg^2-m^3/hr^2-kPakg
Extraction1
ExpansionLinePressure
ExpansionLineEnthalpyatExtractionPoint
ExpansionLineQualityatExtractionPoint
GroupStageFlowCoefficient
CurrentAENExtraction
CurrentK-factorExtraction
LeakageFlowConstantExtraction1
SCCExtractionEnthalpy
SCCExtractionEnthalpyCorrection
2200 kPa
3414.627 kJ/kg
1
553.386
kg^2-m^3/hr^2-kPakg
167568.2 mm^2
1.5953E08
kg^2-m^3/hr^2-kPakg
1218546.8928
kg^2-m^3/hr^2-kPakg
3414.627 kJ/kg
1
Extraction2
ExpansionLinePressure
ExpansionLineEnthalpyatExtractionPoint
700 kPa
3105.954 kJ/kg
ExpansionLineQualityatExtractionPoint
GroupStageFlowCoefficient
CurrentAENExtraction
0 mm^2
CurrentK-factorExtraction
kg^2-m^3/hr^2-kPakg
LeakageFlowConstantExtraction2
kg^2-m^3/hr^2-kPakg
SCCExtractionEnthalpy
0 kJ/kg
SCCExtractionEnthalpyCorrection
kg^2-m^3/hr^2-kPakg
Extraction3
ExpansionLinePressure
ExpansionLineEnthalpyatExtractionPoint
700 kPa
3105.954 kJ/kg
ExpansionLineQualityatExtractionPoint
GroupStageFlowCoefficient
0 kg^2-m^3/hr^2-kPa-
kg
CurrentAENExtraction
0 mm^2
CurrentK-factorExtraction
kg^2-m^3/hr^2-kPakg
LeakageFlowConstantExtraction3
kg^2-m^3/hr^2-kPakg
SCCExtractionEnthalpy
0 kJ/kg
SCCExtractionEnthalpyCorrection
Extraction4
ExpansionLinePressure
ExpansionLineEnthalpyatExtractionPoint
700 kPa
3105.954 kJ/kg
ExpansionLineQualityatExtractionPoint
GroupStageFlowCoefficient
CurrentAENExtraction
0 mm^2
CurrentK-factorExtraction
kg^2-m^3/hr^2-kPakg
LeakageFlowConstantExtraction4
kg^2-m^3/hr^2-kPakg
SCCExtractionEnthalpy
0 kJ/kg
SCCExtractionEnthalpyCorrection
kg^2-m^3/hr^2-kPakg
NetSTSectionPower
187279.9 kW
CurrentGrossSectionPower
187279.9 kW
EquivalentGeneratorOutput
185407.1 kW
CurrentOverallEfficiency
ExergeticEfficiency
GeneratorLoss
Shaft/GearboxLosses
ShaftSpeed
ShaftWork
CurrentInlet-ELEPat1.5inHgEfficiency
CurrentInlet-ELEPEfficiency
CurrentInlet-LastExtractionEfficiency
CurrentBowl-ShiftedELEPat1.5inHgEfficiency
CurrentInlet-UEEPEfficiency
CurrentEnthalpyat1.5Hg
0.8904
0.9805
1872.797 kW
0 kW
3000
407326.6 kW
0
0.9
0.8756
0
0.9
0 kJ/kg
CurrentELEP
3105.954 kJ/kg
CurrentUEEP
3105.954 kJ/kg
ExhaustAnnulusArea
5.1654 m^2
ExhaustVolumetricFlow
161.9763 m^3/sec
ExhaustVolumetricFlowperFlowEnd
161.9763 m^3/sec
VolumetricFlowatELEP
0 m^3/sec
VolumetricFlowatELEPperFlowEnd
0 m^3/sec
CurrentExhaustLoss
0 kJ/kg
CurrentExhaustLoss(fraction)
CurrentExitAEN
0 mm^2
CurrentExitFractionalPressureDrop
CurrentExitValveConstant
QualityatELEP
FirstStageNegativeReaction
GoverningStageAvailableEnergy
0 kJ/kg
GoverningStageEfficiency
GroupStageEfficiency1
0.8756
GroupStageEfficiency2
0.8995
GroupStageEfficiency3
0
GroupStageEfficiency4
GroupStageEfficiency5
GroupStageCriticalPressureRatio1
0.4113
GroupStageCriticalPressureRatio2
0.1767
GroupStageCriticalPressureRatio3
GroupStageCriticalPressureRatio4
GroupStageCriticalPressureRatio5
GroupStagePressureRatio1
0.6611
GroupStagePressureRatio2
0.3182
GroupStagePressureRatio3
GroupStagePressureRatio4
GroupStagePressureRatio5
FlowCoefficient-StageGroup1
450.0039
kg^2-m^3/hr^2-kPakg
FlowCoefficient-StageGroup2
553.386
kg^2-m^3/hr^2-kPakg
FlowCoefficient-StageGroup3
kg^2-m^3/hr^2-kPakg
FlowCoefficient-StageGroup4
kg^2-m^3/hr^2-kPakg
FlowCoefficient-StageGroup5
kg^2-m^3/hr^2-kPakg
SCCEnthalpy-1stExtraction
3414.627 kJ/kg
SCCEnthalpy-2ndExtraction
0 kJ/kg
SCCEnthalpy-3rdExtraction
0 kJ/kg
SCCEnthalpy-4thExtraction
0 kJ/kg
SCCEnthalpyCorrection-1stExtraction
SCCEnthalpyCorrection-2ndExtraction
SCCEnthalpyCorrection-3rdExtraction
SCCEnthalpyCorrection-4thExtraction
Pump1Power
0 kW
Pump2Power
0 kW
Pump3Power
0 kW
Pump4Power
0 kW
EquipmentID:LPSTType:STDescription:SteamTurbineGotoTop
Flows
Pressure
Temperature
Enthalpy
VaporFraction
onaweight
basis
kg/sec
kPa
C
kJ/kg
Steam
Main
First
Second
Third
FourthExpansion
Inlet
Outlet Extraction Extraction Extraction Extraction LineEnd
407.6131 349.3029
18.3933
0
22.0549
17.8634 349.3029
700
13.7897
400
200.486
200
60
13.7897
322.0595
52.2641 259.3345 187.4849 187.2478
85.9539
52.2641
3105.9542 2456.5621 2983.7367 2845.1414 2844.6874 2645.1561 2446.5621
fraction
0.9413
0.9963
MainInputs
BypassSTFlag
UnChecked
Design
CalculationMode
NumberofControlValves
RotationalSpeed
DesignEfficiencyMethod
3000
IsentropicExpansionEfficiency
User-InputEfficiency
DesignExtractionPressureMethod
0.9
InputExtractionPressures
0.9371
InletandOutletPressureSettings
ControlValvePressureDrop
0.02 fraction
OutletPressure
DesignPressureMethod
13.7897 kPa
ThrottlePressureSetUpstream
NoExitPressureDrop
DesignExitPressureMethod
P-CtrlTrigger
DefaultStagePressureRatio
0.8
PressureControlRes.Trig.
0.5
PressureControlDamping
TurnCriticalPressureCorrectionoff
0.75
UnChecked
ExtractionsandAdmissions
DesignExtractionFlowMethod
FlowRate
FlowExtraction1
18.3933 kg/sec
PressureExtraction1
400 kPa
AENExtraction1
716459.5 mm^2
K-FactorExtraction1
2.9765E09
kg^2-m^3/hr^2-kPa
kg
DesignExtractionFlowMethod
FlowRate
FlowExtraction2
0 kg/sec
PressureExtraction2
200.486 kPa
AENExtraction2
1329804 mm^2
K-FactorExtraction2
1.0262E10
kg^2-m^3/hr^2-kPa
kg
DesignExtractionFlowMethod
FlowRate
FlowExtraction3
22.0549 kg/sec
PressureExtraction3
200 kPa
AENExtraction3
1257178 mm^2
K-FactorExtraction3
9.1715E09
kg^2-m^3/hr^2-kPa
kg
DesignExtractionFlowMethod
FlowRate
FlowExtraction4
17.8634 kg/sec
PressureExtraction4
60 kPa
AENExtraction4
3511078 mm^2
K-FactorExtraction4
7.173E10
kg^2-m^3/hr^2-kPa
kg
Extractionatthe1stStageBowl
UnChecked
UnChecked
UnChecked
ExtractionattheexitofGoverningStage
ExtractionattheexitofLastStage
TFRinUpstreamValveCheckbox
UnChecked
Checked
CondensingSectionFlag
ExpansionEfficiencyDefinition
BowltoUsed-EnergyEndPoint
(UEEP)
Exhaust-LossCalculationMethod
UserInputExhaustLoss
User-InputExhaustLoss
10 kJ/kg
CurrentExhaustLoss
10 kJ/kg
LastStageBucketLength
762 mm
ExhaustAnnulusArea
5.1654 m^2
NumberofFlowEnds
DemandControlCalculations
UnChecked
Checked
IncludePowerinSystem
Limits/Losses
Shaft/GearboxLossFraction
0 fraction
MinimumAllowedExitQuality
0.9
MaximumAllowedInletTemperature
565.5601 C
EfficiencyPerformanceFactor
FlowCapacityPerformanceFactor
FlowCapacityPerformanceFactorMethod
0
ApplyFlowCap.PFtoall
Stages/Groups
CurrentValues
STInlet
NumberofControlValves
ControlValvePressureDrop
CurrentControlValveSet.
ValveConstant(Kv)
ThrottleFlowRatio
CurrentInletSpecificVolume
0
0.02 fraction
1
10524.711
kg^2-m^3/hr^2-kPakg
1
0.3866 m^3/kg
STOutlet
NumberofFlowEnds
ExhaustAnnulusArea
2
5.1654 m^2
CurrentAnnulusVelocity
343.6891 m/sec
VolumetricFlowatELEP
3550.584 m^3/sec
VolumetricFlowatELEPperFlowEnd
1775.292 m^3/sec
QualityatELEP
0.9371
ExhaustVolumetricFlow
3566.542 m^3/sec
ExhaustVolumetricFlowperFlowEnd
1783.271 m^3/sec
Bowl
CurrentBowlPressure
686 kPa
kg^2-m^3/hr^2-kPakg
BowlStodolaCQ
1627.036
CurrentInletAEN
463129.8 mm^2
CurrentInletK-factor
1.2383E09
kg^2-m^3/hr^2-kPakg
Extraction1
ExpansionLinePressure
ExpansionLineEnthalpyatExtractionPoint
ExpansionLineQualityatExtractionPoint
GroupStageFlowCoefficient
CurrentAENExtraction
CurrentK-factorExtraction
LeakageFlowConstantExtraction1
SCCExtractionEnthalpy
SCCExtractionEnthalpyCorrection
400 kPa
2983.737 kJ/kg
1
2465.7735
kg^2-m^3/hr^2-kPakg
716459.5 mm^2
2.9765E09
kg^2-m^3/hr^2-kPakg
6645922.992
kg^2-m^3/hr^2-kPakg
2983.737 kJ/kg
1
Extraction2
ExpansionLinePressure
ExpansionLineEnthalpyatExtractionPoint
ExpansionLineQualityatExtractionPoint
GroupStageFlowCoefficient
CurrentAENExtraction
CurrentK-factorExtraction
LeakageFlowConstantExtraction2
SCCExtractionEnthalpy
SCCExtractionEnthalpyCorrection
200.486 kPa
2845.141 kJ/kg
1
42645.852
kg^2-m^3/hr^2-kPakg
1329804 mm^2
1.0262E10
kg^2-m^3/hr^2-kPakg
kg^2-m^3/hr^2-kPakg
2845.141 kJ/kg
1
Extraction3
ExpansionLinePressure
ExpansionLineEnthalpyatExtractionPoint
ExpansionLineQualityatExtractionPoint
GroupStageFlowCoefficient
CurrentAENExtraction
CurrentK-factorExtraction
LeakageFlowConstantExtraction3
SCCExtractionEnthalpy
SCCExtractionEnthalpyCorrection
200 kPa
2844.687 kJ/kg
1
4187.7233
kg^2-m^3/hr^2-kPakg
1257178 mm^2
9.1715E09
kg^2-m^3/hr^2-kPakg
33092102.88
kg^2-m^3/hr^2-kPakg
2844.687 kJ/kg
1
Extraction4
ExpansionLinePressure
ExpansionLineEnthalpyatExtractionPoint
ExpansionLineQualityatExtractionPoint
GroupStageFlowCoefficient
CurrentAENExtraction
60 kPa
2645.156 kJ/kg
0.9963
11642.0043
kg^2-m^3/hr^2-kPakg
3511078 mm^2
CurrentK-factorExtraction
7.173E10
kg^2-m^3/hr^2-kPakg
LeakageFlowConstantExtraction4
1.876E08
kg^2-m^3/hr^2-kPakg
SCCExtractionEnthalpy
2645.156 kJ/kg
SCCExtractionEnthalpyCorrection
NetSTSectionPower
243085.2 kW
CurrentGrossSectionPower
243085.2 kW
EquivalentGeneratorOutput
240654.3 kW
CurrentOverallEfficiency
ExergeticEfficiency
GeneratorLoss
Shaft/GearboxLosses
ShaftSpeed
ShaftWork
0.8963
0.9288
2430.849 kW
0 kW
3000
650411.8 kW
CurrentInlet-ELEPat1.5inHgEfficiency
0.9037
CurrentInlet-ELEPEfficiency
0.9139
CurrentInlet-LastExtractionEfficiency
0.9136
CurrentBowl-ShiftedELEPat1.5inHgEfficiency
CurrentInlet-UEEPEfficiency
0
0.9
CurrentEnthalpyat1.5Hg
2336.973 kJ/kg
CurrentELEP
2446.562 kJ/kg
CurrentUEEP
2456.562 kJ/kg
ExhaustAnnulusArea
5.1654 m^2
ExhaustVolumetricFlow
3566.542 m^3/sec
ExhaustVolumetricFlowperFlowEnd
1783.271 m^3/sec
VolumetricFlowatELEP
3550.584 m^3/sec
VolumetricFlowatELEPperFlowEnd
1775.292 m^3/sec
CurrentExhaustLoss
10 kJ/kg
CurrentExhaustLoss(fraction)
CurrentExitAEN
0 mm^2
CurrentExitFractionalPressureDrop
CurrentExitValveConstant
QualityatELEP
0
0.9371
FirstStageNegativeReaction
GoverningStageAvailableEnergy
0 kJ/kg
GoverningStageEfficiency
GroupStageEfficiency1
0.8901
GroupStageEfficiency2
0.8958
GroupStageEfficiency3
0.8918
GroupStageEfficiency4
0.9064
GroupStageEfficiency5
0.8976
GroupStageCriticalPressureRatio1
0.35
GroupStageCriticalPressureRatio2
0.2908
GroupStageCriticalPressureRatio3
0.54
GroupStageCriticalPressureRatio4
0.1662
GroupStageCriticalPressureRatio5
0.1261
GroupStagePressureRatio1
0.5831
GroupStagePressureRatio2
0.5012
GroupStagePressureRatio3
0.9976
GroupStagePressureRatio4
0.3
GroupStagePressureRatio5
0.2298
FlowCoefficient-StageGroup1
1627.036
kg^2-m^3/hr^2-kPakg
FlowCoefficient-StageGroup2
2465.7735
kg^2-m^3/hr^2-kPakg
FlowCoefficient-StageGroup3
42645.852
kg^2-m^3/hr^2-kPakg
FlowCoefficient-StageGroup4
4187.7233
kg^2-m^3/hr^2-kPakg
FlowCoefficient-StageGroup5
11642.0043
kg^2-m^3/hr^2-kPakg
SCCEnthalpy-1stExtraction
2983.737 kJ/kg
SCCEnthalpy-2ndExtraction
2845.141 kJ/kg
SCCEnthalpy-3rdExtraction
2844.687 kJ/kg
SCCEnthalpy-4thExtraction
2645.156 kJ/kg
SCCEnthalpyCorrection-1stExtraction
SCCEnthalpyCorrection-2ndExtraction
SCCEnthalpyCorrection-3rdExtraction
SCCEnthalpyCorrection-4thExtraction
Pump1Power
0 kW
Pump2Power
0 kW
Pump3Power
0 kW
Pump4Power
0 kW
EquipmentID:M1Type:MIXERDescription:MixerGotoTop
Flows
Pressure
Temperature
Enthalpy
VaporFraction
onaweight
basis
kg/sec
kPa
C
kJ/kg
fraction
Primary
Secondary
Outlet
Inlet
Inlet
349.3029 407.6146
58.3117
980
980
1000
80.4365
81.1748
85.5914
337.4892 340.5864 359.1395
0
MainInputs
DemandFlowControlFlag
UnChecked
UnChecked
EqualizeInletPressures
EquipmentID:MU1Type:MAKEUPDescription:MakeupGotoTop
Flows
Pressure
Temperature
Enthalpy
VaporFraction
onaweight
basis
kg/sec
kPa
C
kJ/kg
fraction
Outlet
0
103.42
15.56
65.3825
0
MainInputs
MakeupBlockType
Automatic
TemperatureandPressure
Calculation(flash)Method
Flow
0 kg/sec
OutletPressure
103.42 kPa
OutletTemperature
HeatRateAdjustmentFlag
15.56 C
Flowdoesnotaffectoverall
heatrate
MassFlowDampingFactor
IterationStartforDamping
UserInputMinimumMassFlowWarning
0 kg/sec
EquipmentID:RCYPMPType:PUMPDescription:PumpGotoTop
MainInlet
Flows
Pressure
Temperature
Enthalpy
VaporFraction
onaweight
basis
kg/sec
kPa
C
kJ/kg
58.3117
58.8
85.4365
357.7527
fraction
Control Internal
Valve
Pump
Outlet
Flow
58.3117
58.3117
1000
58.8
85.5914
85.4365
359.1395 357.7527
0
MainInputs
CalculationMode
Design
PumpExitPressureMethodFlag
PumpExitPressure
DesiredPumpExitPressure
1200 kPa
CalculatedPumpExitPressure
VariableSpeedflag
1200 kPa
UnChecked
InputEfficiency
EfficiencyMethodFlag
DesiredIsentropicEfficiency
0.85
ActualIsentropicEfficiency
0.85
RatedFlowMethodFlag
RatedMassFlow
DesiredRatedMassFlowRate
0 kg/sec
RatedMassFlowRate
0 kg/sec
MinimumFlowFlagY/N
Checked
MinimumFlowRate
0 kg/sec
RatedHead
0m
RatedSpeed
3600
ControlMethodFlag
FixedControlValveOutletPressure
DesiredControlValveOutletPressure
1000 kPa
OutletPressure
1000 kPa
EfficiencyMethodSubFlag
HydraulicMethod
Checked
IncludePowerinBOP
Miscellaneous
Motor/GearboxLossFraction
0 fraction
RecirculationRate
CurrentValues
ActualIsentropicEfficiency
0.85
CalculatedPressureRatio
17.0068
CalculatedPumpExitPressure
1200 kPa
CalculatedP.Diff(PumpExit-ControlValveExit)
199.9999 kPa
DevelopedHead
120.1986 m
NetPositiveSuctionHeadAvailable
0m
RecirculationRate
PumpWork
-80.8687 kW
ShaftLosses
0 kW
Motor/GearboxLossFraction
0 fraction
InletSpecificVolume
0.001 m^3/kg
RatedMassFlowRate
0 kg/sec
RatedVolumetricFlowRate
0 m^3/sec
RatedSpeed
3600
RatedHead
0m
ExergeticEfficiency(beta!)
0.9837
ShaftValues
InletShaftSpeed
3600
OutletShaftSpeed
3600
EquipmentID:SP1Type:SPLITRDescription:SplitterGotoTop
Inlet
Flows
kg/sec
Pressure
kPa
Temperature
C
Enthalpy
kJ/kg
Molecular
Weight
LowerHeating
kJ/kg
Value
Oxygen,O2
fraction
Nitrogen,N2
fraction
Water,H2O
fraction
Carbon
fraction
Monoxide,CO
CarbonDioxide,
fraction
CO2
Methane,CH4 fraction
Hydrogen,H2 fraction
Argon,AR
fraction
Carbonyl
fraction
Sulfide,COS
Hydrogen
fraction
Sulfide,H2S
SulfurDioxide,
fraction
SO2
677.7367
101.0112
368.2873
367.0504
PrimarySecondary
Outlet
Outlet
677.7367
0
101.0112 101.0112
368.2873 368.2873
367.0504 367.0504
28.6943
28.6943
28.6943
0.2043
0.7615
0.0247
0.2043
0.7615
0.0247
0.2043
0.7615
0.0247
0.0003
0.0003
0.0003
0
0
0.0091
0
0
0.0091
0
0
0.0091
MainInputs
StreamIDatPrimaryPort
S17
PrimaryPortControlMethod
DownStreamFlowControl
StreamIDatSecondaryPort
S18
SecondaryPortControlMethod
DownStreamFlowControl
NONE
StreamIDatTertiaryPort
CurrentValues
PrimaryPortDesiredFraction
1 fraction
SecondaryPortDesiredFraction
0 fraction
TertiaryPortDesiredFraction
0 fraction
EquipmentID:SP2Type:SPLITRDescription:SplitterGotoTop
Inlet
Flows
Pressure
Temperature
Enthalpy
VaporFraction
onaweight
basis
kg/sec
kPa
C
kJ/kg
418.9822
700
322.0595
3105.9542
fraction
PrimarySecondary
Outlet
Outlet
11.3691 407.6131
700
700
322.0595 322.0595
3105.9542 3105.9542
1
MainInputs
StreamIDatPrimaryPort
S37
PrimaryPortControlMethod
DownStreamFlowControl
StreamIDatSecondaryPort
S36
SecondaryPortControlMethod
RemainderPort
NONE
StreamIDatTertiaryPort
CurrentValues
PrimaryPortDesiredFraction
0.0271 fraction
SecondaryPortDesiredFraction
0.9729 fraction
TertiaryPortDesiredFraction
0 fraction
EquipmentID:SP3Type:SPLITRDescription:SplitterGotoTop
Inlet
Flows
Pressure
Temperature
Enthalpy
VaporFraction
onaweight
basis
kg/sec
kPa
C
kJ/kg
482.4448
3500
258.0455
2854.9647
fraction
PrimarySecondary
Outlet
Outlet
26.8449 455.5999
3500
3500
258.0455 258.0455
2854.9647 2854.9647
1
MainInputs
StreamIDatPrimaryPort
S39
PrimaryPortControlMethod
DownStreamFlowControl
StreamIDatSecondaryPort
S38
SecondaryPortControlMethod
RemainderPort
NONE
StreamIDatTertiaryPort
CurrentValues
PrimaryPortDesiredFraction
0.0556 fraction
SecondaryPortDesiredFraction
0.9444 fraction
TertiaryPortDesiredFraction
0 fraction
EquipmentID:SP4Type:SPLITRDescription:SplitterGotoTop
PrimarySecondary Tertiary
Outlet
Outlet
Outlet
kg/sec
506.8741
0
0 506.8741
kPa
28000.000428000.000428000.000428000.0004
C
163.415
163.415
163.415
163.415
kJ/kg
706.5607 706.5607 706.5607 706.5607
Inlet
Flows
Pressure
Temperature
Enthalpy
VaporFraction
onaweight
fraction
basis
MainInputs
StreamIDatPrimaryPort
S49
PrimaryPortControlMethod
DownStreamFlowControl
StreamIDatSecondaryPort
S48
SecondaryPortControlMethod
DownStreamFlowControl
StreamIDatTertiaryPort
S24
TertiaryPortControlMethod
DownStreamFlowControl
CurrentValues
PrimaryPortDesiredFraction
0 fraction
SecondaryPortDesiredFraction
0 fraction
TertiaryPortDesiredFraction
1 fraction
EquipmentID:SRC1Type:SOURCEDescription:SourceGotoTop
Flows
Pressure
Temperature
Enthalpy
VaporFraction
onaweight
basis
Outlet
kg/sec 30957.5794
kPa
172.3689
C
32
kJ/kg
128.4762
fraction
MainInputs
DataSource
Usedatafromthiswindow
Calculation(flash)Method
Pressure-Temperature
SeaorSaltWater
Checked
DesiredSalinity(0/00)
30.5
Salinity(0/00)
30.5
HeatRateAdjustmentFlag
Flowdoesnotaffectoverall
heatrate
Flow
30957.58 kg/sec
Pressure
172.3689 kPa
Temperature
32 C
EquipmentID:STACKType:EXHDescription:EXHGotoTop
Flows
kg/sec
Pressure
kPa
Temperature
C
Enthalpy
kJ/kg
Molecular
Weight
LowerHeating
kJ/kg
Value
Oxygen,O2
fraction
Nitrogen,N2
fraction
Water,H2O
fraction
Carbon
fraction
Monoxide,CO
CarbonDioxide,
fraction
CO2
Methane,CH4 fraction
Hydrogen,H2 fraction
Argon,AR
fraction
Carbonyl
fraction
Sulfide,COS
Hydrogen
fraction
Sulfide,H2S
SulfurDioxide,
fraction
SO2
Inlet
751.1221
100.9001
166.6958
160.3123
29.5303
0
0.0172
0.708
0.1139
0
0.15
0
0
0.0084
0
0
0.0024
MainInputs
PressureControlMethod
NoPressureControl
StackWarningTemperature
HeatRateAdjustmentFlag
93.33 C
Flowdoesnotaffectoverall
heatrate
AcidDewPointControlMethod
Usesallaciddewpointcalculation
methods
SO2toSO3(H2SO4)conversion(fraction)
0 fraction
CurrentValues
LowerHeatingValue(LHV)
WaterDewPoint
0 kJ/kg
48.5785 C
AcidDewPoint(ABB)
0C
AcidDewPoint(Martin)
0C
AcidDewPoint(Ganapathy)
0C
AcidDewPoint(Verhoff-Banchero)
0C
AcidDewPoint(Haase-Borgmann)
0C
AcidDewPoint(Haase-Borgmann-Totmann)
0C
EquipmentID:V1Type:PIPVLVDescription:ValveGotoTop
Flows
Pressure
Temperature
Enthalpy
VaporFraction
Inlet
Outlet
kg/sec
506.8742 506.8742
kPa
26089.8413
25000
C
540 535.9015
kJ/kg
3291.2091 3291.2091
onaweight
basis
fraction
MainInputs
CalculationMode
Design
InletPressureMethod
AcceptIncomingPressure
PressureControlMethod
SpecifiedOutletPressure
DesiredExitPressure
24997.87 kPa
OutletPressure
25000 kPa
TemperatureControlMethod
NoEnthalpyChange
UnChecked
NoCalculations
UnChecked
DemandFlowCalculations
AuxiliaryBoilerCalculations
DisablePhaseChangeMessageFlag
Leakage
CurrentValues
ThrottleFlowRatio
CurrentAbsolutePressureDrop
-1089.841 kPa
CurrentFractionalPressureDrop
0.0418 fraction
TemperatureDrop
4.0985 C
EnthalpyChange
0 kJ/kg
HeatTransfer
0 kJ/sec
CurrentSpecificVolume
0.0118 m^3/kg
CurrentEffectiveArea
38665.48 mm^2
CurrentRestrictionFactor
Limits
MinimumFractionalPressureDrop
0 fraction
MaximumFractionalPressureDrop
0.5 fraction
UseRemoteMinimumPressureLimit
MinimumInletPressure
UnChecked
0 kPa
MinimumResidualCalculatedFlow
MaximumOperatingPressure
MaximumOperatingTemperature
0 kg/sec
0 kPa
-273.15 C