BRITISH STANDARD

Structural steel
sections

Licensed copy:Scott Wilson Holdings, 30/08/2005, Uncontrolled Copy, BSI

Part 1: Specification for hot-rolled


sections

ICS 77.140.70

BS 4-1:1993
Incorporating
Amendment No. 1

BS 4-1:1993

Committees responsible for this


British Standard
The preparation of this British Standard was entrusted by the Iron and Steel
Standards Policy Committee (ISM/-) to Technical Committee ISM/13, upon
which the following bodies were represented:

Licensed copy:Scott Wilson Holdings, 30/08/2005, Uncontrolled Copy, BSI

BEAMA Ltd.
British Constructional Steelwork Association Ltd.
British Steel Industry
Health and Safety Executive
National Association of Steel Stockholders

This British Standard, having


been prepared under the
direction of the Iron and Steel
Standards Policy Committee,
was published under the
authority of the Standards
Board and comes into effect on
15 December 1993
BSI 02-2001
First published November 1903
Second edition August 1921
Third edition March 1932
Fourth edition February 1962
Fifth edition January 1972
Sixth edition November 1980
Seventh edition December 1993
The following BSI references
relate to the work on this
standard:
Committee reference ISM/13
Draft for comment 92/45671 DC
ISBN 0 580 21637 3

Amendments issued since publication


Amd. No.

Date

Comments

10598

February 2001

Addition of Table 9 and correction to Table 8.

BS 4-1:1993

Contents
Committees responsible
Foreword

Licensed copy:Scott Wilson Holdings, 30/08/2005, Uncontrolled Copy, BSI

1
2
3
4
5
6
7

Scope
Normative reference
Designation
Tolerances on universal beams, columns and bearing piles
Mass and length tolerances for joists and channels
Tolerance on depth of section for joists and channels
Dimensions of hot-rolled structural steel sections

Table 1 Tolerances on nominal depth of joists and channels


Table 2 Universal beams
Table 3 Universal columns
Table 4 Universal bearing piles
Table 5 Joists with taper flanges
Table 6 Structural tees cut from universal beams
Table 7 Structural tees cut from universal columns
Table 8 Taper flange channels
Table 9 Parallel flange channels
List of references

BSI 02-2001

Page
Inside front cover
ii
1
1
1
1
1
1
1
1
2
5
7
8
9
12
13
14
Inside back cover

BS 4-1:1993

Foreword

Licensed copy:Scott Wilson Holdings, 30/08/2005, Uncontrolled Copy, BSI

This part of BS 4 has been prepared under the direction of the Iron and Steel
Standards Policy Committee and is a revision of BS 4-1:1980 which is withdrawn.
The major reason for this revision is to delete the requirements for tolerances on
beams, columns and bearing piles which are now contained in BS EN 10034,
published simultaneously with this standard. The opportunity has also been
taken to delete derived properties from the tables in the previous edition of this
standard.
The dimensions and masses of beams, columns and bearing piles have also been
amended slightly to correct anomalies in Table 5 to Table 7 of BS 4-1:1980.
Amendment No. 1 has been added to take into account UK requirements for
parallel flange channels.
A British Standard does not purport to include all the necessary provisions of a
contract. Users of British Standards are responsible for their correct application.
Compliance with a British Standard does not of itself confer immunity
from legal obligations.

Summary of pages
This document comprises a front cover, an inside front cover, pages i and ii,
pages 1 to 14, an inside back cover and a back cover.
The BSI copyright notice displayed in this document indicates when the
document was last issued.

ii

BSI 02-2001

BS 4-1:1993

Licensed copy:Scott Wilson Holdings, 30/08/2005, Uncontrolled Copy, BSI

1 Scope
This part of BS 4 specifies the dimensions and mass
of the following hot-rolled structural steel sections:
universal beams
universal columns
universal bearing piles
joists
structural tees cut from universal beams
structural tees cut from universal columns
taper flange channels
parallel flange channels
Mass, length and depth tolerances for taper flange
joists and channels are also given.
NOTE Dimensional, mass, length and straightness tolerances
for universal beams, columns and bearing piles are given in
BS EN 10034.

2 Normative reference
This part of BS 4 incorporates, by reference,
provisions from another publication. The normative
reference is cited at the appropriate point in the text
and the publication is given on the inside back cover.
Subsequent amendments to, or revisions of, this
publication apply to this part of BS 4 only when
incorporated in it by updating or revision.

3 Designation
A section shall be designated by the serial size in
millimetres (mm) and the mass per unit length in
kilograms per metre (kg/m).
This form of designation shall be used in any
enquiry and order.
Example
a beam of 920.5 mm 420.5 mm at 388 kg/m is
designated 914 419 388 beam.

4 Tolerances on universal beams,


columns and bearing piles
Dimensional, mass, length and straightness
tolerances on universal beams, columns and bearing
piles shall be as given in BS EN 10034.

BSI 02-2001

5 Mass and length tolerances for joists


and channels
5.1 Mass
Tolerances shall be applied to the actual mass per
unit length of the joist or channel.
The rolling tolerances shall be either:
a) 2.5 % of the actual mass per unit length; or
b) + 5 % of the actual mass per unit length where
a minimum mass per unit length is ordered.
5.2 Length
Joists or channels ordered as specified or as
exact lengths shall be supplied as follows.
a) Specified lengths. When a joist or channel is to
be cut to a specified length, it shall be cut to
within 25 mm of that length. When a
minimum length is specified, it shall be cut to
within + 50 mm of that minimum length.
0
b) Exact lengths. When a section is to be cut to an
exact length, it shall be cold sawn to
within 3.2 mm of that length.

6 Tolerance on depth of section for


joists and channels
The tolerance on the nominal depth of section shall
be as given in Table 1.
Table 1 Tolerances on nominal depth of
joists and channels
Nominal depth
Over

Up to and
including

mm

mm

Maximum permissible
variation from specified
depth
mm

mm

305

+ 3.2

0.8

305

381

+ 4.0

1.6

381

432

+ 4.8

1.6

7 Dimensions of hot-rolled structural


steel sections
The nominal dimensions of hot-rolled structural
steel sections shall be as given in Table 2 to Table 9.

BS 4-1:1993

Licensed copy:Scott Wilson Holdings, 30/08/2005, Uncontrolled Copy, BSI

Table 2 Universal beams

Section designation

Mass per
unit length

Depth
h

Width
b

Web
s

Flange
t

Root radius
r

kg/m

mm

mm

mm

mm

mm

914 419 388


914 419 343

388.0
343.3

921.0
911.8

420.5
418.5

21.4
19.4

36.6
32.0

24.1
24.1

914 305 289


914 305 253
914 305 224
914 305 201

289.1
253.4
224.2
200.9

926.6
918.4
910.4
903.0

307.7
305.5
304.1
303.3

19.5
17.3
15.9
15.1

32.0
27.9
23.9
20.2

19.1
19.1
19.1
19.1

838 292 226


838 292 194
838 292 176

226.5
193.8
175.9

850.9
840.7
834.9

293.8
292.4
291.7

16.1
14.7
14.0

26.8
21.7
18.8

17.8
17.8
17.8

762 267 197


762 267 173
762 267 147
762 267 134

196.8
173.0
146.9
133.9

769.8
762.2
754.0
750.0

268.0
266.7
265.2
264.4

15.6
14.3
12.8
12.0

25.4
21.6
17.5
15.5

16.5
16.5
16.5
16.5

686 254 170


686 254 152
686 254 140
686 254 125

170.2
152.4
140.1
125.2

692.9
687.5
683.5
677.9

255.8
254.5
253.7
253.0

14.5
13.2
12.4
11.7

23.7
21.0
19.0
16.2

15.2
15.2
15.2
15.2

610 305 238


610 305 179
610 305 149

238.1
179.0
149.1

635.8
620.2
612.4

311.4
307.1
304.8

18.4
14.1
11.8

31.4
23.6
19.7

16.5
16.5
16.5

610 229 140


610 229 125
610 229 113
610 229 101

139.9
125.1
113.0
101.2

617.2
612.2
607.6
602.6

230.2
229.0
228.2
227.6

13.1
11.9
11.1
10.5

22.1
19.6
17.3
14.8

12.7
12.7
12.7
12.7

BSI 02-2001

BS 4-1:1993

Table 2 Universal beams


Section designation

Mass per unit


length

533 210 122


533 210 109
533 210 101
533 210 92
533 210 82

122.0
109.0
101.0
92.1
82.2

544.5
539.5
536.7
533.1
528.3

211.9
210.8
210.0
209.3
208.8

12.7
11.6
10.8
10.1
9.6

21.3
18.8
17.4
15.6
13.2

12.7
12.7
12.7
12.7
12.7

Licensed copy:Scott Wilson Holdings, 30/08/2005, Uncontrolled Copy, BSI

kg/m

Depth
h
mm

Width
b

Web
s

mm

Flange
t

mm

Root radius
r

mm

mm

457 191
457 191
457 191
457 191
457 191

98
89
82
74
67

98.3
89.3
82.0
74.3
67.1

467.2
463.4
460.0
457.0
453.4

192.8
191.9
191.3
190.4
189.9

11.4
10.5
9.9
9.0
8.5

19.6
17.7
16.0
14.5
12.7

10.2
10.2
10.2
10.2
10.2

457 152
457 152
457 152
457 152
457 152

82
74
67
60
52

82.1
74.2
67.2
59.8
52.3

465.8
462.0
458.0
454.6
449.8

155.3
154.4
153.8
152.9
152.4

10.5
9.6
9.0
8.1
7.6

18.9
17.0
15.0
13.3
10.9

10.2
10.2
10.2
10.2
10.2

406 178
406 178
406 178
406 178

74
67
60
54

74.2
67.1
60.1
54.1

412.8
409.4
406.4
402.6

179.5
178.8
177.9
177.7

9.5
8.8
7.9
7.7

16.0
14.3
12.8
10.9

10.2
10.2
10.2
10.2

406 140 46
406 140 39

46.0
39.0

403.2
398.0

142.2
141.8

6.8
6.4

11.2
8.6

10.2
10.2

356 171
356 171
356 171
356 171

67
57
51
45

67.1
57.0
51.0
45.0

363.4
358.0
355.0
351.4

173.2
172.2
171.5
171.1

9.1
8.1
7.4
7.0

15.7
13.0
11.5
9.7

10.2
10.2
10.2
10.2

356 127 39
356 127 33

39.1
33.1

353.4
349.0

126.0
125.4

6.6
6.0

10.7
8.5

10.2
10.2

305 165 54
305 165 46
305 165 40

54.0
46.1
40.3

310.4
306.6
303.4

166.9
165.7
165.0

7.9
6.7
6.0

13.7
11.8
10.2

8.9
8.9
8.9

305 127 48
305 127 42
305 127 37

48.1
41.9
37.0

311.0
307.2
304.4

125.3
124.3
123.4

9.0
8.0
7.1

14.0
12.1
10.7

8.9
8.9
8.9

BSI 02-2001

BS 4-1:1993

Table 2 Universal beams

Licensed copy:Scott Wilson Holdings, 30/08/2005, Uncontrolled Copy, BSI

Section designation

Mass per unit


length

Depth
h

Width
b

Web
s

Flange
t

Root radius
r

kg/m

mm

mm

mm

mm

mm

305 102 33
305 102 28
305 102 25

32.8
28.2
24.8

312.7
308.7
305.1

102.4
101.8
101.6

6.6
6.0
5.8

10.8
8.8
7.0

7.6
7.6
7.6

254 146 43
254 146 37
254 146 31

43.0
37.0
31.1

259.6
256.0
251.4

147.3
146.4
146.1

7.2
6.3
6.0

12.7
10.9
8.6

7.6
7.6
7.6

254 102 28
254 102 25
254 102 22

28.3
25.2
22.0

260.4
257.2
254.0

102.2
101.9
101.6

6.3
6.0
5.7

10.0
8.4
6.8

7.6
7.6
7.6

203 133 30
203 133 25

30.0
25.1

206.8
203.2

133.9
133.2

6.4
5.7

9.6
7.8

7.6
7.6

203 102 23
178 102 19
152 89 16
127 76 13

23.1
19.0
16.0
13.0

203.2
177.8
152.4
127.0

101.8
101.2
88.7
76.0

5.4
4.8
4.5
4.0

9.3
7.9
7.7
7.6

7.6
7.6
7.6
7.6

NOTE 1
NOTE 2

The nominal dimensions are based on the imperial values.


The masses per metre run are derived from the cross-sectional area on the basis of 0.785 kg/cm2 per metre run.

BSI 02-2001

BS 4-1:1993

Licensed copy:Scott Wilson Holdings, 30/08/2005, Uncontrolled Copy, BSI

Table 3 Universal columns

Section designation

Mass per unit


length

Depth
h

Width
b

Web
s

Flange
t

Root radius
r

kg/m

mm

mm

mm

mm

mm

356 406 634


356 406 551
356 406 467
356 406 393
356 406 340
356 406 287
356 406 235

633.9
551.0
467.0
393.0
339.9
287.1
235.1

474.6
455.6
436.6
419.0
406.4
393.6
381.0

424.0
418.5
412.2
407.0
403.0
399.0
394.8

47.6
42.1
35.8
30.6
26.6
22.6
18.4

77.0
67.5
58.0
49.2
42.9
36.5
30.2

15.2
15.2
15.2
15.2
15.2
15.2
15.2

356 368 202


356 368 177
356 368 153
356 368 129

201.9
177.0
152.9
129.0

374.6
368.2
362.0
355.6

374.7
372.6
370.5
368.6

16.5
14.4
12.3
10.4

27.0
23.8
20.7
17.5

15.2
15.2
15.2
15.2

305 305 283


305 305 240
305 305 198
305 305 158
305 305 137
305 305 118
305 305 97

282.9
240.0
198.1
158.1
136.9
117.9
96.9

365.3
352.5
339.9
327.1
320.5
314.5
307.9

322.2
318.4
314.5
311.2
309.2
307.4
305.3

26.8
23.0
19.1
15.8
13.8
12.0
9.9

44.1
37.7
31.4
25.0
21.7
18.7
15.4

15.2
15.2
15.2
15.2
15.2
15.2
15.2

254 254 167


254 254 132
254 254 107
254 254 89
254 254 73

167.1
132.0
107.1
88.9
73.1

289.1
276.3
266.7
260.3
254.1

265.2
261.3
258.8
256.3
254.6

19.2
15.3
12.8
10.3
8.6

31.7
25.3
20.5
17.3
14.2

12.7
12.7
12.7
12.7
12.7

BSI 02-2001

BS 4-1:1993

Table 3 Universal columns


Section designation

Depth
h

Width
b

Web
s

Flange
t

Root radius
r

kg/m

mm

mm

mm

mm

mm

86
71
60
52
46

86.1
71.0
60.0
52.0
46.1

222.2
215.8
209.6
206.2
203.2

209.1
206.4
205.8
204.3
203.6

12.7
10.0
9.4
7.9
7.2

20.5
17.3
14.2
12.5
11.0

10.2
10.2
10.2
10.2
10.2

152 152 37
152 152 30
152 152 23

37.0
30.0
23.0

161.8
157.6
152.4

154.4
152.9
152.2

8.0
6.5
5.8

11.5
9.4
6.8

7.6
7.6
7.6

203 203
203 203
203 203
203 203
203 203

Licensed copy:Scott Wilson Holdings, 30/08/2005, Uncontrolled Copy, BSI

Mass per unit


length

NOTE 1
NOTE 2

The nominal dimensions are based on the imperial values.


The masses per metre run are derived from the cross-sectional area on the basis of 0.785 kg/cm2 per metre run.

BSI 02-2001

BS 4-1:1993

Licensed copy:Scott Wilson Holdings, 30/08/2005, Uncontrolled Copy, BSI

Table 4 Universal bearing piles

Section designation

Mass per
unit length

Depth
h

Width
b

Web
s

Flange
t

Root radius
r

kg/m

mm

mm

mm

mm

mm

356 368 174


356 368 152
356 368 133
356 368 109

173.9
152.0
133.0
108.9

361.4
356.4
352.0
346.4

378.5
376.0
373.8
371.0

20.3
17.8
15.6
12.8

20.4
17.9
15.7
12.9

15.2
15.2
15.2
15.2

305 305 223


305 305 186
305 305 149
305 305 126
305 305 110
305 305 95
305 305 88
305 305 79

222.9
186.0
149.1
126.1
110.0
94.9
88.0
78.9

337.9
328.3
318.5
312.3
307.9
303.7
301.7
299.3

325.7
320.9
316.0
312.9
310.7
308.7
307.8
306.4

30.3
25.5
20.6
17.5
15.3
13.3
12.4
11.0

30.4
25.6
20.7
17.6
15.4
13.3
12.3
11.1

15.2
15.2
15.2
15.2
15.2
15.2
15.2
15.2

254 254 85
254 254 71
254 254 63

85.1
71.0
63.0

254.3
249.7
247.1

260.4
258.0
256.6

14.4
12.0
10.6

14.3
12.0
10.7

12.7
12.7
12.7

203 203 54
203 203 45

53.9
44.9

204.0
200.2

207.7
205.9

11.3
9.5

11.4
9.5

10.2
10.2

NOTE 1
NOTE 2

The nominal dimensions are based on the imperial values.


The masses per metre run are derived from the cross-sectional area on the basis of 0.785 kg/cm2 per metre run.

BSI 02-2001

BS 4-1:1993

Licensed copy:Scott Wilson Holdings, 30/08/2005, Uncontrolled Copy, BSI

Table 5 Joists with taper flanges

Section designation

mm

Mass per
unit length

Depth of
section
h

Width of
section
b

kg/m

mm

mm

Thickness

Radius

Web
s

Flange
t

Root
r1

Toe
r2

mm

mm

mm

mm

254 203 82
254 114 37

82.0
37.2

254.0
254.0

203.2
114.3

10.2
7.6

19.9
12.8

19.6
12.4

9.7
6.1

203 152 52

52.3

203.2

152.4

8.9

16.5

15.5

7.6

152 127 37

37.3

152.4

127.0

10.4

13.2

13.5

6.6

127 114 29
127 114 27
127 76 16

29.3
26.9
16.5

127.0
127.0
127.0

114.3
114.3
76.2

10.2
7.4
5.6

11.5
11.4
9.6

9.9
9.9
9.4

4.8
5.0
4.6

114 114 27

26.9

114.3

114.3

9.5

10.7

14.2

3.2

102 102 23
102 44 7

23.0
7.5

101.6
101.6

101.6
44.5

9.5
4.3

10.3
6.1

11.1
6.9

3.2
3.3

89 89 19

19.5

88.9

88.9

9.5

9.9

11.1

3.2

76 76 15
76 76 13

15.0
12.8

76.2
76.2

80.0
76.2

8.9
5.1

8.4
8.4

9.4
9.4

4.6
4.6

NOTE 1
NOTE 2

The nominal dimensions are based on the imperial values.


The masses per metre run are derived from the cross-sectional area on the basis of 0.785 kg/cm2 per metre run.

BSI 02-2001

BS 4-1:1993

Table 6 Structural tees cut from universal beams

Licensed copy:Scott Wilson Holdings, 30/08/2005, Uncontrolled Copy, BSI

Section designation

Mass per
unit
length

Cut from universal


beam (see Table 2)

Width of
section
b

Depth of
section
A

Section designation
kg/m

mm

mm

mm

Thickness

Web
s

Flange
t

mm

mm

Root
radius
r

mm

305 457 127


305 457 112
305 457 101

126.7
112.1
100.4

914 305 253


914 305 224
914 305 201

305.5
304.1
303.3

459.1
455.1
451.4

17.3
15.9
15.1

27.9
23.9
20.2

19.1
19.1
19.1

292 419 113


292 419 97
292 419 88

113.2
96.9
87.9

838 292 226


838 292 194
838 292 176

293.8
292.4
291.7

425.4
420.3
417.4

16.1
14.7
14.0

26.8
21.7
18.8

17.8
17.8
17.8

267 381 99
267 381 87
267 381 74

98.3
86.5
73.4

762 267 197


762 267 173
762 267 147

268.0
266.7
265.2

384.8
381.0
376.9

15.6
14.3
12.8

25.4
21.6
17.5

16.5
16.5
16.5

254 343
254 343
254 343
254 343

85
76
70
63

85.1
76.2
70.0
62.6

686 254 170


686 254 152
686 254 140
686 254 125

255.8
254.5
253.7
253.0

346.4
343.7
341.7
338.9

14.5
13.2
12.4
11.7

23.7
21.0
19.0
16.2

15.2
15.2
15.2
15.2

305 305 119


305 305 90
305 305 75

119.0
89.5
74.6

610 305 238


610 305 179
610 305 149

311.4
307.1
304.8

317.8
310.0
306.1

18.4
14.1
11.8

31.4
23.6
19.7

16.5
16.5
16.5

69.9
62.5
56.5
50.6

610 229 140


610 229 125
610 229 113
610 229 101

230.2
229.0
228.2
227.6

308.5
306.0
303.7
301.2

13.1
11.9
11.1
10.5

22.1
19.6
17.3
14.8

12.7
12.7
12.7
12.7

229 305
229 305
229 305
229 305

BSI 02-2001

70
63
57
51

BS 4-1:1993

Table 6 Structural tees cut from universal beams


Section designation

Mass per
unit length

Cut from universal


beam (see Table 2)

Width of
section
b

Depth of
section
A

Section designation

Licensed copy:Scott Wilson Holdings, 30/08/2005, Uncontrolled Copy, BSI

kg/m

mm

mm

Thickness

Web
s

Flange
t

mm

mm

Root
radius
r

210 267 61
210 267 55
210 267 51
210 267 46
210 267 41

61.0
54.5
50.5
46.0
41.1

533 210 122


533 210 109
533 210 101
533 210 92
533 210 82

211.9
210.8
210.0
209.3
208.8

272.2
269.7
268.3
266.5
264.1

12.7
11.6
10.8
10.1
9.6

21.3
18.8
17.4
15.6
13.2

12.7
12.7
12.7
12.7
12.7

191 229 49
191 229 45
191 229 41
191 229 37
191 229 34

49.1
44.6
41.0
37.1
33.5

457 191
457 191
457 191
457 191
457 191

98
89
82
74
67

192.8
191.9
191.3
190.4
189.9

233.5
231.6
229.9
228.4
226.6

11.4
10.5
9.9
9.0
8.5

19.6
17.7
16.0
14.5
12.7

10.2
10.2
10.2
10.2
10.2

152 229 41
152 229 37
152 229 34
152 229 30
152 229 26

41.0
37.1
33.6
29.9
26.1

457 152
457 152
457 152
457 152
457 152

82
74
67
60
52

155.3
154.4
153.8
152.9
152.4

232.8
230.9
228.9
227.2
224.8

10.5
9.6
9.0
8.1
7.6

18.9
17.0
15.0
13.3
10.9

10.2
10.2
10.2
10.2
10.2

178 203 37
178 203 34
178 203 30
178 203 27

37.1
33.5
30.0
27.0

406 178
406 178
406 178
406 178

74
67
60
54

179.5
178.8
177.9
177.7

206.3
204.6
203.1
201.2

9.5
8.8
7.9
7.7

16.0
14.3
12.8
10.9

10.2
10.2
10.2
10.2

140 203 23
140 203 20

23.0
19.5

406 140 46
406 140 39

142.2
141.8

201.5
198.9

6.8
6.4

11.2
8.6

10.2
10.2

171 178 34
171 178 29
171 178 26
171 178 23

33.5
28.5
25.5
22.5

356 171
356 171
356 171
356 171

67
57
51
45

173.2
172.2
171.5
171.1

181.6
178.9
177.4
175.6

9.1
8.1
7.4
7.0

15.7
13.0
11.5
9.7

10.2
10.2
10.2
10.2

127 178 20
127 178 17

19.5
16.5

356 127 39
356 127 33

126.0
125.4

176.6
174.4

6.6
6.0

10.7
8.5

10.2
10.2

165 152 27
165 152 23
165 152 20

27.0
23.0
20.1

305 165 54
305 165 46
305 165 40

166.9
165.7
165.0

155.1
153.2
151.6

7.9
6.7
6.0

13.7
11.8
10.2

8.9
8.9
8.9

127 152 24
127 152 21
127 152 19

24.0
20.9
18.5

305 127 48
305 127 42
305 127 37

125.3
124.3
123.4

155.4
153.5
152.1

9.0
8.0
7.1

14.0
12.1
10.7

8.9
8.9
8.9

10

BSI 02-2001

BS 4-1:1993

Table 6 Structural tees cut from universal beams


Section designation

Mass per
unit
length

Cut from universal


beam (see Table 2)

Width of
section
b

Depth of
section
A

Section designation

Licensed copy:Scott Wilson Holdings, 30/08/2005, Uncontrolled Copy, BSI

kg/m

mm

mm

mm

Thickness

Web
s

Flange
t

mm

mm

Root
radius
r

mm

102 152 17
102 152 14
102 152 13

16.4
14.1
12.4

305 102 33
305 102 28
305 102 25

102.4
101.8
101.6

156.3
154.3
152.5

6.6
6.0
5.8

10.8
8.8
7.0

7.6
7.6
7.6

146 127 22
146 127 19
146 127 16

21.5
18.5
15.5

254 146 43
254 146 37
254 146 31

147.3
146.4
146.1

129.7
127.9
125.6

7.2
6.3
6.0

12.7
10.9
8.6

7.6
7.6
7.6

102 127 14
102 127 13
102 127 11

14.1
12.6
11.0

254 102 28
254 102 25
254 102 22

102.2
101.9
101.6

130.1
128.5
126.9

6.3
6.0
5.7

10.0
8.4
6.8

7.6
7.6
7.6

133 102 15
133 102 13

15.0
12.5

203 133 30
203 133 25

133.9
133.2

103.3
101.5

6.4
5.7

9.6
7.8

7.6
7.6

NOTE 1
NOTE 2

The nominal dimensions are based on the imperial values.


The masses per metre run are calculated from the cross-sectional area on the basis of 0.785 kg/cm2 per metre run.

BSI 02-2001

11

BS 4-1:1993

Table 7 Structural tees cut from universal columns

Licensed copy:Scott Wilson Holdings, 30/08/2005, Uncontrolled Copy, BSI

Section designation

Mass per
unit
length

Cut from universal beam


(see Table 2)

Width of
section
b

Depth of
section
A

Section designation
kg/m

mm

mm

mm

Thickness

Root
radius
r

Web
s

Flange
t

mm

mm

mm

406 178 118

117.5

356 406 235

394.8

190.4

18.4

30.2

15.2

368 178 101


368 178 89
368 178 77
368 178 65

100.9
88.5
76.4
64.5

356 368 202


356 368 177
356 368 153
356 368 129

374.7
372.6
370.5
368.6

187.2
184.0
180.9
177.7

16.5
14.4
12.3
10.4

27.0
23.8
20.7
17.5

15.2
15.2
15.2
15.2

305 152
305 152
305 152
305 152

79
69
59
49

79.0
68.4
58.9
48.4

305 305 158


305 305 137
305 305 118
305 305 97

311.2
309.2
307.4
305.3

163.5
160.2
157.2
153.9

15.8
13.8
12.0
9.9

25.0
21.7
18.7
15.4

15.2
15.2
15.2
15.2

254 127
254 127
254 127
254 127

66
54
45
37

66.0
53.5
44.4
36.5

254 254 132


254 254 107
254 254 89
254 254 73

261.3
258.8
256.3
254.6

138.1
133.3
130.1
127.0

15.3
12.8
10.3
8.6

25.3
20.5
17.3
14.2

12.7
12.7
12.7
12.7

203 102
203 102
203 102
203 102
203 102

43
36
30
26
23

43.0
35.5
30.0
26.0
23.0

203 203
203 203
203 203
203 203
203 203

86
71
60
52
46

209.1
206.4
205.8
204.3
203.6

111.0
107.8
104.7
103.0
101.5

12.7
10.0
9.4
7.9
7.2

20.5
17.3
14.2
12.5
11.0

10.2
10.2
10.2
10.2
10.2

152 76 19
152 76 15
152 76 12

18.5
15.0
11.5

152 152 37
152 152 30
152 152 23

154.4
152.9
152.2

80.8
78.7
76.1

8.0
6.5
5.8

11.5
9.4
6.8

7.6
7.6
7.6

NOTE 1
NOTE 2

12

The nominal dimensions are based on the imperial values.


The masses per metre run are calculated from the cross-sectional area on the basis of 0.785 kg/cm2 per metre run.

BSI 02-2001

BS 4-1:1993

Licensed copy:Scott Wilson Holdings, 30/08/2005, Uncontrolled Copy, BSI

Table 8 Taper flange channels

Section designation

Mass per
unit
length

kg/m

Depth of
section
h

mm

Width of
section
b

mm

Thickness

Radius

Depth
between
fillets
d

Web
s

Flange
t

Root
r1

Toe
r2

mm

mm

mm

mm

mm

432 102 65

65.5

431.8

101.6

12.2

16.8

15.2

4.8

362.4

381 102 55

55.0

381.0

101.6

10.4

16.3

15.2

4.8

312.4

305 102 46
305 89 42

46.2
41.8

304.8
304.8

101.6
88.9

10.2
10.2

14.8
13.7

15.2
13.7

4.8
3.2

239.2
245.4

254 89 36
254 76 28

35.7
28.2

254.0
254.0

88.9
76.2

9.1
8.1

13.6
10.9

13.7
12.2

3.2
3.2

194.7
203.8

229 89 33
229 76 26

32.7
26.1

228.6
228.6

88.9
76.2

8.6
7.6

13.3
11.2

13.7
12.2

3.2
3.2

169.8
178.0

203 89 30
203 76 24

29.8
23.9

203.2
203.2

88.9
76.2

8.1
7.1

12.9
11.2

13.7
12.2

3.2
3.2

145.2
152.5

178 89 27
178 76 21

26.8
20.8

177.8
177.8

88.9
76.2

7.6
6.6

12.3
10.3

13.7
12.2

3.2
3.2

121.0
128.8

152 89 24
152 76 18

23.9
17.9

152.4
152.4

88.9
76.2

7.1
6.4

11.6
9.0

13.7
12.2

3.2
2.4

97.0
105.9

127 64 15

14.9

127.0

63.5

6.4

9.2

10.7

2.4

84.0

102 51 10
76 38 7

10.4
6.7

101.6
76.2

50.8
38.1

6.1
5.1

7.6
6.8

9.1
7.6

2.4
2.4

65.7
45.8

NOTE 1
NOTE 2

The nominal dimensions are based on the imperial values.


The masses per metre run are calculated from the cross-sectional area on the basis of 0.785 kg/cm2 per metre run.

BSI 02-2001

13

BS 4-1:1993

Table 9 Parallel flange channels

b
Y

Licensed copy:Scott Wilson Holdings, 30/08/2005, Uncontrolled Copy, BSI

s
Section designation

Y
Mass per unit
length

Depth
h

kg/m

Width
b

mm

mm

Web
s
mm

Flange
t

Root radius
r

mm

mm

430 100 64

64.4

430

100

11.0

19.0

15

380 100 54

54.0

380

100

9.5

17.5

15

300 100 46
300 90 41

45.5
41.4

300
300

100
90

9.0
9.0

16.5
15.5

15
12

260 90 35
260 75 28

34.8
27.6

260
260

90
75

8.0
7.0

14.0
12.0

12
12

230 90 32
230 75 26

32.2
25.7

230
230

90
75

7.5
6.5

14.0
12.5

12
12

200 90 30
200 75 23

29.7
23.4

200
200

90
75

7.0
6.0

14.0
12.5

12
12

180 90 26
180 75 20

26.1
20.3

180
180

90
75

6.5
6.0

12.5
10.5

12
12

150 90 24
150 75 18

23.9
17.9

150
150

90
75

6.5
5.5

12.0
10.0

12
12

125 65 15

14.8

125

65

5.5

9.5

12

100 50 10

10.2

100

50

5.0

8.5

14

BSI 02-2001

BS 4-1:1993

List of references (see clause 2)


Normative reference

Licensed copy:Scott Wilson Holdings, 30/08/2005, Uncontrolled Copy, BSI

BS EN 10034:1993, Structural steel I and H sections Tolerances on shape and dimensions.

BSI 02-2001

Licensed copy:Scott Wilson Holdings, 30/08/2005, Uncontrolled Copy, BSI

BSI
389 Chiswick High Road
London
W4 4AL

|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|

BSI British Standards Institution


BSI is the independent national body responsible for preparing British Standards. It
presents the UK view on standards in Europe and at the international level. It is
incorporated by Royal Charter.
Revisions
British Standards are updated by amendment or revision. Users of British Standards
should make sure that they possess the latest amendments or editions.
It is the constant aim of BSI to improve the quality of our products and services. We
would be grateful if anyone finding an inaccuracy or ambiguity while using this
British Standard would inform the Secretary of the technical committee responsible,
the identity of which can be found on the inside front cover. Tel: 020 8996 9000.
Fax: 020 8996 7400.
BSI offers members an individual updating service called PLUS which ensures that
subscribers automatically receive the latest editions of standards.
Buying standards
Orders for all BSI, international and foreign standards publications should be
addressed to Customer Services. Tel: 020 8996 9001. Fax: 020 8996 7001. Standards
are also available from the BSI website at http://www.bsi-global.com.
In response to orders for international standards, it is BSI policy to supply the BSI
implementation of those that have been published as British Standards, unless
otherwise requested.
Information on standards
BSI provides a wide range of information on national, European and international
standards through its Library and its Technical Help to Exporters Service. Various
BSI electronic information services are also available which give details on all its
products and services. Contact the Information Centre. Tel: 020 8996 7111.
Fax: 020 8996 7048.
Subscribing members of BSI are kept up to date with standards developments and
receive substantial discounts on the purchase price of standards. For details of
these and other benefits contact Membership Administration. Tel: 020 8996 7002.
Fax: 020 8996 7001. Further information about BSI is available on the BSI website at
http://www.bsi-global.com.
Copyright
Copyright subsists in all BSI publications. BSI also holds the copyright, in the UK, of
the publications of the international standardization bodies. Except as permitted
under the Copyright, Designs and Patents Act 1988 no extract may be reproduced,
stored in a retrieval system or transmitted in any form or by any means electronic,
photocopying, recording or otherwise without prior written permission from BSI.
This does not preclude the free use, in the course of implementing the standard, of
necessary details such as symbols, and size, type or grade designations. If these
details are to be used for any other purpose than implementation then the prior
written permission of BSI must be obtained.
If permission is granted, the terms may include royalty payments or a licensing
agreement. Details and advice can be obtained from the Copyright Manager.
Tel: 020 8996 7070.