Академический Документы
Профессиональный Документы
Культура Документы
New
RoHS
15% lighter
(63-50 stroke)
1.31kg
New
CA2
1.54 kg
Existing model
Hexagon wrench
Cushion valve
Series CA2
CAT.ES20-222A
Air Cylinder
New
Part numbers with rod end bracket and/or pivot bracket available
Example)
Pivot bracket
Nil
None
Pivot bracket is
shipped together
with the product,
but not assembled.
D
CDA2 T 40-100Z- N
W -M9BW
Rod end bracket
Nil
None
D: Double clevis
C: Single clevis
G: Head flange
B: Basic
L: Axial foot
F: Rod flange
T: Center trunnion
L: Axial foot
(kg)
New CA2
40
50
63
80
100
0.93
1.31
1.84
3.17
4.29
Features 1
1.06
15%
1.54
14%
2.15
11%
3.56
10%
4.76
Series CA2
No substances
hazardous to the
environment are used.
Lead free bushing is used as
sliding material.
Compliant with EU RoHS
directive.
Mounting dimensions
are the same as the
existing product.
air
When starting
operation
Operating
direction
Cushion seal
Cushion ring
Stroke Variations
Standard stroke
Bore size
(mm)
20
50
75
100
125
150
175
200
250
300
350
400
450
500
600
Long stroke
(L and F only)
700
40
800
50
1200
63
80
1400
100
1500
Series Variations
Variations
Series
CA2
Standard
New
Type
Bore size
(mm)
With rod
boot
Clean
series
Catalogs
Water
resistant
Single rod
40, 50, 63
80, 100
Double rod
CA2
Standard
Best Pneumatics
Single rod
Floating Joints
Water Resistant Cylinders
Rodless Cylinders
Air-hydro Units
40, 50, 63
80, 100
Auto Switches
Ver.
Best Pneumatics
Double rod
Floating Joints
Water Resistant Cylinders
Rodless Cylinders
Air-hydro Units
Auto Switches
Ver.
CA2K
Non-rotating
rod
Best Pneumatics
Single rod
Floating Joints
Water Resistant Cylinders
Rodless Cylinders
Air-hydro Units
Auto Switches
Ver.
40, 50, 63
Best Pneumatics
Double rod
Floating Joints
Water Resistant Cylinders
Rodless Cylinders
Air-hydro Units
Auto Switches
Ver.
CA2 Y
Smooth Cylinder
Best Pneumatics
Single rod
Table Cylinders
Guide Cylinders
Lock Cylinders
Specialty Cylinders
Clamp Cylinders
Stopper Cylinders
Stroke Reading
Cylinders
Valve Mounted
Cylinders
CA2 H
Air-hydro
Shock Absorbers
Auto Switches
Ver.
CBA2
With end lock
Best Pneumatics
Double rod
Floating Joints
Water Resistant Cylinders
Rodless Cylinders
Air-hydro Units
40, 50, 63
80, 100
Auto Switches
Ver.
Best Pneumatics
Single rod
Floating Joints
Water Resistant Cylinders
Rodless Cylinders
Air-hydro Units
Auto Switches
Ver.
Double rod
Best Pneumatics
Standard Air Cylinders
Floating Joints
Water Resistant Cylinders
Rodless Cylinders
Air-hydro Units
Auto Switches
Ver.
Best Pneumatics
Page 356
Best Pneumatics
Page 368
Best Pneumatics
Page 373
Best Pneumatics
Page 377
Best Pneumatics
Page 1094
Best Pneumatics
Page 382
Best Pneumatics
Page 388
Best Pneumatics
Page 396
Features 2
Symbol
Specifications
Standard
Standard
CDA2- Z
Built-in magnet
Long st
Long stroke
CA2 - JZ
CA2 - KZ
25A-
-XA
-XC7
-XC8
-XC14
-XC15
-XC30
Rod trunnion
Front matter 1
Series
Action/
Type
Applicable
bore size
CA2
(Standard)
Double acting
Single rod
Double rod
40 to 100
40 to 100
Air Cylinder
Standard: Double Acting, Single Rod
Series CA2
RoHS
How to Order
CA2 L 50 100
With auto switch
CDA2 D 50 100
40 40 mm
50 50 mm
63 63 mm
80 80 mm
100 100 mm
Z N W M9BW
Made to Order
Bore size
(Built-in magnet)
B
L
F
G
C
D
T
Nil
Nil
Without bracket
Pivot bracket
Without bracket
Single knuckle joint
Double knuckle joint
V
W
Cylinder suffix
Nil
Without
Nylon tarpaulin
Heat resistant tarpaulin
J
K
Rod boot
Bracket 2
Bracket 1
Auto switch
Nil
Built-in Magnet
Cylinder Model
Number of
auto switches
Nil
S
3
n
2 pcs.
1 pc.
3 pcs.
n pcs.
Type
Special function
Electrical
entry
Indicator light
Applicable Auto Switches/Refer to page 1263 to 1371 in Best Pneumatics No. 2 for further information on auto switches.
Load voltage
Wiring
(Output)
DC
AC
3-wire (NPN)
5 V, 12 V
3-wire (PNP)
Grommet
24 V
12 V
2-wire
Solid state auto switch
3-wire (NPN)
2-wire
Terminal
conduit
Yes
Diagnostic indication
(2-color indication)
100 V, 200 V
12 V
3-wire (NPN)
5 V, 12 V
3-wire (PNP)
2-wire
Grommet
24 V
3-wire (NPN)
3-wire (PNP)
Water resistant
(2-color indication)
4-wire (NPN)
2-wire
(Non-polar)
3-wire
Yes (NPN equivalent)
Grommet
Terminal
conduit
DIN terminal
Diagnostic indication (2-color indication) Grommet
No
Yes
No
2-wire
12 V
12 V
24 V
12 V
M9P
G5P
M9B
K59
J51
G39C
K39C
M9NW
G39
K39
G59W
M9PW
G5PW
M9BW
K59W
IC circuit Relay,
PLC
G5BA
G59F
A96
100 V
100 V or less
100 V, 200 V
200 V or less
A93
A90
A54
A64
A33C
A34C
A44C
A59W
IC circuit
100 V, 200 V
Yes
G59
5V
F59F
P3DW
P4DW
5 V, 12 V
M9N
M9NA
M9PA
M9BA
5 V, 12 V
2-wire
B54
B64
A33
A34
A44
B59W
IC circuit
IC circuit
IC circuit
Water resistant type auto switches can be mounted on the above models, but in such case SMC cannot guarantee water resistance.
A water resistant type cylinder is recommended for use in an environment which requires water resistance.
Lead wire length symbols: 0.5m Nil (Example) M9NW
Solid state auto switches marked with are produced upon receipt of order.
1m M (Example) M9NWM
3m L (Example) M9NWL
5m Z (Example) M9NWZ
Since there are other applicable auto switches then listed above, refer to page 23 for details.
For details about auto switches with pre-wired connector, refer to pages 1328 and 1329 in Best Pneumatics No. 2.
For the D-P3DW , refer to the catalog CAT.ES20-201.
The D-A9 /M9
/P3DW auto switches are shipped together, (but not assembled). (However, auto switch mounting brackets are assembled for the
D-A9 /M9
before shipment.)
Relay,
PLC
PLC
Relay,
PLC
Series CA2
Specifications
40
50
63
Fluid
Action
1.5 MPa
1.0 MPa
0.05 MPa
Piston speed
50 to 500 mm/s
Cushion
Air cushion
Up to 250st: +1.0
251 to 1000st: +1.4
1001 to 1500st: +1.8
0
0
0
Not required (Non-lube)
Double acting
Lubrication
Mounting
Allowable kinetic When air cushion is activated
energy (J) Note 2) When air cushion is not activated
Air cushion
Made to
Order
Made to Order
Symbol
-XA
-XC7
-XC8
-XC14
-XC15
-XC30
Specifications
CDA2D50-100Z-NW-M9BW
100
Double acting
Proof pressure
JIS Symbol
80
Air
2.8
4.6
7.8
16
29
0.33
0.56
0.91
1.50
2.68
(mm)
Bore size
Standard stroke
40
800
50, 63
1200
80, 100
80: 1400
100: 1500
Intermediate strokes not listed above are produced upon receipt of order.
J
K
Nylon tarpaulin
110 C
Accessories
Mounting
Standard
Basic
Axial
foot
Rod
flange
Head
flange
Single
clevis
Double Center
clevis trunnion
Option
Caution
1. The minimum stroke for mounting varies with the auto switch type and
cylinder mounting type. In particular, the center trunnion type needs
careful attention. (For details, refer to pages 21 and 22.)
Air Cylinder
Standard: Double Acting, Single Rod
Weights/Aluminum Tube
Series CA2
40
50
63
80
100
Basic
0.73
1.06
1.53
2.73
3.71
Axial foot
40
50
63
80
100
Axial foot
0.91
1.25
1.83
3.40
4.64
Flange
Basic
Flange
1.09
1.48
2.28
4.18
5.57
Single clevis
weight
Single clevis
0.95
1.37
2.12
3.84
5.43
Double clevis
Double clevis
0.99
1.46
2.28
4.13
5.95
Trunnion
1.08
1.51
2.29
4.28
5.93
0.20
0.25
0.31
0.46
0.58
Single knuckle
0.23
0.26
0.26
0.60
0.83
0.37
0.43
0.43
0.87
1.27
Calculation:
Example) CA2L40-100Z (Axial foot type, 40, 100 stroke)
Basic weight 0.91 kg
Additional weight 0.20/50 stroke
Cylinder stroke 100 stroke
0.91 + 0.20 x 100/50 = 1.31 kg
1000
100
80
63
50
40
100
60
10
00
10
0
50
50
1
0
Accessories
10
Additional weight
per 50 mm of stroke All mounting brackets
When axial foot brackets are used, order two pieces per cylinder.
A clevis pin, flat washers and split pins are shipped together with
double clevis.
Series CA2
Construction
@1 !6 i q e r @0 y t !7 !4 !5 !9 u w
!1 !8 o
!0 !3 !2
Component Parts
No.
Description
Material
Note
Rod cover
Aluminum die-casted
Trivalent chromate
Head cover
Aluminum die-casted
Trivalent chromate
Cylinder tube
Aluminum alloy
Hard anodized
Piston rod
Carbon steel
Piston
Aluminum alloy
Cushion ring
Aluminum alloy
Anodized
Cushion ring B
Aluminum alloy
Anodized
Bushing
Cushion valve
Bearing alloy
Steel wire
Plating
10 Tie-rod
Carbon steel
11 Retaining ring
Spring steel
Phosphate coating
12 Spring washer
Steel wire
Plating
Rolled steel
Plating
13 Tie-rod nut
14 Wear ring
15 Cushion seal
Resin
Urethane
16 Rod seal
NBR
17 Piston seal
NBR
NBR
NBR
20 Piston gasket
21 Rod end nut
NBR
O-ring
Rolled steel
Plating
Bore size
(mm)
40
50
63
80
100
Kit no.
Contents
CA2-40Z-PS
CA2-50Z-PS
CA2-63Z-PS
CA2-80Z-PS
Set of nos.
above
!5, !6, !7, !9
CA2-100Z-PS
Seal kit includes !5, !6, !7, !9. Order the seal kit based on each bore size.
Do not disassemble the trunnion type. Refer to page 29.
Seal kit includes a grease pack (40, 50: 10 g, 63, 80: 20 g, 100: 30 g).
Order with the following part number when only the grease pack is needed.
Grease pack part number: GR-S-010 (10 g), GR-S-020 (20 g)
Air Cylinder
Standard: Double Acting, Single Rod
Series CA2
Basic: CA2B
2xP
2 x Cushion valve
4xJ
C
B
MM
H1
L
10.2
AL
B1
C
B
h+L
ZZ + L + Stroke
WA
WA
K
H
N
N
S + Stroke
ZZ + Stroke
(mm)
Bore size
(mm)
Stroke range
(mm)
AL
B1
H1
KA
40
50
63
80
100
Up to 500
Up to 600
Up to 600
Up to 700
Up to 700
30
35
35
40
40
27
32
32
37
37
60
70
85
102
116
22
27
27
32
41
44
52
64
78
92
16
20
20
25
30
32
40
40
52
52
10
10
10
14
14
15
17
17
21
21
8
11
11
13
16
M8 x 1.25
M8 x 1.25
M10 x 1.25
M12 x 1.75
M12 x 1.75
6
7
7
10
10
14
18
18
22
26
11
11
14
17
17
Bore size
(mm)
Stroke range
(mm)
Up to 500
Up to 600
Up to 600
Up to 700
Up to 700
MM
WA
M14 x 1.5
M18 x 1.5
M18 x 1.5
M22 x 1.5
M26 x 1.5
27
30
31
37
40
1/4
3/8
3/8
1/2
1/2
84
90
98
116
126
18.5
18.5
23
28.5
28.5
40
50
63
80
100
ZZ
ZZ
51
58
58
71
72
146
159
170
204
215
56
64
64
76
76
43
52
52
65
65
11.2
11.2
11.2
12.5
14
59
66
66
80
81
1/4 Stroke
1/4 Stroke
1/4 Stroke
1/4 Stroke
1/4 Stroke
154
167
178
213
224
Long stroke
2xP
4xJ
2 x Cushion valve
When the stroke is 1001 mm or longer,
a tie-rod reinforcement ring is attached.
10.2
RY
E
D
C
B
d
e
MM
H1
B1
C
B
h+L
ZZ + L + Stroke
AL
A
K
F
RT
S + Stroke
ZZ + Stroke
(mm)
Bore size
(mm)
40
50
63
80
100
Stroke range
(mm)
501 to 800
601 to 1200
601 to 1200
751 to 1400
751 to 1500
Bore size
(mm)
Stroke range
(mm)
MM
RT
RY
40
50
63
80
100
501 to 800
601 to 1200
601 to 1200
751 to 1400
751 to 1500
M14 x 1.5
M18 x 1.5
M18 x 1.5
M22 x 1.5
M26 x 1.5
27
30
31
37
40
1/4
3/8
3/8
1/2
1/2
30
30
40
45
50
64
76
92
112
136
84
90
98
116
126
AL
B1
H1
KA
30
35
35
40
40
27
32
32
37
37
60
70
85
102
116
22
27
27
32
41
44
52
64
78
92
16
20
20
25
30
32
40
40
52
52
10
10
10
14
14
15
17
17
21
21
8
11
11
13
16
M8 x 1.25
M8 x 1.25
M10 x 1.25
M12 x 1.75
M12 x 1.75
6
7
7
10
10
14
18
18
22
26
M
Without reinforcement ring With reinforcement ring
11
11
11
12
14
15
17
19
17
19
ZZ
ZZ
51
58
58
71
72
146
159
170
204
215
56
64
64
76
76
43
52
52
65
65
11.2
11.2
11.2
12.5
14
59
66
66
80
81
1/4 Stroke
1/4 Stroke
1/4 Stroke
1/4 Stroke
1/4 Stroke
154
167
178
213
224
Series CA2
Axial Foot: CA2L
G
H
B1
A
AL
4xJ
2 x Cushion valve
4 x LD
C
B
LH
LY
LX
C
B
h+L
ZZ + L + Stroke
LT
d
e
2xP
H1
MM
10.2
S + Stroke
LS + Stroke
ZZ + Stroke
X
Y
(mm)
Bore size
(mm)
Stroke range
(mm)
Up to 500
Up to 600
Up to 600
Up to 700
Up to 700
40
50
63
80
100
Bore size
(mm)
Stroke range
(mm)
Up to 500
Up to 600
Up to 600
Up to 700
Up to 700
40
50
63
80
100
AL
B1
H1
KA
LD
LH
LS
LT
LX
30
35
35
40
40
27
32
32
37
37
60
70
85
102
116
22
27
27
32
41
44
52
64
78
92
16
20
20
25
30
32
40
40
52
52
10
10
10
14
14
15
17
17
21
21
8
11
11
13
16
M8 x 1.25
M8 x 1.25
M10 x 1.25
M12 x 1.75
M12 x 1.75
6
7
7
10
10
14
18
18
22
26
9
9
11.5
13.5
13.5
40
45
50
65
75
138
144
166
204
212
3.2
3.2
3.2
4.5
6
42
50
59
76
92
LY
MM
70
80
93
116
133
M14 x 1.5
M18 x 1.5
M18 x 1.5
M22 x 1.5
M26 x 1.5
27
30
31
37
40
1/4
3/8
3/8
1/2
1/2
84
90
98
116
126
27
27
34
44
43
13
13
16
16
17
ZZ
ZZ
51
58
58
71
72
175
188
206
247
258
56
64
64
76
76
43
52
52
65
65
11.2
11.2
11.2
12.5
14.0
59
66
66
80
81
1/4 Stroke
1/4 Stroke
1/4 Stroke
1/4 Stroke
1/4 Stroke
183
196
214
256
267
Long stroke
G 2 x P 2 x Cushion valve
When the stroke is 1001 mm or longer, G
a tie-rod reinforcement ring is attached.
RY
4 x LD
LX
C
h+L
ZZ + L + Stroke
LT
MM H1
C
B
LH
10.2
A
AL
4xJ
LY
d
e
B1
RT
X
Y
N
X
S + Stroke
LS + Stroke
ZZ + Stroke
(mm)
Bore size
(mm)
40
50
63
80
100
Bore size
(mm)
40
50
63
80
100
Stroke range
(mm)
501 to 800
601 to 1200
601 to 1200
751 to 1400
751 to 1500
Stroke range
(mm)
501 to 800
601 to 1200
601 to 1200
751 to 1400
751 to 1500
AL
B1
H1
KA
LD
LH
LS
LT
LX
LY
30
35
35
40
40
27
32
32
37
37
60
70
85
102
116
22
27
27
32
41
44
52
64
78
92
16
20
20
25
30
32
40
40
52
52
10
10
10
14
14
15
17
17
21
21
8
11
11
13
16
M8 1.25
M8 1.25
M10 1.25
M12 1.75
M12 1.75
6
7
7
10
10
14
18
18
22
26
9
9
11.5
13.5
13.5
40
45
50
65
75
138
144
166
204
212
3.2
3.2
3.2
4.5
6
42
50
59
76
92
70
80
93
116
133
RT
RY
27
30
31
37
40
1/4
3/8
3/8
1/2
1/2
84
90
98
116
126
27
27
34
44
43
13
13
16
16
17
30
30
40
45
50
64
76
92
112
136
MM
M14
M18
M18
M22
M26
x 1.15
x 1.15
x 1.15
x 1.15
x 1.15
ZZ
51
58
58
71
72
175
188
206
247
258
56
64
64
76
76
43
52
52
65
65
ZZ
11.2
11.2
11.2
12.5
14.0
59
66
66
80
81
1/4 Stroke
1/4 Stroke
1/4 Stroke
1/4 Stroke
1/4 Stroke
183
196
214
256
267
Air Cylinder
Standard: Double Acting, Single Rod
Series CA2
2 x Cushion valve
4xJ
4 x FD
10.2
h+L
FT
ZZ + L + Stroke
C
B
FX
FZ
N
M
S + Stroke
ZZ + Stroke
H1
AL
K
FB
FV
FY
d
e
MM
(mm)
Bore size
(mm)
40
50
63
80
100
Bore size
(mm)
40
50
63
80
100
Stroke range
(mm)
Up to 500
Up to 600
Up to 600
Up to 700
Up to 700
Stroke range
(mm)
Up to 500
Up to 600
Up to 600
Up to 700
Up to 700
AL
B1
FB
FD
FT
FV
FX
FY
FZ
H1
KA
30
35
35
40
40
27
32
32
37
37
60
70
85
102
116
22
27
27
32
41
44
52
64
78
92
16
20
20
25
30
32
40
40
52
52
71
9
81
9
101 11.5
119 13.5
133 13.5
12
12
15
18
18
60
70
86
102
116
80
90
105
130
150
42
50
59
76
92
100
110
130
160
180
15
17
17
21
21
8
11
11
13
16
M8 x 1.25
M8 x 1.25
M10 x 1.25
M12 x 1.75
M12 x 1.75
6
7
7
10
10
14
18
18
22
26
MM
11
11
14
17
17
M14 x 1.5
M18 x 1.5
M18 x 1.5
M22 x 1.5
M26 x 1.5
27
30
31
37
40
1/4
3/8
3/8
1/2
1/2
84
90
98
116
126
ZZ
ZZ
51
58
58
71
72
146
159
170
204
215
52
58
58
80
80
43
52
52
65
65
15
15
17.5
21.5
21.5
59
66
66
80
81
1/4 Stroke
1/4 Stroke
1/4 Stroke
1/4 Stroke
1/4 Stroke
154
167
178
213
224
Long stroke
Width across flats KA
2 x P 2 x Cushion valve
When the stroke is 1001 mm or longer,
a tie-rod reinforcement ring is attached. G
RY
4 x FD
4xJ
C
B
FB
FY
MM
H1
L
10.2
AL
FT
h+L
ZZ + L + Stroke
RT
C
B
FX
FZ
K
H
S + Stroke
ZZ + Stroke
(mm)
Bore size
(mm)
40
50
63
80
100
Bore size
(mm)
40
50
63
80
100
Stroke range
(mm)
501 to 800
601 to 1200
601 to 1200
751 to 1400
751 to 1500
Stroke range
(mm)
501 to 800
601 to 1200
601 to 1200
751 to 1400
751 to 1500
AL
B1
FB
FD
FT
FX
FY
FZ
H1
KA
30
35
35
40
40
27
32
32
37
37
60
70
85
102
116
22
27
27
32
41
44
52
64
78
92
16
20
20
25
30
32
40
40
52
52
71
9
88
9
105 11.5
124 13.5
140 13.5
12
20
23
28
29
80
120
140
164
180
42
58
64
84
100
100
144
170
198
220
15
17
17
21
21
8
11
11
13
16
M8 x 1.25
M8 x 1.25
M10 x 1.25
M12 x 1.75
M12 x 1.75
6
7
7
10
10
14
18
18
22
26
11
6
10
12
12
MM
RT
RY
M14 x 1.5
M18 x 1.5
M18 x 1.5
M22 x 1.5
M26 x 1.5
27
30
31
37
40
1/4
3/8
3/8
1/2
1/2
30
30
40
45
50
64
76
92
112
136
84
90
98
116
126
ZZ
ZZ
51
67
71
87
89
146
163
179
215
227
52
52
52
65
65
19
19
19
21
21
66
66
66
80
81
1/4 Stroke
1/4 Stroke
1/4 Stroke
1/4 Stroke
1/4 Stroke
162
162
174
208
219
Series CA2
Head Flange: CA2G
4 x FD
4xJ
B1
2xP
2 x Cushion valve
C
B
FB
FV
FY
MM
H1
10.2
AL
C
B
FX
FZ
h+L
ZZ + L + Stroke
A
H
S + Stroke
ZZ + Stroke
FT
(mm)
Bore size
(mm)
Stroke range
(mm)
Up to 500
Up to 600
Up to 600
Up to 700
Up to 700
40
50
63
80
100
Stroke range
(mm)
Up to 500
Up to 600
Up to 600
Up to 700
Up to 700
Bore size
(mm)
40
50
63
80
100
AL
B1
FB
FD
FT
FV
FX
FY
FZ
H1
30
35
35
40
40
27
32
32
37
37
60
70
85
102
116
22
27
27
32
41
44
52
64
78
92
16
20
20
25
30
32
40
40
52
52
10
10
10
14
14
71
81
101
119
133
9
9
11.5
13.5
13.5
12
12
15
18
18
60
70
86
102
116
80
90
105
130
150
42
50
59
76
92
100
110
130
160
180
15
17
17
21
21
8
11
11
13
16
M8 x 1.25
M8 x 1.25
M10 x 1.25
M12 x 1.75
M12 x 1.75
KA
MM
6
7
7
10
10
14
18
18
22
26
M14 x 1.5
M18 x 1.5
M18 x 1.5
M22 x 1.5
M26 x 1.5
27
30
31
37
40
1/4
3/8
3/8
1/2
1/2
84
90
98
116
126
ZZ
ZZ
51
58
58
71
72
147
160
171
205
216
56
64
64
76
76
43
52
52
65
65
11.2
11.2
11.2
12.5
14.0
59
66
66
80
81
1/4 Stroke
1/4 Stroke
1/4 Stroke
1/4 Stroke
1/4 Stroke
155
168
179
214
225
2 x Cushion valve
C
B
d
e
Width
across flats B1
10.2
4xJ
CDH10
MM
H1
AL
CX
h+L
ZZ + L + Stroke
S + Stroke
Z + Stroke
ZZ + Stroke
RR
(mm)
Bore size
(mm)
40
50
63
80
100
Bore size
(mm)
40
50
63
80
100
Stroke range
(mm)
Up to 500
Up to 600
Up to 600
Up to 700
Up to 700
Stroke range
(mm)
Up to 500
Up to 600
Up to 600
Up to 700
Up to 700
AL
30
35
35
40
40
27
32
32
37
37
B1
CDH10
+0.058
0
+0.070
0
+0.070
0
+0.084
0
+0.084
0
CX
H1
KA
15 0.1
0.3
18 0.1
0.3
25 0.1
0.3
31.5 0.1
0.3
35.5 0.1
0.3
16
20
20
25
30
32
40
40
52
52
10
10
10
14
14
15
17
17
21
21
8
11
11
13
16
M8 x 1.25
M8 x 1.25
M10 x 1.25
M12 x 1.75
M12 x 1.75
6
7
7
10
10
14
18
18
22
26
30
35
40
48
58
60
70
85
102
116
22
27
27
32
41
44
52
64
78
92
10
12
16
20
25
MM
RR
ZZ
M14 x 1.5
M18 x 1.5
M18 x 1.5
M22 x 1.5
M26 x 1.5
27
30
31
37
40
1/4
3/8
3/8
1/2
1/2
10
12
16
20
25
84
90
98
116
126
16
19
23
28
36
51
58
58
71
72
165
183
196
235
256
175
195
212
255
281
56
64
64
76
76
43
52
52
65
65
11.2
11.2
11.2
12.5
14.0
ZZ
59
66
66
80
81
1/4 Stroke
1/4 Stroke
1/4 Stroke
1/4 Stroke
1/4 Stroke
173
191
204
244
265
183
203
220
264
290
Air Cylinder
Standard: Double Acting, Single Rod
Series CA2
2xP
2 x Cushion valve
4xJ
d
e
MM
H1
10.2
Width
across flats B1
h+L
ZZ + L + Stroke
AL
A
K
F
CX
S + Stroke
CZ
C
B
Z + Stroke
ZZ + Stroke
RR
(mm)
A pin and retaining rings are shipped together with double clevis and/or double knuckle joint.
Bore size
(mm)
Stroke range
(mm)
Up to 500
Up to 600
Up to 600
Up to 700
Up to 700
40
50
63
80
100
Bore size
(mm)
Stroke range
(mm)
Up to 500
Up to 600
Up to 600
Up to 700
Up to 700
40
50
63
80
100
AL
B1
CDH10
+0.058
0
+0.070
0
+0.070
0
+0.084
0
+0.084
0
CX
CZ
H1
KA
15 +0.3
+0.1
18 +0.3
+0.1
25 +0.3
+0.1
31.5 +0.3
+0.1
35.5 +0.3
+0.1
29.5
38
49
61
64
16
20
20
25
30
32
40
40
52
52
10
10
10
14
14
15
17
17
21
21
8
11
11
13
16
M8 x 1.25
M8 x 1.25
M10 x 1.25
M12 x 1.75
M12 x 1.75
6
7
7
10
10
14
18
18
22
26
30
35
40
48
58
60
70
85
102
116
22
27
27
32
41
44
52
64
78
92
10
12
16
20
25
MM
RR
ZZ
M14 x 1.5
M18 x 1.5
M18 x 1.5
M22 x 1.5
M26 x 1.5
27
30
31
37
40
1/4
3/8
3/8
1/2
1/2
10
12
16
20
25
84
90
98
116
126
16
19
23
28
36
51
58
58
71
72
165
183
196
235
256
175
195
212
255
281
56
64
64
76
76
43
52
52
65
65
11.2
11.2
11.2
12.5
14.0
30
35
35
40
40
27
32
32
37
37
ZZ
59
66
66
80
81
1/4 Stroke
1/4 Stroke
1/4 Stroke
1/4 Stroke
1/4 Stroke
173
191
204
244
265
183
203
220
264
290
B1
Z + 1/2 Stroke
G
4xJ
2xP
TDe8
MM
TY
d
e
2 x Cushion valve
H1
10.2
AL
A
C
B
TX
TZ
h+L
ZZ + L + Stroke
K
F
TT
S + Stroke
ZZ + Stroke
(mm)
Bore size
(mm)
40
50
63
80
100
Stroke range
(mm)
Up to 500
Up to 600
Up to 600
Up to 700
Up to 700
Bore size
(mm)
Stroke range
(mm)
40
50
63
80
100
Up to 500
Up to 600
Up to 600
Up to 700
Up to 700
AL
B1
H1
KA
MM
30
35
35
40
40
27
32
32
37
37
60
70
85
102
116
22
27
27
32
41
44
52
64
78
92
16
20
20
25
30
32
40
40
52
52
10
10
10
14
14
15
17
17
21
21
8
11
11
13
16
M8 x 1.25
M8 x 1.25
M10 x 1.25
M12 x 1.75
M12 x 1.75
6
7
7
10
10
14
18
18
22
26
M14 x 1.5
M18 x 1.5
M18 x 1.5
M22 x 1.5
M26 x 1.5
27
30
31
37
40
1/4
3/8
3/8
1/2
1/2
84
90
98
116
126
TDe8
TT
TX
TY
TZ
ZZ
15 0.032
0.059
15 0.032
0.059
18 0.032
0.059
25 0.040
0.073
25 0.040
0.073
22
22
28
34
40
85
95
110
140
162
62
74
90
110
130
117
127
148
192
214
51
58
58
71
72
93
103
107
129
135
140
154
162
194
206
56
64
64
76
76
43
52
52
65
65
11.2
11.2
11.2
12.5
14.0
ZZ
59
66
66
80
81
1/4 Stroke
1/4 Stroke
1/4 Stroke
1/4 Stroke
1/4 Stroke
101
111
115
138
144
148
162
170
203
215
Series CA2
Trunnion and Double Clevis Pivot Bracket
Strength is the same as cylinder brackets.
Applicable Series
Bore size
Bracket type
Applicable series
CA2
CA2
Description
CA2 50
CA2 63
CA2-S04
CA2-B04
CA2-B05
CA2-B06
CA2-B08
CA2-B10
4 x TT
TX
4 x TR
Z + 1/2 Stroke
TO
TF
TH
TS
TD
TY
TO
CA2 100
MB-S10
TE
CA2 80
CA2-S06
CA2 40
TY
TU
TC
TL
TU
TA
(mm)
Part no.
Bore size
(mm)
40
50
63
80
100
CA2-S04
CA2-S06
MB-S10
TA
TL
TU
TC
TX
TE
TO
TR
TT
TS
TH
TF
TY
TD-H10 (Hole)
80
60
10
102
85
119
17
17
12
45
60
62
93
15 +0.070
0
80
60
10
112
95
129
17
17
12
45
60
74
103
15 +0.070
0
100
70
15
130
110
150
20
11
22
14
55
73
90
107
18 +0.070
0
120
90
15
166
140
192
26
13.5
24
17
75
100
110
129
25 +0.084
0
120
90
15
188
162
214
26
13.5
24
17
75
100
130
135
25 +0.084
0
4 x DT
90
4 x DR
A + B + 90
40 to 100
12
60
162
DO
DU
Rotating Angle
Bore size (mm)
DF
DH
DS
D
D
Z + Stroke
DL
DA
DU
DC
DE
(mm)
Part no.
Bore size
(mm)
CA2-B04
CA2-B05
CA2-B06
CA2-B08
CA2-B10
40
50
63
80
100
10
DA
DL
DU
DC
DX
DE
DO
DR
DT
DS
DH
DF
DDH10 (Hole)
57
35
11
65
15
85
10
17
40
52
60
165
10 +0.058
0
57
35
11
65
18
85
10
17
40
52
70
183
12 +0.070
0
67
40
13.5
80
25
105
12.5
11
22
10
50
66
85
196
16 +0.070
0
93
60
16.5
100
31.5
130
15
13.5
24
12
65
90
102
235
20 +0.084
0
93
60
16.5
100
35.5
130
15
13.5
24
12
65
90
116
256
25 +0.084
0
DO
Series CA2
Dimensions of Accessories
Y Type Double Knuckle Joint
Shaft diameter: NDH10
Hole diameter: NDd9
Cotter pin
Flat washer: Polished round
MM
Applicable
Part no. bore size
NX
NZ
L
E1
Polished
round 12
A1 E1 D1 L1
MM
R1 U1 ND NX
NZ L
Polished
Y-05D 50, 63 27 28 14 60 M18 x 1.5 15 27 12 16 +0.1 38 55.5 3 x 18L round 12
+0.3
D1
A1
Flat washer
size
+0.3
40
Y-04D
(mm)
Split pin
size
U1
Polished
round 18
+0.3
Y-08D
80
Y-10D
100
L1
1
RR
+0.3
Polished
round 20
4 x 30L
Part no.
Clevis
Knuckle
CDP-2A
40
Dd9
10
CDP-3A
50
CDP-4A
63
40, 50, 63 12
16
CDP-5A
80
18
CDP-6A
80
100
20
CDP-7A
100
25
0.040
0.076
0.050
0.093
0.050
0.093
0.050
0.093
0.065
0.117
0.065
0.117
d
Drill through
Included
split pin
Included
flat washer
3 x 18L
Polished round 10
47.5
3 x 18L
Polished round 12
61
4 x 25L
Polished round 16
76.5
66.5
4 x 25L
Polished round 18
83
73
4 x 30L
Polished round 20
88
78
4 x 36L
Polished round 24
L1
L2
46
38
55.5
71
RR
(mm)
MM
M14 x 1.5
M18 x 1.5
M22 x 1.5
M26 x 1.5
R1 U1
15.5
15.5
22.5
24.5
20
20
26
28
NDH10
12 +0.070
0
12 +0.070
0
18 +0.070
0
20 +0.084
0
NX
16
16
28
30
0.1
0.3
0.1
0.3
0.1
0.3
0.1
0.3
NT-04
NT-05
NT-08
NT-10
40
50, 63
80
100
(mm)
M14 x 1.5
M18 x 1.5
M22 x 1.5
M26 x 1.5
8
11
13
16
22
27
32
41
25.4
31.2
37.0
47.3
21
26
31
39
11
Air Cylinder
Standard: Double Acting, Double Rod
Series CA2W
40, 50, 63, 80, 100
RoHS
How to Order
CA2W L 50 100
With auto switch
Z
Z M9BW
CDA2W L 50 100
Basic
Axial foot
Rod flange
Center trunnion
Nil
One end
rod boot
Both ends
rod boot
Cylinder suffix
Made to Order
40 40 mm
50 50 mm
63 63 mm
80 80 mm
100 100 mm
Mounting
B
L
F
T
Auto switch
Bore size
Double rod
(Built-in magnet)
J
K
Nil
JJ
KK
Number of
auto switches
Nil
2 pcs.
1 pc.
3 pcs.
n pcs.
S
3
n
Type
Special function
Electrical
entry
ndicator light
Applicable Auto Switches/Refer to page 1263 to 1371 in Best Pneumalics No. 2 for further information on auto switches.
Load voltage
Wiring
(Output)
DC
3-wire (NPN)
5 V,12 V
3-wire (PNP)
Grommet
24 V
12 V
2-wire
3-wire (NPN)
2-wire
Terminal
conduit
Yes
Diagnostic indication
(2-color indication)
100 V, 200 V
12 V
5 V,12 V
3-wire(PNP)
Grommet
Water resistant
(2-color indication)
With diagnostic output (2-color indication)
Magnetic field resistant
(2-color indication)
Reed auto switch
3-wire (NPN)
2-wire
Yes
Grommet No
Yes
No
Terminal
conduit
DIN terminal
Diagnostic indication (2-color indication) Grommet
24 V
12 V
3-wire (NPN)
3-wire (PNP)
5 V,12 V
2-wire
12 V
4-wire (NPN)
2-wire
(Non-polar)
5 V,12 V
2-wire
24 V
5V
12 V
G59
M9P
G5P
M9B
K59
J51
G39C
K39C
M9NW
G39
K39
G59W
M9PW
G5PW
K59W
100 V
100 V or less
100 V, 200 V
200 V or less
F59F
P3DW
P4DW
A96
A93
A90
A54
A64
A33C
A34C
A44C
A59W
IC circuit
M9BW
100 V, 200 V
Yes
M9N
Band
mounting
M9NA
M9PA
M9BA
Tie-rod
mounting
IC circuit Relay,
PLC
G5BA
G59F
B54
B64
A33
A34
A44
B59W
IC circuit
IC circuit
IC circuit
Water resistant type auto switches can be mounted on the above models, but in such case SMC cannot guarantee water resistance.
A water-resistant type cylinder is recommended for use in an environment which requires water resistance.
Lead wire length symbols: 0.5 mNil (Example) M9NW
Solid state auto switches marked with are produced upon receipt of order.
1 m M (Example) M9NWM
3 m L (Example) M9NWL
5 m Z (Example) M9NWZ
Since there are other applicable auto switches then listed above, refer to page 23 for details.
For details about auto switches with pre-wired connector, refer to pages 1328 and 1329 in Best Pneumatics No. 2.
For the D-P3DW , refer to the catalog CAT.ES20-201.
The D-A9 /M9
/P3DW auto switches are shipped together, (but not assembled). (However, auto switch mounting brackets are assembled for the D-A9 /M9
before shipment.)
12
Relay,
PLC
PLC
Relay,
PLC
Air Cylinder
Standard: Double Acting, Double Rod
Series CA2W
Specifications
40
50
63
Fluid
Action
100
Double acting
Proof pressure
1.5 MPa
1.0 MPa
0.08 MPa
Piston speed
50 to 500 mm/s
Without auto switch: 10 to 70 C
With auto switch: 10 to 60 C
Air cushion
st +1.0
Up to 250 :
251 to 750st:
+1.4
0
Lubrication
Mounting
JIS Symbol
80
Air
With no freezing
For model with auto switch, also refer to Minimum Strokes for
(mm)
Air cushion
Bore size
40
Made to
Order
Symbol
Made to Order
-XA
-XC7
Minimum Stroke
for Auto Switch Mounting
50, 63
80, 100
25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500
25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600
25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700
Intermediate strokes not listed above are produced upon receipt of order.
J
K
Nylon tarpaulin
70 C
110 C
Accessories
Caution
1. The minimum stroke for mounting
varies with the auto switch type
and cylinder mounting type. In
particular, the center trunnion type
needs careful attention.
(For details, refer to pages 21 and
22.)
Standard stroke
Mounting
Standard
Basic
Foot
Center
Flange trunnion
Option
The above brackets have the same dimensions as those for the standard
double acting single rod CA2 series. Refer to page 11.
40
50
63
80
Bore size (mm)
Aluminum tube 0.92
Basic
1.38
1.86
3.32
Aluminum tube 1.11
Axial foot
1.6
2.19
3.99
Basic
weight
Aluminum tube 1.29
Flange
1.83
2.65
4.77
Aluminum tube 1.28
Trunnion
1.86
2.66
4.87
Additional weight All mounting
Aluminum tube 0.28
0.37
0.44
0.66
per 50 mm of stroke brackets
0.23
0.26
0.26
0.60
Single knuckle
Accessories
0.37
0.43
0.43
0.87
Double knuckle (with pin)
Calculation: (Example) CA2WL40-100Z (Axial foot type, 40, 100 stroke)
Basic weight 1.18 (Axial foot type, 40)
Additional weight 0.28/50 stroke
Cylinder stroke 100 stroke
1.18 + 0.28 x 100/50 = 1.74 kg
100
4.55
5.54
6.47
6.83
0.86
0.83
1.27
13
Series CA2W
Construction
!9
!4 u
q w e y !8 t !5 !3 !7
!0 !6 i
o !2 !1
Component Parts
No.
Description
Material
Qty.
Note
Aluminum die-casted
Trivalent chromate
2 Cylinder tube
Aluminum alloy
Hard anodized
3 Piston rod A
Carbon steel
4 Piston rod B
Carbon steel
5 Piston
Aluminum alloy
6 Cushion ring
Aluminum alloy
Bearing alloy
1 Rod cover
7 Bushing
8 Cushion valve
Anodized
Steel wire
Plating
9 Tie-rod
Carbon steel
10 Retaining ring
Spring steel
Phosphate coating
11 Spring washer
Steel wire
Plating
Rolled steel
Plating
Urethane
14 Rod seal
NBR
15 Piston seal
NBR
NBR
NBR
18 Piston gasket
NBR
O-ring
Rolled steel
Plating
12 Tie-rod nut
13 Cushion seal
14
Bore size
(mm)
40
50
63
80
100
Kit no.
Air cylinder
Contents
CA2W40Z-PS
CA2W50Z-PS
CA2W63Z-PS
CA2W80Z-PS
Set of nos.
above
!3, !4, !5, !7
CA2W100Z-PS
Air Cylinder
Standard: Double Acting, Double Rod
Series CA2W
Basic: CA2WB
Width across
flats KA
2xP
Width across
flats KA
2 x Cushion valve
MM
D
MM
H1
4xJ
H1
B1
AL
AL
K
S + Stroke
H + Stroke
ZZ + 2 x Stroke
10.2
h+L
10.2
L + Stroke
10.2
h + L + Stroke
S + Stroke
h+L
ZZ + L + Stroke
ZZ + 2L + 2 x Stroke
(mm)
Bore size
(mm)
40
50
63
80
100
Bore size
(mm)
40
50
63
80
100
Stroke range
(mm)
Up to 500
Up to 600
Up to 600
Up to 750
Up to 750
Stroke range
(mm)
Up to 500
Up to 600
Up to 600
Up to 750
Up to 750
AL
B1
H1
KA
MM
30
35
35
40
40
27
32
32
37
37
60
70
85
102
116
22
27
27
32
41
44
52
64
78
92
16
20
20
25
30
32
40
40
52
52
10
10
10
14
14
15
17
17
21
21
8
11
11
13
16
M8 x 1.25
M8 x 1.25
M10 x 1.25
M12 x 1.75
M12 x 1.75
6
7
7
10
10
14
18
18
22
26
11
11
14
17
17
M14 x 1.5
M18 x 1.5
M18 x 1.5
M22 x 1.5
M26 x 1.5
27
30
31
37
40
1/4
3/8
3/8
1/2
1/2
84
90
98
116
126
ZZ
51
58
58
71
72
186
206
214
258
270
56
64
64
76
76
43
52
52
65
65
ZZ
11.2
11.2
11.2
12.5
14.0
59
66
66
80
81
1/4 Stroke
1/4 Stroke
1/4 Stroke
1/4 Stroke
1/4 Stroke
194
214
222
267
279
(Both sides)
ZZ
202
222
230
276
288
15
Series CA2W
Axial Foot: CA2WL
G
G
H1
MM
D
4 x LD
LX
S + Stroke
LS + Stroke
LT
AL
2 x Cushion valve
MM H1
LH
2xP
AL
4xJ
LY
A
B1
H + Stroke
ZZ + 2 x Stroke
10.2
h+L
ZZ + L + 2 Stroke
(mm)
Bore size
(mm)
40
50
63
80
100
Bore size
(mm)
40
50
63
80
100
Stroke range
(mm)
Up to 500
Up to 600
Up to 600
Up to 750
Up to 750
Stroke range
(mm)
Up to 500
Up to 600
Up to 600
Up to 750
Up to 750
AL
B1
H1
KA
LD
LH
LS
LT
LX
30
35
35
40
40
27
32
32
37
37
60
70
85
102
116
22
27
27
32
41
44
52
64
78
92
16
20
20
25
30
32
40
40
52
52
10
10
10
14
14
15
17
17
21
21
8
11
11
13
16
M8 x 1.25
M8 x 1.25
M10 x 1.25
M12 x 1.75
M12 x 1.75
6
7
7
10
10
14
18
18
22
26
9
9
11.5
13.5
13.5
40
45
50
65
75
138
144
166
204
212
3.2
3.2
3.2
4.5
6
42
50
59
76
92
LY
MM
70
80
93
116
133
M14 x 1.5
M18 x 1.5
M18 x 1.5
M22 x 1.5
M26 x 1.5
27
30
31
37
40
1/4
3/8
3/8
1/2
1/2
84
90
98
116
126
27
27
34
44
43
13
13
16
16
17
ZZ
ZZ
51
58
58
71
72
186
206
214
258
270
56
64
64
76
76
43
52
52
65
65
11.2
11.2
11.2
12.5
14.0
59
66
66
80
81
1/4 Stroke
1/4 Stroke
1/4 Stroke
1/4 Stroke
1/4 Stroke
194
214
222
267
279
16
(Both sides)
ZZ
202
222
230
276
288
Air Cylinder
Standard: Double Acting, Double Rod
Series CA2W
4xJ
B1
2xP
Width across
flats KA
2 x Cushion valve
MM
D
FY
FV
FB
MM
H1
C
Width across
flats B1
B
FX
H1
AL
FT
AL
FZ
4 x FD
N
H
N
S + Basic type
A
H + Stroke
ZZ + 2 x Stroke
10.2
h+L
ZZ + L + Stroke
(mm)
Bore size
(mm)
40
50
63
80
100
Bore size
(mm)
40
50
63
80
100
Stroke range
(mm)
Up to 500
Up to 600
Up to 600
Up to 750
Up to 750
Stroke range
(mm)
Up to 500
Up to 600
Up to 600
Up to 750
Up to 750
AL
B1
FB FD
FT
FV
FX
FY
FZ
H1
KA
30
35
35
40
40
27
32
32
37
37
60
70
85
102
116
22
27
27
32
41
44
52
64
78
92
16
20
20
25
30
32
40
40
52
52
71
9
81
9
101 11.5
119 13.5
133 13.5
12
12
15
18
18
60 80
70 90
86 105
102 130
116 150
42
50
59
76
92
100
110
130
160
180
15
17
17
21
21
8
11
11
13
16
M8 x 1.25
M8 x 1.25
M10 x 1.25
M12 x 1.75
M12 x 1.75
6
7
7
10
10
14
18
18
22
26
11
11
14
17
17
MM
M14 x 1.5
M18 x 1.5
M18 x 1.5
M22 x 1.5
M26 x 1.5
27
30
31
37
40
1/4
3/8
3/8
1/2
1/2
84
90
98
116
126
ZZ
51
58
58
71
72
186
206
214
258
270
52
58
58
80
80
ZZ
43
52
52
65
65
15
15
17.5
21.5
21.5
59
66
66
80
81
1/4 Stroke
1/4 Stroke
1/4 Stroke
1/4 Stroke
1/4 Stroke
194
214
222
267
279
(Both sides)
ZZ
202
222
230
276
288
17
Series CA2W
Center Trunnion: CA2WT
Z + 1/2 Stroke
Width across
flats KA
G
E
TDe8
TY
2 x Cushion valve
2xP
Width across
G
MM flats KA
4xJ
MM
B1
AL
C
B
H1
K
A
TX
F
H
TZ
TT
S + Stroke
H1
AL
H + Stroke
ZZ + 2 x Stroke
10.2
h+L
ZZ + L + Stroke
(mm)
Bore size
(mm)
40
50
63
80
100
Bore size
(mm)
40
50
63
80
100
Stroke range
(mm)
Up to 500
Up to 600
Up to 600
Up to 750
Up to 750
Bore size
(mm)
Up to 500
Up to 600
Up to 600
Up to 750
Up to 750
AL
B1
H1
KA
MM
TDe8
30
35
35
40
40
27
32
32
37
37
60
70
85
102
116
22
27
27
32
41
44
52
64
78
92
16
20
20
25
30
32
40
40
52
52
10
10
10
14
14
15
17
17
21
21
8
11
11
13
16
M8 x 1.25
M8 x 1.25
M10 x 1.25
M12 x 1.75
M12 x 1.75
6
7
7
10
10
14
18
18
22
26
M14 x 1.5
M18 x 1.5
M18 x 1.5
M22 x 1.5
M26 x 1.5
27
30
31
37
40
1/4
3/8
3/8
1/2
1/2
84
90
98
116
126
15 0.032
0.059
15 0.032
0.059
18 0.032
0.059
25 0.040
0.073
25 0.040
0.073
TT
TX
TY
TZ
22
22
28
34
40
85 62 117
95 74 127
110 90 148
140 110 192
162 130 214
ZZ
51
58
58
71
72
93
103
107
129
135
186
206
214
258
270
56
64
64
76
76
43
52
52
65
65
ZZ
11.2
11.2
11.2
12.5
14.0
59
66
66
80
81
1/4 Stroke
1/4 Stroke
1/4 Stroke
1/4 Stroke
1/4 Stroke
101
111
115
138
144
194
214
222
267
279
18
(Both sides)
ZZ
101
111
115
138
144
202
222
230
276
288
Series CA2
<Tie-rod mounting>
D-B5 /B64/B59W
D-A9
D-M9
D-M9
D-M9
Hs
Auto switch
/A9 V
/M9 V
W/M9 WV
A/M9 AV
20
D-A3
D-G39/K39
A
Ht
33
49
G1/2
(Applicable cable O.D.) 6.8 to 9.6
Hs
Auto switch
Hs
56
34
Ht
36
D-A5 /A6
D-A59W
Ht
Hs
Auto switch
Ht
24.5
D-Z7 /Z80
D-Y59 /Y69 /Y7P/Y7PV
D-Y7 W/Y7 WV
D-Y7BA
33
D-A3 C
D-G39C/K39C
D-G5BAL
D-G59F/G5NTL
A
Hs
33
D-A44
14
24.5
Auto switch
G1/2
(Applicable cable O.D.) 6.8 to 9.6
49
36
HW
Hs
D-G5 /K59
D-G5 W/K59W
G1/2
(Applicable cable O.D.) 6.8 to 11.5
D-F5 /J5
D-F5NT
D-F5 W/J59W
D-F5BA/F59F
Hs
Auto switch
56
Ht
Ht
Hs
D-A44C
A 49.5
36
G1/2
(Applicable cable O.D.) 6.8 to 11.5
HW
Hs
D-P3DW
A
29
Hs
Auto switch
Ht
49.5
30
D-P4DW
Auto switch
32
Hs
B
Ht
36
19
Series CA2
D-M9
D-M9
D-M9
D-M9
D-M9
Bore size
(mm)
40
50
63
80
100
V
W
WV
A
AV
D-A9
D-A9 V
D-J51
D-Y59
D-Y69
D-Y7P
D-Y7PV
D-Y7 W
D-Y7 WV
D-Y7BA
D-Z7
D-Z80
D-B59W
A
B
(mm)
D-P3DW
D-P4DW
D-F5
D-J59
D-F59F
D-F5 W
D-J59W
D-F5BA
D-A59W
D-G39
D-G39C
D-K39
D-K39C
D-A5
D-A6
D-A3
D-A3 C
D-A44
D-A44C
A
B
D-F5NT
D-G5
D-K59
D-G5NT
D-G5 W
D-K59W
D-G5BA
D-G59F
A
D-B5
D-B64
2.5
2.5
4.5
4.5
5.5
5.5
10.5
10.5
9.5
8.5
5.5
4.5
2.5
1.5
3.5
2.5
11
10
1.5
0.5
12.5
11.5
8.5
7.5
2.5
5.5
4.5
6.5
5.5
14
13
2.5
1.5
4.5
3.5
16.5
13.5
12.5
9.5
10
7.5
9.5
6.5
13
10
10.5
7.5
18
15
6.5
3.5
8.5
5.5
18
16
14
11.5
9.5
6.5
14.5
12.5
12
19.5
17.5
10
8.5
6.5
12
11
10
Note) Adjust the auto switch after confirming the operating conditions in the actual setting.
20
(mm)
D-F5
D-J59
D-A5
D-F5 W D-A3 C
D-A44 D-A6
D-J59W D-G39C D-A44C
D-A59W D-F5BA D-K39C
D-F59F
D-F5NT
Hs
Hs Ht Hs Ht Hs Ht Hs Ht
81.5
38.5 31.5 38
31.5
73
69
81
69
86.5
42
35.5
78.5
77
86.5
77
93.5
46.5 43
47
43
85.5
91
93.5
102
53.5 51
53.5 51
112.5
61.5 57.5 61
35.5 42
91
94
107 102
107
57.5 104
121 112
121
Series CA2
D-A9
Number of
auto switches
2 (Different surfaces
and same surface) 1
n
D-A9 V
2 (Different surfaces
and same surface) 1
n
D-M9
D-M9 W
D-M9 V
D-M9 WV
D-M9 A
2 (Different surfaces
and same surface) 1
n
2 (Different surfaces
and same surface) 1
n
2 (Different surfaces
and same surface) 1
n
D-M9 AV
2 (Different surfaces
and same surface) 1
n
D-A5 /A6
D-F5 /J5
D-F5 W/J59W
D-F5BA/F59F
2 (Different surfaces
and same surface) 1
n (Same surface)
2 (Different surfaces
and same surface) 1
D-A59W
n (Same surface)
1
D-F5NT
2 (Different surfaces
and same surface) 1
n (Same surface)
D-B5 /B64
D-G5 /K59
D-G5 W
D-K59W
D-G5BA
D-G59F
D-G5NT
Different surfaces
Same surface
Different surfaces
Same surface
1
Different surfaces
Same surface
D-B59W
Different surfaces
Same surface
1
Different surfaces
Same surface
D-A3
D-G39
D-K39
Different surfaces
Same surface
1
Center trunnion
40
50
75
63
80
100
80
85
90
(n 2)
15 + 40
2
(n 4)
75 + 40
2
(n 4)
80 + 40 2
(n 4)
85 + 40 2
(n = 2, 4, 6, 8)
(n = 4, 8, 12, 16)
(n = 4, 8, 12, 16)
(n = 4, 8, 12, 16)
10
10 + 30
(n 2)
2
(n = 2, 4, 6, 8)
15
15 + 40
(n 2)
2
(n = 2, 4, 6, 8)
55
50
50 + 30
(n 4)
2
(n = 4, 8, 12, 16)
(n 4)
2
(n = 4, 8, 12, 16)
(n 4)
2
(n = 4, 8, 12, 16)
85 + 40
60 + 30
65
(n 4)
2
65 + 30
(n = 4, 8, 12, 16)
(n = 4, 8, 12, 16)
90 + 40
(n 4)
2
(n = 4, 8, 12, 16)
90
(n 4)
2
(n 4)
2
(n = 4, 8, 12, 16)
60
85
80
80 + 40
55 + 30
90 + 40
95
(n 4)
2
95 + 40
(n = 4, 8, 12, 16)
(n 4)
2
(n = 4, 8, 12, 16)
60
65
(n 2)
10 + 30
2
(n 4)
55 + 30
2
(n 4)
60 + 30 2
(n 4)
65 + 30 2
(n = 2, 4, 6, 8)
(n = 4, 8, 12, 16)
(n = 4, 8, 12, 16)
(n = 4, 8, 12, 16)
(n = 4, 8, 12, 16)
15
80
85
95
100
10
15 + 40
(n 2)
2
55
(n 4)
2
80 + 40
85 + 40
(n 4)
2
95 + 40
70
70 + 30
(n 4)
2
100 + 40
(n = 2, 4, 6, 8)
(n = 4, 8, 12, 16)
(n = 4, 8, 12, 16)
(n = 4, 8, 12, 16)
10
60
65
70
10 + 30
(n 2)
2
(n = 2, 4, 6, 8)
(n 4)
2
60 + 30
(n = 4, 8, 12, 16)
65 + 30
(n 4)
2
70 + 30
(n 4)
2
(n 4)
2
(n = 4, 8, 12, 16)
75
(n 4)
2
75 + 30
(n 4)
2
(n = 4, 8, 12, 16)
(n = 4, 8, 12, 16)
(n = 4, 8, 12, 16)
120
100
110
(n 2)
15 + 55
2
(n 4)
90 + 55
2
(n 4)
100 + 55
2
(n 4)
110 + 55
2
120 + 55
(n = 2, 4, 6, 8)
(n = 4, 8, 12, 16)
(n = 4, 8, 12, 16)
(n = 4, 8, 12, 16)
(n = 4, 8, 12, 16)
100
110
120
15
20
20 + 55
(n 2)
2
(n = 2, 4, 6, 8)
15
25
25 + 55
(n 2)
2
(n = 2, 4, 6, 8)
15
75
15 + 50
(n 2)
2
90
90
90 + 55
(n 4)
2
100 + 55
(n 4)
2
(n 4)
2
110 + 55
120 + 55
(n = 4, 8, 12, 16)
100
(n = 4, 8, 12, 16)
110
(n = 4, 8, 12, 16)
120
110
120
130
140
110 + 55
(n 4)
2
(n = 4, 8, 12, 16)
90
90 + 50
(n 4)
2
120 + 55
(n 4)
2
(n = 4, 8, 12, 16)
100
100 + 50
130 + 55
(n 4)
2
140 + 55
(n = 4, 8, 12, 16)
110
(n 4)
2
110 + 50
(n 4)
2
(n = 4, 8, 12, 16)
(n = 4, 8, 12, 16)
(n = 4, 8, 12, 16)
90 + 50 (n 2)
(n = 2, 4, 6, 8)
90
100 + 50 (n 2)
(n = 2, 4, 6, 8)
100
110 + 50 (n 2)
(n = 2, 4, 6, 8)
110
100
110
(n 2)
2
90
90 + 50
(n 4)
2
100 + 50
(n 4)
2
110 + 50
(n 4)
2
(n = 2, 4, 6, 8)
(n = 4, 8, 12, 16)
(n = 4, 8, 12, 16)
(n = 4, 8, 12, 16)
75 + 50 (n 2)
(n = 2, 3, 4)
15
35
100
35 + 30 (n 2)
(n = 2, 3, 4)
90 + 50 (n 2)
(n = 2, 4, 6, 8)
90
75
100
75 + 30 (n 2)
(n = 2, 4, 6, 8)
100 + 50 (n 2)
(n = 2, 4, 6, 8)
100
80
100
80 + 30 (n 2)
(n = 2, 4, 6, 8)
110 + 50 (n 2)
(n = 2, 4, 6, 8)
110
90
100
90 + 30 (n 2)
(n = 2, 4, 6, 8)
100 + 100 (n 2)
(n = 2, 3, 4)
10
(n 4)
2
(n = 4, 8, 12, 16)
75 + 50 (n 2)
(n = 2, 3, 4)
10
20
20 + 50
(n 4)
2
(n = 4, 8, 12, 16)
90
(n = 2, 4, 6, 8)
75
(n 4)
2
100 + 100 (n 2)
(n = 2, 4, 6, 8)
75
80
90
21
Series CA2
D-A44
20
100
20 + 35 (n 2)
(n = 2, 3, 4)
Same surface
Different surfaces
Same surface
1
Different surfaces
Same surface
Different surfaces
D-A44C
D-Y69 /Y7PV
D-Y7 WV
D-Y7BA
D-P3DW
D-P4DW
80 + 30 (n 2)
(n = 2, 4, 6, 8)
90 + 30 (n 2)
(n = 2, 4, 6, 8)
75 + 50 (n 2)
(n = 2, 4, 6, 8)
75
75
100
75 + 35 (n 2)
(n = 2, 4, 6, 8)
80 + 50 (n 2)
(n = 2, 4, 6, 8)
80
80
100
80 + 35 (n 2)
(n = 2, 4, 6, 8)
90 + 50 (n 2)
(n = 2, 4, 6, 8)
90
90
100
90 + 35 (n 2)
(n = 2, 4, 6, 8)
80 + 35 (n 2)
(n = 2, 4, 6, 8)
90 + 35 (n 2)
(n = 2, 4, 6, 8)
55 + 50 (n 2)
(n = 2, 3, 4)
10
75 + 50 (n 2)
(n = 2, 4, 6, 8)
75
80 + 50 (n 2)
(n = 2, 4, 6, 8)
80
90 + 50 (n 2)
(n = 2, 4, 6, 8)
90
(n = 2, 4, 6, 8)
2 (Different surfaces
and same surface) 1
(n = 2, 4, 6, 8)
(n = 2, 4, 6, 8)
90
95
(n 4)
85 + 40 2
(n 4)
90 + 40 2
(n 4)
95 + 40 2
(n = 4, 8, 12, 16)
(n = 4, 8, 12, 16)
(n 4)
105 + 40 2
(n = 4, 8, 12, 16)
(n = 4, 8, 12, 16)
75
80
(n 4)
65 + 30 2
(n 4)
75 + 30 2
(n 4)
80 + 30 2
90
(n 4)
(n = 4, 8, 12, 16)
(n = 4, 8, 12, 16)
90 + 30 2
(n = 4, 8, 12, 16)
95
100
105
110
(n 4)
95 + 45 2
(n 4)
100 + 45 2
(n 4)
105 + 45 2
(n = 4, 8, 12, 16)
(n = 4, 8, 12, 16)
(n 4)
110 + 45 2
(n = 4, 8, 12, 16)
(n = 4, 8, 12, 16)
85
(n 2)
15 + 50
2
(n 4)
85 + 50 2
(n = 4, 8, 12, 16)
(n = 2, 4, 6, 8)
15
15 + 65
105
65
15
2 (Different surfaces
and same surface) 1
90
85
20
2 (Different surfaces
and same surface) 1
80
(n = 4, 8, 12, 16)
(n 2)
20 + 45
2
90
(n 4)
80 + 40 2
(n = 4, 8, 12, 16)
(n 2)
10 + 30
2
2 (Different surfaces
and same surface) 1
100 + 100 (n 2)
(n = 2, 4, 6, 8)
80
80
10
90
75 + 30 (n 2)
(n = 2, 4, 6, 8)
75
(n 2)
15 + 40
2
100
80
75
15
80
75 + 35 (n 2)
(n = 2, 4, 6, 8)
1
2 (Different surfaces
and same surface) 1
63
100 + 100 (n 2)
(n = 2, 3, 4, 5)
10
20
55
20 + 35 (n 2)
(n = 2, 3, 4)
Same surface
50
75
10
1
Different surfaces
D-A3 C
D-G39C
D-K39C
40
55 + 50 (n 2)
(n = 2, 3, 4)
Same surface
D-Z7 /Z80
D-Y59 /Y7P
D-Y7 W
Center trunnion
Number of
Brackets other than
auto switches
center trunnion
Different surfaces
35
55
Same surface
35 + 3 (n 2)
Different surfaces
(n = 2, 3, 4)
120
(n 2)
2
130
(n 4)
120 + 65 2
(n = 4, 8, 12, 16)
(n = 2, 4, 6, 8)
140
(n 4)
(n 4)
130 + 65 2
(n = 4, 8, 12, 16)
140 + 65 2
(n = 4, 8, 12, 16)
Operating Range
(mm)
Auto switch model
Bore size
40
50
63
80
100
D-A9 /A9 V
7.5
8.5
9.5
9.5
10.5
D-M9 /M9 V
D-M9 W/M9 WV
D-M9 A/M9 AV
4.5
5.5
D-Z7 /Z80
8.5
7.5
9.5
9.5
D-A3 /A44
D-A3 C/A44C
D-A5 /A6
10
11
11
6
10.5
11
D-B5 /B64
D-A59W
13
13
14
14
15
D-B59W
14
14
17
16
18
(mm)
Auto switch model
D-Y59 /Y69
D-Y7P/Y7 V
D-Y7 W/Y7 WV
D-Y7BA
D-F5 /J5 /F5 W
D-J59W/F5BA
D-F5NT/F59F
D-G5 /K59/G5 W
D-K59W/G5BA
D-G5NT/G59F
D-G5NBL
D-G39/K39
D-G39C/K39C
D-P3DW
D-P4DW
Bore size
40
50
63
80
100
5.5
6.5
6.5
4.5
4.5
4.5
6.5
6.5
35
35
40
40
40
10
10
11
4.5
4
5
4
6
4.5
5.5
4
6
4.5
Values which include hysteresis are for guideline purposes only, they are not a guarantee (assuming approximately 30% dispersion) and may change substantially depending on the ambient environment.
22
Series CA2
D-A9
D-M9
D-M9
D-M9
40
/A9 V
/M9 V
BA7-040
W/M9 WV
A/M9 AV
D-A5 /A6
D-A59W
D-F5 /J5
D-F5 W/J59W
D-F59F/F5NT
D-A3 C/A44C
D-G39C/K39C
D-Z7 /Z80
D-Y59 /Y69
D-Y7P/Y7PV
D-Y7 W/Y7 WV
D-Y7BA
D-P3DW
D-P4DW
<Band mounting>
Bore size (mm)
50
63
80
Auto switch
model
100
BA7-040
BA7-063
BA7-080
BA7-080
BT-04
BT-04
BT-06
BT-08
BT-08
BA3-040
BA3-050
BA3-063
BA3-080
BA3-100
BA4-040
BA4-040
BA4-063
BA4-080
BA4-080
D-A3 /A44
D-G39/K39
40
50
BDS-04M BDS-05M
D-B5 /B64
D-B59W
D-G5 /K59
D-G5 W/K59W BH2-040
D-G59F
D-G5NT
D-G5NB
BA5-050
63
80
100
BMB1-063
BMB1-080
BMB1-100
BAF-06
BAF-08
BAF-10
The following stainless steel mounting screw kit (including set screws) is also
available. Use it in accordance with the operating environment.
(Since the auto switch mounting bracket is not included, order it separately.)
BBA1: For D-A5/A6/F5/J5 types
BBA3: For D-B5/B6/G5/K5 types
Note 2) Refer to pages 1357 and 1365 in Best Pneumatics No. 2 for details on
the BBA1 and BBA3.
The above stainless steel screws are used when a cylinder is shipped with
D-F5BA or G5BA auto switches. When only an auto switch is shipped
independently, the BBA1 or BBA3 is attached.
Note 3) When using the D-M9 A(V) or Y7BA, do not use the steel set screws
which are included with the auto switch mounting brackets above (BA7,
BA4). Order a stainless steel screw kit (BBA1) separately, and use
the M4 x 6L stainless steel set screws included in the BBA1.
Note 4) There is a difference in the cylinder tube thickness depending on the
cylinder model. When a band mounting type is used as an applicable
auto switch and a cylinder model is changed, use caution.
The figure shows the mounting example for the D-A9 (V)/M9 (V)/M9 W(V)/M9 A(V)L types.
Other than the applicable auto switches listed in How to Order, the following auto switches can are mountable.
Refer to Best Pneumatics No.2 for detailed specifications.
Type
Model
D-A93V/A96V
Reed
D-A90V
D-A53/A56/B53/Z73/Z76
D-A67/Z80
Electrical entry
Grommet (Perpendicular)
Grommet (In-line)
D-M9NV/M9PV/M9BV
Grommet (Perpendicular)
D-Y7NWV/Y7PWV/Y7BWV
D-M9NAV/M9PAV/M9BAV
Solid state
D-Y7NW/Y7PW/Y7BW
D-F5NT/G5NT
D-P5DW
D-F59/F5P/J59
D-F5BA/Y7BA
D-Y59A/Y59B/Y7P
D-F59W/F5PW/J59W
D-Y69A/Y69B/Y7PV
D-M9NWV/M9PWV/M9BWV
Features
Grommet (In-line)
With pre-wired connector is also available for solid state auto switches. For details, refer to pages 1328 and 1329 in Best Pneumatics No. 2.
Normally closed (NC = b contact) solid state auto switches (D-F9G/F9H/Y7G/Y7H) are also available. For details, refer to pages 1290
and 1292 in Best Pneumatics No. 2.
Wide range detection type, solid state auto switch (D-G5NBL) is also available. For details, refer to page 1320 in Best Pneumatics No. 2.
23
Prior to Use
3-wire, NPN
3-wire, PNP
Brown Input
Auto switch
Black
Auto switch
Blue
Black
Blue
COM
2-wire
Brown Input
COM
2-wire
Brown Input
Brown COM
Auto switch
Auto switch
Blue
Blue
COM
Input
Connect according to the applicable PLC input specifications, as the connection method will vary depending on the PLC input specifications.
3-wire,
OR connection for NPN output
(Using relays)
Auto switch 1
Auto switch 2
Relay
Black
Brown
Load
Auto switch 1
Brown
Black Relay
Auto switch 1
Blue
Blue
Blue
Brown
Brown
Brown
Black
Auto switch 2
Black
Auto switch 2
Blue
Blue
Brown
Auto switch 2
Relay
Auto switch 1
Brown
Black
Auto switch 1
Black
Blue
Blue
Blue
Brown
Brown
Brown
Black
BlackRelay
Auto switch 2
Load
Blue
2-wire,
AND connection
Load
Auto switch 1
Blue
Brown
Auto switch 2
Auto switch 2
Blue
Black
Relay
Blue
2-wire,
AND connection
Brown
Blue
Brown
Load
Auto switch 1
Blue
Brown
(Solid state)
(Reed)
Because there is no leakage current, the load voltage will not increase in
the OFF state. However,
depending on the number of auto switches in
the ON state, the indicator lights may sometimes
grow dim or not light up,
due to the dispersion and
reduction of the current
flowing to the auto
switches.
Auto switch 2
Blue
24
Black
3-wire,
OR connection for PNP output
(Using relays)
Black
Relay
Blue
3-wire,
AND connection for PNP output
Auto switch 1
Black
Simple Specials
These changes are dealt with Simple Specials System. Refer to Best Pneumatics No. 2 for details.
Symbol
-XA0 to -XA30
Description
CA2
Air cylinder
Model
CA2
CA2W
Action
Double acting, Single rod
Double acting, Double rod
Note
Precautions
1. SMC will make appropriate arrangements if no dimension, tolerance, or finish
instructions are given in the diagram.
2. Standard dimensions marked with will be as follows to the rod diameter (D).
Enter any special dimension you desire.
Symbol: A0
Symbol: A1
D 1 mm, 6 < D
30
RD
MM
Symbol: A9
C
30
H
30
H
Symbol: A11
Symbol: A10
R sphere
TP
R sphere
DC
AL MM
AL
30
H
30
H
Symbol: A8
Symbol: A7
AL
MM
Symbol: A3
W1
H
Symbol: A6
Symbol: A5
RD
D 4 mm
30
Symbol: A4
C0.5
DA
30
D 2 mm, D > 25
25
3 .In the case of double rod type and single acting retraction type, enter the
DA
30
AL
MM
A
30
DA
MM
DB
30
T
H
Symbol: A25
Symbol: A24
MM
Symbol: A22
MM
Symbol: A29
30
RD
30
A
H
DA
30
LBK
MM
Symbol: A30
Symbol: A23
Symbol: A27
30
MM
A
H
30
30
30
A
AL
AL L K
H
AL
MM
30
MM
Symbol: A26
MM
DA
30
MM
Symbol: A21
A LK
H
Symbol: A19
H
30
MM
A
H
Symbol: A18
MM
DA
30
Symbol: A17
Symbol: A15
30
Symbol: A20
Symbol: A28
DA
AL
MM
MM
Symbol: A14
W1
H
Symbol: A16
DA
30
DA
Symbol: A13
DA
R sphere
C0.5 DA
DB
Symbol: A12
W1
H
MM
L
H
AL
A
T
A
H
25
Series CA2
Simple Specials
These changes are dealt with Simple Specials System.
Symbol
-XC14
The position for mounting the trunnion bracket on the cylinder can be moved from the standard mounting position to any desired position.
Applicable Series
Series
Description
CA2
Air cylinder
Model
CA2
CA2W
Action
Double acting, Single rod
Double acting, Double rod
Note
Z + 1/2 Stroke =
Precautions
1. Specify Z + 1/2 Stroke in the case the trunnion bracket position is not
-XC14A, B or trunnion is not a center trunnion.
2. SMC will make appropriate arrangements if no dimension, tolerance, or
finish instructions are given in the diagram.
3. The possible range of trunnion bracket mounting position is indicated in
the table below.
4. Some trunnion mounting positions do not allow auto switch mounting.
Please consult with SMC for more information.
(mm)
Z + 1/2 Stroke
For -XC14
Symbol
Bore size
40
50
63
80
100
For -XC14A
For -XC14B
89
99
103
125
132
97 + Stroke
107 + Stroke
111 + Stroke
133 + Stroke
138 + Stroke
Minimum
89.5
99.5
103.5
125.5
132.5
Maximum
96.5 + Stroke
106.5 + Stroke
110.5 + Stroke
132.5 + Stroke
137.5 + Stroke
Reference
Standard (Center trunnion)
93 + 1/2 Stroke
103 + 1/2 Stroke
107 + 1/2 Stroke
129 + 1/2 Stroke
135 + 1/2 Stroke
Minimum stroke
1
1
1
1
1
Symbol
-XC15
Applicable Series
Series
Description
CA2
Air cylinder
Model
CA2
CA2W
Action
Double acting, Single rod
Double acting, Double rod
Note
Precautions
M=
M=
M Min.
M Max.
26
(mm)
Series CA2
Made to Order 1
Made to
Order
Please contact SMC for detailed dimensions, specifications and lead times.
Symbol
-XC7
When using in locations where the rust generation or corrosion likelihood exists, the standard parts material have been partly changed to the stainless steel.
Applicable Series
Series
Description
CA2
Air cylinder
Model
CA2
CA2W
How to Order
Action
Double acting, Single rod
Double acting, Double rod
Note
Specifications
Component parts changed
to stainless steel
Additional specifications
Dimensions
XC7
Symbol
-XC8
It adjusts the extending stroke by the stroke adjustable mechanism equipped in the head side.
(After the stroke is adjusted, with cushion on both sides is altered to single-sided, with cushion.)
Applicable Series
Series
Description
Air cylinder
CA2
Model
CA2
Action
Double acting, Single rod
Note
How to Order
CA2
Mounting
Bore size
Stroke
Suffix
XC8
Specifications
Stroke adjustment symbol Stroke adjustment range (mm)
A
0 to 25
CA2- Z
B
0 to 50
Precautions
Series
Warning
Dimensions (Dimensions other than below are the same as the standard type.)
Width
across flats MG
MI
MN
MK
4
H2
Width
across flats B2
ML + Adjustment
Stroke
MH + Stroke + Adjustment
ZZ + 2 x Stroke + Adjustment
Dimensions
Symbol
Stroke range
Bore size
Up to 500
40
Up to 600
50
Up to 600
63
Up to 750
80
Up to 750
100
(mm)
B
H2
MN
ZZ
MG
MH
MI
MK
ML
60
70
85
102
116
6
8
8
10
12
M10 x 1.25
M14 x 1.5
M14 x 1.5
M16 x 1.5
M20 x 1.5
180
197
205
253
267
19
24
24
27
32
45
49
49
66
69
32
38
38
45
55
10
13
13
14
17
22
24
24
32
35
27
CA2
Series
Made to Order 2
Made to
Order
Please contact SMC for detailed dimensions, specifications and lead times.
Symbol
3 Rod Trunnion
-XC30
This cylinder shortens the distance between the fulcrum and the rod end by installing a trunnion bracket in front of the rod cover.
Applicable Series
Series
Description
Air cylinder
CA2
Model
CA2
Action
Double acting, Single rod
Note
How to Order
CA2 T
XC30
Rod trunnion
TY
GA
TT
TDe8
TX
S + Stroke
TZ
ZZ + Stroke
Dimensions
Symbol
Bore size
40
50
63
80
100
28
(mm)
Stroke range
GA
TDe8
TT
TX
TY
TZ
ZZ
Up to 1000
Up to 1000
Up to 1000
Up to 1000
Up to 1000
23
26
27
32
35
11
13
13
16
16
66
71
79
94.5
100
80
86
94
111
121
15 -0.032
-0.059
15 -0.032
-0.059
18 -0.032
-0.059
25 -0.040
-0.073
25 -0.040
-0.073
22
22
28
34
40
85
95
110
140
162
62
74
90
110
130
117
127
148
192
214
55
60
65
77.5
80
151
163
179
212.5
229
Series CA2
Be sure to read before handling. Refer to back cover for Safety Instructions,
Handling Precautions for SMC Products (M-E03-3) and the Operation Manual for
Actuator Precautions and Auto Switch Precautions. Please download it via our website,
http://www.smcworld.com
Operating Precautions
Disassembly/Replacement
Caution
Caution
Caution
1. Use a socket wrench when the bracket is replaced.
If other tools are used, the nut or other parts may be
deformed or the work efficiency may decrease.
For applicable sockets, refer to the table below.
40, 50
63
80, 100
DA00040
JIS B1181 Class 3 Intermediate
M8 1.25
DA00010
JIS B1181 Class 3 Intermediate
M10 1.25
DA00131
JIS B1181 Class 3 Intermediate
M12 1.75
Disassembly/Replacement
Nut
Caution
Bore size
(mm)
Width across
flats
Socket
Tightening torque
(Nm)
13
JIS B4636
+ Two-angle socket 13
7.4
17
JIS B4636
+ Two-angle socket 17
20
19
JIS B4636
+Two-angle socket 19
29
D-A3 /A44
D-G39/K39
D-B5 /B64
D-B59W
D-G5 /K59
D-G5 W/K59W
D-G59F
D-G5NTL
40
50
63
80
100
BAF-08
BAF-10
29
Safety Instructions
Caution:
Warning:
Danger :
Caution
Warning
1. The compatibility of the product is the responsibility of the
person who designs the equipment or decides its specifications.
Since the product specified here is used under various operating conditions, its
compatibility with specific equipment must be decided by the person who designs
the equipment or decides its specifications based on necessary analysis and test
results. The expected performance and safety assurance of the equipment will be
the responsibility of the person who has determined its compatibility with the
product. This person should also continuously review all specifications of the
product referring to its latest catalog information, with a view to giving due
consideration to any possibility of equipment failure when configuring the
equipment.
Compliance Requirements
1. The use of SMC products with production equipment for the manufacture of
weapons of mass destruction (WMD) or any other weapon is strictly prohibited.
2. The exports of SMC products or technology from one country to another are
governed by the relevant security laws and regulations of the countries involved
in the transaction. Prior to the shipment of a SMC product to another country,
assure that all local rules governing that export are known and followed.
Safety Instructions Be sure to read Handling Precautions for SMC Products (M-E03-3) before using.
D-DN