Вы находитесь на странице: 1из 40
BURP eg or Sree EL} Component Replacement: Per Networking Hardware AR all Peer Card reader Port] ae . ee et DTU UD CLs overview Overview ‘This chapter contains replacement procedures for networking hardware. The player tracking boards (including Hubble, Acres, and network boards) are located under the top cap. The procedures for replacing each board shows board locations. Figure 12-1 shows the locations of the player tracking card reader, keypad, and display. The casino furnishes these three components. Figure 121 Curreney Column The following table lists the procedures in this chapter. Replacing the Hubble Board page 123 “Replacing ine Acres and DON Boards page 12-8 “Replacing the Network ineriace Board_page 12-12 ‘Replacing the Gard Reader age 12-30 FRepiacing the Keypaa page 12.34 Replacing te Display age 12.36 Fopiacing the Eternal Soard page 12.8 ‘Dayaney Operation and Serve Guide Publication Number: 820-0002-02, Rev. 8 23 Replacing the Hubble Board The player tracking system in the Odyssey slot machine requires a translator board and at least one network interface board under the top cap. The translator board is either an Acres board (with a DCN board) or a Hubble board. This section contains replacement procedures for the Hubble board. For replacement procedures for the Acres and DCN boards in an Acres configuration, see “Replacing the Acres and DCN Boards” on page 12-9. The kind of network interface board in a Hubble player tracking configuration, depends on the player tracking system, as shown in the following table: Player Tracking System Network Interface Boars cos" ‘Sentinel ang SMI MasterGom and DUKA IGT PTBSA ‘SMV. GH Universal ineraoa Soare ‘Caesars. TSTTaBA ‘Mikoha Mikohn SMB “eres Rio ‘Actes DON, Figure 12-2 on page 12-4 shows the top of the machine with CDS network interface >oards installed 4 Note: The plate that holds the SMEIV and Sentinel II boards may be rotated 160° @ so that the SMIIV board is installed to the right of the Sentinel board, as you face the machine. This difference in the locations ofthe two boards has no effect on the ‘operation of the slot machine. ‘rapier 1: Component Replace: Netwaring Harduar ‘Dayssey Operation and Service Guide a4 Repl Figue12-2 Location of Hubble and CDS Boards Prayer plate for CDS Boards “racking Mounting] |p SHIIV Boa Pie - Sentinel i Boars | >) Hole an | mn ooo uso | m-—7 Speake: Excsure ‘op Vew Set Weoine Figure 12-3. Location of Hubble and Bally Boards Figure 12:3 shows the top of the machine with a Bally interface board installed. Sor were PayesTosre By Maswcan 220 savanna femugbes | [Sewer tone | -——+, | | coco eo A ‘eaeor ba a [ =e ee 28 ‘The location for the following network boards is the same: IcT cst MGM Caesar's Mikoha (Only one of these boards is installed in a machine. Figure 12-4 shows the top of the machine with any one of these boards installed. Figwe12-4 Locations of Hubble and IGT, GSI, MGM, Caesars, and Mikohn Network Boards Payer Fates eon Bears Mounting Pie et [ 9 ooo = = unoie a ly “ereatr tere K spe: root De Parra Figure 12-5 on page 12-6 shows the top of the machine with an Acres DCN board installed in a Hubble configuration for Acres Rio. ‘rapier 12: Component Replacement: Newarang Hardware 125 __Replating the Figure 12-5 Location of Aeres DCN board in a Hubble Configuration Paes = sen Dood . I | Hole | Soa | = . _ Ld) | Hubble a TTC Tansiator Board | or | | _ | eroasue Top View of Set Washi ‘The following table is a summary of the sections in this procedure. If you are familiar with the procedure, you may prefer to read the text in the indicated sections only when necessary. Removing the Hubble Board Before beginning the procedure, be sure to tum the power off. To turn the power off, perform the following steps: 4. Open the currency column door. Refer to “Opening the Currency Column Door” on page 2: 2. Flip the power switch to the Off position. © Wem allure to tur off the machine can result in personal injury o= damage to equipment. ‘Dayasey Operation and Service Guide Publeaion Number 620-0002-02, Re. 8 the Hubble ‘To remove the Hubble board, perform the following steps: 4, Remove the top cap. Refer to “Removing the Top Cap” on page 2-16. 2 Unplug the connectors from the Hubble board. The locations for the connectors are marked on the board and are shown in Figure 12-6. The connectors to unplug, are different, depending on the network interface board, Table 12-1 on page 12-8 describes the connectors to unplug for each network interface board. Fine 26 Hubble Board Connectors ‘ara Reader Out Cars deel Lames Garo Reaser In” opr Sensors ‘2C Output Bround wo Crass a == 9955 Pep rou : =] 8 wt soe rai . . be x0 foe) & oO & BS Wm Fd cee gee ero Conecor Regis Coin Puse ogi Seria Date r | ers FY — pth eoetts a te L_ satyvasircon 9 Dspay Module 628 Serial Diy Brass IGT PTSSNSI “0. Keypad tian aie Uk ‘rapier 12 Comparert Replacement: Nebworling Haraware ‘bdyssey Operation and Se vie Guise 18. a 4 lug the 4 AC power connector fist Table 12-1 Hubble Connectors tor Network Interface Boards and Power pee oy Se eS od a ohn AC power, Son isemis x Xk kX “B Setalinerace pn, 186mis xx x x x x emeen the GFIO Doata ane the Hubble board TS__0ds SMiVbead Spin, 100 mie x ran BDC power ‘pin, 156 mis x x x Tid Baly MasierCom ——7-pin, 100 mis x seria interface Tie Seralirierace __ pin, 100 mils x" ® x Demween tne Pras and the Hubb boars Tid Dispiay nterace pi, 100 mis x x TS 1GT dsniay “pin, 100 mils x Tt LeDaiver SoneiGT &-pen, 100 mils x ‘boares may not have this connector) Boor intertace pin, 100 mis x =e Remove the screws securing the board to the top of the cabinet. Lift the board from the top of the cabinet. Installing the Hubble Board To install the Hubble board, perform the following steps. os e ‘ayasey Operation and Service Guide Refer to Figure 12-2 on page 12+ (ifthe machine has a CDS board) or Figure 12-3 on page 12+ (ifthe machine has Bally boards). Place the Hubble board over the six pem nut standoffs in the top of the cabinet, The standofs are labeled 1 through 6 in the figures. Note: If you are replacing an Acres board with a Hubble board, the sx % standotis are the same standofis used to secure the Acres DCN plate to the top of te cabinet Align the six screw holes in the board with the six pem nut standoffs. Secure the board to the machine with six screws. you are replacing an Acres translator board with a Hubble translator board, and the machine is configured for the Bally player tracking system, instal the Bally DMKA board as follows: ‘® Align the holes of the Bally DMKA board (removed from the Acres DCN plate) with the holes shown for the Bally DMKA board in Figure 12-3 on page 124. Secure the board to the mounting plate, using the standoffs in each comer of the plate. nication Nombar 620-0002-02, Rev 8 & Configure the MMS. For the procedure, see “Configuring the Network” on page £20. Verifying Hubble Board Operation To verify Hubble board operation, perform the following steps: 1. To verify that the Hubble board is communicating with the slot machine and the Copsey eran sae D168 Tails 008 bare 9,010 Tie Seabee Boe Tile oT hee oreo Tai GSTbead orb Tab WaT Soe oa bt Table Case baad BY, ani a om Foti Aves DONT) BT, ‘2 Install the top cap. Refer to “Installing the Top Cap” on page 2-16. Replacing the Acres and DCN Boards The player tracking system in the Odyssey slot machine requires @ translator board and at least one network interface board under the top cap. The translator board is either an Acres board (with 2 DCN board) or a Hubble board. ‘This section contains replacement procedures for the Acres and DCN boards. For replacement procedures for the Hubble board, see “Replacing the Hubble Board” on page 12.3. For the replacement procedure for the Acres DCN board in a Hubble configuration, see the procedure “Removing the Acres Rio Board from a Hubble Configuration” on page 12-21. Important: In an Actes configuration, whenever an Acres translator board or an Acres DCN board needs replacement, you must replace both boards with a single ‘Hubble translator board. (The Acres boacds are being phased out for Acres configurations.) You need not replace the network interface board, but you may hhave to change its location. ‘Ina Hubble configuration such as Acres Rio, whenever the Acres DCN board needs replacement, you replace only the Acres DCN board. ‘haater 1: Component Replacement Networting Haroware ‘Deyesey Operation and Service Guide ‘The kind of network interface board in an Acres player tracking configuration depends on the player tracking system, as shown in the following table: coe ne Bays iy ‘The following table is a summary of the sections in this procedure. If you are familiar with the procedure, you may prefer to read the text in the indicated sections only when necessary. Seana hate tomas Sparng br baa Favor Saas ETT “Honavrg e Ras Tans an Atos DON BO on page ETE pouring he Hale Board"on page Important Do rt sal Acres bars "eriping Hobbie Board Operon” on pape TE Removing the Acres Boards Before beginning the procedure, be sure to turn the power off. To tum the power off, perform the following steps: 1. Open the currency column door. Refer to “Opening the Currency Column Door” on page 2-8 2 Flip the power switch to the Off position. 4 teres Failure totum off the machine can result in personal injury or damage to equipment. Preparing for Board Removal To access the Acres boards, you must remove the top cap. Refer to “Removing the Top Cap” on page 2-16. Figure 12-7 on page 12-11 showss the top of the machine with CDS network interface boards installed. ‘ayssey Operation and Service Guide uBlcavon Number 820-0002-02, Rev. 8 Dew Boarts 249 Fipwe2? Location ot Aees and CDS Boards erp Poros Bears reas 5 pdr Yar reser 7 | F suv ae howe i serine r P | | Hole oon —— fe al | | fers 204 oon a 8 2 LL ses 00 TY mae aes Top View of Sit Machine Co) Figure 12:8 shows the top of the machine with a Bally network interface board installed. Fipue28 Location of Acres and Bally Boards PryesTacks Bly Maxercon 220. dees Tamlar Mowing a | [ heer sous Beard | a6 | occ | | Le ale Jd) || dit reer oon | soar | L 2 Acres DCN a] Pas -—s aly DKA Network see Speaior “op View of Si Marnine| — Enclosure [ ‘rapier 2: Component Replacement: Networking Hardware 1242 Replacing the Network Interface Removing the Acres Translator and Acres DCN Boards To remove the Acres boards, perform the following steps: 4. Unplug the connectors from the Acres board. The connectors to unplug are different, depending on the network interface board. ‘Table 12-2 describes the connectors to unplug for the CDS and Acres network interface boards. ( "portant: Unplug the power cable from the J3 connector on the Actes translator board first. Tike 12.2 Acres Board Connections CoyneySveseerel sey loeetrecartertcmeres GIO POT PRE Taree ON comet’ Soke Ft Fares Vana toad onnOGaT ‘ses Tana bead concer HT aro 8 CDS) or WaT 2 connector J2 Bally) 2 Ifthe machine is configured for a Bally board, refer to Figure 12-8 on page 12-11 and remove the Bally DMKA board. Set the board aside for later installation. 3% Remove the Acres DCN plate by lifting up the plate at each of the standotf locations until the plate is free from the machine. Installing the Acres Boards Do not replace Acres translator and DCN boards with new Acres boards. Instead, replace them with one Hubble board. See “Installing the Hubble Board” on page 12-6. Replacing the Network Interface Board ‘This section contains procedures for replacing the following network interface boards: * cps Bally IcT cst MGM Cacsar’s Mikohn + Acres Rio The following table is « summary of the sections in this procedure. Perform the procedure “Preparing for Board Removal” on page 12-13, followed by the appropriate removal and installation procedure. Then perform “Verifying Network Interface ‘eyesey Operation and Service Gude Publication Number 620-0002-02, Fev 8 Replacing the Network ntertace Board 12-13 Board Operation” on page 12-30. If you are familiar with the procedure, you may prefer to read the text in the indicated sections only when necessary. "Preparing for Board Remove? on page 1212 “Removing te GOS Board from an Acres Gonfiguraton” on page 127 "Removing te GOS Board from a HubHe Configuration” on page 127 “Removing me Baly Boards rom an Acres Configurabor” on page 12-16 “Removing ne Baly Soaras tom a Hubble Configurator” on page 12-17 “Rerroving ne IGT Soard From a Huboie Configuration” on page 7 ‘Removing he GSI Board fom a nupble Gonfiguraion” on page 12-76 ‘Removing te MGM Board From a Hubble Gantiguraton” on pa Removing he Caesars 6O8r6 fom a Hubble Configuration” on page 7 “Tflemoving ihe Mikonn Boars from a Hubble Configuration” on page 12:20 ‘TRlemonng ie Acres Fo Board rom @ Hubble Configurator” on page 1227 aling the Network Interface Board” on page 12-27, Tinstaling the COS Boards in an Acres Configuration” on page Tinstaling the IGT Board in a Hubble Configuration” on page 12-26 Tinsialing he GSI Beard in a Hubsle Coniguraion" on page 12-27 Tinstaling te MGM Soard ina Hubble Contig instaling he Gaesars Board in a Hubble Configural “instaling the Mikohn Boardin a Hubole Configuration” on page 12-28 insialing the Acres Rio Board in @ Hubble Configuration” on pag rifying Network Interface Board Operation” on pat Removing the Network Interface Board To remove a network interface board, you must perform some preliminary steps. Preparing for Board Removal Before beginning the procedure, be sure to turn the power off ‘To tum the power off, perform the following steps: 4. Open the currency column door. Refer to “Opening the Currency Column Door” on page 2-8. 2. Flip the power switch to the Oif position. > Mersie Follure to tum off the machine can result in personal injury or damage to equipment. To prepare for board removal, perform the following steps: 1. Remove the top cap. Refer to “Removing the Top Cap” on page 2-16. 2 Depending on which network interface board you are replacing, find and perform the appropriate removal procedure below. Chapter 1: Component Replacement Neworkng Haraware ‘Oayssey Operation and Service Guide 218 ep 19 the Network nterta Removing the CDS Board from an Acres Configuration ‘To remove the CDS network interface boards from an Acres configuration, refer to Figure 12-7 on page 12-11 and perform the following steps: @ Important: The CDS network interface boards consist of an SMI IV board mounted oma plate with a Sentinel I board. You must replace both boards by removing the ‘mounting plate with the boards. 4. Refer to Table 12:3 and unplug the following network power connections: © Waring: Be sure to disconnect the Odyssey 9Vde power supply fom the Acres translator board first Titie12.3_CDS/Aeres Network Power Connections = a uyssey 8Vee power suppy (under Actes wansiator Boars connector JS feat mounting plate of Aares boards) ‘Oayssey Vas power supp SMIIV connector 2 Refer to Teble 12-4 and disconnect the following slot lines: Tible124 CDS Slot Line Connections fo Z [GDS Sentinal connector Je Bankin sot ine (GDS Sentinal connector 5 Bank out siting '& Disconnect the door sensors cable for the drop-door switch as follows Determine whether pin 9, in the long white connector near the left edge of the SMIIV board, is connected to a green and white cable (for a magnetic drop- oor switch) or a black and red cable (for a mechanical drop-deor switch). Important: Pin 9is configured for the drop-door switch at the factory, but the casino may have reconfigured the long white connector so that the drop-door switch connector must be plugged into a different pin. Disconnect the cable from pin 9, or the reconfigured pin, and make a note of the pin number and the colors of the cable you disconnected. 4 Refer to Table 12-5 and unplug the following data signal connections: Tuble125 _DSIAeres Data Signal Connections From a OGN connector Ps ‘Acres translator board connector Pi ‘Acres vansiator board connector It SMI connecter JB iayasey Operation and Service Guide Pablcation Number: €20-0002-0, Fv 8 acing r8 5. Refer to Table 12-6 and unplug the following discrete signal connections: ‘Tuble126 CDS Discrete Signal Connections Sone eee res connec dg” groups? and Taam Sarit career cas iepad Serine camer IE ‘Sentinel i connector GOS aispiay 6 Refer to Figure 12-7 on page 12-11 and remove the CDS boards by pulling up on the player-tracking mounting plate at each standoff location until the plate snaps off the top of the machine. Lift the plate and CDS boards from the machine. ‘To install the new CDS boards, proceed to “Installing the CDS Boards in an Acres, Configuration” on page 12-22. Removing the CDS Board from a Hubble Configuration ‘To remove the CDS network interface boards from a Hubble configuration, refer to Figure 12-2 on page 12-4 and perform the following steps: Important: The CDS network interface boards consist of an SMIIV board mounted ona plate with a Sentinel I!board. You must replace both boards by removing the ‘mounting plate with the boards. ad) No, Injurisictons with loss limit regulations that prevent players from losing ‘more than $500 per day, a loss lockout board is installed. The board is provided by the casino and is located on the player-tracking mounting plate. For removal instructions, see the casino operator. 4. Refer to Table 12-7 and unplug the following network power connections: © Wering_Be sure to unplug the power supply from the Hubble translator board frst. ‘Tiile127 HUBBIG/CDS Network Powar Connections = Z ayssey unsuicned power supply Hubble connector v Hoppe connecter JS 'SMIIV connector J5 OF ‘Sentinel Vee 2 Refer to Table 12-8 and disconnect the following slot lines: Titie12-8 CDS Slot Line Connections oa m Senne I connector J Bankin sit line ‘Senne connector 15 Bank out sicting ‘Grapes 12: Component Replacement Nenworing Haraware ‘oaysey 34 the Network ntrtaze doart ‘3 Disconnect the door sensors cable for the drop-door switch as follows: Determine whether pin 9, in the long white connector near the left edge of the SMIIV board, is connected to a green and white cable (for 2 magnetic drop- door switch) or a black and red cable (for a mechanical drop-door switch) important: Pin 9 is configured for the drop-door switch atthe factory, but the casino may have reconfigured the long white connector so that the érop-door switch connector must be plugged into a ditferent pin. b Disconnect the cable from pin 9, or the reconfigured pin, and make a note of the pin number and the colors of the cable you disconnected. 4 Unplug Hubble connector J15 from the SMITV connector J8. 5 Refer to Table 12-9 and unplug the following discrete signal connections: ‘Tile 129 CDS Discrete Signal Connections. = Ooyssey uBble connector J2 and SMI IV ‘connector J7, pin groups 7 and 8 (GDS card reader ‘Sentinal i eannector J (CDS keypad ‘Sentinel i connector 16 ‘Sentinal I comestor Jt (COS display Refer to Figure 12-2 on page 12-4 and remove the CDS boards by pulling up on the player-tracking mounting plate at each standoff location until the plate snaps off the top of the machine, Lift the plate and CDS boards from the machine. To install the new CDS boards, proceed to “Installing the CDS Boards in a Hubble Configuration” on page 12-23, Removing the Bally Boards from an Acres Configuration ‘To remove the Bally network interface boards from an Acres configuration, refer to Figure 12-8 on page 12-11 and perform the following steps: 4. Refer to Table 12-10 and unplug the following network power connections: 4 Werte: Be sure to unplug the power supply from the Acres translator board first ‘Table 12-10 Bally/Acres Network Power Connections Ouyssey Sac power supply (under Acres vanslator boara connecter rear mounting plate of Acres boarcs) Oayssey Vee powor supply MasterGor 250 connestor 1 2 Unplug the connection from the Bally MasterCom 220 connector J3 to the slot line. Refer to Table 12-11 and unplug the following data signal connections: e Table12-11 _Bally/Acres Data Signal Connections DCN connector Pt ‘Acres translaor boars connecter Py “Acres translator board connector J2 _ MastorGom 220 eannecior J2 ‘Déyesey Operation and Service Gude Publication Nomber 620-0000-02, Rav. 8 Replacing the Network Inetace Board 12417 4 Refer to Table 12-12 and unplug the following discrete signal connections: ‘able1212 Bally Discrete Signal Connections = = {GIO port PST MastarCom 220 connector 15, Bally cara eager DUKA board connector 3 Bally Keypad and dapiay DMA board connector 6 5 Refer to Figure 12-8 on page 12-11 and remove each Bally board by lifting up the board at each of the standoff locations until the board is free of the player-tracking ‘mounting plate. To install the new Bally boards, proceed to “Installing the Bally Boards in an Acres, Configuration” on page 12-24. Removing the Bally Boards from a Hubble Configurati To remove the Bally network interface boards from a Hubble configuration, refer to Figure 123 on page 12-4 and perform the following steps: 4, Refer to Table 12-13 and unplug the following network power connections: © Wem Besure to unplug the power supply from the Hubble translator board first. Tihs 12-23_BallyMubble Network Power Connestions uyssey unswitched power supply Hubs connector J Hubble connector 3 ‘MastorGom 220 connecter JT 2 Unplug the connection from the MasterCom 220 connector J8 to the slot line. 8 Refer to Table 12-14 and unplug the following data signal connections: Title 1214 Bally€Mubble Data Signal Connections uable comector 18 ‘MasierCom 220 connector 2 {GIO pon P36 ube connector Je 4 Refer to Table 12-15 and unplug the following discrete signal connections: ‘Thble1225 Bally Diserete Signal Connections {GPIO pon PS? MasierCom 220 connector J13, Bally eara reader DMKA board connector 3 Bally Keypaa ana aspiay DMKA board connector 8 Refer to Figure 12-3 on page 12-4 and remove each Bally board by lifting up the board at each of the standoff locations until the board is free of the player-tracking ‘mounting plate. To install the new Bally board Configuration” on page 12- “Installing the Bally Boards in a Hubble Networking Faraware ‘Dayasey Operation and Service Guise 1248 Removing the IGT Board from a Hubble Configuration ‘To remove the IGT network interface board from a Hubble configuration, refer to Figure 12-4 on page 12-5 and perform the following steps: 4. Refer to Table 12-16 and unplug the following network power connections: 4 Wersng: Be sure to unplug the power supply from the Hubble translator board first. ‘TBbie 1215 IGT Network Power Connections = To uyssey unswiicned power supply Hubble connector v4 "Hunbie connector PTOSA connector 13 2 Unplug the connection from the PT95A connector Ji to the slot line. Unplug the connection from the Hubble connector J16 to the PT95A connector 5. 4. Refer to Teble 12-17 and unplug the following discrete signal connections: » Tibie1217 IGT Diserete Signal Connections f= To, (GPIO por PST [PTSA board connacior JS IGT cara rescer 'PTSEA board connector 2 Hubble connector 14 Tet Raypad ana dapiay File connector 78 8 Remove the IGT PT95A board by lifting itup at each of the standoff locations until the board is free of the player-tracking mounting plate. ‘To install the new IGT board, proceed to “Installing the IGT Board in a Hubble Configuration” on page 12-26 to. ‘Removing the GSI Board from a Hubble Configuration To remove the GSI slot machine interface board (SMIB) from a Hubble configuration, refer to Figure 12-4 on page 12-5 and perform the following steps: 44 Refer to Table 12-18 and unplug the following network power connections: 4 Werner Be sure to unplug the power supply from the Hubble translator board first. Tibie 1218 GSI Network Power Connections From a ‘Ocyssey unswitched power supaly Hubble connector J (Oayssey unswitchad power sunply __SMIB connector J8 2 Unplug the connection from the SMIB connector J7 to the slot line. ‘Deyeey Operation and Service G P oblcaton Number: 620-0002-02, ev 8 letworkintrtace ata 5 Refer to Table 12-19 and unplug the following data signal connections ‘Thile1219 GSI Data Signal Connections = To G10 port Pas Hubble connector 8 ‘Huoie connector 16 "SMIB connector Jt (opRES boa) Refer to Table 12-20 and unplug the following discrete signal connections: ‘Tiile1220 — @SI Diserste Signal Connections From = (G10 pont P37 ‘Hubble connector 2 (GSieara reacer "SME eonnactor J "EME connector J GSILCD Remove the GSI board by lifting it up at each of the standoff locations until the board is free of the player-tracking mounting plate. ‘To install the new GSI board, proceed to “Installing the GSI Board in a Hubble Configuration” on page 12-27. Removing the MGM Board from a Hubble Configuration To remove the MGM Universal Interface Board (UIB) from a Hubble configuration, refer to Figure 12-4 on page 12-5 and perform the following steps: 1 6 Refer to Table 12-21 and unplug the following network power connections: © Mersing_ Be sure to unplug the power supply from the Hubble translator board first. ie HubbleMiGM Network Power/Serial Connections Fable conneciors J18 and J8 UB Wa and UB AWE Disconnect the slot lines. Slot line connections are supplied by MGM. Disconnect the door sensors cable for the drop-door switch by unplugging the (Odyssey P37 connector from the UIB J44/B connector. Disconnect the C3 communications by unplugging the Odyssey P36 connector from the Hubble J8 connector. Disconnect any other connections to the UIB board (connections supplied by MGM), Remove the UIB by lifting it up at each of the standoff locations until the board is free of the player-tracking mounting plate. To install the new MGM UIB, proceed to “Installing the MGM Board in a Hubble Configuration” on page 1227. Chapter 2: Component Replacement Networking Haraware ‘Gayesey Operaion and Service Guide 1220 Replacing the Netware Intertace Board Removing the Caesar's Board from a Hubble Configuration ‘The Caesar's network board can be removed from the machine in the same way as the IGT network interface board. Refer to “Removing the IGT Board from a Hubble Configuration” on page 12-18. ‘To install the new Caesar’s network board, proceed to “Installing the Caesar’s Board ina Hubble Configuration” on page 12-28 Removing the Mikohn Board from a Hubble Configuration ‘To remove the Mikohn network interface board from a Hubble configuration, refer to Figure 12-4 on page 12-5 and perform the following steps: 4. Refer to Table 12-22 and unplug the following network power connections: © Wersng, Be sure to unplug the power supply from the Hubble translator board first. ‘ible 1222 MikohnvHubble Network Power Connections Caysseyunsiches powe 50h PSS Putte comes Hatbie comesor NE Tisai connector 2 Unplug the connection from the Mikohn connector J7 to the slot line, Unplug the data signal connection from GPIO port P36 to Hubble connector JB, 4. Referto Table 12-23 and unplug the following discrete signal connections: o ‘Tale12.23_Mikohn Discrete Signal Connections = a (GPIO por PST Hubble connector 2 ‘Mike care reader ‘Mikohn connector 18 ‘Mikonn oispiay Hubble connecter 37S ‘Mieone keypad ‘Mikohn connector J8 & Refer to Figure 12-4 on page 12-5 and remove the Mikchn board by lifting up the ‘board at each of the standoff locations until the board is free of the player-tracking mounting plate. To install the new Mikohn board, proceed to “Installing the Mikehn Board in a ‘Hubble Configuration” on page 12-28. ‘ayssey Operation and Service Guide Publesion Number €20-0002-02, Rex 2 Removing the Acres Rio Board from a Hubble Configuration To remove the Acres Rio network interface board (Acres DCN) from a Hubble configuration, refer to Figure 12-5 on page 12-6 and perform the following steps: 41. Refer to Table 12-24 and unplug the following network power connections: © Hering: Be sure to unplug the power supply from the Hubble translator board first, ible 12.25 Acres Rio Network Power Connections. connector 3 ‘Acres DON connector DBS7_ (Cayssey unswitched power supply Hubble connector Ja 2 Unplug the connection from the Acres DCN connector DB37 to the slot line 3 Refer fo Table 12:25 and unplug the following data signal connections: ‘Tible1225 Acres Rio/Mubble Data Signal Connections From To (GPIO por P36 Hupble connector J8 ‘Hubble connector J1é and Hubble Aares DON eonnestor DEST Connector 43 (network power) 4. Refer to Table 12-26 and unplug the following discrete signal connections: Table 1225 eres Rio Discrete Signal Connections {SPIO port P37 Hubble connector J2 Fio care reader ‘Acros connector DBT. "Acres DON connector OBTE io display & Refer to Figure 12-5 on page 126 and remove the Acres DCN board by lifting up the board until itis free of the player tracking mounting plate. ‘To install the new Acres DCN board, proceed to “Installing the Acres Rio Board in 2 Hubble Configuration” on page 12-29, Installing the Network Interface Board ‘This section contains procedures for installing the following network interface boards: + cps * Bally + IGT + Gs + MGM + Caesar's ¢ Mikohn 4 Actes Rio Chanter 1: Component Revlacerent Networking Hardware ‘Odyssey Operation and Serves Guz 2 Installing the CDS Boards in an Acres Configuration To install the CDS boards in an Acres configuration, perform the following steps: 4. Refer to Figure 12-7 on page 12-11 and align the screw holes in the player-tracking mounting plate with the standoffs on the top of the machine. Secure the plate (containing the two CDS network boards) to the machine by pushing the plate onto the standotis. 2 Refer to Table 12-27 and make the following discrete signal connections: Tibie1227 CDS Discrete Signal Connections Discrete Goo” signals (GPIO por P37 [SMIIV connector J7 ‘Gard reader iterace (COS ear reacar ‘Sentinal connecter 2 ‘Keypad inerace (COS keypad ‘Sentral connector JE (GDS cisplay nierace ‘Sentinal eonnector 77 (GBS eispiay & Refer to Table 12-28 and make the following serial data signal connections: Jable12.28 CDS/Aeres Data Signal Connections ‘Serial cata interlace _OCN connector Pt ‘Actes vanslator board connector PY ‘Serial date interface Actes translator board connecior Ja SMIIV connector J8 4 Ifthe drop door has a magnetic switch, plug the connector with the green and white wires on the door sensors cable for the drop door into pin 9 on the long ‘white connector on the left edge of the SMITV board. Ifthe drop door has a mechanical switch, plug the connector with the red and. black wires on the door sensors cable into pin 9 on the long white connector on the left edge of the SMI IV board. aq Not: Te determine the correct cable, refer tothe notes you made when you disconnected this cable. Important: Pin 9 is configured for the drop-door switch at the factory, but the casino may have reconfigured the long white connector so that the door sensor cable for the drop-door switch must be plugged into a different pin. Seral cata intertace ‘Sentinal il eonnector 4 Bank in slot ine Sonal cata niaracs ‘Sentine! ireonnecior JS Bank out sot ine ‘ayasey Operation and Service Guide Piblcaion Nurmber: €20-0002-02, Rev. B 133 & Refer to Table 12-30 and make the following network power connections: © Merses: Verify all player tracking connections are secure before plugging the power cable into the Acres translator board. ‘Tuble 12-30 CDS/Aeres Network Power Connections cr = a ‘vec oyssey Va power supply uncer SMi IV connector us rear mounting plate of Acres board) wee ‘Gayssey SV power supply ‘eres varsiaior boas +7. Install the top cap. Refer to “Installing the Top Cap” on page 2-16. 8 Configure the MMS for the CDS system. For the procedure, see “Configuring the Network” on page 420. Installing the CDS Boards in a Hubble Configuration ‘To install the CDS boards in a Hubble configuration, perform the following steps: aq) Not In jurisdictions with loss limit regulations that prevent players from losing more than $500 per day, a loss lockout board is installed. The board is provided by the casino and is located on the player-tracking mounting plate. For installation instructions, see the casino operator 4. Refer to Figure 12:2 on page 12-4 and align the screw holes in the player-tracking ‘mounting plate with the standoffs on the top of the machine. Secure the plate (containing the two CDS network boards) to the machine by pushing the plate onto the standotis. 2 Refer to Table 12-31 and make the following discrete signal connections: ‘Tule 12-51 CDS Diserete Signal Connections Destlo dour agnas GOWSSOPSOT PST SMV cnrenir v7 pr ene Tee Ga ence Tavaee C05 sad uae Sent commas aypa rsrare C8 keypad Serie Tease (CDS display inerace Sentinel connector JT Sentinel i Connector J] 3% Plug in the cable from the Hubble connector J15 to the SMI IV connector J8. 4, Ifthe drop door has a magnetic switch, plug the connector with the green and ‘white wires on the door sensors cable info pin 9 on the long white connector on the left edge of the SMIIV board. If the drop door has a mechanical switch, plug the connector with the red and black wires on the door sensors cable into pin 9 on the long white connector on the left edge of the SMI IV board. 4 Note: To determine the correct cable, refer to the notes you made when you cisconnected this cable. Important: Pin 9 is configured for the drop-door switch at the factory, but the casino may have reconfigured the long white connector so that the connector for the drop-door switch must be plugged into a different pin rapier 12: Gomponert Replacement: Networking Hardware ‘Oayssey Operation and Service Guide 1224 5 Refer to Table 12-32 and make the following slot line connections: Table1232 CDS Slot Line Connections eo io 7m ‘Sevial cable nteiace Sentinel liconnector Je Bankin sict ine “Serial cable intsrace Sentinel connector J6 Bank out sisting 6. Refer to Table 12:33 and make the following network power connections: 6 Miers Verify all player tacking connections are secure before plugging the MOVac Odyssey unswitched power supply into the Hubble connector J&. ‘TRbe 1233 CDSMubble Network Power Connections Signal From To. ‘Ves ‘Hubble connector 3 ‘SMI IV eannectorJ5 or Sentinel 9V

Вам также может понравиться