Вы находитесь на странице: 1из 17

Licensed Copy: Technical Information Services Dept .

, CNL Technical Information Services, 19 June 2004, Uncontrolled Copy, (c) BSI

British Standard

A single copy of this British Standard is licensed to


Technical Information Services Dept .

19 June 2004

This is an uncontrolled copy. Ensure use of the most


current version of this document by searching British
Standards Online at bsonline.techindex.co.uk

Licensed Copy: Technical Information Services Dept ., CNL Technical Information Services, 19 June 2004, Uncontrolled Copy, (c) BSI

BRITISH STANDARD

Specification for

Fluorescent lamps for


general lighting
service
Part 2: Specification for lamps used in
the United Kingdom not included in
BS EN 60081, BS EN 60901, BS EN 61195
and BS EN 61199

BS 1853-2:
1995

BS 1853-2:1995

Licensed Copy: Technical Information Services Dept ., CNL Technical Information Services, 19 June 2004, Uncontrolled Copy, (c) BSI

Committees responsible for this


British Standard
The preparation of this British Standard was entrusted by Technical
Committee CPL/34, Lamps and related equipment, to Subcommittee
CPL/34/1, Electric lamps, upon which the following bodies were represented:
British Lighting Association for the Preparation of Standards (BRITLAPS)
Chartered Institution of Building Services Engineers
Electricity Association
Engineering Equipment and Materials Users Association
Institution of Lighting Engineers
Lighting Industry Federation Ltd.
London Regional Transport
National Illumination Committee of Great Britain
Society of Motor Manufacturers and Traders Ltd.
The following bodies were also represented in the drafting of the standard
through subcommittees:
British Sign Association
Consumer Policy Committee of BSI
Department of Transport

This British Standard, having


been prepared under the
direction of the Electrical
Sector Board, was published
under the authority of the
Standards Board and comes
into effect on
15 December 1995
BSI 07-1999
First published April 1952
Second edition September 1956
Third edition November 1960
Fourth edition February 1967
Fifth edition June 1974
Sixth edition August 1979
Seventh edition December 1995
The following BSI references
relate to the work on this
standard:
Committee reference CPL/34/1
Draft for comment 94/2203612DC
ISBN 0 580 24729 5

Amendments issued since publication


Amd. No.

Date

Comments

BS 1853-2:1995

Licensed Copy: Technical Information Services Dept ., CNL Technical Information Services, 19 June 2004, Uncontrolled Copy, (c) BSI

Contents
Page
Committees responsible
Inside front cover
Foreword
ii
Section 1. General
1.1 Scope
1
1.2 References
1
1.3 Definitions
1
1.4 Lamp specifications
1
1.5 Sampling
1
1.6 Marking, mechanical, physical and starting characteristics
1
1.7 Requirements and conditions of test for electrical
and luminous characteristics and for life
1
1.8 Conditions of conformity
1
Section 2. Lamp data sheets
2.1 Principles of layout of data sheets
3
2.2 List of specific lamp types included in this standard
3
Figure 1 Diagrammatic drawing for location of lamp
dimensions for U-shaped lamps with G13 caps
2
List of references
Inside back cover

BSI 07-1999

BS 1853-2:1995

Licensed Copy: Technical Information Services Dept ., CNL Technical Information Services, 19 June 2004, Uncontrolled Copy, (c) BSI

Foreword
This New Edition has been prepared by Subcommittee CPL/34/1.
Following the publication of BS EN 60081, BS EN 60901, BS EN 61195 and
BS EN 61199, this new edition of BS 1853-2 has been published to take into
account the lamps, included in the previous edition, which are not covered by
those European standards.
It supersedes BS 1853-2:1979 which is withdrawn.
BS 1853-1:1990 has been superseded by BS EN 60081:1994.
A British Standard does not purport to include all the necessary provisions of a
contract. Users of British Standards are responsible for their correct application.
Compliance with a British Standard does not of itself confer immunity
from legal obligations.

Summary of pages
This document comprises a front cover, an inside front cover, pages i and ii,
pages 1 to 10, an inside back cover and a back cover.
This standard has been updated (see copyright date) and may have had
amendments incorporated. This will be indicated in the amendment table on the
inside front cover.
ii

BSI 07-1999

BS 1853-2:1995

Licensed Copy: Technical Information Services Dept ., CNL Technical Information Services, 19 June 2004, Uncontrolled Copy, (c) BSI

Section 1. General
1.1 Scope
This British Standard is applicable to those fluorescent lamps which are used in the United Kingdom and
which are not specified in BS EN 60081:1994, BS EN 60901:1994, BS EN 61195:1994 or
BS EN 61199:1994. It specifies the characteristics of fluorescent lamps for general lighting service, which
have pre-heated cathodes and which operate from 50 Hz a.c. mains with or without the aid of a starter and
in association with ballasts conforming to BS EN 60920:1991 and BS EN 60921:1991.

1.2 References
1.2.1 Normative references
This British Standard incorporates, by dated or undated reference, provisions from specific editions of
other publications. These normative references are made at the appropriate places in the text and the cited
publications are listed on the inside back cover. For dated references, only the edition cited applies; any
subsequent amendments to, or revisions of, any of the cited publication apply to this British Standard only
when incorporated in the reference by updating or revision. For undated references, the latest edition of
the cited publication applies, together with any amendments.
1.2.2 Informative references
This British Standard refers to other publications that provide information or guidance. Editions of these
publications current at the time of issue of this standard are listed on the inside back cover, but reference
should be made to the latest editions.

1.3 Definitions
For the purposes of this Part of BS 1853, the definitions given in BS EN 60081:1994, BS EN 60901:1994,
BS EN 61195:1994 and BS EN 61199:1994 apply.

1.4 Lamp specifications


Each lamp shall conform to the requirements given on the appropriate lamp data sheet. The lamp
dimensions to be controlled shall be as illustrated for circular lamps on sheet 901-IEC-3004-1 of
BS EN 60901:1994 and for U-shaped lamps in Figure 1 of this standard.

1.5 Sampling
The method of selection and the test quantities specified in BS EN 60081:1994, BS EN 60901:1994,
BS EN 61195:1994 and BS EN 61199:1994 shall apply, as appropriate.

1.6 Marking, mechanical, physical and starting characteristics


Lamp marking, dimensions and starting characteristics specified in BS EN 60081:1994,
BS EN 60901:1994, BS EN 61195:1994 and BS EN 61199:1994 shall apply, as appropriate.

1.7 Requirements and conditions of test for electrical and luminous


characteristics and for life
The requirements and conditions of test specified in BS EN 60081:1994, BS EN 60901:1994,
BS EN 61195:1994 and BS EN 61199:1994 shall apply, as appropriate.

1.8 Conditions of conformity


The conditions of conformity set out in BS EN 60081:1994, BS EN 60901:1994, BS EN 61195:1994 and
BS EN 61199:1994 shall apply, as appropriate. The test methods, ballasts, starters and torsion test holders
described in the annexes of BS EN 60081:1994, BS EN 60901:1994, BS EN 61195:1994 and
BS EN 61199:1994 shall apply, as appropriate.

BSI 07-1999

Licensed Copy: Technical Information Services Dept ., CNL Technical Information Services, 19 June 2004, Uncontrolled Copy, (c) BSI

BS 1853-2:1995

NOTE This drawing is intended only to indicate dimensions to be controlled and is to be used in conjunction with the relevant
lamp standard sheets.

Figure 1 Diagrammatic drawing for location of lamp dimensions for U-shaped


lamps with G13 capsa
a

Data sheet 7004-51 of BS 5101-1:1975

BSI 07-1999

BS 1853-2:1995

Licensed Copy: Technical Information Services Dept ., CNL Technical Information Services, 19 June 2004, Uncontrolled Copy, (c) BSI

Section 2. Lamp data sheets


2.1 Principles of layout of data sheets
The numbering system for lamp data sheets is as follows:
The first number represents the number of this publication 1853.
The second number represents the lamp data sheet number.
The third number represents the edition of the page of the data sheet. In cases where a data sheet has more
than one page it is possible for the pages to have different edition numbers with the data sheet number
remaining the same.

2.2 List of specific lamp types included in this standard


Sheet number

Lamp rating

Cap

Method of starting

Cathode type

1853-02
1853-20
1853-40

40 W
60 W
50 W

G 13
G 10q
G 13

Starter
Starter
Starterless

Pre-heated
Pre-heated
Pre-heated

BSI 07-1999

High-cathode resistance

Licensed Copy: Technical Information Services Dept ., CNL Technical Information Services, 19 June 2004, Uncontrolled Copy, (c) BSI

BS 1853-2:1995

Page 1/2

U-shaped fluorescent data sheet


Nominal dimensions

Cap

Rating

Starting

525 mm 120 mm

G13

40W

With starter

Mechanical, physical and starting requirementsFor lamp marking, tubes, dimensions, starting
requirements and conditions of conformity the appropriate requirements of BS EN 60081:1994 and/or
BS EN 61195:1994 apply.
Lamp dimensions (see Figure 1)
A

Maximum

Minimum

Maximum

Maximum

Minimum

Maximum

mm

mm

mm

mm

mm

mm

524.0

516.0

120.66

94.0

90.0

26.66

Lamp starting test


Test voltage

Ballast voltage rating

180

220

Initial readings and colour


For lamp voltage, wattage, luminous characteristics and conditions of conformity, the
requirements of BS EN 60081 apply.
Lamp electrical characteristics
Frequency

Rated wattage

Objective wattage

Voltage (r.m.s.) at lamp terminals

Nominal current

Objective

Max.

Min.

Running

Pr-heat

Hz

50

40

39

112

122

102

0.42

0.55

60

Luminous and colour characteristics


Minimum rated luminous flux

Chromaticity co-ordinates

Colour

Daylight

Full white

Warm white

lm

lm

lm

2 600

0.432

0.403

1853 02 01

BSI 07-1999

Licensed Copy: Technical Information Services Dept ., CNL Technical Information Services, 19 June 2004, Uncontrolled Copy, (c) BSI

BS 1853-2:1995

Page 2/2

U-shaped fluorescent lamp data sheet


Life test

For life test and conditions of conformity the requirements of BS EN 60081:1994 apply.
Minimum lumen maintenance
2 000 h

70 % life

80 %

70 %
Ballast

The requirements of BS EN 60921:1991 apply.


Reference ballast characteristics
Frequency

Rated wattage

Rated voltage

Calibration current

Voltage/current
ratio

Power factor

Hz

50

40

220

0.43

390

0.10

60

Equivalent
resistance of both
cathodes in series

Information for ballast design


Open circuit voltage

Pre-heating current

Min. (r.m.s.) at
starter

Max. (peak) at
lamp

Min.

Max.

Max. (r.m.s.)
voltage across
starter
terminals with
lamp operating

180

400

0.387

0.904

134

20

Information for starter design


Non-reclosure voltage

Minimum pulse voltage

140

400
1853 02 01

BSI 07-1999

Licensed Copy: Technical Information Services Dept ., CNL Technical Information Services, 19 June 2004, Uncontrolled Copy, (c) BSI

BS 1853-2:1995

Page 1/2

Circular fluorescent lamp data sheet


Nominal dimensions

Cap

Rating

Starting

406 mm

G10q

60 W

With starter

Mechanical, physical and starting requirements


For lamp marking, tubes, dimensions, starting and conditions of conformity, the appropriate
requirements of BS EN 60901:1994 and/or BS EN 61199:1994 apply.
Lamp dimensions (see sheet 901-IEC-3004-1 of BS EN 60901:1994)
A

C and D

D1

Max.

Min.

Max.

Min.

Max.

Min.

Max.

Min.

mm

mm

mm

mm

mm

mm

mm

mm

347.7

341.3

347.7

338.1

412.8

400.0

34.1

29.4

Lamp starting test


Test voltage

Ballast voltage rating

180

220
Initial readings and colour

For lamp voltage, wattage, luminous characteristics and conditions of conformity, the requirements
of BS EN 60901 apply.
Lamp electrical characteristics
Frequency

Rated wattage

Objective
wattage

Voltage (r.m.s.) at lamp terminals

Nominal current

Objective

Max

Min.

Running

Pre-heat

Hz

50

60

58.0

92

102

82

0.750

1.150

60

60

Luminous and colour characteristics


Minimum rated luminous flux

Chromaticity co-ordinates

Colour

Daylight

Full white

Warm
white

lm

lm

lm

3 000

3 400

3 500

0.309

0.327

0.368

0.371

0.435

0.402

1853 20 01

BSI 07-1999

Licensed Copy: Technical Information Services Dept ., CNL Technical Information Services, 19 June 2004, Uncontrolled Copy, (c) BSI

BS 1853-2:1995

Page 2/2

Circular fluorescent lamp data sheet


Life test
For life test, the requirements of BS EN 60901:1994 apply.
Minimum lumen maintenance
2 000 h

70 % life

75 %

60 %
Ballast

The requirements of BS EN 60920:1991 and BS EN 60921:1991 apply.


Reference ballast characteristics
Frequency

Rated wattage

Rated voltage

Calibration
current

Voltage/current ratio

Power factor

Hz

50

65

220

0.67

240

0.10

60

Equivalent
resistance of
both cathodes
in series

Information for ballast design


Open circuit voltage

Pre-heating current

Min. (r.m.s.)
at starter

Max. (peak) at
lamp

Min.

Max.

Max. (r.m.s.) voltage


across starter
terminals with lamp
operating

180

400

0.603

1.410

132

25

Information for starter design


Non-enclosure

Minimum pulse voltage

130

400
1853 20 01

BSI 07-1999

Licensed Copy: Technical Information Services Dept ., CNL Technical Information Services, 19 June 2004, Uncontrolled Copy, (c) BSI

BS 1853-2:1995

Page 1/2

Linear Fluorescent lamp data sheet


Nominal dimensions

Cap

Rating

Starting

Cathode

1 500 mm 25 mm

G13

50 W

Starterless

High resistance

Mechanical, physical and starting requirements


For lamp marking, tubes, dimensions, starting requirements and conditions of conformity,
BS EN 60081:1994 and BS EN 61195:1994 apply.
Lamp dimensions (see sheet 81-IEC-0001-1 of BS EN 60081:1994)
A

Max.

Max.

Min.

Max.

Max.

mm

mm

mm

mm

mm

1 500

1507.1

1504.7

1514.2

28.0

Lamp starting test


Open circuit voltage at lamp terminals for
starting test

Ballast rating for starting test


Wattage

Voltage

270

50

240

Initial readings and colour


For lamp voltage and wattage, luminous characteristics, cathode characteristics, and conditions
of conformity, the requirements of BS EN 60081:1994 apply.
Lamp electrical characteristics
Frequency

Rated
wattage

Objective
wattage

Hz

50
60

Voltage (r.m.s.) at lamp terminals

Nominal running
current

Objective

Max.

Min.

50

48

155

170

140

0.37

Luminous and colour characteristics


Minimum rated luminous flux

Chromaticity co-ordinates

Colour

Daylight

Full
white

Warm
white

lm

lm

lm

3 000

3 250

0.365

0.373

0.432

0.403

1853 40 01

BSI 07-1999

Licensed Copy: Technical Information Services Dept ., CNL Technical Information Services, 19 June 2004, Uncontrolled Copy, (c) BSI

BS 1853-2:1995

Page 2/2

Linear Fluorescent lamp data sheet


Cathode characteristics
Cathode

Test voltage

Resistance of each cathode


7

Objective

Min.

19

High resistance

Life test
For life test and conditions of conformity the requirements of BS EN 60081:1994 apply.
Minimum lumen maintenance
2 000 h

70 % life

80 %

70 %
Ballast

The requirements of BS EN 60920:1991 and BS EN 60291:1991 apply.


Reference ballast characteristics
Frequency

Rated wattage

Rated
voltage

Calibration current

Voltage/current
ratio

Power factor

Hz

50

50

350

0.37

735

0.12

60

Information for ballast design


Open circuit voltage at lamp terminals
Min. (r.m.s.)

Max. (peak)

270

580

Maximum current in any


lead to cathode

Pre-heat cathode voltage


Min.

Max.

0.63

6.5

11.0

1853 40 01

BSI 07-1999

Licensed Copy: Technical Information Services Dept ., CNL Technical Information Services, 19 June 2004, Uncontrolled Copy, (c) BSI

10

blank

BS 1853-2:1995

Licensed Copy: Technical Information Services Dept ., CNL Technical Information Services, 19 June 2004, Uncontrolled Copy, (c) BSI

List of references
Normative references
BSI Standards Publications
BRITISH STANDARDS INSTITUTION, London

BS EN 60081:1994, Specification for tubular fluorescent lamps for general lighting service.
BS EN 60901:1994, Specification for single-capped fluorescent lamps. Safety and performance
requirements.
BS EN 60920:1991, Specification for ballasts for tubular fluorescent lamps. General and safety
requirements.
BS EN 60921:1991, Specification for ballasts for tubular fluorescent lamps. Performance requirements.
BS EN 61195:1994, Double-capped fluorescent lamps. Safety specifications.
BS EN 61199:1994, Single-capped fluorescent lamps. Safety specifications.

BSI 07-1999

Licensed Copy: Technical Information Services Dept ., CNL Technical Information Services, 19 June 2004, Uncontrolled Copy, (c) BSI

BS 1853-2:
1995

BSI British Standards Institution


BSI is the independent national body responsible for preparing
British Standards. It presents the UK view on standards in Europe and at the
international level. It is incorporated by Royal Charter.
Revisions
British Standards are updated by amendment or revision. Users of
British Standards should make sure that they possess the latest amendments or
editions.
It is the constant aim of BSI to improve the quality of our products and services.
We would be grateful if anyone finding an inaccuracy or ambiguity while using
this British Standard would inform the Secretary of the technical committee
responsible, the identity of which can be found on the inside front cover.
Tel: 020 8996 9000. Fax: 020 8996 7400.
BSI offers members an individual updating service called PLUS which ensures
that subscribers automatically receive the latest editions of standards.
Buying standards
Orders for all BSI, international and foreign standards publications should be
addressed to Customer Services. Tel: 020 8996 9001. Fax: 020 8996 7001.
In response to orders for international standards, it is BSI policy to supply the
BSI implementation of those that have been published as British Standards,
unless otherwise requested.
Information on standards
BSI provides a wide range of information on national, European and
international standards through its Library and its Technical Help to Exporters
Service. Various BSI electronic information services are also available which give
details on all its products and services. Contact the Information Centre.
Tel: 020 8996 7111. Fax: 020 8996 7048.
Subscribing members of BSI are kept up to date with standards developments
and receive substantial discounts on the purchase price of standards. For details
of these and other benefits contact Membership Administration.
Tel: 020 8996 7002. Fax: 020 8996 7001.
Copyright
Copyright subsists in all BSI publications. BSI also holds the copyright, in the
UK, of the publications of the international standardization bodies. Except as
permitted under the Copyright, Designs and Patents Act 1988 no extract may be
reproduced, stored in a retrieval system or transmitted in any form or by any
means electronic, photocopying, recording or otherwise without prior written
permission from BSI.
This does not preclude the free use, in the course of implementing the standard,
of necessary details such as symbols, and size, type or grade designations. If these
details are to be used for any other purpose than implementation then the prior
written permission of BSI must be obtained.

BSI
389 Chiswick High Road
London
W4 4AL

If permission is granted, the terms may include royalty payments or a licensing


agreement. Details and advice can be obtained from the Copyright Manager.
Tel: 020 8996 7070.