RoHS compliant
HL RELAYS
FEATURES
TYPICAL APPLICATIONS
ORDERING INFORMATION
HL
Contact arrangement
1: 1 Form C
2: 2 Form C
Terminal arrangement
H:
Plug-in type
L:
Plug-in type with LED indication
HP: PC board type
PL: PC board type with LED indication
HTM: TM type
Nominal coil voltage
AC 6, 12, 24, 48, 100 (100/110), 120 (110/120),
200 (200/220), 240 (220/240) V
DC 6, 12, 24, 48, 100 (100/110) V
Surge absorber
*D: with diode
Contact material
F: AgSnO2 type
Notes: 1. Certified by C-UL, CSA and TV
Please inquire about TV approved products.
2. *Diode type is available. (DC coil Plug-in type with LED indication only)
3. The LED indication color is green for the DC coil and red for the AC coil.
ASCTB114E 201408-T
HL
TYPES
1. Plug-in type
Nominal coil
voltage
6V AC
12V AC
24V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
6V DC
12V DC
24V DC
48V DC
100/110V DC
2 Form C
Part No.
HL2-H-AC6V-F
HL2-H-AC12V-F
HL2-H-AC24V-F
HL2-H-AC48V-F
HL2-H-AC100V-F
HL2-H-AC120V-F
HL2-H-AC200V-F
HL2-H-AC240V-F
HL2-H-DC6V-F
HL2-H-DC12V-F
HL2-H-DC24V-F
HL2-H-DC48V-F
HL2-H-DC100V-F
6V DC
12V DC
24V DC
48V DC
100/110V DC
1 Form C
Part No.
HL1-L-DC6V-D-F
HL1-L-DC12V-D-F
HL1-L-DC24V-D-F
HL1-L-DC48V-D-F
HL1-L-DC100V-D-F
6V AC
12V AC
24V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
6V DC
12V DC
24V DC
48V DC
100/110V DC
1 Form C
Part No.
HL1-L-AC6V-F
HL1-L-AC12V-F
HL1-L-AC24V-F
HL1-L-AC48V-F
HL1-L-AC100V-F
HL1-L-AC120V-F
HL1-L-AC200V-F
HL1-L-AC240V-F
HL1-L-DC6V-F
HL1-L-DC12V-F
HL1-L-DC24V-F
HL1-L-DC48V-F
HL1-L-DC100V-F
2 Form C
Part No.
HL2-L-AC6V-F
HL2-L-AC12V-F
HL2-L-AC24V-F
HL2-L-AC48V-F
HL2-L-AC100V-F
HL2-L-AC120V-F
HL2-L-AC200V-F
HL2-L-AC240V-F
HL2-L-DC6V-F
HL2-L-DC12V-F
HL2-L-DC24V-F
HL2-L-DC48V-F
HL2-L-DC100V-F
Nominal coil
voltage
2 Form C
Part No.
HL2-L-DC6V-D-F
HL2-L-DC12V-D-F
HL2-L-DC24V-D-F
HL2-L-DC48V-D-F
HL2-L-DC100V-D-F
4. PC board type
Nominal coil
voltage
6V AC
12V AC
24V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
6V DC
12V DC
24V DC
48V DC
100/110V DC
1 Form C
Part No.
HL1-HP-AC6V-F
HL1-HP-AC12V-F
HL1-HP-AC24V-F
HL1-HP-AC48V-F
HL1-HP-AC100V-F
HL1-HP-AC120V-F
HL1-HP-AC200V-F
HL1-HP-AC240V-F
HL1-HP-DC6V-F
HL1-HP-DC12V-F
HL1-HP-DC24V-F
HL1-HP-DC48V-F
HL1-HP-DC100V-F
2 Form C
Part No.
HL2-HP-AC6V-F
HL2-HP-AC12V-F
HL2-HP-AC24V-F
HL2-HP-AC48V-F
HL2-HP-AC100V-F
HL2-HP-AC120V-F
HL2-HP-AC200V-F
HL2-HP-AC240V-F
HL2-HP-DC6V-F
HL2-HP-DC12V-F
HL2-HP-DC24V-F
HL2-HP-DC48V-F
HL2-HP-DC100V-F
1 Form C
Part No.
HL1-PL-AC6V-F
HL1-PL-AC12V-F
HL1-PL-AC24V-F
HL1-PL-AC48V-F
HL1-PL-AC100V-F
HL1-PL-AC120V-F
HL1-PL-AC200V-F
HL1-PL-AC240V-F
HL1-PL-DC6V-F
HL1-PL-DC12V-F
HL1-PL-DC24V-F
HL1-PL-DC48V-F
HL1-PL-DC100V-F
6. TM type
2 Form C
Part No.
HL2-PL-AC6V-F
HL2-PL-AC12V-F
HL2-PL-AC24V-F
HL2-PL-AC48V-F
HL2-PL-AC100V-F
HL2-PL-AC120V-F
HL2-PL-AC200V-F
HL2-PL-AC240V-F
HL2-PL-DC6V-F
HL2-PL-DC12V-F
HL2-PL-DC24V-F
HL2-PL-DC48V-F
HL2-PL-DC100V-F
Nominal coil
voltage
6V AC
12V AC
24V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
6V DC
12V DC
24V DC
48V DC
100/110V DC
1 Form C
Part No.
HL1-HTM-AC6V-F
HL1-HTM-AC12V-F
HL1-HTM-AC24V-F
HL1-HTM-AC48V-F
HL1-HTM-AC100V-F
HL1-HTM-AC120V-F
HL1-HTM-AC200V-F
HL1-HTM-AC240V-F
HL1-HTM-DC6V-F
HL1-HTM-DC12V-F
HL1-HTM-DC24V-F
HL1-HTM-DC48V-F
HL1-HTM-DC100V-F
2 Form C
Part No.
HL2-HTM-AC6V-F
HL2-HTM-AC12V-F
HL2-HTM-AC24V-F
HL2-HTM-AC48V-F
HL2-HTM-AC100V-F
HL2-HTM-AC120V-F
HL2-HTM-AC200V-F
HL2-HTM-AC240V-F
HL2-HTM-DC6V-F
HL2-HTM-DC12V-F
HL2-HTM-DC24V-F
HL2-HTM-DC48V-F
HL2-HTM-DC100V-F
ASCTB114E 201408-T
HL
RATING
1. Coil data
1) AC coils
Nominal coil
voltage
6V AC
50Hz
224
60Hz
200
50Hz
12V AC
24V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
111
56
28
13.4/14.7
12.2/13.5
6.7/7.4
100
50
25
12/13.2
10.9/11.9
6/6.6
60Hz
1.3
1.2
Pick-up voltage
(at 20C 68F)
80%V or less of
nominal voltage
(Initial)
Drop-out voltage
(at 20C 68F)
30%V or more of
nominal voltage
(Initial)
Max. applied
voltage
(at 70C 158F)
Inductance (H)
When drop-out
When operating
0.078
0.074
0.312
1.243
4.974
23.75
27.19
85.98
0.295
1.181
4.145
20.63
25.57
81.76
110%V of
nominal voltage
Notes: 1. The relay operates in a range of 80% to 110% V of the nominal voltage, but ideally, in consideration of temporary voltage fluctuations, it should be operated at the
rated voltage.
In particular, for AC operation, if the applied voltage drops to 80% V or more below the nominal voltage, humming will occur and a large current will flow leading
possibly to coil burnout.
2. The maximum applied voltage is the maximum voltage fluctuation value for the coil power supply. This value is not a permissible value for continuous operation.
(This value differs depending on the ambient temperature. Please contact us for details.)
12V DC
24V DC
48V DC
100/110V DC
75
37
18.5
10
Nominal operating
power (W)
0.9
1.0
Coil resistance
()
40
Pick-up voltage
(at 20C 68F)
Drop-out voltage
(at 20C 68F)
160
650
2,600
10,000
80%V or less of
nominal voltage
(Initial)
10%V or more of
nominal voltage
(Initial)
110%V of
nominal voltage
2. Specifications
Characteristics
Contact
Rating
Item
Contact resistance (Initial)
Contact material
Nominal switching capacity*4
Min. switching capacity (Reference value)*1
Insulation resistance (Initial)
Between open contacts
Between contact sets
Between contact and coil
Temperature rise (coil)
Breakdown voltage
(Initial)
Electrical
characteristics
Mechanical
characteristics
Expected life
AC load
Electrical
DC load
Conditions
Unit weight
Specifications
Max. 50 m (By voltage drop 6 V DC 1A)
AgSnO2 type
1 Form C: 15A 125V AC, 10A 250V AC (resistive load)
2 Form C: 10A 250V AC (resistive load)
100mA 5V DC
Min. 100M (at 500V DC) Measurement at same location as Breakdown voltage section.
1,000 Vrms for 1min. (Detection current: 10mA)
1,500 Vrms for 1min. (Detection current: 10mA)
2,000 Vrms for 1min. (Detection current: 10mA)
Max. 80C 176F (By resistive method, nominal voltage)
DC type/AC type: Max. 25ms
(Nominal coil voltage applied to the coil, excluding contact bounce time.)
DC type/AC type: Max. 25ms
(Nominal coil voltage applied to the coil, excluding contact bounce time.) (without diode)
Min. 196 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10s.)
Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 1 mm (Detection time: 10s.)
10 to 55 Hz at double amplitude of 2 mm
AC type: 5107 (at 180 times/min.), DC type: 108 (at 180 times/min.)
1 Form C: 15A 125V AC, 10A 250V AC resistive load (cos=1) Life switching cycle: Min. 5105
2 Form C: 10A 250V AC resistive load (cos=1) Life switching cycle: Min. 3105
1 Form C: 3A 30V DC resistive load (cos=1) Life switching cycle: Min. 5105
2 Form C: 3A 30V DC resistive load (cos=1) Life switching cycle: Min. 5105
Ambient temperature: 50C to +70C 58F to +158F (Without LED indication);
50C to +60C 58F to +140F (With LED indication)
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
20 times/min. (at max. rating)
Approx. 35g 1.23 oz
Notes: If integrating into electrical appliances that will be subject to compliance to the Electrical Appliance and Material Safety Law, please use in an ambient temperature
between 50C to +40C 58F to +104F (AC type).
*1. This value can change due to the switching frequency, environmental conditions and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. For the AC coil types, the operate/release time will differ depending on the phase.
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
*4. When using the socket, be sure to verify the max. continuous current.
ASCTB114E 201408-T
HL
REFERENCE DATA
Switching capacity range (2 Form C)
AC resistive load
15
10
1 DC inductive
load (L/R=7ms)
AC resistive load
Contact current, A
Contact current, A
AC inductive
load (cos=0.4)
DC resistive
load
0.1
10
100
10
1 DC inductive
load (L/R=7ms)
AC inductive
load (cos=0.4)
DC resistive
load
0.1
10
500 1,000
100
500 1,000
Contact voltage, V
Contact voltage, V
ON
OFF
ON
OFF
260V
+
+
12V DC
To digital
memory
12V DC
To digital
memory
1. Plug-in type
1 Form C
CAD Data
External dimensions
CAD Data
27.2
1.071
20.8
.819
2
3
6
7
35.4
1.394
LED AC type
0.5
.020
2
3
10
.394
2
3
6
8
(+)
8
LED DC type
2
14.2
.559
1.2
.047
6.35
.250
()
7
7
( )
3.75
.148
4.6
.181
6
.236
7.15
.281
8
( )
7
()
8
(+)
ASCTB114E 201408-T
HL
2 Form C
External dimensions
CAD Data
20.8
.819
27.2
1.071
()
7
35.4
1.394
1.2
.047
6.35
.250
LED AC type
0.5
.020
Compatible with tab terminal
#187 series receptacle.
10
.394
1
14.2
.559
()
( )
( )
8
(+)
2. PC board type
1 Form C
External dimensions
CAD Data
LED DC type
3.7
.146
4.7
.185
6
.236
7.3
.287
(+)
8
20.8
.819
27.2
1.071
2
3
6
7
35.4
1.394
LED AC type
1.2
.047
5
.197
3.5
.138
1.5
.059
LED DC type
2
2
3
0.5
.020
8
( )
( )
()
8
(+)
10
.394
2
3
6
7
3.75
.148
4.6
.181
6
.236
7.15
.281
10
.394
4.6
.181
14.2
.559
6
.236 R2
R.079
4
.157
14.2
.559
17.75
.699
8.5
.335
7.15
.281
ASCTB114E 201408-T
HL
2 Form C
External dimensions
CAD Data
20.8
.819
27.2
1.071
35.4
1.394
LED AC type
1.2
.047
5
.197
3.5
.138
1.5
.059
0.5
.020
LED DC type
8
( )
8
(+)
()
( )
10
.394
1
3.7
.146
4.7
.185
6
.236
7.3
.287
10
.394
14.2
.559
1.25
.049
1.25
.049 2
.079
1.25
.049 2
.079
18
.709
13.3
.524
4
.157
R2
R.079
7.3
.287
14.2
.559
R2
R.079
4
4
3. TM type
1 Form C
External dimensions
CAD Data
43
1.693
20.6
.811
2
.079
3
6
7
34.4
1.354
1.2
.047
6.35
.250
37.6
1.470
6
7
23
.906
37.6
1.470
0.5
.020
3.6
.142
3.75
.148
4.6
.181
6
.236 37.6
7.15 1.480
.281
21
21
.827 2 .827
.079
ASCTB114E 201408-T
HL
2 Form C
External dimensions
CAD Data
43
1.693
20.6
.811
2
.079
34.4
1.354
6.35
.250
37.6
1.470
37.6
1.470
21
21
.827 2 .827
.079
23
.906
0.5
.020
3.6
.142
1.2
.047
3.7
.146
4.7
.185
6
37.6
.236 1.480
7.3
.287
SAFETY STANDARDS
1. Standard type (Plug-in type except with diode, PC board type, TM type)
Contact
arrangement
1 Form C
2 Form C
UL/C-UL (Recognized)
File No.
Contact rating
15A 250V AC
E43028*1
1/3HP 125, 250V AC
10A 30V DC
10A 250V AC
E43028*1
1/3HP 125, 250V AC
10A 30V DC
File No.
CSA (Certified)
Contact rating
CSA standard
certified by C-UL
CSA standard
certified by C-UL
TV rating (UL/CSA)
File No.
Rating
UL: E43149
NOTV-5
CSA: LR26550 NCTV-2
etc.
UL: E43149
NOTV-4
CSA: LR26550 NCTV-2
etc.
File No.
B1305
13461 341
B1305
13461 341
TV rating
Rating
15A 125V AC (cos =1.0)
10A 250V AC (cos =1.0)
10A 30V DC (L/R=0ms)
10A 250V AC (cos =1.0)
10A 30V DC (L/R=0ms)
2 Form C
UL/C-UL (Recognized)
File No.
Contact rating
15A 250V AC
E43028*1
1/3HP 125, 250V AC
10A 30V DC
10A 250V AC
E43028*1
1/3HP 125, 250V AC
10A 30V DC
File No.
CSA (Certified)
Contact rating
CSA standard
certified by C-UL
CSA standard
certified by C-UL
TV rating (UL/CSA)
File No.
Rating
File No.
B1305
13461 341
B1305
13461 341
TV rating
Rating
15A 125V AC (cos =1.0)
10A 250V AC (cos =1.0)
10A 30V DC (L/R=0ms)
10A 250V AC (cos =1.0)
10A 30V DC (L/R=0ms)
NOTES
1. For cautions for use, please read
General Application Guidelines.
ASCTB114E 201408-T
HL RELAYS
ACCESSORIES
FEATURES
3. A hold-down clip is included in the
package.
HC/HL-LEAF-SPRING-MK
TYPES
1. Sockets
Type
Plug-in socket
PC board socket
No. of poles
1-pole
2-pole
1-pole
2-pole
Item
Part No.
HL1-SS-K
HL2-SS-K
HL1-PS-K
HL2-PS-K
HL1 socket
HL2 socket
HL1 PC board socket
HL2 PC board socket
2. Terminal sockets
Type
No. of poles
1/2-pole (common)
Item
HK2-DIN rail terminal socket
HK2-DIN rail terminal socket (Finger protect type)
Part No.
AHKA21
AHKA21P
RATING
Specifications (Sockets and DIN rail terminal sockets)
Item
Type
Contact arrangement
Max. continuous current
(Ambient temperature:
-50 to +70C -58 to +158F)
Breakdown Between open contacts
voltage
Between contact sets
(Initial)
Between contact and coil
Initial insulation resistance
Performance
HL1
Plug-in socket
HL1
PC board socket
1 Form C (1-pole)
10A
HL2
Plug-in socket
HL2
PC board socket
2 Form C (2-pole)
10A
10A
HK2-DIN rail
terminal socket
(Finger protect
type)
2 Form C (1/2-pole common)
HK2-DIN rail
terminal socket
10A
15A
15A
Note: When using a 1-pole HL relay on 1 Form C socket (HL1 Plug-in and HL1 PC board), please use within a range that does not exceed the max. continuous current (10A).
ASCTB115E 201408-T
HL RELAY ACCESSORIES
DIMENSIONS (mm inch)
CAD Data
CAD Data
25.5
1.004
Hold-down clip
29.4
1.157
Side-by-side installation
25.8
1.016
8.9
.350
25.8
1.016
5.9
.232
21.6
.850
21.6
.850
CAD Data
21.2
.835
29.4
1.157
2.0
.079
Hold-down clip
Note: The external and mounting
dimensions of HL2 PC
board type socket are the
same for HL1 PC board type
socket. Only the number of
terminals varies.
1.0
.039
11.2
.441
16.2
.638
13.2
.520
10
.394
15.3
.602
10
.394
2 Form C
10
.394
4.7
.185
6.75
.266
17.45
12.75 .687
.502
10
.394
15.3
.602
6.75
.266
17.45
.687
(6.6)
(.260)
17.25
.679
(5.3)
(.209)
17.45
.687
15.3
.602
7.9
.311
15.3
.602
ASCTB115E 201408-T
HL RELAY ACCESSORIES
3. HK2-DIN rail terminal socket
(AHKA21)
CAD Data
2-4.56 2-.1776
mounting holes
External dimensions
7
.276
Schematic
Max. 30
Max. 1.181
M3.5 .138
terminal screw
3.4
.134
680.3
2.677.012
35.4
1.394
Max. 78.5
Max. 3.091
Max. 28.5
Max. 1.122
8
.315
7
.276
M3.5 .138
terminal screw
190.2
.748.008
Schematic
Max. 33
Max. 1.299
30
1.181
3.4
.134
680.3
2.677.012
35.4
1.394
Max. 78.5
Max. 3.091
8
.315
Max. 28.5
Max. 1.122
General tolerance:
0.5 .020
190.2
.748.008
ASCTB115E 201408-T