Вы находитесь на странице: 1из 3

Principal Data (EN)

Industrial Air Division

*** For internal use only ***

Product Company Airpower

AQ30 - AQ55 / 60Hz / 157 psi / AC

PRODUCT DEFINITION
Model
Supply voltage
Working pressure
Frequency
Cooling

AQ30
460 V
157 psi
60 Hz
AC

AQ37
460 V
157 psi
60 Hz
AC

AQ45
460 V
157 psi
60 Hz
AC

AQ55
460 V
157 psi
60 Hz
AC

14.5
0
68
68
149.4
3560

14.5
0
68
68
149.4
3565

14.5
0
68
68
149.4
3570

14.5
0
68
68
149.4
3572

psia
%
F
F
psig
rpm

156.6
154.7
104
35.6
58
3280.8

156.6
153.3
104
35.6
58
3280.8

156.6
153.3
104
35.6
58
3280.8

156.6
154.7
104
35.6
58
3280.8

psig
psig
F
F
psig
Ft

REFERENCE CONDITIONS
Absolute inlet pressure
Relative humidity
Air inlet temperature
Cooling medium inlet temperature
Effective working pressure
Motor shaft speed

LIMITATIONS
Maximum effective working pressure
Workplace
Workplace FF
Maximum allowable inlet temperature
Minimum ambient temperature
Minimum effective working pressure
Maximum altitude

PERFORMANCE DATA (1)


Free Air Delivery (2)
Workplace
Workplace FF
Workplace
Workplace FF
Workplace
Workplace FF
Workplace
Workplace FF

58
58
87
87
102
102
157
149

psig
psig
psig
psig
psig
psig
psig
psig

154.6
154.3
150.6
150.4
149.5
149.3
150.2
149.8

187.4
187.0
184.4
184.1
183.3
183.0
181.2
181.2

223.6
223.3
221.0
220.7
219.6
219.3
213.9
214.3

276.2
276.0
272.9
272.6
270.7
270.3
258.7
260.1

cfm
cfm
cfm
cfm
cfm
cfm
cfm
cfm

Total electrical power input


Workplace
Workplace FF
Workplace
Workplace FF
Workplace
Workplace FF
Workplace
Workplace FF

58
58
87
87
102
102
157
149

psig
psig
psig
psig
psig
psig
psig
psig

26.0
27.8
29.5
31.4
31.5
33.4
39.5
40.3

31.4
33.4
35.6
37.8
38.0
40.2
47.3
48.3

39.7
41.9
45.0
47.3
47.8
50.1
58.7
59.6

50.1
52.2
56.7
58.8
60.2
62.4
73.7
74.2

kW
kW
kW
kW
kW
kW
kW
kW

Total specific energy requirement (3)


Workplace
Workplace FF
Workplace
Workplace FF
Workplace
Workplace FF
Workplace
Workplace FF

58
58
87
87
102
102
157
149

psig
psig
psig
psig
psig
psig
psig
psig

16.9
18.1
19.6
20.9
21.1
22.4
26.3
27.0

16.8
17.9
19.4
20.6
20.8
22.0
26.2
26.7

17.8
18.8
20.4
21.4
21.8
22.9
27.5
27.8

18.2
19.0
20.8
21.6
22.3
23.1
28.5
28.6

kW/100cfm
kW/100cfm
kW/100cfm
kW/100cfm
kW/100cfm
kW/100cfm
kW/100cfm
kW/100cfm

1/3

AML - 2900 7003 89 - Ed. 00

Principal Data (EN)

Industrial Air Division

*** For internal use only ***

Fan(s) electrical power input


Shaft power input at effective working pressure stated
Workplace
58 psig
Workplace FF
58 psig
Workplace
87 psig
Workplace FF
87 psig
Workplace
102 psig
Workplace FF
102 psig
Workplace
157 psig
Workplace FF
149 psig

2.4

2.4

4.6

4.6

kW

21.9
22.1
25.1
25.3
26.9
27.2
34.3
33.6

27.0
27.4
30.9
31.4
33.1
33.6
41.8
41.2

32.9
33.5
37.8
38.4
40.4
41.1
50.7
50.0

42.6
43.0
48.8
49.2
52.1
52.5
64.7
63.5

kW
kW
kW
kW
kW
kW
kW
kW

Specific shaft input requirement based on shaft input


Workplace
58 psig
Workplace FF
58 psig
Workplace
87 psig
Workplace FF
87 psig
Workplace
102 psig
Workplace FF
102 psig
Workplace
157 psig
Workplace FF
149 psig

14.2
14.3
16.7
16.9
18.1
18.2
22.9
22.5

14.4
14.7
16.8
17.1
18.1
18.4
23.1
22.8

14.7
15.0
17.1
17.4
18.4
18.8
23.7
23.3

15.5
15.6
17.9
18.1
19.3
19.5
25.1
24.5

kW/100cfm
kW/100cfm
kW/100cfm
kW/100cfm
kW/100cfm
kW/100cfm
kW/100cfm
kW/100cfm

18
7
68 / 3

18
7
69 / 3

18
7
71 / 3

18
7
72 / 3

a+ F
a+ F

11.2
12.8

12.8
14.5

15.4
17.0

20.7
22.4

kW
kW

1
2589
92.4
88
13.2
76

1
3128
93
90
13.2
76

1
3729
93.6
90
13.2
83

1
4617
93.6
90
13.2
83

rpm
%
%
gal
%

5466.7
6021.9
1 1/2
0.24
0.16
63
8.0
3.2
6.0

5615.0
6280.4
1 1/2
0.24
0.16
63
8.0
3.2
6.0

7310.1
7975.5
1 1/2
0.24
0.16
63
8.0
3.2
6.0

7416.1
8081.4
1 1/2
0.24
0.16
63
8.0
3.2
6.0

cfm
cfm
G
in
in
M
Ft
Ft
Ft

2702.9
2910.1
8.8
3.7
6.8
8.8
3.7
7.0
223
230.6

2910.1
3075.4
8.8
3.7
6.8
8.8
3.7
7.0
223
230.6

2912.3
3121.7
8.8
3.7
6.8
8.8
3.7
7.0
223
230.6

3038.0
3300.3
8.8
3.7
6.8
8.8
3.7
7.0
223
230.6

lb
lb
Ft
Ft
Ft
Ft
Ft
Ft
F
F

2857.2
3064.4

3064.4
3229.8

3066.6
3276.1

3192.3
3454.6

lb
lb

3143.8
3351.0

3351.0
3516.4

3353.2
3562.7

3478.9
3741.2

lb
lb

Compressed air temperature at outlet valve


Workplace
Workplace FF
Mean Sound pressure level with uncertainty (5)
Total Electrical Power input at unload
Workplace
Workplace FF

DESIGN DATA
Number of Compression Stages
Male rotor speed
Drive motor efficiency at full load
Drive motor efficiency at no load
Water capacity (approx.)
Fan motor efficiency
Cooling air flow referred to air inlet grating compressor
Workplace
Workplace FF
Dimension of compressed air outlet valve (threaded)
Condensate drainpipes automatic drain OD
Condensate drainpipes automatic drain ID
Electrical cable passage
Canopy length
Canopy width
Canopy heigth
Net Mass floor mounted
Workplace
Workplace FF
Shipping Length
Shipping Width
Shipping Height
ECU Length
ECU Width
ECU Height
Shipping Volume
ECU Volume
Shipping mass Europe
Workplace
Workplace FF
Shipping mass Overseas
Workplace
Workplace FF

2/3

AML - 2900 7003 89 - Ed. 00

Principal Data (EN)

Industrial Air Division

*** For internal use only ***

INTEGRATED DRYER
Integrated dryer type
Pressure dew point Full Feature a=68 F and Rh=100%
Dryer pressure drop
Total power consumption at full load (a=68F and
Rh=100%(including fan))
Compressed air outlet temperature (a = 68F, Rh = 100%)
Cooling air flow
Heat dissipated by cooling air (a=68 F, Rh=100%)
Refrigerant type
Refrigerant total amount

ID100
37.4
1.9

ID136
37.4
3.3

ID136
37.4
3.3

ID145
37.4
1.9

F
psi

1.6

1.6

1.6

1.7

kW

77.0
555.1
3.6
R410a
1.9

82.4
665.3
4.3
R410a
2.2

82.4
665.3
4.3
R410a
2.2

86.0
665.3
4.6
R410a
2.3

F
cfm
kW
lb

REMARKS
(1) Unless otherwise stated, at reference conditions.
All values given with a tolerance according to specified.
Codes are guaranteed; all other values are to be considered typical.
(2) Free Air Delivery measured according ISO 1217 ed. 4 2009, annex C
FAD < 250 l/s
Tolerance
5%
FAD > 250 l/s
Tolerance
4%
(3) Specific Energy Requirement measured according ISO 1217 ed. 4 2009, annex C
FAD < 250 l/s
Tolerance
6%
FAD > 250 l/s
Tolerance
5%
(4) Power requirement at zero volume flow rate measured according ISO 1217 ed. 4 2009, annex C
Tolerance
10%
(5) Measured according to ISO 2151: 2004 using ISO 9614/2 (sound intensity method).
The International ISO 1217 ed. 4 2009 standard refers to following standards :
- ISO 5167
- British BS 1571 Part 2
- ISO 9300
- American ASME PTC9
- German DIN 1950

3/3

AML - 2900 7003 89 - Ed. 00