Вы находитесь на странице: 1из 2

LIMCON V3.63.1.

21 {0}
Connection: C1
Type: Base Plate
1: Pinned base plate
Units: SI metric
Design code: ANSI/AISC 360 (ASD)
Column: Mark=C1 Section=W15X8X.5X.5
Grade=A36
d =
381 mm
Root rad. =
3 mm
Fyf =
248 MPa
b =
203 mm
Area =
9669
Fyw =
248 MPa
tf =
12.7 mm
Sx = 1186898
Fu =
400 MPa
tw =
12.7 mm
Zx = 1321010
.Section shear strength . . . . .
479.4 kN
A360 (G2-1) .Section tension strength . . . . 1437.1 kN
A360-(D2-1)
.Section compression strength . . 1437.1 kN
A360 E7
Base plate:
420x240x16

Gr./Fy/Fu=A36/24/400MPa

Welds:
10 FW/414MPa all around column.
Bolts:
4 x M20 A307/N anchor bolts.
Bolt hole dia. . . . . . . . . .
40 mm
No. bolt rows = 2
No. bolt cols. = 2
Spacing of outer bolts, sg = 160 in XX direction.
Spacing of outer bolts, sp = 240 in YY direction.
Embedment length = 300, no hook.
Shear capacity of bolts NOT considered.
No shear key.
Foundation:
Foundation strength, f'c . . . .
21.0 MPa
Grout thickness . . . . . . . . .
25 mm
Rectangular, D . . . . . . . . .
450 mm
B . . . . . . . . .
300 mm
Min. bolt edge distance . . . . .
70 mm
Depth . . . . . . . . . . . . . .
1000 mm
Foundation is reinforced - reinforcement not checked.
Coefficient of friction . . . . .
0.40
MINIMUM ACTION CHECK
(Minima are based on section capacity, not member capacity.)
Specified minimum design actions:
Shear
40.0 kN
Tension
0% of Ns/ ( 1437.1) =
0.0 kN
Compression
0% of Nc/ ( 1437.1) =
0.0 kN
NOTE: Input design actions are not automatically increased if they are less than
the specified minimum actions. Minimum actions may be set in any load case.
This check warns if any design action is less than the specified minimum
for all load cases.
WARNING: Design shear force is less than specified minimum.
INPUT DESIGN
Axial, P .
Shear, Vx .
Shear, Vy .

ACTIONS
. . . . . . . . . . .
. . . . . . . . . . .
. . . . . . . . . . .

-112.2 kN
0.0 kN
0.0 kN

(comp.)

Using ASI 2011 model...


Ref. 56: Design Guide 7 - Pinned Base Plate Connections for Columns (DG7)
T.J. Hogan - ASI - 2011
ASD STRENGTH CHECKS

Strength ratio
Required strength

ASD strength

Reference

NOTE: Capacity of section is not checked.

COMPRESSION ANALYSIS
CHECK 1 - Bearing on Concrete:
Base plate area, A1 . . . . . . . 1.0080E+05 mm2
Geometrically similar area, A2 . 1.1571E+05 mm2
Concrete confinement ratio . . .
1.07
ACI318 10.17.1
Design bearing stress . . . . . .
7.7 MPa
Concrete foundation strength, Nc/ . . . .
771.1
Pass SDG1 p.14
CHECK 2 - Steel Base Plate Bending:
For I section...
a1 . . . . . . . . . . . . . .
29
a2 . . . . . . . . . . . . . .
39
a4 . . . . . . . . . . . . . .
70
a5 . . . . . . . . . . . . . .
584
k . . . . . . . . . . . . . . .
2.28
X . . . . . . . . . . . . . . .
0.11
lambda . . . . . . . . . . . .
0.381
alpha0 . . . . . . . . . . . .
38.72
Modified Thornton plate strength, Ns/ .
Pass ASI DG7 p.32
Min. thickness, tmin . . . . . .
8
SCM13 p.14-6

Pc

112.2

6.88

Pc

112.2

11.4

mm
mm
mm
mm

1279.1

mm

CHECK 3 - Weld at Column Base:


Total flange weld length . . . .
777 mm
Total web weld length . . . . . .
701 mm
Total weld length . . . . . . . .
1478 mm
NOTE: X and Y shear forces are resisted only by weld elements aligned in the
same direction as the shear force.
Column weld strength . . . . . . . . . . .
0.878 vres = 0.000 0.00
Pass
CRITICAL LIMIT STATE . . .
UTILIZATION RATIO . . . .
STRENGTH RATIO . . . . . .

Concrete foundation strength, Nc/


15%
6.876
Pass

Вам также может понравиться