From the results of Plate Load test and the attached
results, it can be seen that a small amount of settlement has been occurred due to the limited depth of influence of p l a t e u s e d . M o r e o v e r, e s t i m a t i o n / p r e d i c t i o n o f s e t t l e m e n t for design load of stone column from results depicts a settlement, which is well within the allowable settlement o f 2 5 m m . H o w e v e r, s a m e c a n b e v e r i f i e d b y d o i n g t h e zone
load
test
for
group
behavior
of
installed
stone
column.
From the load - settlement graph, constraint modulus of
installed
stone column is also
interpreted using
back
calculation and found to be more than the assumed value
in design. To c o n c l u d e , t h e c o m p r e s s i b i l i t y o f s t o n e c o l u m n i s w e l l within the stipulated allowable deformation and found to be perform satisfactorily for serviceability criteria.