Вы находитесь на странице: 1из 10

High-pressure fans

We make air work on your behalf

When the pressures on


High-pressure fans from Venti

Type HV-M

Venti high-pressure fans combine intelligent technology


with outstanding quality. They
are the first choice where safe
operation and high availability
are required alongside optimum efficiency and low energy consumption.
Venti high-pressure fans can
be used in almost limitless
ways. They are used as pressure-increase fans in industrial processing and chemical
engineering, for the fluidisation of powders, dusts and
granulates in the cement,
paint and plastics industry,
as forced-draft fans for firing
plants, as combustion air fans
in industrial furnaces, glassmelting pans and smelting
plants.

Type HV-K

Venti high-pressure fans are


compact and strongly built.
Flat performance curves permit wide variations in the flow
volume at a constant pressure increase.
Venti manufactures highpressure fans in a strong,
welded construction. The fan
scroll of the single inlet centrifugal fan is arranged in
front of the motor pedestal so
that it can be rotated, which
means the fan casing can be
positioned in 45 steps.
Light impellers make for easy
starting up, which is why we
manufacture them not only
in welded steel but also in
welded aluminium and cast
silumin, an alloy of aluminium
and silicon.

Venti balances the impeller


electrodynamically in two
planes, and arranges it in
an overhung position directly
on the motor shaft end or the
end of the drive shaft. The perfect balancing of impeller and
casing keeps noise levels low.
By loosening the mounting
plate, the impeller can easily
be inspected, fitted or removed.

Type HV-M
High-pressure fan with direct
motor drive
Drive motor: arranged on
the motor pedestal, which
is attached to the scroll.
Pressure range:
30 to 125 mbar

outstanding in every situation

Special features
Venti can fit v-belt drives to its
high-pressure fans both the
single- and the two-stage
models. The fans can be
built using heat- and acidproof materials if required.
Explosion-protection features
and gas-tight versions are also
included in the Venti range.

Type HV-ZM

Type HV-K
High-pressure fan with indirect motor drive through shaft
and coupling
Drive shaft:
mounted in two roller bearings, two bearing housing
with lubricant regulators
Coupling and motor:
flexible coupling joins shaft
and motor. Motor and two
bearing housing mounted on
a common motor pedestal.
Pressure range:
30 to 160 mbar

Type HV-ZM
High-pressure fan in the form
of a two-stage fan combination with direct motor drive
Impellers:
overhung arrangement on
the common motor shaft
Drive motor:
mounted on a common
motor pedestal between
the fan scrolls. The two
fan stages are coupled
together by a steel pipe.
Pressure range:
200 to 250 mbar

2
3

Star turn
High-pressure fans with rotatable casings

Total pressure difference pt:


30 mbar 160 mbar (at 20 C and = 1.205 kg/m)
1 mbar 100 Pa 10.2 mm WC
Dust level: max. 50 mg/m3
Motor rating
Rated speed: n = 3000 rpm, frequency: 50 Hz

1)

2)

3)
4)
5)

Impeller made from cast silumin


Impeller made from welded aluminium
Impeller made from steel

A-rated sound pressure level as per DIN 45635 with inlet and
outlet connected, under free field conditions
A-rated sound pressure level measured at a distance of 1 m at
an angle of 45 from the inlet, with outlet connected, under free
field conditions
Total weight based on three-phase motor with grey cast-iron casing
Approximate dimensions, dependent on motor manufacturer
Motor with PTC thermistor

Subject to technical revisions.

HVM/
HVK
type

Flow
volume
(m3/h)

Motor Sound pressure Weight with


output level (dB(A)) motor (kg)
(kW)
Lp1)
Lp2) M3)
K3)

Arrangement M + K
(dimensions in mm)
D
d
b
c

Arrangement M
(dimensions in mm)
f
g
h
k4)

Arrangement K
(dimensions in mm)
m
n
o
p4)

Pressure range 30 mbar 3000 Pa 300 mm WC


30- 63
30- 80
30-100
30-125
30-140
30-160
30-180
30-200
30-224

270
440
690
1000
1360
1750
2250
2750
3450

0.75
1.1
1.1
1.5
2.2
3.0
3.0
4.0
5.5

69
70
71
71
72
74
75
75
78

70
72
73
75
79
80
80
80
86

45
47
47
61
64
69
87
102
120

74
75
75
91
95
100
122
139
157

355
355
355
450
450
450
560
560
560

112
112
112
160
160
160
224
224
224

63
80
100
125
140
160
180
200
224

145
145
145
162
162
162
170
170
170

355
355
355
377
377
377
433
433
433

246
246
246
303
303
303
345
345
345

80
80
80
98
98
98
105
105
105

120
120
120
120
120
120
120
120
120

310
310
310
360
360
360
360
360
360

300
300
300
350
375
415
420
440
500

100
100
100
118
118
118
125
125
125

300
300
300
300
310
325
340
340
360

310
310
310
360
360
360
360
360
360

760
760
760
800
825
826
880
900
970

112
112
112
160
160
160
224
224
224

63
80
100
125
140
160
180
200
224

150
150
150
162
162
162
170
170
170

384
384
384
389
389
389
473
473
473

267
267
267
299
299
299
386
386
386

85
85
85
98
98
98
125
125
125

120
120
120
120
120
120
140
150
150

360
360
360
360
360
360
360
360
360

320
320
345
370
410
430
500
500
500

105
105
105
118
118
118
150
150
150

300
300
310
310
350
350
375
375
375

400
400
400
400
400
400
400
400
400

780
780
810
815
855
880
970
970
970

112
112
112
160
160
160
224
224
224

63
80
100
125
140
160
180
200
224

145
145
145
156
156
156
180
180
180

411
411
411
450
450
450
478
478
478

297
297
297
334
334
334
338
338
338

80
80
80
86
86
86
135
135
135

120
120
120
150
150
150
200
200
200

360
360
360
415
415
415
415
415
415

325
350
350
415
435
500
490
490
625

100
100
100
112
112
137
160
160
185

300
310
310
350
350
375
375
375
425

360
360
360
415
415
415
415
415
415

785
810
810
860
885
950
955
955
1100

112
112
112
160
160
160
224
224
224

63
80
100
125
140
160
180
200
224

145
145
145
162
162
162
180
180
180

443
443
443
445
445
445
520
520
520

328
328
328
346
346
346
398
398
398

80
80
80
118
118
118
135
135
135

120
120
120
150
150
150
200
200
200

415
415
415
415
415
415
460
460
460

350
350
410
430
490
490
620
620
620

100
100
125
144
144
144
185
185
185

350
350
350
350
400
400
450
450
450

415
880
415
880
415
945
415
945
415 1010
415 1010
460 1155
460 1155
460 1155

Pressure range 40 mbar 4000 Pa 400 mm WC


40- 63
40- 80
40-100
40-125
40-140
40-160
40-180
40-200
40-224

315
500
800
1000
1600
2000
2500
3000
4000

1.5 5)
1.5 5)
2.2 5)
2.2 5)
3.0
4.0
5.5
5.5
7.5

70
72
72
74
75
76
78
79
81

76
77
78
79
82
84
85
85
88

57
57
60
70
75
92
131
131
148

94
94
97
109
116
133
175
175
183

355
355
355
450
450
450
560
560
560

Pressure range 50 mbar 5000 Pa 500 mm WC


50- 63
50- 80
50-100
50-125
50-140
50-160
50-180
50-200
50-224

350
500
900
1300
1750
2250
2800
3300
4500

1.5 5)
2.2 5)
2.2 5)
3.0 5)
4.0
5.5
7.5
7.5
11.0

73
75
75
72
75
77
78
79
82

77
77
78
78
81
83
83
88
88

67
67
80
87
104
120
141
143
173

105
105
109
123
140
158
180
180
211

400
400
400
450
450
450
500
500
500

Pressure range 63 mbar 6300 Pa 630 mm WC


63- 63
63- 80
63-100
63-125
63-140
63-160
63-180
63-200
63-224

400
600
1000
1350
2000
2500
3150
3600
5000

2.2 5)
2.2 5)
4.0
4.0
5.5
7.5
11.0
11.0
15.0

73
74
76
74
76
79
81
82
85

77
79
82
85
83
84
85
85
92

77
77
82
109
125
132
192
194
205

123
123
128
154
173
180
240
242
251

450
450
450
500
500
500
560
560
560

5
for different pressure ranges

HVM/
HVK
Typ

Flow
volume
(m3/h)

Motor Sound pressure Weight with


output level (dB(A)) motor (kg)
(kW)
Lp1)
Lp2) M3)
K3)

Arrangement M + K
(dimensions in mm)
D
d
b
c

Arrangement M
(dimensions in mm)
f
g
h
k4)

Arrangement K
(dimensions in mm)
m
n
o
p4)

Pressure range 80 mbar 8000 Pa 800 mm WC


80- 63
80- 80
80-100
80-125
80-140
80-160
80-180
80-200
80-224

450
700
1150
1750
2000
2800
3500
4500
5600

3.0 5)
4.0
5.5
7.5
7.5
11.0
15.0
18.5
22.0

74
74
80
78
78
82
85
85
86

79
79
84
85
85
90
92
92
93

95
112
128
150
150
178
235
257
305

151
167
185
198
198
233
278
299
347

500
500
500
500
500
500
630
630
630

112
112
112
160
160
160
224
224
224

63
80
100
125
140
160
180
200
224

145
145
145
162
162
162
180
180
180

482
482
482
485
485
485
561
561
561

367
367
367
383
383
383
448
448
448

100
100
100
118
118
118
135
135
135

150
150
150
200
200
200
150
150
150

415
415
415
460
460
460
570
570
570

410
430
490
500
500
630
630
665
700

125
125
150
168
168
168
185
185
185

375
375
400
400
400
500
500
500
500

415
415
415
460
460
460
570
570
570

1020
1045
1100
1100
1100
1240
1250
1290
1320

112
112
112
160
160
160
224
224
224

63
80
100
125
140
160
180
200
224

145
145
145
162
162
162
180
180
180

518
518
518
528
528
528
601
601
601

411
411
411
425
425
425
482
482
482

100
100
100
118
118
118
135
135
135

150
150
150
200
200
200
175
175
175

415
415
415
460
460
460
560
560
560

490
490
490
615
615
615
665
690
780

150
150
150
168
168
168
185
185
185

425
425
425
475
475
475
475
500
500

415
415
415
460
460
460
560
560
560

1100
1100
1100
1240
1240
1240
1290
1315
1400

125
125
125
180
180
180
224
224
224

63
80
100
125
140
160
180
200
224

145
145
145
162
162
162
180
180
180

566
566
566
616
616
616
648
648
648

437
437
437
446
446
446
534
534
534

100
100
100
118
118
118

125
125
125
125
125
125

570
570
570
570
570
570
570
570
570

630
630
630
630
660
690

125
150
150
168
168
168
185
185
185

500
500
500
500
500
500
525
525
525

570
570
570
570
570
570
570
570
570

1240
1240
1240
1240
1280
1310
1400
1400
1450

500
500
500
500
500
550
550
550
600

498
498
498
498
498
498
614
614
614

1315
1315
1315
1290
1290
1400
1500
1500
1640

152
152
152
170
170
170
188
188
188

575
575
575
575
625
625
625
625
675

500
500
500
500
690
690
690
690
690

1430
1435
1485
1500
1595
1600
1630
1640
1750

Pressure range 100 mbar 10000 Pa 1000 mm WC


100- 63
100- 80
100-100
100-125
100-140
100-160
100-180
100-200
100-224

500
800
1250
2000
2300
3150
4000
4700
6300

7.5
7.5
7.5
11.0
11.0
15.0
18.5
22.0
30.0

80
80
80
81
81
84
85
87
89

84
85
85
87
87
90
92
94
96

125
141
148
192
196
207
286
332
405

181
197
204
253
253
264
328
375
448

500
500
500
560
560
560
710
710
710

Pressure range 125 mbar 12500 Pa 1250 mm WC


125- 63
125- 80
125-100
125-125
125-140
125-160
125-180
125-200
125-224

580
900
1500
2250
3000
3750
4600
5800
7400

11.0
11.0
15.0
15.0
18.5
22.0
30.0
37.0
45.0

85
85
86
87
88
89
90
91
92

86
87
89
91
93
94
95
97
99

173
201
212
232
251
297

235
264
275
295
319
371
476
476
501

560
560
560
630
630
630
710
710
710

Pressure range 140 mbar 14000 Pa 1400 mm WC equipped with start-up coupling
140- 63
140- 80
140-100
140-125
140-140
140-160
140-180
140-200
140-224

600
950
1500
1850
2350
3000
3750
4650
5800

11.0
11.0
15.0
15.0
18.5
22.0
30.0
37.0
45.0

86
87
88
88
89
90
91
92
93

87
89
91
92
93
95
96
98
99

326
326
327
330
360
420
520
521
589

650
650
650
650
650
650
650
650
650

125
125
125
180
180
180
224
224
224

63
80
100
125
140
160
180
200
224

145
145
145
162
162
162
180
180
180

629
629
629
654
654
654
679
679
679

540
540
540
520
520
520
490
490
490

Pressure range 160 mbar 16000 Pa 1600 mm WC equipped with start-up coupling
160- 63
160- 80
160-100
160-125
160-140
160-160
160-180
160-200
160-224

630
1000
1580
2500
3150
4000
5000
6300
8000

11.0
15.0
18.5
22.0
30.0
37.0
45.0
45.0
55.0

87
88
88
89
90
91
92
93
94

91
91
93
95
96
97
98
99
101

364
364
395
506
637
652
766
772
899

730
730
730
730
730
730
730
730
730

125
125
125
180
180
180
224
224
224

63
80
100
125
140
160
180
200
224

145
145
145
162
162
162
180
180
180

683
683
683
708
708
708
733
733
733

602
602
602
528
528
528
552
552
552

6
in a variety of versions

Arrangement M

Arrangement K
k4)

p4)

m
c

11.5

11.5

GL
360

GL
45

Direction of rotation
and discharge positions

GL
315

GL
90

GL
135

GR
90

GR
315

GL
270

GL
180

GR
45

GR
360

GR
270

anti-clockwise

GR
135

GR
180

clockwise
f
e

Dimensions
Inlet (D) and outlet flange (d)

Quantity g
r

d / D
(mm)

e
(mm)

f
(mm)

Quantity
g

r
(mm)

63
80
100
112
125
140
160
180
200
224

102
118
139
151
165
182
200
219
241
265

128
144
165
177
191
216
234
253
275
299

4
4
4
4
4
8
8
8
8
8

9.5
9.5
9.5
9.5
9.5
11.5
11.5
11.5
11.5
11.5

Double-barrelled performance
Two stages for maximum pressure

Arrangement ZM

14

c
s

HV-ZM

Flow
volume
(m3/h)

type

Motor Sound pressure


output level (dB(A))
(kW)
Lp1)
Lp2)

Dimensions in mm
a

76.1
88.9
114.3
139.7
168.3
168.3
219.1
219.1
273.0

955
955
955
1088
1088
1088
1160
1290
1395

518
518
518
528
528
528
601
601
601

411
411
411
425
425
425
482
482
482

255
255
255
280
280
280
325
340
370

300
300
300
350
350
350
350
400
425

440
440
440
560
560
560
600
700
760

1290
1290
1290
1415
1415
1415
1765
1765
1765

989
989
989
1049
1049
1049
1219
1219
1219

1360
1360
1360
1565
1565
1565
1860
1990
2095

76.1
88.9
114.3
139.7
168.3
168.3
219.1

1065
1065
1065
1088
1132
1262
1405

566
566
566
616
616
616
648

437
437
437
446
446
446
534

260
260
260
280
305
320
340

350
350
350
350
350
400
450

560
560
560
560
600
700
760

1400
1400
1400
1570
1570
1570
1890

1084
1084
1084
1178
1178
1178
1318

1470
1470
1470
1565
1610
1740
2085

Pressure range 200 mbar 20000 Pa 2000 mm WC


Impeller made of steel
200- 63
200- 80
200-100
200-125
200-140
200-160
200-180
200-200
200-224

500
800
1250
2000
2300
3150
4000
4700
6300

18.5
18.5
18.5
30.0
30.0
37.0
45.0
55.0
75.0

85
87
89
90
91
92
93
94
95

88
90
92
95
96
97
99
100
102

500
500
500
560
560
560
630
630
630

139.7
139.7
139.7
168.3
168.3
168.3
273.0
273.0
273.0

Pressure range 250 mbar 25000 Pa 2500 mm WC


Impeller made of steel
250- 63
250- 80
250-100
250-125
250-140
250-160
250-180

580
900
1500
2250
3000
3600
4600

30.0
30.0
30.0
37.0
45.0
55.0
75.0

87
89
91
93
94
95
96

90
93
95
98
99
100
102

560
560
560
630
630
630
710

139.7
139.7
139.7
168.3
168.3
168.3
273.0

Flange for connection on inlet and outlet side


as per DIN 2641 Series 1 ND6

Direction of rotation and discharge position of the second stage

GL
360

GL
45

Quantity g

GR
90

d
/

GR
315

GL
315

GL
90

GR
45

GR
360

GL
135
anti-clockwise

GL
180

GL
270

GR
270
clockwise

GR
180

GR
135
e
f

d / D
(mm)

e
(mm)

f
(mm)

Quantity
g

r
(mm)

76.1
88.9
114.3
139.7
168.3
219.1
273.0

130
150
170
200
225
280
335

160
190
210
240
265
320
375

4
4
4
8
8
8
12

14
18
18
18
18
18
18

Precision-fitting effectiveness
The ideal accessories for high-pressure fans

Venti customises its highpressure fans for each situation, and can fit them with
the following components:
Securable throttle valves
for mounting on the outlet
side
Splitter, pipe and disc
silencers
Acoustic enclosures for
reducing noise levels
by up to 25 dB
Inlet filters
Flexible joints and
vibration dampers for
isolated mounting

Vibration dampers

Flexible joints

The dynamic forces transmitted into the foundation can be


reduced by installing vibration
dampers, whose design and
distribution depend on the
type of fan involved.

Venti provides flexible joints


for the inlet and outlet side
fan connection. The material
used for the flexible joint
depends on the demands of
what is being conveyed, and
is usually neoprene, silicon
glass or PVC polyester.

Inlet filter

Pstat (Pa)

Flange dimensions
to fit the fans inlet connector

Pressure loss

Pressure loss from inlet filter


in relation to flow volume

400
300
200
100

V (m 3 /h)

0
0
0
0
0

200
400
700
1000
1400

400
800
1400
2000
2800

600
1200
2100
3000
4200

800
1600
2800
4000
5600

Filter no.
1,3
2,4,5
6,8,10,11
7,9,12
13

Filter
no.

D
(mm)

A
(mm)

L
(mm)

1
2
3
4
5
6
7
8
9
10
11
12
13

112
112
125
125
160
160
160
180
180
200
224
224
224

240
360
240
360
360
360
500
360
500
360
360
500
500

210
260
210
260
260
460
460
460
460
460
460
460
660

1000
2000
3500
5000
7000

Working on the quiet


Effective sound insulation for a good working environment

Acoustic enclosures for high-pressure fans


Noise reduction is legally
mandatory and improves
working conditions, which is
why we recommend the use
of acoustic enclosures. They
effectively absorb the sound
energy radiated by the fan.

Absorption silencer with casing

Venti acoustic enclosures


comprise several easy-toassemble wall and roof
sections. There is an access
opening, either a door or a
flap depending on the size of
the enclosure, to allow easy
access for fan maintenance.

Our splitter silencers are


specially designed for you
on the basis of the specifications you require, and reduce
the pressure only slightly (the
amount depends on the specifications).

Construction of
insulating walls
Acoustic enclosures in conjunction with splitter silencers
are the ideal way of reducing
the sound pressure level.

Perforated plate

Loose
mineral fibre

Abrasion-proof mineral fibre plate


Anti-drone lining

Insertion attenuation value


of the acoustic enclosure
according to VDI 2711

Lp 35
(dB)
30

The graph indicates the


acoustic insulation value of
the acoustic enclosure across
the entire frequency range.

Attenuation value De, K

25
20
15
10
5
63

125

250

500 1000 2000 4000 8000


f
(Hz)

Outer plate

If the fan is a free-inlet fan,


then the acoustic enclosure
is normally force-ventilated.
In the case of more powerful
motors, or if the inlet pipe
leads out of the enclosure,
then additional ventilation is
required in the form of an
axial flow fan built into the
wall of the enclosure.
Venti also offers simple casing insulation for situations
requiring less noise insulation.

8
9

D 1/ 02 / 15 / 3.Stu
Subject to alterations

Industrial fans
Dust collection and process air cleaning plants
Exhaust air treatment plants
Ventilating, heating and air conditioning plants
Recycling and waste processing plants
Surface technology

Ventilatorenfabrik Oelde GmbH


P.O. Box 37 09
D-59286 Oelde
Phone: +49 25 22 75 - 0
Fax:
+49 25 22 75 - 2 50
info@venti-oelde.de
www.venti-oelde.de

Вам также может понравиться