Вы находитесь на странице: 1из 11

Block C

14701
13801

Block C
Grease Points

Metering Units

15
16
17
18

no.4
no.4
no.4
no.4

Boom slide pads


Boom slide pads
Boom slide pads
Boom slide pads

0.20cc
0.20cc
0.20cc
0.20cc

Linde 357

Block TL-A

Block TL-A
Grease Points

Metering Units

19
20
21
22
23
24
25
26
27
28
29
30

no.2
no.2
no.8
no.8
no.2
no.2
no.4
no.4
no.4
no.4
no.2
no.2

Tilt cylinder
Tilt cylinder
Pivot point
Pivot point
Tilt cylinder
Tilt cylinder
Rotating table
Rotating table
Rotating table
Rotating table
Side shift cylinder
Side shift cylinder

0.10cc
0.10cc
0.40cc
0.40cc
0.10cc
0.10cc
0.20cc
0.20cc
0.20cc
0.20cc
0.10cc
0.10cc

Block TL-A
Material List
Centre Top of Spreader
Description
12-port block
No.8 metering unit

Part no.
072.01
017.01

Qty
1
2

No.4 metering unit

013.01

No.2 metering unit


011.01
Bracket
GUK151
Elbow male 1/8 x 3/16
102.01
Adaptor 1/8
086.08
Male conn 1/8 x 3/16
104.01
Screw
126020
12mm Clamp
013.08
Screw
027.01
Cable tie
002.08
Cable tie
111.07
Conduit
140.08
Pipe
022.08
Washer
09202
Adaptor
A101-04-06
Bonded washer
80004

6
1
10
2
2
2
13
13
75
50
25
30
2
2
2

Linde 357

27 28

19 20

25

26

23 24
21 22

29
30

Block TL-A
Linde 357

Block TL-B
Block TL-B
Grease Points

Metering Units

31
32

no.2
no.2

Side shift cylinder


Side shift cylinder

0.10cc
0.10cc

31

32

Linde 357

Block TL-C
Block TL-B

Material List

Description
2-port industrial block
No.2 metering unit
Ground plate
Male elbow 1/8 x 3/16
Screw
Washer
Pipe
T-piece
Adaptor
Bonded washer
Elbow

Top of Spreader

Part no.
Qty
186.22
1
011.01
2
110.02
1
102.01
2
126027
2
09202
2
022.11
2
A191-06
1
A101-04-06 2
800404
2
A115-06
1

Block TL-C
2-port industrial block
Ground plate
Blanking plug (block)
Blanking plug (m/unit)
Screw
Washer
T-piece
Straight conn
Bonded washer

186.22
110.02
442.01
009.01
126027
09202
A192-06
A101-04-06
800404

1
1
1
2
2
2
1
1
1

Linde 357

Block TL-D
Blocks TL-D &TL-E
Grease Points

Metering Units

33
34
35
36
37
38
39
40

no.2
no.2
no.2
no.2
no.2
no.2
no.2
no.2

Twist Lock
Twist Lock
Twist Lock
Twist Lock
Twist Lock
Twist Lock
Twist Lock
Twist Lock

0.10cc
0.10cc
0.10cc
0.10cc
0.10cc
0.10cc
0.10cc
0.10cc

Linde 357

Block TL-E

Blocks TL-D & TL-E Material List


Description
4-port industrial block
No.2 metering unit
Male conn 1/8 x 3/16
90 degree adaptor (1/8 x 1/8)
Blanking plug
Ground plate
Screw
Washer
Conduit
Cable ties
90degree elbow
Straight conn 9/16x9/16

End of Spreader

Part no.

Qty (each block)

104.02
011.01
104.01
150.01
442.01
110.02
126027
092.02
GUK124
002.08
4-4C4OMLO
4-HMLO

1
4
4
2
2
1
2
2
2
15
2
2
Linde 357

Linde 317 - 356 - 357 - 358

Groeneveld Automatic Greasing System


Service Information

1)

In-Cab Warning lights


Green
Flashing Red Constant Red -

2)

System on 5-minute greasing cycle


(80 bar minimum pressure)
Low grease level
Low / no pressure in system
(check pump pressure gauge reading)

Electronic Timer
a)

Adjusting cycle time interval


The interval time between two successive greasing cycles can be
adjusted using the step switch. One of ten intervals can be selected (15
min to 150 min in 15 min increments). If the ignition is switched off
during the greasing cycle, that cycle will be ended. When the ignition is
switched on again greasing will resume at the next set time.

b)

Testing the timer


The various electronic timer positions can be tested as follows:
(N.B. 356/357 have "power on" red led on timer box.)
Test 1, Step switch test
- Set the switch to position test A.
- Activate the timer by switching on the ignition.
- Press the Red test button.
- Wait for the in-cab Red warning light to activate, then release the
test button.
- Within 2 seconds turn the step switch to the required time position.
Each position produces a signal: position 1 (15 min) gives one flash,
position 2 (30 min) gives two flashes, etc.
- The switch can be set to all positions but note positions test A and
test B will produce a flashing Red alarm signal.
- N.B. "Test B" position is not used.
- End the test by switching off the ignition.
Test 2, Single cycle
In order to check the system, a single lubrication cycle can be
performed.
- Switch the ignition on Press the Red test button on the electronic
time, for at least 3 seconds, a normal greasing cycle will then follow.
The switch can be set in any position except test A and test B.
After this the timer will operate at the set i nterval.

Test 3, Accelerated (multi) Cycle


- Switch ignition on
- Set the step switch to position test A
- Press and hold the test button.
- The Red warning light in the cab will now light up. The test button
must be pressed as long as the light is on.
- Within 3 seconds of the Red light going off turn the step switch to
the 15 minute cycle position.
- The timer is now fully operational, the time intervals are now 1/20 of
their usual times. The pressure gauge on the pump should indicate
a minimum of 80 bar per cycle.
- End the test by switching the ignition off.
Reset timer to normal factory setting - 75 mins or a setting to suit
end user operating conditions.
3)

To bleed system
a)
b)
c)
d)
e)
f)
g)

4)

Remove distribution block blanking plugs.


Switch ignition on.
Press and hold the Red test button for at least 5 seconds. This will
activate one full 5 minute greasing cycle.
Repeating above procedure (b and c) until grease appears with no air
bubbles.
Replace distribution block blanking plugs.
Check pump pressure gauge shows 100 bar (+/-10 bar).
Reset timer to appropriate intervals.

Grease Specification Groeneveld ZW-O


a)

NLGI Class

0 (zero)

b)

Thickener

Lithium / Calcium

c)

Drop point, Din 1502176

170?C

d)

Water resistant, Din 51807, Part

1:90

e)

Temperature range

-20?C to +110?C

f)

Base oil viscosity at 40?C (min..mm2/5) -

Mineral oil polymer 700

g)

Protection against corrosion


(In accordance with Emcor test) Din 51802
Application
-

0 and 0

h)

Earth moving /